1 GAFIK Systems 30 Volt (CE) gp GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim. Models available with: 30V input power. 3 to 4 circuits. Different feed types and breakers. work with: GAFIK Eye 4000 Control Units. GAFIK 5000TM, GAFIK 6000, and GAFIK 7000 Systems. LP Dimming Panels. XP SoftswitchTM Panels. DMX5 dimming systems via the LINKTM option.

2 GAFIK Systems Specifications - 30 Volt (CE) gp Standards Complies with CE. Power Input power: 30V, 50/60Hz, phase-to-neutral. Branch Circuit Capacity: Number of Circuits: 3-4 Branch Circuit Breakers: IEC-rated thermal magnetic. AIC rating (other ratings available): 6,000A Lightning strike protection: Meets ANSI/IEEE standard Can withstand voltage surges of up to 6000V and current surges of up to 3000A. 0-year power failure memory: Automatically restores lighting to scene selected prior to power interruption. Sources/Load Types Operates these sources with a smooth continuous Square Law dimming curve or on a full conduction non-dim basis: Incandescent (Tungsten)/Halogen Magnetic Low Voltage Transformer Electronic Low Voltage Transformer Lutron Electronic Fluorescent Dimming Ballasts Magnetic Fluorescent Lamp Ballasts Optional modules allow for control of 0-0V, DSI, and PWM load types. Operates HID sources on a full conduction non-dim basis. Internal: Prewired by Lutron. System communications: Lowvoltage Class (PELV) wiring connects Dimming Panels to other components. Line (mains) voltage: Feed, load, and control circuit wiring only. No other wiring or assembly required. Filter Chokes Load current rise time is measured at a 90 degree conduction angle, with 0V input power. 0-90% of load current waveform: - 350µSec rise time at 50% dimmer capacity µSec rise time at 00% dimmer capacity. 0-00% of load current waveform: - 55µSec rise time at 50% dimmer capacity µSec rise time at 00% dimmer capacity. At no point in the waveform can the rate of current change exceed 300mA per µsec. Consult Lutron for higher rise time options. Dimming Cards Panel current ratings are listed for continuous operation. TISSTM filter circuit technology compensates for incoming line voltage variations: No visible flicker with +/-% change in MS voltage/cycle and +/-% Hz change in frequency/second. Arcless-relay air gap-off switches (one per load circuit) ensure open load circuits when off function selected. Eliminate arcing at mechanical contacts when loads are switched. Physical Design Enclosure: NEMA-Type (Type available upon request), IP-0 protection; #6 U.S. Gauge Steel. Indoors only. Weight: pounds (4-80kg). Mounting: Surface mount only. Allow space for ventilating. Environment/Heat Dissipation Patented, ribbed aluminum heat sink base cools Panel by convection. No fans F (0-40 C). elative humidity less than 90% non-condensing. everse-phase control transformers require an ELVI Power Interface. Check phase with transformer manufacturer.

3 GAFIK Systems gp Anatomy of a GP Model Number G P I S - 0 C E - C G P - _ Prefix Number of Load Circuits Voltage Feed Type Panel Feed Custom Panel Suffix egion Suffix Branch Circuit Breakers Prefix: GP for GP Dimming Panel Number of Load Circuits: Indicates number of load circuits in the panel Voltage: 30 for CE Feed Type: for phase wire 4 for 3 phase 4 wire Panel Feed: IS for Isolator Switch Branch Circuit Breakers: 0 for branch circuit breakers egion Suffix: CE for 30 V Custom Panel Suffix: Indicates panel with special options

4 GAFIK Systems gp GP3/4 Mini Models Only standard panels listed. Consult Lutron for further options. 30V (CE) Power Number Of Circuits Feed Type Maximum Feed Panel Feed/ Branch Circuit Breakers GP3 Ø, W 3Ø, 4W 30A GP4 Feed Through GP8-4 Standard-Size Models Only standard panels listed. Consult Lutron for further options. 30V Power Number Of Circuits Feed Type Panel Feed Maximum Feed Branch Circuit Breakers GP8 GP GP6 Ø, W 3Ø, 4W 3Ø, 4W 3Ø, 4W Isolator Switch Isolator Switch Isolator Switch Isolator Switch 5A 5A 5A 5A GP0 3Ø, 4W Isolator Switch 5A GP4 3Ø, 4W Isolator Switch 5A 30V (CE) Mains CE Panels are listed as appliances. A distribution panel must provide a main circuit breaker that does not exceed the rating of the panel. Breakers located in distribution panel supplied by others.

5 GAFIK Systems gp Dimensions for GP3/4 Mini Panels Top View 5 /8 (30 mm) 3 5/8 (9 mm) 6 /4 (60 mm) 5/8 (4 mm) Class (PELV) Left Side View Front View 9 5/8 (44 mm) ight Side View 5 /4 (33 mm) 3/6 (30 mm) 8 8" (457mm) 9/" / (495mm) /8" /8 (537mm) /8 (9 mm) /8 (9 mm) 3/4 (70 mm) (79 mm) Keyhole accepts a maximum of /4 (6mm) mounting bolt. #0 M6 recommended. 3/4 (70 mm) Bottom View Load Circuit Feed 3/4 (70 mm) / (38 mm) 5 / (40 mm) / (38 mm)

6 GAFIK Systems Dimensions for GP8-4 Standard-Size Panels gp Top View 8 (7 mm) Suggested feed wiring entry Suggested load wiring entry 4 (00 mm) Left Side (50 mm) Front View (50 mm) emovable top cover is shipped in the same box as the panel. ight Side 37 (940 mm) 33 (838 mm) 35 (889 mm) 3 (330 mm) Keyhole accepts a maximum of 5/6" (8 mm) mounting bolt (/4" (m8) recommended). Class /PELV entry knockout is 7/8" dia. ( mm) (304 mm) Bottom View (50 mm) equired control wiring entry (304 mm)

7 GAFIK Systems GP3/4 Mini Panel Mounting gp Surface mount indoors. Panel generates heat. Mount only where ambient temperature will be 0-40 C (3-04 F). This equipment is air cooled. Do not block vents or warranty will be void. Leave " (3cm) clearances above, below, and in front of Panel. No clearance necessary on sides. einforce wall structure for weight and local codes. GP3/4 Front View Terminal Blocks for Load Circuits Class (PELV) GP3/4 Side View " (3cm) minimum top and front Panel GP3/4 Maximum BTUs/Hour 685 Weight (without packaging) 30 lbs. (4kg) Branch Circuit Breakers Dimming Panels will hum slightly and internal relays will click while in operation. Mount where audible noise is acceptable. Mount Panels so line (mains) voltage wiring is at least 6 feet (.8m) from sound or electronic equipment and wiring. GP Panels must be mounted within 7 of true vertical. Load Circuit Feed aceway " (3cm) minimum For maximum Feed and Wire Sizes, consult Overview page. Water damages Panels! Install Panels in a location where they will not get wet.

8 GAFIK Systems GP8-4 Standard-Size Panel Mounting gp Surface mount indoors. Panel generates heat. Mount only where ambient temperature will be 0-40 C (3-04 F). This equipment is air cooled. Do not block vents or warranty will be void. Leave " (3cm) clearances above, below, and in front of Panel. Leave clearance on sides for Class (PELV) wiring. einforce wall structure for weight and local codes. Panel GP8 GP GP6 GP0 GP4 Maximum BTUs/Hour Weight (without packaging) 5 lbs. (5kg) 30 lbs. (59kg) 45 lbs. (66kg) 60 lbs. (73kg) 75 lbs. (80kg) Dimming Panels will hum slightly and internal relays will click while in operation. Mount where audible noise is acceptable. Mount Panels so line (mains) voltage wiring is at least 6 feet (.8m) from sound or electronic equipment and wiring. GP Panels must be mounted within 7 of true vertical. GP8-4 Front View Feed aceway Main Lugs or Main Breaker. Load Circuit " (3cm) minimum top and front Terminal Blocks for Load Circuits Class (PELV) GP8-4 Side View air flow " (3cm) minimum For maximum Feed and Wire Sizes, consult Overview page. Water damages Panels! Install Panels in a location where they will not get wet.

9 GAFIK Systems gp GP3 Mini Panel Overview 30 Volt (CE) Wire Sizes Power Feed: #8 AWG (.0mm ) to #4 AWG (5.0mm ) Neutral Feed: #4 AWG (.0mm ) to #6 AWG (0.0mm ) Dimmed Hot/Live: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Load Neutral: #4 AWG (.0mm ) to #6 AWG (0.0mm ) Control Typical Load Circuit Bypass Jumpers - Do Not emove DL SL L DL SL L DL 3 SL 3 L 3 Branch Circuit Breakers Load Terminal Block Dimmed Hot/Live Load Neutral Ground Tips Wire the GP3 similar to wiring a lighting Distribution Panel: un feed and load wiring. No other wiring or assembly required. Common Neutrals are not permitted. un separate Neutrals for each load circuit. The GP3 can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Use Branch Circuit Breakers to switch lights on and off. Neutral Feed Power Feed (Hot/Live)

10 GAFIK Systems gp GP4 Mini Panel Overview 30 Volt (CE) Wire Sizes Power Feed: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Neutral Feed: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Dimmed Hot/Live: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Load Neutral: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Typical Dimming Leg Bypass Jumpers - Do Not emove DL SL L N N DL SL L N N Dimmed Hot/Live Load Tips Wire the GP4 similar to wiring a lighting Distribution Panel: un feed and load wiring. No other wiring or assembly required. Common Neutrals are not permitted. un separate Neutrals for each load circuit. The GP4 can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Load Neutral Terminal Block Power Feed (Hot/Live) Ground Neutral Feed

11 GAFIK Systems gp GP8-4 Standard-Size Panel Overview 30 Volt (CE) Wire Sizes Power Feed: #4 AWG (.0mm ) to #4 AWG (5.0mm ) Neutral Feed: #4 AWG (.0mm ) to #4 AWG (5.0mm ) Dimmed Hot/Live: #4 AWG (.0mm ) to #6 AWG (0.0mm ) Load Neutral: #4 AWG (.0mm ) to #0 AWG (4.0mm ) Typical Load Circuit Dimmed Live Load Neutral Load Feed Power Feed (Hot/Live) Neutral Feed DL SL L N DL SL L N Bypass Jumpers - Do Not emove Terminal Block Tips Wire the GP8-4 similar to wiring a lighting Distribution Panel: un feed and load wiring. No other wiring or assembly required. Common Neutrals are not permitted. un separate Neutrals for each load circuit. The GP8-4 can provide temporary lighting: Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Use Branch Circuit Breakers to switch lights on and off. Branch Circuit Breakers Class (PELV)

12 GAFIK Systems 30V (CE) Load Circuits (GP3-4) gp All Load Types except Fluorescent Dimming Ballasts GP Dimming Panel Dimmed Live Neutral DL SL L N Load Use the Dimmed Live (DL) for all Non-Dim Load Types. All Load Circuit #4 AWG (.0mm ) to #0 AWG (4.0mm ) Load Terminals Bypass Jumpers - Do Not emove Consult Overview page for appropriate Neutral location.

13 GAFIK Systems GP w/ GX-TVM Overview for 0-0V, DSI, and DALI Load Types - 30 Volt (CE) Panels gp DL = Dimmed Live L = Live N = Neutral DL L N DL L N L N Load + + +

14 GAFIK Systems gp Low-Voltage Class (PELV) (All Models) System communications use low-voltage Class wiring. must be daisy-chained. must run separately from line (mains) voltage. GAFIK Eye 4000 System Class (PELV) wiring link requires: Two # AWG (.5mm ) conductors for control power. One twisted, shielded pair of #8 AWG (.0mm ) for data link. One #8 AWG (.0mm ) conductor for Emergency (Essential) sense line, from panel to panel. Total length of Control Link may be no more than,000 ft. (60m). Approved low-voltage cable is available from Lutron, Belden, and Liberty. These are approved with # AWG data link wires. Dimming Panel Control Interface Control Unit Wallstations GAFIK 5000TM/6000 /7000 System Class (PELV) wiring link requires: Two # AWG (.5mm ) conductors for control power. One twisted, shielded pair of #8 AWG (.0mm ) for data link. One #8 AWG (.0mm ) conductor for emergency (essential) sense line, from panel to panel. Total length of Control Link may be no more than,000 ft. (600m). If -PT interface and GX-CBL-46L cable is used, length may be up to 4,000 ft. (00m). Dimming Panel Processor Panel Control Interface Control Unit Wallstations Power Panel Link efer to GAFIK 5000/6000/7000 Specification GX-CBL-46L Class (PELV) wiring cable is available from Lutron and contains: Two # AWG (.5mm) conductors for control power. One twisted, shielded pair of # AWG (0.65mm) for data link. One #8 AWG (.0mm) conductor for emergency (essential) sense line.

15 GAFIK Systems gp Class (PELV) Panel-to-Panel (All Models) To additional Power Panels 3,4 5 Control () # AWG (.5 mm ) : Common : 4VFW Data Link () shielded, twisted pair #8 AWG(.0 mm ) 3: 4: () #8 AWG (.0 mm ) 5: Sense Line Shield/Drain 3,4 To Lighting Controls or Processors 3 4 D D 5 Common +4VFW Drain Sense Data A OK Power Data B OK Link A Link B Common 3 4 D 5 C D SELECT CICUIT Drain Common +4VFW Drain Sense Data A OK Power Data B OK Link A Link B Common 3 4 D 5 C D SELECT CICUIT Drain Circuit Circuit Dimming Panel Dimming Panel Notes: Emergency Power: The additional #8 AWG (.0mm ) wire is a sense line from terminal 5 of another Panel. This sense line allows an Emergency (Essential) Lighting Panel to sense when Normal (Non-Essential) power is lost. If more than one Emergency Lighting Panel needs to sense from a specific Normal Panel, a dedicated wire between each pair of Normal (Non- Essential) and Emergency (Essential) panels may be required. Shield/Drain: Connect shielding as shown. Do not connect to Ground (Earth) or circuit board of Circuit Selector. Connect the bare drain wires and cut off the outside shield. (4) # AWG (.5 mm ) 3 4 D 5 Class (PELV) Terminal Connections Each low-voltage Class (PELV) terminal can accept only two #8 AWG (.0mm ) wires. Two # AWG (.5mm ) conductors will not fit. Connect as shown using appropriate wire connectors. 4VFW A OK Drain Sense A Power 3 4 D 5 B C Drain D

16 GAFIK Systems gp Option Delta Power Branch Circuit Protection Lutron Ten Volt Module (TVM) Locking Cover LinkTM Description Panel accepts Delta power feed (phase to phase). Available for 40 V only. Limited to, -pole circuits. Branch Circuit Breakers with higher AIC ratings or special breaker types such as: ELB (Earth Leakage Breaker - 30 V CE/40 V non-ce Only). CD (esidual Current Device - 30 V CE/40 V non-ce Only). Allows panel to operate fluorescent ballasts that meet IEC 99 standards for 0-0V control including: Lutron s TVE ballasts 0-0V neon PWM fluorescent Tridonic DSI (Digital Serial Interface). The TVM can sink or source 5OmA (typically 5-50 ballasts) on each circuit. Prevents accidental switching of circuit breakers. Adds an additional.5 (57.mm) to the front of panel. Available for GP8-GP4 only Allows a DMX5 theatrical console to operate the load circuits in the dimming panel. Allows a GAFIK Eye 4000 System to handle 8 zones (two links of 64 zones). Allows two GAFIK Eye 4000 Systems to share the same dimming panel. Application Areas with Delta power. Jobs with fluorescent ballasts that require 0-0V, PWM, or DSI control. Service corridors and public areas. Control of architectural lighting from a DMX5 theatrical console is required. A mix of architectural and theatrical lighting exists on the job. Multiple systems where space for panels is limited. Tridonic is a registered trademark of Zumtobel AG.

LP Dimming Panels. GRAFIK Systems

LP Dimming Panels. GRAFIK Systems GAFIK Systems lp-1 12.8.03 are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Work directly with incandescent, magnetic low voltage,

More information

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL rev gp-a 7.0.00 GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available

More information

GP Dimming Panels 230 Volt (CE)

GP Dimming Panels 230 Volt (CE) 30 Volt (CE).3.08 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim. Models available with:

More information

LCP128T Spec Grade Dimming System

LCP128T Spec Grade Dimming System LCP128T Spec Grade Dimming System 369-642a 1 06.04.12 System Overview LCP128T is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels

More information

Phase-Adaptive Power Module

Phase-Adaptive Power Module GAFIK Eye papm-1 3.12.08 Description Provides capability for a zone on a GAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic

More information

3-Wire Fluorescent Power Module

3-Wire Fluorescent Power Module 369355 Rev B 1 09.02.11 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to dim fluorescent lights that have Lutron Hi-lumeR and Eco-10R (Eco Series) line-voltage

More information

Phase-Adaptive Power Module with 3-Wire Fluorescent Input

Phase-Adaptive Power Module with 3-Wire Fluorescent Input 369-358c 1 03.19.12 Description When connected to a 20 A circuit breaker, provides capacity on a 3-wire fluorescent dimmer for a full 16 A load of lighting. May be used to dim incandescent, halogen, electronic

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

DIN Rail Power Module

DIN Rail Power Module 800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A www.lutron.com +44.(0)20.7702.0657 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller DIN Rail odule The DIN Rail odule family

More information

DIN Power Module - Phase Adaptive

DIN Power Module - Phase Adaptive DI Power Module ow Capacity Phase Adaptive DI Power Module - Phase Adaptive 369849d 1 07.29.16 The Phase Adaptive Power Module family is a group of modular products for the control of lighting loads. This

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

Phase-Adaptive Power Module

Phase-Adaptive Power Module Phase-Adaptive Power Module Provides dimming control for 1 zone of a full 16 A lighting load. May be used to dim incandescent, halogen, electronic low-voltage, magnetic low-voltage, neon/cold cathode.

More information

Wired Vareo Local Lighting Controls

Wired Vareo Local Lighting Controls Wired Vareo Local Lighting Controls 8 Series Local Lighting Controls D48 Bus Architectural-Style L o c a l l i g h t i n g c o n t r o l s Wired Vareo local lighting controls function much like standard

More information

Wired Maestro Local Controls

Wired Maestro Local Controls Wired Maestro Local Controls 4 Series / 8 Series Local Controls H48 Bus Designer-Style L O C A L c o n t r o l s Wired Maestro local controls function much like standard dimmers and switches, but can be

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3

More information

Switching Power Module

Switching Power Module 369357d 1 06.20.13 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic

More information

Installation & User Instructions

Installation & User Instructions Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.

More information

ALD Dimmer Enclosures

ALD Dimmer Enclosures ALD Enclosures FEATURES Attractive crinkle black finish. er Connection Power Supply Neutral Taps Modules (not included) Cooling Fans Dimming Electronics (not included) Available in 2 sizes: ALD6 (6 dimmer

More information

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A) TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29132-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the

More information

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface Lutron Power Interfaces Ten Volt Interface 36947d 07.07.4 Features 00-77 V~ forward, reverse, and center phase control input capability Provides control and switching capabilities to switch and dim current

More information

INSTALLATION. **Microprocessor Status LED:

INSTALLATION. **Microprocessor Status LED: INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East Orem, Utah 84097 Telephone 801 229 2800 Fax 801 224 0355 Standard Dimmer Module MODEL: SDM12-EM Overview The SDM12 dimmer module

More information

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A) TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user

More information

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface Lutron Power Interfaces Ten Volt Interface 369247e 1 07.07.16 Features 100-277 V~ forward, reverse, and center phase control input capability Provides control and switching capabilities to switch and dim

More information

GRX-TVI Ten Volt Interface

GRX-TVI Ten Volt Interface Lutron Power Interfaces Ten Volt Interface 369247c 1 09.17.13 Features 100-277 V~ forward, reverse, and center phase control input capability Provides 0-10 V- control and switching capabilities to switch

More information

Controls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES

Controls.   CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES SPECIFICATION SUBMITTAL s The contractor s choice in rugged, linear slide dimmers. www.lutron.com/nova CONTROLS AND ACCESSORIES Slide-to-Off s Preset s Select light level with slider; slide down to off

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

EcoSystemR Multiple Control Input Ballasts

EcoSystemR Multiple Control Input Ballasts EcoR Multiple Control s 369454h 1 09.15.14 Digital electronic dimming ballasts maximize the benefits of a lighting management system. EcoR s offer 100% to 10% dimming; ideal for use where saving energy,

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Five Control Digital Dimming s Eco Multiple Control s 369454l 1 09.02.16 Digital electronic dimming ballasts maximize the benefits of a lighting management system. Eco s offer 100% to 10% dimming;

More information

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323

More information

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron bus supplies (Eco-10 and Hi-lume

More information

HomeWorksR QS Wired MaestroR Architectural Local Controls

HomeWorksR QS Wired MaestroR Architectural Local Controls HomeWorks QS Wired Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where

More information

Maestro Wireless Dimmers and Switches

Maestro Wireless Dimmers and Switches Maestro Wireless Dimmers and The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers energy savings,

More information

SO-SVCN- - GRAFIK Systems Sivoia QEDTM Controller

SO-SVCN- - GRAFIK Systems Sivoia QEDTM Controller N- - Sivoia QEDTM Controller N-WH-E01 Color and Finish Codes LEDs I-WH- (Insert version) Engraving so-svc-1 10.20.07 Description Provides programming and control of one group of Sivoia QEDTM Window Treatments.

More information

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 EC3DT4MWKU1S 26/32W T4 1LMP Ba Lutron Catalog Number Manufacturer Description Weight per unit Product Category EC3DT4MWKU1S

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase. Installation Instructions Please Leave for Occupant HP-2, HP-4, & HP-6 Dimming Module 120/277VAC, 60Hz Description Dimming Module HP-2 2000W/VA 16A@120/277V 60Hz Listed Industrial Equipment 243C Dimming

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. Power Switching Introduction CRESTRON GREEN LIGHT power switching cabinets come pre-configured with GLXP modules already installed. The cabinets only require installation and wiring of feed and load circuits.

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming Hi-lume LED Overview Hi-lume LED 1 12.11.9 Hi-lume LED is a high-performance, constant current driver that provides energy-efficient dimming for LED lighting. With industry-leading full-range % to 1% dimming,

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

Elegance Electrician s Installation Guide

Elegance Electrician s Installation Guide Elegance Electrician s Installation Guide CentraLite Systems, Inc. 6420 Wall St. Mobile, AL 36695 Phone: 877-466-5483 Fax: 251-607-9119 2003-2005 CentraLite Systems, Inc. Revised 10/20/2005 ELECTRICIAN

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Maestro Wireless Dimmers and Switches

Maestro Wireless Dimmers and Switches Maestro Wireless Dimmers and Switches The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers energy

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! Description. System Specifications. Installation Instructions Occupant Copy

4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! Description. System Specifications. Installation Instructions Occupant Copy Installation Instructions Occupant Copy 4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! The GRXSLD Control Units are designed for residential or commercial applications indoor use

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC T8 c PC BASIC sl, 4 28 W PC BASIC Product description CELMA Energy Efficiency Index A2 / A3 Nominal life-time up to 50,000 h (at max. ta with a failure rate max. 0.2 % per 1,000 h) Large temperature range

More information

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts TVE Overview Eco-0TM TVETM 0% TVE () 02.9.04 The (Eco-0) TVE is a 0% fluorescent dimming ballast for applications using a 0-0V control. TVE ballasts are also designed to work seamlessly with 0-0V lighting

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

AXA DALI P20. DALI Broadcast Controller. Installation Manual

AXA DALI P20. DALI Broadcast Controller. Installation Manual AXA DALI P20 DALI Broadcast Controller Installation Manual THE DALI P20 MUST BE INSTALLED BY A LICENSED ELECTRICIAN IMPORTANT INFORMATION ELECTRICIANS MUST READ PRIOR TO INSTALLATION 1) This product must

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number 0-10V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V 4 circuit Analog 1-10V 4 x 4 A. Dimmer pack Serial Number Dimmers Indicators Digital Lighting Systems,Inc Info@digitallighting.com

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

GP12 TECHNICAL MANUAL

GP12 TECHNICAL MANUAL GP12 D i g i t a l l y C o n t r o l l e d D i m m e r R a c k TECHNICAL MANUAL Contents i Table of Contents Table of Contents... i 1.0 Introduction... 1-1 2.0 Equipment Description... 2-1 2.1 Front panel

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Vive Maestro Wireless Dimmers and Switches

Vive Maestro Wireless Dimmers and Switches Vive Maestro Wireless Dimmers and Switches The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers

More information

Number 9 January SECTION 1 Dimming of T12 Fluorescent lamps 2. SECTION 2 Dimming of T8 Fluorescent lamps 4. SECTION 3 Do's and Don'ts 6

Number 9 January SECTION 1 Dimming of T12 Fluorescent lamps 2. SECTION 2 Dimming of T8 Fluorescent lamps 4. SECTION 3 Do's and Don'ts 6 FACT sheet Number 9 January 1993 A GUIDE TO FLUORESCENT DIMMING E nsuring good quality fluorescent dimming calls for more than simply using a 'fluorescent' type of dimmer. Many other factors need consideration,

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,

More information

EcoSystemT 5-Series LED Driver ( V~, CE)

EcoSystemT 5-Series LED Driver ( V~, CE) EcoSystemT 5-Series LED Driver (220-240 V~, CE) EcoSystemT 5-Series LED Drivers provide a high performance solution for any space in any application, while providing smooth, continuous dimming down to

More information

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz

Installation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz Installation Instructions Please Read Before Installing Overview The HD-RD and the HD-RS Switch are for use with HomeWorks Maestro s and Switches. Up to nine HD-RD s may be used with a HomeWorks Wired

More information

CTRC Series Flexible Rogowski Current Transformer - Installation Guide

CTRC Series Flexible Rogowski Current Transformer - Installation Guide and industrial control equipment to measure the current on branch circuits and feeders. CTRC Series Flexible Rogowski Current Transformer - Installation Guide 1 CTRC Models Models in bold are stock items.

More information

P90L-ISO6MB & ISO10MB

P90L-ISO6MB & ISO10MB P90L-ISO6MB & ISO10MB for 6kVA, 10kVA Models User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 9/23/14) Table of Contents Important Safety Instructions...3 An Important Notice...3

More information

QS Motor Group Controller QSE-CI-4M-D 4-Output AC Motor Controller. Energi Savr NodeTM Unit. seetouchr QS Wallstation. Wireless Communication

QS Motor Group Controller QSE-CI-4M-D 4-Output AC Motor Controller. Energi Savr NodeTM Unit. seetouchr QS Wallstation. Wireless Communication LUTRON LUTRON R Motor Grop Controller E-CI-4M-D 4-Otpt AC Motor Controller Motor Grop Controller The motor grop controller is an interface that provides seamless integration of Qantm and stand-alone systems

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371 Sunburst SB2400 Dimmer Rack and Receiver 86(50$18$/ Version 1.02 P/N F371 Copyright 2004 Lehigh Electric Products Co. Revised January 2006 TECHNICAL INQUIRY The dimming system consists of electrical and

More information

Bulletin 871P Can Sensors

Bulletin 871P Can Sensors Bulletin 871P Can Sensors Description Bulletin 871P inductive proximity can sensors are self-contained solid state devices, designed specifically for sensing size 202 to 704 metal cans without physical

More information

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Residential Systems Control of LED Lighting (120V)

Residential Systems Control of LED Lighting (120V) Residential Systems Control of LED Lighting (120V) 1.0 Overview Light Emitting Diode (LED) lighting is becoming more prevalent in the marketplace and is often being implemented in residences in place of

More information

2.7. IT system floor-standing distribution cabinet Series -IPS-F

2.7. IT system floor-standing distribution cabinet Series -IPS-F Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 07-0 Fax: 0640 07-25 IT system floor-standing distribution cabinet Series -IPS-F for supplying power to medical locations

More information

Installation Instructions

Installation Instructions ADFE-A Three-Wire Fluorescent Multi-way Architectural Dimmer SPECIFICATIONS Dimming slider On/Off switch Label slot Voltage...2VAC, Hz Maximum Load Rating... A Minimum Load Rating....33A Narrow Dimmer:

More information

Midwest Dry Type Transformers

Midwest Dry Type Transformers Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase

More information

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming CONSTANT VOLTAGE POWER SUPPLIES CONSTANT VOLTAGE New dimming drivers are compatible with most wall dimmers for 10-100% light control. For non-dimming applications or for use with AL-PWM-6A, use LED-DR

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

AIR COOLED RECTIFIER SPECIFICATION S-50-A

AIR COOLED RECTIFIER SPECIFICATION S-50-A SPECIFICATIONS AIR COOLED RECTIFIER Spec50a1 5JAN1999 SPECIFICATION S-50-A HIGH VOLTAGE SINGLE TRANSFORMER AIR COOLED RECTIFIER Standard output power range: 250 to 600 volts at 100 to 1,200 amperes TECHNICAL

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

K25000 & KD25000 Series

K25000 & KD25000 Series K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

Wiring Diagram Index. Find product, model #, and wiring diagram # Then find wiring diagrams on pgs

Wiring Diagram Index. Find product, model #, and wiring diagram # Then find wiring diagrams on pgs Wiring Diagram Index Find product, model #, and wiring diagram # Then find wiring diagrams on pgs.06-7 Architectural Diagram # Accessories NTR-5-6 NTR-5-GFCI- 7 NTR-5-IG-OR- 6 NTR-0-6 NTR-0-GFCI- 7 NTR-0-IG-OR-

More information

HomeWorks QS Designer RF Maestro Local Controls

HomeWorks QS Designer RF Maestro Local Controls HomeWorks QS RF Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be followed

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

Compact SE Overview. High-Performance Dimming. Ballast

Compact SE Overview. High-Performance Dimming. Ballast Compact SE Overview CompactSE 01.10.10 For designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your solution.

More information

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps 3-Wire Control, 220/240 Volt T-8 Linear, rev hi-220-240-1b 1.10.02 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) HOT DIMMED HOT NEUTRAL Hi-lume Power Control Dimming Ballast Lamps DESCRIPTION Continuous,

More information