Sample Pretreatment, Accessories

Size: px
Start display at page:

Download "Sample Pretreatment, Accessories"

Transcription

1 11 Sample Pretreatment, Accessories Sample pretreatment Column protection ~147 Tubing parts ~151 Empty columns and other parts ~155 Pressure resistant empty glass columns , 157

2 11 Sample pretreatment, Accessories Material properties of products Stainless (SUS-316) A general-purpose material for general HPLC products. Contains Ni, Cr, Mo, etc, as well as Fe, and is highly resistant to corrosion. Polyacetal An engineering plastic. A polymer in which aldehyde compounds are polymerized, with excellent chemical resistance and excellent machinability. PEEK (polyetheretherketone) A super engineering plastic developed as an alternative to metals. A polymer containing ketones and ether bonds, it is highly resistant to pressure, chemicals, heat, and fatigue. Used as an alternative to stainless for a metal-free tubing system. Polypropylene A polymer of propylene. Excellent chemical and heat resistance. Often used for containers since processing, such as injection molding, is easy. Teflon (polytetrafluoroethylene, PTFE) A polymer of tetrafluoroethylene. Highly resistant to chemicals but not so resistant to pressure as PEEK. Generally used for low pressure tubing systems. (Teflon is a trademark of DuPont.) Sample pretreatment Sample pretreatment cartridge YMC Dispo SPE Disposable type cartridge made from polypropylene Utilizes packing material designed for HPLC columns, manufactured under strict quality controls Excellent cartridge-to-cartridge reproducibility High recovery of samples Method of use YMC Dispo SPE Vacuum Syringe Adapter YMC Dispo SPE Excellent recovery YMC Dispo SPE Sample YMC Dispo SPE Cartridge, Company A Cartridge, Company B Basic sample (Propranolol hydrochloride) 89(99)% 59(73)% 66(89)% Acidic sample (Thioctic acid) 91(100)% 92(89)% 87(88)% *Figures inside parentheses represent recoveries obtained when buffer was used. Container Made from medical-grade polypropylene with minimal elution of additives. Upper and lower frits Pore size of 20 µm Solid phase YMC*GEL Vacuum method Compression method Centrifugation Vacuum method is suitable for large-scale treatment and compression method is suitable for small-scale treatment YMC Dispo SPE C18 XQSPEC18101 XQSPEC18203 XQSPEC18503 XQSPEC18A06 YMC Dispo SPE SIL C18 100mg/1mL 100-pack C18 200mg/3mL 50-pack C18 500mg/3mL 50-pack C mg/6mL 30-pack Luer tip Can be connected to commercially available vacuum solid phase extraction systems. XQSPESIL503 XQSPESILA06 SIL 500mg/3mL 50-pack SIL 1000mg/6mL 30-pack 144

3 Column protection Stainless steel precolumn filters are convenient for the case shown below: One of the causes of a gradual increase of a column pressure after each sample injection is that fine particles in the sample clog the frit of the column. Replacing the column frit is one solution; however it is more convenient to use precolumn filter. Connect a precolumn filter between the injector and the column, check the line pressure occasionally, and replace the precolumn filter when the line pressure increases. Stainless steel precolumn filters are suitable for stainless steel tubing systems. Both PEEK and stainless steel precolumn filters are suitable for PEEK tubing systems. Problem prevention High-molecular weight compounds (proteins, DNA, sugars, etc.) that easily and irreversibly adsorb to the main column are likely to cause a pressure increase and separation failure. When these compounds adsorb to the main column, it is difficult to recover column performance by cleaning. A guard column will protect the main column when fouling of the main column is due to contamination from sample matrices. YMC-Pack YMC guard cartridges Precolumn filter Stainless steel precolumn filter Filter construction with minimal dead volume Effective diameter of the filter is extremely small about 1.6 mm. Sample diffusion that occurs in passage is minimized. Stainless steel precolumn filter Filter XRPRCS02 XRPRCS25 For tubing system with 1/16 outer diameter, 1 filter included 5 spare filters 2 μm are included Retainer There is no decrease of column efficiency due to connection of a precolumn filter. Main column only Theoretical plate number (peak 4): 11,200±200 (n=3) Pressure (MPa) : 5.4±0 (n=3) PEEK precolumn filter Metal free The material of the wetted part of the holder is PEEK and the packing is PCTFE. The packaging that of the filter is a mixture of PEEK and Teflon. PEEK precolumn filters are suitable for use in HPLC systems requiring a metal-free environment. High-pressure resistance PEEK precolumn filters are resistant to ca. 35 MPa. PEEK precolumn filter min After connection of a precolumn filter Theoretical plate number (peak 4): 11,500±300 (n=3) Pressure (MPa) : 5.4±0 (n=3) min Column : YMC-Pack ODS-A (5 μm, 120 Å) 150 X 4.6 mmi.d. Eluent :acetonitrile/water (60/40) Flow rate : 1.0 ml/min Temperature :37 C Detection : UV at 270 nm, 0.32 AUFS Sample : 1. Uracil (0.05 mg/ml) 2. Methyl benzoate (0.5 μl/ml) 3. Butyl benzoate (1.5 μl/ml) 4. Butylbenzene (12.0 μl/ml) Filter XRPRCP02 XRPRCP25 For tubing systems with 1/16 outer diameter, 1 filter included 5 spare filters 2 μm are included 145

4 11 YMC guard cartridges Wide variety of packing materials YMC*GEL with various functional groups identical to those available for analytical columns is packed under high pressure. Disposable The cartridge holder can be used repeatedly. Only the cartridge column needs replacement when worn out. Easy cartridge replacement The main body of the YMC guard cartridge is composed of a cartridge holder and a cartridge column. The cartridge column is threaded for easy replacement. cartridge holder column coupler cartridge column Cartridge Column Product number inner diameter X length (mm) 1/pack 5/pack 1.0 X GC GC 2.1 X 10-01Q1GC-1-01Q1GC 3.0 X GC GC 4.0 X GC GC 1.0 X GC GC 2.1 X 20-02Q1GC-1-02Q1GC 3.0 X GC GC 4.0 X GC GC A cartridge holder will need to be purchased separately before using this product for the first time. Cartridge Holder Set cartridge holder set (10 mm length) XPGCH-Q1 cartridge holder set (20 mm length) XPGCH-Q2 Cartridge holder set includes a cartridge holder (1 set), and a column coupler. Guard cartridge column for semi-preparative cartridge holder Pressure resistance up to 30 MPa (4350 psi) Ideal for protecting semi-preparative column Cartridge Column (2/pack) inner diameter X length (mm) Product number CC CC CC A cartridge holder will need to be purchased separately before using this product for the first time. Cartridge Holder cartridge holder (inner diameter : 10 mm) cartridge holder (inner diameter : 20 mm) cartridge holder (inner diameter : 30 mm) XPCHSPW1 XPCHSPW2 XPCHSPW3 cartridge column * Please refer to the page of each product for product number. Example) Triart C18 (5 μm, 120 Å) = TA12S05 146

5 Guard cartridge column for UHPLC High Pressure resistance up to 100 MPa (15,000 psi) Low-volume, low-dispersion cartridges minimize the impact on separation Zero-dead-volume direct connection to column Hand-tight guard replacement (No tools required) EXP Guard cartridge holder Low-volume, low-dispersion cartridges minimize the impact on separation mv With guard cartridge 50 N4 = 19,200 Main column only 0 N4 = 19, min 4 Column : YMC-Triart C μm 100 X 2.0 mmi.d. Eluent :acetonitrile/water (60/40) Flow rate : 0.4 ml/min Temperature :25 C Detection : UV at 270 nm Injection :1 μl Sample :1. Uracil 2. Methyl benzoate 3. Naphthalene 4. Butyl benzoate EXP cartridge column EXP guard cartridge column with low-volume and low-dispersion column minimize the impact on separation. EXP guard cartridge column provides less than 3% decrease in theoretical plate count. EXP Cartridge Column (Max. pressure: 100 MPa, 3/pack) Particle size 1.9 μm inner diameter X length (mm) Product number Triart C18 Triart C8 ExRS Triart C8 Triart Phenyl Triart PFP 2.1 X 5 TA12SP9-E5Q1CC TAR08SP9-E5Q1CC TO12SP9-E5Q1CC TPH12SP9-E5Q1CC TPF12SP9-E5Q1CC 3.0 X 5 TA12SP9-E503CC TAR08SP9-E503CC TO12SP9-E503CC TPH12SP9-E503CC TPF12SP9-E503CC EXP Guard Cartridge Holder (Adjustable ferrule, Max. pressure: 137 MPa) EXP direct connect holder (for both 2.1 mm and 3.0 mm inner diameter, 2 titanium hybrid ferrule and 1 nut included) XPCHUHP Fitting for Connecting System and Main Column/Guard Cartridge (Adjustable ferrule, Max. pressure: 137 MPa) Hand-tight EXP fitting (Hand-tight nut and titanium hybrid ferrule included) Fitting for connecting system and main column/guard cartridge is also available. Replacement Ferrule Titanium hybrid ferrule (5/pack) XRHTF-01 Hand-tight EXP fitting XRHTF-05 *EXP is a registered trademark of Optimize Technologies, Inc. 147

6 11 Tubing parts Universal connector Enables perfect column connectivity A movable ferrule and a fixing screw enable secure connection to the column endfitting. There is no cavity at the top of the ferrule. Super high-pressure resistance Universal connectors are high performance connectors resistant to high pressure up to 70 MPa when tightened only by hand. For connection to a guard column The double type is the most suitable for connecting of a main column and a guard column. Double type Single type Fixing screw Fixing ferrule Quick, easy and secure connection. No tools required. Adjuster screw Sealing ferrule (replacable) Tightening the fixing screw forces a tube to squeeze into the column as far as it will go, and the tube makes tight contact with the screw hole. The tube makes tight contact with the screw hole by tightening a fixing screw. Universal connector (single) XRSFS520 1/16 outer diameter, inner diameter, 20 cm length XRSFS220 1/16 outer diameter, inner diameter, 20 cm length Universal connector (double) XRSFD506 1/16 outer diameter, inner diameter, 6 cm length XRSFD510 1/16 outer diameter, inner diameter, 10 cm length XRSFD520 1/16 outer diameter, inner diameter, 20 cm length XRSFD210 1/16 outer diameter, inner diameter, 10 cm length XRSFD220 1/16 outer diameter, inner diameter, 20 cm length Universal connector (Single flexible) XRSFS528F 1/32 outer diameter, inner diameter, 28 cm length XRSFS540F 1/32 outer diameter, inner diameter, 40 cm length outer diamater of metted part is 1/16" Spare ferrule for universal connectors XRSFV Vespel sealing ferrule, 5-pack 148

7 Handy connector 1 A ferrule integrated into a connector Handy connector 1 resists pressure to ca. 21 MPa. Handy connector 1 is suitable for tubing systems of relatively low pressure. Connection to a tubing system is easy because a ferrule is integrated into the connector. Metal free The whole connector is made from PEEK. Handy connector 1 is suitable for metal-free tubing systems using PEEK tubes. Handy connector 1 PEEK XRP0203 For tubing systems of 1/16 outer diameter, 10-pack Handy connector 2 High pressure resistance and made from stainless steel Handy connector 2 resists pressure to ca. 42 MPa. Handy connector 2 is suitable for connection to the injection side of a column, to which high pressure is applied. It is also useful for connection of a guard column or a precolumn filter. Metal free The ferrule at the wetted part of the connector is made from PEEK. Handy connector 2 is suitable for metal-free tubing systems using PEEK tubes. Ferrule is replaceable Only the ferrule needs to be replaced when it deteriorates, as opposed to the entire connector. Handy connector 2 XRP0204 For tubing system of 1/16 outer diameter, 2-pack XRP0205 Spare PEEK ferrule, 10-pack Be aware that Handy connector 2 cannot be connected to Old Shimadzu type, Old JASCO type, or Old Hitachi type tubes. Stainless steel Ferrule for replacement Quick, easy and secure connection. No tools required. (3) Turn the connector while pushing the tube to connect the tube and connector. (4) Be sure that there is no leak from the screw hole. (1) Extend the top of PEEK tube beyond the ferrule. (2) Force the tube to make tight contact with the bottom of the screw hole. 149

8 11 PEEK tubing Easy to use PEEK tubing is made from a material that is flexible and easy to use. It is easily cut using a commercially available cutting knife. A PEEK tube with an inner diameter of mm is useable at up to 40 MPa. PEEK tubes are practical general tubing as alternatives to stainless steel tubing. They are suitable for metal-free tubing systems. A Handy connector is suitable for connection of PEEK tubing to a column. Outer diameter 1/16 Inner diameter mm 0.25 mm 0.5 mm 0.8 mm Stainless steel tubing Stainless steel male nut and ferrule are used for connection Outer diameter 1/16 Outer diameter 1/8 Tube cutter For cutting 1/16 stainless tubing (simple type) Inner diameter 0.25 mm 0.5 mm 0.8 mm 2.0 mm Male nut for 1/16 tubing system (stainless steel) W type P type Old Shimadzu type Old JASCO type Old Hitachi type Female nut for 1/8 tubing system Ferrule for 1/8 tubing system Ferrule for 1/16 tubing system (stainless steel) Male nut for 1/16 tubing system Ferrule for 1/16 tubing system Female nut for 1/8 tubing system (cap nut) (stainless steel) Ferrule for 1/8 tubing system (stainless steel, double ring) Union for 1/16 tubing system Unions for 1/16 tubing system come in two types, made from either stainless steel or PEEK. They are convenient to use it with a Handy connector. Connector type is W type. Stainless steel PEEK Column coupler Column couplers are used for columnto-column connections. Various tube inner diameters and column connection types are available. Cross section 150

9 PEEK tubing Union for 1/16 tubing system XRPT01 1/16 outer diameter, mm inner diameter, 3 m length XRPT02 1/16 outer diameter, 0.25 mm inner diameter, 3 m length XRPT05 1/16 outer diameter, 0.5 mm inner diameter, 3 m length XRPT08 1/16 outer diameter, 0.8 mm inner diameter, 3 m length Stainless steel tubing XRST02 1/16 outer diameter, 0.25 mm inner diameter, 2 m length XRST05 1/16 outer diameter, 0.5 mm inner diameter, 2 m length XRST08 1/16 outer diameter, 0.8 mm inner diameter, 2 m length XRST20 1/8 outer diameter, 2.0 mm inner diameter, 5 m length Tube cutter Notes for successful tubing The shapes of separation peaks are affected not only by column performance, but by the tubing system as well. Some effort is needed to minimize the dead volume in a tubing system among the injector column and detector, in order to prevent poor peak shape. Using a tube with a small inner diameter (0.127 mm) is one solution. When a tube is connected to a union or a column, it is important to give due consideration to make the top of the tube contact flush with the bottom of the screw hole and to avoid leakage or creation of a cavity. XRP1909 For cutting 1/16 stainless tubing Male nut for 1/16 tubing system (stainless steel) XRONW 1/16 W type, P type, 5-pack XRONS 1/16 Old Shimadzu type, 5-pack XRONJ 1/16 Old JASCO type, 5-pack XRONH 1/16 Old Hitachi type, 5-pack Ferrule for 1/16 tubing system (stainless steel) XRONFA 1/16 one ring ferrule, 5-pack Female nut for 1/8 tubing system (cap nut)(stainless steel) XRON8 1/8 female nut, 5-pack Ferrule for 1/8 tubing system (stainless steel) YMC-Pack Column coupler guard cartridges (page 146) XRTWFA Front ferrule, back ferrule, 5-pack each Union for 1/16 tubing system XRUNW 1/16 tubing system (stainless steel) XRUN16P 1/16 tubing system (PEEK) Column coupler XRCP1602 1/16 outer diameter, 0.25 mm inner diameter XRCP1605 1/16 outer diameter, 0.5 mm inner diameter XRCP1620 1/16 outer diameter, 0.8 mm inner diameter (Stainless tube 50 mm 1, male nut 2, ferrule 2) 151

10 11 Empty columns and other parts 1. YMC original empty columns 2. Ferrule type empty column 3. Flange type empty column Analytical column Semi-preparative column Inner diameter 2.0~10 mm Inner diameter 20~30 mm Inner diameter 4.0~6.0 mm Inner diameter 50~200 mm YMC original empty columns (for analysis or semi-preparative isolation) A stainless steel tube with a screw and an endfitting are directly connected (screw type). Since YMC original empty columns use no ferrule, there is no danger of endfitting dislocation when the column is packed and used under high pressure. YMC original empty columns length X inner diameter (mm) XC0502WT 50 XC1502WT XC2502WT 250 XC0346WT 30 XC0546WT 50 XC1046WT 100 XC1546WT XC2546WT 250 XC3046WT 300 XC0506WT 50 XC1006WT 100 XC1506WT 150 XC2506WT XC3006WT 300 XC5006WT 500 XC0308WT 30 XC3008WT XC5008WT 500 XC0310WT 30 XC1510WT 150 XC2510WT XC3010WT 300 XC5010WT 500 length X inner diameter (mm) XC0520WT 50 XC1520WT 150 XC2520WT 250 XC3020WT XC5020WT 500 XCA020WT 1000 XCL530WT 75 XC2530WT 250 XC3030WT XC5030WT 500 XCA030WT

11 YMC original empty column parts Inner diameter 2.0 mm, 4.6 mm, 6 mm, 8 mm, 10 mm Column end assembly Frit Inner diameter 20 mm, 30 mm Column end assembly Spacer Distributor Frit YMC original empty column parts Main column part names XPEF02 XPEF46 XPEF06 XPEF08 XPEF10 XPEF20 XPEF30 For 2.0 mm inner diameter, Column end assembly, 1-pack For 4.6 mm inner diameter, Column end assembly, 1-pack For 6.0 mm inner diameter, Column end assembly, 1-pack For 8.0 mm inner diameter, Column end assembly, 1-pack For 10 mm inner diameter, Column end assembly, 1-pack For 20 mm inner diameter, Column end assembly, 1-pack For 30 mm inner diameter, Column end assembly, 1-pack XPSF02S For 2.0 mm inner diameter, Frit, 5-pack XPSF46S For 4.6 mm inner diameter, Frit, 5-pack XPSF06S For 6.0 mm inner diameter, Frit, 5-pack XPSF08S For 8.0 mm inner diameter, Frit, 5-pack XPSF10S For 10 mm inner diameter, Frit, 5-pack XPSF20S For 20 mm inner diameter, Frit, 2-pack XPSF30S For 30 mm inner diameter, Frit, 2-pack XPSS20S For 20 mm inner diameter, Spacer, 1-pack XPSS30S For 30 mm inner diameter, Spacer, 1-pack Frits with 20 mm or more inner diameter include distributors. Connector type is W type. Frit A disk type part used to keep the packing material in a column. A frit with a pore size of 2 μm is generally used for 5 μm packing material. Distributor A part used to uniformly introduce a sample in mobile phase to a column. Its structure enables uniform diffusion of the sample over the frit surface. 153

12 11 Ferrule type empty column Ferrule type empty columns are standard-type empty columns. A stainless steel tube and an endfitting are tightly connected using a ferrule. Ferrule type empty column length X inner diameter (mm) XC0104WF XC0105WF XC0546WF 50 XC1046WF 100 XC1546WF 150 XC2546WF Ferrule type empty column parts XPEF46F For 4.6 mm inner diameter, Column end assembly, 1-pack XPEF04F For 4.0 mm inner diameter, Column end assembly, 1-pack XPEF05F For 5.0 mm inner diameter, Column end assembly, 1-pack XPSF46F For 4.6 mm inner diameter, Frit, 5-pack XPSF04F For 4.0 mm inner diameter, Frit, 5-pack XPSF05F For 5.0 mm inner diameter, Frit, 5-pack Column end assembly Frit Flange type empty column ( for preparative isolation ) A stainless steel tube with a flange and a cap are tightly connected using a bolt. The inner diameter is 50 mm or more. Flange type empty column 50 mm inner diameter 70 mm inner diameter 150 mm inner diameter length X inner diameter (mm) Max. pressure (MPa) length X inner diameter (mm) Max. pressure (MPa) length X inner diameter (mm) Max. pressure (MPa) XC0551 R 50 XC1071 R 100 XC20B1 R 200 XC1051 R 100 XC2551 R 250 XC3051 R XC2571 R 250 XC3071 R 300 XC5071 R XC30B1 R 300 XC50B1 R 500 XCA0B1 R XC5051 R 500 XCA071 R 1000 XC20B2 R 200 XCA051 R 1000 XC0552 R 50 XC1052 R 100 XC2552 R 250 XC3052 R XC5052 R 500 XCA052 R 1000 Designate a frit pore size depending on particle size. We recommend 2 μm for particle size below 10 μm, 5 μm for particle size above 15 μm. Connection type: Please select your desired connection type. A : 1/16" male nut D : 1/8" female nut E : 1/4" female nut XC1072 R 100 XC2572 R 250 XC3072 R 300 XC5072 R 500 XCA072 R Designate a frit pore size depending on particle size. We recommend 2 μm for particle size below 10 μm, 5 μm for particle size above 15 μm. 100 mm inner diameter XC10A1 R 100 XC30A1 R 300 XC50A1 R 500 XCA0A1 R 1000 XC10A2 R 100 length X inner diameter (mm) Max. pressure (MPa) XC30B2 R 300 XC50B2 R 500 XCA0B2 R mm inner diameter XC20C1 R 200 XC50C1 R 500 XCA0C1 R 1000 XC20C2 R 200 XC50C2 R 500 length X inner diameter (mm) Max. pressure (MPa) XC30A2 R 300 XC50A2 R XCA0C2 R 1000 XCA0A2 R

13 Ferrule type empty column parts Product name Max. pressure (MPa) XPCP052 For inner diameter 50 mm, Cap 7 XPCP053 For inner diameter 50 mm, Cap 14 XPSF0522 For inner diameter 50 mm, 2 μm frit (with distributor) 7 XPSF0532 For inner diameter 50 mm, 2 μm frit (with distributor) 14 XPSF0525 For inner diameter 50 mm, 5 μm frit (with distributor) 7 XPSF0535 For inner diameter 50 mm, 5 μm frit (with distributor) 14 XPRI052 For inner diameter 50 mm, Stainless SS ring 7 XPRI053 For inner diameter 50 mm, Stainless SS ring 14 XPBL052 For inner diameter 50 mm, bolt set (8 pairs) 7 XPBL053 For inner diameter 50 mm, bolt set (12 pairs) 14 XPSU162 For inner diameter 50 mm, 1/16 male nut for connection adaptor 7 XPSU163 For inner diameter 50 mm, 1/16 male nut for connection adaptor 14 XPSU82 For inner diameter 50 mm, 1/8 female nut for connection adaptor 7 XPSU83 For inner diameter 50 mm, 1/8 female nut for connection adaptor 14 *For column parts with an inner diameter of 70 mm or more, please contact us. of flange type empty column Distributor Connection adaptor Frit Stainless SS ring Cap Bolt set Airtight stopper Airtight stoppers are used to prevent column contents from drying. Please use a stopper appropriate for each column connection type. 1/16" airtight stopper XPMSY YMC original type (PEEK), 5-pack XPMSW Waters type (stainless), 5-pack 1/8" airtight stopper XPMS8 Female nut, 2-pack YMC original type W type 1/8" airtight stopper 155

14 11 Pressure resistant empty glass columns Suitable for preparative chromatography Pressure resistant empty glass columns are useful for early purification of natural products, after-treatment of open column chromatography and pre-treatment of preparative HPLC. They are also suitable for removal of impure compounds produced during organic synthesis. The most suitable for self-packing Low-cost preparative isolation can be achieved by self-packing. Pressure resistant empty glass columns are highly flexible tools for preparative isolation because many types of packing materials may be packed into the column. Pressure resistance YMC empty glass columns, made from Pyrex glass, have excellent pressure resistance. They are suitable for spherical and irregular packing materials with a particle size of 50 μm or more. Applicable to medium-pressure and high-performance liquid chromatography systems Pressure resistant empty glass columns can be connected to existing chromatographs, making the preparative isolation easy. Metal free column No metal is used for wetted parts. There is no danger of corrosion caused by acids or of metal contamination in isolation fractions. Pressure resistant empty glass columns are suitable for a metalfree HPLC system. Visibility In contrast to stainless steel columns, the separation behavior of samples analyzed by chromatography can be observed visually. It is useful for preparative isolation or removal of colored material. Pressure resistant empty glass columns (glass tube, column endfitting, tubing fitting kit, airtight stopper) Inner diameter Length 100 mm 300 mm 500 mm 8 mm XC1008FG XC3008FG XC5008FG 20 mm XC1020FG XC3020FG XC5020FG 30 mm XC1030FG XC3030FG XC5030FG 156

15 Parts 1 Glass tube Inner diameter Length 100 mm 300 mm 500 mm 8 mm XT1008FG XT3008FG XT5008FG 20 mm XT1020FG XT3020FG XT5020FG 30 mm XT1030FG XT3030FG XT5030FG 2 Column endfitting (includes frit and packing) 3 Glass frit (with packing) XPEA8 For inner diameter 8 mm, 1-pack XPEA20 For inner diameter 20 mm, 1-pack XPEA30 For inner diameter 30 mm, 1-pack One column requires 2 column endfittings. XPFP83 XPFP2010 XPFP3010 For inner diameter 8 mm, 3 μm pore size For inner diameter 20 mm, 10 μm pore size For inner diameter 30 mm, 10 μm pore size 4 Tubing fitting kit (ferrule, o-ring, male nut) XRFK001 For inner diameter 8, 20, 30 mm (common use) Fitting kit, a set of 2 kits, IN-side and OUT-side, for 1/16 O.D. Teflon tube or stainless tube. 5 Special-purpose Teflon tube XRTT102 1/16 outer diameter, 0.25 mm inner diameter, 10 m XRTT105 1/16 outer diameter, 0.5 mm inner diameter, 10 m For tubing fitting kits Column connection joint (column union and flat seal (2-pack)) 1 Glass tube XRCJ8 For inner diameter 8 mm XRCJ20 For inner diameter 20 mm XRCJ30 For inner diameter 30 mm Used for connection of columns with same diameter in packing. For large columns not described above, please contact us

16

Stability Axial Compression Technology Application Ordering Information

Stability Axial Compression Technology Application Ordering Information 42 YMC-Actus YMC-Actus 43 YMC-Actus Contents Stability... 44 Axial Compression Technology... 45 Application...46-47 Ordering Information...48-49 Introduction Fast semi-preparative chromatography Semi-preparative

More information

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New! Inlet Solvent Filters Filters and Degassers General Use Inlet Solvent Filters Large Surface Areas disposable µm, 0 µm, and 0 µm Pore Sizes Available General Use and Prep Filters for Higher Flow Applications

More information

FITTINGS, LOOPS, AND VALVE ACCESSORIES

FITTINGS, LOOPS, AND VALVE ACCESSORIES FITTINGS, LOOPS, AND VALVE ACCESSORIES Fittings Rheodyne offers a variety of fittings. They differ in material of construction, tubing size, and pressure rating. Materials/Biocompatibility. 316 stainless

More information

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 156 Inlet Solvent

More information

HIGH PRESSURE SWITCHING VALVES

HIGH PRESSURE SWITCHING VALVES HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available

More information

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide Accuracy Starts Here Agilent Captiva Filtration Selection Guide TAbLe of CoNTeNTS Tips & Tools Learn the core concepts surrounding Solid Phase Extraction and best practices for Sample Prep. View the video

More information

IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 Filters & Frits Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

More information

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO 8 SupelPRO Valves Order:.800..00 Technical Service:.800.9.0 Web: www.sigma-aldrich.com/supelco SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled,

More information

14 Chromatography Columns

14 Chromatography Columns 14 Chromatography Columns LC Columns Selection Guide Omnifit Labware columns offer the maximum performance for low to mid pressure liquid chromatography or flow chemistry applications. Simple to assemble,

More information

Instrument Accessories & Parts, Tubing & Connections

Instrument Accessories & Parts, Tubing & Connections Instrument Accessories & Parts, Tubing & Connections ASI Piston Seals for Agilent HPLC Systems Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed

More information

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations. Simplify your search for COLUMN HARDWARE Discover how to maximize results with Isolation Technologies column hardware and accessories that are specifically engineered to meet critical UHPLC, HPLC, and

More information

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bio science ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector

More information

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271 Restek Replacement Parts for Agilent HPLC Systems Meet or exceed OEM performance. Agilent part # qty. cat.# price Preventive Maintenance Kit Includes: rotor seal, needle seat, needle assembly, seat cap

More information

ÄKTA system Training Guide

ÄKTA system Training Guide ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector

More information

FILTERS & COLUMN ACCESSORIES

FILTERS & COLUMN ACCESSORIES 156 FILTERS & COLUMN ACCESSORIES INLET SOLVENT FILTERS PAGE 157 INLINE SOLVENT FILTERS PAGE 160 PRECOLUMN FILTERS PAGE 163 FRITS PAGE 165 GUARD COLUMNS PAGE 170 SEE STARRED PRODUCTS FOR TOP SELLERS! Inlet

More information

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet 1. Description The Agilent Dynamax modular HPLC column system uses a unique technology, Dynamic, to maintain the structure of the packed

More information

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913 GLENCO Syringes As a complement to the Spectra/Chrom chromatographic products, Spectrum manufactures precision syringes for sample injection and collection. These syringes are designed specifically to

More information

Quick Reference Guide. Supplies for Waters HPLC Systems

Quick Reference Guide. Supplies for Waters HPLC Systems Quick Reference Guide Supplies for Waters HPLC Systems works with WATERS SHIMADZU THERMO/DIONEX BRUKER/VARIAN PERKINELMER CTC MORE Put innovation and quality to work on a wide range of GCs and HPLCs in

More information

Glass Columns for Laboratory and Pilot Scale Liquid Chromatography

Glass Columns for Laboratory and Pilot Scale Liquid Chromatography Glass Columns for Laboratory and Pilot Scale Liquid Chromatography 1 Content 1. ECO PLUS Glass Columns...3 1.1 Highlights...3 1.2 Characteristics...3 1.3 Available Versions...4 1.4 Ordering Information...4

More information

S 1125 HPLC Pump System

S 1125 HPLC Pump System Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make

More information

VERITY Purification Systems Build the perfect system to fit your research

VERITY Purification Systems Build the perfect system to fit your research VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC

More information

16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry

16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry 2 Contents Solvent Safety Bottle Caps 4 Bottle Caps Selection Guide Q-Series Solvent Bottle Caps 6 1/4"-28 UNF threaded inlet lines with optional on-off valves T-Series Solvent Bottle Caps 8 Push-through

More information

Solvent Safety Bottle Caps

Solvent Safety Bottle Caps Solvent Safety Bottle Caps 2 Index Page 4 Page 6 Q-SERIES BOTTLE CAPS 1/4-28 UNF ports with optional on-off valves. A screw-in check valve and filter is available for a completely closed solvent supply

More information

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION Waters Advanced Purification (AP) series of glass columns are constructed of biocompatible glass and polymeric materials and can be easily used with

More information

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent Extended ph range from 1-10 provide longer lifetimes with harsh mobile phases Novel bonding reduces residual silanols which cause peak tailing Polymer coated capsule type silica Excellent selectivity for

More information

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Agilent Valve Kit G4231A/B/C and G4232B/C/D Agilent Valve Kit G4231A/B/C and G4232B/C/D Instructions Agilent Valve Kit G4231A/B/C and G4232B/C/D - Instructions This Technical Note describes the installation of the Agilent G4231A/B/C and G4232B/C/D

More information

Liquid Chromatography LC Consumables SSI-LC

Liquid Chromatography LC Consumables SSI-LC Liquid Chromatography LC Consumables SSI-LC-10-2017 Table of Contents HPLC Pumps...3 LC-30AD... 3 LC-20AD / LC-20AB / LC-20ADXR... 4 LC-20AT... 4 LC-20Ai... 5 LC-10ADvp... 5 LC-10ATvp... 6 LC-10Ai... 6

More information

Installing the 6850 Direct Valve Column Connector Kit

Installing the 6850 Direct Valve Column Connector Kit Use this kit to bypass the inlet and connect your 6850 gas or liquid sampling valve directly to a column. To use this kit, your 6850 GC must have a purged packed inlet. This kit contains: Installing the

More information

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent Valve Kit G4231A/B and G4232A/B/C Agilent Valve Kit G4231A/B and G4232A/B/C Instructions Contents Typical Applications 2 Dual column selection (G4231A/B or G4232A/B/C) 2 Sample enrichment and sample cleanup (G4231A/B or G4232A/B/C) 2 Alternating

More information

HPLC Tubing and Fittings Hints & Tips for the Chromatographer

HPLC Tubing and Fittings Hints & Tips for the Chromatographer HPLC Tubing and Fittings Hints & Tips for the Chromatographer By William S. Letter (Chiralizer Services, L.L.C.) INTRODUCTION: Setting up a high pressure liquid chromatography (HPLC) system to run trouble-free

More information

98 동방하이테크상사 T.(02) F.(02)

98 동방하이테크상사   T.(02) F.(02) 98 동방하이테크상사 http://www.allpump.co.kr T.(0)57-69 F.(0)57-69 00--7 troduction to Upchurch Scientific Valves Valves troduction Valves jection and Selection Valves for Pressures to,000 psi (69 bar) Switching

More information

Tubing Cutter for 1/16" Stainless Steel Tubing

Tubing Cutter for 1/16 Stainless Steel Tubing Delivery Tubing and ccessories 311 P000257 Tubing Cutter for 1/16" Stainless Steel Tubing 58692-U Low-cost tool cuts 1/16" stainless steel tubing without obstructing the bore. Easily cut 1/16" OD stainless

More information

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like

More information

Upchurch High Pressure Fittings & Connectors

Upchurch High Pressure Fittings & Connectors .010 thru-hole P-742 PEEK ZDV Union. 9 2.050 thru-hole P-760 PEEK ZDV Union P-704 PEEK ZDV Union. 9 2. 9 2 Fingertight Fittings ONE-PIECE FINGERTIGHT FITTINGS INTRODUCTION For Coned Ports For convenience

More information

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D Instructions Agilent Valve Kit G4231A/C and G4232C/D - Instructions This technical note describes the installation and application of the Agilent

More information

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C C OMPONENT S F O R A C L O S E D - S YS T E M HPL C TM Western Analytical Products, Inc hplc and gc columns and accessories fittings, tubing, valves, frits and filters lab and industrial safety products

More information

Polymeric Fittings Low Pressure

Polymeric Fittings Low Pressure INDEX PPS Nuts for Flat Bottom Fitting Details 59 PEEK Flangeless Nuts 62 Polyacetal Color Coded Flangeless Nuts 63 Polypropylene Flanged Fingertight Nuts 64 Unions 65 Bulkhead Unions 67 PEEK Tees, Crosses

More information

MODEL 905V OPERATING INSTRUCTIONS

MODEL 905V OPERATING INSTRUCTIONS MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions

More information

Ultra High Performance Fittings. Fittings Connectors Kits

Ultra High Performance Fittings. Fittings Connectors Kits Ultra High Performance Fittings Fittings Connectors Kits Ultra High Performance Fittings Introduction Ultra Performance Fittings Introduction high Temperature Versions Withstand Temperatures up to 200ºC

More information

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N ) CRD 200 Product Manual Page 1 of 18 PRODUCT MANUAL FOR CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N 062983) CRD 200 (2 mm) (P/N 062986) Dionex Corporation, 2006 Document No. 065068 Revision 04 November

More information

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares Competitive Comparison Maximize Performance and Minimize Maintenance with LC Spares high-quality spare parts and preventative maintenance kits Regular replacement of crucial parts can help keep your HPLC

More information

Spring Column Hardware

Spring Column Hardware Spring Column Hardware For Use with Multipacker Packing Instruments High-efficiency axial compression packing mechanism Extend media lifetime Mobile Dynamic Axial Compression (DAC) column Easily packed

More information

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS MS Identification of Trace level Impurities from a Non-MS Compatible Mobile Phase Using ACQUITY UPLC System with 2D Technology by Heart-cutting and Online Sample Concentration Bronsky Gopinadh, Dilshad

More information

InertSustainSwift. Achieving separations faster than ever before

InertSustainSwift. Achieving separations faster than ever before InertSustainSwift TM C8 Achieving separations faster than ever before InertSustainSwift C8 HPLC Columns Increasing Efficiency, Throughput and Productivity InertSustainSwift C8 columns are designed to deliver

More information

NEW HPLC - SYSTEM LINE

NEW HPLC - SYSTEM LINE NEW HPLC - SYSTEM LINE S c h a m b e c k S F D G m b H Drieschweg 13A D-53604 Bad Honnef/Germany Phone: +49 2224 9239-0 E-Mail: info@schambeck-sfd.com Internet: www.schambeck-sfd.com S 9425 HPLC solvent

More information

GE Healthcare. Valve INV-917. Instructions

GE Healthcare. Valve INV-917. Instructions GE Healthcare Valve INV-917 Instructions INV-917 2 1 3 7 4 5 6 Important user information All users must read this entire manual to fully understand the safe use of Valve INV-917. Important! Valve INV-917

More information

5 µm Preparative HPLC Columns

5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns Your only as good as your last product. ~ James Browne, Continuous Improvement Program Manager/Lean/6-Sigma Program Manager, Wexford, Ireland

More information

Flow System Accessories

Flow System Accessories Flow System Accessories Fitting Systems MicruX is able to provide different accessories, from several suppliers, usually required for using the standard thinfilm (micro)electrodes in flowing liquids systems.»

More information

VACUUM FILTRATION

VACUUM FILTRATION VACUUM FILTRATION Introduction Glass Microfiltration: Support Systems mm Glass Microanalysis Holders mm Glass Microanalysis Holders 7 mm Glass Microanalysis Holders 7 mm Glass: All-Teflon seal 7 mm Glass:

More information

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Deburring an Upchurch Scientific fitting in Oak Harbor, WA. The Very High Pressure (VHP) reusable fitting, VHP-320, is one of the exciting new products in the

More information

Determination of Sudan Dyes I IV in Curry Paste

Determination of Sudan Dyes I IV in Curry Paste Determination of Sudan Dyes I IV in Curry Paste Suparerk Tukkeeree and Jeffrey Rohrer 2 Thermo Fisher Scientific, Bangkok, Thailand; 2 Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 23 Key

More information

Jour. Chromatography Fluid/Gas Transfer. Jour. CATALOG 20 INT. VICI Jour Chromatography Fluid/Gas Transfer

Jour. Chromatography Fluid/Gas Transfer. Jour.   CATALOG 20 INT. VICI Jour Chromatography Fluid/Gas Transfer www.vici-jour.com VICI Jour Chromatography Fluid/Gas Transfer Jour Chromatography Fluid/Gas Transfer Jour VICI AG International Parkstrasse 2 6214 Schenkon Switzerland Phone +41 41 925 62 00 Fax +41 41

More information

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems HPLC Essentials Genuine Replacement Parts for HPLC Systems 20 YEARS Turning Visions into Reality 800-356-1688 814-353-1300 2 Becky Wittrig HPLC Products Marketing Manager 4+ years of service! did you know?

More information

This convenient system is made entirely of inert parts: glass, Baseline drift

This convenient system is made entirely of inert parts: glass, Baseline drift 95 P000515 55020 9960342 Supelco Mobile Phase Degassing System 55060-U Eliminates: Flow instabilities Mobile Phase Reservoir System Detector noise This convenient system is made entirely of inert parts:

More information

tubing, faucets and fittings

tubing, faucets and fittings small Bore teflon ptfe tubing Order by the Foot* Superior Chemical Resistance High degree of flexibility allows multiple twists and turns in tight spaces Non-stick surface will not collect particulates

More information

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter HPLC ACCESSORIES IDEX Injection Valves IDEX Injection Valves Manual IDEX MANUAL INJECTION VALVES DESCRIPTION POS. SENSING SWITCH MAX PSI FITTING HIGH PRESSURE, ANALYTICAL (accepts a 22 gauge needle) FITS

More information

Prep Flash TLC. Preparative Chromatography

Prep Flash TLC. Preparative Chromatography Prep Flash TLC Preparative Chromatography........ 148 183 Introduction...................... 148 151 Columns....................... 152 171 GraceAlpha Columns 152 155 Vydac MS Columns 156 157 Vydac TP

More information

*Order ferrules separately. Outlet Splitter. Outlet Splitter 14898

*Order ferrules separately. Outlet Splitter. Outlet Splitter 14898 Capillary Connectors Universal Capillary Connectors One size fits tubing from 0.25mm i.d. to 0.53mm i.d. Available in straight or Y configurations Capillary connectors form a gas-tight seal when heated

More information

260 Solvent Vapor Exit Accessory

260 Solvent Vapor Exit Accessory Theory of operation The Solvent Vapor Exit (SVE) is a GC accessory for performing large volume injections with a Cool On-Column inlet (COC). At the start of the run, the SVE solenoid valve is open as the

More information

Connectors & Connectors with valves

Connectors & Connectors with valves Connectors & Connectors with valves Inside... Omnifit Cap instructions... Small Bore Connectors... 3 with valves... Large Bore Connectors... 5 with valves... 5 T Block Connector... 6 In-line Connectors...

More information

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 ) Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Giorgis Isaac, 2 and Larry T. Taylor 1 1 Department

More information

Agilent G5632 Valve Kit Instructions

Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Contents Typical Applications 2 Alternating Column Regeneration (2 position/10 port valves only) 2 Dual column selection 3 Sample

More information

ReciPro Liquid Metering Pumps. Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options

ReciPro Liquid Metering Pumps. Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options ReciPro Liquid Metering Pumps Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options ReciPro HP Series Eldex metering pumps can be used wherever precise flow rate

More information

Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors

Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors Instructions for Use SeQuant CARS Continuous Auto-Regeneration System CONTENTS General Information...

More information

Agilent 1200 Series Valves

Agilent 1200 Series Valves Agilent 1200 Series Valves User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 .

(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 . Low Pressure FITTINGS & CONNECTORS Dimensions for /4-8 Upchurch Scientific eliminate the need to flange. This removable and reusable system provides several benefits: (pages 58 and 59) Convenience: Our

More information

SPE Manifolds and Accessories

SPE Manifolds and Accessories SPE Manifolds and Accessories A comprehensive range of accessories to improve your sample preparation workflow HyperSep Positive Pressure Manifold HyperSep Positive Pressure Manifold Positive Pressure

More information

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN 80-6000-32 Physiological Calibration Standard II 80-2037-62 Calibration standard physiological fluid 80-2037-61 CALIBRATION STANDARD PROTEIN HYDROLYSATE 80-2104-53 1/8" FLANGELESS FITTING (PK 5) 80-2108-41

More information

QuickSplit TM Flow Splitters

QuickSplit TM Flow Splitters Quick TM Flow ters Quick TM Flow ter Features: Fluid resistor technology eliminates tedious adjustments to capillary tubing for split ratio optimization ratios are stable and reproducible, and not affected

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

2017 HPLC Product Catalog 1

2017 HPLC Product Catalog 1 1 2017 HPLC Product Catalog ORDERING INSTRUCTIONS BY PHONE Call toll-free 800.682.6480 or 952.895.8292. Our normal business hours are 8 a.m. to 5 p.m. (Central Standard Time). BY FAX Dial 952.895.8493

More information

Miniature Multimedia Valves

Miniature Multimedia Valves 2 Inert Isolation PTFE 3-Way Solenoid Valve Series 1 The Series 1 diaphragm type valve has a low internal volume and rapid response time, which enables users to get readings quickly for their analysis.

More information

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis Joan M Stevens, Ph.D., Mark Crawford and Greg Robinson Single Presenter Name Abstract:

More information

Dionex CRD Carbonate Removal Device

Dionex CRD Carbonate Removal Device Thermo Scientific Dionex CRD Carbonate Removal Device Product Manual P/N: June 2013 Part of Thermo Fisher Scientific Product Manual for Dionex CRD Carbonate Removal Device 180 CRD 180, 0.4 mm (P/N 079960)

More information

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test GlycoChrom TM HPLC Analyzer Hardware Installation and System Test PIN 410-5004 For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-8 00-424-6723) ,, Table of Contents

More information

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters ADAPTERS Whether converting joint types, reducing or enlarging joints, or creating connections in a distillation apparatus, Kimble offers a comprehensive selection of adapters including bushing adapters,

More information

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Extended range HPLC has been investigated for many years; however, progress was delayed because of

More information

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa Septa Chromatogram Cross Reference Guide Actual Size Drawing Measurement 1/4" (6mm) Shimadzu*, SRI* Chromatographs 3/8" (9.5mm) 7/16" (11mm) Antek, Finnigan 9100, 9600, Gow- Mac, Agilent 5700, 5880 & 5900,

More information

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment chromatography Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment Product Specifications Thermo Scientific Dionex UltiMate 3000 products are UHPLC compatible by design, establishing

More information

HPLC System S 600 Series

HPLC System S 600 Series HPLC System S 600 Series The Sykam HPLC System S 600 Series is intended for the ambitious analyst. The system configuration is highly variable and several upgrade options make this system suitable for

More information

cheminert fittings Low Pressure Flangeless Tube End Fittings Flangeless tube end fittings 1/4-28

cheminert fittings Low Pressure Flangeless Tube End Fittings Flangeless tube end fittings 1/4-28 Low Pressure Flangeless Tube End Fittings Cheminert low pressure fittings are ideally suited for flow injection analysis, low pressure liquid chromatography, and stream sampling devices. They may be safely

More information

1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION

1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION 1Valcor Scientific Subminiature Teflon Valve 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS Model SV20-1 is suitable for a broad range of light industrial applications, both new and retrofit.

More information

850 Professional IC. AnCat MCS Manual EN

850 Professional IC. AnCat MCS Manual EN 850 Professional IC AnCat MCS 2.850.3030 Manual 8.850.8052EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com 850 Professional IC AnCat

More information

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals Phenomenex Exclusive! Easy Seals Inlet Base Seals Guaranteed fit for Agilent 5000, 6000 and 7000 Series GCs The Easy Seals Gold Standard No Strained Hands No Troublesome Washers or Adaptors Continuing

More information

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Agilent Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Your chromatography analysis does

More information

vision safety caps Manufacturer: VisionEC-Lab Ltd. Hungary

vision safety caps Manufacturer: VisionEC-Lab Ltd. Hungary vision safety caps Manufacturer: VisionEC-Lab Ltd. Hungary Safety Caps for Eluent Bottles luer female connector 0,22µm integrated PTFE membrane CNC fittings PTFE body PTFE o-ring high resistant PBT cap

More information

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers HyperShear TM HPLC and UHPLC s Reduce baseline noise, increase sensitivity and improve gradient accuracy Decrease mixing and delay volume without sacrificing mixing efficiency Increase reaction efficiency

More information

G1160A Agilent 1100 Series Multiple Purpose Switching Valve

G1160A Agilent 1100 Series Multiple Purpose Switching Valve G1160A Agilent 1100 Series Multiple Purpose Switching Valve Description: The G1160A Agilent 1100 Series Multiple Purpose Switching Valve is a stainless steel 12-position, 13-port motorized valve operated

More information

Hot Injection Adapter Kit - Installation Guide

Hot Injection Adapter Kit - Installation Guide Hot Injection Adapter Kit - Installation Guide This guide provides the instruction for installing the Hot Injection Adapter kit (P/N 19050733) on the SSL/SSLBKF injector for the use with an external device

More information

1110 Valves. Introduction

1110 Valves. Introduction Introduction Specific part numbers are not given in this portion of the service manual. For all replacement part numbers, refer to the IPB portion of this document. This document does not provide instruction

More information

881 Compact IC pro. 881 Compact IC pro Anion MCS. Manual EN

881 Compact IC pro. 881 Compact IC pro Anion MCS. Manual EN 881 Compact IC pro 881 Compact IC pro Anion MCS Manual 8.881.8014EN Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com 881 Compact IC pro

More information

Agilent 1200 Series Manual Injector

Agilent 1200 Series Manual Injector Agilent 1200 Series Manual Injector User Manual 1200 Series MI User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006, 2008 No part of this manual may be reproduced in any form or by

More information

Application Note. Authors. Abstract. Energy & Chemicals

Application Note. Authors. Abstract. Energy & Chemicals Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors

More information

Motor Valve MV-7/IMV-7

Motor Valve MV-7/IMV-7 Motor Valve MV-7/IMV-7 INSTRUCTIONS 1. Introduction Motor Valves MV-7/IMV-7 are a 3-position, 7-port motorized valves designed to he used as automatic sample injection valves or system valves. The valves

More information

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL 1993 Dionex Corporation Document No. 034859 Revision 02 September 1993 1993 Dionex Corporation All rights reserved worldwide Printed in the United States

More information

HPLC SYSTEM S 500 SERIES

HPLC SYSTEM S 500 SERIES HPLC SYSTEM S 500 SERIES The Sykam HPLC System S 500 Series is intended for all routine analysis as well as for the ambitious analyst. The system configuration is highly variable and several upgrade options

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories Copyright 2004 Alltech Associates, Inc.UNP brochure #487K accessories GC Organizers 5-Column Storage Unit Plastic Storage Box 10-Column Storage Unit Utility Cabinet Lab Storage Bin Unit GC Organizers

More information