1 GAFIK Systems lp are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Work directly with incandescent, magnetic low voltage, and neon/cold cathode lighting, as well as Lutron TuWireTM Fluorescent Ballasts. Work with electronic low voltage lighting via Power Interfaces. Work with 3-wire AC motors through motor modules. Panels are prewired - just bring in feed and load wiring. Surface or recess mount between 16 center to center studs. Models available with: V, V (non CE), or 230V (CE) input power. 1 to 8 Modules for 4 to 32 dimming legs. Different feed types and breakers. work with: GX-4000 Control Units. GAFIK 5000TM, GAFIK 6000, and GAFIK 7000 Systems. GP Panels and XP Switching Panels. DMX512 dimming systems via the 2LIKTM option. Standard-Size LP4/28 LP8/32 Mini LP1/4 LP3/12 Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

2 GAFIK Systems Specifications lp Standards UL Listed (eference: UL File 42071). Complies with CSA, OM, or CE (where appropriate). Power Input power: V, V (non CE), and 230V (CE). All voltages 50/60Hz, phaseto-neutral. Branch Circuit Breakers: UL-rated thermal magnetic. AIC ratings: V 10, V 6, V (CE) 6,000 Lighting strike protection: Meets ASI/IEEE standard Can withstand voltage surges of up to 6000V and current surges of up to 3000A. 10-year power failure memory: Automatically restores lighting to scene selected prior to power interruption. Sources/Load Types Operate these sources with a smooth continuous Square Law dimming curve or on a full-conduction non-dim basis: Incandescent (Tungsten)/Halogen Magnetic Low Voltage Transformer Lutron Tu-WireTM Electronic Fluorescent Ballasts eon/cold Cathode Operate these sources via Power Interfaces: Electronic Low Voltage Transformer via dedicated internal Modules or external Power Interfaces. Lutron Electronic Fluorescent Ballasts via external Power Interfaces. Operate HID sources on a full conduction non-dim basis. Modules Each Module can handle a fully loaded electrical circuit - up to four dimming legs per Module. Maximum atings: Voltage Capacity per Capacity per Module Leg V 16 A 16 A V 16 A 16 A (non-ce) 230 V (CE) 13 A 10 A TISSTM filter circuit technology compensates for incoming line voltage variations: o visible flicker with +/-2% change in MS voltage/cycle and +/-2% Hz change in frequency/second. Internal: Prewired by Lutron. System communications: Low-voltage Class 2 (PELV) wiring connects Panels to other components. Line (mains) voltage: and load wiring only. o other wiring or assembly required. Setup Circuit Selector electronically assigns dimming legs to zones and sources. Permits reassignment of zones and sources without rewiring. Physical Design Enclosure: EMA-Type 1, IP-20 protection; #16 U.S. Gauge Steel. Indoors only. Weight: 27lb (13kg) for Mini LP, 63lb (29kg) for Standard-Size LP. Mounting Surface mount or recess mount between 16" (40cm) studs. Allow space for ventilating. Environment F (0-40 C). elative humidity less than 90% non-condensing. Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

3 GAFIK Systems Anatomy of a LP Model umber lp L P 7 / I S C G P _ Prefix umber of Modules Voltage Branch Circuit Breaker ating Panel Custom Panel Suffix Type Prefix: LP for LP Panel umber of Modules: Indicates number of dimming modules in the panel. Also indicates number of full load circuits. umber of Legs: Indicates number of dimming legs in the panel. Each module has four dimming legs. Voltage: 120 for V 230 for CE 240 for non-ce Type: 2 for 1 phase 2 wire 3 for 1 phase 3 wire (split phase) 4 for 3 phase 4 wire Panel : umber of Legs ML for Main Lugs only Mxx for Main Breaker with xx = breaker size in Amps (custom panel option) IS for Isolation Switch (CE/non-CE only) Branch Circuit Breaker ating: 20 for 20 A branch circuit breakers (120 V only) 15 for 15 A branch circuit breakers (120 V only) 13 for 13 A branch circuit breakers (230 V CE only) 16 for 16 A branch circuit breakers (240 V non-ce only) Custom Panel Suffix: Indicates panel with special options Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

4 GAFIK Systems Mini LP Models 230V (CE) Power lp umber Of Modules umber Of Legs Type Maximum Panel LP1 LP2 LP Ø, 2W 1Ø, 2W 1Ø, 2W 3Ø, 4W 13A 26A 39A 13A 13A Branch Circuit Breakers Wire Sizes Power (Hot/Live) (connect directly to Branch Circuit Breakers): 230V (CE) #18 AWG (1.0mm 2 ) to #4 AWG (25mm 2 ) eutral (connects to eutral Lug): 230V (CE) #14 AWG (2.0mm 2 ) to #8 AWG (6.0mm 2 ) Load All Models #14 AWG (2.0mm 2 ) to Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

5 GAFIK Systems Standard-Size LP Models 230V (CE) Power lp umber Of Modules umber Of Legs Type Maximum Panel Branch Circuit Breakers LP4 16 3Ø,4W 125A LP5 LP Ø,4W 3Ø,4W 125A 125A Isolation Switch Only 13A LP7 28 3Ø,4W 125A LP8 32 3Ø,4W 125A Wire Sizes to Isolation Switch (CE/non-CE only): Power (Hot/Live) (3) 2.5mm 2 to 35mm 2 eutral (1) 2.5mm 2 to 35mm 2 Load All Models #14 AWG (2.0mm 2 ) to Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

6 GAFIK Systems lp Mini LP Dimensions Top View (365.25) Left Side View 2.21 (56.05) Front View (403.23) 8.00 (203.2) ight Side View (105.36) 0.15 (3.81) (609.6) (546.1) (622.3) 1.34 (33.94) Cover 2.21 (56.05) (273.05) (384.3) Bottom View 4.09 (103.84) All dimensions in inches (mm). Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

7 GAFIK Systems Standard-Size LP Dimensions lp (365.13) Top View Left Side View 2.43 (61.85) (403.23) Front View 8.00 (203.2) ight Side View 4.21 (106.93) (3.81) 2.69 (68.25) ( ) ( ) ( ) Cover 2.43 (61.85) (279.4) (394.18) Bottom View All dimensions in inches (mm) (105.41) Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

8 GAFIK Systems Mini LP Mounting lp Surface or recess mount indoors. Consult Dimensions page for dimensions and conduit knockout locations. Panel generates heat. Mount only where ambient temperature is F (0-40 C). This equipment is air-cooled. Do not block vents or warranty will be void. Mount Panels where audible noise is acceptable (internal relays click). Mount Panels so line (mains) voltage wiring is at least 6 feet (1.8m) from sound or electronic equipment and wiring. Mount Panel within 7 of true vertical. Surface Mounting Surface mounting keyholes accept 1/4 (6 mm) mounting bolts. This size is recommended. Panel Maximum Weight BTUs/hour Without Packaging LP lb (15kg) LP lb (16kg) LP lb (17kg) Maximum and Wire Sizes Consult Overview page. ecess Mounting Mount Panel flush to 1/8" (3mm) below finished wall surface. Allow room for top cover. Leave 1 1/2" (38mm) clearance to each side of Panel. Front View Side View Front View Side View Terminal Blocks for Legs to Loads and Legs to loads Terminal Blocks for Legs to Loads and Legs to loads Class 2 (PELV) Do ot Block Vents Class 2 (PELV) Do ot Block Vents and Legs to loads Branch Circuit Breakers and Legs to loads Branch Circuit Breakers Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

9 GAFIK Systems Standard-Size LP Mounting lp Surface or recess mount indoors. Consult Dimensions page for dimensions and conduit knockout locations. Panel generates heat. Mount only where ambient temperature is F (0-40 C). This equipment is air-cooled. Do not block vents or warranty will be void. einforce wall structure for weight and local codes. Mount Panels where audible noise is acceptable. (Panels hum slightly and internal relays click.) Mount Panels so line (mains) voltage wiring is at least 6 feet (1.8m) from sound or electronic equipment and wiring. Mount Panel within 7 of true vertical. Surface Mounting Surface mounting keyholes accept 1/4 (6mm) mounting bolts. This size is recommended. Panel Maximum Weight BTUs/hour Without Packaging LP lbs (25kg) LP lbs (26kg) LP lbs (27kg) LP lbs (28kg) LP lbs (29kg) Maximum and Wire Sizes Consult Overview page. ecess Mounting Mount Panel flush to 1/8" (3mm) below finished wall surface. Allow room for top cover. Leave 1 1/2" (38mm) clearance to each side of Panel. Front View Side View Front View Side View Terminal Blocks for Legs to Loads and Legs to Loads Terminal Blocks for Legs to Loads and Legs to Loads Do not block vents 12" (31cm) minimum clearance Do not block vents 12" (31cm) minimum clearance and Legs to Loads 8 7 Class 2 (PELV) 8 7 Class 2 (PELV) Main Lugs Main Lugs Preferred Class 2 (PELV) Preferred Class 2 (PELV) Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

10 GAFIK Systems Mini LP Load Terminal Blocks Bypass Jumpers: Do not remove until load wiring is verified! H DH DH DH H Mini LP (Cover Off) lp Tips Wire the Mini LP similar to wiring a lighting Distribution Panel: un feed and load wiring. o other wiring or assembly required. un separate neutrals for each module - no common neutrals across phases. The Mini LP can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Modules. Use Branch Circuit Breakers to switch lights on and off. Branch Circuit Breakers eutral Lug Power (Hot/Live) eutral Power (Hot/Live) V #14 AWG (2.0mm 2 ) to V #18 AWG (1.0mm 2 ) to 230V (CE) #4 AWG (25mm 2 ) eutral V #14 AWG (2.0mm 2 ) to #2/0 AWG (70mm 2 ) V #14 AWG (2.0mm 2 ) to 230V (CE) #8 AWG (6.0mm 2 ) Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

11 GAFIK Systems Standard-Size LP Load Bypass Jumpers: Do not remove until load wiring is verified! DH DH DH DH H Standard LP (Cover Off) lp Tips Wire the Mini LP similar to wiring a lighting Distribution Panel: un feed and load wiring. o other wiring or assembly required. un separate neutrals for each module - no common neutrals across phases. The LP can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Modules. Use Branch Circuit Breakers to switch lights on and off. Terminal Blocks Branch Circuit Breakers eutral Lug Power (Hot/Live) (3) #14 AWG (2.0mm 2 ) to #2/0 AWG (70mm 2 ) eutral #2/0 AWG (70mm 2 ) Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

12 GAFIK Systems Typical Legs for 230V (CE) lp All Load Types except Lutron Hi-lume or Eco-10TM (ECO-Series) Fluorescent Ballasts Electronic Low Voltage Load Dimmed Live eutral Bypass Jumpers: Do not remove! L Electronic Low Voltage Use Lutron ELVI Electronic Low Voltage Interface. Transformer ELVI Dimmed Live eutral Bypass Jumpers: Do not remove! L Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

13 GAFIK Systems lp Low-Voltage Class 2 (PELV) (All Models) System communications use low-voltage Class 2 wiring. must be daisy-chained. must run separately from line (mains) voltage. GAFIK Eye 4000 System Class 2 (PELV) wiring link requires: Two #12 AWG (2.5mm 2 ) conductors for control power. One twisted, shielded pair of #18 AWG (1.0mm 2 ) for data link. One #18 AWG (1.0mm 2 ) conductor for Emergency (Essential) sense line, from panel to panel. Total length of Control Link may be no more than 2,000 ft. (610m). Approved low-voltage cable is available from Lutron, 1 Belden, and Liberty. These are approved with #22 AWG data link wires. LP Panels Control Interface Control Unit Wallstations GAFIK 5000TM/6000 /7000 System Class 2 (PELV) wiring link requires: Two #12 AWG (2.5mm 2 ) conductors for control power. One twisted, shielded pair of #18 AWG (1.0mm 2 ) for data link. One #18 AWG (1.0mm 2 ) conductor for emergency (essential) sense line, from panel to panel. Total length of Control Link may be no more than 2,000 ft. (600m). If -PT interface and GX-CBL-46L cable 1 is used, length may be up to 4,000 ft. (1200m). LP Panels 5000/6000/7000 Processor Control Interface Control Unit Wallstations efer to GAFIK 5000/6000/7000 Specification 1 GX-CBL-46L Class 2 (PELV) wiring cable is available from Lutron and contains: Two #12 AWG (2.5mm2) conductors for control power. One twisted, shielded pair of #22 AWG (0.625mm2) for data link. One #18 AWG (1.0mm2) conductor for emergency (essential) sense line. Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

14 GAFIK Systems Class 2 (PELV) Panel-to-Panel (All Models) lp To additional Power Panels 1 2 3,4 5 Control (2) #12 AWG (2.5 mm 2 ) 1: Common 2: 24VFW Data Link (1) shielded, twisted pair #18 AWG (1.0 mm 2 ) 3: 4: Shield/Drain (1) #18 AWG (1.0 mm 2 ) 5: Sense Line 1 2 3,4 Shield/Drain To Lighting Controls or Processors D D 5 Common +24VFW Drain Sense Data A OK Power Data B OK Link A B Link D 5 C D SELECT CICUIT 1 Common Drain Common +24VFW Drain Sense Data A OK Power Data B OK Link A B Link D 5 C D SELECT CICUIT 1 Common Drain 2 2 Circuit Circuit LP Panel 1 LP Panel 2 otes: Emergency Power: The additional #18 AWG (1.0mm 2 ) wire is a sense line from terminal 5 of another Panel. This sense line allows an Emergency (Essential) Lighting Panel to sense when ormal (on-essential) power is lost. If more than one Emergency Lighting Panel needs to sense from a specific ormal Panel, a dedicated wire between each pair of ormal (on- Essential) and Emergency (Essential) panels may be required. Shield/Drain: Connect shielding as shown. Do not connect to Ground (Earth) or circuit board of Circuit Selector. Connect the bare drain wires and cut off the outside shield. Class 2 (PELV) Terminal Connections Each low-voltage Class 2 (PELV) terminal can accept only two #18 AWG (1.0mm 2 ) wires. Two #12 AWG (2.5mm 2 ) conductors won't fit. Connect as shown using appropriate wire connectors. (4) #12 AWG (2.5mm 2 ) D 5 Common 24VFW Data A OK Drain Sense D 5 A Link Power Data B OK Link B Comm Drain C D Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

15 GAFIK Systems Options lp Consult Lutron for ordering information and model numbers. Dimensions and wiring may change based on options chosen. Option Description Application Double Lug Sets Allows multiple Panels to be fed from the same feed. A single feed and multiple LP Panels are required. Branch Circuit Protection Lutron Ten Volt Module (TVM) 2LinkTM Branch Circuit Breakers with higher AIC ratings than those on standard Panels. Panels can also have Branch Circuit Breakers with special ratings such as: GFI (Ground Fault Interrupt) ELB (Earth Leakage Breaker) CD (esidual Circuit Device). Allows Panels to operate fluorescent ballasts that meet IEC 929 standards for 0-10V control including: Lutron s TVE ballasts 0-10V neon PWM fluorescent Tridonic DSI (Digital Serial Interface). The TVM can sink or source 50mA (typically ballasts) on each circuit. Allows a DMX512 theatrical console to operate Panels load circuits. Allows a GAFIK Eye 4000 Series to handle 128 zone (two links of 64 zones). The two links are independent and do not communicate. Contact Lutron for further details. Jobs with fluorescent ballasts that require 0-10V, PWM, or DSI control. Control of architectural lighting from a DMX512 theatrical console is required. A mix of architectural and theatrical lighting exists on the job. Tridonic is a registered trademark of Zumtobel AG. Job ame: SPECIFICATIO SUBMITTAL Model umbers: Job umber:

GP Dimming Panels 230 Volt (CE)

GP Dimming Panels 230 Volt (CE) GAFIK Systems 30 Volt (CE) gp- 03.0.04 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim.

More information

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL rev gp-a 7.0.00 GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available

More information

GP Dimming Panels 230 Volt (CE)

GP Dimming Panels 230 Volt (CE) 30 Volt (CE).3.08 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim. Models available with:

More information

Phase-Adaptive Power Module

Phase-Adaptive Power Module GAFIK Eye papm-1 3.12.08 Description Provides capability for a zone on a GAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic

More information

LCP128T Spec Grade Dimming System

LCP128T Spec Grade Dimming System LCP128T Spec Grade Dimming System 369-642a 1 06.04.12 System Overview LCP128T is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels

More information

Phase-Adaptive Power Module

Phase-Adaptive Power Module Phase-Adaptive Power Module Provides dimming control for 1 zone of a full 16 A lighting load. May be used to dim incandescent, halogen, electronic low-voltage, magnetic low-voltage, neon/cold cathode.

More information

3-Wire Fluorescent Power Module

3-Wire Fluorescent Power Module 369355 Rev B 1 09.02.11 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to dim fluorescent lights that have Lutron Hi-lumeR and Eco-10R (Eco Series) line-voltage

More information

Phase-Adaptive Power Module with 3-Wire Fluorescent Input

Phase-Adaptive Power Module with 3-Wire Fluorescent Input 369-358c 1 03.19.12 Description When connected to a 20 A circuit breaker, provides capacity on a 3-wire fluorescent dimmer for a full 16 A load of lighting. May be used to dim incandescent, halogen, electronic

More information

Switching Power Module

Switching Power Module 369357d 1 06.20.13 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic

More information

DIN Power Module - Phase Adaptive

DIN Power Module - Phase Adaptive DI Power Module ow Capacity Phase Adaptive DI Power Module - Phase Adaptive 369849d 1 07.29.16 The Phase Adaptive Power Module family is a group of modular products for the control of lighting loads. This

More information

DIN Rail Power Module

DIN Rail Power Module 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A www.lutron.com +44.(0)20.7702.0657 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller DIN Rail odule The DIN Rail odule family

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

Wired Vareo Local Lighting Controls

Wired Vareo Local Lighting Controls Wired Vareo Local Lighting Controls 8 Series Local Lighting Controls D48 Bus Architectural-Style L o c a l l i g h t i n g c o n t r o l s Wired Vareo local lighting controls function much like standard

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron bus supplies (Eco-10 and Hi-lume

More information

Wired Maestro Local Controls

Wired Maestro Local Controls Wired Maestro Local Controls 4 Series / 8 Series Local Controls H48 Bus Designer-Style L O C A L c o n t r o l s Wired Maestro local controls function much like standard dimmers and switches, but can be

More information

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming Hi-lume LED Overview Hi-lume LED 1 12.11.9 Hi-lume LED is a high-performance, constant current driver that provides energy-efficient dimming for LED lighting. With industry-leading full-range % to 1% dimming,

More information

EcoSystemR Multiple Control Input Ballasts

EcoSystemR Multiple Control Input Ballasts EcoR Multiple Control s 369454h 1 09.15.14 Digital electronic dimming ballasts maximize the benefits of a lighting management system. EcoR s offer 100% to 10% dimming; ideal for use where saving energy,

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Five Control Digital Dimming s Eco Multiple Control s 369454l 1 09.02.16 Digital electronic dimming ballasts maximize the benefits of a lighting management system. Eco s offer 100% to 10% dimming;

More information

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface Lutron Power Interfaces Ten Volt Interface 36947d 07.07.4 Features 00-77 V~ forward, reverse, and center phase control input capability Provides control and switching capabilities to switch and dim current

More information

INSTALLATION. **Microprocessor Status LED:

INSTALLATION. **Microprocessor Status LED: INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East Orem, Utah 84097 Telephone 801 229 2800 Fax 801 224 0355 Standard Dimmer Module MODEL: SDM12-EM Overview The SDM12 dimmer module

More information

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. Power Switching Introduction CRESTRON GREEN LIGHT power switching cabinets come pre-configured with GLXP modules already installed. The cabinets only require installation and wiring of feed and load circuits.

More information

Controls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES

Controls.   CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES SPECIFICATION SUBMITTAL s The contractor s choice in rugged, linear slide dimmers. www.lutron.com/nova CONTROLS AND ACCESSORIES Slide-to-Off s Preset s Select light level with slider; slide down to off

More information

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface Lutron Power Interfaces Ten Volt Interface 369247e 1 07.07.16 Features 100-277 V~ forward, reverse, and center phase control input capability Provides control and switching capabilities to switch and dim

More information

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase. Installation Instructions Please Leave for Occupant HP-2, HP-4, & HP-6 Dimming Module 120/277VAC, 60Hz Description Dimming Module HP-2 2000W/VA 16A@120/277V 60Hz Listed Industrial Equipment 243C Dimming

More information

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface Lutron Power Interfaces Ten Volt Interface 369247c 1 09.17.13 Features 100-277 V~ forward, reverse, and center phase control input capability Provides 0-10 V- control and switching capabilities to switch

More information

Installation & User Instructions

Installation & User Instructions Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.

More information

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A) TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user

More information

ALD Dimmer Enclosures

ALD Dimmer Enclosures ALD Enclosures FEATURES Attractive crinkle black finish. er Connection Power Supply Neutral Taps Modules (not included) Cooling Fans Dimming Electronics (not included) Available in 2 sizes: ALD6 (6 dimmer

More information

Maestro Wireless Dimmers and Switches

Maestro Wireless Dimmers and Switches Maestro Wireless Dimmers and The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers energy savings,

More information

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A) TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29132-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the

More information

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts TVE Overview Eco-0TM TVETM 0% TVE () 02.9.04 The (Eco-0) TVE is a 0% fluorescent dimming ballast for applications using a 0-0V control. TVE ballasts are also designed to work seamlessly with 0-0V lighting

More information

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Elegance Electrician s Installation Guide

Elegance Electrician s Installation Guide Elegance Electrician s Installation Guide CentraLite Systems, Inc. 6420 Wall St. Mobile, AL 36695 Phone: 877-466-5483 Fax: 251-607-9119 2003-2005 CentraLite Systems, Inc. Revised 10/20/2005 ELECTRICIAN

More information

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps 3-Wire Control, 220/240 Volt T-8 Linear, rev hi-220-240-1b 1.10.02 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) HOT DIMMED HOT NEUTRAL Hi-lume Power Control Dimming Ballast Lamps DESCRIPTION Continuous,

More information

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube 3-Wire Control, 120, 277 Volt, T4 Quad Tube and T4 Triple Tube rev hi-compact-1a 3.7.01 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) T4 - One Lamp 3.00 w (76mm) x 1.00 h (25mm) x4.90 l (124mm) T4 - Two

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options Product Description The SED2 Electronic Bypass (E-Bypass) Options are companion packages for the family of SED2 Variable Frequency Drives

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........

More information

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 EC3DT4MWKU1S 26/32W T4 1LMP Ba Lutron Catalog Number Manufacturer Description Weight per unit Product Category EC3DT4MWKU1S

More information

4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! Description. System Specifications. Installation Instructions Occupant Copy

4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! Description. System Specifications. Installation Instructions Occupant Copy Installation Instructions Occupant Copy 4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! The GRXSLD Control Units are designed for residential or commercial applications indoor use

More information

HomeWorksR QS Wired MaestroR Architectural Local Controls

HomeWorksR QS Wired MaestroR Architectural Local Controls HomeWorks QS Wired Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where

More information

Maestro Wireless Dimmers and Switches

Maestro Wireless Dimmers and Switches Maestro Wireless Dimmers and Switches The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers energy

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

Compact SE Overview. High-Performance Dimming. Ballast

Compact SE Overview. High-Performance Dimming. Ballast Compact SE Overview CompactSE 01.10.10 For designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your solution.

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

RTA-RX-F-SC and RTA-RX-F-SC-347

RTA-RX-F-SC and RTA-RX-F-SC-347 RadioTouch Controller for Lights, Sivoia QED Controllable Window Shading System, and Contact Closures and -347 Description The RadioTouch lights, Sivoia QED ultra-quiet controllable window shading system,

More information

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming cosystem Hi-lume % rchitectural imming Hi-lume Overview 369-398c 06.04. Hi-lume architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. y providing industry

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Compact SE Overview. High-Performance Dimming. Ballast

Compact SE Overview. High-Performance Dimming. Ballast allast Compact SE Overview CompactSE- 03.08.04 or designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,

More information

SO-SVCN- - GRAFIK Systems Sivoia QEDTM Controller

SO-SVCN- - GRAFIK Systems Sivoia QEDTM Controller N- - Sivoia QEDTM Controller N-WH-E01 Color and Finish Codes LEDs I-WH- (Insert version) Engraving so-svc-1 10.20.07 Description Provides programming and control of one group of Sivoia QEDTM Window Treatments.

More information

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number 0-10V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V 4 circuit Analog 1-10V 4 x 4 A. Dimmer pack Serial Number Dimmers Indicators Digital Lighting Systems,Inc Info@digitallighting.com

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be followed

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999 /2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

Residential Systems Control of LED Lighting (120V)

Residential Systems Control of LED Lighting (120V) Residential Systems Control of LED Lighting (120V) 1.0 Overview Light Emitting Diode (LED) lighting is becoming more prevalent in the marketplace and is often being implemented in residences in place of

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Electrical Installation

Electrical Installation Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS Dimmer Power Module - through 5 READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS! WARNING To reduce the risk of death, injury

More information

SURFACE TRACK (120/250V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS SURFACE TRACK (120/250V) SPECIFICATIONS GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed

More information

Pneumatic Isolation Module

Pneumatic Isolation Module Pneumatic Isolation Module (Cat. 2030-Pxxxxx) ATTENTION: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: Prior to beginning the installation and wiring process,

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Vive Maestro Wireless Dimmers and Switches

Vive Maestro Wireless Dimmers and Switches Vive Maestro Wireless Dimmers and Switches The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers

More information

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features LT transfer circuit for use with low-voltage down-lighting Two channel device providing switching for up to 75 watts per channel ombines existing low-voltage lighting with a 12 volt emergency unit power

More information

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the

More information

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W ova UAC (V-UAC-M) Modified Sine Wave 650W 800W 1000W ISTRUCTIOS IMPORTAT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: 1. READ

More information

Learning Module 10: Loadcenters. 101 Basic Series

Learning Module 10: Loadcenters. 101 Basic Series Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371 Sunburst SB2400 Dimmer Rack and Receiver 86(50$18$/ Version 1.02 P/N F371 Copyright 2004 Lehigh Electric Products Co. Revised January 2006 TECHNICAL INQUIRY The dimming system consists of electrical and

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information

More information

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS Supersedes: 160.75-PW2 (508) Form 160.75-PW2 (311) FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS WIRING DIAGRAM CONTRACTOR ORDER NO. YORK CONTRACT NO.

More information

Product Overview. Enclosure for batteries N PE/G. Battery (customer-provided - shown for reference only) Battery output terminals

Product Overview. Enclosure for batteries N PE/G. Battery (customer-provided - shown for reference only) Battery output terminals Product Overview Enclosure for Transformer Installation MGE TM Galaxy TM 3500 and Smart-UPS VT Enclosure for Batteries and Enclosure for Transformer 400 V Enclosure for batteries PE/G ; PE/G Unistruts

More information

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor Product Identification and Overview Power and Communication on Just Two Wires Available with Temperature Sensing, Temperature Setpoint, Optional Occupant Override, Optional Display and Optional %RH Sensing

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Output Power (W) Output Voltage (V) Output Current (A) Tcase Max 150 60~210 0.70 80 C Wiring Diagram Input Current 1.4A@120VAC 0.6A@277VAC 0.67A@250VDC Max. Input Power (W) Inrush Current (A pk /µs) Max.

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

HomeWorks QS Designer RF Maestro Local Controls

HomeWorks QS Designer RF Maestro Local Controls HomeWorks QS RF Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where

More information

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18 Zone Sensors Submittal Data English Language/IP Units SD1582EW 06/18 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and