Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!
|
|
- Beatrice Berry
- 5 years ago
- Views:
Transcription
1 Inlet Solvent Filters Filters and Degassers General Use Inlet Solvent Filters Large Surface Areas disposable µm, 0 µm, and 0 µm Pore Sizes Available General Use and Prep Filters for Higher Flow Applications It is good practice to filter your solvents to prevent pump damage. Upchurch Scientific 6 stainless steel filters provide that protection. Their large surface areas mean longer life without pump cavitation. Because filters should be changed periodically, we make it easy to replace them without tools. For those filters using a plastic nut, thread the nut into the filter and finger tighten. Our other filters have stems, allowing easy insertion directly into your inlet tubing. The filters with stems are 00% 6 stainless steel. Filters with threaded fittings have threaded Kel-F (PCTFE) caps. Please Note: The internal design of the A-09 and the A-0A Filters allows solvent to be drawn to within approximately /8 of the bottom of your solvent bottle. Maximum Suggested Flow Rates: Flow rates are determined by porosity and surface area. Filter Porosity Max. Flow Rate A-4 µm 0 ml/min A-40 0 µm 40 ml/min A-0 0 µm 40 ml/min A-0A 0 µm 40 ml/min A-09 0 µm 40 ml/min A-0 0 µm 40 ml/min A-8 µm 80 ml/min A-5 0 µm 00 ml/min A-5A 0 µm 00 ml/min A-6A 0 µm 00 ml/min A-7A 0 µm 00 ml/min A-0A 0 µm 00 ml/min A-A 0 µm 00 ml/min A- 0 µm 00 ml/min A-A 0 µm 00 ml/min New! A-4 µm with P-00 Fingertight Nut for /8 OD tubing.7 A-0 0 µm for /6 ID tubing. We recommend using µm filters to disperse sparging gas. For inlet solvent filtering, we recommend 0 µm or 0 µm filters to allow sufficient flow to prevent pump cavitation. Change filters every six months to one year, depending on your mobile phase. A-0A 0 µm with P-5/P-00 Flangeless Fittings for /8 OD tubing A-5A 0 µm with P-5/P-00N Flangeless Fittings for /8 OD tubing A-0 0 µm for /8 ID tubing A-0A 0 µm with U-655/U-650 Flangeless Fittings for /4 OD tubing New! General Use Inlet Solvent Filters For Analytical HPLC A-40 0 µm Inlet Solvent Filter, for /8 OD tubing $.50 A-4 A-40, 5-pack, for /8 OD tubing 8.00 A-4 µm Inlet Solvent Filter, for /8 OD tubing.0 A-4 A-4, 5-pack, for /8 OD tubing.00 A-8 µm Inlet Solvent Filter with stem, for /8 ID tubing 5.09 A-0 0 µm Inlet Solvent Filter with stem, for /6 ID tubing 6.9 A-0A 0 µm Inlet Solvent Filter with Flangeless Fittings, for /8 OD tubing.4 A-09 0 µm Inlet Solvent Filter with stem, for /6 ID tubing.6 For Waters Analytical HPLC Systems A-A 0 µm Inlet Solvent Filter, for /6 OD tubing $ 9.77 A-0 0 µm Inlet Solvent Filter with stem, for /8 ID tubing.4 For Preparative HPLC Systems A-5 0 µm Inlet Solvent Filter with stem, for /6 ID tubing $ 0. A-5A 0 µm Inlet Solvent Filter with Flangeless Fittings, for /8 OD tubing A-6A 0 µm Inlet Solvent Filter, for 5/6 OD tubing A-7A 0 µm Inlet Solvent Filter, for /4 OD tubing A-0A 0 µm Inlet Solvent Filter, for /4 OD tubing A- 0 µm Inlet Solvent Filter with stem, for /6 ID tubing 5.49 A-A 0 µm Inlet Solvent Filter with Flangeless Fittings, for /8 OD tubing Inlet Solvent Filter Kits A-00 Inlet Solvent Filter Kit 0 µm $ Contains: One length of FEP Tubing, () P-00 Fingertight Fitting, (5) Disposable A-0 0 µm Filters A-0 Inlet Solvent Filter Kit µm Contains: One length of FEP Tubing, () P-00 Fingertight Fitting, (5) Disposable A- µm Filters A-0 P-00 Fingertight Fitting with FEP Tubing 4.6 /8 OD x /6 ID x Includes a P-00 PCTFE One-Piece Fitting. Includes a P-5 Tefzel (ETFE) Nut and a P-00 ETFE Ferrule. Includes a P- PEEK Nut and a P- ETFE Ferrule. 4 Includes a P-5 ETFE Nut and a P-00N ETFE Ferrule. 5 Includes a U-6 PEEK Nut and a U-660 ETFE Ferrule. 6 ORDER Includes a U-655 PEEK Nut and a U-650 ETFE Ferrule. 5
2 Filters and Degassers Inlet Solvent Filters Stainless Steel Bottom-of-the-Bottle Solvent Filters draws Solvent from within /8 of the Bottom of the Bottle Replaceable Stainless Steel Filter Cups For /8 and /6 OD Tubing Upchurch Scientific patented Bottom-of-the-Bottle Solvent Filter Assemblies feature a µm or 0 µm replaceable stainless steel filter cup and a design that allows solvent to be drawn from within /8 of the bottom of your solvent bottle. The filter cups are inexpensive and easy to replace, making this an economical, trouble-free choice. To replace the filter cup, loosen the PEEK lock nut and pull the filter cup off; replace it with a new cup, and retighten the lock nut. Please Note: The filter cups are interchangeable. Thus, you can make a 0 µm filter into a µm filter (or visa versa) by simply switching the replacement cups. The wetted components of these filters are PEEK, Tefzel (ETFE) and 6 stainless steel. Bottom of the Bottle Solvent Filter Assembly: PEEK Fitting ETFE Ferrule PEEK Lock Nut ETFE Seal.7 PEEK Solvent Inlet Tube Bottom-of-the-Bottle Inlet Solvent Filter Maximum Flow Rates: µm up to 0 ml/min. 0 µm up to 40 ml/min. Upchurch Scientific Bottom-of-the-Bottle Filters are protected by one or more U.S. patents. 6 Stainless Steel Replaceable Filter Cup 6 Why Use An Inlet Solvent Filter? To filter out particulate matter from the solvent that may otherwise damage expensive hardware. To disperse sparging gas into very fine bubbles for minimal solvent disturbance and maximum sparging efficiency. To prevent particulates originating in the sparging system from entering your mobile phase reservoir. To hold your tubing in place at the bottom of the bottle. ORDER Bottom-of-the-Bottle Solvent Filters A µm Filter Assembly, for /8 OD tubing with A-50 filter cup $ 59. A-55 µm Filter Assembly, for /8 OD tubing with A-5 filter cup 59. A-55 0 µm Filter Assembly, for /6 OD tubing with A-50 filter cup 59. A-55 µm Filter Assembly, for /6 OD tubing with A-5 filter cup 59. A-50x 0 µm Stainless Steel Replacement Solvent Filter Cups, 0-pk 5.85 A-5x µm Stainless Steel Replacement Solvent Filter Cups, 0-pk 5.85 Includes a P-00 ETFE and a P-0 Nut Includes a P- ETFE Ferrule and a P- PEEK Nut Typically for Waters systems TOP SELLER see starred products in price block.
3 Inlet Solvent Filters Filters and Degassers UHMWPE Bottom-of-the-Bottle Solvent Filters Replaceable Filter Cup economical The design of these Upchurch Scientific solvent filters allows your tubing to pass through to the bottom of the filter cup. This feature enables the filter to draw solvent from within.0 (.5 mm) of the bottom of your solvent bottle. Each of the two biocompatible solvent filter assemblies comes with a disposable 0 µm ultra-high molecular weight polyethylene (UHMWPE) filter cup. These filter cups thread directly into the inert Tefzel (ETFE) body, creating a good seal that ensures all mobile phase is properly filtered. Choose from versions designed for use with /6 and /8 OD tubing. Please Note: UHMWPE is a hydrophobic material. To establish proper surface wetting, you may need to prime the filter with methanol or acetonitrile..55 PEEK Bottom-of-the-Bottle Solvent Filters our Most Recommended Filtering Unit! 00% PEEK Polymer Construction easy Operation No Fittings Required! These Upchurch Scientific biocompatible filters are made from 00% PEEK polymer. Each has two PEEK frits. The bottom frit ( µm or 0 µm) will draw solvents from within.08 ( mm) of the bottom of the solvent bottle. The µm frit on the side may be used for a /8 OD helium sparging line. To use, simply press fit your appropriately sized fluoropolymer tubing firmly into the top holes. That s it! Port for solvent intake line Port for your sparging line (optional use) Filters solvent from the bottom of your solvent bottle Filters and disperses incoming sparging gas (optional use).5 A-446 Solvent Filter Maximum flow up to 5 ml/min A-45 Bottom-of the-bottle Filter A-48 Bottom-of the-bottle Filter (for small neck bottles) Maximum Flow Rate up to 0 ml/min. We recommend you use our FEP or PFA fluoropolymer with our PEEK Bottom-of-the-Bottle Solvent Filters. Our fluoropolymer tubing is extruded to some of the tightest tolerances in the industry. Tubing from other manufacturers may have OD variances that can cause the tubing to slip out of the filter tubing ports. Please refer to pages 7 and 74 for our complete line of fluoropolymer tubing. UHMWPE Bottom-of-the-Bottle Solvent Filters A µm UHMWPE Filter Assembly for /6 OD tubing $ 7.64 A µm UHMWPE Filter Assembly for /8 OD tubing 7.64 A-47 0 µm UHMWPE Replacement Solvent Filter Cups, 5-pk.05 PEEK Bottom-of-the-Bottle Solvent Filters A-45 µm PEEK Filter for /8 OD tubing $.0 A-46 µm PEEK Filter for /6 OD tubing.0 A-47 µm PEEK Filter for /8 OD tubing, for small-neck (GL-8) bottles.0 A-48 0 µm PEEK Filter for /8 OD tubing, for small-neck (GL-8) bottles.0 A µm PEEK Filter for /8 OD tubing.0 A-44 0 µm PEEK Filter for /6 OD tubing.0 A-450 µm PEEK Filter for /6 OD tubing.50 A-45 0 µm PEEK Filter for /6 OD tubing.50 A-45 µm PEEK Filter for /6 OD tubing, for small-neck (GL-8) bottles.50 A-45 0 µm PEEK Filter for /6 OD tubing, for small-neck (GL-8) bottles.50 Includes a P-00 ETFE Ferrule and a P-45 PFA Nut Includes a P-00 ETFE Ferrule and a P-45 PFA Nut ORDER Typically for Waters 7 systems
4 Filters and Degassers Bottle Caps and Plugs Bottle Caps inexpensive extremely Simple No Threaded Ports or Fittings! If you are looking for a bottle cap that is quick and easy to use, but still allows many connection options, we have just what you need! Upchurch Scientific injection-molded caps are manufactured of inert Tefzel ETFE and polypropylene. They fit standard GL-45 or smaller-neck GL-8 glass bottles. Each cap has three holes. With two of the holes you simply push your tubing straight through. The third hole, with a luer taper, can be used for a number of options. Any male luer will fit snugly in this hole, or you can use our A-66 or A-67 Plug. Exceptions are the A-60 and A-60B Bottle Caps. Please see the note below right. To ensure a tight seal, use Upchurch Scientific fluoropolymer tubing with these bottle caps (pages 7 and 74). Holes for /8 OD tubing Additional hole for luer Holes for /8 OD tubing Additional hole for luer A self-regulating sparging system can help reduce helium consumption and improve pump performance. Set this up by pressing your tubing through the appropriate holes in your bottle cap and attaching each line to a filter. Sparge your mobile phase with an inert gas (preferably helium) for 5 0 minutes. Then reduce the flow of the sparging gas to a maximum of 5 psi (0.4 bar) and insert a plug (A-66 or A-68) into the remaining port of the cap. The sparging gas will shut off once the incoming pressure equals the pressure inside the reservoir. As the mobile phase is consumed and the internal pressure lowers, sparging gas will enter to keep the system pressurized and degassed. Please Note: If gas leaks while pressurizing the bottle, try removing the sealing ring from the bottle, as it sometimes interferes with the sealing of Upchurch Scientific bottle caps. one concern with sparging systems is the possibility of solvent backing up the sparging inlet line. This can occur if the gas tank completely evacuates with the regulating valves open, creating a vacuum in the tubing. Solvent backup may damage sparging system components and cause cross-contamination of mobile phase reservoirs. To help prevent solvent backup, install our CV-00 Inline Check Valve (page ) along the tubing line that runs between the gas supply and the solvent bottle. For a more efficient degassing system, please see the Systec HPLC Vacuum Degassing Systems on pages 8 9. Please see our Quick-Stop Luer Check Valve on page for another solvent inlet. A-60 GL-45 Bottle Cap for /8 tubing A-6 GL-8 Bottle Cap for /8 tubing Note 0 Bottle Cap Plugs and Adapters Use our A-66 Bottle Cap Plug to seal the third tapered luer hole found in most Upchurch Scientific bottle caps. Or, use our A-68 Plug to seal any unused /6 or /8 bottle cap holes. Alternatively, try our A-67 or A-69 Filter Bottle Cap Plug to cap an unused hole in your cap. The 0 µm stainless steel frit in these products prevents foreign matter from contaminating your solvent while leaving the bottle open to the atmosphere, thus allowing fluid to be pulled out without creating a vacuum (generally not used with sparging applications). All plug bodies are manufactured from ultrahigh molecular weight polyethylene (UHMWPE). Our P-600 Bottle Cap Adapter is designed to allow use of / OD tubing with our caps. Just insert the Adapter into a tubing cap hole, then connect your / OD tubing with our F-6S or F-6H MicroTight Fitting (page 9). A-66 Bottle Cap Plug A-69 Filter Bottle Cap Plug 0 µm stainless steel frit P-600 Bottle Cap Adapter to connect / OD tubing ORDER The A-60 and A-60B Bottle Caps have a slightly different configuration than the other caps. One hole accepts /6 OD tubing, designed for use with a Waters system. The remaining two holes accept /8 OD tubing. Unlike the other caps, the A-60 does not have a tapered luer hole. If desired, use our A-68 Plug or A-69 Filter Plug for one of the /8 holes. Bottle Caps for GL-45, L Bottles A-60 for /6 OD tubing, Red $.69 A-60B for /6 OD tubing, Blue.69 A-60 for /8 OD tubing, Red.69 A-60B for /8 OD tubing, Blue.69 A-60 for /6 OD tubing, Red.69 A-60B for /6 OD tubing, Blue.69 Bottle Caps for GL-8, 4 L Bottles A-6 for /8 OD tubing, Black $.69 A-6 for /6 OD tubing, Black.69 Bottle Cap Plugs and adapter A-66 Bottle Cap Plug for luer hole, UHMWPE $ 4.5 A-67 Filter Bottle Cap Plug for luer hole, UHMWPE 6. with 0 µm stainless steel frit A-68 Bottle Cap Plug for /6, /8 or /6 hole, UHMWPE 4.5 A-69 Filter Bottle Cap Plug for /6, /8 or /6 hole, UHMWPE 6. with 0 µm stainless steel frit P-600 Bottle Cap Adapter for /8 hole, PEEK.4 to connect / OD tubing Designed for use with our F-6S or F-6H Fitting (page 9) and / OD tubing (pages 69, 70, 7 and 77).
5 Frit-In-A-Ferrule and Sample Filters Filters and Degassers Frit-In-A-Ferrule seals and Filters Simultaneously Less Expensive and More Convenient than Traditional Inline Filter Systems P-7 Available in Both Flangeless and Super Flangeless Versions Now you can filter at any point in your system where /6 or /8 OD tubing is used in a flat-bottom /4-8, M6 or 5/6-4 connection. The Upchurch Scientific Frit-In-A-Ferrule product line is designed to seal and filter simultaneously by incorporating a frit into the body of a flat-bottom ferrule. This simple design allows you to eliminate traditional inline filters and reduce the number of additional connections in your system. The Frit-In-A-Ferrule comes in two general designs standard Flangeless and Super Flangeless. The ferrule body of the Flangeless unit is manufactured from Kel-F (PCTFE) polymer and incorporates a stainless steel (SST) frit. The ferrule body of the Super Flangeless unit is made from PEEK polymer, and the lock ring is stainless steel. The frits in the Super Flangeless versions are available in PEEK and stainless steel. Both the Flangeless and Super Flangeless versions offer the choice of 0.5 µm or µm frits. P-70 P-75 P-7 Frit in a Ferrule Specifications: Part Number Ferrule System Frit Dimensions (dia. x thickness) Theoretical Swept Volume Maximum Pressure (psi/bar) P-70/P-7 Super Flangeless.06 x.06.74/.6 µl 5,000 (45) P-7/P-7 Flangeless.06 x.06.74/.6 µl,000 (07) P-74/P-75 Super Flangeless.046 x.00.0/.6 µl 5,000 (45) P-70/P-7 Super Flangeless.094 x.06.69/.4 µl,400 (96) P-7/P-7 Flangeless.094 x.06.69/.4 µl 400 (8) P-74/P-75 Super Flangeless.094 x.04.5/.96 µl 4,000 (76) Results obtained using a Delrin nut on /6 OD PEEK tubing, with water as the solvent. Results obtained using a Delrin nut on /8 OD Tefzel tubing, with water as the solvent. Results obtained using a PEEK nut on /8 OD PEEK tubing, with water as the solvent. Note Nuts that can be used with the Frit-In-A-Ferrule line: Super Flangeless, Pages 4 Flangeless, Pages Disposable Sample Filters excellent System Protection Ultra-Low Hold-Up Volume 0.5 µm and µm Porosity These Disposable Sample Filters are designed to remove particles from analytical HPLC samples. The polypropylene holder incorporates a / thick, /8 diameter stainless steel frit, which causes very little back pressure. To use, just attach one of these filters onto the end of any standard luer syringe, such as our B-0 found on page 49. B-00 and B-0 Disposable Sample Filters TOP SELLER see starred products in price block. Frit-In-A-Ferrule For /6" OD Tubing Frit Ferrule Qty. P-70x µm SST Super Flangeless, Natural PEEK, SST lock ring 0-pk $ P-7x 0.5 µm SST Super Flangeless, Black PEEK, SST lock ring 0-pk P-7x µm SST Flangeless, Green PCTFE 0-pk 6.7 P-7x 0.5 µm SST Flangeless, Blue PCTFE 0-pk 6.7 P-74x µm PEEK Super Flangeless, Natural PEEK, SST lock ring 0-pk 90.6 P-75x 0.5 µm PEEK Super Flangeless, Black PEEK, SST lock ring 0-pk 90.6 Frit-In-A-Ferrule For /8" OD Tubing Frit Ferrule Qty. P-70x µm SST Super Flangeless*, Natural PEEK, SST lock ring 0-pk $ P-7x 0.5 µm SST Super Flangeless*, Black PEEK, SST lock ring 0-pk P-7x µm SST Flangeless, Green PCTFE 0-pk 6.7 P-7x 0.5 µm SST Flangeless, Blue PCTFE 0-pk 6.7 P-74x µm PEEK Super Flangeless*, Natural PEEK, SST lock ring 0-pk 90.6 P-75x 0.5 µm PEEK Super Flangeless*, Black PEEK, SST lock ring 0-pk 90.6 Disposable HPLC Sample Filters B-00 µm Disposable Filters 00-pk $ 65.7 B µm Disposable Filters 00-pk 65.7 ORDER *The /8 Super Flangeless versions cannot be used in M6 ports.
6 Filters and Degassers Precolumn and Inline Filters Ultra-Low Volume Precolumn Filter Low Swept Volume Precolumn Filter for /6 OD Tubing With a.00 diameter thru-hole, our A-8 Filter has one of the lowest swept volumes (0.6 µl*) of any HPLC precolumn filter available, ensuring maximum protection with very little band broadening. Pressure rated to 9,000 psi (60 bar)..48 A µm SST frit Inline Solvent Filters excellent for General Purpose Inline Use µm and 0 µm Porosity Frits Available Placed between the pump and sample injection valve, our Inline Solvent Filters trap particles released through normal piston seal wear. Without an inline filter, these particles can be flushed through your system s tubing to the sample injection valve, resulting in valve damage and further system contamination. These filters are pressure rated to 8,500 psi (586 bar) and use a µm or 0 µm stainless steel frit. An 8 distribution cone helps spread the flow of the mobile phase over the entire surface of the frit, while the.050 diameter thru-hole allows virtually unrestricted solvent flow rates. A-8 Precolumn Filter.49 Precolumn Filters A-4 0 µm Semi- Prep SST frit 0.5 µm or µm Porosity Frits Available Great Column Protection Feature Stainless Steel Bodies and Polymer-Encased Stainless Steel Frits A- Inline Solvent Filter Upchurch Scientific Precolumn Filters have.00 diameter thru-holes and 8 distribution cones for minimal band spreading and mixing. They feature stainless steel bodies, and pressure rated to 9,000 psi (60 bar) and both accept /6 OD tubing and standard 0- threaded high pressure fittings. Choose either the 0.5 µm or µm version to filter particulates from your flow path..49 A-00 µm SST frit.49 A-4 Inline Solvent Filter A-5 Precolumn Filter.49 A-6 Precolumn Filter A-0 µm SST frit A µm SST frit ORDER Ultra-Low Volume Precolumn Filters A µm Solvent Filter Assembly, with A-0 Frit 0.84 µl $ A-0x 0.5 µm Replacement Frits, Stainless Steel, 0-pk 0.6 µl.6 Precolumn Filters A-5 µm Solvent Filter Assembly, with A-0 Frit.4 µl $ 5.8 A µm Solvent Filter Assembly, with A-0 Frit. µl 5.8 A-0x µm Replacement Frits, Stainless Steel, 0-pk 0.74 µl.6 A-0x 0.5 µm Replacement Frits, Stainless Steel, 0-pk 0.6 µl.6 Inline Solvent Filters A- 0 µm Solvent Filter Assembly, with A- Frit. µl $ 5.8 A-4 µm Solvent Filter Assembly, with A-00 Frit 4.0 µl 5.8 A-00x µm Replacement Frits, Stainless Steel, 0-pk.4 µl.6 A-4 0 µm Replacement Frits, Stainless Steel, ea. 9.7 µl.6 *Swept volumes include/reflect theoretical frit volume values. TOP SELLER see starred products in price block.
7 Precolumn and Inline Filters Filters and Degassers Biocompatible Precolumn Filters 0.5 µm or µm Porosity Frits Available Great Column Protection Feature PEEK Bodies and PCTFE-surrounded PEEK Frits Upchurch Scientific Biocompatible Precolumn Filters have.00 diameter thru-holes and 8 distribution cones for minimal band spreading and mixing. The bodies of these filters are manufactured from biocompatible PEEK polymer versions and are pressure rated to 5,000 psi (45 bar). These filters are designed for use with /6 OD tubing, which can be connected to these filters using standard Fingertight fittings. Choose either the 0.5 µm or µm version to filter particulates from your flow path. Biocompatible Inline Filters µm and 0.5 µm Versions Available Upchurch Scientific A-40 and A-4 Inline Filters consist of a stainless steel body and two PEEK end fittings, one with a built-in µm or 0.5 µm PEEK frit. Both filters are pressure rated to 6,000 psi (44 bar), with maximum recommended flow rates of 5 ml/min for the A-40 Filter and 0 ml/min for the A-4 Filter. And, you get the added benefit of biocompatibility since all wetted surfaces are PEEK. When you need to replace the frit, simply dispose of the end fitting that contains the frit and replace it with a new one. The end fittings have 0- female ports to connect /6 OD or smaller tubing..6 End fitting with 00% PEEK frit A-40 Biocompatible Analytical Inline Filter Stainless steel body A-55 PEEK Precolumn Filter A-700 µm PEEK frit End fitting Note A-56 PEEK Precolumn Filter A µm PEEK frit Fittings All filters on these two pages have 0- internal threads for /6 OD tubing, conveniently allowing the use of our Fingertight Fittings. Use any of the all-polymer 0- Fingertight Fittings found on pages 4 0 with these filters. For the stainless steel filters, you may also use the 0- stainless steel fittings on page 9. Frits Any of the frits from pages 6 40 with an overall diameter of.47 or.54 can be used with the filters on this page. MicroFilters Our Precolumn and Inline MicroFilters are located on pages 4. TOP SELLER see starred products in price block. Increase The Life Of Your Column A precolumn filter placed between the sample injection valve and the HPLC column protects the column from particles originating in the sample and from pump and valve seal wear. Why use a precolumn filter when there is a frit at the head of the column itself? Because changing the column frit risks ruining the column as this frit cannot typically be changed without disturbing the column packing. A precolumn filter provides relatively inexpensive insurance against column damage, and changing its frit is easy. Biocompatible Precolumn Filters A-55 µm Solvent Filter Assembly, with A-700 PEEK Frit, Biocompatible.4 µl $ 5.70 A µm Solvent Filter Assembly, with A-70 PEEK Frit, Biocompatible. µl 5.70 A-700 µm Replacement Frit, PEEK Polymer, ea µl 7.6 A µm Replacement Frit, PEEK Polymer, ea. 0.6 µl 7.6 Biocompatible Inline Filters A-40 µm Biocompatible Filter Assembly, with A-49 End Fitting 7. µl $.5 A µm Biocompatible Filter Assembly, with A-48 End Fitting 5.9 µl.5 A-48x 0.5 µm PEEK Filter End Fittings, Black PEEK body, 0-pk 5.7 µl 55. A-49x µm PEEK Filter End Fittings, Natural PEEK body, 0-pk 6.9 µl 55. * Swept volumes include/reflect theoretical frit volume values. ORDER Use with polymer /6 nuts (0- threads) and any ferrule, found on pages 4 8.
8 Filters and Degassers Inline Filters Biocompatible Semi-Prep Inline Filters Versions for /6, /8, /6, /4 and 5/6 OD Tubing Our Biocompatible Semi-Prep Filters consist of a stainless steel body, two PEEK end fittings, and a separate PEEK frit. The A-40 and A-4 are pressure rated to 6,000 psi (44 bar), while the A-50 and A-5 are for higher flow, lower pressure applications. These filters are ideal for many higher flow analytical, semi-prep and preparative applications. Best of all, if the filter becomes clogged, simply unscrew the assembly, remove the frit and replace it. See price block for information on tubing sizes and fittings to use with these assemblies. Iso-Prep Filters Economical protection for preparative HPLC columns and injectors SFC & HPLC compatible Ideal for columns from. to 50 mm ID Stable to 8,000 psi (55 bar) This preparative inline filter holder with replaceable filter will help protect your investment against contamination. The filter element protects the column and maintains performance by safely removing particulate matter and insoluble material from the mobile phase and sample matrix. The filter unit can be placed in the flow path before the column with little or no effect on peak shape. This filter can also protect check valves, injectors, and detectors. Each filter assembly includes one 0.5 µm or.0 µm stainless steel frit A-40 Biocompatible Semi-Prep Inline Filter Semi-Prep Inline Filters Low Swept Volume The A-0 High Pressure Semi-Prep Filter has a swept volume of µl* and has been tested with water at flow rates up to 00 ml/min. At this rate the filter adds only 50 psi ( bar) additional back pressure. This product is pressure rated to 7,500 psi (57 bar) and is designed for use with standard 0- coned fittings and /6 OD tubing. Our A-60 is designed for use with /8 or /6 OD tubing, depending on the fittings selected. This filter has a swept volume of 5 µl and is pressure rated to,000 psi (07 bar). Each filter assembly consists of a two-part stainless steel holder and a replaceable frit. (One part of the holder is surface treated to prevent galling and to allow the frit to be easily removed.) The.750 diameter passivated stainless steel frit and the.050 (A-0) or.070 (A-60) diameter thru-hole allow high throughput. Each filter assembly includes one 0 µm frit (A-). Alternative options for both filters include the A- µm frit and the A-7 0 µm frit A-0 High Pressure Semi-Prep Inline Filter Shown with standard 0- stainless steel nuts and ferrules (not included) 0 µm Stainless Steel Frit.050 thru-hole ORDER Iso-Prep Filter Biocompatible Semi-Prep Inline Filters A-40 µm Biocompatible Filter Assembly, with OC-80 Frit 89 µl $ A-4 0 µm Biocompatible Filter Assembly, with OC-80 Frit 0 µl A-50 5 µm Biocompatible Filter Assembly, with OC-805 Frit 89 µl A-5 5 µm Biocompatible Filter Assembly, with OC-805 Frit 4 µl OC-80 µm PEEK Frit, Green Kel-F ring 46 µl 0. OC-80 0 µm PEEK Frit, Natural Kel-F ring 57 µl 0. OC µm PEEK Frit, Natural Kel-F ring 50 µl 0. Semi-Prep Inline Filters.56 Can use either 0.5 µm or.0 µm Stainless Steel Frit (included) A-0 0 µm Semi-Prep Filter Assembly 4, with A- Frit µl $ A-60 0 µm Semi-Prep Filter Assembly, with A- Frit 5 µl A-x 0 µm Stainless Steel Frits, Natural Tefzel (ETFE) ring, 0-pk 4 µl 6.5 A-x µm Stainless Steel Frits, Natural Tefzel ring, 0-pk µl 6.5 A-7x 0 µm Stainless Steel Frits, Natural Tefzel ring, 0-pk 5 µl 6.5 ISO-PREP FILTERs Qty mm Filter Holder with 0.5 µm Filter ea. $ mm Filter Holder with µm Filter ea mm Replacement Filter, 0.5 µm ea mm Replacement Filter, µm ea Use with polymer /6 nuts (0- threads) and any ferrule, found on pages 4 8. Use with the /8 /6 fittings (5/6-4 threads), found on page 6. Use with the /4 or 5/6 fittings (/-0 threads), found on page 6. 4 Use the standard /6 fittings (0- threads), found on pages 4 0. * Swept volumes include/reflect theoretical frit volume values.
Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159
Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 156 Inlet Solvent
More informationIDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159
Filters & Frits Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159
More informationFILTERS & COLUMN ACCESSORIES
156 FILTERS & COLUMN ACCESSORIES INLET SOLVENT FILTERS PAGE 157 INLINE SOLVENT FILTERS PAGE 160 PRECOLUMN FILTERS PAGE 163 FRITS PAGE 165 GUARD COLUMNS PAGE 170 SEE STARRED PRODUCTS FOR TOP SELLERS! Inlet
More information(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 .
Low Pressure FITTINGS & CONNECTORS Dimensions for /4-8 Upchurch Scientific eliminate the need to flange. This removable and reusable system provides several benefits: (pages 58 and 59) Convenience: Our
More informationOne-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.
Fingertight Fittings 4 One-Piece Fingertight Fittings Upchurch Scientific s original One-Piece Fingertight Fittings have 0-3 threads and are designed to be used with /6 OD tubing, except the M-645 (6-40,
More informationUpchurch High Pressure Fittings & Connectors
.010 thru-hole P-742 PEEK ZDV Union. 9 2.050 thru-hole P-760 PEEK ZDV Union P-704 PEEK ZDV Union. 9 2. 9 2 Fingertight Fittings ONE-PIECE FINGERTIGHT FITTINGS INTRODUCTION For Coned Ports For convenience
More informationUltra High Performance Fittings. Fittings Connectors Kits
Ultra High Performance Fittings Fittings Connectors Kits Ultra High Performance Fittings Introduction Ultra Performance Fittings Introduction high Temperature Versions Withstand Temperatures up to 200ºC
More information98 동방하이테크상사 T.(02) F.(02)
98 동방하이테크상사 http://www.allpump.co.kr T.(0)57-69 F.(0)57-69 00--7 troduction to Upchurch Scientific Valves Valves troduction Valves jection and Selection Valves for Pressures to,000 psi (69 bar) Switching
More informationMobile Phase Management
hplc columns & accessories hplc accessories Mobile Phase Management The solvent filtration apparatus rapidly filters and degasses HPLC and IC mobile phases. Description Part No. 1L Flask, 300mL Funnel,
More informationFittings SECTION 1 OF 4 SECTIONS ON FITTINGS
Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Deburring an Upchurch Scientific fitting in Oak Harbor, WA. The Very High Pressure (VHP) reusable fitting, VHP-320, is one of the exciting new products in the
More informationThis convenient system is made entirely of inert parts: glass, Baseline drift
95 P000515 55020 9960342 Supelco Mobile Phase Degassing System 55060-U Eliminates: Flow instabilities Mobile Phase Reservoir System Detector noise This convenient system is made entirely of inert parts:
More informationChrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter
HPLC ACCESSORIES IDEX Injection Valves IDEX Injection Valves Manual IDEX MANUAL INJECTION VALVES DESCRIPTION POS. SENSING SWITCH MAX PSI FITTING HIGH PRESSURE, ANALYTICAL (accepts a 22 gauge needle) FITS
More informationInstrument Accessories & Parts, Tubing & Connections
Instrument Accessories & Parts, Tubing & Connections ASI Piston Seals for Agilent HPLC Systems Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed
More informationFLUIDICS FITTINGS. 32 CONED FITTINGS 39 FLAT-BOTTOM FITTINGS 48 MarvelX 50 FITTINGS TOOLS 56 LARGE BORE FITTINGS 57 VHP FITTINGS 61 FITTINGS KITS
30 FITTINGS We offer a wide and diverse selection of fittings to meet your system requirements. A fitting refers to a complete product ready to assemble and connect tubing into a part. This could be a
More informationKontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos Four Valve Filtration / Delivery Caps
Kontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos. 953983-0047 953983-6347 Four Valve Filtration / Delivery Caps Kontes Article Nos. 953981-0047 953981-6347 Filter Size:
More informationHigh Pressure Valves. MX Series II Modules Manual Sample Injection Switching
High Pressure Valves MX Series II Modules Manual Sample Injection Introduction to High Pressure Valves HIGH Pressure Valves High Pressure Valves Introduction Rheodyne valves fit virtually any flow control
More informationSolvent Safety Bottle Caps
Solvent Safety Bottle Caps 2 Index Page 4 Page 6 Q-SERIES BOTTLE CAPS 1/4-28 UNF ports with optional on-off valves. A screw-in check valve and filter is available for a completely closed solvent supply
More informationseal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271
Restek Replacement Parts for Agilent HPLC Systems Meet or exceed OEM performance. Agilent part # qty. cat.# price Preventive Maintenance Kit Includes: rotor seal, needle seat, needle assembly, seat cap
More informationUP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule
One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,
More informationC OMPONENT S F O R A C L O S E D - S YS T E M HPL C
C OMPONENT S F O R A C L O S E D - S YS T E M HPL C TM Western Analytical Products, Inc hplc and gc columns and accessories fittings, tubing, valves, frits and filters lab and industrial safety products
More informationMobile Phase Accessories
NEW! Now available for GL-45 bottles! Bottles not included Waste Overflow Indicator Avoid messy pooling around mobile phase waste containers. Audible alarm instantly alerts user, preventing overflow. Compact,
More informationChromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO
8 SupelPRO Valves Order:.800..00 Technical Service:.800.9.0 Web: www.sigma-aldrich.com/supelco SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled,
More informationFITTINGS, LOOPS, AND VALVE ACCESSORIES
FITTINGS, LOOPS, AND VALVE ACCESSORIES Fittings Rheodyne offers a variety of fittings. They differ in material of construction, tubing size, and pressure rating. Materials/Biocompatibility. 316 stainless
More informationCONNECTORS VHP UNIONS LOW PRESSURE UNIONS THREADED ADAPTERS BARBED ADAPTERS PAGE 36 PAGE 40 PAGE 48 PAGE 58.
34 CONNECTORS VHP UNIONS PAGE 36 LOW PRESSURE UNIONS PAGE 40 THREADED ADAPTERS PAGE 48 BARBED ADAPTERS PAGE 58 SEE STARRED PRODUCTS FOR TOP SELLERS! i INTRODUCTION How to Order How to Order Direct from
More informationFOR ORDERING & DISTRIBUTOR INFORMATION
Testing Upchurch Scientific VHP unions in Oak Harbor, W. Eliminate tubing twist! The new Swivel Barb dapters won t twist peristaltic tubing as you tighten the adapter into a threaded port. See page 58
More informationFlow System Accessories
Flow System Accessories Fitting Systems MicruX is able to provide different accessories, from several suppliers, usually required for using the standard thinfilm (micro)electrodes in flowing liquids systems.»
More informationHPLC Tubing and Fittings Hints & Tips for the Chromatographer
HPLC Tubing and Fittings Hints & Tips for the Chromatographer By William S. Letter (Chiralizer Services, L.L.C.) INTRODUCTION: Setting up a high pressure liquid chromatography (HPLC) system to run trouble-free
More informationTECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure
TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like
More informationAgilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet
Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet 1. Description The Agilent Dynamax modular HPLC column system uses a unique technology, Dynamic, to maintain the structure of the packed
More informationSimplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.
Simplify your search for COLUMN HARDWARE Discover how to maximize results with Isolation Technologies column hardware and accessories that are specifically engineered to meet critical UHPLC, HPLC, and
More informationQuick Reference Guide. Supplies for Waters HPLC Systems
Quick Reference Guide Supplies for Waters HPLC Systems works with WATERS SHIMADZU THERMO/DIONEX BRUKER/VARIAN PERKINELMER CTC MORE Put innovation and quality to work on a wide range of GCs and HPLCs in
More informationUP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule
One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,
More informationÄKTA system Training Guide
ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector
More informationÄKTA system Training Guide. Purifier 100 / 10. amersham bio science
ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bio science ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector
More informationHIGH PRESSURE SWITCHING VALVES
HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available
More information16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry
2 Contents Solvent Safety Bottle Caps 4 Bottle Caps Selection Guide Q-Series Solvent Bottle Caps 6 1/4"-28 UNF threaded inlet lines with optional on-off valves T-Series Solvent Bottle Caps 8 Push-through
More informationHigh Pressure Valves. MX Series II Modules Manual Sample Injection Switching
High Pressure Valves MX Series II Modules Manual Sample Injection Switching Introduction to High Pressure Valves HIGH PRESSURE VALVES High Pressure Valves Introduction Rheodyne valves fit virtually any
More informationA.I.T FRANCE VICI ACCESSOIRES HPLC
Tubes pour HPLC PEEK OD and ID, see chart 1/16 +/- 0.05 mm (.002 ) 1/8 +/- 0.10 mm (.004 ) See chart Solid Color Coding The process used in extruding this type allows the olor to permeate through the entire
More informationLiquid Chromatography LC Consumables SSI-LC
Liquid Chromatography LC Consumables SSI-LC-10-2017 Table of Contents HPLC Pumps...3 LC-30AD... 3 LC-20AD / LC-20AB / LC-20ADXR... 4 LC-20AT... 4 LC-20Ai... 5 LC-10ADvp... 5 LC-10ATvp... 6 LC-10Ai... 6
More informationC L O S E D S Y S T E M S VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS
C L O S E D S Y S T E M S F O R S O L V E N T C O N T A I N M E N T VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS I N T R O D U C T I O N C L O S E D S Y S T E M S I N T R O D U C T I O N Minimize solvent
More informationPolymeric Fittings Low Pressure
INDEX PPS Nuts for Flat Bottom Fitting Details 59 PEEK Flangeless Nuts 62 Polyacetal Color Coded Flangeless Nuts 63 Polypropylene Flanged Fingertight Nuts 64 Unions 65 Bulkhead Unions 67 PEEK Tees, Crosses
More informationFITTINGS VHP FITTINGS CONED FITTINGS MICRO/NANO FLAT-BOTTOM FITTINGS PAGE 6 PAGE 10 PAGE 17 PAGE 21.
4 FITTINGS VHP FITTINGS PAGE 6 CONED FITTINGS PAGE 10 MICRO/NANO PAGE 17 FLAT-BOTTOM FITTINGS PAGE 21 SEE STARRED PRODUCTS FOR TOP SELLERS! i INTRODUCTION How to Order How to Order Direct from IDEX Health
More informationGLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913
GLENCO Syringes As a complement to the Spectra/Chrom chromatographic products, Spectrum manufactures precision syringes for sample injection and collection. These syringes are designed specifically to
More informationQuickSplit TM Flow Splitters
Quick TM Flow ters Quick TM Flow ter Features: Fluid resistor technology eliminates tedious adjustments to capillary tubing for split ratio optimization ratios are stable and reproducible, and not affected
More informationVERITY Purification Systems Build the perfect system to fit your research
VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC
More informationcheminert fittings Low Pressure Flangeless Tube End Fittings Flangeless tube end fittings 1/4-28
Low Pressure Flangeless Tube End Fittings Cheminert low pressure fittings are ideally suited for flow injection analysis, low pressure liquid chromatography, and stream sampling devices. They may be safely
More informationCLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS
CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS INTRODUCTION CLOSED SYSTEMS INTRODUCTION Through leaks, spills, and ventilation, an open solvent-using system will
More informationJour. Chromatography Fluid/Gas Transfer. Jour. CATALOG 20 INT. VICI Jour Chromatography Fluid/Gas Transfer
www.vici-jour.com VICI Jour Chromatography Fluid/Gas Transfer Jour Chromatography Fluid/Gas Transfer Jour VICI AG International Parkstrasse 2 6214 Schenkon Switzerland Phone +41 41 925 62 00 Fax +41 41
More informationHPLC Accessories. HPLC Columns HPLC Applications
HPLC Accessories Instrument Replacement Parts..........................332-337 Filters, Mobile Phase Accessories........................338-342 Column Heaters, Gas Trapping Systems......................343
More informationFixed Flow Splitter *
Fixed Flow * *Patent Pending Analytical Scientific Instruments Fluid resistor technology eliminates tedious adjustments to capillary tubing to change split ratios. Easy to use interchangeable fluid resistors
More informationOEM Capabilities. Experts in Fluid Technology
OEM Capabilities Experts in Fluid Technology Click-N-Seal Line Diba s Click-N-Seal fittings are the only multi-use fingertight fittings that cannot be over-tightened. The Click-N- Seal family of connectors
More informationOMNI-LOK TYPE S Chemically inert flangeless fitting with permanently attached PEEK or ETFE ferrules.
Fitting Systems 2 Index Page 4 Page 6 Page 8 Page 10 Page 12 Page 14 Page 15 Page 16 Page 17 OMNI-LOK TYPE P Chemically inert flangeless fitting with permanently attached PTFE ferrule. Ideal for repeat
More information14 Chromatography Columns
14 Chromatography Columns LC Columns Selection Guide Omnifit Labware columns offer the maximum performance for low to mid pressure liquid chromatography or flow chemistry applications. Simple to assemble,
More information78 동방하이테크상사 T.(02) F.(02)
78 동방하이테크상사 http://www.allpump.co.kr T.(0)7-9 F.(0)7-9 00--7 Introduction to Introduction Rheodyne valves fit virtually any high-pressure flow control application. As you ll see from the table below and
More information2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters
ADAPTERS Whether converting joint types, reducing or enlarging joints, or creating connections in a distillation apparatus, Kimble offers a comprehensive selection of adapters including bushing adapters,
More informationVALVES NEW MANUAL INJECTOR RHEBUILD KITS SAMPLE LOOPS MICRO VALVES PAGE 132 PAGE 136 PAGE 139 PAGE
VALVES NEW MANUAL INJECTOR PAGE RHEBUILD KITS PAGE 6 SAMPLE LOOPS PAGE 9 MICRO VALVES PAGE 6 SEE STARRED PRODUCTS FOR TOP SELLERS! Valve Overview VALVES 5 Rotary Shear Valves Rheodyne Rotary Shear Valves
More informationCLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS
CLOSED SYSTEMS FOR SOLVENT CONTAINMENT VAPOR AND SPILL CONTROL FOR LABORATORY SOLVENTS INTRODUCTION CLOSED SYSTEMS INTRODUCTION Through leaks, spills, and ventilation, an open solvent-using system will
More informationSample Pretreatment, Accessories
11 Sample Pretreatment, Accessories Sample pretreatment -------------------------- 144 Column protection----------------------- 145~147 Tubing parts ------------------------------ 148~151 Empty columns
More informationLC Instrument Replacement Parts
LC Instrument Replacement Parts /SSI Parts /SSI Pump Replacement Parts Alltech Pump Replacement Parts Misc. Pump Supplies Agilent Parts & Supplies for Agilent Instrumentation 1260 Infinity Isocratic LC
More informationFitting Systems. Leak-free, ee, simple-to-use 1/4-28 and M6 fitting types in
Fitting Systems Inside... Gripper Fitting System... 2 Assembling...2 Ordering...3 Flanged Fitting System... 4 Ordering...4 Inverted Cone Fitting System... 5 Ordering...5 Omnigrip Fitting System...6 Ordering...6
More informationAgilent InfinityLab Quick Change Valve G4235A Instructions
Agilent InfinityLab Quick Change Valve G4235A Instructions Contents Typical Application 2 Delivery Checklist 3 Specifications 4 Installing the Valve Heads 5 Agilent Technologies Typical Application This
More informationMitos P-Pump Accessories
Mitos P-Pump Accessories product datasheet page Flow Resistors 3 Flow Resistor Selection 6 Flow Resistor Kit 7 Mitos P Pump Vessel Holder Kit 9 Standard Vessel Compatibility Chart 11 Mitos P Pump Starter
More informationAgilent G5632 Valve Kit Instructions
Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Contents Typical Applications 2 Alternating Column Regeneration (2 position/10 port valves only) 2 Dual column selection 3 Sample
More informationPrimeLine TM HPLC Pumps
PrimeLine TM HPLC Pumps Isocratic Model 501 Gradient System 500G PrimeLine TM Isocratic and Gradient HPLC Pumps Feature: Self-priming pump head requires no manual priming Patented Floating Pump Seal design
More informationUniversal Pipette Tips Ultra-clear and certified RNase/DNase-free
Universal Pipette Tips Ultra-clear and certified RNase/DNase-free Universal Tips Tip Volume For Pipetter Bulk Rack 0.1-10 μl 5 - μl 0 0 Bag of 1000 500191 US$15 960 (10 racks of 96) 500192 US$30 Bag of
More informationGlycoChrom TM HPLC Analyzer. Hardware Installation and System Test
GlycoChrom TM HPLC Analyzer Hardware Installation and System Test PIN 410-5004 For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-8 00-424-6723) ,, Table of Contents
More informationHyperShear TM HPLC and UHPLC Mixers
HyperShear TM HPLC and UHPLC s Reduce baseline noise, increase sensitivity and improve gradient accuracy Decrease mixing and delay volume without sacrificing mixing efficiency Increase reaction efficiency
More informationCompetitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares
Competitive Comparison Maximize Performance and Minimize Maintenance with LC Spares high-quality spare parts and preventative maintenance kits Regular replacement of crucial parts can help keep your HPLC
More informationNEW? HPLC ACCESSORIES. What s. look for this circle
HPLC ACCESSORIES Instrument Accessories & Parts..............327-332 Tubing & Connections.......................332-335 Tools & Maintenance.........................336-337 Mobile Phase Accessories Bottle
More informationKEY FEATURES. Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups
CapTite Microfluidic Construction Kits KEY FEATURES Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups Routing fluids can be one of
More informationAdjustable Flow Splitter *
Adjustable Flow Splitter * *Patent Pending Analytical Scientific Instruments Adjustable metering valve enables precise direct control over split ratios. Fluid resisr technology eliminates tedious adjustments
More informationMODEL 905V OPERATING INSTRUCTIONS
MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions
More informationReciPro Liquid Metering Pumps. Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options
ReciPro Liquid Metering Pumps Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options ReciPro HP Series Eldex metering pumps can be used wherever precise flow rate
More informationPhysiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN
80-6000-32 Physiological Calibration Standard II 80-2037-62 Calibration standard physiological fluid 80-2037-61 CALIBRATION STANDARD PROTEIN HYDROLYSATE 80-2104-53 1/8" FLANGELESS FITTING (PK 5) 80-2108-41
More informationFluoro plastic products
Volumetric flasks, PFA, class A 472 High transparency, individually calibrated ring-mark. Tolerances class A according to DIN EN ISO 1042. With lasered lot.number. Supplied with PFA screw-caps. Screw-caps
More informationVACUUM FILTRATION
VACUUM FILTRATION Introduction Glass Microfiltration: Support Systems mm Glass Microanalysis Holders mm Glass Microanalysis Holders 7 mm Glass Microanalysis Holders 7 mm Glass: All-Teflon seal 7 mm Glass:
More informationYour Essential Resource for INFINITYLAB LC SUPPLIES
Your Essential Resource for INFINITYLAB LC SUPPLIES ACROSS THE LAB, AROUND THE WORLD, WITH YOU EVERY STEP OF THE WAY. Real stories from the lab. WHO WE ARE. WHAT WE DO. Whatever your lab needs, Agilent
More informationDilutor Module for TriPlus RSH
Thermo Scientific Dilutor Module for TriPlus RSH Instruction Manual Additional section of the TriPlus RSH User Guide and Hardware Manual 31709661 Revision A December 2015 2015 Thermo Fisher Scientific
More information10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual
1260 Infinity Binary Pump User Manual 10 Maintenance Introduction to Maintenance and Repair 148 Warnings and Cautions 149 Cleaning the Module 151 Overview of Maintenance and Simple Repairs 152 Maintenance
More informationAgilent SD-1 Purification System ml/min
Agilent SD-1 Purification System - 200 ml/min Introduction Installation of the Capillary Kit This technical note shows you how to install the Stainless Steel Capillary Kit (SD- 1 Purification System -
More informationIndex Page 4. Page 6. Page 8. Page 10. Page 12. Page 14. Page 15. Page 16. Page 17. Page 18. Page 20.
Fitting Systems 2 Index Page 4 Page 6 Page 8 Page 10 Page 12 Page 14 Page 15 Page 16 Page 17 OMNI-LOK TYPE P tting with permanently attached PTFE ferrule. Ideal for repeat connect/disconnect. Our highest
More informationGE Healthcare. Valve INV-917. Instructions
GE Healthcare Valve INV-917 Instructions INV-917 2 1 3 7 4 5 6 Important user information All users must read this entire manual to fully understand the safe use of Valve INV-917. Important! Valve INV-917
More informationAgilent Valve Kit G4231A/B and G4232A/B/C
Agilent Valve Kit G4231A/B and G4232A/B/C Instructions Contents Typical Applications 2 Dual column selection (G4231A/B or G4232A/B/C) 2 Sample enrichment and sample cleanup (G4231A/B or G4232A/B/C) 2 Alternating
More information850 Professional IC. AnCat MCS Manual EN
850 Professional IC AnCat MCS 2.850.3030 Manual 8.850.8052EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com 850 Professional IC AnCat
More informationLC Accessories Instrument Replacement Parts For Agilent HPLC Systems For PerkinElmer HPLC Systems For Shimadzu HPLC Systems...
LC Accessories Instrument Replacement Parts For Agilent HPLC Systems...299 302 For PerkinElmer HPLC Systems...303 For Shimadzu HPLC Systems...304 305 For Thermo HPLC Systems...306 For Waters HPLC & ACQUITY
More informationPOLYMED CATALOGUE 2013 POLYCARBONATE STOPCOCKS MANIFOLDS - CONNECTORS
CATALOGUE 2013 POLYCARBONATE STOPCOCKS MANIFOLDS - CONNECTORS General Information COMPLIANCE PRODUCT The Luer taper fittings are conform to standard ISO 594-1 for syringes, needles and other medical devices.
More informationMaintaining Your Agilent 1100 Series HPLC System
Operate your lab at peak performance Troubleshoot difficult problems Select the right Agilent supplies For detailed information about supplies from Agilent, please contact your local Agilent sales representative,
More informationCTC Analytics Service Note June 2015 PAL-xt: Material change for Rotor Seal of C2V-3006-CTC
To: Dealer/OEM orld-ide, PAL Systems Platform PAL and PAL-xt Systems From: Toni Eberwein Date: June 19, 2015 Subject: change for rotor seal C2-30R (for valve C2V-300D-CTC) CTC Alytics Service Note June
More informationACQUITY UPLC I-Class System with 2D Technology
ACQUITY UPLC I-Class System with 2D Technology The Waters ACQUITY UPLC I-Class System with 2D Technology allows chemists to increase sensitivity and selectivity, eliminate unwanted interferences, characterize
More informationPhenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals
Phenomenex Exclusive! Easy Seals Inlet Base Seals Guaranteed fit for Agilent 5000, 6000 and 7000 Series GCs The Easy Seals Gold Standard No Strained Hands No Troublesome Washers or Adaptors Continuing
More informationSAFETY. glassware solutions precision glassware solutions precision glassware solutions precision g
SAFETY KimCote Choose KimCote plastic-coated glassware for an added measure of safety. KimCote protective glassware coating goes beyond traditional coatings. Should a break occur, it will reduce the hazards
More informationConnectors & Connectors with valves
Connectors & Connectors with valves Inside... Omnifit Cap instructions... Small Bore Connectors... 3 with valves... Large Bore Connectors... 5 with valves... 5 T Block Connector... 6 In-line Connectors...
More informationMiniature Multimedia Valves
2 Inert Isolation PTFE 3-Way Solenoid Valve Series 1 The Series 1 diaphragm type valve has a low internal volume and rapid response time, which enables users to get readings quickly for their analysis.
More informationVarian Dual Chamber Dynamic Mixer Instruction Manual
Varian Dual Chamber Dynamic Mixer Instruction Manual Installation Category II Pollution Degree 2 Safety Class 1 (EN 61010-1) Publication no. 0391467400 Issue 5 February 2009 Varian, Inc. Serving Industries
More informationTHREE-PIECE BALL VALVES H-500 SERIES
THREE-PIECE BALL VALVES H-500 SERIES H-500 FEATURES 3-piece heavy-duty ball valves with: Precision Investment cast body in CF8M stainless steel Precision Investment cast end caps in CF3M stainless steel
More informationVICI JOUR novinky říjen 2011
Science Instruments and Software, s.r.o. VICI JOUR novinky říjen 2011 PUB#: DI311013 CHROMATOGRAPHY & FLUID/GAS TRANSFER NEW! from VICI JOUR SPECS Material Insert PTFE O-ring EPDM Ferrules ETFE Closure
More informationHyperShear TM HPLC Mixers
HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex sheer mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume
More informationAccuracy Starts Here. Agilent Captiva Filtration Selection Guide
Accuracy Starts Here Agilent Captiva Filtration Selection Guide TAbLe of CoNTeNTS Tips & Tools Learn the core concepts surrounding Solid Phase Extraction and best practices for Sample Prep. View the video
More informationHPLC Essentials Genuine Restek Replacement Parts for HPLC Systems
HPLC Essentials Genuine Replacement Parts for HPLC Systems 20 YEARS Turning Visions into Reality 800-356-1688 814-353-1300 2 Becky Wittrig HPLC Products Marketing Manager 4+ years of service! did you know?
More informationAgilent 1290 Infinity II Ultra Low Dispersion Kit
Agilent 1290 Infinity II Ultra Low Dispersion Kit Technical Note 1290 Infinity II Ultra Low Dispersion Kit - Technical Note In this note we describe how to install the Agilent 1290 Infinity II Ultra Low
More information