ÄKTA system Training Guide
|
|
- Simon Lester
- 6 years ago
- Views:
Transcription
1 ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience
2 ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector Outlet Valve Pumps Mixer Pump A Pump B Buffer switching valve
3 ÄKTApurifier 0 / 00 In-line filter UV Wavelength detector Injection valve (V) Cond. Conductivity monitor System pumps Mixer ph ph detector A B Fraction collector Frac-90 8 Outlet valve (V) ÄKTApurifier + Sample Pump + Sample Valve In-line filter System pumps A Mixer B Injection valve (V) UV Cond ph Wavelength detector Conductivity monitor ph detector Sample pump 8 Fraction collector Frac-90 8 Outlet valve (V) Sample selection valve (V)
4 ÄKTApurifier 00 Air In-line filter UV Wavelength detector Injection valve (V) Cond. Conductivity monitor System pumps Mixer ph ph detector A B Fraction collector Frac-90 Air sensor 8 Outlet valve (V) ÄKTApurifier + Buffer Valve In-line filter UV Wavelength detector Injection valve (V) Cond. Conductivity monitor System pumps Mixer ph ph detector A B Fraction collector Frac-90 8 Outlet valve (V) 8 Buffer select valve (V)
5 ÄKTApurifier 0 XT In-line filter UV Wavelength detector Injection valve (V) Cond. Conductivity monitor System pumps Mixer ph ph detector A B Fraction collector Frac-90 8 Outlet valve (V)
6 PUMP P-900 Mixer Pump A Pump B Proportion Valve A A B B Buffer Acid /Alkali Salt Water ÄKTA 0 mls/min ÄKTA 00 mls/min GRADIENT < mls/min - mls/min <0 mls/min 0-0 mls/min 0-00 mls/min MIXER 0. ml mixer ml mixer mls mixer mls mixer mls mixer
7 PUMP P-900 Inlets Mixer Pump A Pump B Switching Valves Buffer Select Valve IV-908 A A B B 8 Water Salt A A A A A A A8 A
8 PUMP P-900 Manually Priming Buffer Inlet Lines Pump A Pump B Common inlet A A Common inlet B B Manual Flowpath Manual Flowpath A or A BufferValveA B or B BufferValveB Open Draw Air out of Buffer Line
9 PUMP P-900 Back - Wash Lines Pump Back-Wash Lines Syringe fitting Wash OUT IN-LINE one-way valve High pressure Piston seal Buffer OUT Ball outlet check valve 0% Ethanol : Water Piston Backwash pump diaphragm Wash IN Buffer IN Ball inlet check valve
10 ON-LINE FILTERS P-90 ( 0 ml/min Pump ) Low Flow HPLC Filter P-90 ( 00 ml/min Pump ) High Flow Fibre Filter Polymer Support LOAD () () LOAD (wash loop) Column Pump Column Pump Column Pump 8 PV PV PV-908 Sample Sample Sample
11 ION VALVE INV- 90 COLUMN LOAD SAMPLE PUMP LOAD COLUMN PUMP COLUMN PUMP WASTE
12 SAMPLE LOADING METHOD COLUMN LOAD SAMPLE PUMP Needle Port Always tighten by hand with needle inserted Do Not Overtighten COLUMN LOAD SAMPLE PUMP Luer Lock Adapter Superloop
13 SUPERLOOPS Buffer 0 ml 0 ml 0 ml Plunger BUFFER FLUSH SAMPLE LOAD SAMPLE SAMPLE FLUSH Sample Etched Groove WASTE PUMP or SYRINGE COLUMN COLUMN Volume Max. allowed column pressure Code No. 0 ml Mpa ml Mpa ml Mpa 8-0-8
14 INV-90 Injection Valve - Injection Port PEEK Valve Body Injection Needle Port Valve Seal Ferrule Needle NeedleTube Needle Adapter
15 INV-90 Injection Valve - Luer Adapter PEEK PEEK Injection Valve Valve Body Body PEEK PEEK Injection Luer Luer Adaptor Valve Valve Seal Seal Valve Valve Channel Plate Plate
16 Fluid Dynamics Flow High Resistance to Flow PEEK Tubing Low Resistance to Flow End Beginning
17 Fluid Dynamics Flow - Injecting a Loop The way we imagine it Flows The way it Actually Flows Bubble Segmentation 0ul Load 00ul Loop 0ul Load 00ul Load 00ul Load Partial Loading Loop = No more than / Loop Volume Total Loading Loop = Inject X Loop Volume
18 LOADING A SAMPLE LOOP Column Load Inject Injection valve INV-90 Pump Sample Sample pump P-90
19 LOADING A SUPER LOOP Column Load Inject Injection valve INV-90 Pump Buffer Sample Sample
20 MULTI-LOADING A SAMPLE LOOP Column Load Inject Injection valve INV-90 Pump PV I/O Samples Wash
21 MULTI-LOADING A SUPER LOOP Column Injection valve INV-90 Pump Load Inject PV-908 I/O 8 Samples S S S S Wash S8
22 DIRECT LOADING ON TO COLUMN Column Pump Inject Load Extra Tube / or /8 Tubing Sample
23 REVERSE FLOW VALVE ( INV-90 ) Pump Column Extra Tube Stop Plug MONITOR Downward Flow Position Pump Column Extra Tube Stop Plug MONITOR Upward Flow Position
24 OUTLET VALVE PV-908 DETECTOR Default To Fraction Collector F F F F8 I/O F F F F F F F F F F8
25 Fraction Collection Flowthrough Fractionation Eluate Fractionation Peak Fractionation mau 00 0%B 00%B %B 00 0 Inject UNBOUND Start BOUND End A A A.
26 Phenyl Sepharose HiTrap Connections / Female / Male 8-- / Fingertight Fitting / Female M Male 8-- M male / / Female HiTrap Column M Male M Female 8--8 M female / / male / Male Flow Cell Inlet
27 Phenyl Sepharose Phenyl Sepharose Phenyl Sepharose Phenyl Sepharose Phenyl Sepharose Phenyl Sepharose Multiple HiTrap Arrangment ( Series ) Detector Detector Detector
28 Traditional FPLC fitting to ÄKTA / HPLC Injector / Fingertight Fitting ul / FEMALE / M FEMALE 8--9 Flange M Fitting / MALE / M FEMALE 8--8 Flow Cell
29 Tubing Fittings 8-- / Fingertight Fitting / PEEK TM Tubing 8--8 Flange Fitting Adapter FPLC Flange Fitting 8-- Luer Fitting Adapter Luer Syringe 8-- Fingertight Stop Plug 8--0 / Stop Plug Flangless Inlet Connector / 8--9 /8 8-- / 8--0 Flangless Buffer Inlet Ferrule / 8--8 / / M male / / Female Tubing Connector M male / O - ring / female X / female Union Ti Union + Fingertight Fittings 8--9 M female X / female Union FPLC Flange - / Fingertight
30 COMPRESSION FITTINGS Untightened Correctly tightened Obstructed Over tightened Tubing Restricted
31 PEEK TM Tubing Gray, / x.0 mm (.8ul / cm ) Green, / x 0. mm (.ul / cm ) Orange, / x 0. mm (.9ul / cm ) Blue, / x 0. mm ( 0.9ul / cm ) Teflon / Tefzel Tubing / OD 8-- /8 OD 8-- / OD 8-9-
32 Tubing Kit Changes - ÄKTApurifier 0 GENERAL FLOW (at delivery) G 00 ul Injection valve V G9 Outlet Valve V (ul) UV Flow cell G8 Accumulator (0ul) 0. mm i.d Blue PEEK G 00mm G 0mm G 80mm G8 0mm G9 00mm G Conductivity Flow cell (ul) G ph Flow cell (00ul) FR-90 (0.Mpa, ul) NB: Never use the FR-90 with the ph electrode Tubing Kit No Frac Frac 90 Frac 90 AKTApurifier 0, 0.0 tubing kit 8 AKTApurifier 0, 0.0 tubing kit + ph electrode 0 AKTApurifier 0, 0. tubing kit 88 8
33 Tubing Kit Changes - ÄKTApurifier 0 HIGH FLOW G 00 ul Injection valve V H9 Outlet Valve V (ul) UV Flow cell H8 Accumulator (0ul) H Conductivity Flow cell (ul) H 0.0 mm i.d Orange PEEK H 0mm H 80mm H8 0mm H9 00mm NB: Never use the FR-90 with the ph electrode ph Flow cell (00ul) FR-90 (0.Mpa, ul) Tubing Kit No Frac Frac 90 Frac 90 AKTApurifier 0, 0.0 tubing kit 8 AKTApurifier 0, 0.0 tubing kit + ph electrode 0 AKTApurifier 0, 0. tubing kit 88 8
34 Tubing Kit Changes - ÄKTApurifier 00 HIGH FLOW (at delivery) G 00 ul Injection valve V G9 Outlet Valve V (ul) UV Flow cell G8 Accumulator (0ul) 0. mm i.d Green PEEK G G G8 G9 0mm 80mm 0mm 00mm G Conductivity Flow cell (ul) G ph Flow cell (00ul) FR-90 (0.Mpa, ul) NB: Never use the FR-90 with the ph electrode Tubing Kit No Frac Frac 90 Frac 90 AKTApurifier 00, 0.0 tubing kit 8 AKTApurifier 00, 0. tubing kit 0 0 AKTApurifier 00,.00 tubing kit AKTApurifier 00, 0.0 tubing kit + ph electrode 0 AKTApurifier 00, 0. tubing kit + ph electrode 8 AKTApurifier 00,.00 tubing kit + ph electrode 9 99 AKTAbasic 00, 0. tubing 90
35 Tubing Kit Changes - ÄKTApurifier 00 LOW FLOW L 00 ul Injection valve V L9 Outlet Valve V (ul) UV Flow cell L8 Accumulator (0ul) 0.0 mm i.d Orange PEEK L L L8 L9 0mm 80mm 0mm 00mm L Conductivity Flow cell (ul) NB: Never use the FR-90 with the ph electrode L FR-90 (0.Mpa, ul) ph Flow cell (00ul) Tubing Kit No Frac Frac 90 Frac 90 AKTApurifier 00, 0.0 tubing kit 8 AKTApurifier 00, 0. tubing kit 0 0 AKTApurifier 00,.00 tubing kit AKTApurifier 00, 0.0 tubing kit + ph electrode 0 AKTApurifier 00, 0. tubing kit + ph electrode 8 AKTApurifier 00,.00 tubing kit + ph electrode 9 99
36 A-900 Autor COLUMN PUMP MANUAL SAMPLE LOAD LOAD Syringe Sample INV-90 A-900 COLUMN PUMP MANUAL SAMPLE LOAD Syringe Sample INV-90 A-900 LOAD LOAD
37 Needle Height Standard Vial Needle Height volume left mm 0ul Standard Vial + Insert mm 0ul mm ul 0mm 00ul
38 A-900 Sample Injection ( Flushed Loop Injection ) LOAD LOAD pump pump pump pump waste waste waste waste column column column column Sample needle Wash Reservoir In In,, In In LOAD LOAD The The flushes flushes the the valve valve is is drawn drawn up up to to channel. channel. completely completely Min. Min. ( ( 0ul 0ul ) ) with with fill fill the the loop. loop. Air Air Segment Segment ( ( no no less less than than twice twice Min. Min. ( ( ul ul ) ) without without loop loop volume volume Air Air segment segment recommended recommended ) ) In In is is washed washed onto onto the the column. column. Final Final internal internal needle needle wash. wash. waste pump column Optional Optional External External needle needle wash. wash. transport fluid
39 A-900 Sample Injection ( Partial Loop Injection ) LOAD LOAD waste pump pump pump pump waste column waste column waste column waste column Sample needle Sample needle Sample needle Wash Reservoir In In,, flushes flushes the the valve valve channel. channel. Min. Min. ( ( 0ul 0ul ) ) with with Air Air Segment Segment Min. Min. ( ( ul ul ) ) without without Air Air segment segment The The is is drawn drawn up up to to partially partially fill fill the the loop loop with with programmed programmed volume. volume. ( ( no no more more than than half half loop loop volume volume recommended recommended ) ) In In inject inject is is washed washed onto onto the the column. column. Final Final internal internal needle needle wash. wash. waste pump column Optional Optional External External needle needle wash. wash. transport fluid
40 A-900 Sample Injection ( ul Pick-up Injection ) LOAD LOAD LOAD LOAD pump pump pump pump waste column column column column transport fluid Sample needle Sample needle Sample needle In In inject, inject, valve valve flushes flushes with with transport transport fluid fluid The The is is drawn drawn up up from from the the vial vial The The is is washed washed into into the the loop loop with with transport transport fluid fluid In In inject inject is is washed washed onto onto the the co column lumn pump pump waste Final Final internal internal needle needle wash. wash. waste Wash Reservoir column Optional Optional needle needle wash. wash. transport fluid column
41 System Compensation Volume Equilibration Phase A COLUMN TOP B 0% A COLUMN TOP B 0% Effect 8 mls Command 0%B 0%B 8mls
42 A Gradient Delay Volume Gradient Phase COLUMN TOP B 0% A COLUMN TOP B 00% Effect mls Command 00% 00%B Gradient Delay
43 Column Pressure ( compensation ) Flow Restrictor Column Pressures Column Hardware Pressure Limits Column Matrix Pressure Limits Column Shatters DANGEROUS Matrix Collapses EXPENSIVE Reading Reading Atmos Atmos Press Press MPa MPa Reading Reading Pre-column pressure = 0 MPa Pump Pump Mpa Mpa Pre-column pressure = 0 MPa Pump Pump Mpa Mpa 0. MPa 0. MPa Gel Top Pressure GEL GEL Press Press Drop Drop Column Column Press Press Drop Drop MPa MPa MPa MPa (0. ( ) 0.0) (0. ( ) 0.0) 0.0 MPa Gel Bottom Pressure GEL GEL Press Press Drop Drop MPa MPa (0. ( ) 0.) 0. MPa Colu Colu mn mn Press Press Drop Drop MPa MPa (0. ( ) 0.) MPa MPa MPa MPa Flow Flow Restrictor
ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science
ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bio science ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector
More informationMotor Valve MV-7/IMV-7
Motor Valve MV-7/IMV-7 INSTRUCTIONS 1. Introduction Motor Valves MV-7/IMV-7 are a 3-position, 7-port motorized valves designed to he used as automatic sample injection valves or system valves. The valves
More informationGE Healthcare. Valve INV-917. Instructions
GE Healthcare Valve INV-917 Instructions INV-917 2 1 3 7 4 5 6 Important user information All users must read this entire manual to fully understand the safe use of Valve INV-917. Important! Valve INV-917
More informationChromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO
8 SupelPRO Valves Order:.800..00 Technical Service:.800.9.0 Web: www.sigma-aldrich.com/supelco SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled,
More informationGE Healthcare. ÄKTApilot. User Manual
Pilot_UM.book Page 1 Tuesday, May 8, 2007 1:06 PM GE Healthcare ÄKTApilot User Manual Important user information All users must read this entire manual to fully understand the safe use of ÄKTApilot. WARNING!
More informationS 1125 HPLC Pump System
Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make
More informationFITTINGS, LOOPS, AND VALVE ACCESSORIES
FITTINGS, LOOPS, AND VALVE ACCESSORIES Fittings Rheodyne offers a variety of fittings. They differ in material of construction, tubing size, and pressure rating. Materials/Biocompatibility. 316 stainless
More informationApplication Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!
Inlet Solvent Filters Filters and Degassers General Use Inlet Solvent Filters Large Surface Areas disposable µm, 0 µm, and 0 µm Pore Sizes Available General Use and Prep Filters for Higher Flow Applications
More informationHPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.
1. Overview The front panel houses the UV detector lamp switch, Rheodyne injection valve, prime/purge valve, pressure gauge, and the storage compartment. In the storage compartment are the LED display
More informationÄKTA avant 150. Product Documentation
ÄKTA avant 150 Product Documentation Table of Contents Table of Contents 1 Introduction... 1.1 Instrument view... 1.2 Liquid flow path... 2 General specifications... 2.1 System specifications... 2.2 Enviromental
More informationSpark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art
BETTER SAMPLE CARE Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art autosampler for ÄKTA pure Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art autosampler
More informationHIGH PRESSURE SWITCHING VALVES
HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available
More informationValving Schemes for the BioLogic Duo-Flow Chromatography System
Valving Schemes for the iologic Duo-Flow Chromatography System table of contents pplication asic ion Valve Operation using,, and Purge Positions position is for filling a loop with sample or for running
More informationQuick Reference Guide. Supplies for Waters HPLC Systems
Quick Reference Guide Supplies for Waters HPLC Systems works with WATERS SHIMADZU THERMO/DIONEX BRUKER/VARIAN PERKINELMER CTC MORE Put innovation and quality to work on a wide range of GCs and HPLCs in
More informationAgilent SD-1 Purification System ml/min
Agilent SD-1 Purification System - 200 ml/min Introduction Installation of the Capillary Kit This technical note shows you how to install the Stainless Steel Capillary Kit (SD- 1 Purification System -
More informationNEW HPLC - SYSTEM LINE
NEW HPLC - SYSTEM LINE S c h a m b e c k S F D G m b H Drieschweg 13A D-53604 Bad Honnef/Germany Phone: +49 2224 9239-0 E-Mail: info@schambeck-sfd.com Internet: www.schambeck-sfd.com S 9425 HPLC solvent
More informationPhysiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN
80-6000-32 Physiological Calibration Standard II 80-2037-62 Calibration standard physiological fluid 80-2037-61 CALIBRATION STANDARD PROTEIN HYDROLYSATE 80-2104-53 1/8" FLANGELESS FITTING (PK 5) 80-2108-41
More informationBioLogic DuoFlow Valving Guide
Protein Purification iologic DuoFlow Valving Guide Valving Schemes for the iologic DuoFlow Chromatography System Protein Purification iologic DuoFlow Valving Guide Introduction The iologic DuoFlow Chromatography
More informationHPLC SYSTEM S 500 SERIES
HPLC SYSTEM S 500 SERIES The Sykam HPLC System S 500 Series is intended for all routine analysis as well as for the ambitious analyst. The system configuration is highly variable and several upgrade options
More informationDIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start
DIONEX ELUENT GENERATOR CARTRIDGE DIONEX HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start 1. Preparation for Installation of Dionex If installing a Thermo Scientific Dionex and Thermo
More informationHPLC System S 600 Series
HPLC System S 600 Series The Sykam HPLC System S 600 Series is intended for the ambitious analyst. The system configuration is highly variable and several upgrade options make this system suitable for
More informationPATROL UPLC Process Analysis System for Production
PATROL UPLC Process Analysis System for Production The PATROL UPLC Process Analysis System for Production is an integrated system solution designed and engineered to perform online and atline reaction
More information[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE
WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION Waters Advanced Purification (AP) series of glass columns are constructed of biocompatible glass and polymeric materials and can be easily used with
More informationseal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271
Restek Replacement Parts for Agilent HPLC Systems Meet or exceed OEM performance. Agilent part # qty. cat.# price Preventive Maintenance Kit Includes: rotor seal, needle seat, needle assembly, seat cap
More informationACQUITY UPLC I-Class System with 2D Technology
ACQUITY UPLC I-Class System with 2D Technology The Waters ACQUITY UPLC I-Class System with 2D Technology allows chemists to increase sensitivity and selectivity, eliminate unwanted interferences, characterize
More informationLC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation
LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL 1993 Dionex Corporation Document No. 034859 Revision 02 September 1993 1993 Dionex Corporation All rights reserved worldwide Printed in the United States
More informationLiquid Chromatography LC Consumables SSI-LC
Liquid Chromatography LC Consumables SSI-LC-10-2017 Table of Contents HPLC Pumps...3 LC-30AD... 3 LC-20AD / LC-20AB / LC-20ADXR... 4 LC-20AT... 4 LC-20Ai... 5 LC-10ADvp... 5 LC-10ATvp... 6 LC-10Ai... 6
More informationGradient Pumping for Pressure, Flow, and Concentration Modes
Gradient Pumping for Pressure, Flow, and Concentration Modes With Teledyne Isco Syringe Pumps Syringe Pump Technical Bulletin TB24 Overview Gradient pumping is used in applications requiring time-controlled
More informationC196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications
C196-E081C Ultra High Performance Liquid Chromatograph Nexera X2 Specifications Specifications System Controllers CBM-20A / 20Alite CBM-20A (228-45012-XX) CBM-20Alite (228-45011-XX) Connectable units Solvent
More information8 Installing and modifying components
8 Installing and modifying components 8.2 Optical unit 8.2.1 Connecting the optical unit holder Hook the holder into the slot on the right hand side of the system. Secure it by pushing up the slide clamp.
More informationInstrument Accessories & Parts, Tubing & Connections
Instrument Accessories & Parts, Tubing & Connections ASI Piston Seals for Agilent HPLC Systems Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed
More informationDynaLoop 25 and DynaLoop 90. Instruction Manual
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0 5 10 15 20 25 DynaLoop 25 and DynaLoop 90 Instruction Manual Catalog Numbers 750-0451 (25 ml) 750-0452 (90 ml) For technical support, call your
More information98 동방하이테크상사 T.(02) F.(02)
98 동방하이테크상사 http://www.allpump.co.kr T.(0)57-69 F.(0)57-69 00--7 troduction to Upchurch Scientific Valves Valves troduction Valves jection and Selection Valves for Pressures to,000 psi (69 bar) Switching
More informationGlycoChrom TM HPLC Analyzer. Hardware Installation and System Test
GlycoChrom TM HPLC Analyzer Hardware Installation and System Test PIN 410-5004 For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-8 00-424-6723) ,, Table of Contents
More informationAgilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet
Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet 1. Description The Agilent Dynamax modular HPLC column system uses a unique technology, Dynamic, to maintain the structure of the packed
More informationFlow System Accessories
Flow System Accessories Fitting Systems MicruX is able to provide different accessories, from several suppliers, usually required for using the standard thinfilm (micro)electrodes in flowing liquids systems.»
More informationMODEL 905V OPERATING INSTRUCTIONS
MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions
More informationConductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands
Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationEGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer
EGC II K 2 Cartridge Electrolytic ph Modifier EGC Carbonate Mixer PRODUCT MANUAL FOR THE EGC II K 2 CARTRIDGE EGC II K 2 CARTRIDGE, P/N 058904 ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N 063175 EGC CARBONATE
More informationAgilent 218 Purification Solution
Agilent 218 Purification Solution System User Guide Purification Solution System User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2012, 2013 No part of this manual may be reproduced in
More informationAgilent 1260 Infinity Manual Injector
Agilent 1260 Infinity Manual Injector User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006-2011, 2012 No part of this manual may be reproduced in any form or by any means (including
More informationACQUITY UPLC I-Class System Specifications
ACQUITY UPLC I-Class System s Revision A Copyright Waters Corporation 2011 All rights reserved Copyright notice 2011 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA AND IN IRELAND. ALL RIGHTS
More informationeconomics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE
BETTER SAMPLE CARE Spark Holland introduces OPTIMAS The optimum balance of economics and performance Spark Holland introduces OPTIMAS The optimum balance of economics and performance OPTIMAS The optimum
More information819 Injection Module User s Guide
819 Injection Module User s Guide LT2533/ 2004 Gilson, Inc. All rights reserved August 2004 Table of Contents Declaration of Conformity 1 Introduction 2 Installation 3 Operation 4 Maintenance Unpacking...
More informationUpchurch High Pressure Fittings & Connectors
.010 thru-hole P-742 PEEK ZDV Union. 9 2.050 thru-hole P-760 PEEK ZDV Union P-704 PEEK ZDV Union. 9 2. 9 2 Fingertight Fittings ONE-PIECE FINGERTIGHT FITTINGS INTRODUCTION For Coned Ports For convenience
More informationTECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure
TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like
More informationAgilent 1100 Series Capillary LC System. System Manual
Agilent 1100 Series Capillary LC System System Manual s1 Notices Agilent Technologies, Inc. 2002 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval
More informationLiquid Chromatography
SCINTOMICS Liquid Chromatography Always the right system for your needs. SCINTOMICS: Always the right system for your needs Advanced Research Daily QC Routine and beyond High Performance analytical/semi-preparative
More information78 동방하이테크상사 T.(02) F.(02)
78 동방하이테크상사 http://www.allpump.co.kr T.(0)7-9 F.(0)7-9 00--7 Introduction to Introduction Rheodyne valves fit virtually any high-pressure flow control application. As you ll see from the table below and
More informationHyperShear TM HPLC Mixers
HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex sheer mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume
More informationAgilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve
Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Technical Note This Technical Note describes the purpose, installation, and configuration and use of a diverter valve
More informationMaintaining Your Agilent 1100 Series HPLC System
Operate your lab at peak performance Troubleshoot difficult problems Select the right Agilent supplies For detailed information about supplies from Agilent, please contact your local Agilent sales representative,
More informationHigh Pressure Gradient System. User Manual. Version 1.0 ( )
S 9432 HPLC Pump System High Pressure Gradient System User Manual Version 1.0 (2014-05-26) 2 Table of Contents Contents 1. Introduction 5 1.1 How to Use this Manual 5 1.1.1 Symbols 5 1.2 Safety Information
More informationAgilent 1200 Series Manual Injector
Agilent 1200 Series Manual Injector User Manual 1200 Series MI User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006, 2008 No part of this manual may be reproduced in any form or by
More informationInductive conductivity meter
Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values
More informationPRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )
CRD 200 Product Manual Page 1 of 18 PRODUCT MANUAL FOR CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N 062983) CRD 200 (2 mm) (P/N 062986) Dionex Corporation, 2006 Document No. 065068 Revision 04 November
More informationPrimeLine TM HPLC Pumps
PrimeLine TM HPLC Pumps Isocratic Model 501 Gradient System 500G PrimeLine TM Isocratic and Gradient HPLC Pumps Feature: Self-priming pump head requires no manual priming Patented Floating Pump Seal design
More informationAgilent 1290 Infinity Autosampler
Agilent 1290 Infinity Autosampler Installation of the Large Volume Injection Kit General Information This note describes how to install the large volume injection kit into an Agilent 1290 Infinity Autosampler.
More informationInstallation of the 2 position/10 port valve into the 1100 series thermostatted column compartment
Agilent G1316A Thermostatted Column Compartment Technical Note Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment System Requirements 2 Performance Specifications
More informationVERITY Purification Systems Build the perfect system to fit your research
VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC
More informationGX-271 ASPEC Gilson, Inc. All Rights Reserved. LT
GX-271 ASPEC GX-271 ASPEC World Headquarters Gilson, Inc. 3000 Parmenter Street P.O. Box 620027 Middleton, WI 53562-0027 USA Telephone: 608-836-1551 Fax: 608-831-4451 Gilson S.A.S. 19, avenue des Entrepreneurs
More informationFilters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159
Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 156 Inlet Solvent
More informationGE Healthcare. ÄKTAcrossflow. Instrument Handbook
GE Healthcare ÄKTAcrossflow Instrument Handbook Important user information All users must read this entire manual to fully understand the safe use of ÄKTAcrossflow. ÄKTAcrossflow is intended for laboratory
More informationCombustion ion chromatography with a Dionex Integrion HPIC System
TECHNICAL NOTE Combustion ion chromatography with a Dionex Integrion HPIC System Authors Daniel Khor,1 Jeff Rohrer,1 Adelon Austin,2 Mark Manahan2 1 Thermo Fisher Scientific, Sunnyvale, CA, USA; 2COSA
More informationSample Pretreatment, Accessories
11 Sample Pretreatment, Accessories Sample pretreatment -------------------------- 144 Column protection----------------------- 145~147 Tubing parts ------------------------------ 148~151 Empty columns
More informationQuickSplit TM Flow Splitters
Quick TM Flow ters Quick TM Flow ter Features: Fluid resistor technology eliminates tedious adjustments to capillary tubing for split ratio optimization ratios are stable and reproducible, and not affected
More informationAgilent 1260 Infinity Analytical SFC System
Agilent 1260 Infinity Analytical SFC System User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2010-2013 No part of this manual may be reproduced in any form or by any means (including
More informationNeedle OD (mm) Needle ID (mm) Needle Gauge
s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml = 10.8 mm 60 mm (5 µl and 10 µl are 54.1 mm) Code 6
More informationRIGOL Installation Reference
RIGOL Installation Reference L-3000 HPLC System Oct. 2014 RIGOL Technologies, Inc. RIGOL General Safety Summary Please review the following safety precautions carefully before putting the instrument into
More informationConnector Ferrule Regulator Tube Syringe MR pump accessory Parts for KeyChem -L, Basic Parts for KeyChem -Lumino Parts for KeyChem -Flash Software
Connector Ferrule Regulator Tube Syringe MR pump accessory Parts for KeyChem -L, Basic Parts for KeyChem -Lumino Parts for KeyChem -Flash Software Accessori ies and parts Connector Connector 1/16 in. (10
More informationMobile Phase Accessories
NEW! Now available for GL-45 bottles! Bottles not included Waste Overflow Indicator Avoid messy pooling around mobile phase waste containers. Audible alarm instantly alerts user, preventing overflow. Compact,
More informationHyperShear TM HPLC Mixers
HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex shear mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume
More informationAgilent 1200 Series Valves
Agilent 1200 Series Valves User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including electronic storage and
More informationOne-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.
Fingertight Fittings 4 One-Piece Fingertight Fittings Upchurch Scientific s original One-Piece Fingertight Fittings have 0-3 threads and are designed to be used with /6 OD tubing, except the M-645 (6-40,
More information[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS
MS Identification of Trace level Impurities from a Non-MS Compatible Mobile Phase Using ACQUITY UPLC System with 2D Technology by Heart-cutting and Online Sample Concentration Bronsky Gopinadh, Dilshad
More informationVarian Dual Chamber Dynamic Mixer Instruction Manual
Varian Dual Chamber Dynamic Mixer Instruction Manual Installation Category II Pollution Degree 2 Safety Class 1 (EN 61010-1) Publication no. 0391467400 Issue 5 February 2009 Varian, Inc. Serving Industries
More informationPneumatic control units. SeleJet Pneumatic on/off and control valves
SeleJet Pneumatic on/off and control valves NEW SeleJet NEW Quick fit nozzle holders for individual nozzle shut-off with flow-stop Four-way or two-way nozzle holders with individual pneumatic nozzle shut-off.
More informationAUTOMATIC AMINO ACID ANALYSER AAA 400
INGOS Ltd. AUTOMATIC AMINO ACID ANALYSER AAA 400 User manual PRAGUE Apr 11 006 Producer : Laboratory Instruments division of INGOS Ltd. Development : PiKRON Ltd. Chemical system : V. Havlíček - ZMBD chemik
More informationHPLC Tubing and Fittings Hints & Tips for the Chromatographer
HPLC Tubing and Fittings Hints & Tips for the Chromatographer By William S. Letter (Chiralizer Services, L.L.C.) INTRODUCTION: Setting up a high pressure liquid chromatography (HPLC) system to run trouble-free
More informationInstrumentation of HPLC. HPLC Solvent Pumping Systems
Instrumentation of HPLC HPLC Solvent Pumping Systems i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference
More informationInductive conductivity meter
Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct
More informationSystem Manual. Agilent 1260 Infinity Capillary LC System
System Manual Agilent 1260 Infinity Capillary LC System Notices Agilent Technologies, Inc. 2010, 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationChrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter
HPLC ACCESSORIES IDEX Injection Valves IDEX Injection Valves Manual IDEX MANUAL INJECTION VALVES DESCRIPTION POS. SENSING SWITCH MAX PSI FITTING HIGH PRESSURE, ANALYTICAL (accepts a 22 gauge needle) FITS
More informationPrepStar SD-2 Solvent Delivery Module
Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA PrepStar SD-2 Solvent Delivery Module Operation Manual Varian, Inc. 2001 03-914903-00:Rev. 1 Table of Contents Introduction...
More informationAgilent InfinityLab LC Purification Solutions SELECTION GUIDE
gilent InfinityLab LC urification Solutions SELECTION GUIDE GILENT INFINITYLB LC URIFICTION SOLUTIONS EFFICIENT LC URIFICTION SOLUTIONS FOR NLYTICL TO RERTIVE SCLE gilent InfinityLab LC urification Solutions
More informationHPLC Essentials Genuine Restek Replacement Parts for HPLC Systems
HPLC Essentials Genuine Replacement Parts for HPLC Systems 20 YEARS Turning Visions into Reality 800-356-1688 814-353-1300 2 Becky Wittrig HPLC Products Marketing Manager 4+ years of service! did you know?
More informationEPOND SA CP 389 CH Vevey Switzerland.
EPOND SA CP 389 CH - 1800 Vevey Switzerland http://www.e-pond.biz SC-2 & SC-4 Accessories Commonly used Nebulizers with SC-2/SC-4 and FAST PFA-ST Nebulizer, High Pressure (Detachable ES-2040-57 Capillary)
More information845Z Injection Module User s Guide
845Z Injection Module User s Guide LT2575/ 2004 Gilson, Inc. All rights reserved May 2004 Table of Contents Declaration of Conformity 1 Introduction 2 Installation 3 Operation 4 Maintenance Unpacking...
More informationAgilent G5632 Valve Kit Instructions
Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Contents Typical Applications 2 Alternating Column Regeneration (2 position/10 port valves only) 2 Dual column selection 3 Sample
More informationGLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913
GLENCO Syringes As a complement to the Spectra/Chrom chromatographic products, Spectrum manufactures precision syringes for sample injection and collection. These syringes are designed specifically to
More informationLC Instrument Replacement Parts
LC Instrument Replacement Parts /SSI Parts /SSI Pump Replacement Parts Alltech Pump Replacement Parts Misc. Pump Supplies Agilent Parts & Supplies for Agilent Instrumentation 1260 Infinity Isocratic LC
More informationWaters 1500-Series HPLC Pump and Options Operator s Guide
Waters 1500-Series HPLC Pump and Options Operator s Guide 715002013/Revision C Copyright Waters Corporation 2009-2015 All rights reserved Page ii General Information Copyright notice 2009-2015 WATERS CORPORATION.
More informationAgilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer
Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer Technical Note This Technical Note describes the installation of the G9324A Delay Coil Organizer to an Agilent Infinity II system. Contents
More informationDetermination of Sudan Dyes I IV in Curry Paste
Determination of Sudan Dyes I IV in Curry Paste Suparerk Tukkeeree and Jeffrey Rohrer 2 Thermo Fisher Scientific, Bangkok, Thailand; 2 Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 23 Key
More informationC OMPONENT S F O R A C L O S E D - S YS T E M HPL C
C OMPONENT S F O R A C L O S E D - S YS T E M HPL C TM Western Analytical Products, Inc hplc and gc columns and accessories fittings, tubing, valves, frits and filters lab and industrial safety products
More informationFittings SECTION 1 OF 4 SECTIONS ON FITTINGS
Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Deburring an Upchurch Scientific fitting in Oak Harbor, WA. The Very High Pressure (VHP) reusable fitting, VHP-320, is one of the exciting new products in the
More informationDionex CRD Carbonate Removal Device
Thermo Scientific Dionex CRD Carbonate Removal Device Product Manual P/N: June 2013 Part of Thermo Fisher Scientific Product Manual for Dionex CRD Carbonate Removal Device 180 CRD 180, 0.4 mm (P/N 079960)
More information2017 HPLC Product Catalog 1
1 2017 HPLC Product Catalog ORDERING INSTRUCTIONS BY PHONE Call toll-free 800.682.6480 or 952.895.8292. Our normal business hours are 8 a.m. to 5 p.m. (Central Standard Time). BY FAX Dial 952.895.8493
More informationAgilent 1260 Infinity Bio-inert Manual Injector
Agilent 1260 Infinity Bio-inert Manual Injector User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011-2012 No part of this manual may be reproduced in any form or by any means (including
More information10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual
1260 Infinity Binary Pump User Manual 10 Maintenance Introduction to Maintenance and Repair 148 Warnings and Cautions 149 Cleaning the Module 151 Overview of Maintenance and Simple Repairs 152 Maintenance
More information