In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.
|
|
- Cuthbert Page
- 6 years ago
- Views:
Transcription
1 In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V 5 FC-HT FD 61 Domestic Fans ccessories Electric Diagrams General Information Index FH 63 FS FK ccessories
2 xial-flow Fan COMPCT cased version Construction Motor with painted cast aluminum casing. Impellers made of injection moulded plastic reinforced with anchored fiberglass, UV stable (TCFT/TCF), or die casted in aluminium (TCT/TC). Dynamic balanced according to ISO 194. djustable impellers in plastic or aluminium can be supplied on request. For duct installation the fan is mounted in a casing of steel sheet. The motor and the unique construction of the impeller give compact solidity and allow wall- and duct-mounting in all variable positions. Motor 3 415V, Hz three-phase alt. 4V, Hz single-phase asynchronous motor, thermal protection with outgoing leads to the TCFT, TCF terminal box. Enclosure IP according to UNE 113 and IEC 34 1 (size /4-7 and are IP55). Insulation class F for a maximum environmental temperature of +7 C. The motor is designed according to IEC 34 1 and is dynamic balanced according to ISO 194. Speed controllable by variation of the supply voltage by means of transformer or electric regulator (not size /4-5, -4-63, 7 and ). Special voltage or frequency, improved enclosure can be supplied on request. Wiring diagram, see page 35. Model numbering system Special version Ex L S = air direction motor - impeller for wall mounting = air direction impeller - motor, standard for duct mounting = explosion proof motor EExe II T3 = weather proof enclosure M = extended lead (3mm long) = motor and impeller only lade angle H = high (approx 34 ) L = low (approx ) Nominal diameter in mm Speed: = approx rpm Hz 4 = approx 1rpm Hz 6 = approx rpm Hz = approx rpm Hz of motor: T = three-phase = single-phase Impeller: F = fixed blades impeller, standard G= adjustable blade impellers = impeller in aluminium C = compact series Fan mounting: H= wall mounted T = case duct mounted ccessories COP page 6 RE page 3 RM, RMT page
3 (6/ p) C D E N 4 16 Ø Ø Ø 7/L 7/H /L /K /G /H C D 7 7 4p E 6p p (4 p) (4 p) Ø Ø -/H -315/G -355/J 4-/H 4-315/H 4-355/H 4-/H 4-/H 4-/H 4-5/L 4-5/H 4-63/L 4-63/H 4-7/L 4-7/H 4-/L 4-/K 4-/G 4-/H Hz Hz 6-355/H 6-/H 6-/H 6-/H 6-5/L 6-5/H 6-63/L 6-63/H 6-7/L 6-7/H 6-/L 6-/K 6-/G 6-/H -/H -/H -5/H -63/H -7/H -/L -/K -/G -/H Hz Hz Number of holes Dimensions in mm POLE 4 POLE 6 POLE POLE xial-flow Fan COMPCT cased version coustic characteristics Sound pressure level d()
4 xial-flow Fan COMPCT cased version Technical specification TCFT / TCF Number of poles Cased version Speed rpm Maximum power W Maximum current 3 V V Sound pressure level d () Duty at free discharge (max) m³/h Weight kg Speed regulation device rticle number TCF/-/H 1, TCF/4-/H 133, RE TCF/4-315/H 1, RE TCF/4-355/H 5 1, 5 34 RE-, TCF/4-/H TCF/4-/H ,6, RE-,5 RE-, TCF/4-/H 6 3, RE-5N SINGLE-PHSE 6 TCF/4-5/H TCF/4-63/H TCF/6-355/H TCF/6-/H TCF/6-/H TCF/6-/H TCF/6-5/H ,9 7,6,5,6 1, 1,6, RE-5N RE-1 RE-1 RE-,5 RE-,5 RE-, TCF/6-63/H 5,6 7 5 RE-5N TCF/-/H 13, RE TCF/-/H TCF/-5/H ,9 1, RE-1 RE-, TCF/-63/H , RE-, TCFT/-/H,9, TCFT/4-/H 133,3, TCFT/4-315/H 1 1,6, TCFT/4-355/H,, TCFT/4-/H TCFT/4-/H ,4 1,7, 1, TCFT/4-/H 13 6,7 1, RMT-3, THREE-PHSE 6 TCFT/4-5/H TCFT/4-63/H TCFT/6-355/H TCFT/6-/H TCFT/6-/H TCFT/6-/H ,9 5,,5,5,,9,3 3,,3,3,5, RMT-3, TCFT/6-5/H 4 1,6, TCFT/6-63/H 4, 1, TCFT/-/H 6 13,7, TCFT/-/H TCFT/-5/H 6 1 3,7 1,,4, TCFT/-63/H ,3,
5 xial-flow Fan COMPCT cased version Technical specification TCT / TC Number of poles TC/-/H Speed rpm Maximum power W 4 Maximum current 3 V V 1, Sound pressure level d () Duty at free discharge (max) m³/h Weight kg, Speed regulation device rticle number SINGLE-PHSE 4 6 TC/4-/H TC/4-315/H TC/4-355/H TC/4-/H TC/4-/H TC/4-/H TC/4-5/L TC/4-5/H TC/4-63/L TC/6-355/H TC/6-/H TC/6-/H TC/6-/H TC/6-5/L TC/6-5/H TC/6-63/L TC/6-63/H TC/6-7/L TC/6-7/H ,3,6 1, 1,6,7 3,5 5, 7,7,4,5,6 1, 1,7,4, 3,1 5,4 5,5 6, , 11, 13, 15,5 1, 5, 33, 34,7 4, 13, 15,5,7 4, 33, 33,5 3, 3,5 46, 46, RE-1 RE-1 RE-,5 RE-,5 RE-5 RE-5 RM- RE-1 RE-1 RE-,5 RE-,5 RE-5 RE-5 RE-5 RM TC/-/H TC/-/H TC/-5/H TC/-63/H TC/-7/H TCT/-/H , 1, 1,4,1,4,9, ,7 4, 33, 3,5 46,, RE-1 RE-,5 RE-,5 RE-, THREE-PHSE 4 6 TCT/4-/H TCT/4-315/H TCT/4-355/H TCT/4-/H TCT/4-/H TCT/4-/H TCT/4-5/L TCT/4-5/H TCT/4-63/L TCT/4-63/H TCT/4-7/L TCT/4-7/H TCT/4-/L TCT/4-/K TCT/4-/G TCT/4-/H TCT/6-355/H TCT/6-/H TCT/6-/H TCT/6-/H TCT/6-5/L TCT/6-5/H TCT/6-63/L TCT/6-63/H TCT/6-7/L TCT/6-7/H TCT/6-/L TCT/6-/K TCT/6-/G TCT/6-/H ,3,6, 1,4,7,9 3,9 4,9 5,6 7,1,4 11,1 11, - - -,5,5,9 1, 1,6 1,7, 4,9 5,7 5, 5,7 7,1 9,,7,,3,5, 1,6 1,7,3, 3, 4, 4, 6,4 6,5 9, 11,6 15,,3,3,5,6,9 1, 1,3, 3,3 3, 3,3 4,1 5, 6, , 11, 13, 15,5 1, 5, 33, 34,7 39, 4, 46, 54,, 6, 1, 9, 13, 15,5,7 4, 33, 33,5 3, 3,5 46, 46,, 64, 6,, RMT-3,5 RMT-3,5 RMT- RMT-3,5 RMT-3,5 RMT-3,5 RMT TCT/-/H TCT/-/H TCT/-5/H TCT/-63/H TCT/-7/H TCT/-/L TCT/-/K TCT/-/G TCT/-/H , 1, 1, 1,9,1 3,1 4,3 4, 6,,5,6,7 1,1 1, 1,,5, 3, ,7 4, 33, 3,5 46, 54,, 61, 64, RMT-3,
6 xial-flow Fan COMPCT cased version Performance curves
7 xial-flow Fan COMPCT cased version Performance curves
8 xial-flow Fan COMPCT cased version Performance curves
9 xial-flow Fan COMPCT cased version Performance curves
10 xial-flow Fan TCx, TCTx Construction xial fan in cased version with casing of welded steel sheet and two contrarotating impellers made in die casted aluminium, dynamically balanced according to ISO194. TCx, TCTx Data TCx/4- TCx/4- TCx/4-5 TCx/4-63 Speed rpm Maximum power absorbed kw 1,4 1,7 3,5 3, Motor Two 3-415V, Hz three-phase alt. two -4V, Hz singlephase asynchronous motor, therminal protection with outgoing leads to the thermal box. Enclosure IP, insulation class F. Size and are speed controlled by means of transformer or electric regulator. Special voltage or frequency, improved enclosure and three-phase motors for Y resp. running can be supplied on request. Wiring diagram, see page 35. Maximum current 5,4 7,3 15, 19, Sound level* d () 7 Maximum duty m³/h Weight kg 4 rticle number TCTx/4- TCTx/4- TCTx/4-5 TCTx/4-63 * - inlet ,5 1, 3, 4, 3,4 3, 5,, coustic characteristic Sound pressure level d() inlet outlet inlet outlet 5 inlet 5 outlet 63 inlet 63 outlet ccessories Working point m³/h Total COP page 6 RM, RMT page
11 xial-flow Fan TCx, TCTx Performance curves Pe Pa mmh O Dimensions in mm Ø ØC ØD ØE No. of holes N
12 xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof steel or galvanized steel and impellers in fiberglass reinforced polyamide, in die-cast aluminium or steel sheet may be supplied on request. Motor -4/3-4V, Hz (3-4/6-6V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC34-1. Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram, see page 35. FC MOILE REV Model numbering system F C / - 4-1T T - Three phase Power rate 1.5 kw x = 1 Diameter of the fan in mm 4 6 C - ~ rpm - ~ 1 rpm - ~ 19 rpm - Cased version F - xial fan ccessories Sleeve FC page FC page Sleeve coupling FC page Protection net FC page PER-CN page
13 xial-flow Fan FC Technical specification Speed rpm Voltage V Motor power kw Maximum current Sound level* d () Maximum duty m³/h Weight kg rticle number FC/--5S FC/ S FC/ S FC/--5T FC/--37T FC/ T FC/-315-T FC/ T FC/-355-1T FC/--1 FC/-- FC/-- FC/-- FC/4-5-1 FC/4-63- FC/4-7- FC/4-- FC/4-- FC/4-P-7 FC/4--1 FC/6--1 FC/6-1-1 FC/--1 * - distance 1 m Dimensions in mm V 3V 3V V V V V V V V V V V V V V V V V V V V V,5,37,55,5,37,37,,55 1,1 1,5, 3, 3, 1,5, 4, 4, 4, 7,5 11, 11, 11, 11, 1,,5 3,4, 1, 1, 1,9 1,35,5 3,4 4,7 6,5 6,5 4,3 4,,1,1,1 14,4 1,,, 5, FC/--37 FC/ FC/ FC/--1 FC/-- FC/-- FC/4-5-1 FC/4-63- FC/4-7- FC/4-- FC/4-- FC/4-P-7 FC/4--1 FC/6--1 FC/6-1-1 FC/--1 C D E Number of holes D C ir direction E ssembly instructions fan protection net sleeve coupling mounting flange sleeve duct
14 xial-flow Fan FC Performance curves FC/--5 FC/--37 FC/ FC/ Pa 1 Pa 1 m³/h m³/h FC/ FC/ FC/--1 FC/-45- FC/-- FC/-- Pa Pa m³/h 7 m³/h FC/4-5-1 FC/4-63- FC/4-7- FC/4-- Pa 3 1 Pa m³/h 3 m³/h
15 xial-flow Fan FC FC/4-- FC/4-P-7 FC/4--1 FC/6--1 Pa Pa 3 4 m³/h m³/h FC/6-1-1 FC/--1 Pa m³/h
16 xial-flow Fan FC - V Construction elt driven axial-flow fan for installation in a ducted system. Casing of powder coated steel sheet, RL5. Impellers in fiberglass reinforced polyamide. Casing in acid-proof steel or galvanized steel and impellers in die-cast aluminium or steel sheet may be supplied on request. Maximum allowed temperature for transported air is - C to C. For performance curves see FC. Motor -4/3-4V, Hz (3-4/6-6V over 3kW) three phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram see page 35. Model numbering system FC-V/4-7- T Three phase motor Power rate x=4kw Fan diameter in mm Motor poles Fan series FC - belt driven ccessories Sleeve FC Stand FC Coupling Protection net page page page page
17 xial-flow Fan FC - V Data and dimensions in mm H L For characteristics see FC. Data Voltage Motor Maximum power current L H rticle number V kw FC-V/--1 1,5 3, FC-V/-- 3 6, FC-V/-- 3 6, FC-V/ ,5 4, FC-V/4-63-, 4, FC-V/4-7- 4, FC-V/4-- 4, FC-V/4-- 4, FC-V/4--7 7,5 14, FC-V/ ,
18 xial-flow Fan FC - HT Construction xial fan designed for installation in a ducted system. Casing of steel sheet, powder coated RL74. Made for temperatures up to C continuous running ( C min/h). Impeller in die-cast aluminium. Casing in acid-proof steel or galvanized steel may be supplied on request. For performance curves see FC. Motor -4/3-4V, Hz (3-4/6-6V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor. Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, may be supplied on request. Wiring diagram see page 35. Model numbering system FC-HT/4-7- T Three phase Power rate x=4kw Fan diameter in mm Motor poles Fan series FC - high temperature ccessories Sleeve FC Stand FC Coupling Protection net page page page page
19 xial-flow Fan FD Construction xial-flow fan in cased version with casing welded of acid-proof steel and reversible impeller in die casted aluminium, dynamically balanced according to ISO194. The fan is suitable for usage in environments with very high humidity. Motor -4/3-4V, Hz (3-4/6-V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC34-1. Insulation class H, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram, see page 35. C Model numbering system F D / T T Three phase Power rate.9 kw x = Diameter of the fan in mm Motor poles D F Reversible version xial fan Data Speed rpm Motor power kw Voltage V Maximum current Maximum duty m/h ³ rticle number FD/4--5T FD/4--37T FD/4--55T FD/4-5-T FD/4--T FD/4--T FD/4--T ,5,37,55,,, 3,,,9 1,5,4,4 4, 6,5 4, 6,, 11, 13, 17, 6, Dimensions in mm D E 4 xø
20 xial-flow Fan FD Performance curves Pa m/h Pa 1 3 m/h
21 xial-flow Fan FH Construction ifurcated axial fan in tubular version, with motor placed in a chamber, isolated from the air stream. Design allows continuous transportation of gases with max. temp. 1 C. Casing of rolled and electro-welded steel sheet, powder coated. Impeller in die-casted aluminium. Casings in acid-proof steel or galvanized steel and impellers in steel sheet may be supplied on request. Motor -4/3-4V, Hz (3-4/6-V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram, see page 35. Model numbering system F H / - 4-1T Maximum allowed temperature +1 C - continuos running T - Three phase Power rate 1,1 kw x = 1 + C - temporary running Diameter of fan in mm Motor poles H - High temperature version F- xial fan Dimensions in mm C E F H No. of holes FH FH FH FH FH FH FH Technical specification FH/--1 S FH/--1 T FH/4--37 T FH/-- T FH/4-- T FH/ T FH/4-7- T FH/ T FH/6--1 T FH/6--1 T * - distance 3 m Speed rpm Motor power kw 1, 1,,37 3,, 1, 4,,55 1, 1, Maximum current ( V),, 1,7 6, 1,1,7,3 1,,, Maximum duty m³/h Sound level * d () rticle number
22 xial-flow Fan FH Performance curves P st Pa FH/--1 FH/4--37 FH/-- P st Pa 3 FH/ FH/4-- 4 P st Pa m/h FH/4-7- FH/ Q 1 P st Pa FH/6--1 FH/ Q 3 m/h 6-7 Q Q 3 m/h 3 m/h
23 xial-flow Fan FS Construction xial-flow fan with vertical stand, casing in welded steel sheet, fan blades in fiberglass reinforced polypropylene with a hub in aluminium, dynamically balanced according to ISO194, wire guards on the inlet and outlet. The fan is provided with a protection nets and a pre-assembled switch with a speed regulator. The fan can be used as a local cooler, dryer, exhauster or temperature balancer. Motor -4V, Hz single-phase asynchronous motor. Enclosure IP55, class F insulation. Special voltage or frequency, and enclosure may be supplied on request. Wiring diagram, see page 35. Dimensions in mm D L H FS/-3-55S 3 5 FS/--1S 4 4 FS/4-5-1S 4 Data Speed rpm Motor power kw Maximum current Voltage V Maximum Sound Weight pressure flow level m ³ /h d () kg rticle number FS/-3-55S,55 3, FS/--1S 1, 7, FS/4-5-1S 1, 7,
24 xial-flow Fan FS Performance curves Pa m ³ /h
25 xial-flow Fan FK Construction xial-flow fan for duct mounting with a casing in welded steel sheet, fan blades in fiberglass reinforced polypropylene with a hub in aluminium, dynamically balanced according to ISO194, wire guards on the inlet and outlet. The fan is provided with a stand and a pre-assembled switch with a speed regulator. The fan can be used as a local cooler, dryer, exhauster or temperature balancer. Motor 4V, Hz single-phase asynchronous motor according to UNE-113 and IEC34-1, with a thermal motor protection type Klixon. Enclosure IP55, class F insulation. Special voltage or frequency, and enclosure may be supplied on request. Wiring diagram, see page 35. Data Speed rpm Voltage V Motor power kw Maximum current Maximum duty m³/s Sound level* d () rticle number FK , 1,, FK ,1 1, FK- 14 3,37, 1, FK- 14 3,55 3, FK- 14 3,55 3,, FK ,55 3, * - distance 1 m Dimensions in mm F D E F FK D FK FK- 5 3 FK- 6 E FK- FK
26 ccessories PER-W Louvre shutters in plastic PER- W PER-5 W PER-1 W PER- W/N PER- W/N PER- W/N PER-3 W/N PER- W/N PER- W/N PER- W/N C ØD ØE D C PER-5 W/N PER-6 W/N D PER-7 W/N PER- W C PER- W PER-CN Louvre shutters in aluminium sheet PER- CN PER-355 CN PER- CN PER- CN PER- CN PER-63 CN PER-7 CN PER- CN PER- CN C COP Flexible flange connector COP- COP-315 COP-355 COP- COP- COP- COP-5 COP-63 COP-7 COP- Ø Max Min ØC ØD ØE N -Noof holes
27 ccessories Mounting base FC D holes ØE C D E Sleeve FC max min C D E N - No Sleeve coupling FC Protection net FC of holes C D E N - Number of holes Protection nets for inlets and outlets for axial fan FC may be delivered on request
Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof
More informationsupplied in Form (B) configuration. Airflow over Impeller- Motor.
CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,
More informationROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series
asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air
More informationShort casing. Long casing (L version) Commercial premises
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled
More informationHXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance
PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel
More informationCONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7
CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound
More informationCOMPACT Series type HCFB / HCFT (Plastic impellers)
Plate mounted axial flow fans COMPACT HCFB/HCFT PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCFB / HCFT (Plastic impellers) 0 017582 603079 Compact design Corrosion resistance Flame retardant terminal
More informationSabre Plate Mounted Sickle Fans (VSP)
Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationAxial fans. What s more, non-stock models are normally available within two weeks.
Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive
More informationCGT Series Adjustable Pitch Fans
AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel
More informationIN-LINE DUCT FANS MIXVENT-TD Fan Systems
IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment
More informationPLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance
A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with
More informationPlate mounted axial flow fans HXBR / HXTR Series
Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester
More informationAXIAL FLOW CABINET FAN CGT Series
Range of adjustable pitch aerofoil blade, axial flow cabinet fans. Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25 mm thickness fireproof fibreglass acoustic insulation
More informationMixed Flow Roof Fans (RMH)
Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard
More informationPerformance. Sound Levels. Impellers. Motors. Accessories
EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class
More informationCONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,
RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from
More informationCENTRIFUGAL DIRECT DRIVE FANS CMT-CMB
CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The
More informationSpecifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).
Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and
More informationBACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series
Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the
More informationAC Commercial Fans Edition. ErP ready
AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application
More informationCYLINDRICAL CASED AXIAL FLOW FANS
- Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL
More informationCYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS
- ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate
More informationTSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.
TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys
More informationVKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.
VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.
More informationIN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems
IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range
More informationMixed Flow Roof Fans (RMH)
Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard
More informationBELT DRIVEN CABINET FANS CVTT Series
Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal
More informationDuct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ
Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3
More informationROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling
MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength
More informationCONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series
Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester
More information400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity
400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,
More informationGigaBox centrifugal fans Product specific information
GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,
More informationDuct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code
Tubes and ox Fans Duct Fans - ESTOC EC Range Features Sizes from 55 to 6 mm diameter ir flow 19, m /h (4. m /s) Static pressures up to 84 Pa Maximum temperature up to 6 C Controllable external rotor motors
More informationSeries VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h
SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.
More informationCSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller
CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys
More informationVKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.
Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,
More informationDevice can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.
VSV VSVI Features Power supply Temperature range Sizes Construction Installation Speed control options 9 sizes; Airflow up to 5300 m 3 /h; Vertical exhaust; Backward-curved plastic or galvanized steel
More informationACOUSTIC CABINET FANS CVAB / CVAT Series
Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models
More informationCMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C
BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured
More informationTGT Series Adjustable Pitch Fans
CYLINDRICAL CASED AXIAL FLOW FANS Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot dipped
More informationCMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced
CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC
More informationCVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.
ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic
More informationTGT Series Adjustable Pitch Fans
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationMax. airflow m 3 /s Diam. min. Diam. max
Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89
More informationIN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series
Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to
More informationDevice can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.
VSA 3. ROOF FAS Features Power supply Temperature range 4 sizes; Airflow up to 117 m 3 /h; Horizontal exhaust; Backward-curved impeller; ost-effective. 23V/5Hz/1f. From -4 up to 4/65. Sizes 19 S, 19, 22
More informationAXIAL FANS Catalogue CN0050C01 May 2008
ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced
More informationAAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:
AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average
More informationMegaBox Product-specific information
MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions
More informationCategory 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence
Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion
More informationVent-Axia Sabre Sickle Roof Fans (VSR)
Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,
More informationSquare Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.
Square Duct Fans - ESTOC TARGE Range Features Sizes from 55 to 6 mm diameter Air flow 21, m /h (5.8 m /s) Static pressures up to 145 Pa Maximum temperature up to 11 C Controllable external rotor motors
More informationTD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans
IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester
More informationCRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS
ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire
More informationSingle-inlet centrifugal fans
CE 200-280 4-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CE fans are easy to install. Fans in this series have impellers with forward-curved
More informationSabre Sickle Fan Assisted Roof Cowls (VSR)
Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught
More information3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page - SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 PERFORMANCE CURVE 32-125 5 PERFORMANCE CURVE 32-6 PERFORMANCE CURVE 32-0 7 PERFORMANCE CURVE 40-125 8 PERFORMANCE
More informationCompany name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017
Position Qty. Description 1 CM5-4 S-R-I-E-AQQE Product No.: 98482185 Compact, reliable, horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The pump
More information3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE CURVE 320 8 PERFORMANCE
More informationCAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power
CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators
More informationTerminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.
EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)
More informationCM5-5 A-R-A-E-AVBE F-A-A-N
GRUNDFOS DATA BOOKLET CM5-5 A-R-A-E-AVBE F-A-A-N Grundfos Pump 9686818 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/9686818/cm5-5-a-r-a-e-avbe.html
More informationCM10-3 A-R-A-E-AVBE F-A-A-N
GRUNDFOS DATA BOOKLET CM1-3 A-R-A-E-AVBE F-A-A-N Grundfos Pump 9686946 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/9686946/cm1-3-a-r-a-e-avbe.html
More informationSize and Configurations
!!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent
More informationCBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.
LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation
More informationDynamically-balanced impellers with extremely robust cores CMP T 5.5
Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.
More informationData sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m
Data sheet Item no.: 2600 Page: 1 / 5 Operating data Requested flow rate 40.00 m ³/h Actual flow rate 40.00 m ³/h Requested developed head 68.00 m Actual developed head 68.00 m Pumped medium Water Efficiency
More informationData sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design
Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature
More informationThermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection
General Systemair thermo fans have been developed for the use in exhaust air systems where media with increased temperatures have to be transported. The special design allows a reliable operation also
More informationBifurcated Case Axial Fans (BIFA)
Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient
More informationfranklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps
franklinwater.com 5 Hz VR SERIES Vertical Multi-Stage Pumps 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features 2 Applications 2 Pump Specifications Counter-Flange Kits Motor Specifications 4 Ordering
More informationShort casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles
CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Additional Information Standard air direction: form (B) configuration (Impeller over ). models description: incorporated an "L" after blade pitch angle. E.g.
More informationData sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.
Data sheet Item no.: 1900 Page: 1 / 5 Operating data Pumped medium Water Actual flow rate 72.19 m ³/h Operating data determined for maximum inlet pressure Actual developed head 70.26 m Clean water Efficiency
More informationMedium Pressure Centrifugal Fans
Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock
More informationTHT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G
THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.
More informationMAJAX-2 GENERAL SPECIFICATION
MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed
More informationTube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.
Tube Fans - ROPERA Range Features 1 mm to 355 mm diameter Air flow 234 m 3 /h (.65 m 3 /s) Static pressures up to 92 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection
More informationEnergy-saving motors (ESM)
Energy-saving motors (ESM) Technology Accessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans A series fans Energy-saving motors (ESM) 316 Air performance curves 3 Energy-saving
More information- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 204 GAMMA 205 CURVE SPECIFICATIONS 206 PERFORMANCE CURVE 1X 207 PERFORMANCE CURVE 2X 208 PERFORMANCE CURVE 3X 53.7 209 PERFORMANCE CURVE
More informationTransformer Oil Cooling Solutions
pumps and fans Transformer Oil Cooling Solutions Series NTG/ TG/ TGCL Pumps TF/ TFBR/ NTF/ VTTF Fans quality certificate INDEX The company Portfolio Development PUMPS Nomenclature Inline axial pumps NTG
More informationUnobox units with backward curved centrifugal impellers
Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase
More informationExplanation of AR Series Ventilator Products. Fan type code D S AR AE
Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction
More informationCHMT Series, F Rated Fans
CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke
More informationSmall centrifugal fans made of plastic
Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18
More informationIN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series
Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).
More informationROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE
ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4
More informationCVHT Series - F rated cabinet fans
N 50-55 1/1/08 19:26 Página 50 BLT DRIVN BINT NS Series - 00 120 rated cabinet fans NW pproved to N12101- standard Range of belt drive cabinet fans designed for smoke extraction in fire conditions and
More informationCentrifugal medium-pressure fans fitted with multi-blade
CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in
More informationROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling
ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for
More informationErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR
13 POWERBOX EC FANS - ESTOC EC FEATURES Sizes from 3 to 3 mm diameter Air flow up to.1 m 3 /s Static pressures up to Pa Controllable EC motors Multiple outlet orientations ELECTRICAL SUPPLY 22-2V/Hz/1f
More informationCM5-11 A-R-G-E-AQQE F-A-A-N
GRUNDFOS DATA BOOKLET CM5-11 A-R-G-E-AQQE F-A-A-N Grundfos Pump 96935476 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/96935476/cm5-11-a-r-g-e-aqqe.html
More informationCM1-6 A-R-I-E-AQQE F-A-A-N
GRUNDFOS DATA BOOKLET CM1-6 A-R-I-E-AQQE F-A-A-N Grundfos Pump 97515122 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/97515122/cm1-6-a-r-i-e-aqqe.html
More information3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page
CONTENTS Page SPECIFICATIONS 0 PERFORMANCE RANGE and SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE
More informationCM25-1 A-R-G-E-AQQE C-A-A-N
GRUNDFOS DATA BOOKLET CM25-1 A-R-G-E-AQQE C-A-A-N Grundfos Pump 97516666 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/97516666/cm25-1-a-r-g-e-aqqe.html
More informationHigh efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable
KD High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable Electrical accessories S-ET p. 341 The KD series have external rotor
More information