DIN Rail Power Module
|
|
- Pauline Banks
- 6 years ago
- Views:
Transcription
1 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A (0) DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller DIN Rail odule The DIN Rail odule family is a group of modular products for the control of lighting loads. This document describes the following product: DIN Rail odule Phase Adaptive (model ) Features DIN Rail odules can be used in a omeworksr QS system. Automatically selects leading edge or trailing edge dimming for incandescent/halogen, electronic/magnetic low voltage and neon/cold cathode light sources. Controls dimmable CF/ED loads, contact utronr for compatibility with CF/ED light sources. RTISSR technology ensures that each output dims smoothly and is flicker-free. Unit is 12 DIN modules (216 mm) wide. 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A (0) DIN Rail odule b Provides air gap off (when all zones are off). Integral protection for common temporary overcurrent and over-voltage conditions. EDs on front of unit provide diagnostic information. Includes QS link for seamless integration of lights and controls. System Example Contact Closure seetouchr QS Wallstation DIN Rail odule omeworksr QS Panel QS Contact Closure Interface GRAFIK EyeR QS QS ink Up to 100 total QS devices DIN Rail odule Phase Adaptive DIN Rail odule V~ Control { 4 Phase Adaptive outputs, 800 W (Zone 1) 1, 500 W (Zones 2, 3 and 4) 1 Notes: 1 See "Output Zone Ratings" in "Specifications" section, for specific load types ratings. odel Numbers:
2 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller Out of Box Functionality This section describes the default functionality when the unit is first installed b Emergency Contact Closure () When the is open, the DIN Rail odule will enter Emergency ode, which will turn on all loads to their emergency level and disable control of local zones and QS devices. When the is closed or jumpered, DIN Rail odule zones will return to the settings or levels they were at prior to entering Emergency ode. is local control only and cannot control other DIN Rail odule over the QS link. on multiple DIN Rail odule may be connected to an Emergency or anual override device in parallel if event is intended to affect multiple units. Emergency level is configurable for each zone. Normal ode Operation Zone and raise/lower buttons on the unit can be used to: turn loads on and off. dim loads up and down. odel Numbers:
3 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller Specifications DIN Rail odule V~ 50/60 z ightning strike protection meets ANSI/IEEE standard Can withstand voltage surges of up to V and current surges of up to A. Standards IEC/EN CE marked utronr Quality Systems registered to ISO Environment Ambient Temperature Operating Range (inside mounting panel within 2 cm of unit): 0 ºC to 35 ºC Calibration point maximum: 70 ºC (see ounting on page 4) Relative humidity: less than 90% non-condensing For indoor use only Terminals ains wiring: 1.2 N m mm² (solid or stranded) Zone wiring: 1.2 N m mm² (solid or stranded) wiring: 0.5 N m mm² (solid or stranded) QS ink: 0.5 N m mm² (solid or stranded) b Output Zone Ratings Automatically selects leading edge or trailing edge dimming or can also be manually configured for a specific load type. Patented RTISSR circuitry compensates in real time for incoming line frequency variations: up to ± 2% change in frequency/second. Internal relay provides an air gap off when all zones are off. Each zone has no minimum load requirement. Each zone is rated for the following load types 1, 2 : oad Type Zone 1 Zone 2, 3 and 4 Rating Rating (per zone) Incandescent/alogen 800 W 500 W Electronic ow Voltage 800 W 500 W agnetic ow Voltage 800 VA (600 W 3 ) 500 VA (375 W 3 ) Neon/Cold Cathode 800 VA (600 W 3 ) 500 VA (375 W 3 ) 1 Additional load type options are available in the omeworksr QS GUI, some may require an interface. Contact utron for details. 2 Contact utron for compatibility with dimmable CF/ED light sources. 3 Actual lamp wattage One load type per zone. Output must be directly connected to the load. oad side switching is not recommended. Run a separate neutral for each load circuit. A common neutral connection is not recommended. Unit may be powered by Ground Fault Interrupter (GFI) or Residual Current Circuit Breaker with Overload (RCBO) protected circuit if required. oad circuit wiring (from breaker to unit to load) must be run in its own non-metallic conduit, or nuisance tripping may occur. aximum 30.5 m (100 ft) between power module and load. ounting Use an IP20 (minimum) rated consumer panel or breaker panel with integrated DIN rail. Unit is 12 DIN modules (216 mm) wide. odel Numbers:
4 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller ounting b ount in IP20 (minimum) rated consumer panel or breaker panel with integrated DIN rail. ount unit in orientation shown. Unit may be mounted by unlocking the four mounting clips on the back of the unit. Clips must be locked once unit to securely attached the unit to the DIN rail. ount in an accessible and serviceable location. Unit generates heat, maximum 75 BTUs/our ount unit such that: Ambient Temperature Operating Range (inside mounting panel within 2 cm of unit): 0 ºC to 35 ºC -Calibration point maximum: 70 ºC - Derate unit or cool mounting panel as needed to maintain the above temperature requirements. 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A (0) DIN Rail odule ocked 4 mounting clips on unit Unlocked echanical Dimensions Top View 800 W ax 500 W ax 500 W ax 500 W ax i Temp DIN Rail odule 90 mm 230 V~ 50 / 60 z 10 A (0) Side View 216 mm 70 mm 76 mm 55 mm 90 mm odel Numbers:
5 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller Overview of Wiring Terminals b Contact Closure QS ink 800 W ax 500 W ax 500 W ax 500 W ax i Temp DIN Rail odule 230 V~ 50 / 60 z 10 A (0) N N N N N D1 D2 D3 D4 ains oad Neutrals Zone 1 Zone 3 ains Wiring Zone 2 Zone 4 Phase Adaptive Outputs odel Numbers:
6 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller Bypass Jumper b Unit ships with bypass jumper pre-installed. Jumper should not be removed until load wiring is verified. 800 W ax 500 W ax 500 W ax 500 W ax i Temp DIN Rail odule 230 V~ 50 / 60 z 10 A (0) N N N N N D1 D2 D3 D4 Bypass Jumper odel Numbers:
7 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller ains Voltage Wiring b W ax 500 W ax 500 W ax 500 W ax i Temp 800 W ax 500 W ax 500 W ax 500 W ax 230 V~ 50 / 60 z 10 A (0) DIN Rail odule r p DIN Rail odule Zone 1 Example 50 / 60 z 10 A (0) N N N N N D1 D2 D3 D4 Distribution Panel Earth ive Neutral Dim ive ( V~) Neutral oad Wiring from Distribution to DIN Rail odule Turn off all circuit breakers or isolators feeding the DIN Rail odule at distribution panel. Run live, neutral, and earth( ) wires from a V~ 50/60 z feed to the DIN Rail odule unit. Run a separate neutral for each load circuit. A common neutral connection is not recommended. ains Wiring and IEC PEV Separation Follow appropriate local and national codes to avoid violating required separation guidelines. odel Numbers:
8 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller Wiring: Emergency Contact Closure 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A (0) DIN Rail odule Common b IEC PEV Emergency Contact Closure Contact Closure () wiring is IEC PEV. Follow all applicable national and local codes for proper circuit separation and protection. Turn off all breakers or isolators feeding the DIN Rail odule at distribution panel before servicing unit. When in emergency mode, all zone outputs will be at their programmed emergency light level (configurable to each zone, default is 100%). All sensors and controls are locked out. Emergency contact closure input is normally closed (NC). The DIN Rail odule is shipped with a jumper pre-installed. Note: The DIN Rail odule will default to Emergency ode if the is left open. If no Emergency Contact Closure is required, please leave the wire jumper in the terminals. CO 800 W ax 500 W ax 500 W ax 500 W ax (0) odel Numbers:
9 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller Wiring: QS ink 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A (0) DIN Rail odule QS ink IEC PEV Wiring b ink communicates using IEC PEV wiring. Turn off all breakers or isolators feeding the DIN Rail odule at distribution panel before servicing unit. Follow all applicable national and local codes for proper circuit separation and protection. Wiring may be daisy chained or t-tapped. Total length of QS link must not exceed 600 m. For lengths under 150 m, use two 1,0 mm 2 conductors for control power (24 V-, CO). For lengths over 150 m, use two 4,0 mm 2 conductors for control power (24 V-, CO). Use one, twisted-shielded pair of 1,0 mm 2 conductors for data link (UX, _). 0 W ax (1) CO one 4 (2) Do Not Connect Teminal 2 1 (3) UX (4) UX Daisy-Chain Wiring Example seetouchr QS wallstations QSE-IO T-Tap Wiring Example seetouchr QS wallstations QSE-IO 1 Unit does not consume or supply PDUs on the QS link. Do not connect the 24 V- wire to unit. Note: 24 V- wire must bypass the unit if other devices on the link consume PDUs. odel Numbers:
Adaptive Power Module
N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive
More informationAdaptive Power Module
N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive
More informationDIN Power Module - Phase Adaptive
DI Power Module ow Capacity Phase Adaptive DI Power Module - Phase Adaptive 369849d 1 07.29.16 The Phase Adaptive Power Module family is a group of modular products for the control of lighting loads. This
More informationGP Dimming Panels 230 Volt (CE)
30 Volt (CE).3.08 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim. Models available with:
More informationGP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL
rev gp-a 7.0.00 GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available
More informationLP Dimming Panels. GRAFIK Systems
GAFIK Systems lp-1 12.8.03 are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Work directly with incandescent, magnetic low voltage,
More informationPhase-Adaptive Power Module with 3-Wire Fluorescent Input
369-358c 1 03.19.12 Description When connected to a 20 A circuit breaker, provides capacity on a 3-wire fluorescent dimmer for a full 16 A load of lighting. May be used to dim incandescent, halogen, electronic
More informationPhase-Adaptive Power Module
Phase-Adaptive Power Module Provides dimming control for 1 zone of a full 16 A lighting load. May be used to dim incandescent, halogen, electronic low-voltage, magnetic low-voltage, neon/cold cathode.
More informationGP Dimming Panels 230 Volt (CE)
GAFIK Systems 30 Volt (CE) gp- 03.0.04 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim.
More informationLCP128T Spec Grade Dimming System
LCP128T Spec Grade Dimming System 369-642a 1 06.04.12 System Overview LCP128T is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels
More informationPhase-Adaptive Power Module
GAFIK Eye papm-1 3.12.08 Description Provides capability for a zone on a GAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic
More informationSwitching Power Module
369357d 1 06.20.13 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic
More information3-Wire Fluorescent Power Module
369355 Rev B 1 09.02.11 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to dim fluorescent lights that have Lutron Hi-lumeR and Eco-10R (Eco Series) line-voltage
More informationEcoSystemT 5-Series LED Driver ( V~, CE)
EcoSystemT 5-Series LED Driver (220-240 V~, CE) EcoSystemT 5-Series LED Drivers provide a high performance solution for any space in any application, while providing smooth, continuous dimming down to
More informationQS Motor Group Controller QSE-CI-4M-D 4-Output AC Motor Controller. Energi Savr NodeTM Unit. seetouchr QS Wallstation. Wireless Communication
LUTRON LUTRON R Motor Grop Controller E-CI-4M-D 4-Otpt AC Motor Controller Motor Grop Controller The motor grop controller is an interface that provides seamless integration of Qantm and stand-alone systems
More informationHi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming
Hi-lume LED Overview Hi-lume LED 1 12.11.9 Hi-lume LED is a high-performance, constant current driver that provides energy-efficient dimming for LED lighting. With industry-leading full-range % to 1% dimming,
More informationInstallation & User Instructions
Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.
More informationSeries L9 UL489 Miniature Circuit Breakers
Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded
More informationWired Vareo Local Lighting Controls
Wired Vareo Local Lighting Controls 8 Series Local Lighting Controls D48 Bus Architectural-Style L o c a l l i g h t i n g c o n t r o l s Wired Vareo local lighting controls function much like standard
More informationEcosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 EC3DT4MWKU1S 26/32W T4 1LMP Ba Lutron Catalog Number Manufacturer Description Weight per unit Product Category EC3DT4MWKU1S
More informationAXA DALI P20. DALI Broadcast Controller. Installation Manual
AXA DALI P20 DALI Broadcast Controller Installation Manual THE DALI P20 MUST BE INSTALLED BY A LICENSED ELECTRICIAN IMPORTANT INFORMATION ELECTRICIANS MUST READ PRIOR TO INSTALLATION 1) This product must
More informationEcoSystemR Multiple Control Input Ballasts
EcoR Multiple Control s 369454h 1 09.15.14 Digital electronic dimming ballasts maximize the benefits of a lighting management system. EcoR s offer 100% to 10% dimming; ideal for use where saving energy,
More informationDSE201 Compact design with enhanced protection
DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)
More informationIndustry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Power Switching Introduction CRESTRON GREEN LIGHT power switching cabinets come pre-configured with GLXP modules already installed. The cabinets only require installation and wiring of feed and load circuits.
More informationEcoSystem Multiple Control Input Ballasts
Eco Five Control Digital Dimming s Eco Multiple Control s 369454l 1 09.02.16 Digital electronic dimming ballasts maximize the benefits of a lighting management system. Eco s offer 100% to 10% dimming;
More informationSpring-Return Damper Actuator NF24(-S)
Spring-eturn Damper Actuator NF24(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control: Open/Close Integrated auxiliary switch NF24-S Technical
More informationNEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.
www.usa.siemens.com/controls NEA Pump Controls Class 82 slim line NEA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEA Pump Controller Typical applications include:
More informationFeatures. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More information4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals
IO Input/Output Modules IO-ABM4 Analogue Override Module Description IO-ABM4 Analogue Override Module Intended for applications which require independent manual override of analogue output channels from
More informationINSTALLATION. **Microprocessor Status LED:
INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East Orem, Utah 84097 Telephone 801 229 2800 Fax 801 224 0355 Standard Dimmer Module MODEL: SDM12-EM Overview The SDM12 dimmer module
More informationDifferential Temperature Controller
3 337 Synco 100 Differential emperature Controller R27 Differential temperature controller for solar storage systems. Compact design with two 2-position control output AC 24 230 V. Use Plant types: Solar
More informationElectric Actuator Instructions
BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5
More informationCompact SE Overview. High-Performance Dimming. Ballast
Compact SE Overview CompactSE 01.10.10 For designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your solution.
More informationThermal overload relays Type TA Class 10
Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate
More informationApplication Note #466 Revision I May 2018
ounting Guidelines for utron DIN Rail Products Revision I ay 2018 English A DIN rail is a metal rail widely used for mounting circuit breakers and industrial control equipment inside enclosures. The term
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationFDBT S 32W120V DM Bal
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-794 ax: 936-560-4685 llenwatson@elliottelectric.com DT430S 3W0V DM al Catalog Number Manufacturer Description Weight per unit Product Category
More informationUser Manual Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More informationSeries L9 UL-489 Miniature Circuit Breakers
Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada
More informationELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS
HVAC/BAC ELECTRIC IOM ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS Electric Actuator Specifications... 2 Overview... 3 Actuator
More informationBasic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors
MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided
More informationConstant Voltage TRIAC Dimmable Driver---120W Series. Features
Features Specification Output constant voltage Universal AC input: 90-130VAC.Power Factor:up to 0.95 High Efficiency: up to 84% Protections: short circuit / over loading / over current Full protection
More informationMVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam
Document No. 125-4361 VF461H Series odulating Control Valves with agnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam Description Control valves with magnetic actuators,
More informationELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS
ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS 94OE IOM Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4
More informationCircuit Protection. Circiut Protection
Circuit Protection Series L8 UL1077 Supplementary Protectors...2 Selection Guide - Trip Curve "B"...4 Selection Guide - Trip Curve "C"...5 Selection Guide - Trip Curve "D"...6 Accessories...7 Technical
More informationWired Maestro Local Controls
Wired Maestro Local Controls 4 Series / 8 Series Local Controls H48 Bus Designer-Style L O C A L c o n t r o l s Wired Maestro local controls function much like standard dimmers and switches, but can be
More informationA.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual
Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323
More informationEcoSystem Multiple Control Input Ballasts
Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More information825-P Modular Protection System for motors Specification Guide
Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationProduct Data Sheet. Damper Interface. Features
Damper Interface Product Data Sheet Features Damper Motor drive and limit switch monitoring integrated into a single unit Dual limit switch inputs for confirmation of damper-fully-open and damperfully-closed
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationElectronic Circuit Breaker ESS20
Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode
More informationPneumatic Isolation Module
Pneumatic Isolation Module (Cat. 2030-Pxxxxx) ATTENTION: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: Prior to beginning the installation and wiring process,
More informationHomeWorks QS Power Supply with Wire Harnesses
HomeWorks QS ower Supply with Wire Harnesses The HomeWorks QS ower Supply provides power to the HomeWorks QS processor as well as system devices and interfaces. Featuring easy assembly on a DIN rail, the
More informationBtdin RCBO 6000A up to 63A (2P)
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-
More informationFluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.
Installation Instructions Please Leave for Occupant HP-2, HP-4, & HP-6 Dimming Module 120/277VAC, 60Hz Description Dimming Module HP-2 2000W/VA 16A@120/277V 60Hz Listed Industrial Equipment 243C Dimming
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationGRX-TVI Ten Volt Interface
Lutron Power Interfaces Ten Volt Interface 36947d 07.07.4 Features 00-77 V~ forward, reverse, and center phase control input capability Provides control and switching capabilities to switch and dim current
More informationZurik EMLV LED Driver
White Zurik EMV Dimmable Driver (Phase Dimming) For Forward Phase, MV, Reverse Phase, and EV Model: ZRK-EMV-120-24VDC : 100-130V~ 2A 50/60 Hz λ: 0.65 : 24V 5A COFORMS TO U STD.1012 CERTIFIED TO CSA STD.C22.2
More informationDIN Rail UPS Model: DIN-UPS Installation/Operation Manual
DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information
More informationSafety Control HR1S-AC. Safety Relay HR1S-AC
HRS-AC Safety Relay HRS-AC Key features: NC or 2NC safety input type, such as E-Stops or Interlock Switches EN ISO 3849- PLe, Safety Cat 3 compliant, and EN 6206 SIL 3 Fault diagnosis function with dual
More informationOTEC Transfer switch open transition
Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator
More informationSentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification
543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication
More informationControls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES
SPECIFICATION SUBMITTAL s The contractor s choice in rugged, linear slide dimmers. www.lutron.com/nova CONTROLS AND ACCESSORIES Slide-to-Off s Preset s Select light level with slider; slide down to off
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationDemarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide
Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08 Installation Guide Table of Contents 1.1 Overview... 2 1.2 Specifications... 3 1.3 Inspection... 3 1.4 Installation... 4 1.4.1 Important Installation
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationEcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module
Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron bus supplies (Eco-10 and Hi-lume
More informationCOMPLETE SOLUTIONS FOR POWER PROTECTION
COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX
More informationGRX-TVI Ten Volt Interface
Lutron Power Interfaces Ten Volt Interface 369247c 1 09.17.13 Features 100-277 V~ forward, reverse, and center phase control input capability Provides 0-10 V- control and switching capabilities to switch
More informationCompact SE Overview. High-Performance Dimming. Ballast
allast Compact SE Overview CompactSE- 03.08.04 or designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your
More informationPower Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies
Standard Series Standard Series Switching Part Numbers Part Number Item Watts Rated Voltage Rated Current -A V DC 1.A -A 7. V DC.6A -A24 24V DC.3A -B V DC 2.A Key features of the standard series include:
More informationFL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC
PC BASIC, 4 28 W PC BASIC Product description CELMA Energy Efficiency Index A2 / A3 Nominal life-time up to 50,000 h (at max. ta with a failure rate max. 0.2 % per 1,000 h) Large temperature range (for
More informationLED Driver Linear / area fixed output
Driver LC 65W 4-7mA flexc lp ANCED series Product description Built-in constant current LED Driver Adjustable output current between 4 and 7 ma Max. output power 65 W Up to 94 % efficiency Nominal life-time
More informationZone Selective Interlocking
Application Paper AP02602002EN Supersedes 08/2003 Zone Selective Interlocking Contents Description.... Page What is Zone Selective Interlocking?... 3 What is the purpose of Zone Selective Interlocking?....3
More informationModels. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery
AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit
More informationMotor Controllers AC Semiconductor Motor Controller Type RSHP Flexy
otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral
More informationFL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC
T8 c PC BASIC sl, 4 28 W PC BASIC Product description CELMA Energy Efficiency Index A2 / A3 Nominal life-time up to 50,000 h (at max. ta with a failure rate max. 0.2 % per 1,000 h) Large temperature range
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationQUALITY ASSURANCE & DOCUMENTATION
QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationDIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual
DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided
More informationNEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.
Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high
More informationCat N 3. OVERALL DIMENSIONS
Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationFT-10 Network Digital I/O Module Kits and
Instruction Sheet 10-2004 FT-10 Network Digital I/O Module Kits 541 0771 and 541 0772 PURPOSE OF KIT The Digital I/O Module (DIM) makes provisions for a group of relay contact outputs and discrete inputs
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More informationTransfer switch OTEC and OTECSE open transition
Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More information1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED
Art. no.: 1711DE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationAPC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply
APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous
More information