Packing Pumps Empty Column Hardware Guard Columns Frits High Pressure Fittings, Connectors, and Adaptors

Size: px
Start display at page:

Download "Packing Pumps Empty Column Hardware Guard Columns Frits High Pressure Fittings, Connectors, and Adaptors"

Transcription

1 LC CAccessories Section Packing Pumps Empty Column Hardware Guard Columns Frits High Pressure Fittings, Connectors, and Adaptors Alltech , SSI Valco Rheodyne Fittings and Accessories Low Pressure Fittings, Connectors, Adaptors, and Accessories Alltech Tubing Stainless Steel PEEK and Flex-Connect Teflon and Tefzel NO-OX Tubing Cutters and Accessories Mobile Phase Handling Products Column Prefilters Inlet Filters and Funnel Systems , Reservoirs/Caps Degassing Recyclers Pressure Regulators/Mixers , 511 Pump Parts Check Valves Seals and Pistons Accessories Valves and Accessories Column Selectors Valve Systems Rheodyne Valves Rheodyne Replacement Parts and Accessories Sample Loops ASI Flow Splitting Valves Hamilton Low Pressure Valves Rheodyne Low Pressure Valves SSI High Pressure Valves Organizers and Test Mixtures

2 Column Packing Accessories Pumps Standard Slurry Packer High-Capacity Slurry Packer 5375 This self-contained solvent/slurry delivery module is designed for use in any laboratory with the need to produce its own HPLC columns. The unit is very compact and can be operated in virtually any location that has a source of compressed air (50 to 125psig, 3-4CFM). Powered by an air amplification pump, the unit is capable of packing columns of both analytical and semi-preparative scale (2.1mm to 10mm ID). An air regulator located on the face of the unit provides an easy control of the packing pressure. All operating pressures are clearly displayed on two large gauges to ensure safe and effective column production. A two-way slider valve is incorporated into the solvent delivery system, which allows either of two pressurizing solvents or a wash solvent to be used without shutting down the system. Detailed directions make it possible to produce quality HPLC columns with minimal practice. Each Alltech Slurry Packer comes with a 20mL slurry reservoir and a 4.6mm ID pre-column assembly. Individual reservoir assembly components and complete reservoir kits of other volumes and sizes are available to enhance the versatility of the packing unit. Standard Slurry Packer Specifications Pressure Rating: 10,000psig (max.) Amplification Ratio: 110:1 (drive area to liquid plunger area) Air Line Requirements: psig at 3-4CFM Air Inlet: 1/4" Tube Fitting Liquid Outlet: 1/16" SSI Fitting 5406 This specially designed high-pressure pump is recommended for packing HPLC columns from 4.6mm to 1" ID. The unit is safe to operate and, with the addition of a toggle valve to the air supply, may be activated from a remote location. The pump is a single-action, reciprocating-plunger pump. The drive is a pilot-controlled, continuously-cycling, double-acting, air cylinder. This particular pump model has a practical work ratio of 122:1 (drive area to liquid plunger area - e.g. when driven with an inlet air pressure of 100psig, the pump would produce 12,200psig hydraulic pressure). The apparatus is intended for permanent installation, requiring that it be bolted or otherwise fixed to a benchtop. Solvent pressure gauge, slurry reservoir, and empty columns are not included. High Capacity Slurry Packer Specifications Pressure Rating: 15,000psig (max.) Amplification Ratio: 122:1 (drive area to liquid plunger area) Air Line Requirements:50-150psig at 4-5CFM Liquid Displacement: 11cc/Stroke Air Inlet: 1/4" Tube Fitting Liquid Outlet: 1/4" Tube Fitting Alltech Slurry Packing Pumps Slurry Packers Standard Slurry Packer 1666 (Includes 20mL Reservoir Kit) High-Capacity Slurry Packer (Reservoir Kit & Solvent Pressure Gauge Sold Separately) Reservoir Kits and Replacement Parts Slurry Reservoir Kits 5491 Solvent Pressure Gauge Slurry Reservoirs Kits 1/4" Outlet, 20mL /4" Outlet, 40mL /4" Outlet, 80mL /8" Outlet, 20mL /8" Outlet, 40mL /2" Outlet, 20mL /2" Outlet, 40mL ;; ;; Nut Inlet Cap Housing Outlet Cap Nut Pre-Column 0916 Replacement Reservoir Housings 20mL Body mL Body mL Body Replacement Inlet Cap 1/16" SSI Inlet Cap

3 Column Packing Accessories Empty Hardware Stainless Steel Analytical Columns Reliable and Easy to Use 4.6-, 4.1-, 3.9-, 3.2- and 2.1-mm Internal Diameters Type 316 Stainless Steel Construction Endfitting Ferrule Frit/Insert Stop Depth (0.100") Compression Screw Insert Frit Figure Threaded Column Tube Endfitting Alltech s empty stainless steel analytical columns come complete with the threaded tube, 2 industry standard frit inserts, and 2 stainless steel endfitting nuts. The industry standard frit/insert means it will contain a stop depth equal to 0.100" (see Figure 1). A stainless steel frit is pressed into the PEEK insert piece with the resulting assembly providing strength and improved sealing. A 2.0µm frit is standard, but 0.5µm porosities are available. Adaptors and sealing rings are available for slurry packing your own columns (see Figure 2). The packing adaptor comes with a 1/4" precolumn tube which connects directly to the 1/4" slurry reservoirs on page Stainless Steel Analytical Column Sealing Ring Packing Adaptor 2730 Figure 2 - Cut-away view of the packing adaptor, sealing ring, and stainless steel analytical column tube Stainless Steel Analytical Column Hardware Material: 316 SS Max. Temperature: 100 C Max. Pressure: 10,000psig Thread Type: UNF (CPI Standard Ports) Typical Use: Analytical HPLC Columns Stainless Steel Analytical Hardware 4.6MM ID 4.1MM ID 3.9MM ID 3.2MM ID 2.1MM ID PART NO. PRICE PART NO. PRICE PART NO. PRICE PART NO. PRICE Complete Columns 50mm mm mm mm mm Replacement Parts and Accessories for Stainless Steel Analytical Columns 4.6MM ID 4.1MM ID 3.9MM ID 3.2MM ID 2.1MM ID DESCRIPTION QTY PART NO. PART NO. PART NO. PART NO. PART NO. PRICE Endfittings Stainless Steel Ea Female (Type B ) Frit/Insert 2.0µm Porosity µm Porosity Packing Accessories Adaptor Ea Sealing Rings

4 Column Packing Accessories Empty Hardware Metal-Free PEEK-Lined 2.1 and 4.6mm ID Columns The Inertness of PEEK with the Strength of Stainless Steel Stainless Steel Outer Tube Allows Continuous Use to 8,000psig Available in 30 to 300mm Lengths Alltech s PEEK-Lined metal-free columns introduce a new level of mechanical strength to PEEK column hardware. By using a stainless steel outer wall with a PEEK liner, these columns have higher pressure ratings than standard PEEK hardware, but still provide a completely inert flow path. The column hardware consists of the column tube, two PEEK endfittings and two frit/inserts to retain the packed bed (see Figure 1). The endfittings feature standard CPI female ports, allowing easy plumbing with 1/16" OD tubing and standard fittings. PAT (PEEK alloyed with TFE) frits in the frit/insert assemblies are a unique porous material which combines inertness and durability. Adaptors and sealing rings are available for slurry packing your own columns. The packing adaptor comes with a 1/4" precolumn tube which connects directly to the 1/4" slurry reservoir kit on page 453. Metal-Free MF-Plus 7.5mm ID Columns Completely Biocompatible and Chemically Inert Rated for Continuous Use to 5,000psig Available in 50 to 300mm Lengths Alltech s MF-Plus metal-free column hardware has the mechanical strength, biocompatibility, and chemical resistance that ion chromatography and biotechnology applications demand. The basic column design is shown in Figure 2. The column itself consists of a threaded PEEK tube and two PEEK endfittings with the packed bed held in place by two PAT (PEEK Alloyed with TFE) frits. The endfittings accept 1/16" OD tubing via industry standard fittings. A distribution cone in the endfittings improves peak shape by optimal placement of the sample across the entire crosssection of the packed bed. Adaptors and sealing rings are available for slurry packing your own columns. The packing adaptor comes with a 3/8" precolumn tube which connects directly to the 3/8" slurry reservoir kit on page µm PAT Frit/Insert PEEK Frit Retaining Ring PEEK Endfitting PEEK-Lined Stainless Steel Column Tube PEEK Endfitting PEEK Column Tube (7.5mm ID) 2µm PAT Frit Figure 1 Metal-Free PEEK-Lined Column 5545 Figure 2 Metal-Free MF-Plus Column 5546 PEEK-Lined Column Hardware MF-Plus Column Hardware Material: PEEK, PAT Frits, SS Outer Tube Max. Temperature: 100 C Material: PEEK, PAT Frits Max. Temperature: 100 C Max. Pressure: Thread Type: Typical Use: 8,000psig Continuous use UNF (CPI Standard Ports) Ion Chromatography or Biological Separations Max. Pressure: Thread Type: Typical Use: 5,000psig Continuous use UNF (CPI Standard Ports) Ion Chromatography or Biological Separations PEEK-Lined 2.1 and 4.6mm ID Hardware and Accessories 4.6MM 2.1MM DESCRIPTION QTY PART NO. PART NO. PRICE Complete Columns 30mm Ea mm Ea mm Ea mm Ea mm Ea mm Ea Replacement Parts Endfitting Ea Frit/Insert Packing Accessories Packing Adaptor Ea Packing Seals MF-Plus 7.5mm ID Hardware and Accessories DESCRIPTION QTY PART NO. PRICE Complete Columns 50mm Ea mm Ea mm Ea mm Ea mm Ea Replacement Parts Endfitting Ea PAT Frit Frit Retainer Ring Packing Accessories Packing Adaptor Ea Packing Seals

5 Column Packing Accessories Empty Hardware Preparative Scale Column Hardware Threaded Format for Easy Assembly Column IDs of 7-, 10- and 22-mm Features Alltech s Patented Continuously Adjustable Piston (CAP ) Alltech s new easy-to-use Prep Scale format has simple threaded end cap holding adjustable pistons at each end of your column. The adjustable piston extends column life by compressing the packed bed to remove voids. Frit replacement is accomplished quickly and easily by putting in a new piston and securing with the end cap. Column Tube Piston/Frit Endfitting Analytical to Preparative Scale Hardware with Swaged Endfittings Passivated 316 Stainless Steel Construction Optimized Flow Geometry Uses Precision Bore Tubing and OptiFlow Endfittings Precision Bore Tubing for HPLC Columns Seamless type 316 stainless steel precision bore tubing is available with various OD's and ID's. This tubing meets the exacting inner surface area requirements for the fabrication of HPLC columns, and is intended for use with OptiFlow Endfittings. Alltech HPLC Column Tubing Material: 316 Stainless Steel Max. Temp.: 500 C Max. Pressure: 8500psig Typical Use: HPLC Column Assembly w/swageable Endfittings Replacement Piston/Frit Assembly Preparative Column Hardware Material: 316 Stainless Steel, PEEK Max. Temperature: 100 C Max. Pressure: 8,000psig Thread Type: UNF (CPI Standard ports) Typical Use: Prep HPLC Columns Preparative HPLC Column Hardware 5544 Precision Bore Tubing PER FOOT PER METER TUBING OD X ID PART NO. PRICE PART NO. PRICE Precision Bore Tubing 1/8" x 2.1mm /4" x 2.1mm /4" x 3.2mm /4" x 4.6mm /2" x 10 mm " x 22.5mm OptiFlow Swageable Endfittings DESCRIPTION ID LENGTH QTY PART NO. PRICE Complete Columns 7mm 100mm Ea mm 250mm Ea mm 500mm Ea mm 100mm Ea mm 250mm Ea mm 500mm Ea mm 70mm Ea mm 100mm Ea mm 250mm Ea mm 500mm Ea Replacement Endfittings 7mm Ea mm Ea mm Ea Replacement Piston/Frit Assemblies 7mm Ea mm Ea mm Ea Semi-Prep Packing Adaptors 7mm Ea mm Ea Alltech OptiFlow Endfittings feature a unique flow geometry which produces optimum distribution of sample and eluant across the surface of the column. A unique flow distributor located above the frit spreads the sample and eluant across the entire frit surface to improve peak symmetry and prevent frit blockage. OptiFlow Endfittings are precision machined from type 316 stainless steel, passivated with nitric acid and ultrasonically cleaned. Each fitting is supplied with a nut and ferrule for 1/16" tubing, a two micron stainless steel frit and distributor disk. 2µm SS Frit Distributor Disk Endfittings and Accessories Endfitting Tubing Nut and Ferrule DESCRIPTION QTY PART NO. PRICE OptiFlow Endfittings 1/4" Female Ea /8" Female Ea /2" Female Ea " Female Ea Semi-Prep Packing Seals 7mm mm Distributor Disks for 1/4" Column for 3/8" Column for 1/2" Column for 1" Column

6 Low Pressure Columns Empty Hardware Standard Omnifit Columns Borosilicate Heavy Wall Glass with Precision Threaded Ends and Patented Strain Free Endfittings Bore Diameter Constant to ± 0.1mm Higher Pressure Limits than Other Low Pressure Column Hardware O-ring Glass Column O-ring Each Standard Omnifit Chromatography Column includes two Teflon endpieces with a polypropylene outer cap, 25µm polyethylene frits, two support rods for mounting, two Omnifit flangeless tube endings, two gripper fittings, one coupling body and two meters of 1/16" Teflon tubing. Adjustable Plunger Teflon Frit Teflon Frit End Piece Omnifit Column Hardware Material: Borosilicate Glass, Teflon, Viton, Polypropylene, and Polyethylene Max. Temperature: 100 C Max. Pressure: Varies, see price block Thread Type: 1/4-28 UNF Typical Use: Low-pressure, Metal-free Columns Standard Omnifit Glass Column LENGTH PART NO. PRICE 6.6mm ID Column, rated to 60 Atm (900psig) 100mm mm mm mm mm mm ID Column, rated to 40 Atm (600psig) 100mm mm mm mm mm mm ID Column, rated to 20 Atm (300psig) 100mm mm mm mm mm mm ID Column, rated to 10 Atm (150psig) 150mm mm mm mm Standard Omnifit Glass Column Accessories DESCRIPTION QTY PART NO. PRICE 6.6mm ID Column Accessories Adjustable Plunger Ea µm Polyethylene Frits µm Teflon Frits µm Teflon Frits µm Teflon Frits Viton O-rings Silicone O-rings mm ID Column Accessories Adjustable Plunger Ea µm Polyethylene Frits µm Teflon Frits µm Teflon Frits µm Teflon Frits Viton O-rings Silicone O-rings mm ID Column Accessories Adjustable Plunger Ea µm Polyethylene Frits µm Teflon Frits µm Teflon Frits µm Teflon Frits Viton O-rings Silicone O-rings mm ID Column Accessories Adjustable Plunger Ea µm Polyethylene Frits µm Teflon Frits µm Teflon Frits µm Teflon Frits Viton O-rings Silicone O-rings

7 Column Accessories Frits Stainless Steel Frits Type 316 Stainless Steel Heat-Passivated 0.5µm and 2.0µm Porosities Stainless Steel Frits Material: 316 Stainless Steel Max. Temperature: 500 C Max. Pressure: 10,000psig Typical Use: Column Inlet/Outlet Dimensions Key for Stainless Steel and PAT Frits Frits DF = Frit Diameter PAT Frits Chemically Inert and Biocompatible Ideal for IC and Biochromatography Applications 2.0µm and 10µm Porosities PAT Frits Material: PAT (PEEK Alloyed with Teflon ) Max. Temperature: 100 C Max. Pressure: 10,000psig Typical Use: Column Inlet/Outlet PAT frits are made from PEEK and Teflon resulting in an inert, high-strength alloy. PAT frits exhibit improved chemical strength and lower protein binding than ultrahigh molecular weight polyethylene (UHMWPE) frits used by other manufacturers. T = Thickness 2105 Stainless Steel Frits FRIT DIAMETER (DF) THICKNESS (T) POROSITY PART NO. PRICE PART NO. PRICE 1/16" (1.57mm) 0.031" (0.79mm) 0.5µm " (0.79mm) 2.0µm /8" (3.175mm) 0.031" (0.79mm) 0.5µm " (0.79mm) 2.0µm " (1.59mm) 0.5µm " (1.59mm) 2.0µm /4" (6.350mm) 0.031" (0.79mm) 0.5µm " (0.79mm) 2.0µm " (1.59mm) 0.5µm " (1.59mm) 2.0µm /8" (9.525mm) 0.031" (0.79mm) 0.5µm " (0.79mm) 2.0µm " (1.59mm) 0.5µm " (1.59mm) 2.0µm /2" (12.7mm) 0.031" (0.79mm) 0.5µm " (0.79mm) 2.0µm " (1.59mm) 0.5µm /PKG 25/PKG 1" (25.4mm) 0.031" (0.79mm) 0.5µm " (0.79mm) 2.0µm " (1.59mm) 2.0µm PAT Frits 2 MICRON 10 MICRON FRIT DIAMETER (DF) THICKNESS (T) QTY PART NO. PRICE PART NO. PRICE 1/16" (1.57mm) 0.031" (0.79mm) 5/pkg " (1.59mm) 5/pkg /8" (3.175mm) 0.031" (0.79mm) 5/pkg " (1.59mm) 5/pkg /4" (6.350mm) 0.031" (0.79mm) 5/pkg " (1.59mm) 5/pkg /8" (9.525mm) 0.031" (0.79mm) 5/pkg " (1.59mm) 5/pkg /2" (12.7mm) 0.031" (0.79mm) 5/pkg " (1.59mm) 5/pkg

8 Column Accessories Frits Encased Stainless Steel and PAT Frits Better Peak Symmetry Better Sealing Better Mechanical Stability These frits are encased in rings of either PEEK, carbon-reinforced PEEK or stainless steel (SS). Because the carbon-reinforcement maintains its shape, it will not expand and stick in the end fitting like other plastic-encased frits. The diameter of the frit is matched to the inside diameter of the column, preventing sample and mobile phase from entering the space between the endfitting and the top of the column tube. As shown in the accompanying chromatograms, elimination of this stagnant flow pocket improves peak symmetry. Dimensions Key for Encased Frits Encased Frits DF = Frit Diameter DR = Ring Diameter T = Thickness DF T DR 2106 With Conventional Frit With Encased Frit Poor Resolution 5805 Increased Resolution Matching frit diameter to column ID improves resolution. Encased Frits 0.5 MICRON 2 MICRON 2 MICRON 2 MICRON 10 MICRON (5/PKG) (5/PKG) (10/PKG) (20/PKG) (5/PKG) FRIT DIAMETER (DF) RING DIAMETER (DR) THICKNESS (T) PART NO. PART NO. PART NO. PRICE PART NO. PRICE PART NO. PRICE SS Frits with PEEK Ring 0.083" (2.1mm) 0.250" (6.4mm) 0.063" (1.59mm) " (3.2mm) 0.250" (6.4mm) 0.063" (1.59mm) " (4.0mm) 0.250" (6.4mm) 0.031" (0.79mm) " (4.0mm) 0.250" (6.4mm) 0.063" (1.59mm) " (7mm) 0.375" (9.5mm) 0.063" (1.59mm) " (10mm) 0.500" (12.7mm) 0.063" (1.59mm) " (19mm) 1.000" (25.4mm) 0.063" (1.59mm) PAT Frits with PEEK Ring 0.063" (1.6mm) 0.250" (6.4mm) 0.063" (1.59mm) " (2.4mm) 0.250" (6.4mm) 0.063" (1.59mm) " (3.2mm) 0.250" (6.4mm) 0.063" (1.59mm) " (4.8mm) 0.250" (6.4mm) 0.063" (1.59mm) " (7.9mm) 0.375" (9.5mm) 0.063" (1.59mm) SS Frits with SS Ring 0.293" (7.5mm) 0.375" (9.5mm) 0.063" (1.59mm) " (10mm) 0.500" (12.7mm) 0.063" (1.59mm) " (22mm) 1.000" (25.4mm) 0.063" (1.59mm) SS Frits with Carbon-Reinforced PEEK Ring 0.083" (2.1mm) 0.250" (6.4mm) 0.031" (0.79mm) " (3.2mm) 0.250" (6.4mm) 0.031" (0.79mm) " (3.9mm) 0.250" (6.4mm) 0.031" (0.79mm) " (4.1mm) 0.250" (6.4mm) 0.031" (0.79mm) " (4.6mm) 0.250" (6.4mm) 0.031" (0.79mm)

9 Guard Columns All-Guard Cartridges All-Guard Cartridge System Elegantly Simple Design Change Cartridges in Seconds Matched Media & Low Dead Volume Maintain Chromatographic Performance All-Guard Cartridge Holder and Accessories All-Guard Cartridge Holder* Replacement Column Coupler with Tips Replacement Female Tip Replacement Waters Tip *Includes Direct-Connect Column Coupler with tips. Custom Packed Guard Cartridges Change cartridges in seconds without tools Alltech s All-Guard System protects your valuable columns from damaging mobile phase and sample contaminants without changing your separation. Use them with confidence in all your applications. The All-Guard System has only two parts. This elegantly simple solution is less likely to leak and easier to assemble, use, and maintain than other guard cartridge systems. The All-Guard System s unique holder is open on the side for fast installation (Figure 1). Just drop the cartridge in, hand-tighten the holder nut, and connect to your column. Guard cartridges act as an extension of the analytical column. If the guard cartridge's selectivity or efficiency doesn t match the analytical column, performance deteriorates. That's why All-Guard Cartridges are available in over 100 popular packing materials. Fast delivery on custom All-Guard Cartridges is available for media not shown DESCRIPTION QTY PART NO. PRICE All-Guard Custom Cartridges (Requires All-Guard Holder) Custom SS Cartridges 4 C-9800 Specify Material, Particle Size, and ID Custom PEEK Metal-Free Cartridges, 4 C-9400 Specify Material and Particle Size All-Guard Custom Cartridge Specifications Part Number: C-9800 (For SS Cartridges) C-9400 (For PEEK Metal-Free Cartridges) Internal Diameter: 2.1mm, 3.2mm, 4.6mm (For SS Cartridges) 4.6mm (For PEEK Cartridges) Length: 7.5mm Packing Material: Name and Particle Size Figure 1 - Instructions for Alltech All-Guard Cartridge System Step 1: Insert guard cartridge into holder. Step 2: Hand-tighten holder. Step 3: Insert correct tip into direct-connect column coupler depending on column type. Use the black tip for industry standard female, or use the red tip for Waters HPLC Columns. Step 4: Connect All-Guard holder to column using coupler. Connect inlet tubing using any standard fitting. Direct Connect Column Coupler (Part No ) Female Tip - Black (Part No ) All-Guard Holder (Part No ) Waters Tip - Red (Part No )

10 Guard Columns All-Guard Cartridges Alltech All-Guard Cartridges Alltech All-Guard Cartridges (Cont'd) PARTICLE PACKING SIZE QTY PART NO. PRICE Alltech Packings Adsorbosil, 7.5 x 4.6mm C18 5µm C8 5µm C2 5µm CN 5µm NH2 5µm Silica 5µm Adsorbosil, 7.5 x 3.2mm C18 5µm C8 5µm Adsorbosphere, 7.5 x 4.6mm C18 5µm C8 5µm TMS 5µm NH2 5µm Phenyl 5µm Silica 5µm CN 5µm CN-AQ 5µm SAX 5µm SCX 5µm Catecholamine 3µm Nucleotide/Nucleoside 7µm OPA 5µm Adsorbosphere, 7.5 x 3.2mm C18 5µm C8 5µm Adsorbosphere HS, 7.5 x 4.6mm HS, C18 5µm HS, Silica 5µm Adsorbosphere HS, 7.5 x 3.2mm HS, C18 5µm Adsorbosphere UHS, 7.5 x 4.6mm UHS, C18 5µm Adsorbosphere UHS, 7.5 x 3.2mm UHS, C18 5µm Adsorbosphere XL, 7.5 x 4.6mm 90Å C18 5µm Å C18 5µm Å C18-B 5µm Å C8 5µm Å C8 5µm Å TMS 5µm Å Silica 5µm Å SAX 5µm Å SCX 5µm Å HAAX 7µm Adsorbosphere XL, 7.5 x 3.2mm 90Å C18 5µm Å C8 5µm Allsphere, 7.5 x 4.6mm Silica 5µm ODS-1 5µm ODS-2 5µm Octyl 5µm Hexyl 5µm Phenyl 5µm Methyl 5µm Cyano 5µm Amino 5µm SAX 5µm SCX 5µm PARTICLE PACKING SIZE QTY PART NO. PRICE Alltech Packings Alltima, 7.5 x 4.6mm C18 5µm C18-LL 5µm AQ 5µm C8 5µm Phenyl 5µm Silica 5µm CN 5µm NH2 5µm Alltima, 7.5 x 3.2mm C18 5µm C8 5µm Alltima WP, 7.5 x 4.6mm C18 5µm C4 5µm alphabond, 7.5 x 4.6mm C18 5µm C18 10µm C8 10µm Phenyl 10µm CN 10µm NH2 10µm Silica 5µm Silica 10µm Apollo, 7.5 x 4.6mm C18 5µm Phenyl 5µm Silica 5µm Carbohydrate, 7.5 x 4.6mm Amino 10µm Cation 5µm OH-100 Anomer 7µm Econosil, 7.5 x 4.6mm C18 5µm C8 5µm NH2 5µm CN 5µm Silica 5µm Econosil, 7.5 x 3.2mm C18 5µm C8 5µm Econosphere, 7.5 x 4.6mm C18 5µm C8 5µm CN 5µm NH2 5µm Silica 5µm Econosphere, 7.5 x 3.2mm C18 5µm C8 5µm i All-Guard Cartridges Require Holder - Part No

11 Guard Columns All-Guard Cartridges 462 Alltech All-Guard Cartridges (Cont'd) PARTICLE PACKING SIZE QTY PART NO. PRICE Alltech Packings (Cont'd) Macrosphere 300, 7.5 x 4.6mm C18 5µm C8 5µm C4 5µm GPC-300 7µm WAX 7µm WCX 7µm SAX 7µm SCX 7µm Macrosphere 300, 7.5 x 3.2mm C18 5µm C8 5µm C4 5µm Mixed-Mode, 7.5 x 4.6mm RP18/Cation, 100Å 7µm RP8/Anion, 100Å 7µm RP8/Cation, 100Å 5µm Platinum, 7.5 x 4.6mm C18, 100Å 5µm C18, 300Å 5µm C8, 100Å 5µm C8, 300Å 5µm C4, 300Å 5µm Phenyl, 100Å 5µm Cyano, 100Å 5µm NH2, 100Å 5µm SAX 5µm Silica, 100Å 5µm Silica, 300Å 5µm Platinum EPS, 7.5 x 4.6mm C18 EPS, 100Å 5µm C18 EPS, 300Å 5µm C8 EPS, 100Å 5µm C8 EPS, 300Å 5µm C4 EPS, 300Å 5µm Prevail, 7.5 x 4.6mm C18 5µm C8 5µm Phenyl 5µm Cyano 5µm Amino 5µm Silica 5µm OA 5µm Amide 5µm ProSphere, 7.5 x 4.6mm C18, 300Å 5µm C18, 100Å 5µm C4 5µm P 7µm P-HR 4µm ProSphere, 7.5 x 3.2mm C18, 300Å 5µm C4 5µm Beckman Ultrasphere Guard Cartridges DESCRIPTION PARTICLE SIZE QTY PART NO. PRICE Beckman Packings Ultrasphere 7.5 x 4.6mm C18 5µm C18-IP 5µm C8 5µm CN 5µm Silica 5µm i All-Guard Cartridges Require Holder - Part No Benson All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE Benson Packings BC-100, 7.5 x 4.6mm Calcium 10µm Lead 10µm Silver 10µm BC-200, 7.5 x 4.6mm Calcium 10µm Silver 10µm AKZO Nobel All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE AKZO Nobel Packings Kromasil, 7.5 x 4.6mm C18 5µm C8 5µm C4 5µm NH2 5µm Silica-100Å 5µm Silica-60Å 5µm Kromasil, 7.5 x 3.2mm C18 5µm C8 5µm GL Sciences All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE GL Sciences Packings Inertsil, 150Å, 7.5 x 4.6mm C8 5µm Phenyl 5µm Silica 5µm ODS-80Å 5µm ODS-80Å 10µm ODS-2 5µm Hypersil All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE Hypersil Packings Hypersil BDS, 7.5 x 4.6mm C18 5µm C8 5µm Phenyl 5µm CN 5µm Hypersil BDS, 7.5 x 3.2mm C18 5µm C8 5µm Hypersil 120Å, 7.5 x 4.6mm SAS C1 5µm Phenyl-1 5µm Phenyl-2 5µm CPS-1 CN 5µm CPS-2 CN 5µm APS-1 NH2 5µm APS-2 NH2 5µm MOS-1 C8 5µm MOS-2 C8 5µm ODS C18 5µm Silica 5µm Butyl C4 5µm SAX 5µm

12 Guard Columns All-Guard Cartridges Hypersil All-Guard Cartridges (Cont'd) PARTICLE PACKING SIZE QTY PART NO. PRICE Hypersil Packings (Cont'd) Hypersil 120Å, 7.5 x 3.2mm ODS C18 5µm MOS-1 C8 5µm Hypersil 100Å, 7.5 x 4.6mm C18 5µm C8 5µm Silica 5µm Hypersil PEP, 7.5 x 4.6mm µm µm µm µm Hypersil Green, 7.5 x 4.6mm PAH 5µm ENV 5µm Carbamate 5µm Merck KGaA All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE Merck KGaA Packings (Cont'd) LiChrospher, 7.5 x 4.6mm CN 5µm Diol 100 5µm NH2 5µm RP-8 5µm RP-8 Endcapped 5µm RP-Select B 5µm RP-18 5µm RP-18 Endcapped 5µm Si-60 5µm Si-100 5µm LiChrospher, 7.5 x 3.2mm RP-18 5µm RP-8 5µm Macherey-Nagel All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE Macherey-Nagel Packings Nucleosil 100Å, 7.5 x 4.6mm C18 5µm C8 5µm NH2 5µm CN 5µm Phenyl 7µm Silica 5µm Nucleosil 100Å, 7.5 x 3.2mm C18 5µm C8 5µm Waters All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE Waters Packings Waters Spherisorb, 7.5 x 4.6mm ODS-1 5µm ODS-2 5µm C8 5µm C6 5µm NH2 5µm CN 5µm Phenyl 5µm Silica 5µm SAX 5µm Waters Spherisorb, 7.5 x 3.2mm C8 5µm ODS-1 5µm ODS-2 5µm Merck KGaA All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE Whatman All-Guard Cartridges PARTICLE PACKING SIZE QTY PART NO. PRICE Merck KGaA Packings LiChrosorb, 7.5 x 4.6mm Diol 5µm NH2 5µm RP-18 5µm RP-8 5µm RP-Select B 5µm Si-60 5µm LiChrosorb, 7.5 x 3.2mm RP-18 5µm RP-8 5µm Whatman Packings Partisil, 7.5 x 4.6mm ODS 10µm ODS-2 10µm ODS-3 5µm C8 5µm PAC 5µm Silica 5µm SCX 10µm SAX 10µm Partisil, 7.5 x 3.2mm ODS-3 5µm C8 5µm All-Guard Cartridge Holder and Accessories i All-Guard Cartridges Require Holder - Part No DESCRIPTION QTY PART NO. PRICE All-Guard Cartridge Holder (Includes Direct-Connect Column Coupler) Ea Replacement Column Coupler Ea

13 Guard Columns IC All-Guard Cartridges and Prep-Guard Columns All-Guard IC Cartridge System PEEK Cartridges Provide Inert Metal-Free Fluid Path Simple and Convenient Reliable IC guards are available in several packing chemistries to suit most popular IC 5419 columns. The 7.5 x 4.6mm cartridges have adequate capacity to remove contaminants from mobile phase or sample. Contaminated cartridges can be replaced in seconds by hand - no tools are required. Starter Kits include an All-Guard Holder, 1 coupler, and 3 cartridges. For a cross reference to Alltech IC columns see page 555. IC Guard Column Cross Reference Table ALL-GUARD ALL-GUARD COLUMN STARTER KIT KIT MANUFACTURER COLUMN TYPE TYPE PART NO. Dionex IonPac AS4, AS4A, AS4A-SC, GA AS7, AS9, AS10, AS11, AS12, AS14 IonPac CS3, CS10, CS11 GC IonPac CS12, CS14 GC IonPac NS1 GRP IonPac AS1, AS5 GIE Waters IC-Pak -A GA IC-Pak T -M/D GC Ion Exclusion GIE Hamilton PRP -X100 GA PRP -X200 GC PRP -X300 GIE PRP -1 GRP Misc. Sarasep ANIONSEP AN1 GA Bio-Rad, Aminex, HPX-87 GIE Interaction ION-120 GA Interaction ION-210 GC Interaction ORH-801 GIE Metrohm Metrosep GA Metrohm SUPER SEP GC All-Guard IC Columns DESCRIPTION QTY PART NO. PRICE IC Starter Kits (Includes 3 Cartridges, 1 Holder, and 1 Coupler) GA-1 Anion Ea GC-1 Cation Ea GC-2 Universal Cation Ea GIE-1 Ion Exclusion Ea GRP-1 Resin Reversed-Phase Ea GRP-2 Silica Reversed-Phase Ea Replacement Cartridges (Requires Guard Holder) GA-1 Anion GC-1 Cation GC-2 Universal Cation GIE-1 Ion Exclusion GRP-1 Resin Reversed-Phase GRP-2 Silica Reversed-Phase Replacement Parts All-Guard Cartridge Holder* Ea Column Coupler (PEEK) Ea *Includes Copyright 1 column 2003 coupler. Alltech Associates, Inc. New! Prep-Guard Columns Excellent Retention of Soluble and Particulate Contaminants Individually Tested Affordable Price Alltech s Prep-Guard protects your valuable preparative HPLC columns from damaging mobile phases and sample contaminates without changing your separation. Columns last longer and performance is more consistent. Troubleshooting is made easier when peak shapes begin to deteriorate or backpressures increase by simply replacing the guard as a first step in restoring system performance. Every Prep-Guard is individually packed and tested to ensure a consistent, high quality product every time. Connect the Prep-Guard to the column using Alltech's direct-connect column coupler (Figure 1) or with fittings and tubing (Figure 2). All of our most popular prep column packings are offered in a Prep-Guard format. Fast delivery on custom Prep-Guards is available for media not shown, or use one of the general purpose packings to accommodate a wide range of C18 or Silica prep columns. Prep-Guard Columns Dimensions: 7mm ID x 33mm length Material: 316 Stainless Steel, PEEK Max Temperature: 100 C Thread Type: UNF (Industry Standard Ports) Figure 1 - Connect with coupler. Prep-Guard Columns 6286 ALLTECH PACKING PARTICLE SIZE PART NO. PRICE Alltima C18 10µm Alltima Silica 10µm Prevail C18 10µm Prevail Silica 10µm Apollo C18 10µm Apollo Silica 10µm Prosphere C18-300Å 10µm Prosphere C18-100Å 10µm Prosphere C4-300Å 10µm Prosphere P-PREP 5µm Econosphere C18 10µm Econosphere Silica 10µm Econosil C18 10µm Econosil Silica 10µm General Purpose C18 10µm General Purpose C18 Wide Pore 10µm General Purpose Silica 10µm Custom Prep-Guard Any C-6000PG Prep-Guard Accessories Direct-Connect Column Coupler Inline Connector Figure 2 - Connect with fittings and tubing. 464

14 Guard Columns Refillable Refillable Guard Columns Pack Your Own Guard Columns Quickly, Easily, and Economically Analytical and Preparative Guard Columns Available Fill Columns with Your Choice of Packing Alltech's Refillable Guard Columns are inexpensive alternatives to prepacked guard cartridges. These guards are easy to pack and are available in analytical (20mm x 2mm) and preparative (30mm x 9.5mm) scale sizes. The analytical guard columns are available in two formats: Direct-Connect and In-Line. The Direct-Connect guard columns connect to any analytical column using one of the two included color-coded tips which serve as internal tubing and ferrule. An In-Line version is also available for situations where direct attachment is not desirable. The refillable preparative guard columns have an in-line format and are supplied with a universal column coupler for attachment to any column with industry standard female fittings (CPI). Packing the refillable guard column is quick and easy. The porous packing is dry packed. A filling funnel is included with the analytical guard column; the preparative guard column has a larger internal diameter which makes this funnel unnecessary. Complete packing instructions are included. Analytical Direct-Connect Guard Column Kit includes: Two Analytical Refillable Columns (20 x 2mm) 3g of Porous Packing Material (Particle Size Micron) One Filling Funnel Ten 2-Micron Prefilters Complete Instructions Porous Packing Material Refillable Guard Column Kits Analytical Direct-Connect Guard Column Kits C Silica Preparative In-Line Guard Column Kits C Silica Replacement Parts and Accessories Analytical Refillable Guard Columns Direct-Connect Column Hardware (Includes 1 Refillable Guard Column, 2 Color-Coded Tips, 1 Filling Funnel) Spare Tips Direct-Connect Version for Female Fittings (Black), Ea for Waters Fittings (Red), Ea for Valco Fittings (Blue), Ea In-Line Column Hardware, 2mm ID (Includes 1 Refillable Guard Column, 1 Filling Funnel) Spare Analytical Accessories 2µm Frits, 5/pkg µm Frits, 5/pkg Filling Funnel Preparative Refillable Guard Columns In-Line Column Hardware, 9.5mm ID Spare Preparative Accessories 2µm Frits for Preparative Guard, 10/pkg One-Piece Coupler (Female Type B ) Universal Column Coupler Funnel Prefilters 5552 Porous Packing Materials 10G PART NO. PRICE C Silica G Preparative In-Line Guard Column Kit includes: Two Preparative Refillable Columns (30 x 9.5mm) 10g of Porous Media (Particle Size Micron) Column Coupler Four 2-Micron prefilters Complete Instructions Porous Packing Material 5553 Column Coupler Prefilters 465

15 Guard Columns OPTI-GUARD and OPTI-LYNX System OPTI-GUARD Guard Columns Simple Hand-Tight Connection, No Holder Needed Zero Dead Volume Design is Ideal for Use with Micro-LC Columns Depth Filtration Design Compact Size (15mm x 1mm) OPTI-LYNX Guard Column System The OPTI-LYNX Guard Column System combines quick-connect actuation with the convenience of guard cartridges, all in a lowvolume package that will not compromise your separation. Connection paths to the guard cartridge contribute less than 2µL of volume. The OPTI-LYNX Guard Column System fits any analytical column with a inlet port. Holder Cap/Holder Tube Assembly U.S. Patent No and other Patents Pending Guard Column Cartridge Universal Port Adapter 5418 OPTI-LYNX Column Connector Kit Designed in the shape of an HPLC compression fitting, the OPTI- GUARD guard column is simple to use with any analytical column. Its unique design requires no holder, seals, or complicated parts to connect. The innovative 2-piece construction contains a self-adjusting stem that fits any conventional HPLC column. For applications requiring a column oven, the external dimensions of the OPTI- GUARD allow it to be placed in the oven attached to the HPLC column. There are no holders to purchase. The OPTI-GUARD can also be conveniently stored with the analytical column. OPTI-GUARD Design 5µm Frit 2µm Frit 5492 The OPTI-LYNX Column Connector Kit contains everything you need to bring quick-connect capability to your analytical column. Use one Column Connector Kit at the top of the column for fast and easy connection with integral pre-column filtration, and another at the bottom of the column with a sealing element for a straight-through connection to the detector cell. OPTI-LYNX Column Connector Kit with Filter Insert Analytical Column OPTI-LYNX Guard Column System OPTI-LYNX Column Connector Kit with Sealing Element DESCRIPTION QTY PART NO. PRICE OPTI-LYNX Guard Column System* OPTI-GUARD Columns Packing OPTI-GUARD is designed in the shape of an HPLC fitting making it simple to use with any HPLC column OPTI-LYNX Guard Column Cartridges** C18 Ea C8 Ea NH2 Ea Silica Ea Phenyl Ea CN Ea Anion Ea Cation Ea *Includes universal port adapter, guard holder tube, holder cap & fitting. **OPTI-LYNX Guard Column System required. OPTI-LYNX Column Connector Kit PACKING QTY PART NO. PRICE OPTI-GUARD Columns C18 (Violet) C8 (Yellow) Phenyl (Green) CN (Blue) NH2 (Red) Anion Exchanger (Black) Cation Exchanger (White) Silica (Orange) OPTI-LYNX Column Connector Kit* With Sealing Element With 2.0µm Filter Replacement Parts, 10/pkg Sealing Element mm Filter µm Filter *Includes universal port adapter, holder cap/holder tube, fitting, and 1 filter insert or sealing element. 466

16 Alltech High Pressure Fittings SofGrip One-Piece Fittings Graph-Tite Construction is 3X Stronger than PEEK Soft Elastomer Cushion Makes Hand-Tightening Comfortable One-Piece Integrated Ferrule Eliminates Handling Small Pieces Five Colors and Two Lengths Offer HPLC System Organizing Options Other Fittings No-Slip Fittings Alltech s SofGrip HPLC Fittings incorporate an ergonomic element with a rugged high pressure fitting. We start with durable Graph-Tite (graphitized-peek) material which is three times stronger than other polymers, 100% biocompatible, and completely inert to nearly all HPLC and IC solvents. Then we wrap the head of this tough Graph-Tite fitting with a soft elastomer cushion. The result is a reliable finger-tight connection that is extremely comfortable and easy to make. The one-piece integrated ferrule design eliminates the frustration of handling small pieces. Hand tighten SofGrip Fittings into any port, regardless of stop depth, for a leak-free seal up to 5000 psig. These fittings are available as a Standard One-Piece or with Alltech s exclusive No-Slip feature. The No-Slip version incorporates barrel tines (Figure 1) in the bore of the fitting that lightly grip the tubing. This added convenience keeps the fitting in place when changing columns or modifying plumbing (Figure 2). Two lengths and five colors are available in both SofGrip Fitting lines to configure your HPLC system in the most convenient and efficient manner Figure 2 - No-Slip SofGrip Fitting Stays on Tubing Between Connections SofGrip Fittings Material: Graph-Tite (Carbon-Reinforced PEEK) Max. Temperature: 100 C Max. Pressure: 5000psig Thread Type: UNF Typical Use: 1/16" OD Tubing Connections A B 6361 SoftGrip Fittings 4615 Figure 1 - Integral barrel tines in No-Slip fittings lightly grip the tubing, holding the fitting in place between connections 4614 GRAPHIC LENGTH COLOR QTY PART NO. PRICE Standard One-Piece Version A Short Black A Short Red A Short Blue A Short Green A Short Yellow B Long Black A Short Assort No-Slip One-Piece Version A Short Black A Short Red A Short Blue A Short Green A Short Yellow B Long Black A Short Assort

17 Alltech High-Pressure Fittings One-Piece Fittings Color Coded with Non-Extractable Dye Works with All 1/16" OD Tubing and Female Ports 100% PEEK Construction is Inert and Biocompatible Graph-Tite Version is 3X Stronger than PEEK A C B D One-Piece Fittings These bright, colorful fittings clearly identify fluid connections and have all the benefits of standard Finger-Tight Fittings universal application, reliable connections without tools, and inert PEEK or Graph-Tite construction. The 100% PEEK construction is both biocompatible and chemically inert. The non-extractable dyes are clearly visible and will not contaminate your analysis. Graph-Tite One-Piece fittings are made from a carbonreinforced PEEK material that is stronger and more durable than 100% PEEK. For situations involving higher pressures, or cramped connections, hex-head versions are also available GRAPHIC* DESCRIPTION COLOR MAT'L QTY PART NO. PRICE One-Piece Fittings A Short Finger-Tight Natural PEEK A Short Finger-Tight Red PEEK A Short Finger-Tight Yellow PEEK A Short Finger-Tight Blue PEEK A Short Finger-Tight Green PEEK A Short Finger-Tight Black Graph-Tite A Short Finger-Tight Assort* PEEK B Long Finger-Tight Natural PEEK C Short Hex-Head Natural PEEK C Short Hex-Head Black Graph-Tite One-Piece Fittings Material: PEEK or Graph-Tite (Carbon Reinforced PEEK) Max. Temp.: 100 C Max. Pressure: Finger-Tight : 5000psig Wrench-Tight : 8000psig Thread Type: UNF Typical Use: 1/16" OD Tubing Connections D Long Hex-Head Natural PEEK D Long Hex-Head Black Graph-Tite *Assortment includes two of each color. Carbon Reinforced PEEK. Rheodyne ChromTRAC System Makes Fluid Line Identification Easy Allows Hex-Head Fittings to be Finger-Tightened Available in Seven Colors Color code your HPLC fluid connections with Rheodyne s ChromTRAC fitting knobs. These removable, brightly colored knobs fit tightly atop hex-head fittings made by Rheodyne and Alltech. With the ChromTRAC knob installed, a wrench-tight, hex-head fitting becomes a color-coded fingertight fitting. i Do you need to tighten fittings in cramped quarters? Try the Handy-Lok Fitting Wrench, see page ChromTRAC ID Kit DESCRIPTION QTY PART NO. PRICE ID Kit* 20/pkg *4 each of blue, red, yellow; 2 each of grey, green, white, black 468

18 Alltech High-Pressure Fittings No-Slip One-Piece Fittings No-Slip Barrel Tines Keep Fittings on the Tubing Between Connections Combined Nut and Ferrule Eliminates Handling (and Losing) Small Pieces Universal Design Works with All Ports, Regardless of Stop Depth Graph-Tite Version is 3X Stronger than PEEK 4615 Figure 1 - Integral barrel tines lightly grip the tubing, holding the fitting in place between connections Tired of searching the bench or floor looking for a fitting that fell off the tubing? No-Slip Fittings stay on the tubing between connections using barrel tines that lightly grip the tubing (Figure 1). This Alltech exclusive feature keeps the fitting in place when you're changing columns, sample loops, or any other time the fitting is not engaged. No-Slip Fittings are made from PEEK or Graphitized PEEK, inert to nearly all HPLC and IC solvents, and 100% biocompatible. No-Slip Fittings form reliable, leak-free connections with a convenient one-piece design. A knurled, finger-tight handle allows quick and easy connection without tools at pressures up to 5,000psig. For situations involving higher pressures, or cramped connections, hex-head versions are available. No-Slip Fittings work on all ports, and adjust automatically to the correct stop depth every time they're connected. With No-Slip Fittings, you don't need to change tubing and fittings when switching between columns from different manufacturers. A B No-Slip One-Piece Fittings GRAPHIC DESCRIPTION COLOR MATERIAL QTY PART NO PRICE A Short Finger-Tight Black Graph-Tite A Short Finger-Tight Natural PEEK A Short Finger-Tight Green PEEK A Short Finger-Tight Blue PEEK A Short Finger-Tight Yellow PEEK A Short Finger-Tight Red PEEK A Short Finger-Tight Assort* PEEK C D No-Slip One-Piece Fittings Material: PEEK or Graphtite (Carbon Reinforced PEEK) Max. Temp.: 100 C Max. Pressure: Finger-Tight : 5,000psig Wrench-Tight: 8,000psig Thread Type: UNF Typical Use: 1/16" OD Tubing Connection B Long Finger-Tight Black Graph-Tite B Long Finger-Tight Natural PEEK C Short Hex-Head Black Graph-Tite C Short Hex-Head Natural PEEK D Long Hex-Head Black Graph-Tite D Long Hex-Head Natural PEEK * Assortment includes two of each color. Carbon Reinforced PEEK. 469

19 Alltech High-Pressure Fittings Direct-Connect Universal Column Adaptor* Works with Male or Female Fittings Universal Adjusts to HPLC Fitting or Column Seals Finger-Tight to 5,000psig 5428 Alltech s Direct-Connect Universal Column Adaptor is available in PEEK or Graph-Tite material. This fitting allows the connection of any column to the instrument in just seconds without the use of tools. The adaptor takes the place of the stainless steel nut and ferrule that normally connects the column to the instrument. Instead, an inert polymer ferrule/thread combination is used to make the connections. By hand tightening, the ferrule grips the tubing to form a seal leak-free to 5,000psig. Since the polymeric ferrule does not bite or swage the tube, the adaptor is free to adjust to fit any mating fitting instantly! The adaptor is double sided, with a standard male fitting on one end and a female seat on the other to accommodate male fittings. Simply turn it around to change from male to female fittings. The adaptor consists of two parts: a replaceable insert and a reusable knurled stainless steel holder. *U.S. Patent #4,586,733 Two-Piece Finger-Tight Fittings Color Coded Fits all Conventional Port Configurations 100% PEEK Construction Chemically Inert Wing-Nut Design Finger-Tight Operation to 6,000psig Graph-Tite Versions 3X Stronger than Regular PEEK 5427 This fitting is designed to work in virtually any column, valve, union, tee, cross, or other fluid port with internal threads. The wing nut design provides added torque during assembly. This design makes it easier than ever to make and break connections by hand. The nut accepts a PEEK ferrule which locks into the nut upon assembly, forming a single unit which keeps the ferrule from sticking in the mating fitting. The nut may be used again and again. Simply replace the ferrule after every 30 to 40 connections. In addition, both nut and ferrule are interchangeable with other popular finger-tight fittings. The Two- Piece Finger-Tight Fitting is suitable for connections with valves and adaptors with internal threads from any manufacturer. Direct-Connect Universal Column Adaptor Material: PEEK or Graphtite (Carbon Reinforced PEEK) with Stainless Steel Handle Max. Temp.: 100 C Max. Pressure: 5,000psig Thread Type: UNF Typical Use: 1/16" OD Tubing Connections ; Two-Piece Finger-Tight Fittings Material: PEEK or Graphtite (Carbon-Reinforced PEEK) Max. Temp.: 100 C Max. Pressure: 6,000psig Thread Type: UNF Typical Use: 1/16" OD Tubing Connections ;; Connects to female or male endfitting. Alltech Direct-Connect Universal Column Adaptor & Kit Universal Column Adaptor PEEK Graph-Tite * Replacement Inserts PEEK Graph-Tite * Kit (2 Adaptors and 4 Replacement Inserts) PEEK Graph-Tite * *Carbon Reinforced PEEK A Two-Piece Finger-Tight Fittings GRAPHIC COLOR MATERIAL QTY PART NO. PRICE Two-Piece Finger-Tight Fittings with Ferrules A Natural PEEK A Red PEEK A Yellow PEEK A Blue PEEK A Green PEEK A Black Graph-Tite A Assorted* PEEK Replacement Ferrules B PEEK Ferrules PEEK * Assortment includes two of each color. Carbon Reinforced PEEK. B 470

20 Alltech High-Pressure Fittings Two-Piece Double-Sided Ferrule (DSF) Fittings Twice the Gripping Power Suitable For Use with All Threaded Ports and Fittings Available in PEEK & Graph-Tite 5429 A B These fittings use a Double-Sided Ferrule (DSF) that is universal in application and ideal for use with polymeric tubing. By gripping the tubing in two places (see Figure 1), the DSF has increased holding power without concentrating all the force on one area of the tubing. This makes them perfect for use with polymeric tubing such as PEEK or Tefzel, which may be crushed by other fitting systems when tightened for high-pressure applications. Choose either the hex-head or Wrench/Finger-Tight format. The hex-head is compact and recommended for applications with limited space. The Wrench/Finger-Tight combines the convenience of a fingertight fitting with the option of wrench tightening when higher pressures are used. Also, the Wrench/ Finger-Tight is available in a Male-Female version which provides a female thread at one end for connection to male columns (see Figure 2). DSF Fittings are available in PEEK and Graph-Tite. Graph-Tite is a carbon-reinforced PEEK material that is 3x's stronger than natural PEEK, and with improved durability. Graph-Tite fittings come with PEEK Ferrules. Two-Piece Double-Sided Fittings Material: PEEK or Graphtite (Carbon-Reinforced PEEK) Max. Temp.: 100 C Max. Pressure: Finger-Tight 6,000psig Wrench-tight 10,000psig Thread Type: UNF Typical Use: 1/16" OD Tubing Double-Sided Ferrule Grips Tubing in Two Places for Increased Holding Power Figure 1 Figure 2 Male-Female Wrench/Finger-Tight Nut C Two-Piece Double-Sided Ferrule Fittings GRAPHIC COLOR MATERIAL QTY PART NO. PRICE Standard Wrench/Finger-Tight Nuts with Ferrules A Natural PEEK A Black PEEK A Red PEEK A Yellow PEEK A Blue PEEK A Green PEEK A Black Graph-Tite A Assorted* PEEK Male-Female Wrench/Finger-Tight Nuts with Ferrules B Natural PEEK B Black PEEK B Red PEEK B Yellow PEEK B Blue PEEK B Green PEEK B Black Graph-Tite B Assorted* PEEK Long Hex-Head Nuts with Ferrules C Natural PEEK C Black PEEK C Red PEEK C Yellow PEEK C Blue PEEK C Green PEEK C Black Graph-Tite C Assorted* PEEK Short Hex-Head Nuts with Ferrules D Natural PEEK D Black PEEK D Red PEEK D Yellow PEEK D Blue PEEK D Green PEEK D Black Graph-Tite D Assorted* PEEK D E Replacement Ferrules E Ferrules PEEK E Ferrules Kel-F * Assortment includes two of each color. Carbon Reinforced PEEK. 471

21 Alltech High-Pressure Fittings Stainless Steel Hex-Head HPLC Fittings These fitting are offered in various lengths to allow for special needs, such as plumbing a valve. Staggering different lengths of nuts allow wrench access to the fitting without being hindered by adjacent nuts. Stainless Steel Finger-Tight Fittings Make quick, reliable connections to any standard NUF port with finger-tight fittings and ferrules. This two-piece assembly consists of a stainless-steel fitting and a PEEK ferrule. Upon assembly, the ferrule press-fits into the nut holding them together as a single piece, reducing the chance of losing the ferrule on subsequent connections. Stainless Steel Hex-Head Fittings Material: 300 Stainless Steel Maximum Temperature: 500 C Maximum Pressure: 10,000psig Thread Type: UNF for 1/16", 6-32 UNF for 1/32" Typical Use: 1/16" or 1/32" Tubing Connections Stainless Steel Finger-Tight Fittings Material: 300 Stainless Steel and PEEK Maximum Temperature: 100 C Maximum Pressure: 7,000psig Thread Type: UNF Typical Use: 1/16" Tubing Connections A B A B C D E C Stainless Steel Hex-Head Fittings GRAPHIC DESCRIPTION QTY PART NO. PRICE Hex-head Nuts A 1/16" Nut, Short B 1/16" Nut, Long C 1/16" Nut, Extra Long /32" Nut Stainless Steel Finger-Tight Fittings GRAPHIC DESCRIPTION MATERIAL PART NO. PRICE A Finger-Tight Nut SS B Long Finger-Tight Nut SS C Ferrule PEEK Hex-head Female Nuts D 1/16" Nut Ferrules E 1/16" Ferrule /32" Ferrule

22 Alltech Low-Pressure Fittings Flange-Free Fittings Compatible with all 1/4-28 UNF Fitting Systems Connects Directly to any 1/16" or 1/8" OD Tubing Frit-In-Ferrule Option Provides In-Line Filtration The Flange-Free System makes connections to 1/4-28, flatbottomed ports without flanging tools. Hand-tightened connections produce a leak-free seal to 500psig on 1/8" OD Teflon tubing and to 1,000psig on 1/16" OD Teflon tubing. (For higher pressure applications, use Alltech s Flange-Free Plus System listed below.) Hex-head fittings are available for use with harder tubing, such as PEEK, Tefzel, or metals. When a connection is made, the fluid contacts only the tubing and the Flange-Free Ferrule. The ferrules are made of PEEK, Kel-F, or Tefzel highly inert polymers. PEEK ferrules should be used with PEEK or metal tubing and fittings. Kel-F and Tefzel ferrules give the best results with Teflon, Tefzel, or other polymeric tubing. The Frit-In-Ferrule is a new ferrule system for use with Flange- Free Fittings. A small frit is built into the ferrule to give the benefits of in-line filtration, without the inconvenience or added dead-volume of a filter housing. Frits are available in stainless steel or PAT (PEEK Alloyed with Teflon.) U.S. Patent #4,690,437 Flange-Free Fittings Material: Varies, See Price Block Maximum Temperature: 100 C Maximum Pressure: 1/8" 500psig 1/16" 1,000psig Thread Type: 1/4-28 UNF Typical Use: 1/16" or 1/8" OD Tubing Connection A Flange-Free Nuts and Ferrules 1/16"OD TUBING 1/8"OD TUBING GRAPHIC DESCRIPTION QTY PART NO. PART NO. PRICE Finger-Tight Nuts (Delrin ) A White A Black A White, Extra Long A Black, Extra Long B C Improved Pressure Rating with Alltech s Flange-Free Plus Seals Finger-tight to 5,000psig Connects to any Standard 1/4-28 Port Available Only for 1/16" Tubing The Flange-Free Plus Fitting 6260 System improves the pressure rating for connections to a standard 1/4-28 port. A simple, stainlesssteel bushing helps compress the ferrule against the tubing for a secure seal to 5,000psig. And since the fitting does not bind to the bushing, connections are made easily, without twisting your tubing. Flange-Free Plus is available for 1/16" tubing only. The Flange-Free Plus System uses a PEEK ferrule for its liquid seal, maintaining an inert, metal-free fluid path. That PEEK ferrule is held securely in place by the mechanical strength of the stainless-steel bushing. Flange-Free Plus Fittings DESCRIPTION QTY PART NO. PRICE Fitting System Includes 10 each of Fittings, Bushings, and Ferrules Replacement Parts Stainless Steel Bushings PEEK Ferrules Finger-Tight Nuts (PEEK) A Natural A Black A Red A Yellow A Blue A Green A Graph-Tite A Assorted (2 Ea) Hex-Head Nuts B Aluminum B Stainless Steel Flange-Free Ferrules (PEEK) C 1/16" Bore C 1/8" Bore Flange-Free Ferrules (Kel-F ) C 0.3mm Bore C 0.8mm Bore C 1/16" Bore C 1/8" Bore Flange-Free Ferrules (Tefzel ) C 1/16" Bore C 1/8" Bore Frit-in Ferrule Assemblies (PEEK) C with 2µm SS Frit C with 2µm PAT Frit C with 10µm PAT Frit

23 Alltech Low-Pressure Fittings Fittings for Flanged Tubing Flanged fittings are available for use with 1/8" or 1/16" flanged tubing. PEEK, Kel-F, and Nylon versions are available. Both Hex- Head and Finger-Tight versions are available complete with 316 Type stainless steel washers. Pre-Flanged Teflon Tubing Chemically Inert Supplied with 1/4-28 Nylon Fittings Flanged in Place Custom Lengths Available Fittings for Flanged Tubing Material: PEEK, Nylon, or Kel-F with SS Washers Maximum Temperature: 100 C Maximum Pressure: Limited by Tubing Strength Thread Type: 1/4-28 UNF Typical Use: Low Pressure Plumbing Pre-flanged Teflon Tubing Material: Teflon Maximum Temperature: 100 C Maximum Pressure: 0.020" ID, 1200psig 0.030" ID, 900psig 0.063" ID, 400psig 0.100" ID, 300psig Typical Use: Low Pressure Plumbing Pre-Flanged Teflon Tubing A- Hex-Head B - Finger-Tight TUBING DESCRIPTION MATERIAL PART NO. PRICE 5cm 1/16" OD x 0.020" ID Teflon /16" OD x 0.030" ID Teflon /8" OD x 0.063" ID Teflon Fittings for Flanged Tubing C 1/16" 1/8" GRAPHIC DESCRIPTION MATERIAL QTY PART NO. PRICE PART NO. PRICE Fittings for Flanged Tubing (Washer Included) A Natural Kel-F A Natural Nylon A Green Nylon A Red Nylon A Yellow Nylon A Black Nylon A Blue Nylon A Assorted, 2Ea Nylon B Natural PEEK B Green PEEK B Red PEEK B Yellow PEEK B Black PEEK B Blue PEEK B Assorted, 2 Ea PEEK Replacement Washers C 316 SS SS cm 1/16" OD x 0.020" ID Teflon /16" OD x 0.030" ID Teflon /8" OD x 0.063" ID Teflon cm 1/16" OD x 0.020" ID Teflon /16" OD x 0.030" ID Teflon /8" OD x 0.063" ID Teflon cm 1/16" OD x 0.020" ID Teflon /16" OD x 0.030" ID Teflon /8" OD x 0.063" ID Teflon cm 1/16" OD x 0.020" ID Teflon /16" OD x 0.030" ID Teflon /8" OD x 0.063" ID Teflon Custom 1/16" OD x 0.020" ID Teflon C-201 1/16" OD x 0.030" ID Teflon C-202 1/8" OD x 0.063" ID Teflon C-204 1/8" OD x 0.100" ID Teflon C

24 Alltech Low-Pressure Fitting Accessories Easy-Flange Flanging Tool Uses Mechanical Force to Form Flanges No Electricity or Heat Required! Forms Perfect Flanges on ANY 1/16", 3/32" or 1/8"OD Teflon or thin-walled PEEK Tubing Completely Portable Use it Anywhere in Your Lab Easy-Flange is the first truly convenient tool for making flanges on Teflon tubing. Using mechanical force only (no electricity or heat required), Easy-Flange forms perfect flanges on any Teflon tubing with an OD between 1/16" and 1/8". And now, a sturdier design allows the flanging of thin walled (0.015" maximum wall thickness) PEEK tubing. Simply cut the tubing to the desired length (a Clean-Cut tubing cutter is included), place a fitting on the tubing, slide the tubing into the Easy-Flange body, and form the flange using the flange-rolling tool. The entire operation takes just seconds and produces flanges with superior sealing characteristics compared to flanges formed by conventional methods. New! Low Pressure In-Line Quick Connect Make and Break 1/16 or 1/8 Tubing Connections Quickly and Easily Eliminate Wear and Tear on Fittings and Ferrules Highly Inert PEEK Construction Alltech s Low Pressure In-Line Quick Connect allows fast, effortless connection of 1/16" or 1/8" tubing where 1/4-28 fittings are used. Made from high quality PEEK, the Quick Connect withstands repetitive connections and is compatible with a wide range of solvents. The 1/16" Quick Connect withstands pressures up to 1000psig, and 1/8" Quick connect withstands pressures up to 500psig. Quick Connect 6156 Suggested Quick Connect Usage: Perfect for plumbing low and medium pressure LC systems Use with any low pressure switching valve Quickly swap mobile phase bottles from LC system or filtration equipment Make and break connections to an online degasser Low Pressure In-Line Quick Connect The Easy-Flange clamp holds your tubing securely, while a flange is formed at the end. Easy-Flange Easy-Flange Easy-Flange Flanging Tool Includes: Clean-Cut Tubing Cutter and insert disks 35908, 35907, 35906, 35910, Replacement Disk with: 1.5mm Pin (Polymer) mm Pin (Polymer) mm Pin (Titanium) mm Pin (Polymer) mm Pin (Polymer) mm Pin (Titanium) mm Pin (Titanium) Clean-Cut Tubing Cutter Replacement Blade (for Part No ) /16" Quick Connect /8" Quick Connect

25 Alltech Low-Pressure Adaptors and Plugs Adaptors and Plugs for 1/4-28 Fittings Chemically Inert 1/4-28 Threaded Ports For Use with Flange-Free or Flanged Fittings A B 5461 Low Pressure Adaptors and Plugs Material: Varies, See Price Block Maximum Temperature: 100 C Maximum Pressure: Limited by Fittings Thread Type: 1/4-28 UNF C 1/4-28 Low Pressure Adaptors and Plugs PHOTO DESCRIPTION MATERIAL QTY PART NO. PRICE Unions A PEEK Union PEEK Ea B Bulkhead Union PEEK Ea C Waters Pump Tubing Union PEEK Ea D E Tees D 0.8mm Bore Tee PEEK Ea D 1.5mm Bore Tee PEEK Ea F G H Crosses E 0.8mm Bore Cross PEEK Ea E 1.5mm Bore Cross PEEK Ea Male 1/4-28 Adaptors F Male 1/4-28 to Male Luer Tefzel Ea G Male 1/4-28 to Female Luer Tefzel Ea H Male 1/4-28 to Slip-Fit* PEEK Ea I Male 1/4-28 to 1/4" OD Tube SS Ea J Male 1/4-28 to 1/8" OD Tube SS Ea K Male 1/4-28 to Female PEEK Female 1/4-28 Adaptors L Female 1/4-28 to 1/8"MPT Brass Ea M Female 1/4-28 to Female SS Ea N Female 1/4-28 to Male SS Ea O Female 1/4-28 to Female PEEK P Female M6 to Female PEEK Ea Plugs Q Natural PEEK Q Black PEEK Q Red PEEK Q Yellow PEEK Q Blue PEEK Q Green PEEK Q Assorted (2 Ea) PEEK R White Nylon R White Kel-F *Slip-Fit fits 1/16" to 5/32" ID tubing. Slip-Fit Waters pump tubing to left side of union, and connect standard 1/8" or 1/16" OD tubing to right side of union. I J K L M N O P Q R 476

26 Alltech High- and Low-Pressure Adaptors PEEK Port Adaptors These adaptors connect standard LC fittings to standard LC ports. They are available with 1/4-28, M6, or threads (configured for CPI Standard or Waters). PEEK Luer Adaptors Male and female luer adaptors connect luer fittings, 10-32, 1/4-28 and M6 threaded fittings. All of the luer adaptors are 100% PEEK, making them ideal for a variety of applications. LUER TYPE EXTERNAL THREAD TYPE INTERNAL PORT TYPE Male Female M6 1/4-28 UNF Waters ( C ) CPI Standard ( B ) A B C D E F CPI Standard ( B ) Waters ( C ) 1/4-28 UNF M Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Part No Port Adaptors Material: PEEK Maximum Temperature: 100 C Maximum Pressure: Varies Thread Type: Varies, See Price Block PEEK Port Adaptors GRAPHIC EXTERNAL INTERNAL COORDINATE THREAD TYPE PORT TYPE PART NO. PRICE A2 CPI Standard Waters Style A3 CPI Standard 1/4-28 UNF A4 CPI Standard M B1 Waters Style CPI Standard B3 Waters Style 1/4-28 UNF B4 Waters Style M C1 1/4-28 UNF CPI Standard C2 1/4-28 UNF Waters Style C4 1/4-28 UNF M D1 M6 CPI Standard D2 M6 Waters Style D3 M6 1/4-28 UNF Luer Adaptors Material: PEEK Maximum Temperature: 100 C Maximum Pressure: 100psig Thread Type: Varies, See Price Block PEEK Luer Adaptors GRAPHIC INTERNAL COORDINATE LUER TYPE PORT TYPE PART NO. PRICE E1 Female Luer Female E3 Female Luer 1/4-28 Female E4 Female Luer M6 Female F1 Male Luer Female F3 Male Luer 1/4-28 Female F4 Male Luer M6 Female

27 Alltech High-Pressure Adaptors Universal Direct-Connect Column Coupler (DCCC) The Universal DCCC (Graphic A) will connect any two columns, regardless of fitting type. It consists of a threaded handle that accepts any of three Kel-F tips (Graphic B) on either side. Each tip is proportioned to mate with a particular column port configuration. By selecting the correct tip, columns of any fitting type may be joined without tubing. Universal One-Piece Coupler Alltech now offers a universal one-piece column coupler which will adapt to the stop depth of any port, including industry standard, Waters and Valco. Each side of the coupler adjusts and bottoms out in the port to ensure that minimal dead volume is created when coupling two columns, a guard to a column, or a column to an instrument port. All wetted parts are PEEK for optimal inertness. The color-coded sleeve indicates the coupler ID. Interchangeable Tips Waters Stainless Steel Body Interchangeable Tips Waters Female Female 6362 A Universal One-Piece Coupler B DESCRIPTION COLOR PART NO. PRICE.005" ID Red " ID Yellow " ID Blue " ID Orange Universal Direct-Connect Column Couplers GRAPHIC DESCRIPTION COLOR MATERIAL PART NO. PRICE Universal Direct-Connect Column Coupler (DCCC) A Universal Type SS Body/ Kel-F Tips Replacement Tips B Waters ( C ) Red Kel-F B Female ( B ) Black Kel-F B Valco Blue Kel-F One-Piece Couplers One-Piece Couplers are made from a threaded piece of PEEK with a non-wetted Delrin handle. These types are not capable of universal applications since the tip sizes are fixed, yet they provide a reliable connection when used with matching columns. Column Coupler Kits Coupler Kits are available in either stainless steel or PEEK. The kit includes UNF connecting fittings along with a 5cm 1/16" OD x 0.010" ID tubing. One-Piece Column Couplers 5441 Stainless Steel Female to Female 5442 DESCRIPTION COLOR MATERIAL PART NO. PRICE Female Type Black Delrin /PEEK Waters Type Red Delrin /PEEK Male Type Red Delrin /PEEK Valco Type Blue Delrin /PEEK Female to Waters Coupler Delrin /PEEK PEEK Female to Female Column Coupler Kits Stainless Steel Female to Female 9549 PEEK Female to Female

28 Alltech High-Pressure Adaptors and Plugs Stainless Steel Adaptors and Plugs Interchangeable with Most Fitting Systems Economical Stainless Steel Adaptors and Plugs Material: 300 Stainless Steel Max. Temperature: 500 C with SS Ferrules 100 C with PEEK Ferrules Max. Pressure: 10,000psig with SS Ferrules 8,000psig with PEEK Ferrules Bore Size: Varies Thread Type: UNF Typical Use: 1/16 OD Tubing PEEK Adaptors and Plugs Chemically Inert CPI Standard Port PEEK Adaptors and Plugs Material: PEEK Maximum Temperature: 100 C Maximum Pressure: 8,000psig Bore Size: 0.25mm (0.010") Thread Type: UNF Typical Use: 1/16" OD Tubing A A B C D E F G B C H I J Stainless Steel Adaptors, Plugs, and Caps D GRAPHIC DESCRIPTION MATERIAL QTY PART NO. PRICE Ferrules A Ferrules SS A Ferrules PEEK Unions B Female SS Ea B Waters Union SS Ea C Male Union SS Ea D Male to Female Union SS Ea E Knurled Female SS Ea Bulkhead Union F Bulkhead Union SS Ea Tee G 1/16" Tee SS Ea Standard Plugs, 7,000psig H 1/16" SS Ea High-Pressure Plugs, 10,000psig I 1/16" SS Ea Standard Cap J 1/16" SS Ea E PEEK Adaptors, Plugs, and Caps GRAPHIC DESCRIPTION MATERIAL QTY PART NO. PRICE High Pressure Unions, Tees and Crosses A Union PEEK Ea B Tee PEEK Ea C Cross PEEK Ea D Bulkhead Union PEEK Ea Cap E White Nylon Plugs F Blue Delrin F Black Delrin F White Delrin F Red Delrin F Yellow Delrin F Green Delrin F 479

29 SSI High-Pressure Fittings Nuts and Ferrules 5/16" Hex Head 316 Stainless Steel 6,000psig Pressure Rating A B The larger thread used in this design virtually eliminates twisting the nut off and ruining a valuable part. The SSI nut also features a cupped rather than a flat bottom to grasp and center the ferrule. This insures proper make-up and prevents the ferrule from expanding and locking into the seat under very high torque. Adapter Couplings Stainless Steel Couplers Connect 1/4-28 SSI Fittings to Other Fitting Types Zero-dead volume adaptor couplings for connecting SSI to Waters, male and female CPI type, and to flanged plastic fittings are available. The maximum internal volume of these special adapters is only 0.12 microliters. Couplings C Very low volume couplings are available in a variety of sizes. Use the lower cost coupling with 0.043" diameter through-hole for connecting tubes at high pressure ahead of the sample injector. Couplings with 0.015" through-holes are recommended for all other applications. Special couplings for connecting SSI to Waters and to flanged plastic fittings are also available. H I J Waters # Flange-Type # CPI Male # Tees and Crosses SSI Fittings Material: 300 Stainless Steel Maximum Temperature: 500 C Maximum Pressure: 6,000psig Thread Type: 1/4-28 UNF for 1/16" Nut 3/8-24 UNF for 1/8" Nut Typical Use: 1/16" or 1/8" OD Tubing D Tees and Crosses are special couplings that have many LC applications including two pump gradient formation, pressure gauge connection, parallel column and detector connection, stream splitting, chemical reaction detectors, fraction collection, and many others. Tees and crosses with a 0.043" through-hole should be used for noncritical areas ahead of the sample injector, while those with 0.015" through-hole should be selected for connecting LC columns, detectors, and fraction collectors. Plugs and Caps To seal open female ports or unconnected male fittings. E SSI Fittings GRAPHIC DESCRIPTION/SIZE BORE QTY PART NO. PRICE Nuts and Ferrules A Gland Nut, 1/16" A Gland Nut, 1/8" B Ferrule,1/16" B Ferrule, 1/8" Couplings C 1/16" 0.043" Ea C 1/16" 0.015" Ea C 1/16" 0.010" Ea Tees and Crosses D Tee, 1/16" 0.043" Ea D Tee, 1/16" 0.015" Ea E Cross, 1/16" 0.043" Ea F G Plugs and Caps F 1/16" Plug (Nut Required) G 1/16" Cap (Nut & Ferrule Required) Ea Adapter Couplings H SSI to Waters Ea I SSI to Flange-Type Ea J SSI to CPI Ea

30 Valco High-Pressure Fittings Valco Tees and Crosses 300 Series Stainless Steel Valco Unions 300 Series Stainless Steel Nuts and Ferrules Included G H A B Valco Tees, and Crosses GRAPHIC SIZE BORE PART NO. PRICE Tees A 1/32" 0.25mm A 1/16" 0.25mm A 1/8" 0.75mm A 1/8" 2.0mm I Crosses B 1/32" 0.25mm B 1/16" 0.75mm J K Valco Nuts and Ferrules Valco Ferrules Suitable with Glass-Lined Tubing Valco Nuts and Ferrules Material: Maximum Pressure: Typical Use: C D E Valco Nuts and Ferrules 316 Stainless Steel, PEEK, or PTFE 10,000psig (SS), 8,000psig (PEEK and PTFE) F High Pressure Tubing Connections Valco Unions GRAPHIC SIZE BORE PART NO. PRICE Internal Unions G 1/16" 0.25mm G 1/16" 0.50mm G 1/16" 0.75mm G 1/16" 1/16" G 1/8" 2.0mm G 1/8" 1/8" External Unions H 1/8" 2.0mm Internal Reducing Unions I 1/16" to 1/32" 0.25mm I 1/8" to 1/16" 0.25mm I 1/8" to 1/16" 0.75mm I 1/4" to 1/8" 1/8" GRAPHIC DESCRIPTION QTY PART NO. PRICE Stainless Steel Nuts C 1/32" Nut C 1/16" Nut C 1/8" Nut Stainless Steel Ferrules D 1/32" (Type 303) D 1/16" (Type 316) D 1/8" (Type 316) External/Internal Reducing Unions J 1/8" to 1/16" 1/16" J 1/4" to 1/8" 2.0mm J 1/4" to 1/8" 1/8" Column Endfittings K 1/4" to 1/16" 2.1mm K 1/4" to 1/16" 3.0mm PEEK Ferrules E 1/32" E 1/16" E 1/8" PTFE Ferrules F 1/32" F 1/16" F 1/8"

31 Alltech Fittings Kits High Pressure LC Fittings Kits Common HPLC Accessories Available in One Convenient Kit Alltech fittings kits incorporate the most useful fittings you need without including obscure parts that you will never use. Conveniently stored in one place, you will always find what you need to keep your system running. Kits are available for a variety of instruments and include fittings, tubing, and even a pair of tweezers for small, hard-tohandle parts, such as ferrules Use the chart below and on the next page to determine how many of each product are included in the various fittings kits. All kits (except low pressure) come complete with 30 pieces of EDM- Cut SS tubing in sizes shown on page 483. Alltech Fittings Kits ABI or Kratos Beckman Gilson Hitachi Perkin-Elmer Rainin Rheodyne Valve Shimadzu Spectra-Physics Universal Varian Waters Fittings Kits REPLACEMENT COMPONENT DESCRIPTION PART NO MATERIAL ABI/KRATOS Nuts Universal SS Male Nut SS Two-Piece Finger-Tight PEEK Std. Wrench/Finger-Tight PEEK 5 Univ. Wrench/Finger-Tight PEEK 5 5 1/16" Flange-Free (1/4-28) Delrin /8" Flange-Free (1/4-28) Delrin 5 Ferrules Universal SS Ferrule SS Ferrule for Two-Piece Finger-Tight PEEK Double-Sided Ferrule PEEK /16" Flange-Free Ferrule Kel-F /8" Flange-Free Ferrule Kel-F 5 Plugs Plug 8872 Delrin /4-28 Plug Nylon 2 BECKMAN GILSON* HITACHI PERKIN-ELMER SSI Products Nut SS 6 4 Ferrule SS 6 4 Union SS 1 Rheodyne Products Bushing SS Long Bushing SS Extra-long Bushing SS Ferrule SS Unions PEEK Female Union PEEK *With Rheodyne Valve. 482

32 Alltech Fittings Kits All kits*, come complete with 5 pieces of EDM-Cut SS Tubing in each of the following sizes: 0.010" ID x 5cm " ID x 5cm " ID x 10cm " ID x 10cm " ID x 20cm " ID x 20cm *Excludes Low Pressure Kit Fittings Kits REPLACEMENT COMPONENT DESCRIPTION PART NO. MATERIAL Nuts Universal SS Male Nut SS Long Universal SS Male Nut SS One-Piece Fitting PEEK 2 Long Finger-Tight One-Piece PEEK 2 Two-Piece Finger-Tight PEEK Std. Wrench/Finger-Tight PEEK 4 Univ. Wrench/Finger-Tight PEEK /16" Flange-Free (1/4-28) Delrin Ferrules Universal SS Ferrule SS Ferrule for Two-Piece Finger-Tight PEEK Double-Sided Ferrule PEEK /16" Flange-Free Ferrule Kel-F Plugs Plug 8872 Delrin SSI Products Nut SS 4 5 Ferrule SS 4 5 Rheodyne Products Bushing SS Long Bushing SS Extra-long Bushing SS Ferrule SS Unions SS Male Union SS 1 1 PEEK Female Union PEEK Waters Female Union SS 1 RAININ* RHEAODYNE SHIMADZU SPECTRA-PHYSICS* UNIVERSAL VARIAN** WATERS Adaptors Universal Column Adaptor PEEK/SS 1 1 *With Rheodyne Valve. **With Valco Valve. Low Pressure LC Fittings Kits Flange-Free Kit Fittings, Ferrules, and Unions For Low-Pressure Connections to 1/4-28 Threaded Ports For 1/16" and 1/8" OD Tubing Low Pressure Fittings Kits Flange-Free Kit Includes: 10 Unions (20052) 60 1/16" Flange-Free Nuts (20228) 60 1/8" Flange-Free Nuts (37070) 60 1/16" Flange-Free Ferrules (20115) 60 1/8" Flange-Free Ferrules (20125)

33 Alltech Start-Up Packages Ordering all the supplies necessary to install an HPLC system and keep it running can be a daunting task. Rely on these preassembled packages to take the guesswork out of it. The Basic Start-Up Package provides ONLY the basic products which are required. No frills and no unnecessary cost. The Advanced Start-Up Package is intended to keep your HPLC consumables stocked for some time with products that maximize system efficiency. It replaces some basic consumables with ones that offer more convenience to the busiest labs. The Mobile Phase Delivery Package bundles everything necessary to deliver mobile phase to a binary HPLC system. Purchasing a package saves you the indicated percentage compared to individual component list prices. Basic Start-Up Package Components 6283 Advanced Start-Up Package Components 6282 Save 20% Basic Start-Up Package (Part No ) Save 25% Advanced Start-Up Package (Part No ) COMPONENT DESCRIPTION QTY PART NO. PRICE Basic Start-Up Package COMPONENT DESCRIPTION QTY PART NO. PRICE Advanced Start-Up Package Individual Componets Short PEEK Hex-Head Nuts/Ferrules Long PEEK Hex-Head Nuts/Ferrules Short PEEK Finger-Tight One Piece* PEEK 1/8" Flange-Free Nuts Tefzel 1/8" Flange-Free Ferrules /16" x ID PEEK Tubing 10ft /16" x ID PEEK Tubing 10ft /8" x ID TFE Tubing 10ft Plastic Tubing Cutter Replacement Blade SS 10µm Solvent Inlet Filter µL Flex Connect Sample Loop Open-End Wrench, 1/4" x 5/16" PEEK Union Individual Componets Short PEEK Hex-Head Nuts/Ferrules Long PEEK Hex-Head Nuts/Ferrules Short PEEK Finger-Tight No-Slip Fitting* Long PEEK Finger-Tight No-Slip Fitting PEEK 1/8" Flange-Free Nuts Kel-F 1/8" Flange-Free Ferrules /16" x 0.020" ID PEEK Tubing 20ft /16 x 0.005" ID PEEK Tubing 20ft /8 x 0.063" ID TFE Tubing 10ft Clean-Cut Tubing Cutter Replacement Blade µm PAT Last-Drop MP Inlet Filter In-Line Filter, 2µm Replacement Filter Elements µL Flex Connect Sample Loop µL Flex-Connect Sample Loop Handy-Lok Fitting Wrench Open-End Wrench, 1/4" x 5/16" PEEK Union *Assorted Colors Save 5% Mobile Phase Delivery Package (Part No ) COMPONENT DESCRIPTION QTY PART NO. PRICE Mobile Phase Delivery Package Mobile Phase Delivery Package Components 6284 Individual Componets PEEK 1/8" Flange-Free Nuts Kel-F 1/8" Flange-Free Ferrules /8" x 0.063" ID TFE Tubing 10ft µm PAT Last-Drop MP Inlet Filter L Safety-Coated Glass GL-45 Bottle with Storage Cap 3-Hole Solvent Delivery Cap, Top Threads

34 Tefzel, Teflon, and No-OX Tubing Tefzel Tubing Higher Pressure Rating Alltech Color-Coded Teflon Tubing Color-Coding for Easy Identification of ID Tefzel Tubing Material: Tefzel Maximum Temperature: 100 C Maximum Pressure: Varies by Size, See Price Block Typical Use: Low Pressure Plumbing Teflon Tubing Material: Teflon Maximum Temperature: 100 C Maximum Pressure: Varies by Size, See Price Block Typical Use: Low Pressure Plumbing Tefzel Tubing DIMENSIONS LENGTH PSIG PART NO. PRICE 1/16" OD x 0.007" 10' ' /16" OD x 0.010" 10' ' /16" OD x 0.020" 10' ' /16" OD x 0.030" 10' ' Alltech Color-Coded Teflon Tubing DIMENSIONS COLOR LENGTH PSIG PART NO. PRICE 1/16" OD x 0.010" ID Blue 10' ' /16" OD x 0.020" ID Orange 10' ' /16" OD x 0.030" ID Green 10' ' Teflon Tubing Maximum Inertness Teflon Tubing Material: Teflon Maximum Temperature: 100 C Maximum Pressure: Varies by Size, See Price Block Typical Use: Low Pressure Plumbing 5531 Alltech NO-OX Tubing Easy to Install and Use Eliminates Regassing without Sacrificing Inertness Flexible, Convenient, and Versatile 5533 Alltech NO-OX Tubing has a double wall to prevent mobile phase regassing on any LC system, no matter what degassing method you use. The inert inner Teflon wall carries the mobile phase. The non-wetted outer wall is made from a translucent, flexible polymer with extremely low gas permeability. NO-OX cuts regassing rates to negligible levels, while preserving Teflon s chemical resistance, visibility, and handling properties. Teflon Tubing DIMENSIONS LENGTH PSIG PART NO. PRICE 1/16" OD x 0.007" ID 10' ' /16" OD x 0.010" ID 10' ' /16" OD x 0.020" ID 10' ' /16" OD x 0.030" ID 10' ' /16" OD x 0.040" ID 10' ' /8" OD x 0.063" ID 10' ' /8" OD x 0.100" ID 10' ' " OD x 0.125" ID 10' ' Alltech NO-OX Tubing DESCRIPTION QTY PART NO. PRICE Tubing 1/8"OD x 1.5mm ID 10ft /8"OD x 1.5mm ID 50ft NO-OX Fittings Kit 1/ Nuts, 10 Ferrules, 10 Inserts i For more information on NO-OX Fittings, see page

35 PEEK Tubing Alltech Color-Coded PEEK Tubing Easy to Cut with Razor Blade or Alltech Tubing Cutter High Strength Polymer Replaces Stainless Steel Chemically Inert and Biocompatible PEEK (polyetheretherketone) tubing is the ideal metal-free tubing for high pressure applications. Its mechanical strength, chemical resistance, and biocompatibility are properties that make it appropriate for a wide variety of LC applications. Alltech PEEK Tubing Material: PEEK Maximum Temperature: 100 C Maximum Pressure: Varies by Size, See Price Block Typical Use: High Pressure Plumbing 5535 Striped PEEK Tubing No Dye Contacts Fluid Path Striped PEEK Tubing PRESSURE RATING SOLID COLOR TUBING OD X ID (PSIG) QTY PART NO. PRICE Red 1/16" x 0.005" 7,000 10ft (3.05M) ft (15.25M) Solid Color PEEK Tubing Entire Tube is Colored for Faster Identification Solid Color PEEK Tubing PRESSURE RATING SOLID COLOR TUBING OD X ID (PSIG) QTY PART NO. PRICE Red 1/16" x 0.005" 7,000 10ft (3.05M) ft (15.25M) Yellow 1/16" x 0.007" 7,000 10ft (3.05M) ft (15.25M) Blue 1/16" x 0.010" 5,000 10ft (3.05M) ft (15.25M) Orange 1/16" x 0.020" 5,000 10ft (3.05M) ft (15.25M) Green 1/16" x 0.030" 4,000 10ft (3.05M) ft (15.25M) Yellow 1/16" x 0.007" 7,000 10ft (3.05M) ft (15.25M) Blue 1/16" x 0.010" 5,000 10ft (3.05M) ft (15.25M) Orange 1/16" x 0.020" 5,000 10ft (3.05M) ft (15.25M) Green 1/16" x 0.030" 4,000 10ft (3.05M) ft (15.25M) Grey 1/16" x 0.040" 3,000 10ft (3.05M) ft (15.25M) Black 1/16" x 0.055" 1,000 10ft (3.05M) ft (15.25M) Natural 0.071" x 0.010" 5,000 10ft (3.05M) ft (15.25M) " x 0.020" 5,000 10ft (3.05M) ft (15.25M) " x 0.030" 4,000 10ft (3.05M) ft (15.25M) /8" x 0.062" 5,000 10ft (3.05M) ft (15.25M) /8" x 0.080" 3,000 10ft (3.05M) ft (15.25M)

36 Flex-Connect Tubing Alltech Flex-Connect Tubing Self-Adjusting Length Will Not Bend or Kink Made of PEEK Biocompatible and Chemically Inert Fittings Included Flex-Connect Tubing is the most convenient way to connect components on your HPLC or IC system. The coiled format provides 5527 flexibility for easy installation and springs back to keep excess tubing out of your way. Each piece has 6" of straight tubing at each end and comes with two Hex-Head Fittings and two Double-Sided Ferrules for a reliable connection to any standard port. Flex-Connect is ideal for modular LC systems, giving you the freedom to move components without breaking connections. Striped Flex-Connect Tubing No Dye Contacts Fluid Path Striped Flex-Connect PEEK Tubing PRESSURE RATING SIZE STRIPED COLOR TUBING DIMENSIONS (PSIG) RANGE* PART NO. PRICE Red 1/16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm Yellow 1/16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm Flex-Connect Tubing stretches to make connections easier. Alltech Custom Flex-Connect Tubing Custom Flex-Connect Tubing C Please specify the following: Color Coding (Solid or Striped) ID (0.005" ") Extended Length (cm, 800cm max.) Solid Color Flex-Connect Tubing Entire Tube is Colored for Fast Identification Solid Color Flex-Connect PEEK Tubing PRESSURE RATING SIZE SOLID COLOR TUBING DIMENSIONS (PSIG) RANGE* PART NO. PRICE Red 1/16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm /16" OD x 0.005" 7, cm Yellow 1/16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm /16" OD x 0.007" 7, cm Blue 1/16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm Blue 1/16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm /16" OD x 0.010" 5, cm Orange 1/16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm Orange 1/16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm /16" OD x 0.020" 4, cm Green 1/16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm Green 1/16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm /16" OD x 0.030" 4, cm *Size range indicates where coil is completely retracted and pulled to a comfortable distance. Excludes 6" straight piece on each end. Natural 1/8" OD x 0.062" 2, cm /8" OD x 0.062" 2, cm /8" OD x 0.062" 2, cm /8" OD x 0.080" 2, cm /8" OD x 0.080" 2, cm /8" OD x 0.080" 2, cm *Size range indicates where coil is completely retracted and pulled to a comfortable distance. Excludes 6" straight piece on each end. 487

37 Stainless Steel Tubing Hi-EFF Grade Stainless Steel Tubing Hi-EFF grade stainless steel tubing is especially tempered for easy bending and is washed with acetone to remove any residual materials. Type 316 is the most commonly used stainless steel for LC, suitable for a variety of plumbing applications. Type 304 stainless steel is not appropriate for aggressive liquid environments, but is applicable in a wide variety of GC applications, including plumbing and column fabrication. Standard Stainless Steel Tubing Type 316 Available in 1/32" and 1/16" ODs Ideal for LC Use Type 304 Available in 1/8", 3/16", 1/4" and 3/8" ODs for GC Plumbing 5537 Hi-EFF Stainless Steel Tubing Material: 300 Series Stainless Steel Maximum Temperature: 500 C Maximum Pressure: Varies according to ID* Typical Use: High-Pressure Plumbing *Request datasheet 3005D for more information. Hi-EFF Grade Stainless Steel Tubing 5562 Standard Stainless Steel Tubing Material: 300 Series Stainless Steel Maximum Temperature: 500 C Maximum Pressure: Varies according to ID* Typical Use: High-Pressure Plumbing *Request datasheet 3005D for more information. Standard Stainless Steel Tubing MATERIAL DIMENSIONS UNIT OF MEASURE PART NO. PRICE Type 304 1/8" OD x 0.085" ID per ft (30.5cm) (3.18mm x 2.16mm) 50' (15.26M) 3010 MATERIAL DIMENSIONS UNIT OF MEASURE PART NO. PRICE Type 304 1/8" OD x 0.085" ID per ft (30.5cm) (3.18mm x 2.16mm) per meter 50' (15.26M) /4" ODx 0.210" ID per ft (30.5cm) (3.18mm x 2.16mm) per meter 50' (15.26M) /16" OD x 0.147" ID per ft (30.5cm) (4.76mm x 3.73mm) 50' (15.26M) /4" OD x 0.210" ID per ft (30.5cm) (6.35mm x 5.33mm) 50' (15.26M) /8" OD x 0.305" ID per ft (30.5cm) (9.53mm x 7.75mm) 40' (12.20M) 3032 Type 316 1/8" OD x 0.085" ID per ft (30.5cm) (3.18mm x 2.16mm) per meter ' coil (15.25M) /4" OD x 0.210" ID per ft (30.5cm) (6.35mm x 5.33mm) per meter 50' (15.26M) Type 316 1/32" OD x 0.007" ID per ft (30.5cm) 8195 (0.79mm x 0.18mm) 50' (15.26M) /16" OD x 0.004" ID per ft (30.5cm) (1.59mm x 0.10mm) 50' (15.26M) /16" OD x 0.007" ID per ft (30.5cm) (1.59mm x 0.18mm) 50' (15.26M) /16" OD x 0.010" ID per ft (30.5cm) (1.59mm x 0.25mm) 50' (15.26M) /16" OD x 0.020" ID per ft (30.5cm) (1.59mm x 0.51mm) 50' (15.26M) /16" OD x 0.030" ID per ft (30.5cm) (1.59mm x 0.76mm) 50' (15.26M) /16" OD x 0.040" ID per ft (30.5cm) (1.59mm x 1.02mm) 50' (15.26M) /16" OD x 0.050" ID per ft (30.5cm) (1.59mm x 1.27mm) 50' (15.26M)

38 Stainless Steel Tubing EDM-Cut Stainless Steel Tubing Highly Polished, Burr-Free Ends Low Volume Connections Ultrasonically Cleaned and Passivated 1/16" OD Alltech capillary stainless steel tubing is cut using an Electronic Discharge Machine (EDM) to provide a finish not possible with mechanical cutting methods. As the microphotographs below show, Alltech EDM cut tubing ends are square, burr-free, highly polished, and free of distortion on the tube ID. Connections made with EDM cut tubing have the lowest volume possible. Alltech EDM-cut tubing is supplied ultrasonically cleaned and passivated and can be used immediately without pretreatment. Color-coded caps keep contaminants out and identify the internal diameter of the tubing. EDM-Cut Tubing Material: 316 Grade Stainless Steel Maximum Temperature: 500 C Maximum Pressure: Varies according to ID* Typical Use: High-Pressure Plumbing *Request datasheet 3005D for more information. EDM-Cut Stainless Steel Tubing (10/PKG) CAP COLOR ID LENGTH PART NO. PRICE Red 0.005" 4cm cm cm cm cm Black 0.007" 5cm cm cm cm Blue 0.010" 5cm cm cm cm Green 0.020" 5cm cm cm cm Alltech Cut File Cut Abrasive Cut 0745 Alltech Pre-Cut Stainless Steel Tubing Kits Standard Tubing Kit 10 pieces 5cm 10 pieces 10cm (Available in all five inner diameters) Deluxe Tubing Kit 10 pieces 5cm x 0.010" 10 pieces 10cm x 0.010" 5 pieces 20cm x 0.010" 10 pieces 5cm x 0.020" 10 pieces 10cm x 0.020" 5 pieces 20cm x 0.020" 2 pieces 5cm x 0.030" 2 pieces 10cm x 0.030" 2 pieces 20cm x 0.030" Alltech Pre-Cut Stainless Steel Tubing Kits 6263 Deluxe Tubing Kit Standard 0.005" ID Kit Standard 0.007" ID Kit Standard 0.010" ID Kit Standard 0.020" ID Kit Standard 0.030" ID Kit

39 Tubing Cutters Alltech Rotary Tubing Cutter Cuts 1/32" to 1/8" OD Tubing Burr-Free Leaves Tubing ID Open Works with Metal and Glass- Lined Tubing TC-20 Tubing Cutter This CE-Marked tubing cutter produces smooth burr-free cuts on 1/4", 1/8" and 1/16" metal tubing. The dressing tool removes burrs and opens the ID of tubing as small as 0.007" Alltech Rotary Tubing Cutter DESCRIPTION QTY PART NO. PRICE For 1/32", 1/16", 1/8" Tubing Ea 3165 Replacement Cutting Wheels Parker Tubing Cutter An Inexpensive, Well-built Tool Cuts 1/8" to 1-1/8" OD Tubing Works with Metal Tubing TC-20 Tubing Cutter DESCRIPTION QTY PART NO. PRICE TC-20 Tubing Cutter* Voltage Selectable: / V, Ea Hz, CE-Certified Replacement Parts Cutting Wheels Dressing Tool, 1/16" Tubing Ea Needle Insert, 1/16" Dressing Tool Ea Dressing Tool, 1/8" Tubing Ea Needle Insert, 1/8" Dressing Tool Ea *Includes dressing tool for 1/16" tubing. Parker Tubing Cutter DESCRIPTION QTY PART NO. PRICE Parker Tubing Cutter Ea Replacement Cutting Wheels Alltech Clean-Cut Tubing Cutter Make Clean, Square Cuts without Deforming IDs Use with Teflon, Tefzel, Polyolefin, PEEK Razor Cutter with Replaceable Blade Notch for Precision Cutting Replaceable Cutting Blade Alltech Plier-Type Tubing Cutters Makes Clean Cuts on 1/16" OD Tubing Ideal for Cutting Tubing in Tight Places Aligning Holes Cuts Metal Tubing Alltech Clean-Cut Tubing Cutter Alltech Plier-Type Tubing Cutter DESCRIPTION QTY PART NO. PRICE Alltech Tubing Pliers for 1/16" OD Tubing Ea 3169 DESCRIPTION QTY PART NO. PRICE Clean-Cut Tubing Cutter Ea Replacement Blade Ea Plastic Tubing Cutter Ideal for PEEK, Tefzel and Other Plastic Tubing up to 1/8"OD Replaceable Blade Plastic Tubing Cutter 5376 DESCRIPTION QTY PART NO. PRICE Plastic Tubing Cutter Ea 3206 Replacement Blade Ea

40 Tubing Accessories Polyethylene Tubing Tags Secure, Easy-to-Install, Cable Tie Format Holds Bundles up to 3/4" Diameter Chemically Resistant Flex-Wrap Tubing Holds Parallel Tubing or Wiring Together Great for Gradient Pumps or Purging-Gas Lines 100% Teflon Chemically Inert Large Tags x 1.1" Small Tags x 0.375" 2356 Alltech Flex-Wrap Tubing 1/8"-1/2" 3/16"-1" 1/4"-2" PART NO. PRICE PART NO. PRICE Red Yellow Blue Orange Green Black White Polyethylene Tubing Tags DESCRIPTION QTY PART NO. PRICE Printed Tags A (lg. red) B (lg. yellow) Waste (sm. red) Detector (sm. white) Pump (sm. orange) Cable Turtles The Neat, Easy Way to Organize Messy Cables Patented Turtle Stores and Conceals Excess Cord Lengths Two Sizes Hold 1 to 2 Meters of Standard Electrical Cord Gas Tags Air (sm. green) Argon/Methane (sm. green) Helium (sm. green) Hydrogen (sm. red) Nitrogen (sm. green) Blank Tags Yellow (lg.) Orange (lg.) Sets A - D (lg.); Waste ; Detector, Ea Pump (sm.) Bulk Sets A - D (lg.) Cable Turtles Keep Extra Wires Out of Your Way! Clean up your work area with the patented Cable Turtle! The flexible rubber cups open to let you coil extra cables, cords, tubing, or wires. Fold the cups inward, and the Cable Turtle holds the coils securely in place - neat and out of sight. The small Cable Turtle will hold up to 1 meter of standard applicance cord, and nearly 3 meters of telephone wire. The large Cable Turtle holds up to 1 meter of thick instrument cord, 2 meters of standard appliance cord, or up to 6 meters of telephone wire. Use either size with cords carrying up to 1250W of power. Cable Turtles DESCRIPTION QTY PART NO. PRICE Small Red 5/pkg 5274 Blue 5/pkg 5276 Black 5/pkg 5278 Grey 5/pkg 5280 Large Red 4/pkg 5282 Blue 4/pkg 5284 Black 4/pkg 5286 Grey 4/pkg

41 Column Prefilters Alltech Column Prefilters Inexpensive Replaceable Filter Elements Protect your Column - Remove Particulates Before they Clog the Inlet Frit Preserve Efficiency with Direct Connection Alltech Metal-Free In-Line Filter Extend Column Life Inert and Biocompatible Replaceable Filter Element The Alltech Column Prefilter is placed between the injection valve and the column to remove particulate matter that might otherwise clog the column inlet frit. Particles in the mobile phase, sample, or from deteriorating valve seals will be trapped before they lodge in the column inlet. This eliminates the need to remove the column endfitting and risk damage to the packed bed or the column hardware. This In-Line filter is placed between the injection valve and column and consists of a reusable PEEK holder and inexpensive PAT (PEEK Alloyed with Teflon ) replacement filter elements. Only inert, high-strength polymers contact the fluid stream. Alltech Column Prefilters Material: 316 SS, Teflon, and Kel-F Max. Temperature: 100 C Max. Pressure: 5000psig Thread Type: UNF Plumbing: Direct Connect to Column Port or In-line via 1/16" OD Tubing Alltech Metal-Free Filters Material: PEEK Housing, PAT Filter Elements Max. Temperature: 100 C Max. Pressure: 5,000psig Thread Type: UNF Plumbing: 1/16" OD Tubing Direct-Connect Prefilter Kit Alltech Column Prefilters SofGrip Fitting Prefilter Housing 2µm Prefilter Distributor Disk In-Line Prefilter Kit Prefilter Housing Waters Female Valco Interchangeable Tips Connect to All Major Column Formats 0724 Column Prefilter Kits Direct-Connect Prefilter Kit In-Line Prefilter Kit Replacement Housing for Column Prefilters Direct-Connect Version In-Line Version Replacement Tips for Column Prefilters Female Fittings Waters Fittings Valco Fittings Replacement Distributor Disks, 5/pkg Replacement 2µm Filter Elements, 5/pkg µm Prefilter SofGrip Fitting In-line format accepts 1/16" tubing at both inlet and outlet for use when direct attachment to the column is not possible. Distributor Disk 0724A Alltech Metal-Free In-Line Filters DESCRIPTION QTY PART NO. PRICE Metal-Free In-Line Filters with 2µm Filter Element Ea Replacement 2µm Filter Elements

42 Column Prefilters High-Pressure In-line Column Prefilter 5560 Rheodyne Column In-Line Filter Protects Column Inlet Frit from Plugging Choice of Diameters to Match Column ID Replaceable 0.5 Micron Filter Elements This Column Prefilter introduces a minimum of unswept volume between the injector and column. All prefilter disks have a surface area of 7.1mm 2. High Pressure In-line Filters Material: 316 Stainless Steel Max. Temperature: 500 C Max. Pressure: 15,000psig Thread Type: 1/4-28 UNF for SSI ports UNF for CPI and Waters ports Plumbing: 1/16" OD Tubing 5420 High-Pressure In-Line Column Prefilter TUBING PREFILTER CONNECTION OD POROSITY PART NO. PRICE In-Line Column Prefilter SSI 1/16" 2µm SSI 1/16" 0.5µm Industry Standard CPI 1/16" 0.5µm Waters 1/16" 2µm Waters 1/16" 0.5µm Replacement Parts Filter Elements, 10/pkg 2µm Filter Elements, 10/pkg 0.5µm High-Capacity In-Line Filters The Rheodyne Model 7315 and 7335 Column In-Line Filters are connected between the injector and the column to protect the column from particulates generated from samples, mobile phases or instrument seals. The Model 7335 provides moderate dispersion and high capacity. Its 3mm diameter filter frit has the same capacity, yet provides much less dispersion than the older Model The Model 7315 provides low dispersion and moderate capacity. Its 1.5mm diameter filter frit has one-fourth the filtering capacity of the 3mm diameter filter, but its low dispersion allows it to be used with many microbore columns is recommended for conventional 4.6mm columns. The 7315 is recommended for 1 and 2mm. Both are supplied with two connecting tubes 6cm long, 0.007" ID. Three fittings and one filter element are supplied with each filter. Both designs are rated for use at up to 7,000psig. Flow Placed between the pump and the injector, these High-Pressure In-Line Filters provide a final polish to the mobile phase. All filter elements have a surface area of 2.5cm 2. High Capacity In-line Filters Material: 316 Stainless Steel Max. Temperature: 500 C Max. Pressure: 15,000psig Thread Type: 1/4-28 UNF for SSI ports UNF for CPI Plumbing: 1/16" OD Tubing High-Capacity In-Line Filters 5561 Rheodyne Column In-Line Filters Material: 316 Stainless Steel Max. Temperature: 500 C Max. Pressure: 7,000psig Thread Type: UNF Plumbing: 1/16" OD Tubing Rheodyne Column In-Line Filters DESCRIPTION POROSITY PART NO. PRICE Column In-Line Filters 1.5mm Filter Diameter 0.5µm 7315RV 3mm Filter Diameter 0.5µm 7335RV Replacement Parts 1.5mm Filter Element 0.5µm mm Filter Element 0.5µm FILTER CONNECTION POROSITY PART NO. PRICE High-Capacity In-Line Filters SSI 0.5µm SSI 2.0µm Industry Standard CPI 0.5µm Industry Standard CPI 2.0µm Replacement Parts Filter Elements, 2/pkg 0.5µm Filter Elements, 2/pkg 2.0µm

43 Mobile Phase Inlet Filters Last-Drop Filter/Sparger Filter and Sparger in One Convenient Unit Keeps Sparging-Gas Bubbles from Entering Pumping System Uni-Fit Adaptors Fit All Common Inlet Tubing The Alltech Last-Drop Filter/Sparger combines a mobile phase filter and sparger in one convenient device. A Teflon housing accepts both the pump inlet line and the sparging gas line via convenient PEEK slip-fit connections. The bottom of the housing contains the mobile-phase filter element of your choice. The filter element sits right on the bottom of the bottle, allowing the pump to draw all but the last few milliliters of solvent from the reservoir. The upper portion of the housing is fitted with two 10µm sparging elements which form two streams of finely dispersed bubbles for optimum degassing efficiency. The sparging elements direct the bubbles away from the pump inlet filter. Sparging-gas bubbles will never enter the pump causing loss of prime. The Uni-Fit adaptors accept all common Teflon pump inlet tubing (1.5, 2.2 and 3.0mm ID). Last-Drop Filter/Sparger Material: PEEK, Teflon Body SS or PAT Filters Porosity: 2µm or 10µm Max. Temperature: 100 C Plumbing: Slip Fit to 1.5-, 2.2-, or 3.0mm ID Tubing 10µm PAT Sparging Elements Teflon Housing Uni-Fit for Pump Inlet (Brown) Uni-Fit for Sparging Gas (Black) Last-Drop and Mini Last-Drop Mobile Phase Inlet Filters Flat-Bottom Design Draws All the Solvent from the Reservoir High Surface Area for Long Life Teflon Housing with Stainless Steel, Biocompatible PAT or Teflon Filter The Alltech Last-Drop Mobile Phase Inlet Filter uses a flat filter element that sits on the bottom of the bottle, allowing the pump to draw all but a few milliliters of mobile phase from the reservoir without introducing air into the system. You get more analyses from each batch of mobile phase and minimize hazardous waste by using the full capacity of your mobile phase reservoirs. Each Last-Drop Mobile Phase Inlet Filter is supplied with either PEEK fittings to attach directly to any 1/8" OD tubing, or with Uni- Fit adaptors that slip-fit into 1.5, 2.2 or 3.0mm ID tubing. Last- Drop is available in two sizes: the original 0.900" (22mm) diameter design and the new Mini Last-Drop with a 0.800" (20mm) diameter. The Mini Last-Drop fits standard 1L and 4L solvent bottles from Wheaton, Schott, and other manufacturers. Last-Drop Inlet Filter Material: Teflon Body SS, Teflon, or PAT Filter Porosity: 2µm, 5µm, or 10µm Max. Temperature: 100 C Plumbing: Teflon Housing 1/8" OD Tubing (with Fitting) or Slip Fit to 1.5-, 2.2-, or 3.0mm ID Tubing (with Adaptor) Uni-Fit Adaptor Slip fits to 1.5, 2.2, or 3.0mm ID Tubing 1/4-28 Fitting Attaches to 1/8" OD Tubing Stainless Steel or PAT Mobile Phase Filter SS, Teflon or PAT Filter Last-Drop Filter/Spargers 2µm SS Filter/Sparger µm SS Filter/Sparger µm PAT Filter/Sparger µm PAT Filter/Sparger Last-Drop Inlet Filters PART NO. PART NO. DESCRIPTION W/FITTINGS W/UNI-FIT PRICE Last-Drop Inlet Filter 0.900" (22mm) Diameter 2µm SS Filter µm SS Filter µm PAT Filter µm PAT Filter µm PAT Filter µm Teflon Filter Mini Last-Drop Inlet Filter 0.800" (20mm) Diameter 2µm SS Filter µm SS Filter µm PAT Filter µm PAT Filter µm PAT Filter µm Teflon Filter

44 Mobile Phase Inlet Filters Last-Drop Cup-Style Mobile Phase Inlet Filters Uses All the Mobile Phase in the Reservoir High Surface Area for Long Filter Life Disposable Filters and Reusable Teflon Sleeve for Low Cost Last-Drop Cup Filters use all the mobile phase in the reservoir without drawing air into the system. A stainless steel filter cup provides the same high surface area of conventional mobile phase filters. But unlike conventional filters, a Teflon sleeve fits over the cup filter so mobile phase is drawn from the bottom of the bottle. The low-cost filter cup is easy to replace when clogged. Just slide the clogged filter out of the sleeve and slide a new filter in its place. The heavy Teflon sleeve acts as a sinker so the filter stays at the bottom of the reservoir. A Uni-Fit connector attaches the Last-Drop Cup-Style filter to 1.5, 2.2 or 3.0mm ID pump inlet tubing without fittings. Last-Drop Cup-Style Inlet Filters Material: PEEK, Teflon, SS Porosity: 2µm or 10µm Max. Temperature: 100 C Plumbing: Slip Fit to 1.5-, 2.2-, or 3.0mm ID Tubing Last-Drop Economy Mobile Phase Inlet Filters Flat Bottom Design Draws All Solvent from the Reservoir Economical Style Means Economical Price Teflon and Stainless Steel Construction Tapered Port Accepts 1/8 OD Tubing Now the last-drop conveniences are made even more economical! Alltech Last-Drop Economy Filters have a stainless steel filter that sits on the bottom of the mobile phase reservoir drawing in all but a few milliliters of mobile phase. The Teflon housing is highly inert and has a 1/8 tapered port where 1/8 OD Teflon tubing is pushed securely into place. Last-Drop Economy Inlet Filters Material: Teflon, SS Porosity: 2µm or 10µm Max. Temperature: 100 C Plumbing: 1/8" OD Tubing Uni-Fit Connector Slip fits to 1.5, 2.2, or 3.0mm ID Tubing 6265 Reuseable Teflon Sleeve Replaceable Stainless Steel Cup Filter 6337 Last-Drop Cup-Style Inlet Filters PART NO. DESCRIPTION W/UNI-FIT PRICE Last-Drop Cup-Style Inlet Filter With 2µm SS Cup Filter With 10µm SS Cup Filter Replacement 2µm SS Cup Filter Replacement 10µm SS Cup Filter Choosing a Mobile phase Inlet Filter Filter Materials 316 Stainless Steel: For most standard applications, a standard stainless steel filter is suitable. Hastalloy C: A slightly more inert grade of stainless steel; suitable for use in halogenated solvents where halide salts tend to corrode other types of stainless steel. Polyethylene: Good general inertness. Used mainly for metal-free IC or biochromatography applications. Titanium: For IC or biochromatography; this non-ferrous filter does not leach ions into the solvent stream. Last Drop Economy Inlet Filters DESRIPTION POROSITY PART NO. PRICE Stainless Steel, 22mm 2µm Stainless Steel, 22mm 10µm CPI Stainless Steel Mobile Phase Inlet Filter 316 Stainless Steel Filter 10µm Porosity Knurled Stainless Steel Holder Connects Finger-Tight to 1/8" OD Tubing Stainless Steel Body Material CPI Stainless Steel Inlet Filter Material: SS Porosity: 10µm Max. Temperature: 500 C Plumbing: 1/8" OD Tubing 6297 Filter Porosities 10µm porosity provides good, general-purpose filtering. Smaller porosity grades (such as 2µm) filter more effectively, but tend to resist flow as the pump tries to draw more solvent (>5mL/min) in. >10µ should be reserved for preparative flows 20 to 100mL/min. CPI Stainless Steel Inlet Filters DESCRIPTION POROSITY QTY PART NO. PRICE Filter Assembly 10µm Ea Repl. Filter Elements 10µm Repl. Tefzel Ferrules

45 Mobile Phase Inlet Filters 1/4-28 Threaded Mobile Phase Inlet Filter Slip-On SS Mobile Phase Inlet Filter 1/4-28 Flat-Bottom Port Allows Easy Connection to Flange-Free Fittings Stainless Steel or Titanium Filters 316 Stainless Steel Filters 2µm or 10µm Porosity Economical Mobile Phase Inlet Filtration 10µm or 40µm Porosity /4-28 Threaded Inlet Filters Slip-On SS Inlet Filters Material: PEEK Body, SS or Titanium Filters Material: 316 Stainless Steel Porosity: 10µm or 40µm Porosity: 2µm or 10µm Max. Temperature: 100 C Max. Temperature: 500 C Plumbing: 1/16" or 1/8" OD Tubing Plumbing: Slip Fit to 1.5, 2.2, or 3.0mm ID Tubing 1/4-28 Threaded Inlet Filters Slip-On SS Inlet Filters DESCRIPTION POROSITY QTY PART NO. PRICE Stainless Steel 10µm Ea µm Ea Titanium 10µm Ea µm Ea Tapered Port Mobile Phase Inlet Filter Tapered Internal Port Pushes Directly onto 1/8" OD Tubing Stainless Steel or Titanium Filters PEEK Body Material 6298 DESCRIPTION POROSITY QTY PART NO. PRICE For 0.062" (1.5mm) ID 2µm Ea For 0.062" (1.5mm) ID 2µm For 0.062" (1.5mm) ID 10µm Ea For 0.062" (1.5mm) ID 10µm For 0.085" (2.2mm) ID 2µm Ea For 0.085" (2.2mm) ID 2µm For 0.085" (2.2mm) ID 10µm Ea For 0.085" (2.2mm) ID 10µm For 0.125" (3.0mm) ID 2µm Ea For 0.125" (3.0mm) ID 2µm For 0.125" (3.0mm) ID 10µm Ea For 0.125" (3.0mm) ID 10µm Tapered Port Mobile Phase Inlet Filters Material: PEEK Body, SS or Titanium Filters Porosity: 10µm or 40µm Max. Temperature: 100 C Plumbing: 1/8" OD Teflon Tubing Tapered Port Mobile Phase Inlet Filters Metal-Free Mobile Phase Inlet Filter Replaceable Polyethylene Filter Elements 20µm Porosity Metal-Free for IC or Biochromatography Applications Threaded Body Allows Easy Connection to 1/4-28 Fittings DESCRIPTION POROSITY QTY PART NO. PRICE Stainless Steel 10µm Ea µm Ea Titanium 10µm Ea µm Ea Metal-Free Inlet Filters Material: PEEK Body, Polyethylene Filter Hastalloy C Mobile Phase Inlet Filter Hastalloy C is ideal with Halogenated Solvents 2µm Porosity Hastalloy C Inlet Filters 5216 Porosity: 20µm Max. Temperature: 100 C Thread Type: 1/4-28 UNF Plumbing: 1/16" or 1/8" OD Tubing Metal-Free Inlet Filters DESCRIPTION POROSITY QTY PART NO. PRICE Material: Hastalloy C Porosity: 2µm Max. Temperature: 500 C for 1/8" OD 20µm Ea for 1/16" OD 20µm Ea Replacement Filter Elements 20µm Plumbing: Slip fit to 1.5 or 3.0mm ID Tubing Hastalloy C Inlet Filters DESCRIPTION POROSITY QTY PART NO. PRICE for 0.062" (1.5mm) ID 2µm Ea 9400 for 0.125" (3.0mm) ID 2µm Ea

46 Mobile Phase Delivery/Storage-Bottle Kits Kontes Ultra-Ware Three-Valve Bottle Kit Color-Coded Helium Tight Valves Conical Bottom Safety Coated Reservoir Available in THF-Resistant Version The Ultra-Ware Three-Valve Bottle Kit features three color-coded, helium-tight valves to maintain a sealed environment between runs. This system comes complete with a Three Valve Cap, a Conical Bottom Ultra-Ware Reservoir, and the required 1/4-28 fittings and tubing. Kontes Ultra-Ware Three-Valve Bottle Kit Standard Three-Valve Bottle Kit With 1 Liter Reservoir (GL-45) With 2 Liter Reservoir (GL-45) With 5 Liter Reservoir (GL-45) THF-Resistant Three-Valve Bottle Kit With 1 Liter Reservoir (GL-45) With 2 Liter Reservoir (GL-45) With 5 Liter Reservoir (GL-45) Three-Valve Bottle Kit 1842 Alltech Biocompatible Bottle Kits Improve Pump Performance by Pressurizing Solvent Bottle Eliminate Wasted Helium During Sparging Prevent Breakage with Thick Walled Plastic or Safety Coated Glass Bottles Biocompatible Bottle Kits are available with heavy walled highdensity polyethylene (HDPE) or safety coated glass bottles. HDPE bottle kits can be pressurized to 15psig while the glass bottle kits can be 5596 Bottle Kits include one bottle with purge vent valve cap, storage cap, tubing and 3 titanium spargers. pressurized to 8psig. The bottle kit s cap system consists of a threaded outer cap and a cap insert. A purge/vent valve, gas inlet tubing, and solvent outlet tubing are part of the cap insert. Opening the purge/vent valve allows the bottles to be purged. While closing the valve allows the bottles to be pressurized. Sparging gas consumption is minimized, as continual sparging is not required. Simply sparge the solvent for 5 minutes at the beginning of the day and close the bottle s purge/vent valve to pressurize the reservoir. After that, the only sparging gas used is that which is required to displace consumed solvent. Kontes Ultra-Ware Three-Hole Bottle Kit Safety-Coated Conical Bottom Reservoirs Excellent Chemical Resistance The standard Three-Hole Bottle Kit includes the patented conical-bottom Ultra-Ware reservoir and a Standard Three-Hole Cap with 1/4-28 threads on both the top and bottom portions of the cap for separate tubing lines inside and outside the reservoir. Kontes Ultra-Ware Three-Hole Bottle Kit Three-Hole Cap System With 1 Liter Reservoir (GL-45) With 2 Liter Reservoir (GL-45) With 5 Liter Reservoir (GL-45) Kontes Ultra-Ware Three-Hole Economy Bottle Kit Sparge and Deliver Mobile Phase Economically Three-Hole Bottle Kit The Economy Three-Hole Bottle Kit includes a flat-bottom Ultra-Ware reservoir and an Economy Three-Hole Cap with 1/4-28 threads on the top portion of the cap. Pass a single length of tubing through the cap into the reservoir. Two of the ports have 1/8" through-holes for mobile phase delivery and helium sparging. The third 1841 port has a 1/16" through-hole used for Three-Hole either a vent or recycling return line. Economy Bottle Kit 2226 Biocompatible Mobile Phase Handling System HDPE Bottle Kits (15psig) 1L (GL-53 Threads) L (GL-53 Threads) L (GL-83 Threads) Safety Coated Glass Bottle Kits (8psig) 1L (GL-45 Threads) L (GL-45 Threads) Replacement Bottles* 1L (GL-53 Threads) HDPE Bottle L (GL-53 Threads) HDPE Bottle L (GL-83 Threads) HDPE Bottle L (GL-45 Threads) Glass Bottle L (GL-45 Threads) Glass Bottle Replacement Cap Inserts for 1 or 2L HDPE Bottle for 4L HDPE Bottle for 1 or 2L Glass Bottle Replacement Outer Caps for 1 or 2L HDPE Bottle (GL-53 Threads) for 4L HDPE Bottle (GL-83 Threads) for 1 or 2L Glass Bottle (GL-45 Threads) *Comes with storage cap. Kontes Ultra-Ware Three-Hole Economy Bottle Kit Economy Three-Hole Bottle Kit* With 1 Liter Flat Bottom Reservoir With 2 Liter Flat Bottom Reservoir With 5 Liter Flat Bottom Reservoir With 10 Liter Flat Bottom Reservoir With 20 Liter Flat Bottom Reservoir *GL-45 threads. 497

47 Mobile Phase Delivery/Storage - Bottles Alltech Biocompatible HDPE Bottles Thick Walled HDPE Bottles will not Break Ideal for Ion Chromatography Inexpensive Alltech biocompatible bottles are made from heavy walled high-density polyethylene (HDPE), and can be pressurized to 15 psig with the appropriate delivery cap (see page 497 for bottle kits). These plastic bottles are ideal for IC applications, or any which use an aqueous buffer solution. HDPE bottles come with a storage cap, are extremely durable, and 6333 won t break if the bottle is accidentally dropped. Alltech Biocompatible HDPE Bottles Alltech Safety-Coated Glass Bottles Economical Flat-Bottom Design External Coating Prevents Scattering Glass if Breakage Occurs Alltech Safety-Coated Glass Bottles are ideal for use with any HPLC mobile phase solvent. These thick-walled glass bottles have an external coating which prevents the glass from scattering if accidental breakage occurs. Alltech Safety-Coated Glass Bottles have a flat bottom, and can be pressurized to 8psig when the appropriate cap is used (see page 497 for bottle kits). All bottles come complete with storage cap. Alltech Safety-Coated Glass Bottles 6332 DESCRIPTION THREAD SIZE PART NO. PRICE HDPE Bottles with Storage Cap 1L Bottle GL L HDPE Bottle GL L HDPE Bottle GL DESCRIPTION THREAD SIZE PART NO. PRICE Safety Coated Glass Bottles* with Storage Cap 1L Glass Bottle GL L Glass Bottle GL Kontes Ultra-Ware Safety Coated Glass Bottles Plastic Coating Retains Glass Fragments in case of an Accident and Blocks UV Light Safety Pressure Rating of 6psig Conical Bottom Reservoirs Delivers All Mobile Phase Each Ultra-Ware reservoir is manufactured from the most chemically inert glass available to prevent the leaching of any extractables into the mobile phase solvent. In case of an accident, the external safety coating helps retain glass fragments and serves as a UV blocking agent for all UV light up to 385 nm. Ultra-Ware reservoirs are available with a conical or flat bottom. The conical bottom delivers virtually all mobile phase solvent without dangerous reservoir tilting. Glass Mobile Phase Bottles Economical Graduated Markings Borosilicate Glass Teflon -Lined Cap Economical glass mobile phase bottles with Teflon -lined screw caps are available in 500mL, 1000mL, and 2000mL sizes. These graduated borosilicate glass bottles can be ordered individually or by the case Conical Bottom 5574 Kontes Safety-Coated Bottles Flat Bottom DESCRIPTION THREAD SIZE PART NO. PRICE Ultra-Ware Conical Bottom Reservoir 1L GL L GL L GL Glass Mobile Phase Bottle 500ML 1000ML 2000ML Height: 7.5" 9" 10.5" (190mm) (229mm) (265mm) Diameter: 3.5" 4" 5.3" (89mm) (102mm) (135mm) Coating: None None None Glass Mobile Phase Bottles VOLUME THREAD SIZE QTY PART NUMBER PRICE 500mL mL mL mL mL GL mL GL mL GL mL GL Ultra-Ware Flat-Bottom Reservoir 1L GL L GL L GL As with any vacuum or pressure application, glassware cannot be guaranteed against breakage due to varying conditions of field useage. 498

48 Mobile Phase Delivery/Storage - Caps Alltech Safety Caps with Purge/Vent Valve Purge/Vent Valve Easily Opens and Closes to Accommodate Helium Sparging Two Through-holes for Simple Tubing Insertion The safety cap consists of a threaded outer cap and a cap insert. A purge/vent valve, gas inlet hole, and solvent outlet hole are part of the cap insert. Opening the purge/vent valve allows the bottles to be purged. While closing the valve allows the bottles to be pressurized. Alltech Safety Caps with Purge/Vent Caps Cap Insert for GL-45 Outer Cap for GL-53 Outer Cap for GL-85 Outer Cap Outer Caps GL-45 Threads GL-53 Threads GL-83 Threads Kontes Mobile Phase Delivery Caps 2-Hole Safety Cap with Purge Vent Valve Sparge and Deliver Mobile Phase without Switching Caps Available with or without Helium-Tight Valves Alltech Economy Mobile Phase Caps Alltech offers the most economical way to helium sparge* and deliver HPLC mobile phases. The MP1-Cap has an insert made from PTFE, a propylene O-ring and a polypropylene screw collar. The insert contains three 1/4-28 threaded ports with through-holes (2x1/8 and 1x1/16 ) that allow the tubing to either be pushed through or connected with flanged fittings. The MP2-Cap is made from Tefzel and polypropylene and has three unthreaded holes for tubing insertion (2x1/8 and 1x1/16 ). Just push the tubing through! Alltech also offers Teflon lined screw caps with 1 or 2 predrilled holes. *Suitable for continuous helium sparging. Not intended for build-up of helium environment. Alltech Economy Mobile Phase Caps DESCRIPTION QTY THREAD SIZE PART NO. PRICE MP1-Cap Ea GL MP2-Cap Ea GL Hole Screw Cap 4/pkg Hole Screw Cap 4/pkg Omnifit Mobile Phase Delivery Caps Three-Hole Cap Three-Valve Cap Kontes mobile phase delivery caps connect onto any GL-45 threaded reservoir, and are available with or without valves. The Three-Valve Cap features three color-coded, helium-tight valves to maintain a sealed environment between runs. Tubing is connected using 1/4-28 fittings. The Standard Three-Hole Cap has 1/4-28 threads on the top and bottom portions of the cap for separate tubing lines inside and outside the reservoir. The Economy Three-Hole Cap has 1/4-28 threads on the top portion of the cap. Pass a single length of tubing through the cap into the reservoir. Two ports have 1/8 through-holes, while the third port has 1/16 through-hole used for either a vent or recycling return line. Anti-twist Design Prevents Tubing from Getting Twisted or Tangled Highly inert Teflon and Polypropylene Construction Stainless Steel inserts prevent Cross- Threading Omnifit bottle caps are made from a single PTFE block built into a Polypropylene threaded cap. The anti-twist design enables the central block to turn independently when the cap is being connected onto the bottle. This prevents tubing from being twisted and tangled. The 1/4-28 ports have non-wetted stainless steel threaded inserts to ensure an accurate, reliable connection time and time again. Omnifit caps are available with or without Kel-F turn-key valves which provides a completely closed system whenever necessary Kontes Mobile Phase Delivery Caps DESCRIPTION THREAD SIZE PART NO. PRICE 3-Valve Cap GL Economy 3-Hole Cap GL Standard 3-Hole Cap GL TFE-Storage Cap GL Omnifit Mobile Phase Delivery Caps DESCRIPTION THREAD SIZE PART NO. PRICE 2-Hole Cap GL Hole Cap GL Hole Cap with Valve GL Hole Cap with Valve GL

49 Mobile Phase Filtration Vacuum Filtration System Interchangeable Funnel and In-Line Systems Filter Funnel In-Line Filter Cap Eliminate Transfer Steps with Direct Filtration into GL-45 Reservoir Interchangeable Funnels and In-Line Filter Cap Handle Any Filtration Volume Unbreakable, Solvent Resistant, Inert Polypropylene Construction Stable and Leak-Proof Threaded Connections Mesh Filter Support Increases Filtration Flow Rates Alltech s new vacuum filtration products simplify and improve high-volume filtration. Our filter funnels and in-line filter cap save you time and money. And because they re made from inert, durable polymers, you ll never hear the sound of breaking filtration glassware again! Base Base Vacuum Filter Funnel 4391 In-Line Vacuum Unit 4385 Vacuum Filter Funnels For 100mL - 2L Filtration Tasks Alltech s Vacuum Filter Funnel is the inert, durable, cost-effective alternative to glass or disposable units. The unbreakable, leakproof construction accommodates any 47mm diameter membrane. A threaded filter base connects directly to any receiver with GL45 threads, eliminating cumbersome clamps, side-arm flasks or extra transfer steps. Connect the filter base directly to your vacuum source using one of the six vacuum tubing adaptors included with each unit. The highly solvent resistant, low-extractable, polypropylene construction is ideal for mobile-phase filtration, degassing, and culture media filtration. Choose from 1L and 2L funnel volumes. In-Line Vacuum Filter For 100mL - Multi-Liter Filtration Tasks If you have a high-volume filtration job, or require a system that limits filtrate atmospheric exposure, use Alltech s In-Line Filtration System. The In-Line System uses the Filter Funnel s stable, leak-proof filter base, but replaces the funnel with an In- Line Filter Cap. Tubing connected to the In-Line Filter Cap draws liquids into the system from any container. Liquids are never poured from their original containers into a funnel, so atmospheric exposure and handling hazards are limited. The In- Line Filter Cap s solvent resistant, low-extractable, polypropylene fluid path accepts any standard 47mm membrane. This is the only In-Line Filtration System that easily restores flow when an air pocket accumulates above the filter membrane. Unlike other systems that require disassembly and membrane replacement when lock-up occurs, Alltech s exclusive (patent pending) built-in priming valve restores flow in seconds without compromising the flow path or changing the membrane. i See page 502 for Benchtop Vacuum Station. In-Line Filtration System with Benchtop Vacuum Station Vacuum Filtration Systems DESCRIPTION QTY PART NO. PRICE 1L Filter Funnel System Includes: Base, Adaptor Kit, Mesh Filter Support, 1L Funnel 2L Filter Funnel System Includes: Base, Adaptor Kit, Mesh Filter Support, 2L Funnel In-Line Filtration System Includes: Base, Adaptor Kit, Mesh Filter Support, In-Line Filter Cap Replacement Parts 1L Funnel In-Line Filter Cap Hose Barb Adaptor Kit Polypropylene Mesh Filter Support Ring Stainless Steel Mesh Filter Support Ring As with any vacuum or pressure application, glassware cannot be guaranteed against breakage due to varying conditions of field useage. Accessories 1L GL-45 Safety-Coated Glass Bottle L GL-45 Safety-Coated Glass Bottle

50 Mobile Phase Filtration Kontes Ultra-Ware Filtration Cap System Filter, Degas, and Deliver Mobile Phase from the Same Reservoir Conical Bottom Safety-Coated Reservoir This modular system provides easy, fast, and efficient mobile phase preparation. The Filtration/Degassing Cap filters through 47mm diameter filter membranes directly into the reservoir. Vacuum degassing is accomplished by closing the Hi-Vac valve on the Solvent Pickup Adaptor. This system comes complete with the Filtration/Degassing Cap, a standard Solvent Pickup Adaptor, a Conical Bottom Ultra-Ware Reservoir, and the required fittings and tubing Alltech Solvent Filtration Apparatus The Alltech Solvent Filtration Apparatus rapidly filters and degasses HPLC and IC mobile phases. Since the presence of extraneous material can seriously damage costly components, proper filtration of samples and solvents is a critical step in the HPLC process. Depending on your analytical requirements, several interchangeable funnel and flask options are available. The Solvent Pickup Adaptor is an improvement on the current filtration systems. It draws the solvent directly from a reagent bottle through a 47mm filter and into the collecting flask. You can easily convert to the newer style by replacing the funnel with the solvent pickup adaptor Conical Bottom Reservoir Solvent Pick-Up Adaptor Filtration/ Degassing Cap Solvent Filtration Apparatus Glass Funnel Clamp Solvent Pickup Adaptor A 0860 B 2765 C 0861 Filter of Choice CTFE Adaptor Vacuum Adaptor Support Frit Fritted Glass Support Base Solvent Bottle D 0866 E 0867 F mL/1L 2L 2771 Kontes Ultra-Ware Filtration Systems Alltech Solvent Filtration Apparatus GRAPHIC Filtration Cap System With 1 Liter Reservoir With 2 Liter Reservoir With 5 Liter Reservoir Replacement Parts and Accessories Ultra-Ware Conical Bottom Reservoir* A 1 Liter A 2 Liter A 5 Liter Adaptors and Caps B Solvent Pick-Up Adaptor (THF Resistant) C Filtration/Degassing Cap D CTFE, 1/4-28 to 1/8" Barb Adaptor D CTFE, 1/4-28 to 5/32" Barb Adaptor E Vacuum Adaptor 1/4-28 to 1/4" ID Tubing F Replacement Support Frit *Bottles have 45mm threads. Solvent Filtration Apparatus 125mL Flask, 15mL Funnel, 25mm Filter Support, mm Clamp, 0.2µ Nylon Filters 100/pkg 1L Flask, 300mL Funnel, 47mm Filter Support, mm Clamp, 0.2µ Nylon Filters 100/pkg 2L Flask, 500mL Funnel, 47mm Filter Support, mm Clamp, 0.2µ Nylon Filters 100/pkg Replacement Parts and Accessories 125mL Flask (For 2331) L Flask (For 2001) L Flask (For 2003) mL Glass Funnel (For 2331) mL Glass Funnel (For 2001) mL Glass Funnel (For 2003) L Glass Funnel (for 2003) mm Fritted Base Support (For 2331) mm Fritted Base Support (For 2001) mm Fritted Base Support (For 2003) mm Aluminum Clamp (For 2331) mm Aluminum Clamp (For 2001, 2003) mm Solvent Pick Up Adaptor mm Nylon Filter Membranes, 0.2µ, 100/pkg 2034 (For 2001, 2003) 25mm Nylon Filter Membranes, 0.2µ, 100/pkg 2050 (For 2331) 501

51 Mobile Phase Filtration Pumps and Degassers Benchtop Vacuum Station Pulls Vacuum to 28.5" Hg Maintenance-Free Portable Continuous LCD Display of Vacuum Level Perfect Companion for Alltech Vaccum Filtration Systems Helium Sparging Manifold Kit Deliver Sparging Gas to 4 Reservoirs Easy Control of Sparge Rate Includes Pressure Relief Valve as Safety Feature Alltech's Benchop Vacuum Station is a versatile, powerful, userfriendly answer to most vacuum applications. Three modes of operation offer flexibility for different applications. Continuous Vacuum Mode pulls a maximum vacuum with a minute timer. Continuous Vent Mode clears the pump heads of vapors. Set Point Mode allows you to select the vacuum level, and it maintains that vacuum level with an Absolute Vacuum Sensor, making runs reproducible regardless of altitude or barometric conditions. It is the perfect pump for filtration and solid phase extraction tasks. The Alltech Manifold Kit is used to distribute sparging gas to as many as 4 solvent reservoirs. This gas distribution manifold uses one-way check valves to prevent back flow to the manifold from pressurized bottles. The manifold has an on/off toggle switch and a knob to control the sparging rate. As a safety feature, manifold kits come with a pop-off valve set at 15psig or 8psig. The manifold kit with the pop-off valve set at 8psig is for use with safety coated glass bottle kits, and that set at 15psig is for HDPE bottle kits. Each manifold kit comes with a 5psig pressure regulator and all the necessary fittings and tubing required for connection to your sparging gas supply. Benchtop Vacuum Station Specifications Maximum Pull: 725mm Hg (28.5") Flowrate: 13L/min Timer: minutes Dimensions: 8.7" W x 9.5" D x 4.5" H (22cm W x 24.2cm D x 11.5cm H) Helium Sparging Manifold Specifications Pressure Regulation: Up to 5psig Pressure Relief Set: 15psig for HDPE 8psig for Safety Coated Glass Dimensions: 5.4"W x 6.3"D x 27"H (13.7cm W x 16.0cm D x 6.8cm H) Benchtop Vacuum Station Helium Sparging Manifold Kits 115V V 6419 Vacuum Station Accessories DESCRIPTION QTY PART NO. PRICE Tygon Tubing 1/8" ID, 3/8" OD 50 Ft /16" ID, 9/16" OD 10 Ft /4" ID, 3/4" OD 10Ft 6469 Manifold Kit with 15psig Safety Valve* Manifold Kit with 8psig Safety Valve *Typical pressure rating for HDPE bottles. Typical pressure rating for safety coated glass bottles. i For more information on Bottle Kits, refer to page

52 Mobile Phase Degassing Sparging Relief Kit Prevents Damage to Gas Line Components Prevents Cross Contamination of Mobile Phase Reservoirs Foolproof, Patented Design* Protect gas line components and prevent cross-contamination of mobile phase reservoirs with Alltech s Sparging Relief Kit. When the helium gas supply is turned off, the mobile phase often backs up into the sparging line, contaminating adjacent mobile phase reservoirs and/or damaging sensitive gas regulators and needle valves. The Alltech Sparging Relief Kit puts an end to these problems through a pressure equalization device and anti-backflow check valve. The pressure equalization device consists of a union installed on the sparge line inside the mobile phase reservoir above the fluid level, preventing liquid from siphoning into the sparge line. A second level of protection is afforded by installing the Anti- Backflow Check Valve on the sparge line outside the mobile phase reservoir. The Alltech Sparging Relief Kit is supplied complete with Flange-Free fittings for easy installation on any 1/8" sparging line. *U.S. Patent #4,690,437 Installation of Sparging Relief Kit Helium Sparger Threaded Cap Available in Single, Binary or Ternary Versions The Alltech Helium Sparger contains a 316 stainless steel sparging element which may be immersed in the mobile phase reservoir. A length of 1/8" Teflon tubing connects the sparger to a flow-control valve (optional) which is connected to a source of helium. The flow control valve allows the bubble rate to be adjusted. A 38mm, two-hole cap attaches to the top of standard 1-liter mobile phase reservoirs or to any 4-liter solvent bottle. The Alltech Helium Sparger is available in single, binary and ternary versions. All Helium Sparger Kits include tubing, reservoir cap(s), and sparging element(s). For kits with a flow control valve, one valve controls the bubble rate on all sparging outlets. Helium Spargers Flow Control Valve Cap Sparger ;;; ;;;; ;;; ; Teflon Tubing 0881 Sparge Line Solvent Line Anti-Backflow Check Valve Single Sparger with Flow Control Valve without Flow Control Valve Binary Sparger with Flow Control Valve without Flow Control Valve Ternary Sparger with Flow Control Valve without Flow Control Valve Replacement Sparging Element Pressure Equalization Union Ultrasonic Bath Sparging Relief Kit Sparging Relief Kit Includes: Pressure Equalization Union, Anti-Backflow Check Valve and All Fittings 0879 For Laboratory Cleaning, Solvent Degassing, and Dispersing Slurries 2.8 Liter Tank Mechanical Timer Overall Size: 11.6" L x 13.3" W x 12" H Tank Size: 9.5" L x 5.5" W x 4.0" H Ultrasonic Bath 5602 Replacement Parts Pressure Equalization Union Anti-Backflow Check Valve V V V 503

53 Mobile Phase Degassing New Alltech On-Line Degassing System Highest Efficiency Degassing System Available Fastest Equilibration Times Zero Baseline Fluctuation Error and Leak Checking Functions Low Operating Noise High degassing efficiency, fast equilibration times, zero baseline fluctuation, error and leak checking functions, and low operating noise make Alltech's re-designed On-Line Degassing System the best money can buy. A new, more efficient membrane design constructed of highly gas permeable Teflon AF, a continuous run vacuum pump designed specifically for degassing applications, and NO-OX tubing to keep atmospheric gases from re-entering degassed mobile phase are the key components to the On-Line Degassing System's success. Alltech's degassing membranes, constructed of Teflon AF, outperform the Teflon PTFE membranes used in other degassing systems. The high degassing efficiency of Teflon AF allows the membrane volume to be reduced to approximately 400µL or about 2 orders of magnitude less than membranes constructed of Teflon PTFE. Low membrane volume results in very quick solvent changeover and equilibration times. The shorter flow path also reduces the flow resistance in front of the pump reducing pump cavitation and outgassing. Teflon AF membranes are low in extractables and are very inert, so the Degassing System can be used with most solvents including THF and Methylene Chloride. The Alltech On-Line Degassing System's vacuum pump has been designed specifically for LC mobile phase degassing. It operates continuously, so the system is always evacuated to the maximum attainable vacuum level. Detector baselines are stable as fluctuations due to vacuum level hysteresis common to other degassing systems don't exist. The vacuum pump operates at two speeds. Upon start-up, the pump operates at high speed to quickly pull the vacuum down to an optimum level for degassing. Once the optimum vacuum level is reached, the pump switches to a slow speed, running virtually silent while maintaining a constant vacuum. Running at a low speed reduces wear and tear on the vacuum pump, increasing the instrument's lifetime. Alltech's exclusive NO-OX tubing adds even more value to the On-Line Degassing System by keeping solvent degassed. NO-OX is double-layer tubing consisting of an inert Teflon inner layer and a gas impermeable outer layer. The tubing is used to transport mobile phase from the On-Line Degassing System to your HPLC pump and keep gases out. Transport tubing supplied with other degassing systems lets gases reenter the mobile phase, significantly reducing performance. Error and leak checking, a universal power supply, and a compact design are additional features that make the Alltech On-Line Degassing System superior to competitors' units. Upon start-up, the Degassing System goes through a series of checks to make sure the unit is functioning properly. After the vacuum pump begins, the vacuum level is monitored to detect the presence of a leak or a problem with the vacuum pump. Colored LED's alert the user of any errors. The system incorporates a universal power supply that allows it to operate from any AC line voltage between 85 and 264 VAC, at 50 or 60 Hz. Finally, the Degassing System's compact size (2.9"W x 5.5"Hx 10.8"D) makes it the smallest membrane degassing system available. The On-Line Degassing System degasses up to four solvents at one time. All of the necessary tubing (including NO-OX tubing) and fittings needed to install the system are supplied along with a complete instruction manual and documentation of CE certification. Alltech On-Line Degassing System Specifications Number of Channels: 4 Internal Channel Volume: 400µL Wetted Parts: PEEK, and Teflon AF Dimensions: 2.9" W x 5.5" H x 10.8" D (7.3cm W x 14.0cm H a 27.3cm D) Power: VAC, 50 or 60 Hz Display: Green and yellow LED's Warranty: 4 year Alltech On-Line Degassing System On-Line Degassing System (4-Channel) On-Line Degassing System Replacement Parts NO-OX Tubing 1/8" OD x 1.5mm ID (10ft) /8" OD x 1.5mm ID (50ft) NO-OX Fittings NO-OX Fitting Kit (10 Nuts, 10 Ferrules, 10 Inserts) Replacement PEEK 1/4-28 Nuts, 5pkg Replacement Tefzel 1/8" Ferrules, 10/pkg Replacement CTFE Inserts, 10/pkg

54 Mobile Phase Degassing Alltech NO-OX Tubing and Fittings Eliminates Regassing Without Sacrificing Inertness Easy to Install and Use Flexible, Convenient, Versatile Alltech NO-OX Tubing prevents mobile phase regassing on any LC system, no matter what degassing method you use (see Figure 1). NO-OX Tubing is 1/8" OD x 1.5mm ID and is available in a variety of lengths. NO-OX Fittings include a PEEK 1/4-28 Nut, Tefzel Ferrule, and CTFE Insert that form an air and liquid-tight seal that s chemically inert (see Figure 2). Mobile phase contacts only the inert fitting components and NO-OX tubing s inert Teflon inner layer. Simply slide the nut and ferrule over the tubing, push an insert into the tube end, and connect finger-tight into any mating 1/4-28 port. No flanging or wrenches are required! NO-OX Tubing has a double wall that eliminates regassing. The inert inner Teflon wall carries the mobile phase. The non-wetted outer wall is made from a translucent, flexible polymer with extremely low gas permeability. NO-OX cuts regassing rates to negligible levels, while preserving Teflon s chemical resistance. NO-OX Tubing bends easily to fit your system s layout and cuts easily with a razor blade or Alltech Tubing Cutter. NO-OX Fittings connect to any 1/4-28 port without flanging tools or wrenches. The 1/8" OD x 1/16" ID matches the most popular Teflon tubing dimension, and connects easily to mobile phase inlet filters that slip fit into 1/16" (1.5mm) ID tubing. Immerse NO-OX tubing in the mobile phase reservoir by removing a section of the outer layer leaving only the inert Teflon layer exposed. NO-OX Anatomy Low Gas Permeability Outer Wall 1/8" 1.5mm Teflon Inner Wall NO-OX Tubing Cuts Regassing Rates to Negligible Levels Tefzel Ferrule (20242) 1/4-28 PEEK Nut (20116) 1 Oxygen (ppm) / Meter of Tubing Regassing Rate Through 1/8" OD x 1/16" ID Teflon and NO-OX Tubing at 1cc/min and 2.5cc/min Flowrates CTFE Insert (47122) Figure 2 Alltech NO-OX Tubing & Fittings DESCRIPTION QTY PART NO. PRICE NO-OX Tubing 1/8"OD x 1.5mm ID 10ft /8"OD x 1.5mm ID 50ft NO-OX Tubing (47100) Teflon NO-OX Figure 1 - Teflon tubing s high gas permeability lets air back into the mobile phase as it travels to the pump. The amount that enters depends on the tubing dimensions and flowrate, but no matter how well you ve degassed your mobile phase, some oxygen will reenter the system A NO-OX Fittings 1/4-28 NO-OX Fittings Kit, Nuts, 10 Ferrules, 10 Inserts Replacement 1/4-28 PEEK Nuts Replacement 1/8" Tefzel Ferrules Replacement CTFE Inserts

55 Mobile Phase Recyclers Alltech Solvent Recycler 3000 Recycles - Reduces Mobile Phase Purchase and Disposal Costs Validates - Generates Audit Trail for GMP, GLP, and ISO-9000 Compliance Cleans - AutoClean Accessory Reduces HPLC System Maintenance and Down-Time Alltech s Solvent Recycler 3000 combines reduced solvent use with validation and cleaning functions. Alltech's third generation solvent recycler, the Model 3000, continues to slash mobile phase costs potentially reducing solvent use by more than 90%! The Model 3000 also helps you comply with regulatory and quality guidelines with a Validation Output that records the Recycler s function. And, the Solvent Recycler 3000 s AutoClean Accessory reduces maintenance and down-time by automatically rinsing and re-equilibrating your HPLC system. During an isocratic HPLC analysis, the vast majority of the solvent leaving the detector is clean mobile phase eluting between peaks. Only those portions containing sample components (peaks) are actually contaminated, the rest is suitable for reuse. The Solvent Recycler 3000 throws away only the contaminated waste and returns the clean mobile phase to your reservoir. You purchase less solvent, spend less time preparing mobile phase, and dispose of less waste. In most cases, the Solvent Recycler 3000 will save you more than four times its purchase price every year you use it! The recycling function is accomplished with a Recycle Valve installed downstream from the detector (Figure 1). A Control Module uses the detector signal to identify contaminated mobile phase. When peaks are eluting, detector effluent goes to waste. Between peaks, clean mobile phase is sent back to the reservoir (Figure 2). User selectable parameters allow you to customize operation to your system and methods. You choose the minimum threshold which will divert flow to waste, as well as a delay time to allow the detector outlet line to be thoroughly flushed before returning flow to your mobile phase reservoir. The Model 3000 Solvent Recycler features a Validation Output to help you comply with regulatory, GMP, GLP, or ISO-9000 requirements. The Validation Output sends an auditable data trail to any standard recording device, giving you a continous documentation of Recycler operation. This operational record is a copy of your chromatographic signal with waste and recycle tick marks superimposed at the point of valve switching (Figure 3). The validation signal is separate from the one used by the integrator or data system, maintaining the integrity of your analytical results. An optional AutoClean Valve saves you even more money by automatically cleaning the HPLC system at the end of an analysis. Damaging buffers and strongly retained impurities are removed from the system, extending column, pump seal, and check-valve lifetimes. Not only do you save on replacing these components, but you also avoid costly down-time. By controlling the cleaning function through the recycler, all wash solvents are automatically diverted to waste, guaranteeing mobile-phase purity. The AutoClean Valve is installed on your pump s inlet line. At the end of an analysis, your autosampler or system controller signals AutoClean to deliver wash solvent to the pump. You select the duration of the wash cycle, and choose whether to reequilibrate with mobile phase and/or shut down the pump when finished. Purchase AutoClean when you buy the Solvent Recycler 3000, or add it later as your needs expand. Alltech s years of experience have created the best recycler on the market backed by the longest warranty available: three years on the controller and one full year on all valves. Microprocessor control, instrumentation-grade power supply and electronics, an easy-to-use interface, and storage of up to 10 user-defined methods make the Solvent Recycler 3000 the most rugged, reliable and versatile product of its kind. Years of mobile phase savings and reduced maintenance costs make it a valuable addition to your lab. Solvent Recycler 3000 Specifications Power: VAC, 50/60 Hz Display: Backlit LCD, 2-Line x 24-Character Wetted Parts: PEEK and Teflon Maximum Flow*: 50mL/min (as supplied with 1/16" tubing on each port) Recycle Valve Fittings: 1/16", 1/4-28 Flange-Free AutoClean Valve Fittings: 1/8", 1/4-28 Flange-Free Analog Input: 10mV, 100mV, 400mV, 1V, or 10V Dimensions: 13" L x 7.5" W x 2.5" H (33cm x 19cm x 6.35cm) Warranty: Control Module - 3 years Valves - 1 year *Maximum flow with short, 1/8" tubing on each port is 250mL/min

56 Mobile Phase Recyclers Autoclean Valve Injector Column Detector Recycle Valve Recycle Waste Mobile Phase Reservoir Wash Solvent Reservoir Pump Detector Output Waste Reservoir Fluid Path Electrical Path Recorder, Data System or Integrator Validation Output Solvent Recycler Control Module Recorder 4286 Figure 1 - The Solvent Recycler is composed of a control module, a Recycle Valve, and an optional AutoClean Valve. The Alltech Solvent Recycler 3000 fits easily in any LC System Typical Application Showing 75% Savings 7204 Delay Time 1% Threshold Recycle Waste Min. 1. Acetaminophen 2. Caffeine 3. Salicylate Figure 2 - Detector effluent is diverted to waste when peaks are present. Clean mobile phase is sent back to reservoir when peaks are absent. Solvent Recycler 3000 Validation Output 7993 Alltech Model 3000 Solvent Recycler Solvent Recycler Alltech Model 3000 Solvent Recycler Alltech Model 3000 Solvent Recycler with Autoclean Autoclean Accessory Replacement Parts Teflon Tubing 1/16" x 0.04" x 10ft Teflon Tubing 1/16" x 0.01" x 10ft /16" PEEK Flange-Free Nut, 5/pkg Kel-F 1/16" Flange-Free Ferrule, 10/pkg Preassembled PEEK Union Including: PEEK Nuts & 2 Double Sided Ferrules Recycle Valve for Model Replacement Fuse (0.2Amp) Signal Input Cable Validation Output Cable Remote Autozero Cable Min. FREE VIDEO To learn more about how the Solvent Recycler 3000 can save you up to 90% on Solvent Purchase and disposal costs, please request a FREE Video*, Part No *VHS NTSC Format. Figure 3 - The Validation Output documents Recycle Valve operation by superimposing 1 tick mark for waste and 2 tick marks for recycle over a copy of the chromatographic signal. 507

57 Mobile Phase Recyclers Alltech Solvent Recycler Junior Rugged and Reliable Basic Solvent Recycling Reduces Mobile Phase Related Costs up to 90% Costs Less than other Solvent Recyclers Pays for Itself Quickly Meets CE, CSA and UL Requirements Alltech s Solvent Recycler Junior reduces mobile phase consumption, potentially cutting solvent purchase and disposal costs by more than 90%. Solvent Recycler Junior is the basic, reliable, easy-to-use, low-cost alternative for labs that don t require the Solvent Recycler 3000 s sophisticated features such as Validation Output, AutoClean and multi-method storage. Solvent Recycler Junior quickly pays for itself, while helping our environment and saving precious natural resources. Solvent recycling saves money in three important ways. First, you use less solvent, so you buy less solvent. Second, you generate less waste, reducing waste disposal costs. Third, you spend less time preparing mobile phases. You ll quickly recover your initial investment in Solvent Recycler Junior, and continue to enjoy substantial savings for years to come. Solvent Recycler Junior Includes These Other Important Features: - Sends both positive and negative peaks to waste to maintain mobile phase purity - Has both manual and remote autozero for accurate recycling - Displays valve position continuously for easy identification of valve status - Indicates baseline level on an LED light bar for easier THRESHOLD and DELAY TIME adjustments - Sends detector effluent to waste whenever a remote override signal is received The easy-to-use Solvent Recycler Junior determines when solvent is recycled with three user-selectable parameters: RANGE, THRESHOLD and TIME DELAY. RANGE matches Solvent Recycler Junior s input range (10mV or 1V) with the detector s full-scale output range. When the detector s output signal exceeds the selected THRESHOLD value (0.1%, 0.5%, 1% or 5% of Full Scale), indicating a peak is present, the Recycle Valve sends the contaminated detector effluent to waste. The Recycle Valve returns to the recycle position after the detector signal falls below the THRESHOLD value and the TIME DELAY has elapsed. TIME DELAY holds the Recycle Valve in the waste position for the specified amount of time (10, 30 or 60 seconds) after the detector signal drops below the THRESHOLD value. The TIME DELAY accounts for tailing peaks and plumbing volume between the detector and the Recycle Valve. Set these three parameters, and Solvent Recycler Junior operates accurately and reliably with little or no intervention The Solvent Recycler Junior operates from an intrinsically safe 110V or 220V wall transformer and meets all CSA, UL and CE requirements. Solvent Recycler Junior includes all the fittings and tubing you ll need to safely and effectively recycle at flowrates up to 50mL/min. Handle flowrates as high as 250mL/min by changing the tubing connected to the Recycle Valve, or purchase an optional preparative Recycle Valve for flowrates as high as 350mL/min. How It Works Solvent Recycler Junior reduces mobile phase consumption while maintaining mobile phase purity. It operates on-line using the detector signal and an electrically actuated Recycle Valve installed between the detector and the waste reservoir. Solvent Recycler Junior monitors your detector s signal to determine when peaks and other contaminants are eluting from the system. When Solvent Recycler Junior detects a peak, the Recycle Valve diverts contaminated detector effluent to waste. When contaminants aren t present, the Recycle Valve sends clean detector effluent back to the mobile phase reservoir for re-use. Solvent Recycler Junior Specifications Power: 12 Volts 800mA Display: Red and Green LED Wetted Parts: PEEK and Teflon Maximum Flow*: 50mL/min. (as supplied with 1/16" tubing on each port) Recycle Valve Fittings: 5ft 1/16" tubing on each port Fittings: 1/16", 1/4-28 Flange-Free Analog Input: User Selectable Ranges: 10mV and 1V Dimensions: Weight: Warranty: Alltech Solvent Recycler Junior 7"L x 5.5"W x 2.75"H (17.78cm L x 13.87cm W x 6.985cm H) 2.5 lbs (1.134kg) Control Module - 3 years Valve - 1 year *Maximum flow with short, 1/8" tubing on each port is 250mL/min. DESCRIPTION PART. NO. PRICE Solvent Recycler Junior 110V V

58 Pump Accessories Alltech PEEK Mixing Tee Better Mixing Than a Conventional Tee Inert, Metal-Free Construction Ideal for High-Pressure Gradient Mixing 5616 Better mixing is the result of the turbulence generated by the introduction angle of the solvents, as well as the flow through a PAT (PEEK alloyed with TFE) filter element. As you can see from the baseline chromatograms, the two solvent streams mix more thoroughly than with a conventional tee. This reduction of baseline noise will improve the quality of your high pressure gradient mixing or post-column reactions. Only solvent contacts the PEEK housing and the PAT filter, providing a biocompatible, inert, and metal-free flow path. The sturdy PEEK housing is capable of withstanding pressures in excess of 6,000psig. The PEEK Mixing Tee has a 2.5µL internal volume, and comes complete with fittings and ferrules. Fitting Double-Sided Ferrule PAT Filter PEEK Housing Turbulence at Vertex Mixes Two Solvent Streams 1024 ASI Static Mixer Interchangeable Mixer Cartridges Selectable Volume Available in PEEK and Stainless Steel Mixers Suitable for Analytical and Micro LC Flowrates* The ASI Static Mixers use a highly 4707 efficient liquid-liquid shearing interface which induces vortex mixing over a wide flowrate range. The versatile cartridge design is available as an in-line, binary, or ternary inlet housing. The Analytical Volume housings accept any of the 350 or 500µL mixer cartridges. The Low Volume housings accept any of the 50, 150 or 250µL mixer cartridges. The Micro Volume housings accept any of the 2, 5, 10 or 25µL mixer cartridges. All are rated to 5000psig. Choosing the Appropriate Mixer Volume Cartridge* Choosing the right size is a compromise between delay volume, mixing noise and step gradient definition and repeatability. Use the following guidelines to help choose the appropriate mixer cartridge. For any given flowrate, the more mixing volume, the better the mixing and lower the baseline noise. The smaller the mixing volume, the better the difinition and sharpness of step gradients. High pressure multi-pump gradient systems typically require far less mixing volume than low pressure singlepump gradient systems. *Other cartridge volumes available, call for assistance. Alltech Peek Mixing Tee DESCRIPTION QTY PART NO. PRICE Mixing Tee with Fittings Ea Replacement Fittings Replacement Ferrules Toroid Mixer High Efficiency Mixer for Preparative Chromatography Precise and Reliable The unique design of the Toroid Mixer extends the mixing characteristics of a pulse 4708 dampener in higher flowrate applications. High efficiency mixing yields reproducible quantitation, better reproducibility of retention times, and reduced baseline noise due to uniform solvent composition. Featuring a clean-swept mixing chamber, the Toroid Mixer has no motors or moving parts. Toroid Mixer Specifications Internal Volume: 5mL Delay Volume: 17mL to 97% Flow Range: to 200mL/min Maximum Pressure: 6,000psig Flowpath: PEEK Toroid Mixer Toroid Mixer, Biocompatible ASI Static Mixers SS PEEK DESCRIPTION PART NO. PART NO. PRICE Analytical Volume Housing In-Line Binary Inlet Ternary Inlet Analytical Volume Mixer Cartridges 350µL µL Low Volume Housings In-line Binary Inlet Ternary Inlet Low Volume Mixer Cartridges 50µL µL µL Micro Volume Housing In-Line Binary Inlet Ternary Inlet Micro Volume Mixer Cartridges 2µL µL µL µL

59 INC. O R E E TECHNOLOGIES OPTI- PRIME OPTI- PRIME P O R TL AN D INC. O R E Pump Accessories Hamilton 1000 Series Priming Syringe For Waters Pumps This 10mL Syringe is used for priming Waters pumps Series Priming Syringe 10mL 1010W Gas Tight Priming Syringe Draw Needles for Waters Pump Pump Inlet Kit Rapid Priming and Solvent Changeover Filtration of Mobile Phase The Alltech Pump Inlet Kit is designed to connect the mobile phase reservoir to the pump inlet. A three way valve allows rapid priming and solvent changeover. A luer-lock adaptor in the side port allows easy attachment of a syringe for priming. A 2 micron inlet filter element removes particulates from your solvent stream. Pump Inlet Kit 5617 OPTI-PRIME Priming Valve Convenient - Onehanded Operation Prime Pump Efficient - No need to Remove Syringe Inert - PPS, TFE, and 316SS Wetted Surfaces 1896 The syringe of the OPTI- PRIME is also the handle to open the valve, 1898 allowing one-handed operation. Once at the 45 open position, air bubbles rise to the top of the syringe, allowing purging and priming without removing the syringe. OPTI-PRIME Valve OPTI-PRIME Priming Valve OPTI-PRIME Priming Valve w/safety Syringe Optimize Safety Syringe In-Line Bubble Trap This handy accessory installs on pump inlet lines by slipping onto the connecting tubing. As bubbles develop in the solvent line, they are trapped before reaching the pump. OPTIMIZ P O R TL AN D OPTIMIZE TECHNOLOGIES Pump Inlet Kit Includes: 1 Hamilton 3-way valve, 1 Luer Adaptor, 2µm Mobile Phase Filter, 100cm x 1/8" OD x 1/16" TFE Tubing, 2 1/8" Flange-Free Fittings and Ferrules Replacement Filter Element 9400 LO-Pulse Dampener 95% Pulse Reduction Low Internal-Volume Available in SS or PEEK The LO-Pulse is a lowvolume, diaphragm-type pulse dampener with a small internal volume. The unit consists of an inert, flexible diaphragm suspended between a compressible fluid and the mobile phase. As a pressure pulse enters the unit, the diaphragm transfers the pulse to the compressible fluid resulting in a 95+% reduction in pressure fluctuation. The low internal-volume (only 900µL at 6,000psig) and flow-through design and minimize gradient delays. LO-Pulse Dampener Specifications Flow Path Material: PEEK or 316 Stainless Steel Internal Volume: 0.9mL Workable Pressure Range: psig Maximum Temperature: 100 C Damper Mechanism: Compressible Fluid 2350 In-Line Bubble Trap 4042 LO-Pulse Dampener In-Line Bubble Trap with Bracket 1/16" (1.5mm)* * For Use with this ID Teflon Tubing. Stainless Steel PEEK Diaphragm Replacement Kit

60 Pump Accessories Alltech Conventional Pressure Gauges Connects via 1/16" Tubing and Fittings Inert Stainless Steel Construction Built-in Connecting Tee These gauges are designed for connection to a single 1/16" tubing stem, and are equipped 2349 with a connecting tee for attaching it in-line to the solvent stream. By connecting with standard fittings, there is no need for pipe-thread adaptors, typical of many gauges. Each gauge is constructed of 316 stainless steel and features an easy-to-read 2-1/2 inch face plate. Alltech Pressure Gauge Specifications Material: 316 Stainless Steel Maximum Temperature: 60 C Maximum Pressure: Varies Thread Type: UNF Typical Use: In-line Installation Alltech Pressure Gauges Pressure Gauge w/connecting Tee 0-100psig psig psig psig psig Alltech Pressure Relief Valve Protect Flow Cell Windows From High Pressures Adjustable From 0 to 200psig Will Not Affect Peak Shape Biocompatible PEEK and Kalrez Construction Easy to Connect Complete with 1/16" Finger-Tight Fittings 4705 Alltech Adjustable Backpressure Regulators Constant Backpressure, Even with Changing Flow Ultra-Low Deadvolume - Under 0.6µL Available in 4 Different Pressure Ranges Easily Adjusts by Hand - No Cartridges to Change The Alltech Backpressure Regulator prevents bubbles from forming in your flow cell by exerting a constant pressure. This pressure does not vary with mobile-phase composition 4704 or flowrate. And now with a new port configuration, the Alltech Backpressure Regulators all have an internal volume of less than 0.6µL! These regulators are available with four different operating pressure ranges: 0-100psig, 0-300psig, psig, psig. They also use a convenient, knurled knob for adjusting the pressure, eliminating the need for changing cartridges, and allowing adjustments to be made without interrupting flow. Alltech Backpressure Regulators Alltech Backpressure Regulators 0-100psig psig psig psig Optimize Fixed Backpressure Regulators Flow-through Design Use In-line or as a Terminator May Be Immersed in the Waste Solvent Bottle 1/4-28 Ports for Tubing Connections The Alltech Pressure Relief Valve uses a set-screw to adjust the upper pressure limit from 0 to 200psig. When the pressure exceeds this, flow is diverted to an overflow line, safely releasing the pressure and preventing damage to the flow cell windows. Alltech Pressure Relief Valve Alltech Pressure Relief Valve These flow-through, back-pressure regulators prevent solvent outgassing in your LC detector. More than a flow restrictor, Optimize fixed regulators maintain a consistent back pressure, regardless of viscosity or flow rate. Pressure ratings are preset to their listed value. Internal volume is 100 microliters. They are supplied with fittings, and complete instructions. Optimize Backpressure Regulators psig psig psig psig psig

61 Pump Check Valves ASI Self-Priming Cartridge Check Valves Self-Priming Rugged Construction Convenient and Economical Superior Flow Stability With the ASI valve, priming is easy. Open the 2240 pump purge valve and turn on the pump. Your pump will prime itself, even if the head and intake lines are completely dry. You will not need to use syringes or drawoff valves to prime your pump. The valve will not crush, crack, or leak due to high pressure. The ASI cartridge is designed to transmit the load through the valve casing, rather than the seat. This permits a 15,000psig maximum operating pressure. When it s time for routine maintenance, you only replace the cartridge, not the entire assembly. The cartridge costs no more than most conventional valve rebuild kits, and you will not spend time chasing ruby balls all over the lab bench. Every valve is tested prior to shipping to ensure it passes a stringent set of performance specifications. A replaceable 2µm outlet filter insures clog-free operation and protects the column from pump wear particles. Flow ml/min. Flow ml/min Run Flowrates of ASI Valves for Waters Pumps Flowrates of Waters Valves Actual Average Flowrate: 0.994mL/min. Actual vs. Expected Flow Deviation: % Actual Average Flowrate: 1.000mL/min. Actual vs. Expected Flow Deviation: % Run Pump: Detector: Expected Flow: Waters 6000A Humonics P mL/min. ASI Check Valve Assembly INLET OUTLET PUMP MODEL PART NO. PART NO. PRICE Assembly (Holder and Cartridge) For: ABI/Kratos 1400A, 1406A Beckman 110, 112, 114, 116, , 125, 126, 127, 128 Bio Rad 1330 and Gilson 5 and 10s, SC Hewlett Packard Hitachi 655, L6000, L6200, L6200A LDC Constametric I, II, III, IIIG, and 3000 Series LKB Perkin Elmer Series 4, 200, 400, , 620, 4000 Perkin Elmer Series 1, 2, 3, 3B, Shimadzu LC600, LC6A, LC7A, LC9A, LC10A, LC10AS, LC10AT Spectra-Physics 8100, 8700, 8700, , 8810 SSI Model 200, 220, 222, SSI Model 350 and Accuflow Varian 5000 Series N/A Waters M45, 510, 590, and 6000 Waters M501 and 600E Waters 6KEF, 6KAEF, EF, 600EF ASI Replacement Cartridges INLET OUTLET PUMP MODEL PART NO. PART NO. PRICE ASI Replacement Cartridges For: ABI/Kratos 1400A, 1406A Beckman 110, 112, 114, 116, , 126, 127, 128 Bio Rad 1330 and Gilson 5 and 10s, SC Hewlett Packard Hitachi 655, L6000, L6200, L6200A LDC Constametric I, II, III, IIIG, and 3000 Series LKB Perkin Elmer Series 4, 200, 400, , 620, 4000 Perkin Elmer Series 1, 2, 3, 3B, Shimadzu LC600, LC6A, LC7A, LC9A, LC10A, LC10AS, LC10AT Spectra-Physics 8100, 8700, SSI Model 200, 220, 222, and SSI Model 350 and Accuflow Varian 9010 N/A Waters M45, 501, 510, 590, E, and 6000 Waters 6KEF, 6KAEF, 510EF, 600EF

62 Pump Check Valves OPTI-MAX Cartridge Check Valves Economical, Disposable Cartridge with Reusable Holder Available with PEEK or SS Cartridges Same Cartridge Fits both Inlet and Outlet Housings Cartridge Fits Multiple Housing Brands for Reduced Inventory The OPTI-MAX Cartridge Check Valve System consists of a replaceable cartridge, plus custom designed housings for virtually all major brands of HPLC pumps. This versatile and unique system allows one replacement cartridge to fit multiple pump brands, in both inlet and outlet OPTI-MAX housings. Cartridges are available in passivated 316 stainless steel or PEEK with 1/16", 1/8", or 3/16" diameter balls and seats for various pump models. Housings come complete with cartridge. Replacement cartridges are also available. Bubbles of nitrogen/min at 90psig which leak from ball & seat set OPTI-MAX Check Valve Assembly (Holders and Cartridges) INLET OUTLET DESCRIPTION PART NO. PART NO. PRICE Standard Series (1/8" Ball) For: ABI/Kratos Spectraflow Agilent/HP 1050, * Bio-Rad Bischoff SM909 Analytical Dionex DQP, GPM-1, DRP Dionex GPM-2,DXP, AGP Analytical, 2000, 4000 Gilson/Rainin 5, 10, 25mL S, SC Heads LDC Milton Roy Analytical Perkin-Elmer Inlet Model 250, Series 4, 200, 400, 410, 620, Integral 4000 Perkin-Elmer Series 1, 2, 3, B, 10 Shimadzu LC-6A, LC-10AS Spectra-Physics 8100, 8700, Series, P-Series Varian 9000 Star, 9010, Waters M45, M45G, M501, 6K, KA, 510, 590, 600E, 610 Low Flowrate Series (1/16" Ball) For: Hitachi 655, L6000, L6200, L6200A Hitachi L-7100 (LaChrom) Shimadzu LC-10 AT, LC-10ATVP Shimadzu LC-10AD, LC-600, LC-9A Waters 2690 Alliance, Waters 625, Higher Flowrate Series (3/16" Ball) For: Beckman *Replace Cartridge for Active Inlet Valve Industry Standard Ball & Seat OPTIMIZE Ceramic Ball and Seat Replacement OPTI-MAX Cartridges DESCRIPTION QTY PART NO. PRICE Standard Series (1/8" Ball) PEEK Stainless Steel OPTI-MAX Cartridges Outperform the Industry Standard in the Nitrogen Leak Test. (Bubbles per minute leaking past the ball and seat; Nitrogen at 90psig) Low Flowrate Series (1/16" Ball) PEEK Stainless Steel Higher Flowrate Series (3/16" Ball) PEEK

63 Pump Pistons and Seals ASI Pistons and Seals for HPLC Pumps ASI offers proprietary Ultra High Molecular Weight-Polyethylene (UHMW-PE) blend and PTFE-based (Teflon ) material for the piston seal jacket. The ASI proprietary UHMW-PE blend is recommended for most applications. It offers superior lifetime and wear characteristics, and is resistant to a wide range of HPLC solvents. The ASI PTFE-based (Teflon ) blend offers the best solvent compatibility, but is a softer material and may have a shorter lifetime than UHMW. In some applications, the PTFE compound provides a better material choice because of the compliant nature of the material, and is offered as the standard material for these pumps. ASI also provides precision-manufactured replacement pistons. Superior surface finish of the piston rods improves piston seal lifetime. ASI Pistons MANUF. ALLTECH DESCRIPTION PART NO. PART NO. PRICE Pump Pistons For: ABI/Kratos/Gynkotek Beckman 110, Beckman 114, 116, Bio-Rad 1330, Gilson 10, SC Gilson 5SC Hewlett Packard Hewlett Packard Hitachi 655, L6000, L6200, L6200A LDC (all analytical pumps) Shimadzu LC 6A Shimadzu LC-600, LC-9A, LC-10AD Spectra-Physics 8800, 8100 A Spectra-Physics 8700 A Varian Waters M-45, Waters M-510, 590, , 6000 Waters Ext. Flow 510EF, EF, 600EF, 610EF, 650EF, 6000EF, 6000AEF 2334 ASI Pump Seals MANUF. ALLTECH DESCRIPTION QTY. PART NO. PART NO. PRICE Pump Seals For: ABI/Kratos/Gynkotek Ea ABI/Kratos/Gynkotek Beckman 110 Ea Beckman Beckman 114, 116, 126 Ea Beckman 114, 116, Bio-Rad 1330, 1350 Ea Bio-Rad 1330, Gilson/Rainin 10S, SC Ea Gilson/Rainin 10S, SC Gilson/Rainin 5SC Ea Gilson/Rainin 5SC Hewlett Packard 1090 Ea Hewlett Packard Hitachi 655, L6000, Ea L6200, L6200A Hitachi 655, L6000, L6200, L6200A LDC (analytical pumps) Ea LDC (analytical pumps) LKB 2150 Ea LKB Spectra-Physics 8800, Ea A Spectra-Physics 8800, Varian 9010 Ea Varian Waters M45, 501, 510, Ea , 600, 6000 Waters M45, 501, 510, , 600, 6000 Waters M45, 501, 510, Ea , 600, 6000 (Teflon) Waters M45, 501, 510, , 600, 6000 (Teflon) Waters Ext. Flow UHMW Ea Waters Ext. Flow UHMW

64 Pump Pistons and Seals Optimize Pistons and Seals for HPLC Pumps Optimize Technologies offers two distinct families of seals, allowing your pump to run at optimum performance given any set of variables. OPTI-SEAL OPTI-SEAL offers improved performance for all major brands of analytical pumps, and compatiblity with most HPLC solvents reduces particle shedding and wear of the seal 2378 and piston. These seals are made from the proprietary UHMWPE blend, OS-10.1, which significantly reduces friction and shedding. The low shedding prevents clogged frits and backpressure-related problems. They are better suited to aqueous solutions and lasts up to seven times longer compared to PTFE-based seals. Improved Teflon -Blend (ITB ) Typically as a PTFE-based seal wears, tiny particles (<0.5µm) are shed from the pump seal and swept into the mobile phase stream. These tiny 2379 particles cause problems which are often difficult to troubleshoot. ITB seals are made from ITB -12, a proprietary PTFE blend designed to shed particles large enough to remain on the surface of a 2 micron frit. In this way, backpressure problems are greatly reduced. Optimize Pistons The items listed below are replacement pistons for original equipment manufactured by various instrument suppliers. All of these pistons meet or exceed manufacturer s standards. Optimize Pistons DESCRIPTION MANUFACTURER ALLTECH PART NO. PART NO. PRICE Pump Pistons For: ABI/Kratos Spectraflow Agilent/HP 1050, Agilent/HP Beckman 110A, 110B, 112, 112M Bio-Rad Bischoff SM909 Analytical Dionex Analytical Gilson/Rainin 10mL S, SC Hitachi 655, L6000, L6200/A, (LaChrom) LDC, Milton Roy Perkin-Elmer Model 250, 200, (N , 620, Integral 4000 Shimadzu LC-6A LC-1A, LC-10AS, LC-10AT, LC-10ATVP Shimadzu LC-600/LC-9A, LC-10AD Spectra-Physics 8800, 8810, A P-1000, P-2000, P-4000 Varian 9000 Star, 9010, Waters M510, M590, M600E, M610, M6000, M6000A Waters 2690 Alliance Optimize Opti-Seals MANUFACTURER'S OPTI-SEAL ITB SEAL MANUFACTURER DESCRIPTION PART NO. QTY PART NO. PRICE PART NO. PRICE ABI/Kratos Spectraflow * Agilent/HP 1050, * Ea Ea Bio-Rad 1350, * Ea Gilson/Rainin 10mL S, SC * Ea Hitachi 655, L6000, L6200, L6200A, L-7100, LaChrom * Ea LDC Milton Roy * Ea Perkin-Elmer Model 250, Series 4, 200, 400, 410, 620, * Integral 4000,Series 1, 2, 3, 3B, 10 Ea Shimadzu LC-6A, LC-7A, LC-10AS, LC-10AT, LC-10ATVP * Ea LC-600/LC-9A, LC-10AD * Ea Spectra-Physics 8800, 8810, P-1000, P-2000, P-4000 A * Ea Waters M45, M45G, M501, M510, M590, M600E, 22934* M610, M6000, M6000A Ea Waters 2690 Alliance Ea

65 SelectPRO Column Selector Alltech SelectPRO Column Selector Streamline Method Development and Validation Screen Multiple HPLC Columns Quickly and Automatically Eliminate Sample Carry-over and Minimize Dispersion with Low Dead-Volume Valve Architecture Alltech s SelectPRO Column Selector is a self-contained, electrically operated instrument for automated column selection. A SelectPRO Column Selector is a powerful tool for quickly screening multiple columns for the best separation. After column selection and method optimization is achieved, use the Column Selector to quickly validate methods using different lots of the same packing material or, alternatively, different columns from the same lot. Many laboratories have a number of users sharing the same system. An Alltech automated column selector lets multiple users select methods using the correct column for their assay and offers convenient washout and column storage. Different samples can be run at night and over weekends using different methods, better utilizing existing equipment and increasing productivity. The selected column is indicated by a bright digital display on the front panel. Select columns remotely by a built-in instrument compatible electronic interface, or locally by push button. Remote column selection is easily accomplished using 4-line BCD. Column Selector 4534 Design Features: Eliminates unswept volume, therefore dispersion is minimized and potiental carryover problems are eliminated. Pinch clips simplify column mounting and removal Built-in drip tray provides safe and convenient solvent containment for leaks and spills Magnetically secured cover maintains environmental isolation and stabilizes ambient temperature Side tubing fasteners organize tubing connections Accommodates columns in lengths of 3-35cm (2-14") and diameter of cm ( ") SelectPRO Column Selector Specifications CE Mark: Yes Dimensions: 22" H x 9.8" W x 12.8" D (55.9cm H x 24.9cm W x 32.5cm D) Maximum Pressure: 5000psig (345 bar) Flow Passage: 0.6mm (0.024") and 0.4mm (0.015") Environment: 4-40 C, <95% humidity (non-condensing) Supplied with: nuts and ferrules, 3.5m 1/16" OD PEEK tubing, universal power supply, power line cord, and interface cable. Warranty: 1 year Control: 4 Line BCD SelectPRO Column Selectors 4535 Column Selector with Cover CONTROL LOGIC PART NO. PRICE Six Column Selectors Stainless Steel PEEK Three Column Selectors Stainless Steel PEEK SelectPRO Valve Rhebuild Kits Valve Rhebuild Kits For Six Column Selectors For Three Column Selectors

66 SelectPRO Valve Systems Alltech SelectPRO Automated Valve Systems Increase Productivity Save Time with Unattended Operation Available in Stainless Steel or PEEK Alltech's SelectPRO valve systems are stand-alone, electronicallycontrolled, motorized instruments. These easy-to-use units increase productivity and save time and money by eliminating repetitive, manual switching. Built-in electronic communications make SelectPRO products compatible with common remote instruments and laboratory computer systems. SelectPRO instruments are available in several configurations allowing you to automate a wide variety of fluid-processing applications such as methods development, solvent switching, stream sampling, sample preconcentration, fraction collection, and many others. SelectPRO valve position is always indicated by a digital display on the front panel. Operation is easy with manual switching on the front panel or automated switching with a builtin electronic communication interface. Automated control through the communication interface is accomplished by either level logic or four-line BCD control. All line controls require contact closure or TTL outputs. 2-Position Fluid Processors 6 or 10-port configurations; PEEK or SS; Ports - On-line sample enrichment to decrease total analysis time. - Sample loop selection for versatile injection capability. - Alternate column equilibration for maximum sample throughput. 2-Channel Selector with By-Pass PEEK or SS; Ports - Column selection with internal by-pass reduces equilibration time during solvent changeover. - Selection of detectors without re-plumbing SelectPRO Valve System Specifications CE Mark: Yes Dimensions: 11" D X 2.5" W X 4.25" H Maximum Pressure: 5000psi (345 bar)* Warranty: 1 Year 2-Postion Valve Control: Level Logic Multi-Position Valve Control: 4-Line BCD Supplied With: Interface Cable and Universal Power Supply *Max pressure for 6-position solvent selector is limited by fittings Alltech SelectPRO Valve Systems LEVEL 4-LINE LOGIC BCD DESCRIPTION PART NO. PART NO. PRICE SelectPRO Valve Systems 2-Position 6-Port Fluid Processor, SS Position 10-Port Fluid Processor, SS Position 6-Port Fluid Processor, PEEK Position 10-Port Fluid Processor, PEEK Channel SS Selector with By-Pass Channel PEEK Selector with By-Pass Position SS Selector Position PEEK Selector Tubing 6-Position Solvent Selector, 1/16" Tubing 6-Position Solvent Selector, 1/8" Position Selector PEEK or SS; Ports - Selection of up to ten columns using two valves to accelerate methods development and increase column lifetime. - Increase precision with automated fraction collection. 6-Position Solvent Selector 1/16" or 1/8" OD tubing with 1/4-28 Ports - Selection of various mobile phase compositions for hands-off methods development. - Overnight, unattended column cleaning/conditioning SelectPRO Valve Rhebuild Kits For 2-Position, 6-port Fluid Processor* For 2-Position, 10-port Fluid Processor* For 2-Channel Selector with By-Pass* For 10-Position Selectors* For 1/16" Tubing, 6-Position Solvent Selectors For 1/8" Tubing, 6-Position Solvent Selectors * Suitable for Stainless Steel or PEEK Version

67 Rheodyne Valves Rheodyne Matrx Semi-Automatic Injection Valves Electronic Manual Valves Eliminate Actuation Inconsistencies Simple to Install Without Special Software Capable of Full Automation for Unattended Operation Rheodyne Model 7725 and 9725 Dual Mode Injection Valves Available in Stainless Steel or PEEK Make-Before-Break (MBB ) Switching for Uninterrupted Flow Wider Port Angles Provide Improved Fitting Access Rheodyne s next generation of valves offer the speed, precision and flexibility that today s applications require. Matrx Semi- Automatic Valves combine the ease of use of the 7725i with the precision actuation of motorized valves. They can be operated either by push button, allowing them to function as a manual valve, or by contact closure for complete remote control. With its specially designed needle port, sample is loaded directly into the valve. The push of a button injects your sample without the inconsistencies of manually turning a handle. Unlike any other manual valve, the Matrx Semi-automatic Injector is also capable of complete automation. By connecting the valve to a single contact closure (two wires), a sample can be loaded during system equilibration and injected unattended when the system is ready. No more waiting for the LC ready signal, just load the sample and forget it. The 7725 and 7725i are capable of injecting volumes of 1µL to 5mL with high precision. The 7725i features a built-in positionsensing switch, providing the chromatograph with a reproducible start signal. The 7725 and 7725i come with a 20µL sample loop. Other loops are available including a 2µL internal sample loop, providing greater versatility in your sample size. The 9725, 9725i are biocompatible versions of the 7725 and 7725i injectors. Wetted materials are PEEK and Tefzel, making it ideal for applications requiring a biocompatible or metal-free flow path. A 20µL PEEK sample loop is included. Also available is the Suction Needle Adaptor which eliminates exposure of the sample to the metal of a syringe needle. These valves feature the new Make-Before-Break system, which prevents flow interruptions while switching. This protects any columns, detectors, or pumps which might be affected by flow or pressure fluctuations. Matrx Semi-Automatic Injector Specifications Maximum Pressure: 5000psig (345 bar) Flow Passages: 0.25mm (.010 ) diameter Power Requirements: VAC, 50/60 Hz CE Mark: Yes Remote Control: One-Line contact closure (open = valve position 1, closed = valve position 2) Operating Temperature: 4 40 C Dimensions: 10.2cm H x 7.6cm W x 12.7cm D Note: Refer to the Flow Diagram located on page 519 for further reference, Rheodyne Dual Mode Analytical Injection Valves Stainless Steel Injection Valves 7725 (SS) i w/position-sensing Switch (SS) Rheodyne Matrx Semi-Automatic Injection Valve Matrx injector, SS Matrx injector, PEEK PEEK Injection Valves 9725 (PEEK) i w/position-sensing Switch (PEEK) Accessories Suction Needle Adaptor Position Sensing Switch for 7725i & 9125i

68 Rheodyne Valves Rheodyne Model 7125 and Dual Mode Injection Valves 5,000psig Maximum 5µL to 5mL Sample Loops Position-Sensing Switch Available Rheodyne Model 7010 and 9010 Single Mode Injection Valves High Volumetric Precision Low Volume Flow Passages Biocompatible Model 9010 Available These feature the original valve design that the 7725 is based on. The 7125 has achieved an outstanding reputation for ease-of-use, versatility, and reliability. The is functionally the same as the 7125, but with a biocompatible flow path. The wetted materials are: Titanium, Tefzel, and ceramic. Pump Waste Flow Diagram Sample In Pump Waste Sample In The Rheodyne Model 7010 Sample Injection Valve injects sample volumes of 5µL or larger by means of a removable sample loop. The Model 9010 tolerates the aggressive mobile phases commonly used for separating biological molecules. Neither the sample, nor the mobile phase comes in contact with metal. Functionally similar to the 7010, the 9010 is more inert, made from materials such as PEEK, Tefzel and ceramic. Since these valves are single mode valves, they must be loaded by the complete-filling method. Use of the Loop-Filler Port minimizes sample waste when loading. The Loop Filler Port has a needle insertion port with a very small dead volume. An adjustable Teflon seal accommodates needles ranging from 0.018" to diameter. The 9010 comes with a built-in position-sensing switch. The 7010 may have one added as an accessory. Both models come standard with a 20µL sample loop. Column Position A (LOAD) Column Position B (INJECT) Figure 1 - Flow diagrams for Rheodyne front loading dual mode injectors Rheodyne Single Mode Analytical Injection Valves Rheodyne Dual Mode Analytical Injection Valves Dual Mode Injection Valves 7125 (SS) 7125RV (Titanium) Accessories Position Sensing Switch for 7125 or Injectors Suction Needle Adaptor Single Mode Injection Valves 7010 (SS) 7010RV 7010 (Titanium) (PEEK) 9000RV Accessories Position Sensing Switch for 7010 Injectors Loop Filler Port (SS) 7044 Loop Filler Port (PEEK) Needle Port Fitting

69 Rheodyne Valves Rheodyne Model 8125 Low-Dispersion Micro-Scale Injector Versatile! - Works with Microbore (1mm, 2mm) and Conventional (2-6mm) ID Columns 0.25mm (0.010") Flow Passages Built-In Position Sensing Switch Rated to 5,000psig Rheodyne Model 7410 Low-Dispersion Micro-Scale Injector 0.5µL to 5µL Removable Internal Sample Loops Designed for 1-2mm ID Columns High Volumetric Precision Rated to 5,000psig The 8125 is a low-dispersion analog of Rheodyne s 7125 valve. It features reduced diameter flow passages, a new port geometry for easier loop attachment, and a built-in position sensing switch. Flow passages in the 8125 are only 0.25mm in diameter, resulting in a significant reduction in dispersion. The lower dispersion makes the 8125 valve suitable for use with conventional analytical columns (2 to 6mm ID) as well as with microbore (1mm and 2mm ID) columns where minimum extracolumn volume is critical. The 8125 valve has unique dual size ports for tubing connections. This allows either 1/16" OD or 0.02" OD tubing to be used. Connections to 1/16" column end fittings are facilitated with a connecting tube supplied with the valve. The smaller flow passages also result in more resistance to flow. This makes it harder to load large sample volumes. The maximum recommended sample volume for the 8125 valve is 500µL. All sample loops are externally plumbed Rheodyne Model 7410 Sample Injection Valve is a single mode injector where by sample is loaded by the complete filling method using a loop filter port. Interchangeable internal loop discs of , 2-, and 5µL are ideal for micro-lc work. This injector can be used with Rheodyne loop filler port accessories, position sensing switches, and mounting panels. The valve has four ports which are threaded to accept Rheodyne male nuts and ferrules (compression-type tube fittings) for 1/16" OD stainless steel tubing. Rheodyne Low-Dispersion Injection Valve Dual Mode Injector Model 8125 Sample Injector w/5µl Loop 8125RV Accessories Ferrule for 0.02" Tubing Rheodyne Low-Dispersion Injection Valve Single Mode Injector Model 7410 Valve 7410 RV Internal Loop Discs 0.5µL Loop Disc for µL Loop Disc for µL Loop Disc for µL Loop Disc for

70 Rheodyne Valves Rheodyne Model 7520 Micro-Scale Injector Designed for Narrow Bore (1-2mm) Columns 0.2µL to 1µL Interchangeable Sample Chamber 0.13mm (0.005") Flow Passages Built-in Needle Port with 0.2µL Hold up Volume Rated to 7,000psig Rheodyne Matrx Nano-Scale Motorized Injectors 10µL Internal Injection Loop 0.1mm (.004") Flow Passages Operate by Either Push Button or Complete Remote Control The model 7520 Syringe- Loading Micro Injector is designed for microbore HPLC columns. It injects submicroliter samples with high precision and low dispersion. The standard sample size is 0.5µL. Accessory chambers are available for 0.2µL and 1.0µL volumes. Figure 1 is a flow diagram of the The needle port in the inlet stator includes a Teflon needle seal near the bottom of the port. A spring keeps the seal compressed so it grips the needle tip. The volume between the needle tip and the sample chamber is 0.3µL. This small volume, as compared to external filler ports, greatly reduces sample loss. The 7520 valve is rated to 7,000psig maximum. To conserve seal life, the valve is factory preset to withstand 5,000psig maximum. The high-pressure seal is adjusted via a single hex bolt on the front of the valve. The 7520 valve accepts all syringes designed for use with all other Rheodyne valves. Inlet Stator Rotor Sample Needle Port Sample Chamber Pump Sample Needle Port Sample Chamber Pump 5496 Rheodyne has created the world s smallest injection valves in package size, internal volume, and dispersion. With a mere 20µL internal volume and more importantly, outstanding dispersion characteristics, the Matrx Nano-Injector is the ultimate solution for nano-scale sample injection. It comes with a noninterchangeable 10µL internal sample chamber. Matrx Nano-Valves can be operated either by push button, allowing them to function as a manual valve, or by contact closure for complete remote control by connecting the valve to a single contact closure (two wires), a sample can be loaded during system equilibration and injected unattended when the system is ready. No more waiting for the LC ready signal, just load the sample and forget it. Outlet Stator Figure 1 Column Position A (LOAD) Waste Rheodyne Micro-Scale Injection Valve Column Position B (LOAD) Waste 5497 Matrx Nano-Scale Injector Specifications Maximum Pressure: 5000psig (345 bar) Flow Passages: 0.1mm (.004 ) diameter Power Requirements: VAC, 50/60 Hz CE Mark: Yes Remote Control: One-Line contact closure Communication (open valve position 1, closed = valve position 2) Operating Temperature: 4 40C Dimensions: 10.2cm H X 7.6cm W X 12.7cm D Single Mode Micro-Scale Injector 7520 Micro Sample Injector 7520RV with 0.5µL Sample Chamber Internal Sample Loops 0.2µL Sample Loop µL Sample Loop µL Sample Loop Rheodyne Matrx Nano-Scale Injection Valves Nano-Scale Injector Stainless Steel (10nL Internal Loop) Nano-Scale Injector PEEK (10nL Internal Loop)

71 Rheodyne Injectors and Switching Valves Rheodyne Model 3725 Prep-Scale Injectors Sample Range 100µL to 20mL Flowrates from 10 to 800mL/min; Pressures to 5,000psig Available in PEEK or SS Uses 16 guage Needle 1.0mm (0.04") Flow Pressure Rheodyne Matrx Two-Position, Six- and Ten- Port Motorized Valves Operate by either Push Button or Complete Remote Control Available with Analytical or Nano-Scale Switches Ideal for Micro LC and LC/MS Work Rheodyne introduces the new Matrix line of two-position, sixand ten-port motorized valves. These automated switching valves can be operated either by push button, allowing them to function as a manual valve, or by contact closure for complete remote control. For multiple automated valve applicatons, Matrix s unique snap'n'stack system allows units to be stacked vertically to connected horizontally to conserve valuable bench space and reduce connection volumes. The Matrx family of switching valves includes six and ten-port valves in both analytical-scale and nano-scale. The analytical flow passages are 0.25mm (.010 ) diameter, while the nano-scale valve incorporates flow passages of 0.10 mm (0.004") and provides <25 nl port-to-port volume. The nano-scale valves are ideal for low flow, dispersion sensitive applications. The six and the ten-port can be used for stream selection, on line sampling and column selection. The small port sizes and short flow paths make these platform variations a significant improvement in the technology related to micro LC and micro LC/MS. These injectors are used with preparative HPLC columns from 1 to 10cm diameter. They have the ease of use and versatility of Rheodyne s analytical-scale sample injectors, plus the capacity for large sample volumes and flowrates. The Model 3725 Valves are available in SS or PEEK, and with a built-in position sensing switch (Model 3725i-038 or 3725i). Each model is supplied with a 10mL loop and 1/8" fittings must be used. An optional port adaptor can be used to connect 1/16" tubing Matrx 6- and 10-Port Switching Valve Specifications Maximum Pressure: 5,000psig (345 bar) Flow Passages Nano: 0.10mm (.004 ) diameter Analytical: 0.25mm (.010 ) diameter Power Requirements: VAC, 50/60 Hz CE Mark: Yes Communication: One-Line contact closure (open = valve position 1, closed = valve position 2) Operating Temperature: 4 40 C Dimensions: 10.2cm H X 7.6cm W X 12.7cm D Rheodyne Prep-Scale Injection Valves Prep Injection Valves Model 3725 (PEEK) Model 3725i (PEEK) Model (SS) Model 3725i-038 (SS) Accessory Port Adaptor for 1/16" tubing Rheodyne Matrx Motorized Switching Valves DESCRIPTON PART NUMBER PRICE Stainles Steel Valves Analytical 6-Port Analytical 10-Port Nano 6-Port Nano 10-Port PEEK Valves Analytical 6-Port Analytical 10-Port Nano 6-Port Nano 10-Port

72 Rheodyne Switching Valves Rheodyne Manual Switching Valves Available in 6-Port and 10-Port Two-Position and Six-Position Versions Low Volume Flow Passages 5,000psig (500bar) Rating* Wide-bore Version for Prep Rheodyne Manual Switching Valve Schematics 7000 Switching Valve: Two Column Selector Injector 7000 Switching Valve: Pre-Column Backflushing Analytical Column Injector Pre Column Detector Detector Off line column is sealed. Flow continues on line. Flow continues through column. Only pre-column is backflushed Way Valve: Column Programming Way Valve: Column Backflushing Rheodyne HPLC Switching Valves offer an endless variety of ways to simplify switching and injecting. A flat polymer rotor with connecting flow passages bears against a stator under spring pressure sufficient to hold leak-tight at 7,000psig. Standard valves are supplied with 0.024" internal flow passages and are suitable for use with analytical and semi-preparative applications. Large bore valves with 0.040" internal flow passages are available for use at high flowrates (greater than 50mL/min). A spring detent mechanism included in the 6-position selection valve permits full circle rotation in either direction and ensures that the rotor falls into each of the six positions at the precise 60 spacing. *5000psig pressure rating for 2-position 6-Port and 10-port. Rheodyne Manual Switching Valves 2-position, 6-port Valve Standard 2-position, 6-port Valve is Large Bore 3-Way Valve Standard 3-Way Valve Large Bore 7000RV 7000L 7030RV 7030L 2-Position 10-Port, 4-Way Valve Standard 7040RV 2-Position 10-Port, 4-Way Valve Large Bore 7040L 5619 Column B 6 Part of sample is analyzed on columns A-B, the other part on columns A-C. Detector Column A Detector Detector 3 Injector Mobile phase flow is backflushed to direct peak of interest detector Position Selection Valve: Tandem Five Column Selection Injector 1 Column C Injector 0800 Rheodyne Selection Valve 6-Position 6-Port Valve Standard 6-Position 6-Port Valve Large Bore 7060RV 7060L Rheodyne 2-Position 10-Port Valve Standard, SS, PEEK Valve (SS) Valve (PEEK) Bypass Flush-Out Line Selects between five columns, the sixth port being reserved for a bypass/flush out line. Two 7060s are shown here

73 Rheodyne Replacement Parts 7010 Knob Assembly 8125 Handle Screw Handle Knob Set Screws (2) Shaft Needle Guide Body Thrust Bearing Spring Ring Spring Washers (4) Rotor Pin Rotor Seal Pins (4) Bearing Ring Isolation Seal Rotor Seal Stop Pins (2) Stator Ring Stator Pins (2) Stator Screws (3) Stator Seal Pins (4) Isolation Seal Body Locating Pin Pressure Adjusting Screw Body Thrust Bearing Spring Washers (4) Rotor Pin Needle Port Tube Assembly Bearing Ring Rotor Seal (Tefzel) Black Plastic Ring Stator Ring Stator Locating Pin Stator Face Assembly Stator Stator Screws (3) Stator Screws (3) /7725i Handle Set Screws (2) Body Locating Pin Needle Port Tube Assembly Isolation Seal Stator Face Assembly Handle Assembly Needle Guide Shaft Assembly Pressure Adjusting Screw Body Thrust Bearing Spring Washers (4) Position Sensing Switch (Model 7725i only) 60 Stop Ring Bearing Ring Rotor Seal Stator Ring Stator Locating Pin Stator Stator Screws (3) 7125 Knob Assembly Set Screws (2) Needle Guide Spring Washers (4) Needle Port Tube Assembly Isolation Seal Shaft Assembly Body Thrust Bearing Rotor Pin Seal Pins (4) Bearing Ring Rotor Seal (Vespel) Stop Pins (2) Stator Ring Stator Face Assembly Stator Set Screws (3) Stator Stator Screws Replacement Parts for Rheodyne Injectors DESCRIPTION QTY PART NO. PRICE Isolation Seal for All Valves Ea Stator Screw for Stator Set Screw for Stator Pin 1/16" x 5/16" Seal Pin 1/16" x 1/4" Stop Pin 3/32" x 1/2" Rotor Seal for 7010 Ea Stator for 7010/7125 Ea Stator for 7060 Ea Set Screw for Knob Needle Guide for 7125/7725/7725i/ Ea /9125 Knob Assembly for 7125 Ea Rotor Seal for 7125/7126/7725/7725i Ea PEEK Rotor Seal for 9010 Ea Tefzel Rotor Seal for 9010 Ea Replacement Parts for Rheodyne Injectors (continued) DESCRIPTION QTY PART NO. PRICE Stator Face Assembly for 7125 Ea Rotor Seal for 7410 Ea Rotor Seal for 7413 Ea Handle Assembly for 7725/7725i Ea Stator for 7725/7725i Ea Stator Face Assembly for 7725/7725i Ea Stator for 8125 Ea Rotor Seal (Vespel) for 8125 Ea Stator Face Assembly for 8125 Ea Body for 7725/7725i/8125/9125 Ea Stator Face Assembly for 9125 Ea Stator Support Ring for 9125 Ea Stator Screw for 9125 Ea Stator for 9125 Ea * Tefzel Rotor Seal for 9125 Ea PEEK Rotor Seal for 9125 Ea Tefzel Rotor Seal for 9010 Ea * Includes Ring 524

74 Rheodyne Accessories Rheodyne RheBuild Kits for Injection Valves Complete Convenient Economical RheBuild Kits are a complete selection of all the parts you need for general valve maintenance. All are genuine Rheodyne parts selected for your specific valve Rheodyne Model 7012 Loop Filler This is an accessory which minimizes the waste of sample liquid in loading the sample loop. The Loop Filler Port has a needle insertion port with very small dead volume. An adjustable Teflon seal accommodates needles ranging from 0.018" to 0.028" diameter. Conventional microliter syringes with 2" long needles can be used; they need not be highpressure syringes. A length of 0.012" ID stainless steel tubing connects the needle port to the valve sample leading port. When the loop filling lines are first dried by a gas stream, the sample wastage is about 10 microliters. Half of this is left in the link from the syringe port to valve, and half of this is wasted in the outlet line from the loop. This insures that the loop is completely filled. Applications requiring zero sample loss should use the Rheodyne 5622 Model 7125, 8125 or 9125 sample injectors. Kits for Front-Loading Injection Valves Kits for Standard Front-loading Injection Valves contain: Standard Rotor Seal, Stator Face Assembly, Isolation Seal, Needle Guide, Needle Port Cleaner, Hex Keys (2) and Instructions. Kits for Models 7520 and 7526 contain: Inlet Stator, Rotor, Needle Guide, Needle Port Cleaner, Hex Key, Rotor Removal Tool and Instructions. Kits for Rear-Loading Injection Valves Kits for Rear-Loading Injection Valves contain: Standard Rotor Seal, Isolation Seal, Hex Keys (2), and Instructions. Rheodyne RheBuild Kits KITS FOR MODELS: PART NO. PRICE Front-Loading Valves 3725, 3725i, , 3725i , , 7725i, , , , 9725i, , Rear-Loading Valves 7010, , 9040 LabPRO Valves Rheodyne High Pressure Valve Repair Alltech offers rapid, economical repair service on all Rheodyne high pressure valves. To take advantage of this service, send the defective valve with a repair purchase order to Alltech s Deerfield office. Be sure to include a detailed description of the problem and the name and phone number of the person Alltech should contact for additional information. Rheodyne Valve Repair Service Rheodyne Model 7012 Loop Filler Loop Filler Port (SS) 7044 Loop Filler Port (PEEK) Needle Port Fitting Rheodyne Valve Mounting Panels Two valve mounting accessories are available. They are aluminum plates which are drilled with the appropriate holes for attaching all Rheodyne high pressure valves. A hole is included for 5623 the Model 7012 Loop Filler Port. Model 7160 is a 1.6 x 5.1" (4 x 13cm) general purpose panel with valve mounting holes at one end and panel mounting holes at the other. The is a 2.5 x 2.5 x 2-3/8" (6.4 x 6.4 x 5.9cm) angled mounting panel which will also fit Altex/Beckman Instruments. Rheodyne Valve Mounting Panels Mounting Panel, General 7160RV Angle Mounting Bracket, General Alltech Ring Stand Brackets for HPLC Valves These sturdy brackets allow HPLC valves to be securely mounted to standard laboratory ring stands. The dimensions for the mounting bracket are 1.5 x 2.5 x 4.5" (3.8 x 11.4cm). Alltech Ring Stand Brackets for HPLC Valves 5624 Rheodyne Valve Repair Service Mounting Bracket for Valco Valves 9540 and Rheodyne Valves 525

75 Rheodyne Accessories Rheodyne ChromTRAC System Makes Fluid Line Identification Easy Rheodyne RheFlex Fittings Allows Hex-head Fittings to be Finger-Tightened Available in Five Colors A B C D Color code your HPLC fluid connections with Rheodyne's ChromTRAC knobs. These removable, brightly colored knobs fit tightly atop hex-head one-piece and hex-head two-piece fittings made by Rheodyne and Alltech. With the ChromTRAC knob installed, a wrench-tight hex-head fitting becomes a color-coded finger-tight fitting. ChromTRAC colors include blue, grey, green, red, white, yellow and black. ChromTRAC is particularly useful for color coding multi-connection systems such as those using Rheodyne 's LabPRO Column Selector, Ten-Position Selector or Solvent Selector, but they can also be used anywhere in an HPLC system where easy identification of fluid lines is desired. ChromTRAC is available in a fittings identification kit or may be ordered installed on Rheodyne Rheflex fittings (see price block). ChromTRAC is compatible with Rheodyne RheFlex One-Piece and Two-Piece fittings, Alltech One-Piece Hex-Head, Alltech No-Slip Hex-Head, and Alltech Double Sided Ferrule (DSF) fittings. ChromTRAC ID Kit DESCRIPTION QTY PART NO. PRICE ID Kit* 20/pkg *4 each of blue, red, yellow; 2 each of grey, green, white, black E H Rheodyne RheFlex Fittings GRAPHIC DESCRIPTION QTY PART NO. PRICE RheFlex Stainless Steel Fittings with Ferrules A Bushing B Long Bushing C Extra Long Bushing D Ferrules RheFlex Fittings (PEEK) with Ferrules E RheFlex Fitting F Short RheFlex Fitting G Ferrules RheFlex One-Piece (PEEK) Fingertights H RheFlex Fitting RheFlex Titanium Fittings A Bushing Ea B Long Titanium Bushing Ea D Titanium Ferrule Ea F G 0808, Rheodyne Rheflex PEEK Fittings with ChromTRAC COLOR QTY PART NO. PRICE RheFlex One-Piece Blue Grey White Green Red Yellow Multicolor* Rheodyne Position Sensing Switches Rheodyne position sensing switches can be attached to manual and automatic valves to indicate their state. The switches can signal an integrator to start, mark the injection time on a recorder, or keep a microprocessor informed of valve position. Rheodyne Position Sensing Switches RheFlex Two-Piece Standard Blue Grey White Green Red Yellow Black Rheodyne Valve Position Sensing Switch Models 7010, 7410, 7413 and All Type 70 Valves Model 7125 Valves Model 7520 Valves Model 8125 Valves Models 7725i, and 9125i Valves RheFlex Two-Piece Extra-Long Grey White Green Red Yellow Black *Includes 2 each of blue, grey, green, red, yellow. 526

76 Rheodyne Sample Loops Rheodyne Sample Loops Stainless Steel, Titanium, and PEEK For Use with Various Injection Valves PEEK Sample Loops 5640 Unlike metals, plastics are viscoelastic and therefore the yield strengths are not well defined. Many factors may affect the burst pressure of PEEK tubing. Table 1 shows the pressure at which various tubes burst during a three-week test while exposed to different solvents at room temperature. WARNING: The pressures shown are the failure level for the tubes. Routine operation should be well below these values, allowing a significant safety margin. Stainless Steel and Titanium Sample Loops Metal sample loops are supplied with unswaged fittings so they can be completely bottomed in the injector port before the ferrule is swaged on. Size designations of the metal loops are nominal. Actual volumes can differ due to the tolerances of the tubing. Precise volumes may be injected by the partial-filling method if you are using a dual-mode injector. Note: Loops for the 7725 and 7125 injectors are NOT interchangeable. Rheodyne PEEK Sample Loops Metal-Free (PEEK) Loops (with Fittings and Ferrules) For Rheodyne 9000 Series Injectors (Including 9725) 5µL µL µL µL µL µL µL mL mL mL /8" Fittings and Ferrules For Model 3725 Preparative Injectors 2mL mL mL mL Rheodyne Stainless Steel Sample Loops Stainless Steel Loops (with Fittings and Ferrules) For Model 7725/7725i Injectors 2µL (Internal) µL µL µL µL µL µL µL mL mL mL For Model 7125, 7126, 7010 Injectors 5µL 70-20SL 10µL 70-21SL 20µL 70-22SL 50µL 70-23SL 100µL 70-24SL 200µL 70-25SL 500µL 70-26SL 1.0mL 70-27SL 2.0mL 70-28SL 5.0mL 70-29SL For Model 8125/8126 Injectors 5µL µL µL µL µL µL µL mL mL mL Titanium Loops (with Fittings and Ferrules) DESCRIPTION PART NO. PRIC For Model 7010 and 7125 Titanium Injectors 10µL µL µL µL µL µL Stainless Steel Loops (with 1/8" Fittings and Ferrules) For Models Preparative Injectors, 1/8" Fitting & Ferrule 2mL mL mL Table 1 - Pressures (psig) at which PEEK Tubing Failed in a Three-week Exposure Test TUBE O.D. TUBE I.D. SAMPLE LOOP WATER 1:1 ACN/WATER 100% ACN 100% THF 100% IPA 1/16".007" 5µL >5500 > >5000 1/16".010" 10, 20-µL /16".020" 50, 100, 200-µL /16".030" 0.5, 1, 2, 5, 10-µL /8".062" 2, 5-mL /8".080" 10, 20-mL >

77 Alltech Sample Loops Alltech PEEK Flex-Connect Sample Loops Flexible Coil Bends into Place Quickly and Easily Universal Fittings Prevent Dead Volume 100% PEEK Construction Prevents Corrosion and Sample Loss Flex-Connect Sample Loops from Alltech are the most convenient sample loops to use with your Rheodyne or Beckman injection valve. A proprietary process forms the tubing into a resilient spring with straight leg portions for connection to the valve. The loop coil expands and contracts 5643 to make alignment and installation of the loop quick and convenient. Simply flex the coil to align the tubing with the valve ports and tighten the fittings (Figure 1). Each Flex-Connect Sample Loop is supplied with Hex-Head Nuts and a special two-piece ferrule (Figure 2). This new ferrule allows you to tighten the fitting without twisting the tubing. These fittings adjust automatically to match the configuration of the mating port each time a connection is made, minimizing the potential for dead volume in the connection. Flex-Connect Sample Loops and Fittings are PEEK. Use them with virtually all HPLC solvents and buffers at pressures up to 5,000psig. Studies indicate that PEEK sample loops improve recovery precision when compared with stainless steel sample loops for certain applications LC/GC, Vol. 9 #1; LC Troubleshooting: Sample Adsorption in Liquid Chromatography Injection Valves. Alltech Stainless Steel Sample Loops Finger-Tight Fittings Require No Wrenches Automatically Adjusts to Port Dimensions Leak-Proof to 5,000psig Stainless Steel Loop, PEEK Ferrule Alltech Stainless Steel Sample Loops DESCRIPTION QTY PART NO. PRICE Stainless Steel Sample Loops (SS) 5µL Sample Loops Ea µL Sample Loops Ea µL Sample Loops Ea µL Sample Loops Ea µL Sample Loops Ea µL Sample Loops Ea Sample Loop Kit Includes 1 Ea of above Loops, PEEK Ferrules Fittings Long Male Nut (SS) Short Male Nut (SS) PEEK Ferrules Two-piece Ferrule Does Not Twist Tubing Alltech Handy-Lok Fitting Wrench Slotted Design Works Around Tubing Easy Access for Hard-to-Reach Places Suitable for All Standard 1/4" Hex-Head Fittings Ideal for Connections on Rheodyne Valves 2077 Figure Figure Alltech PEEK Flex-Connect Sample Loops DESCRIPTION QTY PART NO. PRICE PEEK Flex-Connect Sample Loops 5µL Flex-Loop Ea µL Flex-Loop Ea µL Flex-Loop Ea µL Flex-Loop Ea µL Flex-Loop Ea µL Flex-Loop Ea µL Flex-Loop Ea mL Flex-Loop Ea Alltech s Handy-Lok Fitting Wrench is a helpful addition to your LC toolbox. The slotted design fits conveniently around the connecting tubing, and grips the entire hex securely. This gives you better access to fittings in awkward or obstructed locations, such as the back of a Rheodyne valve Fittings (PEEK) Short Hex-Head Nut and Ferrule Long Hex-Head Nut and Ferrule Two-Piece Ferrule Alltech Handy-Lok Fitting Wrench Handy-Lok Fitting Wrench

78 Flow Splitters ASI Adjustable Flow Splitter Valves Ideal for LC/MS, Flow Fractionation, Pre/Post Column Flow Splitting, and Capillary Chromatography Adjustable Flow Splitter Enables Direct Real Time Control Over Split Ratio Optimization Create Split Ratios From 1:1 to 20,000:1 Low Dead Volume. 0.5µL Delay Volume on Capillary Side Easy to Use Interchangeable Fluid Resistors Create a Wide Range of Split Ratios ASI Fixed Flow Splitter Valves Easy to Use Plug and Play Device Predefined Split Ratio Eliminates Tedious Adjustments to Capillary Tubing Ideal for Post Column Flow Splitting Ultra-Low Dead Volume Delay Volume on the Capillary Side as Low as 100 nl Create Split Ratios From 1:1 to 20,000:1 Using Interchangeable Fluid Resistors Multiport Flow Splitters Available for Applications Which Require 3 to 8 Channels 6329 The flow path of the ASI Adjustable Flow Splitter contains two fluid resistors that form a parallel flow path. The low flow rate stream passes through a fixed resistor cartridge, while the high flow rate stream passes through an adjustable fluid resistor (metering valve). The ratio of these two resistors creates the split flow ratio. Due to the rugged design, the split ratio repeatability is +/- 1% of setting, and unlike alternative splitter valves or tees, will not be affected by actions that effect input flow such as turning the pump off and on, or pressure spikes ASI Fixed Flow Splitters provide a fixed split ratio with extremely low dead volume. Delay volume on the low flow rate side is as low as 100 nanoliters, depending upon the resistor cartridge selected. The flow split ratio is not affected by changes in solvent viscosity or pressure, and is extremely stable and reproducible. Unlike conventional splitters that use long lengths of capillary tubing, the Fixed Flow Splitter uses compact fluid resistor elements, which are designed as cartridges for easy replacement. Because of the extremely low internal volume of the fluid resistors, the solvent composition in both resistors at any instant in time is the same, and therefore viscosity changes associated with gradient runs do not impact the split ratio*. The interchangeable fluid resistors are available in a wide range of values that make it possible to create split ratios from 1:1 to as high as 20,000:1. Flow range from 0.1 to 10mL/min. *Significant backpressure down stream from the splitter may affect the split ratio. Please consider when choosing your fixed splitter valve Because the Adjustable Flow Splitter incorporates a metering valve, split ratios can be changed frequently with flow changes that are stable and reproducible. This provides direct real time control over split ratio optimization. The Adjustable Flow Splitter will create split ratios that are not affected by changes in solvent viscosity or pressure. These splitters are ideal for gradient applications, and can be used for both pre-column and postcolumn flow splitting. Flow range from 0.1 to 10mL/min. ASI Adjustable Flow Splitter Valves ASI Adjustable Flow Splitter Valves Adjustable from 50:1 to 1000: Adjustable from 15:1 to 250: Adjustable from 4:1 to 100: Adjustable from 1:1 to 20: Replacement Resistor Cartridges -00 Resistor Cartridge Resistor Cartridge Resistor Cartridge Resistor Cartridge Resistor Cartridge Resistor Cartridge ASI Fixed Flow Splitter Valves ASI Fixed Flow Splitter Valves Ratio = 2000 : Ratio = 1000 : Ratio = 500 : Ratio = 200 : Ratio = 100 : Ratio = 50 : Ratio = 20 : Ratio = 10 : Ratio = 5 : Ratio = 3 : Ratio = 1 : ASI Replacment Resistor Sets Ratio = : Ratio = : Ratio = 5000 : Ratio = 2000 : Ratio = 1000 : Ratio = 500 : Ratio = 200 : Ratio = 100 : Ratio = 50 : Ratio = 20 : Ratio = 10 : Ratio = 5 : Ratio = 3 : Ratio = 1 :

79 Low Pressure Valves Hamilton Miniature Inert Valves Inert Teflon and Kel-F Flowpath 1/4-28 UNF Port Connections Available in Standard or Panel Mount Configurations Maximum Pressure 100psig Temperature Range 10 C to 100 C Looking for a way to conveniently select solvents or fluid flow paths? Hamilton HV Plug Valves provide an economical and flexible method of custom-building a fluid flow control system, from a simple on/off valve to a more complex multi-valve arrangement. The small valve body with its chemically inert flow path is ideally suited for low pressure applications. All HV Plug Valves allow you to select and interchange a wide variety of fittings, adapters and tubing, including male and female luers, FEP tubing assemblies, and adapters which thread directly into the valve providing an endless variety of valve configurations for any flow application. Hamilton HV fittings and adapters are installed finger-tight and provide a leak-tight seal tested to 100 psig. Three body styles of valves are available: HV Valve HVP Valve HVX Valve A B C D 5601 HV - stand alone manual valve, ideal for low pressure applications HVP - panel-mountable manual valve, ideal for low pressure applications. E F G H HVX - panel-mountable manual valve, larger internal port diameter, ideal for higher fluid flows or viscous fluids. Hamilton Plug Types 90, 180, T and 4-Port: Flowpath Connects 2 or More Side Ports Distribution: Flow Path Connects Bottom Port to Any One Side Port I J K 5609 L 5610 Injection: Flow Path Connects Pairs of Adjacent Side Ports M N O P Hamilton Miniature Inert Valves DRAWING HOUSING PLUG HV HV HVP HVP HVX HVX NUMBER TYPE TYPE** PART NO. PRICE PART NO. PRICE PART NO. PRICE A * B * C T T * D T * E 4-Port 4-Port * F 4-Port T * G 4-Port * H 4-Port * I 180 Distribution * J 90 Distribution * K T Distribution * L 4-Port Distribution * M 6-Port Distribution N 6-Port Injection O 8-Port Distribution P 8-Port Injection * HVP Valves require locking nut (Part No ) for panel mounting. HVX Valves require locking nut (Part No ) for panel mounting. 530

80 Low Pressure Valves Hamilton Miniature Inert Valve Accessories A D Hamilton CTFE Valve Terminal Fitting GRAPHIC A CTFE Barbed Fitting B CTFE Male Luer Connector C CTFE Female Luer Connector D CTFE Luer Lock Connector E CTFE Bushing for RN Needles B E C Rheodyne Low Pressure Switching Valves Chemically Inert Zero-Dead Volume Operate Up To 300psig 0.8 or 1.5mm Bore Manual or Automatic Low Cost Rheodyne low pressure switching valves represent a new generation of chemically inert switching valves. Designed with flow passages of 0.8 or 1.5mm and no mixing cavities, the valves allow the sample to contact only Teflon and Kel-F. External parts are constructed of Teflon and stainless steel. The maximum operating temperature is 50 C and the maximum allowable pressure is 300psig. The valves are operated by a 60 degree rotation of a flat rotor bearing against a flat stator. Teflon tubes are connected with conventional 1/4-28 TPI tube end fittings. Positive stops are used in the 2-position (injector) models and spring detents are provided on the 6-position (stream selection) valves (Part No.'s & 50120) to assure perfect alignment. The 6-port sample injection valve functions in a similar manner to higher priced high-pressure valves. All valves can be autoclaved at 120 C after loosening spring tension Hamilton Handles Handle 180 Flow Path Flow Path T Path Port Path Port Distribution Path Panel Mount Nut for Panel Mount Valves Configured in drawing A-L for Panel Mount Valves Configured in drawing M-P Rheodyne Low Pressure Switching Valves DESCRIPTION BORE SIZE PART NO. PRICE Type 50 Teflon Switching Valves 3-Way, 0.8mm Way, 1.5mm Way, 0.8mm Way, 1.5mm Port Stream Selector, 0.8mm Port Stream Selector, 1.5mm Port Injection Valve, 0.8mm (with 0.5mL Sample Loop and Luer Connector) Sample Loops, Teflon 0.1mL mL mL mL mL mL Accessories Type 50 Mounting Bracket

81 SSI Valves SSI High-Pressure Needle Valves Connections with 1/16" SSI Fittings Rated for Use to 15,000psig Available in 2-Way and 3-Way Configurations SSI Two-Way Valve 15,000psig Pressure Limit Basic shut-off valve available in straight through (A) or angled (B) designs. SSI Prime/Purge Valve with Luer Stem Luer Port in Stem Opens for Priming, Closes for Normal Use High-Pressure Connections with 1/16" SSI Fittings Available in 316 Grade Stainless Steel and PEEK Versions 6,000psig Pressure Limit F 0779 SSI Check Valves Teflon and Kalrez Seals 316 Stainless Steel Housing Gravity Assisted Poppet Eliminates the Use of Springs Opening Pressure <0.5psig Internal Volume: 121µL 6,000psig Pressure Limit A B SSI Three-Way Valve 15,000psig Pressure Limit Placed between the pump and injector, this valve allows pressure to vent for easy purging, priming, or solvent changeover. Valve opens and closes flow to port 3 while Ports 1 & 2 remain connected. The 3-Way side vent valve (graphic D) replaces bypass valves on Perkin-Elmer, Altex, Spectra-Physics, LDC and others. FLOW G Typical check valve applications include back-up to both inlet and outlet pump check valves. Used in this manner, check valves can improve flowrate precision and reduce pulsations, especially in less sophisticated, reciprocating pumps SSI 2-Way, 3-Way, Prime/Purge & Check Valves DRAWING NO Two-Way Valves A Two-Way Through Valve, 1/16" B Two-Way Angle Valve, 1/16" C 1764 SSI Standard Prime/Purge Valve Low-Pressure Side-Port Opens for Priming, Closes for Normal Use High-Pressure Connections with 1/16" SSI Fittings Side-Port Connects with 1/4-28 Flanged or Flange-Free Fittings Flow Path: Teflon, Tefzel, and 316 Grade Stainless Steel 6,000psig Pressure Limit 2 D E Three-Way Valves C Three-Way, Bottom Vent, 1/16" D Three-Way, Side Vent, 1/16" Prime/Purge Valves E Standard Prime/Purge Valve Seal Kit for F PEEK Prime/Purge Valve with Luer Stem F SS Prime/Purge Valve with Luer Stem Check Valves G Check Valve, Soft Seat, 1/16" Replacement Check Valve Seal Fittings/Ferrules 1/16" SSI Gland Nut, 10/pkg /16" Ferrule, 10/pkg

82 HPLC Syringes Hamilton 1700 Series Removable Needle Gas-Tight Syringes Hamilton 800 Series Removable Needle Syringes For Rheodyne, Beckman, and Valco (VISF-2) Injection Valves These syringes have an inert, gas-tight flow path made of borosilicate glass barrels and Teflon plunger tips. Removable needles may be replaced when bent or clogged For Waters Injection Valves 800 Series syringes have borosilicate glass barrels, precision-fitted stainless steel plungers, and extended metal handles. These syringes have removable needles to fit Waters injection valves Series Syringes 800 Series Syringes DESCRIPTION QTY PART NO. PRICE For Rheodyne, Beckman, and Valco (VISF-2) Injectors 10µL 1701RNR Syringe Ea µL 1702RNR Syringe Ea µL 1705RNR Syringe Ea µL 1710RNR Syringe Ea DESCRIPTION QTY PART NO. PRICE For Waters injectors 10µL 801RNW Syringe Ea µL 802RNW Syringe Ea µL 805RNW Syringe Ea µL 810RNW Syringe Ea Spare Needles for Removable Needle Syringes For Syringes with Volumes from 2.5µL-100µL Spare Needles for Removable Needle Syringes For Syringes with Volumes from 5µL to 100µL Hamilton 700 Series Fixed-Needle Syringes For Rheodyne, Beckman, and Valco (VISF-2) Injection Valves Hamilton 1000 Series Priming Syringe For Waters Pumps 700 Series Fixed-Needle Syringes For Rheodyne, Beckman, and Valco (VISF-2) Injectors 10µL 701SNR Syringe µL 702SNR Syringe µL 705SNR Syringe µL 710SNR Syringe µL 725SNR Syringe µL 750SNR Syringe Hamilton 600 Series Small Volume Removable Needle Syringes For Rheodyne, Beckman, and Valco (VISF-2) Injection Valves 600 Series Syringes DESCRIPTION QTY PART NO. PRICE For Rheodyne, Beckman, and Valco (VISF-2) Injectors 2.5µL 62RNR Syringe Ea µL 65RNR Syringe Ea Spare Needles for Removable Needle Syringes For Syringes with Volumes from 2.5µL-100µL 4801 This 10mL Syringe is used for priming Waters pumps Series Priming Syringe 10mL 1010W Gas Tight Priming Syringe Draw Needles for Waters Pump Disposable Plastic Syringes with Luer Tips Use these economical syringes for injection of aqueous samples, for priming pumps, and other applications where polypropylene and silicone rubber wetted surfaces are acceptable. Disposable, singleuse syringes eliminate cross contamination. A luer-hub needle (Part No ) connects these syringes to Rheodyne, Beckman, or Valco (VISF-2) injection valves. Disposable Plastic Syringes DESCRIPTION QTY PART NO. PRICE 1mL Plastic Syringe mL Plastic Syringe mL Plastic Syringe CTFE Luer-Hub Needle for Rheodyne, Beckman and Valco (VISF-2) Injection Valves

83 Organizers and Test Mixtures Organize Your HPLC Columns and Accessories Store your favorite LC supplies in this handy organizer. The portable unit holds up to 10 HPLC columns, tools, log book and fittings for quick access. Nine flexible storage compartments have room for fittings, guard columns, tubing, pens, 5507 ferrules, log books and more. There is even a built-in wipe-dispenser. Construction is chemically-resistant expanded PVC. Small footprint design - 12"H x 24"W x 6"D. HPLC Supplies Organizer HPLC Supplies Organizer 5238 Organize and Protect Your HPLC Columns Store and protect up to 30 HPLC columns for instant identification and access. This column storage unit mounts on a wall with screws (included). Two secure rows of 15 columns may be stored behind acrylic doors, allowing easy viewing of columns on hand. Construction is chemically-resistant expanded PVC (wall unit) and acrylic (doors). 17 3/8"H x 15"W x 2 7/8"D Reversed-Phase Test Mix-D4 The Reversed-Phase Test Mix-D4 is a four component mixture designed to measure the efficiency, capacity, selectivity, and symmetry of reversed-phase columns. The mixture is easily separated by most reversed-phase columns (C18 and C8) using an organic/aqueous mobile phase. Use toluene to measure column efficiency, and phenol or N,N-diethyl-m-toluamide to assess peak symmetry (tailing). Uracil is a void volume marker. Reversed-Phase Test Mix-D4 COMPONENT CONCENTRATION 1. Uracil 0.015mg/mL 2. Phenol (Acid Probe) 0.7mg/mL 3. N,N-Diethyl-M-Toluamide (Base Probe) 0.6mg/mL 4. Toluene 4.0mg/mL Dissolved in Acetonitrile:Water (58:42) Reversed-Phase Test Mix-D4 Reversed-Phase Test Mix-D Normal Phase Test Mix-A6 The Normal Phase Test Mix-A6 is a three component mixture designed to measure the efficiency, capacity, selectivity, and symmetry of amino, cyano, diol, or silica (unbonded) packings. The mixture is easily separated using an ethanol/hexane mobile phase. Efficiency and peak symmetry can be assessed using either of the phthalate peaks. Normal Phase Test Mix-A6 COMPONENT CONCENTRATION 1. Toluene: 1.0mg/mL 2. Diethyl Phthalate: 1.0mg/mL 3. Dimethyl Phthalate: 1.0mg/mL Dissolved in Ethanol:Hexane (5:95) HPLC Column Storage Unit HPLC Column Storage Unit 5240 Normal Phase Test Mix-A6 Normal Phase Test Mix-A6, 1mL 1096 Organize Your Laboratory Accessories Plastic Box with Removable Dividers Gain valuable benchtop space with this extra-large supply bin with adjustable dividers. Arrange the dividers to create the bin size you want. Made of chemically-resistant PVC plastic, the unit offers up to 14 bin spaces and two storage shelves. 20"H x 24"W x 10.5"D 5509 This Plastic Box has a hinged lid and 13 removable dividers. It is ideal for orgainzing small pieces, such as fittings and borecut tubing Lab Storage Bin Unit Plastic Box with Removable Dividers Lab Storage Bin Unit 5242 Plastic Storage Box

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New! Inlet Solvent Filters Filters and Degassers General Use Inlet Solvent Filters Large Surface Areas disposable µm, 0 µm, and 0 µm Pore Sizes Available General Use and Prep Filters for Higher Flow Applications

More information

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Deburring an Upchurch Scientific fitting in Oak Harbor, WA. The Very High Pressure (VHP) reusable fitting, VHP-320, is one of the exciting new products in the

More information

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings. Fingertight Fittings 4 One-Piece Fingertight Fittings Upchurch Scientific s original One-Piece Fingertight Fittings have 0-3 threads and are designed to be used with /6 OD tubing, except the M-645 (6-40,

More information

Instrument Accessories & Parts, Tubing & Connections

Instrument Accessories & Parts, Tubing & Connections Instrument Accessories & Parts, Tubing & Connections ASI Piston Seals for Agilent HPLC Systems Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed

More information

Upchurch High Pressure Fittings & Connectors

Upchurch High Pressure Fittings & Connectors .010 thru-hole P-742 PEEK ZDV Union. 9 2.050 thru-hole P-760 PEEK ZDV Union P-704 PEEK ZDV Union. 9 2. 9 2 Fingertight Fittings ONE-PIECE FINGERTIGHT FITTINGS INTRODUCTION For Coned Ports For convenience

More information

Connectors & Connectors with valves

Connectors & Connectors with valves Connectors & Connectors with valves Inside... Omnifit Cap instructions... Small Bore Connectors... 3 with valves... Large Bore Connectors... 5 with valves... 5 T Block Connector... 6 In-line Connectors...

More information

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 156 Inlet Solvent

More information

Mobile Phase Management

Mobile Phase Management hplc columns & accessories hplc accessories Mobile Phase Management The solvent filtration apparatus rapidly filters and degasses HPLC and IC mobile phases. Description Part No. 1L Flask, 300mL Funnel,

More information

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C C OMPONENT S F O R A C L O S E D - S YS T E M HPL C TM Western Analytical Products, Inc hplc and gc columns and accessories fittings, tubing, valves, frits and filters lab and industrial safety products

More information

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations. Simplify your search for COLUMN HARDWARE Discover how to maximize results with Isolation Technologies column hardware and accessories that are specifically engineered to meet critical UHPLC, HPLC, and

More information

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913 GLENCO Syringes As a complement to the Spectra/Chrom chromatographic products, Spectrum manufactures precision syringes for sample injection and collection. These syringes are designed specifically to

More information

FITTINGS, LOOPS, AND VALVE ACCESSORIES

FITTINGS, LOOPS, AND VALVE ACCESSORIES FITTINGS, LOOPS, AND VALVE ACCESSORIES Fittings Rheodyne offers a variety of fittings. They differ in material of construction, tubing size, and pressure rating. Materials/Biocompatibility. 316 stainless

More information

Glass Columns for Laboratory and Pilot Scale Liquid Chromatography

Glass Columns for Laboratory and Pilot Scale Liquid Chromatography Glass Columns for Laboratory and Pilot Scale Liquid Chromatography 1 Content 1. ECO PLUS Glass Columns...3 1.1 Highlights...3 1.2 Characteristics...3 1.3 Available Versions...4 1.4 Ordering Information...4

More information

Fitting Systems. Leak-free, ee, simple-to-use 1/4-28 and M6 fitting types in

Fitting Systems. Leak-free, ee, simple-to-use 1/4-28 and M6 fitting types in Fitting Systems Inside... Gripper Fitting System... 2 Assembling...2 Ordering...3 Flanged Fitting System... 4 Ordering...4 Inverted Cone Fitting System... 5 Ordering...5 Omnigrip Fitting System...6 Ordering...6

More information

Ultra High Performance Fittings. Fittings Connectors Kits

Ultra High Performance Fittings. Fittings Connectors Kits Ultra High Performance Fittings Fittings Connectors Kits Ultra High Performance Fittings Introduction Ultra Performance Fittings Introduction high Temperature Versions Withstand Temperatures up to 200ºC

More information

IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 Filters & Frits Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

More information

(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 .

(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 . Low Pressure FITTINGS & CONNECTORS Dimensions for /4-8 Upchurch Scientific eliminate the need to flange. This removable and reusable system provides several benefits: (pages 58 and 59) Convenience: Our

More information

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet 1. Description The Agilent Dynamax modular HPLC column system uses a unique technology, Dynamic, to maintain the structure of the packed

More information

Quick Reference Guide. Supplies for Waters HPLC Systems

Quick Reference Guide. Supplies for Waters HPLC Systems Quick Reference Guide Supplies for Waters HPLC Systems works with WATERS SHIMADZU THERMO/DIONEX BRUKER/VARIAN PERKINELMER CTC MORE Put innovation and quality to work on a wide range of GCs and HPLCs in

More information

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO 8 SupelPRO Valves Order:.800..00 Technical Service:.800.9.0 Web: www.sigma-aldrich.com/supelco SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled,

More information

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION Waters Advanced Purification (AP) series of glass columns are constructed of biocompatible glass and polymeric materials and can be easily used with

More information

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271 Restek Replacement Parts for Agilent HPLC Systems Meet or exceed OEM performance. Agilent part # qty. cat.# price Preventive Maintenance Kit Includes: rotor seal, needle seat, needle assembly, seat cap

More information

FLUIDICS FITTINGS. 32 CONED FITTINGS 39 FLAT-BOTTOM FITTINGS 48 MarvelX 50 FITTINGS TOOLS 56 LARGE BORE FITTINGS 57 VHP FITTINGS 61 FITTINGS KITS

FLUIDICS FITTINGS. 32 CONED FITTINGS 39 FLAT-BOTTOM FITTINGS 48 MarvelX 50 FITTINGS TOOLS 56 LARGE BORE FITTINGS 57 VHP FITTINGS 61 FITTINGS KITS 30 FITTINGS We offer a wide and diverse selection of fittings to meet your system requirements. A fitting refers to a complete product ready to assemble and connect tubing into a part. This could be a

More information

HPLC Tubing and Fittings Hints & Tips for the Chromatographer

HPLC Tubing and Fittings Hints & Tips for the Chromatographer HPLC Tubing and Fittings Hints & Tips for the Chromatographer By William S. Letter (Chiralizer Services, L.L.C.) INTRODUCTION: Setting up a high pressure liquid chromatography (HPLC) system to run trouble-free

More information

14 Chromatography Columns

14 Chromatography Columns 14 Chromatography Columns LC Columns Selection Guide Omnifit Labware columns offer the maximum performance for low to mid pressure liquid chromatography or flow chemistry applications. Simple to assemble,

More information

This convenient system is made entirely of inert parts: glass, Baseline drift

This convenient system is made entirely of inert parts: glass, Baseline drift 95 P000515 55020 9960342 Supelco Mobile Phase Degassing System 55060-U Eliminates: Flow instabilities Mobile Phase Reservoir System Detector noise This convenient system is made entirely of inert parts:

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

OMNI-LOK TYPE S Chemically inert flangeless fitting with permanently attached PEEK or ETFE ferrules.

OMNI-LOK TYPE S Chemically inert flangeless fitting with permanently attached PEEK or ETFE ferrules. Fitting Systems 2 Index Page 4 Page 6 Page 8 Page 10 Page 12 Page 14 Page 15 Page 16 Page 17 OMNI-LOK TYPE P Chemically inert flangeless fitting with permanently attached PTFE ferrule. Ideal for repeat

More information

*Order ferrules separately. Outlet Splitter. Outlet Splitter 14898

*Order ferrules separately. Outlet Splitter. Outlet Splitter 14898 Capillary Connectors Universal Capillary Connectors One size fits tubing from 0.25mm i.d. to 0.53mm i.d. Available in straight or Y configurations Capillary connectors form a gas-tight seal when heated

More information

Polymeric Fittings Low Pressure

Polymeric Fittings Low Pressure INDEX PPS Nuts for Flat Bottom Fitting Details 59 PEEK Flangeless Nuts 62 Polyacetal Color Coded Flangeless Nuts 63 Polypropylene Flanged Fingertight Nuts 64 Unions 65 Bulkhead Unions 67 PEEK Tees, Crosses

More information

FILTERS & COLUMN ACCESSORIES

FILTERS & COLUMN ACCESSORIES 156 FILTERS & COLUMN ACCESSORIES INLET SOLVENT FILTERS PAGE 157 INLINE SOLVENT FILTERS PAGE 160 PRECOLUMN FILTERS PAGE 163 FRITS PAGE 165 GUARD COLUMNS PAGE 170 SEE STARRED PRODUCTS FOR TOP SELLERS! Inlet

More information

Solvent Safety Bottle Caps

Solvent Safety Bottle Caps Solvent Safety Bottle Caps 2 Index Page 4 Page 6 Q-SERIES BOTTLE CAPS 1/4-28 UNF ports with optional on-off valves. A screw-in check valve and filter is available for a completely closed solvent supply

More information

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching High Pressure Valves MX Series II Modules Manual Sample Injection Introduction to High Pressure Valves HIGH Pressure Valves High Pressure Valves Introduction Rheodyne valves fit virtually any flow control

More information

Index Page 4. Page 6. Page 8. Page 10. Page 12. Page 14. Page 15. Page 16. Page 17. Page 18. Page 20.

Index Page 4. Page 6. Page 8. Page 10. Page 12. Page 14. Page 15. Page 16. Page 17. Page 18. Page 20. Fitting Systems 2 Index Page 4 Page 6 Page 8 Page 10 Page 12 Page 14 Page 15 Page 16 Page 17 OMNI-LOK TYPE P tting with permanently attached PTFE ferrule. Ideal for repeat connect/disconnect. Our highest

More information

cheminert fittings Low Pressure Flangeless Tube End Fittings Flangeless tube end fittings 1/4-28

cheminert fittings Low Pressure Flangeless Tube End Fittings Flangeless tube end fittings 1/4-28 Low Pressure Flangeless Tube End Fittings Cheminert low pressure fittings are ideally suited for flow injection analysis, low pressure liquid chromatography, and stream sampling devices. They may be safely

More information

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers HyperShear TM HPLC and UHPLC s Reduce baseline noise, increase sensitivity and improve gradient accuracy Decrease mixing and delay volume without sacrificing mixing efficiency Increase reaction efficiency

More information

Prep Flash TLC. Preparative Chromatography

Prep Flash TLC. Preparative Chromatography Prep Flash TLC Preparative Chromatography........ 148 183 Introduction...................... 148 151 Columns....................... 152 171 GraceAlpha Columns 152 155 Vydac MS Columns 156 157 Vydac TP

More information

Jour. Chromatography Fluid/Gas Transfer. Jour. CATALOG 20 INT. VICI Jour Chromatography Fluid/Gas Transfer

Jour. Chromatography Fluid/Gas Transfer. Jour.   CATALOG 20 INT. VICI Jour Chromatography Fluid/Gas Transfer www.vici-jour.com VICI Jour Chromatography Fluid/Gas Transfer Jour Chromatography Fluid/Gas Transfer Jour VICI AG International Parkstrasse 2 6214 Schenkon Switzerland Phone +41 41 925 62 00 Fax +41 41

More information

Tubing Cutter for 1/16" Stainless Steel Tubing

Tubing Cutter for 1/16 Stainless Steel Tubing Delivery Tubing and ccessories 311 P000257 Tubing Cutter for 1/16" Stainless Steel Tubing 58692-U Low-cost tool cuts 1/16" stainless steel tubing without obstructing the bore. Easily cut 1/16" OD stainless

More information

VERITY Purification Systems Build the perfect system to fit your research

VERITY Purification Systems Build the perfect system to fit your research VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC

More information

ECO Series Glass Columns

ECO Series Glass Columns ECO Series Glass Columns 2 General Features Biocompatible Solvent resistant version (optional) Easy to use Low temperature application 2 adjustable length plungers supplied on request Compatible with any

More information

Sample Pretreatment, Accessories

Sample Pretreatment, Accessories 11 Sample Pretreatment, Accessories Sample pretreatment -------------------------- 144 Column protection----------------------- 145~147 Tubing parts ------------------------------ 148~151 Empty columns

More information

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories Copyright 2004 Alltech Associates, Inc.UNP brochure #487K accessories GC Organizers 5-Column Storage Unit Plastic Storage Box 10-Column Storage Unit Utility Cabinet Lab Storage Bin Unit GC Organizers

More information

Mobile Phase Accessories

Mobile Phase Accessories NEW! Now available for GL-45 bottles! Bottles not included Waste Overflow Indicator Avoid messy pooling around mobile phase waste containers. Audible alarm instantly alerts user, preventing overflow. Compact,

More information

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems HPLC Essentials Genuine Replacement Parts for HPLC Systems 20 YEARS Turning Visions into Reality 800-356-1688 814-353-1300 2 Becky Wittrig HPLC Products Marketing Manager 4+ years of service! did you know?

More information

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter HPLC ACCESSORIES IDEX Injection Valves IDEX Injection Valves Manual IDEX MANUAL INJECTION VALVES DESCRIPTION POS. SENSING SWITCH MAX PSI FITTING HIGH PRESSURE, ANALYTICAL (accepts a 22 gauge needle) FITS

More information

HIGH PRESSURE SWITCHING VALVES

HIGH PRESSURE SWITCHING VALVES HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available

More information

Innovative HPLC, UHPLC & LC/MS products

Innovative HPLC, UHPLC & LC/MS products Innovative HPLC, UHPLC & LC/MS products Innovative HPLC, UHPLC & LC/MS products Optimize Technologies is dedicated to providing the highest quality HPLC, UHPLC and LC/MS products available. We combine

More information

A.I.T FRANCE VICI ACCESSOIRES HPLC

A.I.T FRANCE VICI ACCESSOIRES HPLC Tubes pour HPLC PEEK OD and ID, see chart 1/16 +/- 0.05 mm (.002 ) 1/8 +/- 0.10 mm (.004 ) See chart Solid Color Coding The process used in extruding this type allows the olor to permeate through the entire

More information

Fixed Flow Splitter *

Fixed Flow Splitter * Fixed Flow * *Patent Pending Analytical Scientific Instruments Fluid resistor technology eliminates tedious adjustments to capillary tubing to change split ratios. Easy to use interchangeable fluid resistors

More information

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers HyperShear TM HPLC and UHPLC s HyperShear TM HPLC and UHPLC Features: Micro Flow, Low Flow, Analytical Flow, High Flow and Combo Series Reduce baseline noise, increase sensitivity and improve gradient

More information

tubing, faucets and fittings

tubing, faucets and fittings small Bore teflon ptfe tubing Order by the Foot* Superior Chemical Resistance High degree of flexibility allows multiple twists and turns in tight spaces Non-stick surface will not collect particulates

More information

98 동방하이테크상사 T.(02) F.(02)

98 동방하이테크상사   T.(02) F.(02) 98 동방하이테크상사 http://www.allpump.co.kr T.(0)57-69 F.(0)57-69 00--7 troduction to Upchurch Scientific Valves Valves troduction Valves jection and Selection Valves for Pressures to,000 psi (69 bar) Switching

More information

Liquid Chromatography LC Consumables SSI-LC

Liquid Chromatography LC Consumables SSI-LC Liquid Chromatography LC Consumables SSI-LC-10-2017 Table of Contents HPLC Pumps...3 LC-30AD... 3 LC-20AD / LC-20AB / LC-20ADXR... 4 LC-20AT... 4 LC-20Ai... 5 LC-10ADvp... 5 LC-10ATvp... 6 LC-10Ai... 6

More information

Chromatography. Consumables and Supplies. Brownlee Cartridge and Conventional Columns! Hydrogen Generators! Portable Gas Leak Detector!

Chromatography. Consumables and Supplies. Brownlee Cartridge and Conventional Columns! Hydrogen Generators! Portable Gas Leak Detector! Chromatography Consumables and Supplies Genuine PerkinElmer Products Genuine Value VOLUME 3 2008 2009 PerkinElmer The Clear Choice in Chromatography NEW! SERIES 275 HRES LC Brownlee Cartridge and Conventional

More information

PORTAFOLIO DE CROMATOGRAFÍA LABINS

PORTAFOLIO DE CROMATOGRAFÍA LABINS PORTAFOLIO DE CROMATOGRAFÍA LABINS LABINS SAS NIT 900090654 6 Tel 57 1 4725717 Cel 57 3156342765 labins sas@outlook.com gerencia@labins.com.co www.labins.com.co Catálogos: Agilent Technologies, SGE, Separation

More information

FITTINGS VHP FITTINGS CONED FITTINGS MICRO/NANO FLAT-BOTTOM FITTINGS PAGE 6 PAGE 10 PAGE 17 PAGE 21.

FITTINGS VHP FITTINGS CONED FITTINGS MICRO/NANO FLAT-BOTTOM FITTINGS PAGE 6 PAGE 10 PAGE 17 PAGE 21. 4 FITTINGS VHP FITTINGS PAGE 6 CONED FITTINGS PAGE 10 MICRO/NANO PAGE 17 FLAT-BOTTOM FITTINGS PAGE 21 SEE STARRED PRODUCTS FOR TOP SELLERS! i INTRODUCTION How to Order How to Order Direct from IDEX Health

More information

QuickSplit TM Flow Splitters

QuickSplit TM Flow Splitters Quick TM Flow ters Quick TM Flow ter Features: Fluid resistor technology eliminates tedious adjustments to capillary tubing for split ratio optimization ratios are stable and reproducible, and not affected

More information

16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry

16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry 2 Contents Solvent Safety Bottle Caps 4 Bottle Caps Selection Guide Q-Series Solvent Bottle Caps 6 1/4"-28 UNF threaded inlet lines with optional on-off valves T-Series Solvent Bottle Caps 8 Push-through

More information

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent Valve Kit G4231A/B and G4232A/B/C Agilent Valve Kit G4231A/B and G4232A/B/C Instructions Contents Typical Applications 2 Dual column selection (G4231A/B or G4232A/B/C) 2 Sample enrichment and sample cleanup (G4231A/B or G4232A/B/C) 2 Alternating

More information

Adjustable Flow Splitter *

Adjustable Flow Splitter * Adjustable Flow Splitter * *Patent Pending Analytical Scientific Instruments Adjustable metering valve enables precise direct control over split ratios. Fluid resisr technology eliminates tedious adjustments

More information

HyperShear TM HPLC Mixers

HyperShear TM HPLC Mixers HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex shear mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume

More information

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N ) CRD 200 Product Manual Page 1 of 18 PRODUCT MANUAL FOR CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N 062983) CRD 200 (2 mm) (P/N 062986) Dionex Corporation, 2006 Document No. 065068 Revision 04 November

More information

Spring Column Hardware

Spring Column Hardware Spring Column Hardware For Use with Multipacker Packing Instruments High-efficiency axial compression packing mechanism Extend media lifetime Mobile Dynamic Axial Compression (DAC) column Easily packed

More information

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,

More information

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters ADAPTERS Whether converting joint types, reducing or enlarging joints, or creating connections in a distillation apparatus, Kimble offers a comprehensive selection of adapters including bushing adapters,

More information

HPLC BRAND MODELS PAGE NO. Beckman/Altex 100A, 110A/B, 112/112M, 114/114M, 116, 118, 125, 126, 127, 128

HPLC BRAND MODELS PAGE NO. Beckman/Altex 100A, 110A/B, 112/112M, 114/114M, 116, 118, 125, 126, 127, 128 hplc finder Find the Optimize parts you need quickly and easily! Simply locate the brand and/or model number of your HPLC system on the table below to find the catalog section you need. HPLC BRAND MODELS

More information

C L O S E D S Y S T E M S VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS

C L O S E D S Y S T E M S VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS C L O S E D S Y S T E M S F O R S O L V E N T C O N T A I N M E N T VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS I N T R O D U C T I O N C L O S E D S Y S T E M S I N T R O D U C T I O N Minimize solvent

More information

CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS

CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS INTRODUCTION CLOSED SYSTEMS INTRODUCTION Through leaks, spills, and ventilation, an open solvent-using system will

More information

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa Septa Chromatogram Cross Reference Guide Actual Size Drawing Measurement 1/4" (6mm) Shimadzu*, SRI* Chromatographs 3/8" (9.5mm) 7/16" (11mm) Antek, Finnigan 9100, 9600, Gow- Mac, Agilent 5700, 5880 & 5900,

More information

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bio science ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector

More information

CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS

CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS INTRODUCTION CLOSED SYSTEMS INTRODUCTION Through leaks, spills, and ventilation, an open solvent-using system will

More information

Agilent G5632 Valve Kit Instructions

Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Contents Typical Applications 2 Alternating Column Regeneration (2 position/10 port valves only) 2 Dual column selection 3 Sample

More information

PrimeLine TM HPLC Pumps

PrimeLine TM HPLC Pumps PrimeLine TM HPLC Pumps Isocratic Model 501 Gradient System 500G PrimeLine TM Isocratic and Gradient HPLC Pumps Feature: Self-priming pump head requires no manual priming Patented Floating Pump Seal design

More information

EGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer

EGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer EGC II K 2 Cartridge Electrolytic ph Modifier EGC Carbonate Mixer PRODUCT MANUAL FOR THE EGC II K 2 CARTRIDGE EGC II K 2 CARTRIDGE, P/N 058904 ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N 063175 EGC CARBONATE

More information

5 µm Preparative HPLC Columns

5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns Your only as good as your last product. ~ James Browne, Continuous Improvement Program Manager/Lean/6-Sigma Program Manager, Wexford, Ireland

More information

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN 80-6000-32 Physiological Calibration Standard II 80-2037-62 Calibration standard physiological fluid 80-2037-61 CALIBRATION STANDARD PROTEIN HYDROLYSATE 80-2104-53 1/8" FLANGELESS FITTING (PK 5) 80-2108-41

More information

Coflore. ACR Catalogue. AM Technology. Engineering Chemistry

Coflore. ACR Catalogue.  AM Technology. Engineering Chemistry Coflore ACR Catalogue www.amtechuk.com Company Overview is a chemical engineering company based in Cheshire, England. The company was founded in 2000 and specialises in flow chemistry. We are global leaders

More information

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test GlycoChrom TM HPLC Analyzer Hardware Installation and System Test PIN 410-5004 For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-8 00-424-6723) ,, Table of Contents

More information

Agilent G4239C Valve Kit - Instructions

Agilent G4239C Valve Kit - Instructions Agilent G4239C Valve Kit - Instructions Agilent G4239C Valve Kit - Instructions Technical Information about the Agilent Valve Kit G4239C. Contents Typical Applications 2 Multicolumn Selection 2 Method

More information

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares Competitive Comparison Maximize Performance and Minimize Maintenance with LC Spares high-quality spare parts and preventative maintenance kits Regular replacement of crucial parts can help keep your HPLC

More information

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage. 1. Overview The front panel houses the UV detector lamp switch, Rheodyne injection valve, prime/purge valve, pressure gauge, and the storage compartment. In the storage compartment are the LED display

More information

Dionex CRD Carbonate Removal Device

Dionex CRD Carbonate Removal Device Thermo Scientific Dionex CRD Carbonate Removal Device Product Manual P/N: June 2013 Part of Thermo Fisher Scientific Product Manual for Dionex CRD Carbonate Removal Device 180 CRD 180, 0.4 mm (P/N 079960)

More information

ACE. Intelligent Solutions for Method Development. Method Development Kits. ACE UHPLC and HPLC Columns

ACE. Intelligent Solutions for Method Development. Method Development Kits. ACE UHPLC and HPLC Columns Buy 1 column and get up to 2 columns FREE* *of the same particle size and column dimensions ACE Method Development Kits Intelligent Solutions for Method Development UHPLC and HPLC method development kits

More information

HyperShear TM HPLC Mixers

HyperShear TM HPLC Mixers HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex sheer mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume

More information

Universal Pipette Tips Ultra-clear and certified RNase/DNase-free

Universal Pipette Tips Ultra-clear and certified RNase/DNase-free Universal Pipette Tips Ultra-clear and certified RNase/DNase-free Universal Tips Tip Volume For Pipetter Bulk Rack 0.1-10 μl 5 - μl 0 0 Bag of 1000 500191 US$15 960 (10 racks of 96) 500192 US$30 Bag of

More information

78 동방하이테크상사 T.(02) F.(02)

78 동방하이테크상사  T.(02) F.(02) 78 동방하이테크상사 http://www.allpump.co.kr T.(0)7-9 F.(0)7-9 00--7 Introduction to Introduction Rheodyne valves fit virtually any high-pressure flow control application. As you ll see from the table below and

More information

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Agilent Valve Kit G4231A/B/C and G4232B/C/D Agilent Valve Kit G4231A/B/C and G4232B/C/D Instructions Agilent Valve Kit G4231A/B/C and G4232B/C/D - Instructions This Technical Note describes the installation of the Agilent G4231A/B/C and G4232B/C/D

More information

2017 HPLC Product Catalog 1

2017 HPLC Product Catalog 1 1 2017 HPLC Product Catalog ORDERING INSTRUCTIONS BY PHONE Call toll-free 800.682.6480 or 952.895.8292. Our normal business hours are 8 a.m. to 5 p.m. (Central Standard Time). BY FAX Dial 952.895.8493

More information

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Agilent Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Your chromatography analysis does

More information

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent Extended ph range from 1-10 provide longer lifetimes with harsh mobile phases Novel bonding reduces residual silanols which cause peak tailing Polymer coated capsule type silica Excellent selectivity for

More information

HPLC Accessories. HPLC Columns HPLC Applications

HPLC Accessories. HPLC Columns HPLC Applications HPLC Accessories Instrument Replacement Parts..........................332-337 Filters, Mobile Phase Accessories........................338-342 Column Heaters, Gas Trapping Systems......................343

More information

NEW? HPLC ACCESSORIES. What s. look for this circle

NEW? HPLC ACCESSORIES. What s. look for this circle HPLC ACCESSORIES Instrument Accessories & Parts..............327-332 Tubing & Connections.......................332-335 Tools & Maintenance.........................336-337 Mobile Phase Accessories Bottle

More information

Vessels and Distillation Equipment

Vessels and Distillation Equipment Vessels and Distillation Equipment 147 A suitable solution for practically every application in well-known BOLA-quality and optimally adapted to your needs. PRODUCT TIPS BOLA Scrubber Columns Pressure:

More information

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like

More information

ÄKTA system Training Guide

ÄKTA system Training Guide ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector

More information

SERIES 86 INSTRUMENTATION 3-PIECE TUBE FULL PORT BALL VALVES

SERIES 86 INSTRUMENTATION 3-PIECE TUBE FULL PORT BALL VALVES SERIES 86 INSTRUMENTATION 3PIECE TUBE FULL PORT BALL VALVES SHARPE SERIES 86 INSTRUMENTATION BALL VALVES STANDARD FEATURES Tube Full Port Design (TFP) 3Piece Design Integral ISO Mounting Pad Lockable Handle

More information

Kontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos Four Valve Filtration / Delivery Caps

Kontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos Four Valve Filtration / Delivery Caps Kontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos. 953983-0047 953983-6347 Four Valve Filtration / Delivery Caps Kontes Article Nos. 953981-0047 953981-6347 Filter Size:

More information

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide Accuracy Starts Here Agilent Captiva Filtration Selection Guide TAbLe of CoNTeNTS Tips & Tools Learn the core concepts surrounding Solid Phase Extraction and best practices for Sample Prep. View the video

More information

1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION

1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION 1Valcor Scientific Subminiature Teflon Valve 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS Model SV20-1 is suitable for a broad range of light industrial applications, both new and retrofit.

More information