Transcription

1 98 동방하이테크상사 T.(0)57-69 F.(0)

2 troduction to Upchurch Scientific Valves Valves troduction Valves jection and Selection Valves for Pressures to,000 psi (69 bar) Switching and Shut-Off Valves for Pressures to 500 psi ( bar) Directly Connect /6 or /8 OD Tubing with Flangeless Fittings (included) Manual and Actuated Versions Upchurch Scientific Valves are available for /6 or /8 OD tubing in sample injection or six-way flow selection versions. These valves have completely biocompatible flow paths and are perfect for systems where the pressure does not exceed 500,000 psi ( 69 bar), including flow injection analysis (FIA) and some chromatography applications. These valves come in manual (with or without a bulkhead mounting option) and electronically actuated versions. For more details on these valves, please see pages The Valve series also includes our (rated to 500 psi, bar) which offer several options for directional flow control. The most popular is the L style a two-way switching valve that could be used for mobile phase, column or detector selection between two inlets or outlets. Use the T style valve with a plug to change a three-way open connection to a two-way selection valve. The D style valve is a two position four-way switching valve where adjacent ports are connected by a flow path which rotates 90 to change position. Applications for this valve include protection of column or other sensitive instrument components during a cleaning cycle. These biocompatible four-port switching valves are available for manual control or mounted onto an electronic actuator. Polymer inline shut-off valves are also available for /8 or /6 OD tubing to quickly turn a flow stream on or off. For more information on medium-pressure Switching and Shut-Off valves, please see pages 0 0. Micro-Metering and Micro-Splitter Needle Valves Fine Control of Flow in Two-way or Three-way Valves Applicable to a Wide Range of Applications, including terfacing LC/MS Systems Ability to Adjust and Change Split Flow Ratio Versions for Capillary up to /8 OD Tubing Upchurch Scientific Needle Valves control flow of either the output of a two-port valve (Micro-Metering) or on the split stream of a three-port valve (). Use one of these valves to regulate gas flow in a helium sparging system or to split post-column flow to a mass spectrometer. Several versions are available for connecting different tubing sizes, and biocompatible equivalents of each are offered. For more information on the different valve styles and functions, please see pages Electronic Actuators With Factory Premounted Valve Safety Tested and Rated to Conform to ETL, CSA, and CE Specifications All of our valves listed on pages 0 0 are available premounted on compact Electronic Actuators to automate valve positioning. Our valves are coupled with a DC gear motor which offers outstanding rotational accuracy and low actuation times. Upchurch Scientific actuated valves can be conveniently operated by keypad or computer controlled through contact closure and RS- communication. LED indicators on the actuator keypad specify valve position. Additionally, valves may be multiplexed (daisy-chained) for custom automation solutions when using RS- communication. Each actuator is provided with an inline power adapter which allows operation from both 0/0V (North American) and 0/0V (European) AC power. All actuators come with a one-year parts and labor warranty. DC Gear Motor Actuated Valves The user s guide, shipped with each actuated valve, is also available online: DC Gear Motor Actuator Valves User Guide at Prime/Purge Valves Upchurch Scientific also offers two styles of pump Prime/Purge Valves, one for use with Waters HPLC instruments and a universal low pressure version. Both feature easy, luer-actuated operation, and are on page 06. Actuator dimensions, excluding valve (H x W x D): 7mm x 56mm x 65mm (.8 x. x 6.5 ) Actuators cannot be purchased separately they are only available custom programmed for the appropriate premounted valve. Please contact Upchurch Scientific for information on optional stepper motor actuators. Order Tel: /

3 jection Valves jection Valves Biocompatible and ert Low Swept Volume Minimal Dispersion Upchurch Scientific 6-Port jection Valves feature easy, external sample loop customization. Simply clean-cut a piece of tubing that represents the volume of sample you wish to inject, taking into account the port-to-port volume of the valve. Please refer to the Tubing ternal Diameters and Volumes chart on page 7 for assistance in calculating the volume of a length of tubing. Two biocompatible injection valve options are available: Long-Life Ceramic Featuring ceramic-to-ceramic sealing surfaces, these new long-life valves have been tested to over one million actuations with no change in performance.* The wetted materials are chemically resistant ceramic and PEEK polymer and the valves are rated to 500 psi ( bar). Each valve includes /-8 Flangeless Fittings for /6 OD tubing. Economical Polymer These economical valves have chemically resistant Vespel and DuPont Teflon brand resin wetted surfaces and are rated for a maximum pressure of,000 psi (69 bar). Each valve includes /-8 Flangeless Fittings for /6 or /8 OD tubing. Both valve options are available in three configurations: standard manual, bulkhead mountable manual and actuated. A valve mounting bracket (M-65-) is listed on page 0, and bulkhead mounting specifications are available at Refer to page 99 for information regarding the DC Gear motor actuators. Please contact Upchurch Scientific for stepper motor actuated options, as well as custom configurations for instrument manufacturers. High pressure injection valve options are available starting on page 78. * Tested using room-temperature water as the solvent. jection Port Adapter Our simple, biocompatible adapter converts any /-8 flat-bottom port into a port that can accept a standard gauge HPLC injection needle. This injection port adapter is adjustable, so you can create a snug fit around the needle to prevent any leaking of the analyte. addition, this product features an internal stop that prevents you from inserting the needle too far, eliminating the possibility of damaging the valve with the needle tip. P-96 Replaceable Tubing and Ferrule Assembly (cluded) V-6-DC Viewpoint from rotary knob Pump Sample (Needle Port) Pump Position A (LOAD) V-5-DC Flow path of jection Valve (highlighting flow through sample loop in each position) jection Valves, manual M-60 jection Valve, Ceramic, for /6 OD tubing.00 thru-hole, 6.9µL swept volume, Black M-6 Bulkhead version of M-60 V-50 jection Valve, Polymer, for /6 OD tubing.00 thru-hole, 5.µL swept volume, Black V-5 Bulkhead version of V-50 V-50 jection Valve, Polymer, for /8 OD tubing.06 thru-hole,.7µl swept volume, Red V-5 Bulkhead version of V-50 V-0 5/6 Allen Wrench (replacement) Sample Waste 5 Position B (INJECT) jection Valves, actuated V-5 Manual Valve Dimensions (excluding fittings) Valve Type Sealing Surfaces Dimensions (L x W) Standard Bulkhead Mountable Polymer Ceramic Polymer Ceramic Width of the knob, which is slightly wider than the valve body..7 x. (69. x.5 mm).75 x.0 (69.8 x.0 mm).9 x. (7. x.5 mm).00 x.0 (76. x.0 mm) Sample (Needle Port) Sample Waste 00 Adapter Body P-95 jection Port Adapter Needle Port Order Tel: / V-5-DC Actuated version of V-5, DC Gear (premounted) V-5-DC Actuated version of V-5, DC Gear (premounted) V-6-DC Actuated version of M-6, DC Gear (premounted) jection Port Adapter P-95 Adjustable jection Port Adapter P-96 Replacement Tubing/Ferrule Assembly Comes complete with P-5/P-00 Flangeless Fittings. Per pathway. Three pathways per valve. Comes complete with P-5/P-0 Flangeless Fittings. Actuated valves also include: () serial port adapter; () each RS- and contact closure communications cables; () power adapter; () each North American style and European style power cord. DC gear actuated valves come with a communication cable for multiplex (daisy-chain) operations.

4 Selection Valves V--DC V-7-DC 6-Way Selection Valves Biocompatible and ert Low Swept Volume Excellent Choice for Mobile Phase Selection Patented Upchurch Scientific 6-Way Selection Valves have a common inlet (or outlet) port connected to six different ports. Use these valves to select between multiple solvent reservoirs without having to disconnect and reconnect lines (see Application Note). Or, use two valves in conjunction with each other to serve as a column selection system in a moderate pressure semi-prep or high-flow analytical application. These ceramic valves are ideal for biocompatible instrumentation and can be used in flash chromatography for the preparation of proteomics samples. Two biocompatible selection valve options are available: V-0 Long-Life Ceramic Featuring ceramic-to-ceramic sealing surfaces, these new long-life valves have been tested to over one million actuations with no change in performance.* The wetted materials are chemically resistant ceramic and PEEK polymer and the valves are rated to 500 psi ( bar). Each valve includes /-8 Flangeless Fittings for /6 OD tubing. Use our 6-Way Selection Valve to easily select different solvents with an isocratic pump. The setup below involves an isocratic pump used for two separate assays, each requiring a prerinsing step prior to use. Using our Selection Valve in this setup, the system can be primed with the solvent in the first reservoir. Then, solvent from the second reservoir can be used as the mobile phase for the first application. Later, the system can be rinsed with an intermediate buffer solution from the third reservoir, followed by switching over to the second mobile phase in reservoir number. At the end of the day, the system can be rinsed with water from a fifth reservoir to avoid the possibility of precipitation on wetted surfaces. Follow this rinse with a final rinse of methanol from the sixth reservoir for system storage. # Mobile Phase 6-Way Valve # Priming Solution Economical Polymer These economical valves have chemically resistant Vespel and DuPont Teflon brand resin wetted surfaces and are rated for a maximum pressure of,000 psi (69 bar). Each valve includes /-8 Flangeless Fittings for /6 or /8 OD tubing. If your application does not require all six outer ports, seal the extra port(s) with any flat-bottom /-8 plug from page 60. Both valve options are available in three configurations: standard manual, bulkhead mountable manual and actuated. A valve mounting bracket (M-65-) is listed on page 0, and bulkhead mounting specifications are available at Refer to page 99 for information regarding the DC Gear motor actuator. Dimensions of the manual selection valves are the same as that of the injection valves please refer to the dimensions chart on page 00. Please contact Upchurch Scientific for stepper motor actuated options, as well as custom configurations for instrument manufacturers. High pressure selection valve options are available starting on page 78. * Tested using room-temperature water as the solvent. # termediate Buffer Solution # Mobile Phase Isocratic Pump #5 Rinse Water #6 MeOH Sample jection Valve 6-Way Selection Valves, Manual M-70 6-Way Selection Valve, Ceramic, for /6 OD tubing.00 thru-hole, 6.µL swept volume, Black M-7 Bulkhead version of M-70 V-0 6-Way Selection Valve, Polymer, for /6 OD tubing.00 thru-hole,.5µl swept volume, Black V- Bulkhead version of V-0 V-0 6-Way Selection Valve, Polymer, for /8 OD tubing.06 thru-hole, 8.µL swept volume, Red V- Bulkhead version of V-0 V-0 5/6 Allen Wrench (replacement) Waste medium Pressure 6-Way Selection Valves, actuated Data Recording Device V--DC Actuated version of V-, DC Gear (premounted) V--DC Actuated version of V-, DC Gear (premounted) V-7-DC Actuated version of V-7, DC Gear (premounted) Comes complete with P-5/P-00 Flangeless Fittings. Comes complete with P-5/P-0 Flangeless Fittings. Actuated valves also include: () serial port adapter; () each RS- and contact closure communications cables; () power adapter; () each North American style and European style power cord. DC gear actuated valves come with a communication cable for multiplex (daisy-chain) Order Tel: / operations. 0

5 Switching and Shut-Off Valves -Port Shut-Off Valves Switching Valve Applications With three versions to choose from, Upchurch Scientific Switching Valves offer many flow distribution options. Each valve has a low swept volume, can withstand pressures to 500 psi ( bar) and is chemically inert and biocompatible. The PEEK and DuPont Teflon brand resin construction results in a valve as durable as it is economical. Each V-00 Series Switching Valve has.00 thru-holes and is supplied with Flangeless Fittings for use with /6 OD tubing. To use these valves with /8 OD tubing, simply replace the supplied fittings with /-8 Flangeless Fittings found on page 57. You may notice a slight back pressure at higher flow rates, due to the.00 thru-holes in these valves. Protect sensitive system components (such as a column) during a cleaning cycle with our Diagonal Flow Switching Valve ( D ). This valve eliminates the need to remove, plug and reconnect a low pressure column (see below). Pump To operate, all ports must be either connected to a line of your system or plugged. Built-in positioning detents allow these valves to snap into place, ensuring the thru-hole is properly aligned. V-0D-DC Position Each of the Upchurch Scientific -Port is available in standard manual and bulkhead mountable manual configurations. Bulkhead mounting specifications are included and are also available at The bulkhead mountable manual configuration can also be mounted on our M-65- Valve Bracket (see below). DC gear motor actuated versions are also available please see page 0 for actuator information. Selected applications for our are listed on the following page. However, there are also several other possible uses for these valves. Please contact your local authorized Distributor or Upchurch Scientific directly to discuss your particular application. Valve Brackets Mount the bulkhead mountable manual valves presented on pages 00 0 with these Brackets. Once mounted, a valve will be positioned horizontally. Extra holes are provided for valve accessories. Made of sturdy anodized aluminum, these brackets can be attached to any lab surface. Each bracket comes with the required valve mounting hardware and instructions. -Way Diagonal Flow (V-00D, V-0D, V-0D-DC) Right Angle Flow (V-00L, V-0L, V-0L-DC) -Way Flow (V-00T, V-0T, V-0T-DC) Swept Volume V-00D -Way Diagonal Flow Switching Valve.µL V-00L Right Angle Flow Switching Valve 6.µL V-00T -Way Flow Switching Valve V-0D Bulkhead Version of V-00D.µL V-0L Bulkhead Version of V-00L 6.µL V-0T Bulkhead Version of V-00T V Allen Wrench (replacement) Swept Volume V-0D-DC Actuated version of V-0D,.µL V-0L-DC Actuated version of V-0L, 6.µL V-0T-DC Actuated version of V-0T, Valve Bracket.9 shown with an M-6 jection Valve (not included) 0 Order Tel: / V-00L Valve # M-65- M-65- Mounting Bracket for (this page) Mounting Bracket for jection and Selection Valves (pages 0 0) Comes complete with P-8BLK/P-0 Flangeless Fittings. L and T valve versions also include a P-09 Plug. Actuated valves also include: () serial port adapter; () each RS- and contact closure communications cables; () power adapter; () each North American style and European style power cord. DC gear actuated valves come with a communication cable for multiplex (daisy-chain) operations..5 diameter.07 V-00L Valve # # Plug switching application may require the flexibility of routing the column effluent to both detectors simultaneously while retaining the ability to isolate each detector. Use our -Way Flow Switching Valve ( T ), plugging off the fourth port with the included plug (see right). # Plug Position P-7 PEEK Shut-Off Valve.50 P-78 ETFE Shut-Off Valve Position Your detector Medium pressure -Port, Actuated M-65- Valve Bracket, Medium pressure -Port, Manual.0 Position A typical application for a Right Angle Flow Switching Valve ( L ) is column switching, allowing two columns to use one detector. switching is another common application for this valve (see below). Plug off the extra port with the included plug. Switching Valve Options: Please contact Upchurch Scientific for stepper motor actuated options, as well as custom configurations for instrument manufacturers. High pressure switching valve options are available starting on page 78. Connect semi-rigid or rigid tubing, such as PEEK, stainless steel or DuPont Teflon brand resin, with the /-8 Flangeless Fittings provided. Soft tubing, such as Pharmed or Tygon (see pages ), may be connected to these valves using our /-8 barbed adapters, found on page 8. n lum Co n lum Co V-0L Standard manual valves (V-00D, V-00L and V00T) measure.80 (5.7 mm) in length. Bulkhead versions (V-0D, V-0L and V-0T) are.8 (55. mm) long.. Pump Stop a flow stream quickly with Upchurch Scientific biocompatible Shut-Off Valves. The bodies are manufactured from either PEEK or Tefzel (ETFE) with a Kel-F rotor, making them highly resistant to chemical attack. The blue colorant used in some valve configurations has proven not to leach out with common HPLC solvents. Three Flow Configurations to Choose From Biocompatible Flow Paths For Applications Biocompatible, All-Polymer Flow Path Available for /6 and /8 OD Tubing # # Position stall a Shut-Off Valve between the solvent reservoir and pump. Then, when it is necessary to disconnect the solvent line, a simple twist of the valve lever eliminates the potential of a hazardous spill. # # Position Shut-Off Valves # ternal Material OD Tubing Thru-hole Volume P-7 PEEK, Natural /6.00.5µL P-7 PEEK, Natural / µL P-78 ETFE, Blue /6.00.5µL P-78 ETFE, Blue / µL P-7 ETFE, Natural / µL # Position Maximum internal volume, with valve fully open. Comes complete with P-5/P-00 Fittings. Comes complete with P-5/P-00 Fittings. Comes complete with P-5/P-00N Fittings. Pressure Rating 500 psi ( bar) 500 psi ( bar) 500 psi ( bar) 500 psi ( bar) 500 psi ( bar) Order Tel: /

6 Switching and Shut-Off Valves -Port Shut-Off Valves Switching Valve Applications With three versions to choose from, Upchurch Scientific Switching Valves offer many flow distribution options. Each valve has a low swept volume, can withstand pressures to 500 psi ( bar) and is chemically inert and biocompatible. The PEEK and DuPont Teflon brand resin construction results in a valve as durable as it is economical. Each V-00 Series Switching Valve has.00 thru-holes and is supplied with Flangeless Fittings for use with /6 OD tubing. To use these valves with /8 OD tubing, simply replace the supplied fittings with /-8 Flangeless Fittings found on page 57. You may notice a slight back pressure at higher flow rates, due to the.00 thru-holes in these valves. Protect sensitive system components (such as a column) during a cleaning cycle with our Diagonal Flow Switching Valve ( D ). This valve eliminates the need to remove, plug and reconnect a low pressure column (see below). Pump To operate, all ports must be either connected to a line of your system or plugged. Built-in positioning detents allow these valves to snap into place, ensuring the thru-hole is properly aligned. V-0D-DC Position Each of the Upchurch Scientific -Port is available in standard manual and bulkhead mountable manual configurations. Bulkhead mounting specifications are included and are also available at The bulkhead mountable manual configuration can also be mounted on our M-65- Valve Bracket (see below). DC gear motor actuated versions are also available please see page 0 for actuator information. Selected applications for our are listed on the following page. However, there are also several other possible uses for these valves. Please contact your local authorized Distributor or Upchurch Scientific directly to discuss your particular application. Valve Brackets Mount the bulkhead mountable manual valves presented on pages 00 0 with these Brackets. Once mounted, a valve will be positioned horizontally. Extra holes are provided for valve accessories. Made of sturdy anodized aluminum, these brackets can be attached to any lab surface. Each bracket comes with the required valve mounting hardware and instructions. -Way Diagonal Flow (V-00D, V-0D, V-0D-DC) Right Angle Flow (V-00L, V-0L, V-0L-DC) -Way Flow (V-00T, V-0T, V-0T-DC) Swept Volume V-00D -Way Diagonal Flow Switching Valve.µL V-00L Right Angle Flow Switching Valve 6.µL V-00T -Way Flow Switching Valve V-0D Bulkhead Version of V-00D.µL V-0L Bulkhead Version of V-00L 6.µL V-0T Bulkhead Version of V-00T V Allen Wrench (replacement) Swept Volume V-0D-DC Actuated version of V-0D,.µL V-0L-DC Actuated version of V-0L, 6.µL V-0T-DC Actuated version of V-0T, Valve Bracket.9 shown with an M-6 jection Valve (not included) 0 Order Tel: / V-00L Valve # M-65- M-65- Mounting Bracket for (this page) Mounting Bracket for jection and Selection Valves (pages 0 0) Comes complete with P-8BLK/P-0 Flangeless Fittings. L and T valve versions also include a P-09 Plug. Actuated valves also include: () serial port adapter; () each RS- and contact closure communications cables; () power adapter; () each North American style and European style power cord. DC gear actuated valves come with a communication cable for multiplex (daisy-chain) operations..5 diameter.07 V-00L Valve # # Plug switching application may require the flexibility of routing the column effluent to both detectors simultaneously while retaining the ability to isolate each detector. Use our -Way Flow Switching Valve ( T ), plugging off the fourth port with the included plug (see right). # Plug Position P-7 PEEK Shut-Off Valve.50 P-78 ETFE Shut-Off Valve Position Your detector Medium pressure -Port, Actuated M-65- Valve Bracket, Medium pressure -Port, Manual.0 Position A typical application for a Right Angle Flow Switching Valve ( L ) is column switching, allowing two columns to use one detector. switching is another common application for this valve (see below). Plug off the extra port with the included plug. Switching Valve Options: Please contact Upchurch Scientific for stepper motor actuated options, as well as custom configurations for instrument manufacturers. High pressure switching valve options are available starting on page 78. Connect semi-rigid or rigid tubing, such as PEEK, stainless steel or DuPont Teflon brand resin, with the /-8 Flangeless Fittings provided. Soft tubing, such as Pharmed or Tygon (see pages ), may be connected to these valves using our /-8 barbed adapters, found on page 8. n lum Co n lum Co V-0L Standard manual valves (V-00D, V-00L and V00T) measure.80 (5.7 mm) in length. Bulkhead versions (V-0D, V-0L and V-0T) are.8 (55. mm) long.. Pump Stop a flow stream quickly with Upchurch Scientific biocompatible Shut-Off Valves. The bodies are manufactured from either PEEK or Tefzel (ETFE) with a Kel-F rotor, making them highly resistant to chemical attack. The blue colorant used in some valve configurations has proven not to leach out with common HPLC solvents. Three Flow Configurations to Choose From Biocompatible Flow Paths For Applications Biocompatible, All-Polymer Flow Path Available for /6 and /8 OD Tubing # # Position stall a Shut-Off Valve between the solvent reservoir and pump. Then, when it is necessary to disconnect the solvent line, a simple twist of the valve lever eliminates the potential of a hazardous spill. # # Position Shut-Off Valves # ternal Material OD Tubing Thru-hole Volume P-7 PEEK, Natural /6.00.5µL P-7 PEEK, Natural / µL P-78 ETFE, Blue /6.00.5µL P-78 ETFE, Blue / µL P-7 ETFE, Natural / µL # Position Maximum internal volume, with valve fully open. Comes complete with P-5/P-00 Fittings. Comes complete with P-5/P-00 Fittings. Comes complete with P-5/P-00N Fittings. Pressure Rating 500 psi ( bar) 500 psi ( bar) 500 psi ( bar) 500 psi ( bar) 500 psi ( bar) Order Tel: /

7 Micro-Splitter Valve Applications & Notes Upchurch Scientific offers a line of Micro-Splitter Needle Valves designed to accurately split and control a low-flow stream off a single incoming supply. P-70 The biocompatible are perfect for LC-MS and other multidetector systems and fraction collectors. The ideal placement of these valves is on the effluent side of the detector flow cell, at a maximum pressure of. Choose between /-8 and 0- threaded versions. A valve is also available to accommodate applications involving capillary tubing. M-05S The High Pressure are designed to operate under pressures up to,000 psi (76 bar). These products are well suited for running two analytical devices in parallel. The High Pressure Capillary may also be used to adapt an analytical HPLC system to handle microbore applications. P-50 Our Graduated Valves offer many of the benefits and features of our original, plus the ability to adjust and set the split flow to repeatable settings. This allows documentation of settings and the resulting flow rates for easier method development. The graduations also make it easier to employ the valve in a system used to run multiple analyses that require different split flow rates. Choose from regular High Pressure and Capillary versions. All have been tested at flow rates to 00mL/min., with a maximum resulting pressure drop of only 5 psi (. bar). his valve has a MicroTight 6- threaded fitting on the split stream. Select the appropriately sized T MicroTight Tubing Sleeve from page 8 to connect your capillary tubing. Preasure drop measured when valves fully opened. P-5 Micro-Splitter Valve Thumbscrew Back Pressure Considerations Our are designed to work when both effluent flow path pressures are nearly identical. However, the split flow path will often have higher back pressure than the waste flow path, making it hard to achieve any split flow at all. There are two possible solutions. Place a back pressure regulator (see pages 08 0) on the waste flow path that is equal to or slightly greater than the pressure on the split flow path. Or, switch the two effluent pathways such that the split flow pathway is attached to the waste port on the valve and the waste flow pathway is attached to the split port on the valve. This second method may result in a loss of adjustment sensitivity. For fine control of fluid flow rates, our Micro-Metering Needle Valves can reduce outgoing flow to as low as.5µl/min*. These needle valves are perfect for use with peristaltic pump fluid-transfer applications, mass spectrometry, and fraction collection. Upchurch Scientific can also be used to regulate gas flow in helium sparging lines and as a flow-dependent variable back pressure regulator. For flow independent regulation of back pressure, please see pages Please request our Flow Control Valve Applications Guide for more details. Flow path materials are PEEK polymer and Teflon (O-rings). All versions of this valve have.00 thru-holes. *At.0mL/min incoming flow rate with room temperature water. Prime/Purge Valve Micro Splitter Valve formation: ternal Max. Volume Operating (closed/ Pressure Min. Split Valve Type Threads fully open) (psi/bar) Flow Rate P-50 /-8. /. µl µl/min P /.8 µl µl/min P-5 Medium Pres. Capillary 0- / 6-. /. µl µl/min P-60S,T High Pressure 0-. /.8 µl,000 / 76.8µL/min P-70 High Pres. Graduated 0-. /.8 µl,000 / 76.8µL/min M-05S,T High Pres. Capillary 0- / 6-. /. µl,000 / 76.8µL/min M-7 High Pres. Cap. Grad. 0- / 6-. /. µl,000 / 76.8µL/min The supply and waste port thru-holes have IDs of.00. The ID for the split-stream port thruhole is.00 in standard versions; in capillary versions it is.00. All tests conducted at an incoming flow rate of ml/min. using room temperature water, with equal pressures on both effluent streams. Lower incoming flow rates will result in a gradual loss of sensitivity when setting the split rate. Air within the pump head can cause noisy pump operation and flow instability. Solve this problem by placing a High Pressure Micro-Splitter Valve or High Pressure Universal Prime/Purge Valve (page 06) inline between the pump and the injector valve. You can then safely divert pump flow to a waste container at a sufficient rate to dislodge the air. Remove air from the solvent line leading to the pump with a Low Pressure Prime/Purge Valve (page 06). Multi- and Systems M-05S High Pressure Capillary, 0-/6-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing and () F-5 PEEK Micro Fingertight for capillary tubing * M-05T High Pressure Capillary, 0-/6-, with titanium needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing and () F-5 PEEK Micro Fingertight for capillary tubing* P-50, /-8, biocompatible cludes: () P-00 Tefzel (ETFE) Ferrules and () P-5 PEEK Flangeless Nuts for /6 OD tubing P-5, 0-, biocompatible cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing P-5 Capillary, 0-/6-, biocompatible cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing () F-5 PEEK Micro Fingertight for capillary tubing* P-60S High Pressure, 0-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing P-60T High Pressure, 0-, with titanium needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing OUT.7 Does your work require analyses with multiple columns and detectors that use the same mobile phase? If so, install one of our High Pressure after your injector. A single injection can then be split to two separate columns and detector systems, at two different flow rates. This economical set-up eliminates the need for an additional pump and injector valve, while allowing data to be obtained simultaneously. Post- terfacing.0. Flow Rates as Low as.5µl/min* /-8 and 0- Designs Available PEEK Polymer Construction, with DuPont Teflon Brand Resin Seals Use a Micro-Splitter Valve to route fluid exiting an initial detector to other devices, such as a mass spectrometer and a fraction collector. The valve will split and reduce the flow rate to that required for MS interfacing, while diverting the remainder of the flow to the collector (a back pressure regulator may also be required for this set up, available on pages 08 0). Order Tel: / P-70 High Pressure Graduated, 0-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing M-7 High Pressure Capillary Graduated, 0-/6-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing and () F-5 PEEK Micro Fingertight for capillary tubing* * Use with our MicroTight Tubing Sleeves, found on page 8. IN.9 Thumbscrew.8 P-5 /-8 threaded PEEK Micro-Metering Valve Other Applications See a flow diagram on page 7 of sample purification and concentration that includes use of a Micro-Splitter Valve. These valves are also suited for other applications, such as adapting a standard HPLC system to handle microbore analyses. For more information and plumbing diagrams for this application and those listed above, please request our Flow Control Valve Applications Guide. ternal Material OD Tubing Thru-hole Volume P-5 PEEK, Black / µL P-6 PEEK, Black / µL P-7 PEEK, Black / µL graduated 0 For terfacing LC-MS Systems Adjustable Split Stream Flow Rates Medium and High Pressure Versions Maximum internal volume, with valve fully open. Comes complete with /-8 P-0/P-00 Flangeless Fittings Comes complete with 0- F-0 One-Piece Fingertight Fittings. Comes complete with /-8 P-0/P-00 Flangeless Fittings. Pressure Rating Order Tel: /

8 Micro-Splitter Valve Applications & Notes Upchurch Scientific offers a line of Micro-Splitter Needle Valves designed to accurately split and control a low-flow stream off a single incoming supply. P-70 The biocompatible are perfect for LC-MS and other multidetector systems and fraction collectors. The ideal placement of these valves is on the effluent side of the detector flow cell, at a maximum pressure of. Choose between /-8 and 0- threaded versions. A valve is also available to accommodate applications involving capillary tubing. M-05S The High Pressure are designed to operate under pressures up to,000 psi (76 bar). These products are well suited for running two analytical devices in parallel. The High Pressure Capillary may also be used to adapt an analytical HPLC system to handle microbore applications. P-50 Our Graduated Valves offer many of the benefits and features of our original, plus the ability to adjust and set the split flow to repeatable settings. This allows documentation of settings and the resulting flow rates for easier method development. The graduations also make it easier to employ the valve in a system used to run multiple analyses that require different split flow rates. Choose from regular High Pressure and Capillary versions. All have been tested at flow rates to 00mL/min., with a maximum resulting pressure drop of only 5 psi (. bar). his valve has a MicroTight 6- threaded fitting on the split stream. Select the appropriately sized T MicroTight Tubing Sleeve from page 8 to connect your capillary tubing. Preasure drop measured when valves fully opened. P-5 Micro-Splitter Valve Thumbscrew Back Pressure Considerations Our are designed to work when both effluent flow path pressures are nearly identical. However, the split flow path will often have higher back pressure than the waste flow path, making it hard to achieve any split flow at all. There are two possible solutions. Place a back pressure regulator (see pages 08 0) on the waste flow path that is equal to or slightly greater than the pressure on the split flow path. Or, switch the two effluent pathways such that the split flow pathway is attached to the waste port on the valve and the waste flow pathway is attached to the split port on the valve. This second method may result in a loss of adjustment sensitivity. For fine control of fluid flow rates, our Micro-Metering Needle Valves can reduce outgoing flow to as low as.5µl/min*. These needle valves are perfect for use with peristaltic pump fluid-transfer applications, mass spectrometry, and fraction collection. Upchurch Scientific can also be used to regulate gas flow in helium sparging lines and as a flow-dependent variable back pressure regulator. For flow independent regulation of back pressure, please see pages Please request our Flow Control Valve Applications Guide for more details. Flow path materials are PEEK polymer and Teflon (O-rings). All versions of this valve have.00 thru-holes. *At.0mL/min incoming flow rate with room temperature water. Prime/Purge Valve Micro Splitter Valve formation: ternal Max. Volume Operating (closed/ Pressure Min. Split Valve Type Threads fully open) (psi/bar) Flow Rate P-50 /-8. /. µl µl/min P /.8 µl µl/min P-5 Medium Pres. Capillary 0- / 6-. /. µl µl/min P-60S,T High Pressure 0-. /.8 µl,000 / 76.8µL/min P-70 High Pres. Graduated 0-. /.8 µl,000 / 76.8µL/min M-05S,T High Pres. Capillary 0- / 6-. /. µl,000 / 76.8µL/min M-7 High Pres. Cap. Grad. 0- / 6-. /. µl,000 / 76.8µL/min The supply and waste port thru-holes have IDs of.00. The ID for the split-stream port thruhole is.00 in standard versions; in capillary versions it is.00. All tests conducted at an incoming flow rate of ml/min. using room temperature water, with equal pressures on both effluent streams. Lower incoming flow rates will result in a gradual loss of sensitivity when setting the split rate. Air within the pump head can cause noisy pump operation and flow instability. Solve this problem by placing a High Pressure Micro-Splitter Valve or High Pressure Universal Prime/Purge Valve (page 06) inline between the pump and the injector valve. You can then safely divert pump flow to a waste container at a sufficient rate to dislodge the air. Remove air from the solvent line leading to the pump with a Low Pressure Prime/Purge Valve (page 06). Multi- and Systems M-05S High Pressure Capillary, 0-/6-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing and () F-5 PEEK Micro Fingertight for capillary tubing * M-05T High Pressure Capillary, 0-/6-, with titanium needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing and () F-5 PEEK Micro Fingertight for capillary tubing* P-50, /-8, biocompatible cludes: () P-00 Tefzel (ETFE) Ferrules and () P-5 PEEK Flangeless Nuts for /6 OD tubing P-5, 0-, biocompatible cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing P-5 Capillary, 0-/6-, biocompatible cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing () F-5 PEEK Micro Fingertight for capillary tubing* P-60S High Pressure, 0-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing P-60T High Pressure, 0-, with titanium needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing OUT.7 Does your work require analyses with multiple columns and detectors that use the same mobile phase? If so, install one of our High Pressure after your injector. A single injection can then be split to two separate columns and detector systems, at two different flow rates. This economical set-up eliminates the need for an additional pump and injector valve, while allowing data to be obtained simultaneously. Post- terfacing.0. Flow Rates as Low as.5µl/min* /-8 and 0- Designs Available PEEK Polymer Construction, with DuPont Teflon Brand Resin Seals Use a Micro-Splitter Valve to route fluid exiting an initial detector to other devices, such as a mass spectrometer and a fraction collector. The valve will split and reduce the flow rate to that required for MS interfacing, while diverting the remainder of the flow to the collector (a back pressure regulator may also be required for this set up, available on pages 08 0). Order Tel: / P-70 High Pressure Graduated, 0-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing M-7 High Pressure Capillary Graduated, 0-/6-, with stainless steel needle cludes: () F-0 PEEK Fingertight Fittings for /6 OD tubing and () F-5 PEEK Micro Fingertight for capillary tubing* * Use with our MicroTight Tubing Sleeves, found on page 8. IN.9 Thumbscrew.8 P-5 /-8 threaded PEEK Micro-Metering Valve Other Applications See a flow diagram on page 7 of sample purification and concentration that includes use of a Micro-Splitter Valve. These valves are also suited for other applications, such as adapting a standard HPLC system to handle microbore analyses. For more information and plumbing diagrams for this application and those listed above, please request our Flow Control Valve Applications Guide. ternal Material OD Tubing Thru-hole Volume P-5 PEEK, Black / µL P-6 PEEK, Black / µL P-7 PEEK, Black / µL graduated 0 For terfacing LC-MS Systems Adjustable Split Stream Flow Rates Medium and High Pressure Versions Maximum internal volume, with valve fully open. Comes complete with /-8 P-0/P-00 Flangeless Fittings Comes complete with 0- F-0 One-Piece Fingertight Fittings. Comes complete with /-8 P-0/P-00 Flangeless Fittings. Pressure Rating Order Tel: /

9 Prime/Purge Valves Prime/Purge Valve for Waters Pumps Automatic Valve Operation with a Simple Twist of a Luer Lock Syringe No Tubing to Cut or Ferrules to Swage No Wear on the ternal Seal The Upchurch Scientific Prime/Purge Valve for Waters pumps automatically opens when a luer syringe is attached and closes when the syringe is removed. No valve rotation is required after the initial installation, so wear on the internal seal is eliminated. addition, our Waters-compatible Prime/Purge Valve is simpler to operate and more economically priced than alternative valves available for Waters systems. This valve is constructed of rugged materials, including a PEEK valve body. The component structure ensures compatibility with virtually all common solvents used in HPLC analyses. A Waters-compatible internal DuPont Teflon brand resin seal is included with the valve. This seal can also be purchased separately. It can be used both with the Upchurch Scientific valve and the original valve supplied with the pump. Attaching Removing the syringe Automatically Opens and Closes the Valve: Syringe (not included) Universal Prime/Purge Valves For Any Style HPLC System Automatic Luer Syringe Operation Featuring Handy Mounting Holes Upchurch Scientific Universal Prime/Purge Valves are easy to operate. Simply install a valve along the flow path with the included fittings and attach a luer-tipped syringe. Then, withdraw the plunger and watch as solvent and residual bubbles are removed from the solvent line. The valves automatically close when the syringe is removed. The low pressure version of the valve is designed to be used with /8 OD tubing, while the high pressure version accommodates /6 OD tubing. Optional mounting is made easy by the handy holes in the body of each unit. Air in the let Solvent Line stall the Low Pressure Universal Prime/Purge Valve along the inlet solvent path near the pump to remove bubbles from the inlet solvent line. The valve can also be used to rapidly wet your solvent inlet filter. When a new filter is installed, it often contains a substantial amount of air within its pores. At standard flow rates, it may require several minutes before the inlet fluid pathway is completely free of gas. Using this valve you are able to rapidly draw solvent through the inlet filter, dislodging the gas and minimizing downtime. Air in the Pumphead Air within the pumphead can cause flow instability and noisy pump operation. Place the High Pressure Prime/Purge Valve between the pump and the sample injector, where it can be used to remove bubbles that have become lodged within your pump. This valve is rated for a maximum pressure of 5,000 psi (5 bar). Luer Port Check Valve Assembly.8.9 V- Low Pressure Universal Prime/Purge Valve Mounting holes are.75 apart 06 The wetted materials for our Waters-compatible and Universal Prime/Purge Valves are ruby, sapphire, PEEK, Teflon and stainless steel. For another luer check valve option, see the Quick-Stop Luer line Check Valve on page. Order Tel: / Prime/Purge Valves V-0 Prime/Purge Valve for Waters Pumps cludes () V-0-06 Teflon seal V-0-06 Replacement Teflon Seal (for V-0) V- Low Pressure Universal Prime/Purge Valve cludes () P-00N Tefzel Ferrules & () P-5 PEEK Nuts, for /8 OD tubing V- High Pressure Universal Prime/Purge Valve cludes () F-0 Fittings for /6 OD tubing B-0 0cc Disposable Luer-Tipped Syringe

10 Prime/Purge Valves Prime/Purge Valve for Waters Pumps Automatic Valve Operation with a Simple Twist of a Luer Lock Syringe No Tubing to Cut or Ferrules to Swage No Wear on the ternal Seal The Upchurch Scientific Prime/Purge Valve for Waters pumps automatically opens when a luer syringe is attached and closes when the syringe is removed. No valve rotation is required after the initial installation, so wear on the internal seal is eliminated. addition, our Waters-compatible Prime/Purge Valve is simpler to operate and more economically priced than alternative valves available for Waters systems. This valve is constructed of rugged materials, including a PEEK valve body. The component structure ensures compatibility with virtually all common solvents used in HPLC analyses. A Waters-compatible internal DuPont Teflon brand resin seal is included with the valve. This seal can also be purchased separately. It can be used both with the Upchurch Scientific valve and the original valve supplied with the pump. Attaching Removing the syringe Automatically Opens and Closes the Valve: Syringe (not included) Universal Prime/Purge Valves For Any Style HPLC System Automatic Luer Syringe Operation Featuring Handy Mounting Holes Upchurch Scientific Universal Prime/Purge Valves are easy to operate. Simply install a valve along the flow path with the included fittings and attach a luer-tipped syringe. Then, withdraw the plunger and watch as solvent and residual bubbles are removed from the solvent line. The valves automatically close when the syringe is removed. The low pressure version of the valve is designed to be used with /8 OD tubing, while the high pressure version accommodates /6 OD tubing. Optional mounting is made easy by the handy holes in the body of each unit. Air in the let Solvent Line stall the Low Pressure Universal Prime/Purge Valve along the inlet solvent path near the pump to remove bubbles from the inlet solvent line. The valve can also be used to rapidly wet your solvent inlet filter. When a new filter is installed, it often contains a substantial amount of air within its pores. At standard flow rates, it may require several minutes before the inlet fluid pathway is completely free of gas. Using this valve you are able to rapidly draw solvent through the inlet filter, dislodging the gas and minimizing downtime. Air in the Pumphead Air within the pumphead can cause flow instability and noisy pump operation. Place the High Pressure Prime/Purge Valve between the pump and the sample injector, where it can be used to remove bubbles that have become lodged within your pump. This valve is rated for a maximum pressure of 5,000 psi (5 bar). Luer Port Check Valve Assembly.8.9 V- Low Pressure Universal Prime/Purge Valve Mounting holes are.75 apart 06 The wetted materials for our Waters-compatible and Universal Prime/Purge Valves are ruby, sapphire, PEEK, Teflon and stainless steel. For another luer check valve option, see the Quick-Stop Luer line Check Valve on page. Order Tel: / Prime/Purge Valves V-0 Prime/Purge Valve for Waters Pumps cludes () V-0-06 Teflon seal V-0-06 Replacement Teflon Seal (for V-0) V- Low Pressure Universal Prime/Purge Valve cludes () P-00N Tefzel Ferrules & () P-5 PEEK Nuts, for /8 OD tubing V- High Pressure Universal Prime/Purge Valve cludes () F-0 Fittings for /6 OD tubing B-0 0cc Disposable Luer-Tipped Syringe

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New! Inlet Solvent Filters Filters and Degassers General Use Inlet Solvent Filters Large Surface Areas disposable µm, 0 µm, and 0 µm Pore Sizes Available General Use and Prep Filters for Higher Flow Applications

More information

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter HPLC ACCESSORIES IDEX Injection Valves IDEX Injection Valves Manual IDEX MANUAL INJECTION VALVES DESCRIPTION POS. SENSING SWITCH MAX PSI FITTING HIGH PRESSURE, ANALYTICAL (accepts a 22 gauge needle) FITS

More information

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO 8 SupelPRO Valves Order:.800..00 Technical Service:.800.9.0 Web: www.sigma-aldrich.com/supelco SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled,

More information

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 156 Inlet Solvent

More information

Upchurch High Pressure Fittings & Connectors

Upchurch High Pressure Fittings & Connectors .010 thru-hole P-742 PEEK ZDV Union. 9 2.050 thru-hole P-760 PEEK ZDV Union P-704 PEEK ZDV Union. 9 2. 9 2 Fingertight Fittings ONE-PIECE FINGERTIGHT FITTINGS INTRODUCTION For Coned Ports For convenience

More information

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching High Pressure Valves MX Series II Modules Manual Sample Injection Introduction to High Pressure Valves HIGH Pressure Valves High Pressure Valves Introduction Rheodyne valves fit virtually any flow control

More information

Ultra High Performance Fittings. Fittings Connectors Kits

Ultra High Performance Fittings. Fittings Connectors Kits Ultra High Performance Fittings Fittings Connectors Kits Ultra High Performance Fittings Introduction Ultra Performance Fittings Introduction high Temperature Versions Withstand Temperatures up to 200ºC

More information

IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 Filters & Frits Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

More information

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings. Fingertight Fittings 4 One-Piece Fingertight Fittings Upchurch Scientific s original One-Piece Fingertight Fittings have 0-3 threads and are designed to be used with /6 OD tubing, except the M-645 (6-40,

More information

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271 Restek Replacement Parts for Agilent HPLC Systems Meet or exceed OEM performance. Agilent part # qty. cat.# price Preventive Maintenance Kit Includes: rotor seal, needle seat, needle assembly, seat cap

More information

QuickSplit TM Flow Splitters

QuickSplit TM Flow Splitters Quick TM Flow ters Quick TM Flow ter Features: Fluid resistor technology eliminates tedious adjustments to capillary tubing for split ratio optimization ratios are stable and reproducible, and not affected

More information

78 동방하이테크상사 T.(02) F.(02)

78 동방하이테크상사  T.(02) F.(02) 78 동방하이테크상사 http://www.allpump.co.kr T.(0)7-9 F.(0)7-9 00--7 Introduction to Introduction Rheodyne valves fit virtually any high-pressure flow control application. As you ll see from the table below and

More information

PrimeLine TM HPLC Pumps

PrimeLine TM HPLC Pumps PrimeLine TM HPLC Pumps Isocratic Model 501 Gradient System 500G PrimeLine TM Isocratic and Gradient HPLC Pumps Feature: Self-priming pump head requires no manual priming Patented Floating Pump Seal design

More information

FITTINGS, LOOPS, AND VALVE ACCESSORIES

FITTINGS, LOOPS, AND VALVE ACCESSORIES FITTINGS, LOOPS, AND VALVE ACCESSORIES Fittings Rheodyne offers a variety of fittings. They differ in material of construction, tubing size, and pressure rating. Materials/Biocompatibility. 316 stainless

More information

VERITY Purification Systems Build the perfect system to fit your research

VERITY Purification Systems Build the perfect system to fit your research VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC

More information

(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 .

(pages 58 and 59) Nuts .48. Standard XP-201 XP-206 XP-220 XP-230 XP-238 XP-245 XP-245B XP-301 XP Headless XP-286 XP-386. Ferrules .22 . Low Pressure FITTINGS & CONNECTORS Dimensions for /4-8 Upchurch Scientific eliminate the need to flange. This removable and reusable system provides several benefits: (pages 58 and 59) Convenience: Our

More information

HIGH PRESSURE SWITCHING VALVES

HIGH PRESSURE SWITCHING VALVES HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available

More information

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS Deburring an Upchurch Scientific fitting in Oak Harbor, WA. The Very High Pressure (VHP) reusable fitting, VHP-320, is one of the exciting new products in the

More information

Instrument Accessories & Parts, Tubing & Connections

Instrument Accessories & Parts, Tubing & Connections Instrument Accessories & Parts, Tubing & Connections ASI Piston Seals for Agilent HPLC Systems Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed

More information

FILTERS & COLUMN ACCESSORIES

FILTERS & COLUMN ACCESSORIES 156 FILTERS & COLUMN ACCESSORIES INLET SOLVENT FILTERS PAGE 157 INLINE SOLVENT FILTERS PAGE 160 PRECOLUMN FILTERS PAGE 163 FRITS PAGE 165 GUARD COLUMNS PAGE 170 SEE STARRED PRODUCTS FOR TOP SELLERS! Inlet

More information

Fixed Flow Splitter *

Fixed Flow Splitter * Fixed Flow * *Patent Pending Analytical Scientific Instruments Fluid resistor technology eliminates tedious adjustments to capillary tubing to change split ratios. Easy to use interchangeable fluid resistors

More information

Polymeric Fittings Low Pressure

Polymeric Fittings Low Pressure INDEX PPS Nuts for Flat Bottom Fitting Details 59 PEEK Flangeless Nuts 62 Polyacetal Color Coded Flangeless Nuts 63 Polypropylene Flanged Fingertight Nuts 64 Unions 65 Bulkhead Unions 67 PEEK Tees, Crosses

More information

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage. 1. Overview The front panel houses the UV detector lamp switch, Rheodyne injection valve, prime/purge valve, pressure gauge, and the storage compartment. In the storage compartment are the LED display

More information

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching High Pressure Valves MX Series II Modules Manual Sample Injection Switching Introduction to High Pressure Valves HIGH PRESSURE VALVES High Pressure Valves Introduction Rheodyne valves fit virtually any

More information

Adjustable Flow Splitter *

Adjustable Flow Splitter * Adjustable Flow Splitter * *Patent Pending Analytical Scientific Instruments Adjustable metering valve enables precise direct control over split ratios. Fluid resisr technology eliminates tedious adjustments

More information

VALVES NEW MANUAL INJECTOR RHEBUILD KITS SAMPLE LOOPS MICRO VALVES PAGE 132 PAGE 136 PAGE 139 PAGE

VALVES NEW MANUAL INJECTOR RHEBUILD KITS SAMPLE LOOPS MICRO VALVES PAGE 132 PAGE 136 PAGE 139 PAGE VALVES NEW MANUAL INJECTOR PAGE RHEBUILD KITS PAGE 6 SAMPLE LOOPS PAGE 9 MICRO VALVES PAGE 6 SEE STARRED PRODUCTS FOR TOP SELLERS! Valve Overview VALVES 5 Rotary Shear Valves Rheodyne Rotary Shear Valves

More information

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bio science ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector

More information

Agilent SD-1 Purification System ml/min

Agilent SD-1 Purification System ml/min Agilent SD-1 Purification System - 200 ml/min Introduction Installation of the Capillary Kit This technical note shows you how to install the Stainless Steel Capillary Kit (SD- 1 Purification System -

More information

Quick Reference Guide. Supplies for Waters HPLC Systems

Quick Reference Guide. Supplies for Waters HPLC Systems Quick Reference Guide Supplies for Waters HPLC Systems works with WATERS SHIMADZU THERMO/DIONEX BRUKER/VARIAN PERKINELMER CTC MORE Put innovation and quality to work on a wide range of GCs and HPLCs in

More information

S 1125 HPLC Pump System

S 1125 HPLC Pump System Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make

More information

Agilent 218 Purification Solution

Agilent 218 Purification Solution Agilent 218 Purification Solution System User Guide Purification Solution System User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2012, 2013 No part of this manual may be reproduced in

More information

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C C OMPONENT S F O R A C L O S E D - S YS T E M HPL C TM Western Analytical Products, Inc hplc and gc columns and accessories fittings, tubing, valves, frits and filters lab and industrial safety products

More information

Agilent 210/218 - Isocratic Pump

Agilent 210/218 - Isocratic Pump Agilent 210/218 - Isocratic Pump Installation of the Stainless Steel Tubing Kit Introduction This technical note shows you how to install the Stainless Steel Tubing Kit for the isocratic pump of the Agilent

More information

Mobile Phase Accessories

Mobile Phase Accessories NEW! Now available for GL-45 bottles! Bottles not included Waste Overflow Indicator Avoid messy pooling around mobile phase waste containers. Audible alarm instantly alerts user, preventing overflow. Compact,

More information

FLUIDICS FITTINGS. 32 CONED FITTINGS 39 FLAT-BOTTOM FITTINGS 48 MarvelX 50 FITTINGS TOOLS 56 LARGE BORE FITTINGS 57 VHP FITTINGS 61 FITTINGS KITS

FLUIDICS FITTINGS. 32 CONED FITTINGS 39 FLAT-BOTTOM FITTINGS 48 MarvelX 50 FITTINGS TOOLS 56 LARGE BORE FITTINGS 57 VHP FITTINGS 61 FITTINGS KITS 30 FITTINGS We offer a wide and diverse selection of fittings to meet your system requirements. A fitting refers to a complete product ready to assemble and connect tubing into a part. This could be a

More information

Agilent G5632 Valve Kit Instructions

Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Agilent G5632 Valve Kit Instructions Contents Typical Applications 2 Alternating Column Regeneration (2 position/10 port valves only) 2 Dual column selection 3 Sample

More information

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913 GLENCO Syringes As a complement to the Spectra/Chrom chromatographic products, Spectrum manufactures precision syringes for sample injection and collection. These syringes are designed specifically to

More information

HPLC Tubing and Fittings Hints & Tips for the Chromatographer

HPLC Tubing and Fittings Hints & Tips for the Chromatographer HPLC Tubing and Fittings Hints & Tips for the Chromatographer By William S. Letter (Chiralizer Services, L.L.C.) INTRODUCTION: Setting up a high pressure liquid chromatography (HPLC) system to run trouble-free

More information

Miniature Multimedia Valves

Miniature Multimedia Valves 2 Inert Isolation PTFE 3-Way Solenoid Valve Series 1 The Series 1 diaphragm type valve has a low internal volume and rapid response time, which enables users to get readings quickly for their analysis.

More information

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers HyperShear TM HPLC and UHPLC s Reduce baseline noise, increase sensitivity and improve gradient accuracy Decrease mixing and delay volume without sacrificing mixing efficiency Increase reaction efficiency

More information

Valving Schemes for the BioLogic Duo-Flow Chromatography System

Valving Schemes for the BioLogic Duo-Flow Chromatography System Valving Schemes for the iologic Duo-Flow Chromatography System table of contents pplication asic ion Valve Operation using,, and Purge Positions position is for filling a loop with sample or for running

More information

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION Waters Advanced Purification (AP) series of glass columns are constructed of biocompatible glass and polymeric materials and can be easily used with

More information

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent Valve Kit G4231A/B and G4232A/B/C Agilent Valve Kit G4231A/B and G4232A/B/C Instructions Contents Typical Applications 2 Dual column selection (G4231A/B or G4232A/B/C) 2 Sample enrichment and sample cleanup (G4231A/B or G4232A/B/C) 2 Alternating

More information

819 Injection Module User s Guide

819 Injection Module User s Guide 819 Injection Module User s Guide LT2533/ 2004 Gilson, Inc. All rights reserved August 2004 Table of Contents Declaration of Conformity 1 Introduction 2 Installation 3 Operation 4 Maintenance Unpacking...

More information

ÄKTA system Training Guide

ÄKTA system Training Guide ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector

More information

HyperShear TM HPLC Mixers

HyperShear TM HPLC Mixers HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex sheer mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume

More information

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations. Simplify your search for COLUMN HARDWARE Discover how to maximize results with Isolation Technologies column hardware and accessories that are specifically engineered to meet critical UHPLC, HPLC, and

More information

Liquid Chromatography LC Consumables SSI-LC

Liquid Chromatography LC Consumables SSI-LC Liquid Chromatography LC Consumables SSI-LC-10-2017 Table of Contents HPLC Pumps...3 LC-30AD... 3 LC-20AD / LC-20AB / LC-20ADXR... 4 LC-20AT... 4 LC-20Ai... 5 LC-10ADvp... 5 LC-10ATvp... 6 LC-10Ai... 6

More information

High Pressure Gradient System. User Manual. Version 1.0 ( )

High Pressure Gradient System. User Manual. Version 1.0 ( ) S 9432 HPLC Pump System High Pressure Gradient System User Manual Version 1.0 (2014-05-26) 2 Table of Contents Contents 1. Introduction 5 1.1 How to Use this Manual 5 1.1.1 Symbols 5 1.2 Safety Information

More information

QuickSplit TM Adjustable Flow Splitters Analytical Splitters Analytical range, 0.1 ml/min. to 5 ml/min. input flow, calibration flow rate 1.0 ml/min.

QuickSplit TM Adjustable Flow Splitters Analytical Splitters Analytical range, 0.1 ml/min. to 5 ml/min. input flow, calibration flow rate 1.0 ml/min. Adjustable Flow ters Applications Post-column splitting is fairly straight forward. Like pre-column flow splitting, any significant additional pressure (resistance) down stream from the splitter may affect

More information

CONNECTORS VHP UNIONS LOW PRESSURE UNIONS THREADED ADAPTERS BARBED ADAPTERS PAGE 36 PAGE 40 PAGE 48 PAGE 58.

CONNECTORS VHP UNIONS LOW PRESSURE UNIONS THREADED ADAPTERS BARBED ADAPTERS PAGE 36 PAGE 40 PAGE 48 PAGE 58. 34 CONNECTORS VHP UNIONS PAGE 36 LOW PRESSURE UNIONS PAGE 40 THREADED ADAPTERS PAGE 48 BARBED ADAPTERS PAGE 58 SEE STARRED PRODUCTS FOR TOP SELLERS! i INTRODUCTION How to Order How to Order Direct from

More information

Agilent 210/218 - Binary Pump

Agilent 210/218 - Binary Pump Agilent 210/218 - Binary Pump Installation of the Stainless Steel Tubing Kit Introduction This technical note shows you how to install the Stainless Steel Tubing Kit for the binary pump of the Agilent

More information

CHROMATOGRAPHY. SYKAM S 6000 Valve Series

CHROMATOGRAPHY. SYKAM S 6000 Valve Series CHROMATOGRAPHY SYKAM S 6000 Valve Series Version: March 2011 SYKAM S 6000 Valve Series Rotor Seals Sykam offers a variety of different Rotor Seals materials to satisfy any possible application. All materials

More information

HPLC SYSTEM S 500 SERIES

HPLC SYSTEM S 500 SERIES HPLC SYSTEM S 500 SERIES The Sykam HPLC System S 500 Series is intended for all routine analysis as well as for the ambitious analyst. The system configuration is highly variable and several upgrade options

More information

1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION

1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION 1Valcor Scientific Subminiature Teflon Valve 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS Model SV20-1 is suitable for a broad range of light industrial applications, both new and retrofit.

More information

Maintaining Your Agilent 1100 Series HPLC System

Maintaining Your Agilent 1100 Series HPLC System Operate your lab at peak performance Troubleshoot difficult problems Select the right Agilent supplies For detailed information about supplies from Agilent, please contact your local Agilent sales representative,

More information

HyperShear TM HPLC Mixers

HyperShear TM HPLC Mixers HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex shear mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume

More information

Solvent Safety Bottle Caps

Solvent Safety Bottle Caps Solvent Safety Bottle Caps 2 Index Page 4 Page 6 Q-SERIES BOTTLE CAPS 1/4-28 UNF ports with optional on-off valves. A screw-in check valve and filter is available for a completely closed solvent supply

More information

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL 1993 Dionex Corporation Document No. 034859 Revision 02 September 1993 1993 Dionex Corporation All rights reserved worldwide Printed in the United States

More information

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test GlycoChrom TM HPLC Analyzer Hardware Installation and System Test PIN 410-5004 For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-8 00-424-6723) ,, Table of Contents

More information

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers HyperShear TM HPLC and UHPLC s HyperShear TM HPLC and UHPLC Features: Micro Flow, Low Flow, Analytical Flow, High Flow and Combo Series Reduce baseline noise, increase sensitivity and improve gradient

More information

This convenient system is made entirely of inert parts: glass, Baseline drift

This convenient system is made entirely of inert parts: glass, Baseline drift 95 P000515 55020 9960342 Supelco Mobile Phase Degassing System 55060-U Eliminates: Flow instabilities Mobile Phase Reservoir System Detector noise This convenient system is made entirely of inert parts:

More information

GENERAL CATALOG L.TEX CORPORATON

GENERAL CATALOG L.TEX CORPORATON GENERAL CATALOG L.TEX CORPORATON 1/8 동방하이테크상사 http://www.allpump.co.kr T.(02)457-6292 F.(02)457-6293 13-12-01 L. Tex Corporation was established in March 2001 to design, develop and manufacture the versatile

More information

KEY FEATURES. Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups

KEY FEATURES. Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups CapTite Microfluidic Construction Kits KEY FEATURES Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups Routing fluids can be one of

More information

Mobile Phase Management

Mobile Phase Management hplc columns & accessories hplc accessories Mobile Phase Management The solvent filtration apparatus rapidly filters and degasses HPLC and IC mobile phases. Description Part No. 1L Flask, 300mL Funnel,

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Agilent Valve Kit G4231A/B/C and G4232B/C/D Agilent Valve Kit G4231A/B/C and G4232B/C/D Instructions Agilent Valve Kit G4231A/B/C and G4232B/C/D - Instructions This Technical Note describes the installation of the Agilent G4231A/B/C and G4232B/C/D

More information

HPLC System S 600 Series

HPLC System S 600 Series HPLC System S 600 Series The Sykam HPLC System S 600 Series is intended for the ambitious analyst. The system configuration is highly variable and several upgrade options make this system suitable for

More information

Flow System Accessories

Flow System Accessories Flow System Accessories Fitting Systems MicruX is able to provide different accessories, from several suppliers, usually required for using the standard thinfilm (micro)electrodes in flowing liquids systems.»

More information

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer Technical Note This Technical Note describes the installation of the G9324A Delay Coil Organizer to an Agilent Infinity II system. Contents

More information

MODEL 905V OPERATING INSTRUCTIONS

MODEL 905V OPERATING INSTRUCTIONS MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions

More information

Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors

Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors Inlet / Waste Tubings Replacement This technical note describes the installation of the inlet/waste tubing kit to a 1260 Infinity II Fraction

More information

CTC Analytics Service Note June 2015 PAL-xt: Material change for Rotor Seal of C2V-3006-CTC

CTC Analytics Service Note June 2015 PAL-xt: Material change for Rotor Seal of C2V-3006-CTC To: Dealer/OEM orld-ide, PAL Systems Platform PAL and PAL-xt Systems From: Toni Eberwein Date: June 19, 2015 Subject: change for rotor seal C2-30R (for valve C2V-300D-CTC) CTC Alytics Service Note June

More information

Agilent 1200 Series Valves

Agilent 1200 Series Valves Agilent 1200 Series Valves User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

ReciPro Liquid Metering Pumps. Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options

ReciPro Liquid Metering Pumps. Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options ReciPro Liquid Metering Pumps Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options ReciPro HP Series Eldex metering pumps can be used wherever precise flow rate

More information

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Extended range HPLC has been investigated for many years; however, progress was delayed because of

More information

Liquid Chromatography

Liquid Chromatography SCINTOMICS Liquid Chromatography Always the right system for your needs. SCINTOMICS: Always the right system for your needs Advanced Research Daily QC Routine and beyond High Performance analytical/semi-preparative

More information

PICO Pµlse Contact Dispense Valve

PICO Pµlse Contact Dispense Valve PICO Pµlse Contact Dispense Valve The Latest Advance in Precision Contact Dispensing Technology The PICO Pµlse contact dispense valve delivers faster, more precise dispensing with less turbulence for greater

More information

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like

More information

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters ADAPTERS Whether converting joint types, reducing or enlarging joints, or creating connections in a distillation apparatus, Kimble offers a comprehensive selection of adapters including bushing adapters,

More information

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Technical Note This Technical Note describes the purpose, installation, and configuration and use of a diverter valve

More information

Graco PD44. Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing

Graco PD44. Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing Graco PD44 Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing Graco PD44 Valve for Precise Micro-Dispensing 1.0cc 0.50cc 0.25cc 0.1cc 0.005cc 1/16" Dia. 1/8" Dia. 3/16" Dia. 1/4"

More information

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,

More information

ACQUITY UPLC I-Class System with 2D Technology

ACQUITY UPLC I-Class System with 2D Technology ACQUITY UPLC I-Class System with 2D Technology The Waters ACQUITY UPLC I-Class System with 2D Technology allows chemists to increase sensitivity and selectivity, eliminate unwanted interferences, characterize

More information

Universal Pipette Tips Ultra-clear and certified RNase/DNase-free

Universal Pipette Tips Ultra-clear and certified RNase/DNase-free Universal Pipette Tips Ultra-clear and certified RNase/DNase-free Universal Tips Tip Volume For Pipetter Bulk Rack 0.1-10 μl 5 - μl 0 0 Bag of 1000 500191 US$15 960 (10 racks of 96) 500192 US$30 Bag of

More information

Heated Perfusion Cube

Heated Perfusion Cube Heated Perfusion Cube HPC-2 / HPC-2A Instruction Manual ver. Feb.2011 ALA Scientific Instruments Inc. 60 Marine Street Farmingdale, NY 11735 Tel. # 631.393.6401 FAX: # 631.393.6407 E-mail: support@alascience.com

More information

Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art

Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art BETTER SAMPLE CARE Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art autosampler for ÄKTA pure Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art autosampler

More information

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE gilent InfinityLab LC urification Solutions SELECTION GUIDE GILENT INFINITYLB LC URIFICTION SOLUTIONS EFFICIENT LC URIFICTION SOLUTIONS FOR NLYTICL TO RERTIVE SCLE gilent InfinityLab LC urification Solutions

More information

Kontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos Four Valve Filtration / Delivery Caps

Kontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos Four Valve Filtration / Delivery Caps Kontes Brand ULTRA-WARE Five Valve Recirculation / Filtration Caps Kontes Article Nos. 953983-0047 953983-6347 Four Valve Filtration / Delivery Caps Kontes Article Nos. 953981-0047 953981-6347 Filter Size:

More information

DETECTORS Photo Ionization Detector - PID. Overview

DETECTORS Photo Ionization Detector - PID. Overview Overview DETECTORS The Photo Ionization Detector (PID) responds to all molecules whose ionization potential is below 10.6eV, including aromatics and molecules with carbon double bonds. The PID is nondestructive,

More information

GE Healthcare. Valve INV-917. Instructions

GE Healthcare. Valve INV-917. Instructions GE Healthcare Valve INV-917 Instructions INV-917 2 1 3 7 4 5 6 Important user information All users must read this entire manual to fully understand the safe use of Valve INV-917. Important! Valve INV-917

More information

Instrumentation of HPLC. HPLC Solvent Pumping Systems

Instrumentation of HPLC. HPLC Solvent Pumping Systems Instrumentation of HPLC HPLC Solvent Pumping Systems i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference

More information

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,

More information

PICO Pµlse Jet Valve System

PICO Pµlse Jet Valve System PICO Pµlse Jet Valve System The Latest Advance in Precision Jetting Technology The PICO Pµlse non-contact jet valve delivers faster, more precise dispensing over smooth and uneven surfaces with less turbulence

More information

NEW HPLC - SYSTEM LINE

NEW HPLC - SYSTEM LINE NEW HPLC - SYSTEM LINE S c h a m b e c k S F D G m b H Drieschweg 13A D-53604 Bad Honnef/Germany Phone: +49 2224 9239-0 E-Mail: info@schambeck-sfd.com Internet: www.schambeck-sfd.com S 9425 HPLC solvent

More information

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems HPLC Essentials Genuine Replacement Parts for HPLC Systems 20 YEARS Turning Visions into Reality 800-356-1688 814-353-1300 2 Becky Wittrig HPLC Products Marketing Manager 4+ years of service! did you know?

More information

LC Instrument Replacement Parts

LC Instrument Replacement Parts LC Instrument Replacement Parts /SSI Parts /SSI Pump Replacement Parts Alltech Pump Replacement Parts Misc. Pump Supplies Agilent Parts & Supplies for Agilent Instrumentation 1260 Infinity Isocratic LC

More information

The PMAC Dynamic Scale Loop

The PMAC Dynamic Scale Loop The Dynamic Scale Loop Original System for evaluation of scaling tendency and inhibitor performance The System is an invaluable research and development tool for technologists responsible for the design,

More information

Gradient Pumping for Pressure, Flow, and Concentration Modes

Gradient Pumping for Pressure, Flow, and Concentration Modes Gradient Pumping for Pressure, Flow, and Concentration Modes With Teledyne Isco Syringe Pumps Syringe Pump Technical Bulletin TB24 Overview Gradient pumping is used in applications requiring time-controlled

More information

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment Agilent G1316A Thermostatted Column Compartment Technical Note Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment System Requirements 2 Performance Specifications

More information