Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO
|
|
- Amberly Briggs
- 5 years ago
- Views:
Transcription
1 8 SupelPRO Valves Order: Technical Service: Web: SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled, motorized valve instruments for repetitive fluid switching operations. Each SupelPRO instrument is self-contained and incorporates a -position or multi-position port valve. Standard multi-position models include a -line BCD port, and the -position models include the Level Logic. Power requirements: 00-0VAC, 0-0Hz (auto switching). All units shipped with standard US power cord. Other power cords are available on a custom basis. All SupelPRO units are CE approved. SupelPRO -Column or -Column Selector Select from among up to columns or up to columns. Useful for column selectivity comparisons, other column selection applications. Includes mounting clips and cover. -Column Stainless Steel 0-U PEEK -U -Column Stainless Steel -U PEEK -U SupelPRO -Channel Selector with Bypass Valve This -port, -position motorized valve is useful for selecting of connected columns, or flush. Stainless Steel -U PEEK 7-U POSITION B A A B POSITION B A A B POSITION B A A B Column Column Column Column Column Column Pump In Sample Injector Out Detector -U -U
2 SupelPRO Valves 87 S S S S S S S7 S8 S9 S0 0 Solvent Solvent POSITION POSITION POSITION POSITION Sample Injector Solvent Solvent 9 Solvent Solvent To Pump -U 8-U -U SupelPRO -Port, 0-Position Valve Use this -port, 0-position valve to select from up to 0 inputs to output, or select 0 outputs from input. Stainless Steel -U PEEK -U SupelPRO -Position Valves Available with or 0 ports. Useful for a wide variety of applications, including sample clean-up and back-flushing. -Port Stainless Steel 8-U PEEK 9-U 0-Port Stainless Steel 0-U PEEK -U SupelPRO Solvent Selector Valve Allows automation of mobile phase selection from inlets. Comes with factory installed /" or /8" OD tubing and /-8 fittings. Rated to 00psi (0 bar). /" -U /8" -U Order: Technical Service: Web:
3 88 Rheodyne Injectors 890-U Order: Technical Service: Web: Rheodyne Model 7000 Stream Switching Valve Designed specifically for column selection, sample clean-up and 7 enrichment, column programming, backflushing, and other stream switching operations. Six peripheral ports (no center port) are interconnected through a two-position rotor. Low volume flow passages (0.mm ID) minimize dead volume that can affect Rheodyne Model 7i Preparative Sample Injectors column switching analyses. The pressure limit is factory set at Model 7i sample injectors for -0cm ID HPLC columns 000psi (0kg/cm²), but can be adjusted to 7000psi (90kg/cm²). combine the ease of use and versatility of Rheodyne s analyticalscale injectors with the ability to handle large samples and high The flat-face seal is easy to adjust. flow rates. Rugged and easily maintained, in a choice of stainlessmodel 7000 Valve 890-U steel or PEEK flowpaths. Includes 0mL sample loop, /8" fittings for all ports, cm large-bore syringe needle ( gauge/0." OD) VESPEL Rotor Seal 88 for rapid injection of large samples, needle port cleaner, two vent RheBuild Kit for 7000/700 0 tubes, wrenches, mounting screws, and instructions. SPECIFICATIONS Tubing and Fittings: /8" Valve Flow Passages: mm/0.0" Flow Rates: 0-800mL/min Pressure Rating: PREPARATIVE SAMPLE INJECTORS Model 7i, PEEK 7 Model 7i-08, SS 7 Rotor Seal 77 Stator Face Assembly 77 Needle, PEEK for model 7 77 Needle, -Gauge SS for model 7 77 Fitting Set, /8" ( nut & ferrule) RheFlex 777 Stainless Steel 779 Ferrules, /8" (pk. of ) Stainless Steel 780-U RheBuild Kit for 7/7i/7-08/7i-08 0 SAMPLE LOOPS, PEEK ml 7-U ml 7 0mL 7-U 0mL 77 Stainless Steel ml 78-U ml 79 0mL 770-U 0mL 77 P0008 Model 7i: 7 bar/000psi* Model 7i-08: bar/000psi * Usable pressure depends on sample loop ID, organic solvent concentration, and organic solvent exposure time. P0007 P Rheodyne Model 700 Injector The original Rheodyne HPLC injector, Model 700 introduces µl-ml samples onto a column with excellent reproducibility (intended for complete loop filling only). Six clustered ports allow compact interconnections, minimizing tubing volume. The flat-face seal is easy to adjust and service. Operates at pressures to 7000psi (90kg/cm²). Supplied with a 0µL loop; order fill port separately. Model 700 Injector 887 Loop Fill Port 88-U VESPEL Rotor Seal 88 RheBuild Kit for 7000/700 0 SAMPLE LOOPS WITH FITTINGS µl 880-U 0µL 88 0µL 88-U 0µL 88 00µL 88 00µL 88 00µL 887 ml 888 ml 889 ml 77 Supplied with unswaged fittings for connection to Model 7i injector. Two /8" x /" reducing unions (Cat. No. 999), two short pieces of /" capillary tubing, and /" nuts and ferrules are needed to connect a preparative sample loop to a valve with /" ports.
4 Rheodyne Injectors 89 Rheodyne Model 700 Selection Valve For column or mobile phase selection. P0007 Instead of frequently connecting and disconnecting columns to your system, connect the injector outlet to the common center port of a Model 700 valve, and connect up to columns to the peripheral ports. (We recommend allowing one port for bypass/ flushing operations.) The common port can be sequentially connected to each of the peripheral ports by manually rotating the handle in either direction. Connect the column outlets to a second Model 700 valve to direct the flow from the columns to the detector. Low dispersion 0.mm/0.0" ID passages and an internal volume of less than µl ensure minimal extra-column band broadening. Model 700 Selection Valve 887 Rheodyne Model 70 Microsample (Syringe-Loading) Injector P0007 Designed specifically for use with narrow bore HPLC columns. 0.mm/0.00" ID passages and a built-in needle port (0.µL hold-up volume) minimize dispersion of small samples. A 0.µL sample rotor is included; order other rotors separately. Model 70 Microsample Injector 889 RheBuild Kit for 70/7 08 SAMPLE ROTORS 0.µL 880.0µL 88-U P0008 Rheodyne Model 7 Injector The Rheodyne Model 7 syringe loading injector allows injection of the entire contents of the syringe into the sample loop you won t have to flush the valve between injections, unless you are conducting trace analyses. It also injects samples from a partially filled loop (you save time by not having to change the sample loop). The Model 7 injector can be used at pressures to 7000psi (90kg/cm²) and is supplied with a VESPEL rotor seal for operation at ph 0-0. A 0µL sample loop is included; order additional loops separately. Model 7 Injector 88 VESPEL Rotor Seal 880-U Tefzel Rotor Seal 7 Needle Port Cleaner 7 Valve Angle Bracket (for all metal Rheodyne valves) 7 RheBuild Kit for 7/7 0 SAMPLE LOOPS WITH FITTINGS µl 880-U 0µL 88 0µL 88-U 0µL 88 00µL 88 00µL 88 00µL 887 ml 888 ml 889 ml 77 Note: Use VESPEL seals to ph 0, Tefzel seals to ph. Order: Technical Service: Web:
5 90 Rheodyne Injectors Order: Technical Service: Web: Rheodyne Model 77 and 77i Injectors The Rheodyne Model 77 injector allows you to inject µl-ml samples with accuracy and precision. The rugged, easily dmaintaine design offers many advanced features: Patented continuous flow design (Figure A) flow is uninterrupted when you switch from LOAD to INJECT Easy seal adjustment using pressure screw on front of injector Easy access to fittings (Figure B) Injector includes a 0µL sample loop and is supplied with a VESPEL rotor seal that can be replaced with a Tefzel rotor operation seal for at ph 0-. Factory set at 000psi ( bar), adjustable to 7000psi (8 bar). Model 77i has an internal position sensing itch. sw Model 77 Injector 70-U Model 77i Injector 7 VESPEL Rotor Seal 880-U Tefzel Rotor Seal 7 Stator Face Assembly 7 Needle Port Cleaner 7 Valve Angle Bracket (for all metal Rheodyne valves) 7 RheBuild Kit for 77/77i/77 09 SAMPLE LOOPS(WIDE-ANGLE PORTS; FITTINGS INCLUDED) µl 7 µl 7 0µL 7 0µL 7 0µL 7 00µL 77 00µL 78-U 00µL 79-U ml 70 ml 7 ml 7 Note: Use VESPEL seals to ph 0, Tefzel seals to ph. Model 8 Injector 790-U VESPEL Rotor Seal 79 RheBuild Kit for 8/8 00-U SAMPLE LOOPS µl 79 0µL 79 0µL 79 Figure A. A Model 77 Injector Reduces Wear and Tear on Your Columns To Loop 7 77 P U From Loop From Pump MBB Passage MBB Port To Column A conventional HPLC valve momentarily interrupts flow during sample injection, subjecting your column to repetitive pressure shocks. Rheodyne s patented MBB (make-before-break) design makes the new connection before breaking the old one, providing uninterrupted flow. Figure B. Model 77 Injectors also Feature a Wide Port Angle (0 ), for Easy Access to the Fittings Rheodyne Model 8 Low Dispersion Injector 889 Inject as little as 0.µL of sample with high accuracy and zero waste. Small diameter flow channels in a low-dispersion version of the popular Model 7 injector. Excellent for use with narrow bore columns (-mm ID), but also well suited for larger diameter columns. Resolution is most improved with relatively unretained ow k ) (l peaks the peaks most affected by extra-column effects. Additional features include: Built-in zero-holdup needle port Built-in position switch to signal injection Long rotor seal lifetime make up to 0,000 injections before replacing seal (VESPEL) User-adjustable to 7000psi (90kg/cm²) Easy-to-service flat-face rotor design Supplied with a µl sample loop, fittings for all ports, -gauge luer hub needles, needle port cleaner, two vent tubes, wrench mounting screws and instructions. Order additional sample loops separately.
6 Rheodyne Injectors 9 Biocompatible Rheodyne Injectors All flow passages in the -port injectors on this page are inert PEEK (polyetheretherketone) or alumina-ceramic materials. are They unaffected by buffers, acids, bases, or halide salts, including M sodium chloride, over the entire ph range. Both valves ated for are r pressures up to 000psi (0kg/cm²), but the usable operating pressure may be lower, depending on the loop and solvents used. P0070 P Rheodyne Model 900 Injector This injector is similar in function to the Model 700 stainless steel injector, but is constructed of inert PEEK and Tefzel materials for use in the ph range 0-. It can be used for HPLC, soft gel chromatography, or ion chromatography. A position-sensing switch closes in the INJECT position and stays closed until the handle is returned to the LOAD position. Supplied with a 0µL sample loop; order additional loops separately. Model 900 Injector 79 Tefzel Rotor Seal 79 Loop Filler Port 78 Needle Port 79 RheBuild Kit for 900/900 0 Rheodyne Model 97 Injector The Model 97 injector is ideal for both HPLC and soft gel LC purification procedures for biomolecules. Performance of this - port rotary injector is similar to that of the Model 77 injector, but no metal contacts the samples. Model 97 incorporates the patented make-before-break design (see previous page, Figure A). The 0.mm ID flow channels provide low dispersion when used with narrow ID columns, but prevent excessive flow resistance at flow rates used with larger analytical columns and preparative columns. Use with Rheodyne HPT fittings and high pressure PEEK tubing. Model 97i includes a position-sensing switch. Supplied with a 0µL PEEK sample loop, Tefzel rotor seal, fittings for all ports, -gauge luer hub needle, needle port cleaner, two Tefzel vent tubes, wrenches, mounting screws and instructions. Order additional sample loops separately. Model 97 Injector Tefzel Rotor Seal 797-U RheBuild Kit for 97/97i/97 0 PEEK Sample Loops for 900, 9, and 97 Injectors VOLUME CAT. NO. PRICE µl 70 0µL 7 0µL 7 0µL 7 00µL 7 00µL 7 00µL 7 ml 77 ml 78 ml 79 Order: Technical Service: Web:
7 9 Rheodyne RheBuild Kits, Fittings, Tools Needle Port Cleaner Stator Face Assembly 087-U Rheodyne Port Adapter, ValvTool Use the Port Adapter for connecting /" tubing to a /8" valve port. Use the ValvTool for changing sample loops or replacing fittings on Rheodyne valves. The / end is a uniquely designed slotted socket wrench that provides easy access to many hard-toreach areas. Isolation Seal Rheodyne Port Adapter 77 ValvTool 087-U Order: Technical Service: Web: Rotor Seal Needle Guide P RheBuild Kits These kits include all of the tools and parts you need to repair your Rheodyne injector. The parts included are those most likely to be damaged, worn, or lost. Kits for front-loading injectors include: rotor seal, stator face assembly, isolation seal, needle guide, needle port cleaner, hex keys, operating instructions, and a mini-manual. Parts may vary, depending on valve model. VALVE MODEL CAT. NO. PRICE 7/7i/7-08/7i with stator 00 7/ / /90 TPMV 09 77/77i/ TPMV Series /8 00-U 900/ /9 0 97/97i/ TPMV Series KITS FOR SupelPRO/LabPRO UNITS Injector with Purge 98-U -Channel Selector 9-U Column Selector 88-U -Port/0-Position 7-U -Position, -Port 9-U -Position, 0-Port 9-U Solvent Selector, /" 9-U Solvent Selector, /8" 9-U Low Pressure Switching, /" 90-U Either stainless steel or PEEK unit. Rhedyne Fittings 8 87 P Nuts, /" (pk. of 0) 8 Long Nuts, /" (pk. of 0) 87 Extra Long Nuts, /" (pk. of ) 887 Ferrules, /" (pk. of 0) 88 Fitting Set, /8" ( nut, ferrule) 779 Ferrules, /8" (pk. of ) 780-U RheFlex PEEK Fittings For Rheodyne valves. Hold to 000psi/0kg/cm². /" RHEFLEX FITTING SETS Long Fitting Sets ( nuts, ferrules) 790-U Short Fitting Sets ( nuts, ferrules) 79 /" Ferrules (pk. of ) 79 /8" RHEFLEX FITTING SETS Fitting Set ( nut, ferrule) 777 Rheodyne ph Upgrade Kits Enables you to use your Rheodyne injector with samples at ph 0-. Includes Tefzel rotor seal, hex keys, instructions. VALVE MODEL CAT. NO. PRICE 7000/700/ / /8 07 P0008
8 Low Pressure Valves, Micro Valves U P Rheodyne Model 0 Low Pressure Mobile Phase Selection Valve Draw the mobile phase you need simply by rotating a switch. This zero dead volume, 7-port -position rotary valve operates to 00psi (kg/cm²). Inert Teflon tubing (0.8mm ID) ensures contaminant-free mobile phases. Model 0 Valve 889 Mounting Bracket for 0/00 70-U P0007 Rheodyne Model 00 Low Pressure Sample Injection Valve A Teflon, fixed volume loop injector with 0.8mm/0.0" ID flow Model 00 Injection Valve 88 SAMPLE LOOPS 0.mL 780-U ml 78 ml 78 0mL 78 P0009 Upchurch Micro-Valves Inert PEEK construction P000 Flow rates as low as.µl/minute (water) /-8 or 0- /" fittings SPECIFICATIONS Internal Volume /-8 valves:.µl fully opened;.µl closed. 0- valves:.8µl fully opened;.µl closed. 0-/- valves..µl fully opened;.µl closed. Thru-Hole 70-U: 0.00 all others: 0.00 Pressure Rating low pressure valves: 800psi ( bar). high pressure valves: 000psi (8 bar). P0008 MICRO-METERING VALVE (LOW PRESSURE) /-8 Flangeless Fittings Fingertight Fittings 07 MICRO-SPLITTER VALVE (LOW PRESSURE) /-8 Flangeless Fittings Fingertight Fittings 09 MICRO-SPLITTER VALVE (HIGH PRESSURE) 0- Fingertight Fittings 79-U x 0-, x -* Fingertight Fittings 70-U REPLACEMENT FITTINGS /-8 Flangeless Fittings Nuts & Ferrules ( each) 88 Ferrules (pk. of 0) 700-U Fingertight Fittings 0- (pk. of 0) 07-U passages. Operates to 00psi (kg/cm²). Supplied with a 0.mL - (pk. of 0) 00 sample loop and a female Luer adapter for a Luer tip syringe. * For capillary tubing. Order: Technical Service: Web:
9 9 Priming Valves, Gauge Kits, SSI Valves, Pulse Damper 9-U OPTI-PRIME Priming Valve for Waters Pumps Makes priming Waters pumps a convenient, one hand operation. Replaces Waters priming system. P000 OPTI-PRIME Priming Valve 9-U Priming Valve with Safety Syringe 9 Safety Syringe 9 Two-Way Shut-Off Valve Three-Way Stream-Splitting Valve P0008 Order: Technical Service: Web: U SSI Three-Way Stream-Splitting Valve Each port in this valve can be connected to pressure, as in P0000 SSI Prime/Purge Valve stream-splitting, or when connecting an in-line pressure gauge (open valve to read pressure, seal off to prevent contamination). The drain port in this valve is incorporated into the valve stem, The side vent model can replace the injector bypass valve on eliminating the need for extra tubing and fittings. A luer taper on Altex, LDC, Perkin-Elmer, Spectra-Physics, or other chromatographs, and is recommended for all general applications. The the valve stem accepts a luer syringe for priming. Valve shutoff is provided by a soft-seal tip that withstands back pressures to bottom vent model replaces the bypass valve on a Varian psi (0kg/cm²). Only Teflon, Tefzel, and stainless steelchromatograph. For /" tubing; /-8 (SSI style) fittings come in contact with the mobile phase. Order /" SSI nuts andincluded. Rated to,000psi (0kg/cm ). ferrules separately. SSI Prime and Purge Valve 890-U Upchurch Prime/Purge Valve Automatic valve operation with a simple twist of the Luer-Lock syringe. Easy installation, long seal life. Upchurch Prime/Purge Valve for Waters Pumps 7-U Upchurch Universal Prime/Purge Valve (/ - 8 fittings) 78-U SSI Two-Way Shut-Off Valve For /" tubing; /-8 (SSI style) fittings included. Rated to,000psi (0kg/cm ). Two-Way Shut-Off Valve 8789 Three-Way Stream-Splitting Valve Side Vent 879 Bottom Vent 879 SSI LO-Pulse Damper A pulse damper controls pump pulsations for a more stable baseline. The LO-Pulse damper is a patented unit compatible with single piston reciprocating HPLC pumps (Altex 0A, Eldex pumps, LDC Mini-Pump VS, SSI Models 00 and 00, etc.). At pressures from 00psi to 000psi (-0kg/cm²), it improves precision of quantitative analyses and detection limits for trace sample components. Fittings and instructions included. SSI Pressure Gauge Kits Pulse Damper 8 Pulse Damper without Cabinet 8 Components already assembled, ready for easy installation. - Backed by a three-year warranty, these highly accurate (±.%), glycerine-filled gauges have a /"/.cm face and /" NPT connection. To resist corrosion, the one-piece case and socket and the bourdon tube are made of stainless steel. All fittings and SSI tee are included psi/0kg/cm² 8-U 0-000psi/0kg/cm² 8
FITTINGS, LOOPS, AND VALVE ACCESSORIES
FITTINGS, LOOPS, AND VALVE ACCESSORIES Fittings Rheodyne offers a variety of fittings. They differ in material of construction, tubing size, and pressure rating. Materials/Biocompatibility. 316 stainless
More information78 동방하이테크상사 T.(02) F.(02)
78 동방하이테크상사 http://www.allpump.co.kr T.(0)7-9 F.(0)7-9 00--7 Introduction to Introduction Rheodyne valves fit virtually any high-pressure flow control application. As you ll see from the table below and
More informationHigh Pressure Valves. MX Series II Modules Manual Sample Injection Switching
High Pressure Valves MX Series II Modules Manual Sample Injection Introduction to High Pressure Valves HIGH Pressure Valves High Pressure Valves Introduction Rheodyne valves fit virtually any flow control
More informationHIGH PRESSURE SWITCHING VALVES
HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available
More informationInstrument Accessories & Parts, Tubing & Connections
Instrument Accessories & Parts, Tubing & Connections ASI Piston Seals for Agilent HPLC Systems Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed
More informationChrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter
HPLC ACCESSORIES IDEX Injection Valves IDEX Injection Valves Manual IDEX MANUAL INJECTION VALVES DESCRIPTION POS. SENSING SWITCH MAX PSI FITTING HIGH PRESSURE, ANALYTICAL (accepts a 22 gauge needle) FITS
More informationVALVES NEW MANUAL INJECTOR RHEBUILD KITS SAMPLE LOOPS MICRO VALVES PAGE 132 PAGE 136 PAGE 139 PAGE
VALVES NEW MANUAL INJECTOR PAGE RHEBUILD KITS PAGE 6 SAMPLE LOOPS PAGE 9 MICRO VALVES PAGE 6 SEE STARRED PRODUCTS FOR TOP SELLERS! Valve Overview VALVES 5 Rotary Shear Valves Rheodyne Rotary Shear Valves
More information98 동방하이테크상사 T.(02) F.(02)
98 동방하이테크상사 http://www.allpump.co.kr T.(0)57-69 F.(0)57-69 00--7 troduction to Upchurch Scientific Valves Valves troduction Valves jection and Selection Valves for Pressures to,000 psi (69 bar) Switching
More informationHigh Pressure Valves. MX Series II Modules Manual Sample Injection Switching
High Pressure Valves MX Series II Modules Manual Sample Injection Switching Introduction to High Pressure Valves HIGH PRESSURE VALVES High Pressure Valves Introduction Rheodyne valves fit virtually any
More informationApplication Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!
Inlet Solvent Filters Filters and Degassers General Use Inlet Solvent Filters Large Surface Areas disposable µm, 0 µm, and 0 µm Pore Sizes Available General Use and Prep Filters for Higher Flow Applications
More informationseal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271
Restek Replacement Parts for Agilent HPLC Systems Meet or exceed OEM performance. Agilent part # qty. cat.# price Preventive Maintenance Kit Includes: rotor seal, needle seat, needle assembly, seat cap
More informationFittings SECTION 1 OF 4 SECTIONS ON FITTINGS
Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Deburring an Upchurch Scientific fitting in Oak Harbor, WA. The Very High Pressure (VHP) reusable fitting, VHP-320, is one of the exciting new products in the
More informationUpchurch High Pressure Fittings & Connectors
.010 thru-hole P-742 PEEK ZDV Union. 9 2.050 thru-hole P-760 PEEK ZDV Union P-704 PEEK ZDV Union. 9 2. 9 2 Fingertight Fittings ONE-PIECE FINGERTIGHT FITTINGS INTRODUCTION For Coned Ports For convenience
More informationOne-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.
Fingertight Fittings 4 One-Piece Fingertight Fittings Upchurch Scientific s original One-Piece Fingertight Fittings have 0-3 threads and are designed to be used with /6 OD tubing, except the M-645 (6-40,
More informationÄKTA system Training Guide. Purifier 100 / 10. amersham bio science
ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bio science ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector
More informationUltra High Performance Fittings. Fittings Connectors Kits
Ultra High Performance Fittings Fittings Connectors Kits Ultra High Performance Fittings Introduction Ultra Performance Fittings Introduction high Temperature Versions Withstand Temperatures up to 200ºC
More informationAgilent 1200 Series Manual Injector
Agilent 1200 Series Manual Injector User Manual 1200 Series MI User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006, 2008 No part of this manual may be reproduced in any form or by
More informationGLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913
GLENCO Syringes As a complement to the Spectra/Chrom chromatographic products, Spectrum manufactures precision syringes for sample injection and collection. These syringes are designed specifically to
More informationÄKTA system Training Guide
ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector
More informationVERITY Purification Systems Build the perfect system to fit your research
VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC
More informationPrimeLine TM HPLC Pumps
PrimeLine TM HPLC Pumps Isocratic Model 501 Gradient System 500G PrimeLine TM Isocratic and Gradient HPLC Pumps Feature: Self-priming pump head requires no manual priming Patented Floating Pump Seal design
More informationFixed Flow Splitter *
Fixed Flow * *Patent Pending Analytical Scientific Instruments Fluid resistor technology eliminates tedious adjustments to capillary tubing to change split ratios. Easy to use interchangeable fluid resistors
More informationAgilent G4239C Valve Kit - Instructions
Agilent G4239C Valve Kit - Instructions Agilent G4239C Valve Kit - Instructions Technical Information about the Agilent Valve Kit G4239C. Contents Typical Applications 2 Multicolumn Selection 2 Method
More informationCHROMATOGRAPHY. SYKAM S 6000 Valve Series
CHROMATOGRAPHY SYKAM S 6000 Valve Series Version: March 2011 SYKAM S 6000 Valve Series Rotor Seals Sykam offers a variety of different Rotor Seals materials to satisfy any possible application. All materials
More informationFilters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159
Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 156 Inlet Solvent
More informationAgilent 1260 Infinity Manual Injector
Agilent 1260 Infinity Manual Injector User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006-2011, 2012 No part of this manual may be reproduced in any form or by any means (including
More informationLiquid Chromatography LC Consumables SSI-LC
Liquid Chromatography LC Consumables SSI-LC-10-2017 Table of Contents HPLC Pumps...3 LC-30AD... 3 LC-20AD / LC-20AB / LC-20ADXR... 4 LC-20AT... 4 LC-20Ai... 5 LC-10ADvp... 5 LC-10ATvp... 6 LC-10Ai... 6
More informationS 1125 HPLC Pump System
Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make
More informationQuickSplit TM Flow Splitters
Quick TM Flow ters Quick TM Flow ter Features: Fluid resistor technology eliminates tedious adjustments to capillary tubing for split ratio optimization ratios are stable and reproducible, and not affected
More informationAgilent G5632 Valve Kit Instructions
Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Contents Typical Applications 2 Alternating Column Regeneration (2 position/10 port valves only) 2 Dual column selection 3 Sample
More informationAgilent InfinityLab Quick Change Valve G4237A
Agilent InfinityLab Quick Change Valve G4237A Instructions Agilent G4237A Valve Kit Instructions This technical note describes the installation and application of the Agilent InfinityLab Quick Change 4
More informationMobile Phase Accessories
NEW! Now available for GL-45 bottles! Bottles not included Waste Overflow Indicator Avoid messy pooling around mobile phase waste containers. Audible alarm instantly alerts user, preventing overflow. Compact,
More informationAgilent Valve Kit G4231A/B/C and G4232B/C/D
Agilent Valve Kit G4231A/B/C and G4232B/C/D Instructions Agilent Valve Kit G4231A/B/C and G4232B/C/D - Instructions This Technical Note describes the installation of the Agilent G4231A/B/C and G4232B/C/D
More informationHPLC Tubing and Fittings Hints & Tips for the Chromatographer
HPLC Tubing and Fittings Hints & Tips for the Chromatographer By William S. Letter (Chiralizer Services, L.L.C.) INTRODUCTION: Setting up a high pressure liquid chromatography (HPLC) system to run trouble-free
More informationHPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.
1. Overview The front panel houses the UV detector lamp switch, Rheodyne injection valve, prime/purge valve, pressure gauge, and the storage compartment. In the storage compartment are the LED display
More informationHPLC Accessories. HPLC Columns HPLC Applications
HPLC Accessories Instrument Replacement Parts..........................332-337 Filters, Mobile Phase Accessories........................338-342 Column Heaters, Gas Trapping Systems......................343
More informationThis convenient system is made entirely of inert parts: glass, Baseline drift
95 P000515 55020 9960342 Supelco Mobile Phase Degassing System 55060-U Eliminates: Flow instabilities Mobile Phase Reservoir System Detector noise This convenient system is made entirely of inert parts:
More informationAdjustable Flow Splitter *
Adjustable Flow Splitter * *Patent Pending Analytical Scientific Instruments Adjustable metering valve enables precise direct control over split ratios. Fluid resisr technology eliminates tedious adjustments
More informationHyperShear TM HPLC and UHPLC Mixers
HyperShear TM HPLC and UHPLC s Reduce baseline noise, increase sensitivity and improve gradient accuracy Decrease mixing and delay volume without sacrificing mixing efficiency Increase reaction efficiency
More informationPolymeric Fittings Low Pressure
INDEX PPS Nuts for Flat Bottom Fitting Details 59 PEEK Flangeless Nuts 62 Polyacetal Color Coded Flangeless Nuts 63 Polypropylene Flanged Fingertight Nuts 64 Unions 65 Bulkhead Unions 67 PEEK Tees, Crosses
More informationAgilent InfinityLab Quick Change Valves G4231A/C and G4232C/D
Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D Instructions Agilent Valve Kit G4231A/C and G4232C/D - Instructions This technical note describes the installation and application of the Agilent
More informationInstallation of the 2 position/10 port valve into the 1100 series thermostatted column compartment
Agilent G1316A Thermostatted Column Compartment Technical Note Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment System Requirements 2 Performance Specifications
More informationAgilent SD-1 Purification System ml/min
Agilent SD-1 Purification System - 200 ml/min Introduction Installation of the Capillary Kit This technical note shows you how to install the Stainless Steel Capillary Kit (SD- 1 Purification System -
More informationGE Healthcare. Valve INV-917. Instructions
GE Healthcare Valve INV-917 Instructions INV-917 2 1 3 7 4 5 6 Important user information All users must read this entire manual to fully understand the safe use of Valve INV-917. Important! Valve INV-917
More informationMaintaining Your Agilent 1100 Series HPLC System
Operate your lab at peak performance Troubleshoot difficult problems Select the right Agilent supplies For detailed information about supplies from Agilent, please contact your local Agilent sales representative,
More informationAgilent Valve Kit G4231A/B and G4232A/B/C
Agilent Valve Kit G4231A/B and G4232A/B/C Instructions Contents Typical Applications 2 Dual column selection (G4231A/B or G4232A/B/C) 2 Sample enrichment and sample cleanup (G4231A/B or G4232A/B/C) 2 Alternating
More informationValving Schemes for the BioLogic Duo-Flow Chromatography System
Valving Schemes for the iologic Duo-Flow Chromatography System table of contents pplication asic ion Valve Operation using,, and Purge Positions position is for filling a loop with sample or for running
More informationQuick Reference Guide. Supplies for Waters HPLC Systems
Quick Reference Guide Supplies for Waters HPLC Systems works with WATERS SHIMADZU THERMO/DIONEX BRUKER/VARIAN PERKINELMER CTC MORE Put innovation and quality to work on a wide range of GCs and HPLCs in
More informationHyperShear TM HPLC Mixers
HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex shear mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume
More informationIDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159
Filters & Frits Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159
More informationMicrosep Low-Bleed PTFE-Lined Septa. XLB Septa
Septa Chromatogram Cross Reference Guide Actual Size Drawing Measurement 1/4" (6mm) Shimadzu*, SRI* Chromatographs 3/8" (9.5mm) 7/16" (11mm) Antek, Finnigan 9100, 9600, Gow- Mac, Agilent 5700, 5880 & 5900,
More informationPhysiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN
80-6000-32 Physiological Calibration Standard II 80-2037-62 Calibration standard physiological fluid 80-2037-61 CALIBRATION STANDARD PROTEIN HYDROLYSATE 80-2104-53 1/8" FLANGELESS FITTING (PK 5) 80-2108-41
More informationUsing a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application
Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville
More informationHyperShear TM HPLC Mixers
HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex sheer mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume
More informationNEW? HPLC ACCESSORIES. What s. look for this circle
HPLC ACCESSORIES Instrument Accessories & Parts..............327-332 Tubing & Connections.......................332-335 Tools & Maintenance.........................336-337 Mobile Phase Accessories Bottle
More informationNEW HPLC - SYSTEM LINE
NEW HPLC - SYSTEM LINE S c h a m b e c k S F D G m b H Drieschweg 13A D-53604 Bad Honnef/Germany Phone: +49 2224 9239-0 E-Mail: info@schambeck-sfd.com Internet: www.schambeck-sfd.com S 9425 HPLC solvent
More informationG1160A Agilent 1100 Series Multiple Purpose Switching Valve
G1160A Agilent 1100 Series Multiple Purpose Switching Valve Description: The G1160A Agilent 1100 Series Multiple Purpose Switching Valve is a stainless steel 12-position, 13-port motorized valve operated
More informationAgilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve
Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Technical Note This Technical Note describes the purpose, installation, and configuration and use of a diverter valve
More informationLC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation
LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL 1993 Dionex Corporation Document No. 034859 Revision 02 September 1993 1993 Dionex Corporation All rights reserved worldwide Printed in the United States
More informationcheminert fittings Low Pressure Flangeless Tube End Fittings Flangeless tube end fittings 1/4-28
Low Pressure Flangeless Tube End Fittings Cheminert low pressure fittings are ideally suited for flow injection analysis, low pressure liquid chromatography, and stream sampling devices. They may be safely
More informationReciPro Liquid Metering Pumps. Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options
ReciPro Liquid Metering Pumps Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options ReciPro HP Series Eldex metering pumps can be used wherever precise flow rate
More information(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 .
Low Pressure FITTINGS & CONNECTORS Dimensions for /4-8 Upchurch Scientific eliminate the need to flange. This removable and reusable system provides several benefits: (pages 58 and 59) Convenience: Our
More informationSTI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Extended range HPLC has been investigated for many years; however, progress was delayed because of
More informationLiquid Chromatography
SCINTOMICS Liquid Chromatography Always the right system for your needs. SCINTOMICS: Always the right system for your needs Advanced Research Daily QC Routine and beyond High Performance analytical/semi-preparative
More informationTZ Rotor Seal for PEEK Stator for SS Stator for 7010 with MBB Parts for Knob
Item Number Description 0241-071 TZ Rotor Seal for 7010-083 0341-043 PEEK Stator for 9010-060 0341-117 SS Stator for 7010 with MBB 0341-157 Parts for 7010-110 0441-015 Knob Assy for 7000 0441-079 SS Stator
More informationTECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure
TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like
More informationTechnical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer
Technical Offer Antek Model 6200 Analyzer 2015.4 Determine Total Sulfur and Total Nitrogen in a single analyzer Meet sulfur regulations and control your process with continuous sulfur and/or nitrogen measurements
More informationAgilent 1200 Series Valves
Agilent 1200 Series Valves User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including electronic storage and
More informationHPLC Essentials Genuine Restek Replacement Parts for HPLC Systems
HPLC Essentials Genuine Replacement Parts for HPLC Systems 20 YEARS Turning Visions into Reality 800-356-1688 814-353-1300 2 Becky Wittrig HPLC Products Marketing Manager 4+ years of service! did you know?
More informationHPLC SYSTEM S 500 SERIES
HPLC SYSTEM S 500 SERIES The Sykam HPLC System S 500 Series is intended for all routine analysis as well as for the ambitious analyst. The system configuration is highly variable and several upgrade options
More informationHyperShear TM HPLC and UHPLC Mixers
HyperShear TM HPLC and UHPLC s HyperShear TM HPLC and UHPLC Features: Micro Flow, Low Flow, Analytical Flow, High Flow and Combo Series Reduce baseline noise, increase sensitivity and improve gradient
More informationHPLC System S 600 Series
HPLC System S 600 Series The Sykam HPLC System S 600 Series is intended for the ambitious analyst. The system configuration is highly variable and several upgrade options make this system suitable for
More informationRHEODYNE Ersatzteil-Liste 2011
0241-007A 2/6 Man Inj, SS w/ss Bearing 0241-071 TZ Rotor Seal for 7010-083 0341-043 PEEK Stator for 9010-060 0341-117 SS Stator for 7010 with MBB 0341-157 Parts for 7010-110 0441-015 Knob Assy for 7000
More informationSimplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.
Simplify your search for COLUMN HARDWARE Discover how to maximize results with Isolation Technologies column hardware and accessories that are specifically engineered to meet critical UHPLC, HPLC, and
More informationFLUIDICS FITTINGS. 32 CONED FITTINGS 39 FLAT-BOTTOM FITTINGS 48 MarvelX 50 FITTINGS TOOLS 56 LARGE BORE FITTINGS 57 VHP FITTINGS 61 FITTINGS KITS
30 FITTINGS We offer a wide and diverse selection of fittings to meet your system requirements. A fitting refers to a complete product ready to assemble and connect tubing into a part. This could be a
More informationKEY FEATURES. Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups
CapTite Microfluidic Construction Kits KEY FEATURES Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups Routing fluids can be one of
More informationGENERAL CATALOG L.TEX CORPORATON
GENERAL CATALOG L.TEX CORPORATON 1/8 동방하이테크상사 http://www.allpump.co.kr T.(02)457-6292 F.(02)457-6293 13-12-01 L. Tex Corporation was established in March 2001 to design, develop and manufacture the versatile
More informationGAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS
GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour
More informationSetting up SilFlow for BackFlush in your GC
Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile
More informationMotor Valve MV-7/IMV-7
Motor Valve MV-7/IMV-7 INSTRUCTIONS 1. Introduction Motor Valves MV-7/IMV-7 are a 3-position, 7-port motorized valves designed to he used as automatic sample injection valves or system valves. The valves
More informationAgilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet
Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet 1. Description The Agilent Dynamax modular HPLC column system uses a unique technology, Dynamic, to maintain the structure of the packed
More informationSELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS
Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in
More informationCTC Analytics Service Note June 2015 PAL-xt: Material change for Rotor Seal of C2V-3006-CTC
To: Dealer/OEM orld-ide, PAL Systems Platform PAL and PAL-xt Systems From: Toni Eberwein Date: June 19, 2015 Subject: change for rotor seal C2-30R (for valve C2V-300D-CTC) CTC Alytics Service Note June
More information850 Professional IC. AnCat MCS Manual EN
850 Professional IC AnCat MCS 2.850.3030 Manual 8.850.8052EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com 850 Professional IC AnCat
More information845Z Injection Module User s Guide
845Z Injection Module User s Guide LT2575/ 2004 Gilson, Inc. All rights reserved May 2004 Table of Contents Declaration of Conformity 1 Introduction 2 Installation 3 Operation 4 Maintenance Unpacking...
More informationPrecision Sampling Catalog
Precision Sampling Catalog Syringes for Chromatography CATALOG 07 INT Syringe Features Mininert Valv alves 2-5 28-29 Gas/Liquid Syringes Probes 6-14 30-31 Liquid Syringes 14-23 Automated Liquid Handling
More information[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE
WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION Waters Advanced Purification (AP) series of glass columns are constructed of biocompatible glass and polymeric materials and can be easily used with
More informationPrecision Sampling Catalog
Precision Sampling Catalog CATALOG 06 INT Contents SYRINGE FEATURES Pressure-Lok syringe features... page 2 Special features of select models... 3 Gas/liquid and liquid syringe features... 4-5 GAS/LIQUID
More informationGlycoChrom TM HPLC Analyzer. Hardware Installation and System Test
GlycoChrom TM HPLC Analyzer Hardware Installation and System Test PIN 410-5004 For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-8 00-424-6723) ,, Table of Contents
More informationSelecting The Appropriate INLET LINER
Selecting The Appropriate INLET LINER Don t Let The Quality of Your Inlet Liner Limit the Efficiency of Your GC System. ANALYTE ANALYTE CONCENTRATION THERMALLY LABILE HIGH Liners for SPME SPME LOW (TRACE)
More informationAgilent 218 Purification Solution
Agilent 218 Purification Solution System User Guide Purification Solution System User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2012, 2013 No part of this manual may be reproduced in
More informationUsing the PSD for Backflushing on the Agilent 8890 GC System
Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped
More informationConnectors & Connectors with valves
Connectors & Connectors with valves Inside... Omnifit Cap instructions... Small Bore Connectors... 3 with valves... Large Bore Connectors... 5 with valves... 5 T Block Connector... 6 In-line Connectors...
More informationPage 1. Alternate Carrier Gas Considerations and Faster GC Analysis
Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down
More informationChoose for Your Instrument. GC Supplies - Bruker (Varian) Instrument Quick Pick Guide
Choose for Your Instrument GC Supplies - Bruker (Varian) Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Your chromatography analysis
More informationGas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593
Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent
More informationLC Accessories Instrument Replacement Parts For Agilent HPLC Systems For PerkinElmer HPLC Systems For Shimadzu HPLC Systems...
LC Accessories Instrument Replacement Parts For Agilent HPLC Systems...299 302 For PerkinElmer HPLC Systems...303 For Shimadzu HPLC Systems...304 305 For Thermo HPLC Systems...306 For Waters HPLC & ACQUITY
More informationACQUITY UPLC I-Class System with 2D Technology
ACQUITY UPLC I-Class System with 2D Technology The Waters ACQUITY UPLC I-Class System with 2D Technology allows chemists to increase sensitivity and selectivity, eliminate unwanted interferences, characterize
More informationMET-Biodiesel Capillary GC Columns
MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What
More informationAchieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)
Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Bill Wilson and Chin-Kai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington,
More information