Bulletin 1492 Programmable Controller Wiring Systems Overview. Digital Interface Modules (IFMs) Feed-Through
|
|
- Ralf Dean
- 5 years ago
- Views:
Transcription
1 Bulletin Overview Digital Interface Modules (IFMs) Feed-Through Feed-through IFMs provided the same capability as normal terminal blocks, but in a more condensed package. Feed-through Standard For -point: Cat. No. -IFMF For -point: Cat. No. -IFMF Feed-through Extra Terminal Products For -point: Cat. No. -IFMF- For -point: Cat. No. -IFMF- Feed-Through Narrow Cat. No.-IFMFN Feed-through Sensor Terminal Products For -point: Cat. No. -IFMF- For -point: Cat. No. -IFMF- Safety Integrity Level (SIL ) Cat. No. -TIFMF-F- -
2 Bulletin Overview Digital Interface Modules (IFMs) Fusible Fusible modules provide a convenient method of adding overcurrent protections into your programmable controller wiring. These modules have x fuse holders on-board and are available with and without blown fuse indication. The V, V, and V blown fuse indicators reduce the troubleshooting time to locate and replace a blown fuse on the IFM. Fusible modules have an easy-to-remove, transparent plexiglass cover that prevents objects from contacting fuse circuitry under normal operation. Removal of fuses from the standard fuse holder is aided by fuse pullers (fuses not provided). The fusible modules also have two or four terminals per I/O point to create a power bus for input and output load connections. Fusible modules are available in both isolated (Cat. No. -IFMF-FS-) and nonisolated (Cat. No.- IFMF-F-) versions. There are a select number of fusible IFMs available for input modules.provided). The fusible modules also have two or four terminals per I/O point to create a power bus for input and output load connections. Fusible modules are available in both isolated (Cat. No. -IFMF-FS-) and nonisolated (Cat. No.-IFMF-F-) versions. There are a select number of fusible IFMs available for input modules. Fused Extra Terminals For -point: Cat. No. -IFMFS-F-, -IFMFS-FA-, -IFMFS-F- For -point: Cat. No. -IFMFS-F-, -IFMFS-FA-, -IFMFS-F-, -IFMFS-FA-, -IFMFS-F-, -IFMF-FSA- Fused Extra Terminals For -point: Cat. No. -IFMF-F-,-IFMF-F-, -IFMF-FA-, -IFMF-F-, -IFMF-FA-, -IFMF-F-, -IFMFS-F -, -IFMFS-F-, -IFMFS-FA- For -point: Cat. No. -IFMF-F-, -IFMF-F-, -IFMF-F-, -IFMFS-F-, -IFMFS-F-, -IFMFS-F-, -IFMFS-F-, -IFMFS-FA-, -IFMFS-F-, -IFMFS-FA-, -IFMFS-F- -pin cable connector Isolated Fusible module (no fuse blown indication): Cat. No. -IFMF-FS- -pin cable connector Isolated Fusible module with V blown fuse indication: Cat. No. -IFMF-FSA- Safety Integrity Level (SIL) Cat. No. -TIFMF-FA- -
3 Bulletin Bulletin ControlLogix Modules Digital IFMs and Cables for Bulletin ControlLogix -point Isolated and -point I/O Modules [V]... per I/O -IAI -IBD -IBI -IA Bulletin ControlLogix I/O Module Feed-through Standard -IFMF -RIFMF -RTB Y Y Y Z Z Z Y Y Y Y Y Y Z Z Y Y Y Extra Terminals -IFMF- -RIFMF- -RTB Y Z Z Z Y Z Z Sensor -IFMF- Z Z Indicating Standard -IFMD -RIFMD -RTB Z Z Z Z Extr. -IFMD- Z Z Extr. -IFMDA- -RIFMDA- -RTB Z Z Sensor -IFMD- Z Z Isolated -IFMDS- Y Y Y Y Y Y Isolated Extr. -IFMDSA- Y Y -IFMDA- Z Isolated -IFMDS- Y Y Y Isolated Isolated Extra Terminals -IFMDSA- Y -IFMDSA- Y Fusible -IFMF-F- -RIFMF-F- -RTB Z Z -IFMF-FD- Y -IFMF-FAD- Y -IFMF-F- Z Z Fusible - Isolated Extr. -IFMF-FS- Y Y Y Y Y -IFMF-FS- Y Y Y Y Y -IFMF-FSA- Y Extr. -IFMF-FS- Y Y Y Y Y Y Y Y Extr. -IFMF-FS- Y Y Y Y Y Y Y See footnotes on the following page. -IFMF-FSA- Y Y Y Y -IFMF-FS- -RIFMF-FS- -RTB Y Y Y Y -IFMF-FS- -RIFMF-FS- -RTB Y Y Y -IFMF-FSA- -RIFMF-FSA- -RTB Y Y -IFMF-FS- Y Y Y -IFMF-FSA- Y Safety Integrity Level (SIL) -TIFMF-FA- Z Z -TIFMF-- Y -IB -IV -IHI -IMI -OAI -OBEI -OBD -OBI -OBIS -OB -OVE -OHI -OWI -OXI -
4 Bulletin Bulletin CompactLogix Modules Digital IFMs and Cables for Bulletin CompactLogix -point I/O Expansion Modules Bulletin CompactLogix I/O Module [V]... per I/O RTB Plugs Cat. No. Cat. No. Cat. No. Feed-Through -IQ -IQT -OB -OBT Digital Cable Cat. No. Suffix Standard -IFMF -RIFMF -RTB J H K H H Extr. -IFMF- -RIFMF- -RTB J H K H H Sensor -IFMF- J H Indicating Standard -IFMD -RIFMD -RTB J H K H H Extr. (output) -IFMD- K H H Extr. -IFMDA- -RIFMDA- -RTB J H Sensor -IFMD- J H Extr. -IFMF-F- -RIFMF-F- -RTB K H H... Extr. -IFMF-F- K H H -OVT See footnotes on the following page. -
5 Bulletin Bulletin and MicroLogix Modules Digital IFMs and Cables for Bulletin MicroLogix I/O Bulletin MicroLogix I/O Module [V] per I/O Feed-Through Standard -IFMF -RIFMF A A A B B B -RTB Extr. -IFMF- -RIFMF- A A A B B B To order a Pre-wired Cable, add the Suffix No. from the table above to the end of the Cat. No. below..m Cable = -CAB_.M Cable = -CAB_.M Cable = -CAB_.M Cable = -CAB_ Custom Length Cable = -CABXXX_. See Catalog Number Explanation on page - for available Custom Length Codes to replace XXX in Cat. No. Order plugs separately (two plugs per catalog number). Plugs are available in screw style and push in style terminal types. To order, replace the in the catalog number with the code for the desired terminal style. The code for screw style is N and the code for push in style is P. When using this IFM module with the base I/O of the controller, the current rating of the outputs must be considered. Refer to Publication -TD for details. Digital IFMs and Cables for Bulletin MicroLogix I/O [V] per I/O -LAWA Inputs -LBWA Inputs -LBXB Inputs -LAWA Outputs -LBWA Outputs -LBXB Outputs Bulletin MicroLogix I/O Module Feed-Through Narrow -IFMFN -RIFMFN -RTB A A B C C F Standard -IFMF -RIFMF -RTB A A B C C F Extr. -IFMF- -RIFMF- -RTB A A B C C F To order a Pre-wired Cable, add the Suffix No. from the table above to the end of the Cat. No. below..m Cable = -CAB_.M Cable = -CAB_.M Cable = -CAB_.M Cable = -CAB_ Custom Length Cable = -CABXXX_. See Catalog Number Explanation on page - for available Custom Length Codes to replace XXX in Cat. No. Order plugs separately (two plugs per catalog number). Plugs are available in screw style and push in style terminal types. To order, replace the in the catalog number with the code for the desired terminal style. The code for screw style is N and the code for push in style is P. When using this IFM module with the base I/O of the controller, the current rating of the outputs must be considered. Refer to Publication -TD for details. -AWA Inputs -BWA Inputs -BXB Inputs -AWA Outputs -BWA Outputs -BXB Outputs -
6 Bulletin Bulletin Flex I/O Modules Digital IFMs and Cables for Bulletin Flex I/O -Point and -Point Modules [V]... per I/O -IB -IB Bulletin Flex Digital I/ Module Feed-Through Standard -IFMF -RIFMF -RTB A A A A A A A A A A A Narrow -IFMFN -RIFMFN -RTB A A A A A A A A A A A Extr. -IFMF- -RIFMF- -RTB A A A A A A A A A A A Sensor -IFMF- A A A Indicating Standard -IFMD A A A A A A Narrow -IFMDN A A A A A A Extr. (output) -IFMD- A A A A A A Extr. -IFMDA- A A A... Isolated w/ Extr. Isolated w/ Extr. -IFMDS- A -IFMDS- A Fusible Blown Fuse -IFMF-F- -RIFMF-F- -RTB A A A A A A Blown Fuse -IFMF-FA- -RIFMF-FA- -RTB A A Blown Fuse -IFMF-F- -RIFMF-F- -RTB A A A A A A Fusible, Isolated Blown Fuse -IFMF-FS- A... Extr. (output) -IFMF-FS- A Blown Fuse -IFMF-FS- A Digital IFMs and Cables for Bulletin Flex I/O -Point and -Point Modules -IBXOB -IV -OB -OBP -OB -OBEP -OV -OVP -OW Bulletin Flex Digital I/O Module [V]... per I/IO -IBD - IBXOBP Feed-Through Standard -IFMF -RIFMF -RTB B B B B Extr. -IFMF- -RIFMF- -RTB B B B B Indicating Standard -IFMD -RIFMD -RTB B B Extr. (output) -IFMD- B Extr. -IFMDA- -RIFMDA- -RTB B Extr. Blown Fuse Fusible -IFMF-F- -RIFMF-F- -RTB B... Extr. (output) -IFMF-F- B To order a Pre-wired Cable, add the Suffix No. from the table above to the end of the Cat. No. below..m Cable = -CAB_.M Cable = -CAB_.M Cable = -CAB_.M Cable = -CAB_ Custom Length Cable = -CABXXX_. See Catalog Number Explanation on page - for available Custom Length Codes to replace XXX in Cat. No. Order plugs separately (two plugs per catalog number). Plugs are available in screw style and push in style terminal types. To order, replace the in the catalog number with the code for the desired terminal style. The code for screw style is N and the code for push in style is P. Uses D-Shell Base -TBDS Uses D-Shell Base -TBDS -IB -OBP -
7 Bulletin Digital Cables I/O Ready Digital Cables I/O-Ready for Bulletin ControlLogix Cable Cat. No. Cable Cat. No. Standard Cable Lengths -CABLE TBNH.,.,. m Yes -CABLE TBCH.,.,. m Yes Standard Cable Lengths Build-to-Order Available No. of Conductors Mating I/O Module Cat. No. -CAB RTN.,.,. m Yes -OA, -OW, -OB -CAB RTN.,.,. m Yes -IAI, -IA, -IQ, IQF, -OA, -OB, -OV, -OW, -OWI, -IM, -OW, -B -CAB RTNI.,.,. m Yes -IQ -CAB RTNO.,.,. m Yes -OB -CABLE N.,.,. m Yes -IQT, -OBT, -OVT Cables are available in standard lengths of.,., and. m. To order, insert the code for the desired cable length into the cat. no. ( =. m, =. m, and =. m). Example: Cat. No. -CABRTN is for a. m cable with a wired Cat. No. -RTBN on one end. Use # AWG wire. Discrete I/O ready cables should not be used with PLC analog I/O modules as a cable shield and drain wire are not provided. Cable Cat. No. Standard Cable Lengths Build-to-Order Available No. of Conductors Mating Controller I/O Cable Cat. No. -CAB P.,.,. m No -OBT and -OVT Output Expansion I/O -CAB U.,.,. m No -IQT Input Expansion I/O -CAB T.,.,. m Yes -LAWA Outputs, -LBWA Outputs, -LBXB Outputs -CAB X.,.,. m Yes -LAWA Inputs, -LBWA Inputs, -LBXB Inputs I/O ready cables are available in standard lengths of.,., and. m. To order, insert the code for the desired cable length into the cat. no. ( =. m, =. m, and =. m). Example: Cat. No. -CABT is for a. m cable that could be used to connect a catalog number -IFMF to a catalog number -LAWA Input. Cable Cat. No. Standard Cable Lengths Build-to-Order Available No. of Conductors Mating Base I/O Cat. No. -CAB T.,.,. m Yes AWA Outputs, BWA Outputs -CAB U.,.,. m Yes BXB Outputs -CAB W.,.,. m Yes AWA Inputs, BWA Inputs -CAB X.,.,. m Yes BXB Inputs I/O ready cables are available in standard lengths of.,., and. m. To order, insert the code for the desired cable length into the cat. no. ( =. m, =. m, and =. m). Example: Cat. No. -CABT is for a. m cable that could be used to connect a catalog number -IFMF to a catalog number -AWA Input. Uses # AWG wire. Uses # AWG wire. Standard Cable Lengths Build-to-Order Available No. of Conductors Mating I/O Module Cat. No. -IAD, -IA, -IB, -IC, -IN, -IV, -OA, -OAD, -OAE, - OA, -OB, -OBE, -OC, -ON, -OVE -IAI, -IA, -IBD, -IBI, -IB, -IV, -IHI, -IMI, -OAI, -OBEI, -OBD, -OBIS, -OBI, -OB, -OVE,-OHI, -OWI, -OXI Cables are available in standard lengths of. m,. m, and. m. To order, insert the code for the desired cable length into the cat. no. ( =. m, =. m, and =. m). Example: Cat. No. -CABLETBNH is for a. m cable with a pre-wired Cat. No. -TBNH RTB on one end. Discrete I/O read cables should not be used with PLC analog I/O modules as cable shield and drain wires are not provided. Digital Cables - I/O-Ready for Bulletin CompactLogix Digital Cables I/O-Ready for Bulletin MicroLogix Digital Cables I/O-Ready for Bulletin MicroLogix Digital Cables I/O-Ready for Bulletin Flex I/O Build-to-Order Available No. of Conductors Mating I/O Module Cat. No. -CAB G.,.,. m Yes -IB, -IB, -IV, -OB, -OBP, -OB, -OBEP, -OV, OVP, - OW, -IBXOB -CAB H.,.,. m Yes -IBD, -IB, OBP, -IBXOBP Cables are available in standard lengths of.,., and. m. To order, insert the code for the desired cable length into the cat. no. ( =. m, =. m, and =. m). Example: Cat. No. -CABG is for a. m cable. Not available for Analog I/O Modules -
8 Bulletin Specifications Digital IFM Specifications - Digital IFM Cat. No. Range Dimensions (W x H x D) [in.] Indicator Circuit Current (Nominal) [ma] Label Card Cat. No. -IFMF, -RIFMF V AC/DC. x. x. --, -- -IFMFN, -RIFMFN V AC/DC. x. x. --, --, -- -IFMF-, -RIFMF- V AC/DC. x. x. --, --, -- -IFMF- V AC/DC. x. x. -- -IFMD V AC/DC. x. x. --, -- -IFMDN V AC/DC. x. x. --, --, -- -IFMD- V AC/DC. x. x. --, --, -- -IFMDA- V AC/DC. x. x. -- -IFMDS- V AC/DC. x. x IFMD- V AC/DC. x. x. --, -- -IFMD V AC/DC. x. x.. --, -- -IFMDN V AC. x. x.. --, --, -- -IFMD- V AC. x. x.. --, -- -IFMDA- V AC. x. x IFMDS- V AC. x. x IFMD- V AC. x. x.. --, -- -IFMDA- V AC. x. x IFMF-F-, -RIFMF-F- V AC/DC. x. x. --, --, -- -IFMF-F-, -RIFMF-F- V AC/DC. x. x. --, --, -- -IFMF-FA-, -RIFMF-FA- V AC/DC. x. x.. --, -- -IFMF-F-, -RIFMF-F- V AC. x. x.. --, --, -- -IFMF-FA-, -RIFMF-FA- V AC/DC. x. x.. --, -- -IFMF-F- V AC. x. x.. --, -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FSA- V AC/DC. x. x IFMF-FS- V AC/DC. x. x IFMF-FS- V AC/DC. x. x IFMF-FSA- V AC/DC. x. x IFMF-FS- V AC. x. x IFMF, -RIFMF V AC/DC. x. x. --, --, -- -IFMF- V AC/DC. x. x. --, --, --, --, -- -RIFMF- V AC/DC. x. x. --, --, --, --, -- -IFMF- V AC/DC. x. x. --, -- -IFMD, -RIFMD V AC/DC. x. x. --, --, -- -IFMD- V AC/DC. x. x. --, --, -- -IFMDA- V AC/DC. x. x. --, --, --, --, -- -RIFMDA- V AC/DC. x. x. --, --, --, --, -- -IFMDS- V AC/DC. x. x IFMDSA- V AC/DC. x. x IFMD- V AC/DC. x. x. --, -- -IFMD- V AC. x. x.. --, --, -- -IFMDA- V AC. x. x.. --, --, - -IFMDS- V AC. x. x IFMDSA- V AC. x. x IFMDSA- V AC. x. x IFMF-F- V AC/DC. x. x. --, --, -- -IFMF-F- V AC/DC. x. x. --, --, --, --, - -RIFMF-F- V AC/DC. x. x. --, --, --, --, - -IFMF-FD- V AC/DC. x. x. <. -- -IFMF-FAD- V AC/DC. x. x. <. -- -IFMF-F- V AC. x. x.. --, --, -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x IFMF-FS-, -RIFMF-FS- V AC/DC. x. x IFMF-FS- V AC/DC. x. x RIFMF-FS- V AC/DC. x. x IFMF-FS- V AC/DC. x. x IFMF-FSA- V AC/DC. x. x IFMF-FSA- V AC/DC. x. x RIFMF-FSA- V AC/DC. x. x IFMF-FSA- V AC/DC. x. x. -- -IFMF-FSA- V AC/DC. x. x TIFMF-F- V DC. x. x. -- -TIFMF-FA- V DC. x. x. -- To convert to millimeters, multiply inches by. Ships with each module. For spare part, precede the part number with the letter "W." Add. in. to the width dimension for Bulletin -Rxxx modules.
A-B Compatible Interface Modules. Connect with CAGE CLAMP
AB Compatible Interface Modules Connect with CAGE CLAMP Interface Modules for AllenBradley PLC Platforms Connect with CAGE CLAMP Wiring systems for PLC I/O cards have been reducing wiring time, eliminating
More information1492 ACABLE 050 A. A-Cable Type TA, TB, TC, TD, UA, UB, UC, UD, VA, VB, WA, WB, X, Y, Z, ZA, ZB, ZC 1492 ACAB 005 A46. Cable Type
Digital/Analog Programmable Controller and PowerFlex Drive Wiring Systems Pre-Wired Cable Catalog Number Explanation for Bulletins,, and Analog I/O Modules Important: The following analog cable catalog
More informationTerminal Blocks/Wiring Systems/Signal Conditioners Table of Contents
Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates
More informationKinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationKinetix 300 Single-axis Servo Drives
Installation Instructions Kinetix 300 Single-axis Servo Drives Catalog Numbers 2097-V31PR0, 2097-V31PR2, 2097-V32PR0, 2097-V32PR2, 2097-V32PR4, 2097-V33PR1, 2097-V33PR3, 2097-V33PR5, 2097-V33PR6, 2097-V34PR3,
More informationTerminal Blocks/Wiring Systems/Signal Conditioners Table of Contents
Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates
More informationTerminal Blocks/Wiring Systems/Signal Conditioners Table of Contents
Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates
More informationCompact Circuit Protector (CCP)
Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationTechnical Data. PowerFlex 700H Adjustable Frequency AC Drive
Technical Data PowerFlex 700H Adjustable Frequency AC Drive Table of Contents Topic Page Product Overview.............................................. 3 Key Features and Benefits.......................................
More information16-Channel Digital Output Termination Card Introduced Power 24Vdc
TDO16AIN 16-Channel Digital Output Termination Card Introduced Power 24Vdc (TDO16AIN) Issue 6 October 2005 INTRODUCTION PURPOSE The TDO16AIN 16-channel digital output termination card acts as an interface
More informationwww. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide
Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand
More informationKinetix 350 Single-axis EtherNet/IP Servo Drives
Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,
More informationSMI SERIES MOTORS WITH INTEGRATED INVERTER
SERIES MOTORS WITH INTEGRATED INVERTER Series series is made up of three-phase asynchronous electric motors with integrated frequency inverter.power range is between 0,37 kw and 4 kw, while motor axis
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationCompact Circuit Protector (CCP)
Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description
More informationCompact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm
Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationTPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family
TPM Fuse Panel Installation Guide Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...
More informationSolenoid Valve Output Module IC693MDL760 Product Description
GFK-A November 000 Solenoid Valve Output Module ICMDL0 Product Description Description This ICMDL0 output module provides eleven pneumatic outputs and five VDC sourcing outputs. For each pneumatic output,
More informationCompact Circuit Protector
Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available
More informationPower Distribution System User s Manual. Model: PDS-100
Power Distribution System User s Manual Model: PDS-0 Section Page Product Overview... 1 I) General Information... 2 II) Important Safety Information... 2 III) Installation... 3 A) Materials Provided...
More informationDiscrete Output Modules IC697MDL753
52 1 I97MDL753 (I97MDL753) datasheet Features 32 Points - Two isolated groups of 16 points each a44141 0.5 amp capacity per point High inrush capacity (10x rated current) Functions The 5/48 Volt DC 0.5
More informationBulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks
Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method
More information1492-CB 1492-GH 1492-GS
1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic
More informationTerminal Blocks/Wiring Systems/Signal Conditioners Table of Contents
Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates
More informationPRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES
PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial
More informationLow Profile DC Power Supply with Zero Voltage Soft Switching
Sorensen XFR Series Low Profile DC Power Supply with Zero Voltage Soft Switching Analog programming Zero voltage soft switching Constant voltage or constant current operation with automatic crossover and
More informationTPM/GMT Panel Installation Guide
TPM/GMT Panel Installation Guide Document INS-837xxxxxxx This manual covers the following part numbers- Trimm 837xxxxxxx Family Table of Contents Table of Contents... 2 Section 1- General Information...
More information600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:
Issue Date: 07/17/2017 Page: 1 of 5 PSS- K656LR Elbow Connector (with Test ) Applications: The Elastimold K656LR (with test point) is designed to provide fully shielded, dead-front submersible cable connections
More informationType C Track Circuit Uninterruptable Power Supply
Safetran Systems Instruction & Maintenance Model CXP-3 Type C Track Circuit Uninterruptable Power Supply Instruction & Maintenance Type C Track Circuit Uninterruptable Power Supply Contents Introduction...2
More informationFUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified
0521-03A May 2006 FUSE PANEL Technical Practice FDP 1010 10/10 GMT NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 10 GMT fuses in each (15Amps/GMT position) Polarity insensitive (+/-24 or
More informationKEPCO Will Point You In The Right Direction!
Looking For A High Power, Low Profile Power Supply? KEPCO Will Point You In The Right Direction! -9 AN ISO 900 COMPANY You'll Always Find What You Need At Kepco KLN Series Programmable Power Supply: 0W
More informationBulletin 1497A Machine Tool Transformers
Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed
More informationPower Controller. (see note 1) 10 sec
Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control
More informationFUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified
530-101732 Rev L 0223-03K September 30, 2010 Westell FUSE PANEL Technical Practice N250140-N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 20 GMT fuses each (15Amps/GMT
More informationSorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V. Power mit System
Sorensen XG Series / XTR Series 670 850 W 850 W, 1U Half Rack Programmable DC Power Supplies 6 600 V 1.4 110 A 110 220 The Sorensen XG Series and the Sorensen XTR Series are the same 850 Watt, 1U half-rack
More informationSUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More informationVariable Frequency AC Motor Drive Units
14 Variable Frequency A Motor Drive Units ulletin 2162T and 2163T PowerFlex 40 Drive................................................. 171 These combination variable frequency A motor drive units are specifically
More informationBulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism
Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationNoran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified
0322-03D Sept 02, 2010 Noran Tel FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 5 GMT fuses each (20Amps/GMT position). Polarity
More informationModel Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend
Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start
More informationOperation and Maintenance manual. fusible shunt trip switch
Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse
More informationCompact Circuit Protector
Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and
More informationThe ISF003 is a range of overmoulded 0603 or smaller surface mounted fuses nominally sized 5.6 mm (L) x
ISF001, ISF003, ISF004 and ISF005-50 C to +93 C (I N = 2 A max) -50 C to +80 C (I N = 3 A max) These fuses either bear no marking or carry a colour code and/or alphanumeric coding that is defined in an
More informationSorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V
Sorensen XG Series / XTR Series 670 850 W 850 W, 1U Half Rack Programmable DC Power Supplies 6 600 V Highest Power Density Comprehensive Digital and Analog Interface Options Scalable, Multi-Unit Design
More informationBUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses
Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationTOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)
TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29132-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the
More informationACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers
www.murata-ps.com Now Available with Wire Lead CTs FEATURES for direct measurement of 0 to 2/20/50/100 Amps Functionally complete: On-board current transformers Scaling/interface circuitry Precision A/D
More informationALTIVAR FLEX58 Chassis Drive Controller Product Selection
ALTIVAR FLEX58 Chassis Drive Controller Product Selection Class 8806 CONTENTS Description Page General Information and Selection....................................... 2 Specifications and Ratings...........................................
More informationCapacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality
Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power
More informationSeries L9 UL489 Miniature Circuit Breakers
Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded
More informationMini Vehicle Controller (MVC)
Mini Vehicle Controller (MVC) Mini Vehicle Controller (MVC) The MCC Mini Vehicle Controller (MVC) was developed to meet the demanding requirements of the mass transit and off-road market. The MVC was designed
More information8W-97 POWER DISTRIBUTION - SERVICE INFORMATION
HB 8W-97 POWER DISTRIBUTION - SERVICE INFORMATION 8W - 97-1 8W-97 POWER DISTRIBUTION - SERVICE INFORMATION TABLE OF CONTENTS page POWER DISTRIBUTION - SERVICE INFORMATION...1...1 SPECIAL TOOLS POWER DISTRIBUTION
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery
More informationGMT Fuse Panel Installation Guide
GMT Fuse Panel Installation Guide Document INS-707XXXXXXX This manual covers the following part numbers- Trimm 707XXXXXXX Family Table of Contents Section 1- General Information... 3 1.1 - Product Description...
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationLiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible
LiteMinder Fast Transfer System 1.0 to 18.75KVA LED Compatible Series Inverter Pure Sine Wave Modular Inverter Technology Modular AC System Evenlite s LiteMinder Central Inverter System provides an innovative
More information1395 Digital DC Drive Renewal Parts
Important Information, Read First 1395 Digital DC Drive Page 1 of 19 The 1395 Product Line has evolved from current rated units to horsepower rated units. Within the range of sizes there are various series
More informationTOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)
TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user
More informationPHOENIX CONTACT
Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers
More informationCables for Relay Blocks
9 Cables for Connect Economical with Controllers from Omron and Other Manufacturers 1 General-purpose cables connect relay blocks to any manufacturer s controllers 1 Dedicated cables for Omron s highdensity
More informationACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers
www.murata-ps.com Now Available with Wire Lead CTs C US E156931 FEATURES for direct measurement of 0 to 2/20/50/100 Amps Functionally complete: On-board current transformers Scaling/interface circuitry
More informationBulletin 1497A Machine Tool Transformers
Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed
More informationFUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified
530-063 Rev K 0220-03K November 3, 202 Westell FUSE PANEL Technical Practice N25020-N-L33 0/0 GMT Front Access NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 0 GMT fuses in each (5Amps/GMT
More informationC1 Y-Cable. Overview. Features. Power Weight Temperature Humidity Dimensions
C Y-Cable Overview The C Y-Cable is Rhythm Engineering s custom connection between a 70/2070 traffic controller and the InSync Processor. Using the C Y-Cable makes for fast, easy, error-free installation
More informationINTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:
INTELLITROL Overfill Prevention Control Unit with Optional Ground Verification and Vehicle Identification Features. Scully s Intellitrol System is the most advanced terminal overfill prevention and ground
More informationDATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island incl. SMA ENERGY METER
3PHBatteryBackupDistribution for 1x Sunny Island incl. SMA ENERGY METER enwitecordernumber 10012550 Customerarticlenumber Type designation Match code Application Batteryinverter ENERGY METER Grid structure
More informationSuppression Technology Valve Suppressors - special function
Energy reducer, design A (18 mm), PUR cable Energy reduction approx. 50 %, protection device, LED status indication 0 180 field installation, open cable end Energy reducer Length of connecting lead (M)
More informationThis Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.
This Datasheet for the IC670MDL90 2A 8 Pt. 6 form A/2 form C Isolated http://www.qualitrol.com/shop/p-142-ic670mdl90.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control
More informationSineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING
SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationBR Second Position Voltages. AA Fourth Position
1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V
More informationFlex Amplifiers Installation Instructions
Flex Amplifiers Installation Instructions Introduction This publication describes the installation procedure for the 4100U and 4100ES Flex Amplifiers. This product is compatible with both 4100U and 4100ES
More informationDIN Rail Power Module
800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A www.lutron.com +44.(0)20.7702.0657 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller DIN Rail odule The DIN Rail odule family
More informationSWB505 MultiMount EN1090
SWB505 MultiMount EN90 Right the First Time Safe, Accurate, Service Friendly Tank Weighing SWB505 MultiMount weigh modules offer rugged construction and many features for easy installation and accurate
More informationCHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)
Supersedes August 2016 BUSSMANN SERIES Specifications: 2011/65/EU Volts 600 V (or less) UL 690 V (or less) IEC 1000 Vdc (or less) photovoltaic (PV) Amps 30 A UL 32 A IEC Short-Circuit Current Rating (SCCR)
More informationDART. Operation / Installation Manual. Digital Analog Remote Transducer. Computer Weld Technology, Inc. Manual Part Number: A8M5015 Revised: 9/28/2004
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com DART Digital Analog Remote Transducer Operation / Installation
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationOrder No. of the options EMC filter Class A
Ordering Data for Variant Dependent Options The options listed here (filters, chokes, brake resistors, gland plates, fuses and circuit breakers) are inverter specific. The inverter and the associated options
More informationIB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC
IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC Inline Power Terminal With Fuse and Diagnostics Data Sheet 5569C 02/2003 # # $ ' ) The IB IL 24 PWR IN/F-D and IB IL 24 PWR IN/F-D-PAC only differ in the scope
More informationKelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.
Kelly HSR Opto-Isolated Series Motor Controller with Regen User s Manual HSR72601 HSR72801 HSR12401 HSR12601 HSR12901 HSR14301 HSR14501 HSR14701 Rev.3.3 Dec. 2011 Contents Chapter 1 Introduction... 2 1.1
More informationDaikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015
Replacement Parts List No. 700050700 Revision A 12/2015 Daikin McQuay Vertical Stack Water Source Heat Pump WVHC, WVHF, WVHW 036 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationUnity Low Voltage Disconnect & Monitor
Unity Low Voltage Disconnect & Monitor Installation/Operation Manual Model: ULM-100 Table of Contents Page Table of Contents Page 1.0 Overview 2 5.14 LVD Level Mapping 4 2.0 Materials Provided 2 5.2 Meter
More information0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)
Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and
More informationAllen Bradley Panelview Plus 600 Manual
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with allen bradley panelview
More information1489-M Circuit Breakers
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable
More informationSWC515 PinMount. Right the First Time Safe, Accurate, Service Friendly. SWC515 PinMount. Right the First Time
SWC515 PinMount Right the First Time Safe, Accurate, Service Friendly Tank Weighing SWC515 PinMount weigh modules offer rugged construction and many features for easy installation and accurate and reliable
More informationPROTECTION OF THE BRANCH CIRCUIT
PROTECTION OF THE BRANCH CIRCUIT Branch circuit should always be protected from over current. Hence, an overall current devices shall be installed in all branch circuitries. Function of the over-current
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationSWB505 MultiMount. SWB605 PowerMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time
SWB505 MultiMount SWB605 PowerMount Right the First Time Safe, Accurate, Service Friendly Tank Weighing SWB505 MultiMount / SWB605 PowerMount weigh modules offer rugged construction and many features for
More informationARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI
II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,
More informationQuik-Spec Coordination Panelboard Specifications
Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY
More informationCertificate Record Certified Product Listing CSA Group
Page 1 of 20 HOME ABOUT SERVICES INDUSTRIES SHOP CSA LOG IN Home Services Testing & Certification Certified Product Listing Certificate Record Certificate Record Customer Class File Number Marquardt GmbH
More informationBulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks
Bulleting IEC Terminal Blocks Overview and Regulatory Information Bulletin -J, -W -L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks Technology Screw terminations are a time-proven method
More informationAnalog Input Terminal
Analog Input Terminal I/O Interface Converts Analog Input Data into Binary Data Four inputs available. High resolution of 1/6000. Conversion is possible within a range of 5% to 105% FS. High conversion
More information