Stability Axial Compression Technology Application Ordering Information

Size: px
Start display at page:

Download "Stability Axial Compression Technology Application Ordering Information"

Transcription

1 42 YMC-Actus

2 YMC-Actus 43 YMC-Actus Contents Stability Axial Compression Technology Application Ordering Information Introduction Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC. Even though the chromatographic systems used for semi-preparative LC are not as large as preparative LC systems, the objectives remain the same: Purification and isolation of maximum sample quantity Savings in time and costs. With YMC-Actus, time is on your side! * Application data by courtesy YMC Co., Ltd.

3 44 YMC-Actus YMC-Actus Stability Rapid pressure changes under high-speed gradient conditions may lead to column degradation and loss of column performance. With YMC-Actus, a new hardware and packing technology has been applied to these semipreparative columns to provide a uniform packing density which results in a longer lifetime than conventional semi-preparative columns. In order to determine the quality of the packing, the column performance has been evaluated every 100 runs with a sequential high-throughput gradient. YMC-Actus columns offer outstanding efficiency without compromising resolution. Furthermore, YMC-Actus columns provide reliable results, even after exposure to severe, rapid gradient conditions and multiple injections. Increase column lifetime = Decrease of cost Conventional semi-preparative column Sequential gradient test Colum: 50 x 20 mm ID, 5 µm Eluent: A) water B) methanol Gradient: Flow rate: 50 ml/min Temp.: ambient 5% B (0-0.5 min), 5-95% B ( min), 95% B ( min), 5% B ( min) Column performance test Column: 50 x 20 mm ID, 5 µm Eluent: methanol / water (70/30) Flow rate: 10 ml/min Sample: Naphthalene

4 YMC-Actus 45 YMC-Actus Axial Compression Technology for Ultimate Separation YMC-Actus series columns are semi-preparative HPLC columns that have excellent column stability and efficiency as a result of applying axial compression technology. YMC-Actus series columns show high stability under high flow rate or steep gradient conditions which are desirable for milligram scale preparative HPLC of various compounds. 10% increase in bed density Compressing Flow Test conditions (high-speed and high-pressure) Column: 5 µm, 50 x 20 mm ID Eluent: A) water B) methanol Gradient: 5%-95% B Flow rate: 50 ml/min Pressure: ~ 17 MPa Long Lasting Columns! after 700 runs initial Conventional Column Packing without compression Flow Void and crack Degradation of performance after 300 runs initial Uniformly high density packing is necessary for highly efficient and stable HPLC columns. DAC (Dynamic Axial Compression) columns are widely used for preparative separation in pilot or production scale. This allows uniformly high density packing and prevents formation of voids. YMC-Actus series columns have been developed by applying this Axial Compression Technology to semi-prep column production. The column bed is compressed appropriately when attaching the inlet end assembly of the newly designed YMC-Actus hardware. It provides increased bed density (10% higher than conventional columns) and bed uniformity. * Application data by courtesy YMC Co., Ltd.

5 46 YMC-Actus YMC-Actus Excellent stability and efficiency under fast gradient conditions at high flow rate Glycyrrhizic acid in herb medicine* Analysis Purification Eluent: A) water / acetic acid (99/1) B) methanol / acetic acid (99/1) 20% B (0-2 min), 20-45% B (2-7 min), 45% B (7-10 min) Temperature: ambient Detection: UV at 260 nm Sample: water / methanol / acetic acid extract of commercially available herb medicine (0.1 g/ml) Available for high-throughput purification: Injection in DMSO 1. Ethenzamide 2. Clemastine fumarate 3. Ibuprofen Column: YMC-Actus Pro C18 RS (5 µm, 8 nm), 50 x 20 mm ID Eluent: A) water / TFA (100/0.1) B) acetonitrile / TFA (100/0.1) Gradient: 10-90% B (0-3 min), 90% B (3-5 min), 10% B (5-10 min) Flow rate: 20 ml/min Temperature: ambient Detection: UV at 270 nm Injection: 100 µl (0.2-2 mg/ml in DMSO) As shown in overlay chromatograms, YMC-Actus columns provide outstanding stability and reproducibility in the separation of pharmaceuticals dissolved in 100% DMSO, even after 1,000 injections under the test conditions. This makes YMC-Actus columns ideal for high-throughput purification in drug discovery.

6 YMC-Actus 47 YMC Actus Excellent separation of compounds with similar structure Capsaicinoids in red pepper* Analysis 50 x 4.6 mm ID, 5 µm 2.0 ml/min, 20 µl injection Phenomenex Luna C18 Waters XBridge C18 YMC-Pack Pro C18 RS Purification YMC-Actus Pro C18 RS, 50 x 20 mm ID 5 µm Nordihydrocapsaicin Capsaicin Dihydrocapsaicin 40 ml/min, 400 µl injection Purity >99.5% Eluent: A) methanol / water / TFA (50/50/0.1) B) methanol / TFA (100/0.1) 0-30% B (0-5 min), 30% B (5-10 min) Temperature: 25 C for 50 x 4.6 mm ID ambient for 50 x 20 mm ID Detection: UV at 280 nm Sample: methanol extract of a commercial red pepper (1 g / 3 ml) Outstanding separation of highly polar compounds Crude synthetic 30mer oligonucleotide* Analysis Hydrosphere C ml/min, 5 µl injection Purification 19 ml/min, 100 µl injection 50 x 4.6 mm ID, 5 µm 50 x 20 mm ID, 5 µm Impurities 30mer YMC-Actus Hydrosphere C18 Recovery 56% Eluent: A) 10 mm DBA-acetic acid (ph 6.0) / methanol (60/40) B) 10 mm DBA-acetic acid (ph 6.0) / methanol (20/80) 10-35% B (0-30 min) Temperature: ambient Detection: UV at 269 nm Sample: synthetic oligonucleotide (100 µm) purity>99% * Application data by courtesy YMC Co., Ltd.

7 48 YMC-Actus Ordering Information High durability semi-preparative columns Packing material Particle size [µm] Pore size [nm] Column size length x ID [mm] Product Code Triart C18 S-5 12 Pro C18 S-5 12 Hydrosphere C18 S-5 12 Pro C18 RS S-5 8 Triart C8 S-5 12 Pro C8 S x 20 TA12S WX 100 x 20 TA12S WX 150 x 20 TA12S WX 250 x 20 TA12S WX 50 x 30 TA12S WX 75 x 30 TA12S05-L530WX 100 x 30 TA12S WX 150 x 30 TA12S WX 250 x 30 TA12S WX 100 x 50 TA12S DX 150 x 50 TA12S DX 250 x 50 TA12S DX 50 x 20 AS12S WX 100 x 20 AS12S WX 150 x 20 AS12S WX 250 x 20 AS12S WX 50 x 30 AS12S WX 75 x 30 AS12S05-L530WX 100 x 30 AS12S WX 150 x 30 AS12S WX 250 x 30 AS12S WX 100 x 50 AS12S DX 150 x 50 AS12S DX 250 x 50 AS12S DX 50 x 20 HS12S WX 100 x 20 HS12S WX 150 x 20 HS12S WX 250 x 20 HS12S WX 50 x 30 HS12S WX 75 x 30 HS12S05-L530WX 100 x 30 HS12S WX 150 x 30 HS12S WX 250 x 30 HS12S WX 100 x 50 HS12S DX 150 x 50 HS12S DX 250 x 50 HS12S DX 50 x 20 RS08S WX 100 x 20 RS08S WX 150 x 20 RS08S WX 250 x 20 RS08S WX 50 x 30 RS08S WX 75 x 30 RS08S05-L530WX 100 x 30 RS08S WX 150 x 30 RS08S WX 250 x 30 RS08S WX 100 x 50 RS08S DX 150 x 50 RS08S DX 250 x 50 RS08S DX 50 x 20 TO12S WX 100 x 20 TO12S WX 150 x 20 TO12S WX 250 x 20 TO12S WX 50 x 30 TO12S WX 75 x 30 TO12S05-L530WX 100 x 30 TO12S WX 150 x 30 TO12S WX 250 x 30 TO12S WX 100 x 50 TO12S DX 150 x 50 TO12S DX 250 x 50 TO12S DX 50 x 20 OS12S WX 100 x 20 OS12S WX 150 x 20 OS12S WX 250 x 20 OS12S WX 50 x 30 OS12S WX 75 x 30 OS12S05-L530WX 100 x 30 OS12S WX 150 x 30 OS12S WX 250 x 30 OS12S WX 100 x 50 OS12S DX 150 x 50 OS12S DX 250 x 50 OS12S DX

8 YMC-Actus 49 Ordering Information High durability semi-preparative columns Packing material Particle size [µm] Pore size [nm] Column size length x ID [mm] Product Code ODS-A S-5 12 ODS-AQ S-5 12 YMCbasic S-5 50 x 20 AA12S WX 100 x 20 AA12S WX 150 x 20 AA12S WX 250 x 20 AA12S WX 50 x 30 AA12S WX 75 x 30 AA12S05-L530WX 100 x 30 AA12S WX 150 x 30 AA12S WX 250 x 30 AA12S WX 100 x 50 AA12S DX 150 x 50 AA12S DX 250 x 50 AA12S DX 50 x 20 AQ12S WX 100 x 20 AQ12S WX 150 x 20 AQ12S WX 250 x 20 AQ12S WX 50 x 30 AQ12S WX 75 x 30 AQ12S05-L530WX 100 x 30 AQ12S WX 150 x 30 AQ12S WX 250 x 30 AQ12S WX 100 x 50 AQ12S DX 150 x 50 AQ12S DX 250 x 50 AQ12S DX 50 x 20 BA99S WX 100 x 20 BA99S WX 150 x 20 BA99S WX 250 x 20 BA99S WX 50 x 30 BA99S WX 75 x 30 BA99S05-L530WX 100 x 30 BA99S WX 150 x 30 BA99S WX 250 x 30 BA99S WX 100 x 50 BA99S DX 150 x 50 BA99S DX 250 x 50 BA99S DX Guard cartridges Packing material Particle size [µm] Pore size [nm] Column size length x ID [mm] Product Code Triart C18 S-5 12 Pro C18 S-5 12 Hydrosphere C18 S-5 12 Pro C18 RS S-5 8 Pro C8 S-5 12 ODS-A S-5 12 ODS-AQ S-5 12 S Triart Prep C18-S S Triart Prep C8-S S Omega S-10 YMCbasic S-5 10 x 20 TA12S CC 10 x 30 TA12S CC 10 x 20 AS12S CC 10 x 30 AS12S CC 10 x 20 HS12S CC 10 x 30 HS12S CC 10 x 20 RS08S CC 10 x 30 RS08S CC 10 x 20 OS12S CC 10 x 30 OS12S CC 10 x 20 AA12S CC 10 x 30 AA12S CC 10 x 20 AQ12S CC 10 x 30 AQ12S CC 10 x 20 TAS12S CC 10 x 30 TAS12S CC 10 x 20 TAS12S CC 10 x 30 TAS12S CC 10 x 20 TOS20S CC 10 x 30 TOS20S CC 10 x 20 OMG99S CC 10 x 30 OMG99S CC 10 x 20 BA99S CC 10 x 30 BA99S CC Guard cartridges holder: 20 mm guard column ID: XPCHSPW2; 30 mm guard column ID: XPCHSPW3 * Application data by courtesy YMC Co., Ltd.

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN Fang Xia, Jie Y. Cavanaugh, Darcy Shave, Gary Izzo, Michael Savaria, Thomas Grady, Markus Wanninger, Donald Ziniti, Brad Francis,

More information

5 µm Preparative HPLC Columns

5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns 5 µm Preparative HPLC Columns Your only as good as your last product. ~ James Browne, Continuous Improvement Program Manager/Lean/6-Sigma Program Manager, Wexford, Ireland

More information

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent Extended ph range from 1-10 provide longer lifetimes with harsh mobile phases Novel bonding reduces residual silanols which cause peak tailing Polymer coated capsule type silica Excellent selectivity for

More information

InertSustainSwift. Achieving separations faster than ever before

InertSustainSwift. Achieving separations faster than ever before InertSustainSwift TM C8 Achieving separations faster than ever before InertSustainSwift C8 HPLC Columns Increasing Efficiency, Throughput and Productivity InertSustainSwift C8 columns are designed to deliver

More information

YMC Phases Preparative Scale. YMC Europe GmbH Friederike Becker

YMC Phases Preparative Scale. YMC Europe GmbH Friederike Becker YMC Phases Preparative Scale YMC Europe GmbH Friederike Becker Production Facility Komatsu / Ishikawa Province Japan Courtesy of Courtesy YMC Europe of YMC GmbH Europe GmbH YMC will never knowingly change

More information

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS MS Identification of Trace level Impurities from a Non-MS Compatible Mobile Phase Using ACQUITY UPLC System with 2D Technology by Heart-cutting and Online Sample Concentration Bronsky Gopinadh, Dilshad

More information

VERITY Purification Systems Build the perfect system to fit your research

VERITY Purification Systems Build the perfect system to fit your research VERITY Purification Systems Build the perfect system to fit your research SPEC SHEET PURIFICATION VERITY PURIFICATION SYSTEMS WITH VERITY 3011 ISOCRATIC PUMP MAKE YOUR LAB LIFE EASIER From automated GPC

More information

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 ) Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Giorgis Isaac, 2 and Larry T. Taylor 1 1 Department

More information

Prep Flash TLC. Preparative Chromatography

Prep Flash TLC. Preparative Chromatography Prep Flash TLC Preparative Chromatography........ 148 183 Introduction...................... 148 151 Columns....................... 152 171 GraceAlpha Columns 152 155 Vydac MS Columns 156 157 Vydac TP

More information

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 129 Infinity II HDR-DAD Impurity Analyzer Solution Application ote Small Molecule Pharmaceuticals Author Sonja Schneider Agilent Technologies,

More information

Sample Pretreatment, Accessories

Sample Pretreatment, Accessories 11 Sample Pretreatment, Accessories Sample pretreatment -------------------------- 144 Column protection----------------------- 145~147 Tubing parts ------------------------------ 148~151 Empty columns

More information

Quality-by-Design in Method Development. Mijo Stanic General Manager and Technical Director

Quality-by-Design in Method Development. Mijo Stanic General Manager and Technical Director Quality-by-Design in Method Development Mijo Stanic General Manager and Technical Director Agenda Chromicent who we are Traditional vs. Systematic strategies for method development QbD a new approach in

More information

Determination of Sudan Dyes I IV in Curry Paste

Determination of Sudan Dyes I IV in Curry Paste Determination of Sudan Dyes I IV in Curry Paste Suparerk Tukkeeree and Jeffrey Rohrer 2 Thermo Fisher Scientific, Bangkok, Thailand; 2 Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 23 Key

More information

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis Joan M Stevens, Ph.D., Mark Crawford and Greg Robinson Single Presenter Name Abstract:

More information

Spring Column Hardware

Spring Column Hardware Spring Column Hardware For Use with Multipacker Packing Instruments High-efficiency axial compression packing mechanism Extend media lifetime Mobile Dynamic Axial Compression (DAC) column Easily packed

More information

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide Accuracy Starts Here Agilent Captiva Filtration Selection Guide TAbLe of CoNTeNTS Tips & Tools Learn the core concepts surrounding Solid Phase Extraction and best practices for Sample Prep. View the video

More information

Achieving separations faster than ever before

Achieving separations faster than ever before InertSustainSwift TM C8 Achieving separations faster than ever before InertSustainSwift C8 HPLC Columns Increasing Efficiency, Throughput and Productivity InertSustainSwift C8 columns are designed to deliver

More information

Analyte Focusing in Elevated Temperature HPLC

Analyte Focusing in Elevated Temperature HPLC Analyte Focusing in Elevated Temperature HPLC Jody Clark Brian Jones, Stephanie J. Marin, Dale Felix Selerity Technologies, Inc. Salt Lake City, UT 84104 www.selerity.com Introduction HPLC at extreme temperatures

More information

Technical Overview. Introduction

Technical Overview. Introduction Performance characteristics of the Agilent 129 Infinity Binary Pump More resolution and speed for conventional, superficially porous and sub-2 µm column packing material Technical Overview Introduction

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over The Agilent 12 Series high performance autosampler SL: Area precision, injection volume linearity, imum accessible volume, carry-over Technical Note 8 6 4 2.5 1 Introduction A main performance criterion

More information

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure TECHNICAL REPORT Modifying Agilent 1100 HPLC Systems to Achieve UHPLC-like performance with HALO Fused-Core Columns Agilent 1100 HPLC system With a few modifications, an Agilent 1100 HPLC can produce UHPLC-like

More information

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE gilent InfinityLab LC urification Solutions SELECTION GUIDE GILENT INFINITYLB LC URIFICTION SOLUTIONS EFFICIENT LC URIFICTION SOLUTIONS FOR NLYTICL TO RERTIVE SCLE gilent InfinityLab LC urification Solutions

More information

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE AN HPLC THAT WORKS AS HARD AS YOU DO Confidence in your results comes with high performance, day-to-day reliability, and overall system robustness.

More information

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve Technical Note This Technical Note describes the purpose, installation, and configuration and use of a diverter valve

More information

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION Waters Advanced Purification (AP) series of glass columns are constructed of biocompatible glass and polymeric materials and can be easily used with

More information

HyperShear TM HPLC Mixers

HyperShear TM HPLC Mixers HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex shear mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume

More information

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve Online sample cleanup on the Agilent 129 Infinity LC using a built in 2-position/6-port valve Analysis of Sudan red compounds in paprika powder Application Note Food Authors Angelika Gratzfeld-Huesgen

More information

GENERAL CATALOGue 2013/2014. HPLC Bio-LC

GENERAL CATALOGue 2013/2014. HPLC Bio-LC GENERAL CATALOGue 2013/2014 UHPLC HPLC Bio-LC 2 Introduction Worldwide Availability If any of your requirements for selecting a chromatography vendor are not addressed in this general catalogue, please

More information

S 1125 HPLC Pump System

S 1125 HPLC Pump System Routine S 170 EXPERT HPLC HPLC System SYSTEMS 500 The Sykam ROUTINE HPLC System S 500 is intended for all routine analysis. The system configuration is highly variable and several upgrade options make

More information

HPLC SYSTEM S 500 SERIES

HPLC SYSTEM S 500 SERIES HPLC SYSTEM S 500 SERIES The Sykam HPLC System S 500 Series is intended for all routine analysis as well as for the ambitious analyst. The system configuration is highly variable and several upgrade options

More information

HPLC System S 600 Series

HPLC System S 600 Series HPLC System S 600 Series The Sykam HPLC System S 600 Series is intended for the ambitious analyst. The system configuration is highly variable and several upgrade options make this system suitable for

More information

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet 1. Description The Agilent Dynamax modular HPLC column system uses a unique technology, Dynamic, to maintain the structure of the packed

More information

QuickSplit TM Flow Splitters

QuickSplit TM Flow Splitters Quick TM Flow ters Quick TM Flow ter Features: Fluid resistor technology eliminates tedious adjustments to capillary tubing for split ratio optimization ratios are stable and reproducible, and not affected

More information

14 Chromatography Columns

14 Chromatography Columns 14 Chromatography Columns LC Columns Selection Guide Omnifit Labware columns offer the maximum performance for low to mid pressure liquid chromatography or flow chemistry applications. Simple to assemble,

More information

HIGH PRESSURE SWITCHING VALVES

HIGH PRESSURE SWITCHING VALVES HIGH PRESSURE SWITCHING VALVES Rheodyne offers high pressure switching valves to simplify procedures and improve the speed, resolution, and sensitivity of HPLC analysis. The switching valves are available

More information

HyperShear TM HPLC Mixers

HyperShear TM HPLC Mixers HyperShear TM HPLC s HyperShear TM HPLC Features: Static or Dynamic s with highly efficient vortex sheer mixing Reduce baseline noise, increase sensitivity, and improve gradient accuracy Mixing volume

More information

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers HyperShear TM HPLC and UHPLC s Reduce baseline noise, increase sensitivity and improve gradient accuracy Decrease mixing and delay volume without sacrificing mixing efficiency Increase reaction efficiency

More information

The Only No Compromise

The Only No Compromise C196-E071 The Only No Compromise Best UHPLC for the Next Era Nexera is revealed as the next generation Shimadzu LC, achieving a new greater level of performance. Nexera hardware meets all analysis requirements:

More information

Application Note. Authors. Abstract. Energy & Chemicals

Application Note. Authors. Abstract. Energy & Chemicals Determination of Aromatic Content in Diesel Fuel According to ASTM D5186 Enhancing the Agilent 126 Infi nity Analytical SFC System with a Flame Ionization Detector Application Note Energy & Chemicals Authors

More information

Comparison of LC/MS/MS and GC/MSD Analyses of Pesticide Residues in Food Products when Using the QuEChERS Sample Preparation Technique

Comparison of LC/MS/MS and GC/MSD Analyses of Pesticide Residues in Food Products when Using the QuEChERS Sample Preparation Technique Comparison of LC/MS/MS and GC/MSD Analyses of Pesticide Residues in Food Products when Using the QuEChERS Sample Preparation Technique Monika Kansal, A. Carl Sanchez, Michael Rummel, and Art Dixon Phenomenex,

More information

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell Alexandra Manka and Holger Franz Thermo Fisher Scientific, Germering, Germany Technical

More information

A Single Method for the Direct Determination of Total Glycerols in All Biodiesels Using Liquid Chromatography and Charged Aerosol Detection

A Single Method for the Direct Determination of Total Glycerols in All Biodiesels Using Liquid Chromatography and Charged Aerosol Detection A Single Method for the Direct Deteration of Total Glycerols in All Biodiesels Using Liquid Chromatography and Charged Aerosol Detection Marc Plante, Bruce Bailey, Ian N. Acworth, Christopher Crafts, Thermo

More information

LEVONORGESTRELUM LEVONORGESTREL (May 2015)

LEVONORGESTRELUM LEVONORGESTREL (May 2015) May 2015 RESTRICTED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 LEVONORGESTRELUM LEVONORGESTREL (May 2015) DOCUMENT FOR DISCUSSION

More information

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New! Inlet Solvent Filters Filters and Degassers General Use Inlet Solvent Filters Large Surface Areas disposable µm, 0 µm, and 0 µm Pore Sizes Available General Use and Prep Filters for Higher Flow Applications

More information

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations. Simplify your search for COLUMN HARDWARE Discover how to maximize results with Isolation Technologies column hardware and accessories that are specifically engineered to meet critical UHPLC, HPLC, and

More information

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC Application Note Energy and Fuels Authors Detlef Wilhelm Anatox GmbH & Co. KG Fürstenwalde, Germany Udo Huber Agilent

More information

Fixed Flow Splitter *

Fixed Flow Splitter * Fixed Flow * *Patent Pending Analytical Scientific Instruments Fluid resistor technology eliminates tedious adjustments to capillary tubing to change split ratios. Easy to use interchangeable fluid resistors

More information

Preparative Supercritical/Subcritical Fluid (SFC) Chromatography. Method Development Solvent effects Particle size

Preparative Supercritical/Subcritical Fluid (SFC) Chromatography. Method Development Solvent effects Particle size Preparative Supercritical/Subcritical Fluid (SFC) Chromatography Method Development Solvent effects Particle size 37 Preparative Supercritical (Subcritical) Fluid Chromatography: Benefits CO 2 is miscible

More information

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO 8 SupelPRO Valves Order:.800..00 Technical Service:.800.9.0 Web: www.sigma-aldrich.com/supelco SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled,

More information

HyperShear TM HPLC and UHPLC Mixers

HyperShear TM HPLC and UHPLC Mixers HyperShear TM HPLC and UHPLC s HyperShear TM HPLC and UHPLC Features: Micro Flow, Low Flow, Analytical Flow, High Flow and Combo Series Reduce baseline noise, increase sensitivity and improve gradient

More information

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method 2016 International Conference on Applied Mechanics, Mechanical and Materials Engineering (AMMME 2016) ISBN: 978-1-60595-409-7 Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel

More information

Revision of the Monograph on Estradiol Valerate. Draft Proposal for The International Pharmacopoeia (July 2018) DRAFT FOR COMMENTS

Revision of the Monograph on Estradiol Valerate. Draft Proposal for The International Pharmacopoeia (July 2018) DRAFT FOR COMMENTS July 2018 Draft document for comments 1 2 3 4 5 Revision of the Monograph on Estradiol Valerate (ESTRADIOLI VALERAS) Draft Proposal for The International Pharmacopoeia (July 2018) DRAFT FOR COMMENTS Should

More information

MET-Biodiesel Capillary GC Columns

MET-Biodiesel Capillary GC Columns MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What

More information

Monolithic silica columns: benefits and applications of Chromolith HPLC columns. Dr. Rod McIlwrick Merck KGaA, Darmstadt

Monolithic silica columns: benefits and applications of Chromolith HPLC columns. Dr. Rod McIlwrick Merck KGaA, Darmstadt Monolithic silica columns: benefits and applications of Chromolith HPLC columns Dr. Rod McIlwrick Merck KGaA, Darmstadt Merck Solvents & Chromatography August 2006 Dr. Rod McIlwrick / PLS LB ACB Page 2

More information

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Extended range HPLC has been investigated for many years; however, progress was delayed because of

More information

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany Determination of Aromatic Hydrocarbons in Petroleum Middle Distillates with the Agilent Infinity Binary HPLC System with RID Detection According to IP9()/ASTM D9 Application Note Energy & Chemicals - Petrochemicals

More information

The Vanquish Platform: Improved Throughput and Resolution of Xanthones in Mangosteen Pericarp

The Vanquish Platform: Improved Throughput and Resolution of Xanthones in Mangosteen Pericarp The Vanquish Platform: Improved Throughput and Resolution of Xanthones in Mangosteen Pericarp Qi Zhang, Bruce Bailey, Marc Plante, and Ian Acworth Thermo Fisher Scientific, Chelmsford, MA, USA Overview

More information

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument APPLICATION NOTE 72598 High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument Authors Nicola McGillicuddy, 1 Amy Farrell, 1 Sara Carillo, 1 Martin

More information

sensitive simple small From the Leader in Evaporative Light Scattering Detection Grace Davison Discovery Sciences Brochure #531 GEN

sensitive simple small From the Leader in Evaporative Light Scattering Detection Grace Davison Discovery Sciences Brochure #531 GEN sensitive Most sensitive ELSD available simple Easiest to use and maintain small Integrates easily with any HPLC Grace Davison Discovery Sciences Brochure #5 From the Leader in Evaporative Light Scattering

More information

EGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer

EGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer EGC II K 2 Cartridge Electrolytic ph Modifier EGC Carbonate Mixer PRODUCT MANUAL FOR THE EGC II K 2 CARTRIDGE EGC II K 2 CARTRIDGE, P/N 058904 ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N 063175 EGC CARBONATE

More information

NEW HPLC - SYSTEM LINE

NEW HPLC - SYSTEM LINE NEW HPLC - SYSTEM LINE S c h a m b e c k S F D G m b H Drieschweg 13A D-53604 Bad Honnef/Germany Phone: +49 2224 9239-0 E-Mail: info@schambeck-sfd.com Internet: www.schambeck-sfd.com S 9425 HPLC solvent

More information

Phase Distribution of Ethanol, and Water in Ethyl Esters at K and K

Phase Distribution of Ethanol, and Water in Ethyl Esters at K and K Phase Distribution of Ethanol, and Water in Ethyl Esters at 298.15 K and 333.15 K Luis A. Follegatti Romero, F. R. M. Batista, M. Lanza, E.A.C. Batista, and Antonio J.A. Meirelles a ExTrAE Laboratory of

More information

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science ÄKTA system Training Guide Purifier 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bio science ÄKTApurifier Buffers Injector Box Monitor Conductivity ph On-line Filter UV Detector

More information

Using the PSD for Backflushing on the Agilent 8890 GC System

Using the PSD for Backflushing on the Agilent 8890 GC System Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped

More information

PrimeLine TM HPLC Pumps

PrimeLine TM HPLC Pumps PrimeLine TM HPLC Pumps Isocratic Model 501 Gradient System 500G PrimeLine TM Isocratic and Gradient HPLC Pumps Feature: Self-priming pump head requires no manual priming Patented Floating Pump Seal design

More information

Glass Columns for Laboratory and Pilot Scale Liquid Chromatography

Glass Columns for Laboratory and Pilot Scale Liquid Chromatography Glass Columns for Laboratory and Pilot Scale Liquid Chromatography 1 Content 1. ECO PLUS Glass Columns...3 1.1 Highlights...3 1.2 Characteristics...3 1.3 Available Versions...4 1.4 Ordering Information...4

More information

SUPPRESSION IN ANALYSIS OF ARTIFICIAL SWEETENERS WITH

SUPPRESSION IN ANALYSIS OF ARTIFICIAL SWEETENERS WITH APPROACHES TO DECREASE ION SUPPRESSION IN ANALYSIS OF ARTIFICIAL SWEETENERS WITH UPLC-TQ MS Noora Perkola Finnish Environment Institute 3rd Nordic MS Symposium September 12 2012, Jurmala, Latvia ARTIFICIAL

More information

ACE. Intelligent Solutions for Method Development. Method Development Kits. ACE UHPLC and HPLC Columns

ACE. Intelligent Solutions for Method Development. Method Development Kits. ACE UHPLC and HPLC Columns Buy 1 column and get up to 2 columns FREE* *of the same particle size and column dimensions ACE Method Development Kits Intelligent Solutions for Method Development UHPLC and HPLC method development kits

More information

DIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start

DIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start DIONEX ELUENT GENERATOR CARTRIDGE DIONEX HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start 1. Preparation for Installation of Dionex If installing a Thermo Scientific Dionex and Thermo

More information

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract. Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers Application Note Abstract Versa With the rising prices of fossil fuels, more emphasis is being put on renewable resources

More information

URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C)

URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C) O NH O NH O. GENERAL INFORMATION IUPAC Name: 3'-carbamoylbiphenyl-3-yl cyclohexylcarbamate CAS#: 56-08-6 Synonyms: Source: Appearance: UV max (nm): KDS-03 DEA Reference Material Collection White powder

More information

Liquid Chromatography

Liquid Chromatography SCINTOMICS Liquid Chromatography Always the right system for your needs. SCINTOMICS: Always the right system for your needs Advanced Research Daily QC Routine and beyond High Performance analytical/semi-preparative

More information

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment chromatography Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment Product Specifications Thermo Scientific Dionex UltiMate 3000 products are UHPLC compatible by design, establishing

More information

*Order ferrules separately. Outlet Splitter. Outlet Splitter 14898

*Order ferrules separately. Outlet Splitter. Outlet Splitter 14898 Capillary Connectors Universal Capillary Connectors One size fits tubing from 0.25mm i.d. to 0.53mm i.d. Available in straight or Y configurations Capillary connectors form a gas-tight seal when heated

More information

Agilent Multimode Inlet for Gas Chromatography

Agilent Multimode Inlet for Gas Chromatography Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything

More information

78 동방하이테크상사 T.(02) F.(02)

78 동방하이테크상사  T.(02) F.(02) 78 동방하이테크상사 http://www.allpump.co.kr T.(0)7-9 F.(0)7-9 00--7 Introduction to Introduction Rheodyne valves fit virtually any high-pressure flow control application. As you ll see from the table below and

More information

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )

PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N ) CRD 200 Product Manual Page 1 of 18 PRODUCT MANUAL FOR CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N 062983) CRD 200 (2 mm) (P/N 062986) Dionex Corporation, 2006 Document No. 065068 Revision 04 November

More information

Adjustable Flow Splitter *

Adjustable Flow Splitter * Adjustable Flow Splitter * *Patent Pending Analytical Scientific Instruments Adjustable metering valve enables precise direct control over split ratios. Fluid resisr technology eliminates tedious adjustments

More information

ACQUITY UPLC I-Class System Specifications

ACQUITY UPLC I-Class System Specifications ACQUITY UPLC I-Class System s Revision A Copyright Waters Corporation 2011 All rights reserved Copyright notice 2011 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA AND IN IRELAND. ALL RIGHTS

More information

Isolation/Purification. Drug Development. Drug Discovery

Isolation/Purification. Drug Development. Drug Discovery Isolation/Purification Drug Development Drug Discovery XTerra Columns The Most Successful Column in ver 0 Years of Stationary Phase Technology The universal acceptance by pharmaceutical scientists in drug

More information

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL 1993 Dionex Corporation Document No. 034859 Revision 02 September 1993 1993 Dionex Corporation All rights reserved worldwide Printed in the United States

More information

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications C196-E081C Ultra High Performance Liquid Chromatograph Nexera X2 Specifications Specifications System Controllers CBM-20A / 20Alite CBM-20A (228-45012-XX) CBM-20Alite (228-45011-XX) Connectable units Solvent

More information

n multi-residue analysis of pesticides olfgang Schwack, Claudia Oellig niversity of Hohenheim

n multi-residue analysis of pesticides olfgang Schwack, Claudia Oellig niversity of Hohenheim ean-up in pesticide residue analysis lanar solid phase extraction a new clean-up concept n multi-residue analysis of pesticides olfgang Schwack, audia ellig niversity of Hohenheim International Symposium

More information

QuickSplit TM Adjustable Flow Splitters Analytical Splitters Analytical range, 0.1 ml/min. to 5 ml/min. input flow, calibration flow rate 1.0 ml/min.

QuickSplit TM Adjustable Flow Splitters Analytical Splitters Analytical range, 0.1 ml/min. to 5 ml/min. input flow, calibration flow rate 1.0 ml/min. Adjustable Flow ters Applications Post-column splitting is fairly straight forward. Like pre-column flow splitting, any significant additional pressure (resistance) down stream from the splitter may affect

More information

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell Application Note Consumer Products Authors Gerd Vanhoenacker,

More information

4001 Transesterification of castor oil to ricinoleic acid methyl ester

4001 Transesterification of castor oil to ricinoleic acid methyl ester 4001 Transesterification of castor oil to ricinoleic acid methyl ester castor oil + MeH Na-methylate H Me CH 4 (32.0) C 19 H 36 3 (312.5) Classification Reaction types and substance classes reaction of

More information

DANI Transformer Oil Gas Analyzer

DANI Transformer Oil Gas Analyzer DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil

More information

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares Competitive Comparison Maximize Performance and Minimize Maintenance with LC Spares high-quality spare parts and preventative maintenance kits Regular replacement of crucial parts can help keep your HPLC

More information

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different

More information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville

More information

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN1413:211 Method Application Note Author James D. McCurry, Ph.D. Agilent Technologies Abstract

More information

FITTINGS, LOOPS, AND VALVE ACCESSORIES

FITTINGS, LOOPS, AND VALVE ACCESSORIES FITTINGS, LOOPS, AND VALVE ACCESSORIES Fittings Rheodyne offers a variety of fittings. They differ in material of construction, tubing size, and pressure rating. Materials/Biocompatibility. 316 stainless

More information

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 Using a scale to count Upchurch Scientific frits in Oak Harbor, WA. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159 156 Inlet Solvent

More information

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down

More information

Ultra High Performance Fittings. Fittings Connectors Kits

Ultra High Performance Fittings. Fittings Connectors Kits Ultra High Performance Fittings Fittings Connectors Kits Ultra High Performance Fittings Introduction Ultra Performance Fittings Introduction high Temperature Versions Withstand Temperatures up to 200ºC

More information

ACQUITY UPLC I-Class System with 2D Technology

ACQUITY UPLC I-Class System with 2D Technology ACQUITY UPLC I-Class System with 2D Technology The Waters ACQUITY UPLC I-Class System with 2D Technology allows chemists to increase sensitivity and selectivity, eliminate unwanted interferences, characterize

More information

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour

More information

Supplementary Material

Supplementary Material Arkivoc 2017, v, 1-32 upplementary Material olvent-free synthesis of (poly)thiacalix[n]arenes: the evaluation of possible mechanism based on semi-preparative HPL separation and mass-spectrometric investigation

More information

Gilson, Inc. Table of Contents. Solid Phase Extraction Systems HPLC: Systems 2 9. Liquid Handlers HPLC: Liquid Handlers/Injectors 10 14

Gilson, Inc. Table of Contents. Solid Phase Extraction Systems HPLC: Systems 2 9. Liquid Handlers HPLC: Liquid Handlers/Injectors 10 14 Gilson, Inc. Table of Contents Designed for purification and engineered for science, Gilson, Inc. provides high quality, dependable solutions for today s demanding liquid chromatography, solid phase extraction,

More information