SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT

Size: px
Start display at page:

Download "SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT"

Transcription

1 136 SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT

2 Extraction kits for testing centres for cars, light commercial vehicles and heavy vehicles with manual or automatic return system Equipments 137

3 EXTRACTION KITS FOR VEHICLE TESTING CENTRES VERSIONS AVAILABLE IN ALL DIAMETERS FOR ALL APPLICATIONS ø 75 REV-KIT M DUCT WITH MANUAL RETURN SYSTEM ø 100 ø 100 REV-KIT A DUCT WITH AUTOMATIC RETURN SYSTEM ø 125 ø 150 ø

4 Equipments REV-KIT M REV-KIT A APPLICATIONS The system is specifically designed for the extraction of the exhaust gas from moving vehicles during the various stages of the vehicle test envisaged by EEC regulations concerning road safety and the environment. Installed on a ceiling or wall, in the lengths required for various different vehicle testing lines, this system allows extraction of exhaust gas by connecting a special rubber intake directly to the vehicle exhaust pipe. The extraction unit, equipped with a fixing clamp on the vehicle exhaust adaptor, is caused to travel along the entire length of the extraction system to provide localised removal of exhaust gas. At the end of the line, a mechanical release device automatically detaches the hose adapted to release the vehicle from the system. In the REV M version the operator manually returns the slide bearing to the start of the line, where it remains at the disposal of the next vehicle, while in version REV A a specific recovery system with a steel cable serves to return the slide bearing automatically to the start of the line so that the intake can be connected to the next vehicle. Version REV A uses inverter technology to adjust the return speed of the slide bearing, which is set during the system testing phase, in accordance with the length of the line. For control and supervision of all the functions (especially safety functions), version REV A is equipped as standard with both a pendant panel and a remote control handset. CONSTRUCTION FEATURES The CEA duct track is made entirely of aluminium alloy to guarantee properties of low weight and resistance to the chemical components contained in exhaust gas. The duct cover supported by preassembled brackets in powder coated carbon steel allows the creation of very long suction lines resistant to torsional loads. The system envisages the use of a double die cast profile in Anticorodal aluminium alloy specifically designed to allow fast and easy sliding movements of hose reels and slide bearings for connection to TGA rubber hoses. The perfect internal vacuum seal required by high pressure hose reels for exhaust gas extraction is assured by a special EPDM rubber lip seal made with a fin profile and designed to provide durable resistance to aggressive exhaust gas components, heat, aging and abrasion. Ceiling or wall mounting procedures are greatly simplified by the use of our range of telescopic brackets, which can be used for installation also at significant heights and for ensuring perfect alignment of the extraction duct. 139

5 DUCT SYSTEMS FOR VEHICLE TEST CENTRES REV-KIT M The system is specifically designed for the extraction of the exhaust gas from moving vehicles during the various stages of the vehicle test envisaged by EEC regulations concerning road safety and the environment. Installed on a ceiling or wall, in the lengths required for various different vehicle testing lines, this system allows extraction of exhaust gas by connecting a special rubber intake directly to the vehicle exhaust pipe. The extraction unit, equipped with a fixing clamp on the vehicle exhaust adaptor, is caused to travel along the entire length of the extraction system to provide localised removal of exhaust gas. At the end of the line a mechanical release device automatically frees the vehicle, in the REV M version the operator manually returns the slide bearing to the start of the line, where it will be available for the next use. REV-KIT M WITHOUT EXTRACTOR FAN DIMENSIONS MAX. RECOMMENDED AIRFLOW CAPACITY PRESSURE DROP TOT. WEIGHT A x b x L mm m 3 /h Pa Kg CA 22/2 220 x 200 x CA 22/4 220 x 200 x CA 24/2 220 x 400 x CA 24/4 220 x 400 x The internal air velocity in the duct is calculated at approximately 20 m/sec. We recommend this value for the maximum air velocity to facilitate free sliding of the slide bearings and correct expulsion of exhaust gas. The data are guaranteed also for different lengths of TGA hose. The quoted performance data were measured using suitable instruments in our laboratories. airflow capacity and available pressure: these values are referred to the use of extractor fans coupled directly to the duct in standard working conditions; expulsion lines: expulsion lines must be created using rigid ducting avoiding cross-section reductions, cross-section changes, bends and branches and with extended length noise level: noise data were measured in free-field conditions in indoor installations. In low noise impact surroundings the use of silencers is recommended. 140

6 PRECONFIGURED KITS WITH SINGLE SUCTION, AVAILABLE WITH VA SERIES ALUMINIUM EXTRACTOR FAN Equipments A C A LIST OF MAIN COMPONENTS IN PRECONFIGURED KIT Aluminium duct track F B B C Single slide bearing for TGA hose Balancer pulley complete with bracket for slide bearing and band D TGA rubber hose L = 7.5 m D E BGN rubber intake F VA extractor fan E REV-KIT M DUCT SELECTION TABLE WITH INDICATION OF DIAMETERS FOR EXPULSION EXTRACTOR FAN FR EXTRACTOR FAN OUTLET CONNECTION RR DUCT OUTLET DIAMETER Ø mm KW / HP Ø mm Ø mm REV-KIT M Ø 075 REV-KIT M Ø 100 VA 30 Kw / HP 0.55 / 0.75 Ø 100/120 Ø 120 REV-KIT M Ø 150 VA 35 Kw / HP 1.1/ 1.5 Ø 130/180 Ø 180 N.B: all fittings and ducts feature a reinforced rim (RR) for fixing with collar. The outlet connection is equipped with flange (F) on the extractor fan fixing side and reinforced rim (R) on the other side. 141

7 PRECONFIGURED KITS WITH SINGLE SUCTION, AVAILABLE WITH VA SERIES ALUMINIUM EXTRACTOR FAN KIT-REV M Ø 75 KIT supplied pre-assembled and packed consisting of CA x 200 duct, VA kw 400 V 2-phase Hz B5 extractor fan, single slide bearing with MANUAL return, TGA rubber hosing and rubber intake with automatic release system. Excluding wall and ceiling brackets. REV M 8/75 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = 8000 mm Ø 75 mm RUBBER HOSING REV M 12/75 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = mm Ø 75 mm RUBBER HOSING REV M 16/75 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = mm Ø 75 mm RUBBER HOSING KIT-REV M Ø 100 KIT supplied pre-assembled and packed consisting of CA x 200 duct, VA kw 400 V 2-phase Hz B5 extractor fan, single slide bearing with MANUAL return, TGA rubber hosing and rubber intake with automatic release system. Excluding wall and ceiling brackets. REV M 8/100 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = 8000 mm Ø 100 mm RUBBER HOSING REV M 12/100 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = mm Ø 100 mm RUBBER HOSING REV M 16/100 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = 16OOO mm Ø 100 mm RUBBER HOSING 142

8 PRECONFIGURED KITS WITH SINGLE SUCTION, AVAILABLE WITH VA SERIES ALUMINIUM EXTRACTOR FAN Equipments KIT-REV M Ø 150 KIT supplied pre-assembled and packed consisting of CA x 200 duct, VA kw 400 V 2-phase Hz B5 extractor fan, single slide bearing with MANUAL return, TGA rubber hosing and rubber intake with automatic release system. Excluding wall and ceiling brackets. REV M 16/150 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = mm Ø 150 mm RUBBER HOSING REV M 20/150 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = mm Ø 150 mm RUBBER HOSING REV M 24/150 REV COMPLETE TEST KIT WITH MANUAL RETURN AND TGA L = mm Ø 150 mm RUBBER HOSING 143

9 WALL- AND CEILING-MOUNTED SYSTEMS WITH AUTOMATIC RETURN REV-KIT A The system is specifically designed for the extraction of the exhaust gas from moving vehicles during the various stages of the vehicle test envisaged by EEC regulations concerning road safety and the environment. Installed on a ceiling or wall, in the lengths required for various different vehicle testing lines, this system allows extraction of exhaust gas by connecting a special rubber intake directly to the vehicle exhaust pipe. The extraction unit, equipped with a fixing clamp on the vehicle exhaust adaptor, is caused to travel along the entire length of the extraction system to provide localised removal of exhaust gas. At the end of the line a mechanical release device automatically frees the vehicle; in the REV A version a specific recovery system with a steel cable automatically returns the slide bearing to the start of the line, where it remains at the disposal of the next vehicle. Version REV A uses inverter technology to adjust the return speed of the slide bearing, which is set during the system testing phase, in accordance with the length of the line. For control and supervision of all the functions (especially safety functions), version REV A is equipped as standard with both a pendant panel and a remote control handset. REV-KIT A WITHOUT EXTRACTOR FAN DIMENSIONS MAX. RECOMMENDED AIRFLOW CAPACITY PRESSURE DROP TOT. WEIGHT A x b x L mm m 3 /h Pa Kg CA 22/2 220 x 200 x CA 22/4 220 x 200 x CA 24/2 220 x 400 x CA 24/4 220 x 400 x The internal air velocity in the duct is calculated at approximately 20 m/sec. We recommend this value for the maximum air velocity to facilitate free sliding of the slide bearings and correct expulsion of exhaust gas. The data are guaranteed also for different lengths of TGA hose. The quoted performance data were measured using suitable instruments in our laboratories. airflow capacity and available pressure: these values are referred to the use of extractor fans coupled directly to the duct in standard working conditions; expulsion lines: expulsion lines must be created using rigid ducting avoiding cross-section reductions, cross-section changes, bends and branches and with extended length noise level: noise data were measured in free-field conditions in indoor installations. In low noise impact surroundings the use of silencers is recommended. 144

10 PRECONFIGURED KITS WITH SINGLE SUCTION, AVAILABLE WITH VA SERIES ALUMINIUM EXTRACTOR FAN G A Equipments F C LIST OF MAIN COMPONENTS IN PRECONFIGURED KIT B A Aluminium duct track B Single slide bearing for TGA hose C Balancer pulley complete with bracket for slide bearing and band D D E F G TGA rubber hose L = 7.5 m BGN rubber intake VA extractor fan Automatic return system E REV-KIT A DUCT SELECTION TABLE WITH INDICATION OF DIAMETERS FOR EXPULSION EXTRACTOR FAN FR EXTRACTOR FAN OUTLET CONNECTION RR DUCT OUTLET DIAMETER Ø mm KW / HP Ø mm Ø mm REV-KIT A Ø 075 REV-KIT A Ø 100 VA 30 Kw / HP 0.55 / 0.75 Ø 100/120 Ø 120 REV-KIT A Ø 150 VA 35 Kw / HP 1.1/ 1.5 Ø 130/180 Ø 180 N.B: all fittings and ducts feature a reinforced rim (RR) for fixing with collar. The outlet connection is equipped with flange (F) on the extractor fan fixing side and reinforced rim (R) on the other side. 145

11 PRECONFIGURED KITS WITH SINGLE SUCTION, AVAILABLE WITH VA SERIES ALUMINIUM EXTRACTOR FAN KIT-REV A Ø 75 KIT supplied pre-assembled and packed consisting of CA x 200 duct, VA kw 400 V 2-phase Hz B5 extractor fan, electrical panel for control of all the components installed. Excluding wall and ceiling brackets. REV A 8/75 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 75 mm RUBBER HOSE L = 8000 mm REV A 12/75 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGAØ 75 mm RUBBER HOSE L = mm REV A 16/75 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 75 mm RUBBER HOSE L = mm KIT-REV A Ø 100 KIT supplied pre-assembled and packed consisting of CA x 200 duct, VA kw 400 V 2-phase Hz B5 extractor fan, electrical panel for control of all the components installed. Excluding wall and ceiling brackets. REV A 8/100 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 100 mm RUBBER HOSE L = 8OOO mm REV A 12/100 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 100 mm RUBBER HOSE L = 12OOO mm REV A 16/100 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 100 mm RUBBER HOSE L = 16OOO mm 146

12 PRECONFIGURED KITS WITH SINGLE SUCTION, AVAILABLE WITH VA SERIES ALUMINIUM EXTRACTOR FAN Equipments KIT-REV A Ø 150 KIT supplied pre-assembled and packed consisting of CA x 200 duct, VA kw 400 V 2-phase Hz B5 extractor fan, electrical panel for control of all the components installed. Excluding wall and ceiling brackets. REV A 16/150 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 150 mm RUBBER HOSE L = 16OOO mm REV A 20/150 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 150 mm RUBBER HOSE L = 20OOO mm REV A 24/150 REV COMPLETE TEST KIT WITH AUTOMATIC RETURN AND TGA Ø 150 mm RUBBER HOSE L = 24OOO mm 147

13 REV KIT DUCT ACCESSORIES VA EXTRACTOR FAN Spark-proof. Centrifugal single suction fan made of aluminium with RAL 3000 red paint finish and impeller with radial blades. VA 30 VA 35 VA 40 VA EXTRACTOR FAN 30 KW 0.55 HP phase VA EXTRACTOR FAN 35 KW 1.1 HP phase VA EXTRACTOR FAN 40 KW 1.5 HP 2 3-phase ATS Duct support system ATS 1 75 ATS ATS ATS FITTING FOR SUSPENSION OF Ø 75 HOSE ON SLIDE BEARING FITTING FOR SUSPENSION OF Ø 100 HOSE ON SLIDE BEARING FITTING FOR SUSPENSION OF Ø 125 HOSE ON SLIDE BEARING FITTING FOR SUSPENSION OF Ø 150 HOSE ON SLIDE BEARING FC CLOSING FLANGE Extruded Ø 200 mm duct closing flange made of carbon steel with GREY RAL 7040 L paint finish FC 22 CA DUCT CLOSING FLANGE FC 24 CA DUCT CLOSING FLANGE FU OUTLET FLANGE Extruded Ø 200 mm duct outlet flange made of carbon steel with GREY RAL 7040 L paint finish FU 22 CA DUCT OUTLET FLANGE FU 24 CA DUCT OUTLET FLANGE SS SUPPORTING BRACKETS Kit of support brackets made of carbon steel with GREY RAL 7040 L paint finish SS 22 BRACKETS FOR CA 22 DUCT SS 24 BRACKETS FOR CA 24 DUCT 148

14 REV KIT DUCT ACCESSORIES Equipments SSR RAL 7040 L grey ceiling mounting bracket for REV A/M KIT SSR SSR L = 700 cm CEILING MOUNTING BRACKET L = 1500 cm CEILING MOUNTING BRACKET SPR RAL 7040 L grey REV A/M KIT wall mounting bracket SPR SPR WALL MOUNTING BRACKET L = 550 cm WALL MOUNTING BRACKET L = 960 cm CEILING MOUNTING BRACKET KIT 3000 Ceiling mounting bracket kit L = 3000 THE KIT INCLUDES ALL 45 BRACKETS, STRUCTURAL BRACKETS, SCREWS AND ASSEMBLY INSTRUCTIONS. THE STRUCTURE IS DESIGNED WITH A SUITABLE SAFETY COEFFICIENT (K). IL KIT È ADATTO PER ALTEZZE DA 500 mm A 3000 mm. SI CONSIGLIA L ADATTAMENTO DELLA STAFFA IN OPERA. BRACKET KIT FOR EXTRACTOR FAN VA30 / VA 40 Bracket made of carbon steel with RAL 7040 L grey paint finish. THE BRACKET IS ALREADY PRESENT IN PRECONFIGURED KITS. 149

15 REV KIT DUCT ACCESSORIES HOSE CLAMPS Galvanised steel hose clamps to DIN 3017 Suitable for use with all hoses and does not cause surface damage Ø 75 mm galvanised steel hose clamp Size: mm Ø 100 mm galvanised steel hose clamp Size: mm Ø 125 mm galvanised steel hose clamp Size: mm Ø 150 mm galvanised steel hose clamp Size: mm CLAMP COVERS Clamp covers in silicone rubber to protect against scratches and injury Ø 75 mm rubber clamp cover Ø 100 mm rubber clamp cover Ø 125 mm rubber clamp cover Ø 150 mm rubber clamp cover ELECTRICAL PANEL FOR VA Electrical panel for extractor fan starting and thermal-magnetic protection ELECTRICAL PANEL FOR VA 30 KW 0.55 HP phase ELECTRICAL PANEL FOR VA 35 KW 1.1 HP phase ELECTRICAL PANEL FOR VA 40 KW 1.5 HP 2 3-phase 150

16 REV KIT DUCT ACCESSORIES Equipments RC EXTRACTOR FAN For use in suspended or outdoor applications SEE PAGE 270 N.B.: Consult VTL chapter in RC section BALANCER PULLEYS Balancer pulley complete with bracket for CST carriage, with RAL 3000 RED paint finish, nylon cord L= 10 m and 360 rotation UNIVERSAL BALANCER PULLEY FOR ALL CST SLIDE BEARINGS AND ALL AVAILABLE DIAMETERS, WITH 360 ROTATION. ADHESIVE TAPE AND SILICONE SEALANT Black adhesive tape 50 mm wide 25 m length for joining cover under cover strip SILICONE SEALANT AND BLACK ADHESIVE TAPE TO SEAL DUCT JOINTS ALREADY PRESENT IN PRECONFIGURED KITS. 151

FILTER MODULES FILTER MODULES APPLICATIONS

FILTER MODULES FILTER MODULES APPLICATIONS FILTER MODULES FILTER MODULES APPLICATIONS MF MF filter modules were developed for use as filtration systems in centralised systems or individual work stations for the extraction of welding fumes. They

More information

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)

AFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0) AFA TS GmbH - Werner von Siemens Str.3 - D-72661 Grafenberg Copyright 2009 Tel.: +49(0)7123-97382-0 - Fax: +49(0)7123-97382-90 - E-Mail: mail@afa-ts.de Page 1-15 www.afa-ts.com Exhaust Extraction Systems

More information

STANDARD VENTILATION UNIT (VK)

STANDARD VENTILATION UNIT (VK) VENTILATION TECHNIQUE STANDARD VENTILATION UNIT (VK) Air intake and/or air extraction Flexible, adaptable for every (existing) situation Can be combined with terminal boxes, type DK Models suitable for

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

INDUSTRY COMBO MF. Combined filter modules for fumes and particulate, combined composition of multiple modules to increase filtering capacity

INDUSTRY COMBO MF. Combined filter modules for fumes and particulate, combined composition of multiple modules to increase filtering capacity INDUSTRY Technical data sheet FILTER MODULES COMBO MF Combined filter modules for fumes and particulate, combined composition of multiple modules to increase filtering capacity APPLICATIONS The COMBO MF

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

Extraction arm FX100 Original

Extraction arm FX100 Original Bench top extraction systems for all environments. The Nederman bench top systems can be used in every type of environment, from assembly stations, where soldering fumes are extracted, to laboratories,

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

Exhaust Extraction Systems for Stationary Vehicles

Exhaust Extraction Systems for Stationary Vehicles Exhaust Extraction Systems for Stationary Vehicles The systems presented in this section are used for extracting exhaust from parked vehicles. All solutions offer simple installation and optimal extraction

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

Export Pricelist. Extraction rail type AS Exhaust rail, pipe connections. Extraction rail type AS Exhaust rail, Pipe Connections

Export Pricelist. Extraction rail type AS Exhaust rail, pipe connections. Extraction rail type AS Exhaust rail, Pipe Connections Export Pricelist Extraction rail type AS 175 2 Exhaust rail, pipe connections Extraction rail type AS 290 3 Exhaust rail, Pipe Connections Extraction rail type AS 440 4 Exhaust Rail, Pipe Connections Assembly

More information

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

ARTICULATED EXTRACTION ARMS ARMOFLEX ARMOTECH 03-05 06-08 PORTABLE UNITS PORTABLE EXTRACTION UNIT FACILE 26-28 IBS PAB 09-11 12-13 PORTABLE UNITS AER 101 AER 102 29-30 31-32 WALL-MOUNTED PURIFICATION SYSTEM

More information

INDEX. Chapter3. air master. Linear Bar Grilles

INDEX. Chapter3. air master. Linear Bar Grilles Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:

More information

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications. EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)

More information

CASED 24 Designed for emergency ventilation of hot fire smoke applications 300 C or 400 C for two hours operation, CE marked to EN12101-3 2002 All casings are hot dipped galvanised Sizes from 315mm to

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

SMART Application Structure Acoustics s n fa f o o R

SMART Application Structure Acoustics s n fa f o o R Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature +60 C, and dustiness not exceeding 0,3 g/m³, without viscous,

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation

The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation The is quiet even at high outputs, making it a discreet and effective heater for almost any situation A selection of grilles and finishes are available. Installation is simple and hassle-free due to the

More information

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:

More information

GTK 80. Technical data

GTK 80. Technical data Industrial square suspension system with open cable duct for heavy loads Modular construction with free accessible cable duct Floor, top-mounting or wall exit options Technical data Material: connecting

More information

[Small diaphragm vacuum pumps]

[Small diaphragm vacuum pumps] [Small diaphragm vacuum ] The small vacuum shown on this page produce vacuum using a diaphragm. They can be used either as vacuum pump or as a small compressor, and they are able to deliver 100% oil-free

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

Exhaust rail system 920 for stationary vehicles

Exhaust rail system 920 for stationary vehicles Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

B SERIES. Helical bevel Gear Reducers

B SERIES. Helical bevel Gear Reducers Helical bevel Gear Reducers FEATURES The technological content of -Series gear reducers allows for an extraordinary performance/lifespan ratio. These highly versatile gear units are successfully used in

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

RADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES...

RADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES... RADIAL STEEL HIGH PRESSURE RHD 5/10... 2 RHD 4/20... 3 RHD 8/25... 4 RHD 11/40... 5 RHD 9/60... 6 RHD 13/90... 7 CAS... 8... 14 ACCESSORIES... 18 1 RHD 5/10 A 230 / B 335 / C 385 / D 130 / E 140 / F 360

More information

Exhaust rail system 920 for stationary vehicles

Exhaust rail system 920 for stationary vehicles Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several

More information

Novenco Tunnel Fans. Novax October 2007

Novenco Tunnel Fans. Novax October 2007 Novenco Tunnel Fans Novax October 2007 Product facts Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC and AUR) and

More information

ABOUT KJN ALUMINIUM PROFILES

ABOUT KJN ALUMINIUM PROFILES P R O D U C T C ATA L O G U E ABOUT KJN ALUMINIUM PROFILES Our range of Aluminum Profile is available in a large range of sizes starting with 20 x 20 through to 100 x 200 making it suitable to use in all

More information

TECHNICAL APPLICATIONS. Metalpak Sb200

TECHNICAL APPLICATIONS. Metalpak Sb200 TECHNICAL APPLICATIONS Metalpak Sb200 Metalpak is a sun blind with slats which can be packed and adjusted, at the very cutting edge in terms of sturdiness and design. Used outside a building, it stands

More information

NCF 60 Hz. Protection class IP 55

NCF 60 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

Round duct diffuser DBB-RR

Round duct diffuser DBB-RR Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

Bench Top Extraction Arms

Bench Top Extraction Arms Bench Top Extraction Arms The Nederman BenchTop arms can be used in every type of environment, ranging from assembly stations, where solder fumes are extracted, to laboratories, where protection against

More information

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com PRODUCT BROCHURE Rectangular Displacement Diffuser RDW-FD smartemp.com DESCRIPTION The SMARTEMP Rectangular Displacement Diffuser, type RDW-FD (figure 1), produces a low velocity horizontal airflow pattern

More information

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation

More information

LINEAR SLOT DIFFUSERS

LINEAR SLOT DIFFUSERS LINEAR SLOT DIFFUSERS MODEL CD Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk - www.jprservices.co.uk

More information

Product & Description Order Code Dimensions (mm)

Product & Description Order Code Dimensions (mm) 1RD 100 X 350MM Ø100 L 350 1RD 100 X 1M Ø100 L 1000 Rigid Ducting PVC 1RD 100 X 2M Ø100 L 2000 1.0 2.8 6.2 1RD 100 X 3M Ø100 L 3000 1RD 125 X 350MM Ø125 L 350 1RD 125 X 2M Ø125 L 2000 0.4 1.4 3.8 1RD 150

More information

JdB cassette. Version 1.03 Sun Protection AVZ 3J.1

JdB cassette. Version 1.03 Sun Protection AVZ 3J.1 Version 1.0 Sun Protection AVZ J.1 J.2 Sun Protection AVZ Version 1.0 4211 424-000 Alu wall bracket JdB 95 mm Mill finish 4211 424-006 Idem RAL 9010 pure white 4211 424-755 Idem (* = Textured) RAL 7016

More information

INDEX. Chapter2. air master. Grilles and Registers

INDEX. Chapter2. air master. Grilles and Registers Chapter2 INDEX A.Grilles and registers. 1. Supply air grille - front horizontal blades...: ASG-H...2.1 2. Supply air grille - front vertical blades...: ASG-V...2.2 3. Supply air register - front horizontal

More information

Medium Pressure Centrifugal Fans

Medium Pressure Centrifugal Fans Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock

More information

Small centrifugal fans made of plastic

Small centrifugal fans made of plastic Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18

More information

400mm - 630mm diameter Volume flow up to 7.2m 3 /s ASED 42 Static pressures up to 1000 Pa High energy efficiency All casings are hot dipped galvanised Low installed noise levels protection IP55 Overheat

More information

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE Translation of the original document N 20033, 03.2015 Drycoolers Use Drycoolers in this range are mainly designed

More information

series KFD-KLD Linear slot diffusers

series KFD-KLD Linear slot diffusers series KFD-KLD Linear slot diffusers www.koolair.com KFD-KLD Contents Linear slot diffusers KFD Selection tables KFD Dimensions 6 Connection system Linear slot diffusers KLD 8 Selection tables KLD 0 Dimensions

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

Displacement flow diffusers. L e

Displacement flow diffusers. L e Displacement flow diffusers L-08-1-04e Contents Application Safety instructions Contents Application Safety instructions 2 Construction Perforation Principle of operation Example of quick selection 3 Type

More information

NH 3. Evaporator. Ammonia Applications Tons MANP

NH 3. Evaporator. Ammonia Applications Tons MANP NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With

More information

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 300 203 PERFORMANCE CURVE 500 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 The best and most cost-efficient solution for applications where small, flexible and easy-touse arms are required. Nederman FX2 arms are made of lightweight anodized aluminium sections, with three adjustable,

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics

Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics Application SMART-UL fans have been designed for general ventilation of buildings. They are meant for forwarding the dry air of maximum temperature 140 F, and dustiness not exceeding 0,3 g/m³, without

More information

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02 GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV vertical outlet Issue 07/02 Roof fans made of plastic materials Series VRV with vertical outlet Usable in ventilation engineering of all branches

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE PRODUCT SELECTION DATA Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers 09PE Translation of the original document N 20030, 02.2017 Use 09PE The 09PE range is particularly

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8

1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8 These technical specifications state a row of manufactured sizes and versions of whirling air outflow outlets VVDM 300, 400, 500, 600, 625 und 825 (further only outlets). It is valid for production, designing,

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller. VKS VKSA Features Power supply Temperature range 400x200 mm to 1000x500 mm flanges; Airflow up to 9200 m 3 /h; Can be mounted on floors, walls or ceilings; Forward-curved galvanized steel impeller; Cost-effective;

More information

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 Ceiling or wall mounting extract ventilation Extract ventilation through wall or using a shunt duct system All V models incorporate all accessories

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information Alsident System100 Aluminium (AL) Product Information System 100 Aluminium (AL) General Information Product Specification Product Description System 100 Aluminium Alsident System airflow between 140-400

More information

Art. No. Model Designation Remark. per unit Ducting 150 mm fire resistant Alu (1,2-5 meter extendable)

Art. No. Model Designation Remark. per unit Ducting 150 mm fire resistant Alu (1,2-5 meter extendable) Units 10-60020 S400 Mist Collector S 400 420m 3 /min 10-60021 Mist Collector S 400 Stainless Steel (7m 3 /min) 10-60120 S800 Mist Collector S 800 800m 3 /min 10-60121 Mist Collector S 800 Stainless Steel

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF

More information

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser 1/1.5/B/1 Plaster In Grilles AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44 (0) 1842

More information

VOLUME CONTROL / REGULATING DAMPERS

VOLUME CONTROL / REGULATING DAMPERS VOLUME CONTROL / REGULATING S PRODUCT RANGE Model Range Includes A - Multi-Leaf. (Flanged - Rectangular Duct) B - Multi-Leaf. (Slip joint / Spigot - Rectangular Duct) C - Multi-Leaf. (Slip joint / Spigot

More information

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight

More information

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 The best and most cost-efficient solution for extraction of hazardous airborne contaminants, in applications where small, flexible and easy-to-use arms are required. Nederman FX2 arms are made of lightweight

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

Fantronix Hydroponic Wholesale Price List. July 2014 Revision 1

Fantronix Hydroponic Wholesale Price List. July 2014 Revision 1 Fantronix Hydroponic Wholesale Price List July 2014 Revision 1 Terms & Conditions How to deal with us Firstly, you will need to register with us by visiting www.fantronix.com and click on the Trade Account

More information

Smoke damper EKO-SRB1

Smoke damper EKO-SRB1 Smoke damper EKO-SRB1 Description The EKO-SRB1 smoke damper is a CE-approved damper in fire class E60 intended for fire compartmentation or protection against the spread of fire and smoke in ventilation

More information

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,

More information

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS S ACON EQ NTS ACON E NTS A S EQ A TS TS TS TS TS E AC AC AC AC AC AC S S UIP IPME IPME QU P QUI QUI EQ EQUI Q EQ EQ EQ EQ EN EN SE SE SEAC AC AC AC AC AC AC ACO EQUIP E MEN SEACO EQUIPMEN A EQU EQU AC

More information