Spring-Return Damper Actuator NF24(-S)

Size: px
Start display at page:

Download "Spring-Return Damper Actuator NF24(-S)"

Transcription

1 Spring-eturn Damper Actuator NF24(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control: Open/Close Integrated auxiliary switch NF24-S Technical data Electrical data Nominal voltage 5/6Hz, Nominal voltage range AC 9..8, DC 2..8V Power consumption running / holding Wire/transformer sizing Auxiliary switch NF24-S 8VA 2 SPDT, 6(3)A, AC 25V Switching points, 85 Connection - otor Cable m, 2x.75mm 2 - Auxiliary switches NF24-S Cable m, 6x.75mm 2 Functional data Torque - otor - Spring min. nominal voltage min. 7Nm Direction of rotation Selectable by mounting / Angle of rotation ax. 95 (35...% adjustable by mechanical limiter) unning time Sound power level otor < 75s, spring return < 3s (Temp = 2 C) otor max. 55dB(A), Spring return approximately 62dB(A) Position indicationl echanical Protection class III (safety extra-low volatage) Service life > 6, full cycles Working conditions Degree of protection IP54 in any directions EC CE according to 89/336/EEC Dimensions / weight Ambient temperature Non-operation temperature Humidity test aintenance Dimension ( x W x H) Weight C C 95%H, non condensing (EN673- aintenance-free 248x98x97.5mm Approximately 3g Dimensions [mm]

2 Spring-eturn Damper Actuator NF24-S For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control signal: DC 2()...V Position feedback: DC 2...V Technical data Electrical data Functional data Nominal voltage Nominal supply range Power consumption Wire/transformer sizing Connection cable Torque - otor - Spring Control signal Feedback signal Working conditions Direction of rotation Angle of rotation unning time Sound power level Position indication Service life Protection class Degree of protection Selectable by mounting / ax. 95 ( 35...% adjustable by rotation limiter) otor 5s, spring return <3s approximately (Temp=2 C) otor max. 55dB(A), Spring max. 62dB(A) echanical > 6, full cycles III (safety extra-low voltage) IP54 in any directions Dimensions / weight EC Ambient temperature Non-operation temperature Humidity test aintenance Dimensions ( x W x H) Weight 5/6Hz, AC 9..8V, DC 2..6V running / holding 6VA Cable m, 4x.75mm 2 min. nominal voltage min. 7Nm DC 2()...V (input impedance k ) DC 2...V CE according to 89/336/EEC,92/3/EEC,93/68/EEC C C 95%H, non condensing (EN673- aintenance-free 248 x 98 x 97.5mm Approximately 3g Dimensions [mm]

3 Spring-eturn Damper Actuator NF23(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC 23V Control: Open/Close Integrated auxiliary switch (NF23-S) Technical data Electrical data Nominal voltage AC 23V 5/6Hz Nominal voltage range Power consumption Wire/transformer sizing AC V 7VA Connection cable - otor Cable m, 2x.75mm 2 - Auxiliary switches NF23-S Cable m, 6x.75mm 2 Functional data Torque - otor - Spring min. nominal voltage min. 7Nm Direction of rotation Selectable by mounting / Angle of rotation unning time Sound power level ax. 95 (35...% adjustable by rotation limiter) otor <75s, spring return <3s (Temp=2 C) otor max. 55dB(A), Spring approximately 62dB(A) Position indication echanical Service life > 6, full cycles Working conditions Degree of protection IP54 in any directions Dimensions / weight Auxiliary switch NF23-S Switching points EC ow Voltage Directice Protection class Ambient temperature range Non-operation temperature Humidity test aintenance Dimensions ( x W x H) Weight running / holding 2 SPDT, 6(3)A, AC 25V, 85 CE according to 89/336EEC CE according to 73/23/EEC II (totally insulated) C C 95%H, non condensing (EN673- aintenance-free 248x 98 x 97.5mm Approximately 3g Dimensions [mm]

4 Wiring diagrams Spring-eturn Wiring diagram: Open/Close actuators Notes: Parallel connection of several actuators is possible. Power consumption must be observed. AC 23V (for AF23..) S S2 S3 S4 S5 S6 % B = % AF23-S, AF24-S AF24, AF23 N AC 23V (for AF23..) N AC 23V (for NF23..) To isolate from the main power supply, the system must incorporate a device which disconnects the phase conductors ( at least a 3mm contact gap). 2 S S2 S3 2 S S2 S3 S4 S5 S6 > S < S S =..9 % AF23-S, AF24-S < < 85 NF23-S,NF24-S AF23, AF24 NF23, NF24 N AC.V (for TF23..) N AC 23V (for F23..) 2 S S2 S3 2 S S2 S3 > x < x x =...% TF23-S, TF24-S > x < x x =...% F23-S, F24-S TF23, TF24 F23, F24 5

5 Wiring diagrams Spring-eturn Wiring diagram: 3-Point actuators Notes: Connection via safety. Parallel connection of several actuators is possible. Power consumption must be observed. ~ T ounting side eversing switch a b a (Y b (Y 2) stop stop stop stop Y Y 2 TF24-3 ounting side eversing switch a b (Y ) (Y 2 ) stop stop stop stop ~ T F24-3 5

6 Wiring diagrams Spring-eturn Wiring diagram: odulating actuators Notes: Connection via safety. Parallel connection of several actuators is possible. Power consumption must be observed. ounting side Y DC 2()...V U DC 2...V eversing switch F24-S, AF24-S, AF24-S Y DC 2()...V U DC 2...V NF24-S easuring voltage U for position indicating or as master-slave control signal. For minimum position and override control consult manufacturers' literature ounting side eversing switch T + ~ ounting side Y U DC 2() V DC 2 V eversing switch 52 TF24-S

7 Auxiliary switch adjustment Auxiliary switch adjustment for Non-Spring-eturn Actuators. Press the push button, manually operate the universal clamp to desired switch position. 2. Turn switch pointer to the middle line. S2 S S3 S2 S3 S 3. When actuator moves clockwise (counterclockwise) to switch position, switch indicator passes the middle line counterclockwise (clockwise), the contact between S and S3 is disconnected (connected) and the contact between S and S2 is connected (disconnected). Note: The switching point should be about 5 from the mechanical end stops ( short step on the scale). 2 Auxiliary switch adjustment for Spring-eturn Actuators F..-S (ounting side ) Starting point: Actuator in safe position Procedure Turn the knob of the auxiliary switch until the tip of the arrow is pointing to the required switching position (see right). Example: Switching point setting = corresponds to 4% angle of rotation. When the actuator runs to the operating position (ccw ), the switch knob will also rotate counter-clockwise (ccw ) and the auxiliary switch will operate as the tip of the arrow passes the scale zero (S S3 linked). S2 S3 S S2 S3 S Fast unning Q.. Actuators operating controls and indicators 53

8 Electrical accessories Actuators CU U NU SU GU TF F NF AF AF S..A.. Auxiliary switch, add-on SA.. SPDT 3A (.5A), AC 25V S2A.. 2 SPDT 3A (.5A), AC 25V P..A.. Feedback potentiometer, add-on P4A.. 4Ω P5A.. 5Ω PA.. Ω P28A.. 28Ω P5A.. 5Ω PA.. Ω SGA24 Positioner for surface mounting...% eversible operating range DC...V or DC 2...V SG24 Positioner for surface mounting...% eversible operating range DC...V or DC 2...V SGE24 Positioner for rack mounting...% eversible operating range DC...V or DC 2...V SGF24 Positioner for front-panel mounting...% eversible operating range DC...V or DC 2...V ZAD24 Digital position indicator for front-panel mounting...99% Front size 72x72mm Operating range DC 2...V 2) 2) 2) 2) For...-S 2) For.-S 54

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0. LMU24(S/F/) For operation of air control dampers in HVAC system orque: 5Nm Nominal voltage: AC/DC 24V Control: Open/Close or 3point echnical data Electrical data Functional data Working conditions Nominal

More information

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return. Actuators for heating, ventilation, air conditioning 2. F-2 -CD Product Information Damper actuators with spring return F i6772 Contents Selection table orque 4 Nm F24 F24-S F23 F23-S F24-3 F24-S Nominal

More information

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i Actuators for heating, ventilation, air-conditioning. LM-4 -CD Product Information Damper actuators LM i689 he complete range of damper actuators for general use in HVAC systems ype LM NM SM AM GM LF AF

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Non-Spring Return SMU... series

Non-Spring Return SMU... series Non-Spring Return SMU... series Product overview New Generation Non-spring return actuator Open/Close, 3-point AC 24 V 5/6 Hz, DC 24 V Auxiliary switch build-in SPD AC..24 V 5/6 Hz AC 23 V 5 Hz (Open/Close)

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating

More information

2. A E LM Form-fit versions Linear adapter ZH-LM

2. A E LM Form-fit versions Linear adapter ZH-LM Actuators for heating, ventilation, air-conditioning 2. A1-90122 - E LM Form-fit versions Linear adapter ZH-LM OEM at001707 at00205 Linear adapter ZH-LM: For LM2... damper actuators with universal spindle

More information

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet LHA-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Accessories. Technical Data Extension Height 2" Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit

Accessories. Technical Data Extension Height 2 Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit The CCV-EXT-KIT can be used with most CCV s* and PICCV in order to achieve a large clearance over the pipe. The Extension Kit will provide an additional 2 of space between the top of the valve and the

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21) EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp

More information

AF Series Spring Return Direct Coupled Actuator

AF Series Spring Return Direct Coupled Actuator AF Series Spring eturn Direct Coupled Actuator Minimum in-lb torque For damper areas up to 5 sq-ft* (For lower torque, see NF, LF, or TF series) Applications emove for / to.5 shafts ZG6 or ZG 7 bracket

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch echnical data sheet Damper actuator LM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Fire and Smoke Damper Actuator product overview

Fire and Smoke Damper Actuator product overview Fire and Smoke Damper Actuator product overview Fire and Smoke protection Spring-Return Actuator BLF.. BF.. BFG.. FSLF..US FSNF..US FSAF..US Agency listing CE certification UL555 and UL555S Torque - Motor

More information

In operation At rest For wire sizing

In operation At rest For wire sizing NMQ24A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC/DC 24V Control: Open-close (not made

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation

More information

Versatile and Powerful

Versatile and Powerful AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)

More information

AM Series Direct Coupled Actuator

AM Series Direct Coupled Actuator AM Series Direct Coupled Actuator Versatile and Powerful Minimum 60 in-lb torque in a compact package. For damper areas up to 0 sq-ft*. Areas of Application Direct Coupled up to / standard shafts or Jackshafts

More information

Versatile and Powerful

Versatile and Powerful LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)

More information

See «Overview of types»

See «Overview of types» echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating

More information

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation

More information

FSAF24(-S) US, FSAF120(-S) US

FSAF24(-S) US, FSAF120(-S) US FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply

More information

Minimum 27 in-lb Torque

Minimum 27 in-lb Torque LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SM4A-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm Nominal

More information

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...

More information

Minimum 27 in-lb torque

Minimum 27 in-lb torque LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SMA-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque m ominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point Actuators Technical data sheet Rotary drive Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor Nominal Voltage Control Damper size Damper

More information

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 50 Nm Nominal voltage AC 4 V Control: Open-close or -point Auxiliary switch Technical data Electrical data Nominal

More information

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator NFB and NFX Series Spring Return Direct Coupled Actuator Minimum 90 in-lb Torque For damper areas up to sq-ft* Applications 1 3/4 1/ New standard clamp fits standard 1/ shafts to 1.05 jackshafts. Mount

More information

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations

More information

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories MX4X-6XXX Series MX4X-7XXX Series Selection Guide DuraDrive Series Actuators and Accessories Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning

More information

BELIMO CONTROLS

BELIMO CONTROLS INDEX ACCESSORIES MECHANICAL CRANK ARM ADAPTOR KITS... 7-17 JACKSHAFT LINKAGE FOR SPRING RETURN DAMPER ACTUATORS... 7-17 MISCELLANEOUS... 7-17 MOUNTING BRACKETS... 7-17 DAMPER ACTUATORS FIRE AND SMOKE

More information

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18) AF Series Spring Return Direct Coupled Actuator Minimum 133 in-lb torque For damper areas up to 35 sq-ft* (For lower torque, see NF, LF, or TF series) Applications Remove for 3/4 to 1.05 shafts ZG106 or

More information

AF Series Spring Return Direct Coupled Actuator

AF Series Spring Return Direct Coupled Actuator AF Series Spring Return Direct Coupled Actuator Minimum in-lb torque For damper areas up to sq-ft* (For lower torque, see NF or LF series) Applications Direct Coupling - The Belimo Concept Remove for /

More information

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6

More information

GM Series Direct Coupled Actuator

GM Series Direct Coupled Actuator GM Series Direct Coupled Actuator Minimum 3 in-lb torque** For damper areas up to 8 sq-ft* Applications Linkage is part of inlet vane assembly supplied by manufacturer. Actuator is mounted to vortex frame.

More information

Non-Spring Return EconoDrive Floating Actuator

Non-Spring Return EconoDrive Floating Actuator MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

AFXUP-S (p. 19) AFB24-MFT. AFXUP (p. 19) AFBUP-S

AFXUP-S (p. 19) AFB24-MFT. AFXUP (p. 19) AFBUP-S AF and AFX Series Spring eturn Direct Coupled Actuator Minimum 180 in-lb Torque For damper areas up to 4 sq-ft* (For lower torque, see AF, NF, NFX, LF, or TF series) Applications 1 3/4 1/2 New standard

More information

LF Series At A Glance

LF Series At A Glance LF Series Spring Return Direct Coupled Actuator Minimum 35 in-lb Torque For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators echnical Databook Version 6.2 Belimo Asia Pacific Product Overview and able of Contents able of Contents 2 Control Valves and Actuators Product Overview 3 Characterised

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

SM24A. Technical data. Dimensions [mm]

SM24A. Technical data. Dimensions [mm] SM24A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V Electrical data Nominal voltage AC 24V, 5/6Hz / DC

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet DRK24A-5 SuperCap rotary actuator with emergeny control function and extended functionalities for butterfly valves Nominal torque 9 Nominal voltage AC/DC 24 V Control Open-close Design

More information

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

Actuators for air shutters 4Nm. 2 or 3 points control. Advantages: Selection model table. Runing time. Shutter s area

Actuators for air shutters 4Nm. 2 or 3 points control. Advantages: Selection model table. Runing time. Shutter s area Actuators for air shutters 4Nm 2-3 points control Lufberg presents actuators with torque 4Nm for using in heating, air conditioning and cooling systems. High quality level DA04N serie are intended for

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

M9216 Series Electric Spring Return Actuators

M9216 Series Electric Spring Return Actuators *34636461G* 34-636-461, Rev. J Installation Instructions M9216 Issue Date October 217 M9216 Series Electric Spring Return Actuators Installation IMPORTANT: The M9216 Series actuator is intended to control

More information

ZG106 or ZG 107 bracket

ZG106 or ZG 107 bracket NF Series Spring Return Direct Coupled Actuator Minimum 60 in-lb torque For damper areas up to 15 sq-ft* Applications K4-1 US Clamp ZG106 or ZG 107 bracket Mount directly to 1.05 jackshafts with accessory

More information

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4. TF Series Spring Return Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 4.5 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

SQN9... Damper Actuators. Building Technologies HVAC Products. SQN9..., front (covers removed) SQN9..., rear (covers fitted)

SQN9... Damper Actuators. Building Technologies HVAC Products. SQN9..., front (covers removed) SQN9..., rear (covers fitted) 7 806 SQN9..., front (covers removed) Damper Actuators SQN9..., rear (covers fitted) SQN9... Reversible electromotoric actuators for air dampers and valves of oil or gas burners of small to medium capacity.

More information

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 5 Nm Nominal voltage C 4 V Control: Open-close or -point uxiliary switch Technical data Electrical data Nominal

More information

Minimum 18 in-lb Torque

Minimum 18 in-lb Torque CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R

More information

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam Document No. 125-4361 VF461H Series odulating Control Valves with agnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam Description Control valves with magnetic actuators,

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 24 V Nominal voltage frequency Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps:

More information

Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet DRC4G--7 Rotary actuator for butterfly valves for outdoor applications orque 90 Nm (not constant) Nominal voltage AC/DC 4 V Control: Open-close IP66 Optimum protection against moisture

More information

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 ISO 9001 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Run times: - SQM1...

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque For damper areas up to 8 sq-ft* LF actuator Applications Cost effective quality and performance for a range of applications including:

More information

Commercial Actuator Selection Chart Non-Spring Return

Commercial Actuator Selection Chart Non-Spring Return Commercial Actuator Selection Chart Non-Spring Return Control Signal Position Feedback Torque Aux. Switches Actuator Model 4 VAC Power Input On/Off Tri-State Floating 0 to 0 VDC 0 to 0 ma* 4 to 0 ma 0

More information

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150 NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150 NVCB 9000 series NENUTEC ball valves with characterised discs are especially designed and produced for applications

More information

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL S000 / S000 SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR MODULATING AND FLOATING CONTROL GENERAL These direct-coupled damper actuators provide modulating / floating control for:

More information

TRF.. series spring return rotary actuators for CCV

TRF.. series spring return rotary actuators for CCV TF.. series spring return rotary actuators for CCV Spring return rotary actuators: For ball valves DN 5.. Torque: 2 Nm Modulating control TF24-S (C/DC 24 V) Floating (3-point) control TF24-2 (C/DC 24 V)

More information

Electromotoric Actuators

Electromotoric Actuators 4 505 SQL3500 SQL8500 Electromotoric Actuators for VKF46 butterfly valves SQL3500 SQL8500 SQL35, SQL36E operating voltage AC 230 V, 3-position control signal SQL85 operating voltage AC 24 V, 3-position

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2 Centered (Default) 3/4 Centered (Field Selectable) NF24-SR (-S) US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for 2 to 1 VDC, or 4 to ma Control Signal. Output Signal of 2 to 1 VDC for Position Indication Torque min. 6 in-lb, for control

More information

G3 (D) 3-way Globe Valve, Bronze Trim

G3 (D) 3-way Globe Valve, Bronze Trim G3 (D) 3-way Globe Valve, Bronze Trim pplication This valve is typically used in ir Handling Units on heating or cooling coils and Fan Coil Unit heating or cooling coils. Some other common applications

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 SQL33 Electromotoric Actuators for valves with 90 angle of rotation SQL33 operating voltage AC 230 V SQL33 operating voltage AC 230 V operating voltage AC 24 V 3-position control signal Nominal angle

More information

Electromotoric actuators

Electromotoric actuators s 4 520 ACVATIX TM Electromotoric actuators SQL321B.. SQL361B.. For VKF42.. butterfly valves SQL321B.. Operating voltage AC 220 V, 2-position (SPDT) control signal SQL361B.. Operating voltage AC 220 V,

More information

Mechanical Fail-Safe Damper Actuator NFA

Mechanical Fail-Safe Damper Actuator NFA 2-FON echnicl Fil-Sfe Dmper Actutor NFA ctutor emergency function for djusting ir dmpers in ventiltion nd ir conditioning systems in uildings orque Nm Nominl voltge AC 24..4V / DC 24..V Control: Open-close

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL SPECIFICATIONS PRODUCT DATA Supply voltage CN6105/CN6110 Nominal voltage CN6105/CN6110 24 Vac/dc

More information

S1024-2POS / S POS S2024-2POS / S POS

S1024-2POS / S POS S2024-2POS / S POS GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:

More information

pressure independent characterized control tm

pressure independent characterized control tm 5 pressure independent characterized control tm valves (PICCV ) PICCV reacts to pressure variations, performing a continual balancing function to maintain system performance at varying loads. Wide range

More information

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control Document No. 55-8P25 EA 599-4 EA379R Description The Flowrite EA 599 Series SKD Electronic Valve Actuator requires a 24

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators Technical Databook Version 8.6 Belimo Asia Pacific Contents Control Valves and Actuators Product Overview 4 Characterised Control Valve 6 Sizing of Ball Valves

More information

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk Electro Controls Damper Actuators / Valve Motors - 2017 WattsIndustries.co.uk Damper Actuators / Valve Motors Section 21 DAMPER / VALVE MOTORS 4Nm 2 & 3 POINT EK4.. These small motors can be fitted directly

More information

Type 231 ACTUATOR FOR DAMPERS. G R U N E R t h e. f r i e n d l y a l t e r n a t i v e. Actuator with rotation drive. 20 Nm 30 Nm

Type 231 ACTUATOR FOR DAMPERS. G R U N E R t h e. f r i e n d l y a l t e r n a t i v e. Actuator with rotation drive. 20 Nm 30 Nm ACTUATOR FOR DAMPERS Type 231 Actuator with rotation drive 2 Nm Nm For the application with Room ventilation techniques VAV Valves Page: Content: 2 3 4-9 1-16 17 18-19 2 General overview Summary 231, 2

More information