energy management systems Current Transformers

Size: px
Start display at page:

Download "energy management systems Current Transformers"

Transcription

1 energy management systems 05 Current Transformers

2

3 CURRENT TRANSFORMERS Current transformers with analogue output page 5/1 Busbars page 5/5 Current transformers ic Line page 5/6 Protective current transformers ic Line page 5/ Current transformers AST Line page 5/19 Certificable current transformers page 5/37 Summation current transformers page 5/43 Split core current transformers page 5/45 Current transformers with fused terminal page 5/49 Accessories page 5/50 Flexible current transformers on request

4 CURRENT TRANSFORMERS Current transformers are electrical equipment, that convert primar currents to proportional secondary currents that are appropriate to the connected measuring instruments. Current transformers have a primary winding to which the current to be measured is fed. Measuring instruments are connected to a secondary winding. Current transformers are used for measuring and protecting applications. It is recommended to apply current transformers for currents of 40 A or higher..

5 CURRENT TRANSFORMERS WITH ANALOGUE OUTPUT SMU SMU/I Current Transformer and transducer in one housing Up to 600 A Standard analogue output 0(4)20 ma / 0(2) V SMU SMU/I Application The measured quantity (i.e. primary current) is galvanically insulated (5kV/1 min), rectified (mean value principle) and converted into a proportional and loadindependent DC signal current (or voltage). The passive type SMU does not require auxiliary supply. The active SMU/I connects to a auxiliary supply of 230 VAC or 24 VDC. These information have to indicated on the order. Dimensions SMU SMU: SMU/I: Design with 020 ma or 0 V output without auxiliary supply Design with 420 ma output and auxiliary supply 230 VAC or 24 VDC (indication on the order) Snapon mounting for DIN rail, mounting brackets for mounting plates and screws for the busbar fixing are included in delivery. SMU/I SMU SMU/I Available metering ranges SMU SMU/I Primary Output current 020mA Output 0V Output 420mA without auxiliary supply 230 VAC 24 VDC A Other primary current on request. Connection diagrams 5/1

6 CURRENT TRANSFORMERS WITH ANALOGUE OUTPUT SMK SMG Current Transformer and transducer in one housing Up to 00 A Standard analogue output 0(4)20 ma / 0(2) V SMK / SMG Application Dimensions The measured quantity (i.e. primary current) is galvanically insulated (5 kv/1 min), rectified (mean value principle) and converted into a proportional and loadindependent DC signal current (or voltage). The passive type SMK/SMG does not require auxiliary supply. The active SMK/I or SMG/I connects to a auxiliary supply of 230 VAC or 24 VDC. These information have to indicated on the order. SMK SMG: SMK/I SMG/I: Design with 020 ma or 0 V output without auxiliary supply Design with 420 ma output and auxiliary supply 230 VAC or 24 VDC (indication on the order) SMK SMK/I Screws for the busbar fixing are included in delivery. SMK SMG Available metering ranges SMK SMK/I SMG SMG/I Primary current Output 020mA Output 0V Output 420mA Output 020mA Output 0V Output 420mA without auxiliary supply 230 VAC 24 VDC without auxiliary supply 230 VAC 24 VDC A Other primary current on request. SMG SMG/I Connection diagrams SMK SMG SMK/I SMG/I 5/2

7 CURRENT TRANSFORMERS WITH ANALOGUE OUTPUT Technical Data SMU, SMK, SMG according to DIN EN Current output ma ma current limiting None About 22,5 ma Opencircuit voltage About 30 V About 30 V Output load ohm ohm (or) voltage output 0... V 2... V Limiting current None About 22,5 ma Limiting voltage About 18 V About 18 V Outpur resistance 500 ohm < 30 ohm Input A (metering range according to the table) Working range % % frequency of input quantity Hz Hz Overcharge lasting + 20 % + 20 % Short duration (1s) 20 times 40 times Transmission Accuracy class index Ripple (peaktopeak) 0 ohm: < 6 % < 1 % 500 ohm: < 1 % Response time 0 ohm: < 0.4 s < 0. s 500 ohm: < 0.8 s Drift vs. temperature (0...45ºC) < 1 % < 200 ppm/ºk Drift vs. auxiliary < 20 ppm/v Auxiliary supply AC Auxiliary supply DC Internal consumption measuring input < 3 VA < 1 VA Nominal consumption auxiliary supply < 3 VA Housing and fixing Mounting Insulation class Temperature resistance Burning rate Unbreakable black current transformer casing of polyamid Busbar, screwor snpaon mopunting for cap rail E (IEC85)...00 A (metering range according to the table) % de 230 V AC % de 24 V DC 1ºC according to UL 746B oder 148º according to DIN ISO 306B Protection class V0 UL94 or level IIb according to DIN VDE 0304 Schutzart Reference conditions (in accordance with IEC 60688) Ambient temperature... 30ªC Frequency of measuring size 50 Hz, +/ 2% Wave form of measuring size Sinusoidal, form factor 1.111, +/ 0.5% Output load 0.5 x rated impedance, +/ 1 % Auxiliary supply Nominal voltage +/ 2 % EMV Environmental conditions (according to IEC 60688) Transport and storage temperature 40º... 70ºC Working temperature... 55ºC Relative humidity Until 93% Elevation Housing IP40, clamps IP20 according to DIN EN 632, DIN VDE 1, DIN 40050, VGB4 Inspections according to EN and EN No radiation according to EN No harmonics according to EN Interference resistance according to EN 60042, ESD (electrostatic discharge), severity level cl.3, test voltage 8kV Interference resistance according to EN 60043, (highfrequent electromagnetic panels) Interference resistance according to EN 60044, burst (fast, transient electrical disturbance variable) severity level cl.3, test voltage 2kV Interference resistance according to EN 60044, Surge ( surge voltage), severity level cl.3, test voltage 2kV Until 2000 n NN Safety (according to DIN EN 61 and DIN EN 50178) Doubled or amplified insulation (protection class II according to DIN VDE 06) Pollution degree 2 Overvoltage category 600V (power line to neutral or working voltage) test voltage 5.2 kv/1 min 5/3

8 CURRENT TRANSFORMERS NOTES 5/4

9 BUSBARS CUcable consumption between the measurement instrument and the current transformer For secondary primary rated current of 5 A conductor crosssection mm 2 P = I 2. 2 x L q cu. 56 VA P = consumption in VA (2wired line) Distance in m ,5 0,58 1, 2,31 3,46 4,62 5,77 2,5 0,36 0,71 1,43 2,14 2,86 3,57 4 0,22 0,45 0,89 1,34 1,79 2,24 6 0, 0,30 0,60 0,89 1,19 1,49 0,09 0,18 0,36 0,54 0,71 0,89 For secondary rated current of 1 A conductor crosssection mm 2 P = consumption in VA (2wired line) Distance in m ,36 0,71 1,43 2,14 2,85 3,57 1,5 0,23 0,46 0,92 1,39 1,85 2,31 2,5 0,14 0,29 0,57 0,86 1,14 1,43 4 0,09 0,18 0,36 0,54 0,71 0,89 6 0,06 0,12 0,24 0,36 0,48 0,60 0,04 0,07 0,14 0,21 0,29 0,36 L = Distance in m q cu = Conductor crosssection in mm 2 busbars To pay attention to the selection of current transformers: 1. the primary and secondary ratio of the current transformer; 2. the burden in VA. The burden is calculated of all connected meters and the wires as well. 3. the class accuracy according to VDE 0414 and IECdeterminations. For calculated measurement class 0.5. For internal measuring or protection relays class 1 and 3. Copper bars ampacity according to DIN Ampacity according to DIN Width x thickness mm Cross section mm 2 Weight 1) kg/m 1 I 1) Calculated with density of 8,9 kg/dm3 Continuous current in A / alternating current up to 60 Hz coated blank numbers of bars numbers of bars 12 x 2 23,5 0, Material: ECu or other materials according to DIN Part 3 Preferable used material: Flat bar with rounded edge according to DIN Part 3 Continousely currents for bus bars of ECu with rectangle crosssection for indoor use at 35 C air temperatur and 65 C bus bar temperatur, vertical position of the bus bar width; Bus bar packets with distances between bus bars of one time bus bar width. For AC current and bus bar packets the distances between bus bars should be > 0,8 x centre to centre distance of the main primary conductors. Integrated short bus bars in current transformers to be connected to main bus bars can be higher loaded than mentioned in the table if the rest of the bus bar system is higher designed than mentioned in the table (DIN 43671). 2 II x 2 29,5 0, x 3 44,5 0, x 2 39,5 0, x 3 59,5 0, x 5 99,1 0, x 199 1, x 3 74,5 0, x , x 3 89,5 0, x , x 299 2, x , x , x 399 3, x , x 499 4, x , x 599 5, x , x 799 7, x , x 999 8, x 1200, x , x , III 1 I 2 II 3 III s Design: brasscopper bar (electrocu) nickelplated With steal screws M12 x 35 (40) DIN 933 zinc plated and chromatized incl. washer, spring lock washer and hex nut Width x height x length (mm) Width x height x length (mm) Width x height x length (mm) 30x 6x 140 O 50x x 180 O 2x 50x x 220 O 30x 8x 160 O 50x x 220 O 2x 60x x 220 O 30x x 140 O 60x x 180 O 2x 80x x 240 O 30x x 160 O 60x x 240 O 2x0x x 240 O 40x 5x 140 O 80x x 240 O 40x 5x 160 O 0x x 240 O 40x x 140 O 40x x 160 O 50x x 140 O O Delivery period on request Copper tube Ø 22.5; length 34 mm Ø 22.5;length 36 mm 5/5

10 CURRENT TRANSFORMERS CLASSIC LINE General Characteristics Application Accuracy class index Current transformers convert an alternating current, usually of high value, into a proportional secondartcurrent of lower value, which is appropriate to be measured by standard instruments of rated currents 5 or 1 A. CELSA transformers are suitable for indoor use in lowvoltage networks, and they are built according to IEC and BS Current transformers are applied for measuring and protection. It is indicated to use current transformers for currents from 40A. According to IEC 60085, VDE0414 and UNE228 the current and the angle error are as follows: Accuracy Current error in % at In Loss angle in min. at In 0,05 In 0,02 In In 1,2 In 0,05 In 0,02 In In 1,2 In 0,5 1 0,75 0,5 0, , in 0,5 In = 3 in 0,5 In = 120 Accucary (according to IECn ) CELSA current transformers fulfil the specifications of the accuracy classes 0.5, 1 and 3 for the rated outputs indicated in the tables, in the same instrument. The accuracy of the current transformers of class 0.5 and 1 varies in any case between 25 % and 0 % of their rated burden for more than 2.5 VA; and between 50 % and 0 % for equal or less than 2.5 VA; however at least 1 VA. Constructive Characteristics Cases of selfextinguishing polycarbonate V0 according to UL 94. Sealable terminal cover included, made of clear polycarbonate, except for the types IBA and IBP. Double secondary terminals, for shortcircuiting the secondary winding before opening the measuring circuit. The IBO and IBO50 are wound primary transformers. Other types are bus type transformers. 0.5 is used for counters. 1is used for measurement and for internal connected counters. 3 is used for protection and for relays. Electrical Data (according to IEC ) Rated secondary current: 5 or 1 A Frequency range: Hz Highest voltage for equipment: 720 V Rated insulation level: 3 kv, 50 Hz during 1 minute Rated continuous thermal current: 1.2 times rated current Rated shorttime thermal current (Ith): 60 times rated current Rated dynamic current (1dyn): 2.5 times Ith Instrument security factor (FS): less than 5 Thermal class of insulation: according to IEC 60085: E (120 C) 5/6

11 CURRENT TRANSFORMERS CLASSIC LINE IBA Ø 16 mm 20 x 5 mm IBA Technical Features, Executions current A sec. 5A 0, sec. 1A 0, , ,25* , , , , , , , , ,25 3, ,25 3, , , , ,5 5 Accesories (see page 5/53): mounting feet / snap on mounting bracket EN *class 3 1 IBP Ø 22 mm 30 x mm IBP Technical Features, Executions current A sec. 5A sec. 1A 0, , , , , , , , , , ,25 2, ,25 2, ,5 2, ,5 2, ,5 3, ,5 3, , ,5 2, , ,5 3,75 Accesories (see page 5/53): mounting feet / snap on mounting bracket EN /7 5/7

12 CURRENT TRANSFORMERS CLASSIC LINE IB Ø 23 mm 30 x mm IB Technical Features, Executions current A sec. 5A 0, sec. 1A 0, , , , , , , , , , , , , , , , , ,75 7, ,75 7, , ,5 20 Included in delivery: Primary fixing device Accesories (see page 5/53): mounting feet / snap on mounting bracket EN IB50 The rated burden of this type is higher than the type IB. Ø 23 mm 30 x mm IB50 Technical Features, Executions current A sec. 5A 0, sec. 1A 0, ,25 3, ,25 3, , , ,75 7, ,75 7, , , Included in delivery: Primary fixing device Accesories (see page 5/53): mounting feet / snap on mounting bracket EN /8

13 CURRENT TRANSFORMERS CLASSIC LINE IBG For round conductor Ø 40 mm the type IBG/1 is available. IBG: Ø 30 mm IBG/1: Ø 40 mm 40 x mm IBG IBG/1 IBG Technical Features, Executions Primary rated current A IBG sec. 5A IBG/ ,5 1 IBG sec. 1A IBG/ , , , , , , , , , , , , , , ,5 7, ,5 7, Included in delivery: Primary fixing device (except IBG/1) Accesories (see page 5/53): Mounting feet / snap on mounting bracket EN ,5 1 IBG50 The rated burden of this current transformer is higher than the type IBG. Ø 30 mm 40 x mm IBG50 Technical Features, Executions current A sec. 5A 0, sec. 1A , ,5 5 0, ,75 7, ,75 7, ,75 7, ,75 7, , , Included in delivery: Primary fixing device Accesories (see page 5/53): Mounting feet / snap on mounting bracket EN /9

14 CURRENT TRANSFORMERS CLASSIC LINE IBR Ø 44 mm 50 x mm 2 x 40 x mm IBR Technical Features, Executions current A sec. 5A 0, sec. 1A , ,5 7, ,5 7, Included in delivery: Primary fixing device Accesories (see page 5/53): Mounting feet 1 IBR/1 Ø 44 mm 60 x 12 mm 2 x 50 x mm IBR/1 Technical Features, Executions current A sec. 5A 0, sec. 1A , ,5 7, ,5 7, Included in delivery: Primary fixing device Accesories (see page 5/53):Mounting feet 1 5/

15 CURRENT TRANSFORMERS CLASSIC LINE IER For round conducttors Ø 80 mm the type IER/1 is available Ø 50 (80) mm 80 x mm 2 x 60 x mm IER IER/1 IER/2 IER/3 IER Technical Features, Executions current A IER IER/ sec. 5A sec. 1A IER/2 IER/ IER IER/1 IER/2 0, IER/3 0, , , Included in delivery: Primary fixing device (except IER/1) 1 5/11

16 CURRENT TRANSFORMERS CLASSIC LINE IER/4 2 x 0 x mm IER/4 Technical Features, Executions current A 0,5 sec. 5A 1 0,5 sec. 1A 250 1,25 3,75 1,25 3, ,75 7,5 3,75 7, Included in delivery: Primary fixing device On request IRP 1 On request: Seconday terminals on the long side of the current transformer 0 x 20 mm IRP Technical Features, Executions current A sec. 5A sec. 1A 0, , Included in delivery: Primary fixing device 5/12

17 CURRENT TRANSFORMERS CLASSIC LINE IRM On request: Seconday terminals on the long side of the current transformer 2 x 0 x mm IRM Technical Features, Executions current A sec. 5A sec. 1A 0, , Included in delivery: Primary fixing device ICM 3 x 0 x mm 2 x 0 x 20 mm ICM Technical Features, Executions current A sec. 5A sec. 1A 0, , Included in delivery: Primary fixing device 5/13

18 CURRENT TRANSFORMERS CLASSIC LINE ICG 3 x 130 x 20 mm 4 x 130 x mm ICG Technical Features, Executions current A sec. 5A sec. 1A 0, , Included in delivery: Primary fixing device IBO WOUND PRIMARY CURRENT TRANSFORMER Form A Form B Form C IBO Technical Features, Executions current A sec. 5A , sec. 1A 0, Form C Form B Form A Accesories (see page 5/53): Mounting feet / snap on mounting bracket EN /14

19 PROTECTIVE CURRENT TRANSFORMERS CLASSIC LINE While measurement current transformers are used to go into saturation above the nominal current range (shown in the excess current limiting factor FS) to prevent the increasing of the secondary current in case of system fault (e. g. primary short circuit) and to protect the equipments in the secondary circuit, a protective c.t. is used to have a saturation far away from its nominal current range in order to protect the switchgear etc. by using distance relays, overcurrent relays etc. Rated accuracy classes are 5P and P. "P" means "protection". The excess current limiting factor (in %) is given behind the precision class. It means e.g.p5, if the primary current is five times higher than the nominal current, the negative deviation of the secondary current from the theoretically secondary current calculated by the ratio is not more than %. Application Protective current transformers convert an alternating current of high value into a lower, proportional one, in order to protect an installation by means of standard relays of rated currents 5 or 1A. CELSA transformers are suitable for indoor use in lowvoltage networks. They are built according to IEC and BS Accuracy (according to IEC ) CELSA manufactures protective current transformers of accuracy classes 5 P and P, with an accuracy limit factor of 5 or, for the rated outputs indicated in the tables. Constructive Characteristics Cases of selfextinguishing polycarbonate V0 according to UL94. Sealable terminal cover included, made of clear polycarbonate. Double secondary terminals, for shortcircuiting the secondary winding before opening the measuring circuit. All are bus type transformers and they include fixing clamps to the primary bar. Electrical Data (according to IEC ) Rated secondary current: 5 or 1 A Frequency range: 5060 Hz Highest voltage for equipment: 720 V Rated insulation level: 3 kv, 50Hz during 1 minute Rated continuous thermal current: 1,2 times rated current Rated shorttime thermal current (I th ): 60 times rated current Rated dynamic current (I th ): 2,5 times I th Accuracy limit factor: 5 or Thermal class of insulation, according to IEC60085: E (120 C) IB50 Protective current transformers Rated currents: A Secondary: 1 A / 5 A : Ø 23 mm : 30 x mm Dimensions: 76 x 5 x 50 mm IB50 Technical Features, Executions current A Rated burdens VA (.../5A,.../1A) 5P P 5P5 P5 75 1,25 1,25 0 2,5 2, ,25 1,25 2,5 2,5 0 1,25 1,25 3,75 3, ,25 1, ,5 2,5 7,5 7, ,5 3,75 7,5 7, ,25 1, ,25 1, ,25 1, Included in delivery: Primary fixing device Accesories (see page 5/53): Mounting feet / snap on mounting bracket EN /

20 PROTECTIVE CURRENT TRANSFORMERS CLASSIC LINE IBG50 Protective current transformers Rated currents: 0 00 A Secondary: 1 A / 5 A : Ø 31 mm : 40 x mm Dimensions: 76 x 5 x 50 mm IBG50 Technical Features, Executions current A Rated burdens VA (.../5A,.../1A) 5P P 5P5 P5 0 2,5 2, ,25 1,25 2,5 2, ,25 1, ,25 1, ,5 2, ,5 3, ,5 3, , , ,25 Included in delivery: Primary fixing device Accesories (see page 5/53): Mounting feet / snap on mounting bracket EN IBR Protective current transformers Rated currents: A Secondary: 1 A / 5 A : Ø 44 mm : 50 x / 2 x 40 x mm Dimensions: 90 x 1 x 40 mm IBR Technical Features, Executions current A Rated burdens VA.../5A.../5A 5P5 P5 5P5 P ,25 1,25 1,25 1, ,25 1,25 2,5 2, ,5 2,5 2,5 2, ,5 2,5 3,75 3, ,5 2,5 3,75 3, ,5 2, ,25 1,25 3,75 3, ,25 1, Included in delivery: Primary fixing device Accesories (see page 5/53): Mounting feet / snap on mounting bracket EN /16

21 PROTECTIVE CURRENT TRANSFORMERS CLASSIC LINE IBR/1 Protective current transformers Rated currents: A Secondary: 1 A / 5 A : Ø 44 mm : 60 x / 2 x 50 x mm Dimensions: 90 x 1 x 40 mm IBR/1 Technical Features, Executions current A Rated burdens VA.../5A.../5A 5P5 P5 5P5 P ,25 1,25 1,25 1, ,25 1,25 2,5 2, ,5 2,5 2,5 2, ,5 2,5 3,75 3, ,5 2,5 3,75 3, ,5 2, ,25 1,25 3,75 3, ,25 1, Included in delivery: Primary fixing device Accesories (see page 5/53): Mounting feet / snap on mounting bracket EN IER Protective current transformers Rated currents: A Secondary: 1 A / 5 A : Ø 50 mm : 80 x / 2 x 60 x mm Dimensions: 133 x 5 x 46 mm IER/1/2/3 Technical Features, Executions Rated burdens VA (.../5A,.../1A) current A 5P P 5P5 P ,25 2,5 2, ,25 1,25 3,75 3, ,25 1, ,5 2,5 7,5 7, ,25 1, ,5 2,5 7,5 7, ,25 1,25 7,5 7,5 00 2,5 2, ,5 3, Included in delivery: Primary fixing device (except EIR/1) IER/1 /2 /3 Protective current transformers Rated currents: A Secondary: 1 A / 5 A : : Dimensions: Ø 80 mm (IER/1) 3x 60 x (IER/2) / 2x 80 x mm (IER/3) 133 x 5 x 46 mm IER/3 5/17

22 PROTECTIVE CURRENT TRANSFORMERS CLASSIC LINE IRP Protective current transformers Rated currents: A Secondary: 1 A / 5 A : 0 X 20 mm Dimensions: 95 x 190 x 41 mm IRP Technical Features, Execu Rated burdens VA (.../5A,.../1A) current A 5P P 5P5 P ,25 1,25 7,5 7, ,25 2,5 7,5 7,5 00 2,5 2, ,75 3, ,5 7, Included in delivery: Primary fixing device On request: Secondary terminals on the lenght side oif the current transformer. IRM Protective current transformers Rated currents: A Secondary: 1 A / 5 A : 0 x 30 mm Dimensions: 1 x 205 x 46 mm IRM Technical Features, Executions Rated burdens VA (.../5A,.../1A) current A 5P P 5P5 P5 00 3,75 3, , ,5 7, Included in delivery: Primary fixing device On request: Secondary terminals on the lenght side oif the current transformer. 5/18

23 CURRENT TRANSFORMERS SERIE AST AST Current transformers line Technical comments Modern design, versatility and greater safety are the distinctive features of the new ASTLine. In developing we have moreover retained our reliable CELSA secondary terminal. Greater safety The joining point where the two halves of the housing meet inside the primary bar opening is crucial to safety. Quite in accordance with CELSA s motto safety is built into our products the two halves of the housing are not aligned with a butt joint, instead they are made to overlap in the new ASTLine. Versatility Current transformers are frequently secured with the help of a lug through which a clamping screw fits onto the primary bar. You must have noticed what a nuisance this lug can be, for instance when you want to install the CT behind fuse switch disconnectors, fuse trips or between bar overlaps and exits. The new current transformer of the CELSA ASTLine have their own solution to this problem. The conventional fixing device has been designed with a formlocking guide so that if necessary it can simply be pulled out. Insulated protective caps for primary fixing bolts To protect against unintentional contact the bolts of the primary fixing devices can be covered by protective insulation caps. These should be pressed only on the already fastened bolts, not between bolts and bars. Extended secondary terminal cover When using the CT as a tube type CT you may wish to increase the air gaps and creepage distances between secondary terminals and primary bars. You can do so by adding protective terminal covers over the CT openings on the front and back as shown. 5/19

24 CURRENT TRANSFORMERS SERIE AST General Features Secondary terminal openings. The connection of secondary wire leads to their corresponding terminals is normally done by sliding them into the rectangular openings on the front or the back. If this way of connection is prohibited for instance due to blocking when mounted right behind a line of fuses the secondary wire leads equipped with clamps can also be introduced into the lateral slots for secondary terminal connection as shown Of course all AST current transformers comply with EN 60044, DIN VDE 0414, VDE 00, DIN as well as the regulations VBG 4, VDE 06 part 0.. General Mechanical Feature unbreakable plastic casing, polyamide difficult to inflame, according to UL 94 V0 and selfextinguishing nickelplated secondary terminals with plus minus screws (2 Nm) integrated secondary terminal caps The CELSA Secondary terminal In this clamping system pressure is transmitted by means of a nut (pad) to the ends of the conductor (lift principle). The conductor is therefore loaded only under pressure and cannot be demaged by rotating components. When opened, there are two clamping spaces of 2.5mm x 4mm each in crosssection. Thanks to our clamping system the ends of the conductors are clamped over a wide area which ensures lower contact resistance. Pressure forces of several hundret Newtons are reached. In this way conductors even with multiple, fine and extremely fine wires are so well compressed that no harmful gases can penetrate to cause corrosion. It therefore provides an extremely longlasting connection even in aggressive industrial environment. The plusminus slot of the M5 (2 Nm) screws allows easy of handling. At the ASTLine both, screws and nuts are designed in such a way to prevent unintentional loosening. The secondary terminals are made of brass with nickel as a double terminal construction. This double construction permits a very easy short circuit of the current transformer during operation in order to carry out work on the secondary circuit. General Electrical Features rated frequency 5060Hz (other frequencies on request) class of insulation E (other classes on request) rated shorttime thermal current Ith = 60. IN nominal surge current Idyn = 2.5. Ith, minimum 0kA at all window type c.t. s highest voltage for equipment Um = 0,72kV (other voltages on request) rated powerfrequency withstand voltage 4kV/1min (other voltages on request) instrument security factor FS5 or FS All CELSA current transformers are dimensioned (exceptionell some marked types) in accordance with VDE 0414 for a rated continuous thermal current of I D = 1,2 I N. Included in delivery: secondary therminal covers primary fixing device mounting feet Accesories: costeffective snapon mounting brackets out of highly reinforced fibre glass macrolon for snapping on a profile mounting bar according to EN and DIN copper tubes in various sizes for using a current transformer as a tube type current transformer copper primary bars in various sizes insulated protective caps for primary fixing bolts protective terminal cover to increase the air gaps and creepage distances if using the CT as tube type CT. 5/20

25 CURRENT TRANSFORMERS SERIE AST ASTR21 WINDOW OR TUBE TYPE CURRENT TRANSFORMERS Special designs (on request): nonstandard primary and secondary rated currents compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/37) Ø 21 mm With ETLCertification (USA, Canada) Type: CTR 21 ASTR21 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ) other values on request Included in delivery: 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN copper tube (d o = 21mm, d i = 8.5 mm, L 1) = 32mm) for using the CT as tube type current transformer protective terminal cover to increase the air gaps and creepage distances if using the CT as tube type CT 5/21

26 CURRENT TRANSFORMERS SERIE AST AST3 Special designs (on request): nonstandard primary and secondary rated currents Compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/37) Ø 28 mm 30 x mm 20 x 20 mm With ETLCertification (USA, Canada) Type: CT 30 AST3 Technical Features, Executions current 1) A sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA , ,25 2) , , ,5 91 1, , , ,5 52 2, , , , , , , , , ,5 70 7, ) other values on request 2) 3 Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts copper tube (d o = 28mm, d i = 12.5mm, L 1) = 32mm) for using the CT as tube type current transformer protective terminal cover to increase the air gaps and creepage distances if using the CT as tube type CT 5/22

27 CURRENT TRANSFORMERS SERIE AST AST412.6 Special designs (on request): nonstandard primary and secondary rated currents compoundfilled with cast resin Ø 33 mm 40 x 12 mm 2 x 30 x mm With ETLCertification (USA, Canada) Type: CT 40.6 AST412.6 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , ,5 13 2, , , , , , , , , , , , , , , , , ) other values on request Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/23

28 CURRENT TRANSFORMERS SERIE AST AST412 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/38) Ø 33 mm 40 x 13 mm 2 x 30 x mm With ETLCertification (USA, Canada) Type: CT 40 AST412 Technical Features, Executions current 1) A sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA ,25 2) ,25 2) ,25 2) ,25 2) , , , , ,5 10 2, , , , , ,5 17 2, , , , , , , , , , , ) other values on request 2) 3 Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/24

29 CURRENT TRANSFORMERS SERIE AST AST512.7 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) Ø 42 mm 50 x 12 mm 2 x 40 x mm With ETLCertification (USA, Canada) Type: CT 50.7 AST512.7 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ) other values on request Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts copper tube (d o = 43.7mm, d i = 14.2 mm, L 1) = 32mm) for using the CT as tube type current transformer protective terminal cover to increase the air gaps and creepage distances if using the CT as tube type CT 5/25

30 CURRENT TRANSFORMERS SERIE AST AST512 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/38) Ø 42 mm 50 x 12 mm 2 x 40 x mm With ETLCertification (USA, Canada) Type: CT 50 AST512 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , , , , , ) other values on request Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts copper tube (d o = 43.7mm, d i = 14.2 mm, L 1) = 32mm) for using the CT as tube type current transformer protective terminal cover to increase the air gaps and creepage distances if using the CT as tube type CT 5/26

31 CURRENT TRANSFORMERS SERIE AST AST6.8 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) Ø 52 mm 60 x mm 2 x 50 x mm 40 x 40 mm With ETLCertification (USA, Canada) Type: CT 60.8 AST6.8 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , , , , , , , , , , , , , , , ) other values on request Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/27

32 CURRENT TRANSFORMERS SERIE AST AST6 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/39) Ø 53 mm 63 x mm 2 x 50 x mm 40 x 40 mm With ETLCertification (USA, Canada) Type: CT 60 AST6 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , , ) other values on request Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/28

33 CURRENT TRANSFORMERS SERIE AST AST640 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV ) certificable design tariff metering (see page 5/39) Ø 61 mm 60 x 40 mm 50 x 50 mm With ETLCertification (USA, Canada) Type: CT 6040 AST640 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , , , , , , , , , , , , , ) other values on request Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/29

34 CURRENT TRANSFORMERS SERIE AST AST8 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/40) Ø 61 mm 80 x mm 2 x 60 x mm 3 x 50 x mm With ETLCertification (USA, Canada) Type: CT 80 AST8 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , ) other values on request Included in delivery: 1 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/30

35 CURRENT TRANSFORMERS SERIE AST AST830 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/40) Ø 70 mm 2 x 80 x mm 60 x 60 mm With ETLCertification (USA, Canada) Type: CT 8030 AST830 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , , , , , , , , , ) other values on request Included in delivery: 2 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/31

36 CURRENT TRANSFORMERS SERIE AST AST30 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/41) Ø 85 mm 2 x 0 x mm 80 x 64 mm With ETLCertification (USA, Canada) Type: CT 030 AST30 Technical Features, Executions current 1) A 0.5 sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA ) other values on request Included in delivery: 2 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/32

37 CURRENT TRANSFORMERS SERIE AST AST56 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/41) 3 x 0 x 12 mm With ETLCertification (USA, Canada) Type: CT 055 AST56 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA ) other values on request Included in delivery: 2 pc. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/33

38 CURRENT TRANSFORMERS SERIE AST AST1234 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV) certificable design tariff metering (see page 5/42) Ø 96 mm 2 x 120 x mm 3 x 0 x mm 80 x 80 mm With ETLCertification (USA, Canada) Type: CT AST1234 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA ) other values on request Included in delivery: 2 pcs. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/34

39 CURRENT TRANSFORMERS SERIE AST AST1272 Special designs (on request): nonstandard primary and secondary rated currents secondary tabs (2 or 3 changeover functions) compoundfilled with cast resin max. service voltage (1,2kV ) 4 x 120 x mm With ETLCertification (USA, Canada) Type: CT AST1272 Technical Features, Executions current 1) A sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA sec. 1 A Rated burdens VA sec. 5 A Rated burdens VA ) other values on request Included in delivery: 2 pcs. primary fixing device 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN insulated protective capsfor primary fixing bolts 5/35

40 CURRENT TRANSFORMERS SERIE AST WST40 WICKELCURRENT TRANSFORMERS Special designs (on request): nonstandard primary and secondary rated currents compoundfilled with cast resin WST40 Technical Features, Executions current 1) A sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA sec. 1 A sec. 5 A Rated burdens VA Rated burdens VA , , , ) other values on request Included in delivery: 2 pcs. secondary terminal covers (yellow caps) 2 pcs. mounting feet Accesories (see page 5/53): snap on mounting bracket for profile mounting bar to EN /36

41 CERTIFICABLE CURRENT TRANSFORMERS E4R21.3 CERTIFICABLE WINDOW OR TUBE TYPE CURRENT TRANSFORMERS Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Ø 21 mm Accesories see ASTR21 (Page 5/20) E4R21.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , , ) other values on request E6A3.3 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Ø 28 mm 30 x mm 20 x 20 mm Accesories see AST3 (Page 5/21) E6A3.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , , , ) other values on request 5/37

42 CERTIFICABLE CURRENT TRANSFORMERS E7A412.3 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Ø 33 mm 40 x 12 mm 2 x 30 x mm Accesories see AST412 (Page 5/23) E7A412.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , ) other values on request E8A512.3 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Ø 42 mm 50 x 12 mm 2 x 40 x mm Accesories see AST512 (Page 5/25) E8A512.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , , , ) other values on request 5/38

43 CERTIFICABLE CURRENT TRANSFORMERS E9A6.3 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Intermediate size E8A6.3 on request Ø 53 mm 60 x mm 2 x 50 x mm 40 x 40 mm Accesories see AST6 (Page 5/27) E9A6.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , ) other values on request E9A640.3 Special designs (on request): secondary 1A secondary tabs Compoundfilled with cast resin Ø 61 mm 60 x 40 mm 50 x 50 mm Accesories see AST640 (Page 5/29) E9A640.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , ) other values on request 5/39

44 CERTIFICABLE CURRENT TRANSFORMERS EA8.3 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Ø 61 mm 80 x mm 2 x 60 x mm 2 x 50 x mm Accesories see AST8 (Page 5/30) EA8.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , ) other values on request EA830.3 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Ø 70 mm 2 x 80 x mm 60 x 60 mm Accesories see AST830 (Page 5/31) EA830.3 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , , , ) other values on request 5/40

45 CERTIFICABLE CURRENT TRANSFORMERS E13A30.3 Special designs (on request): secondary 1A secondary tabs Ø 85 mm 80 x 64 mm 2 x 0 x mm compoundfilled with cast resin Accesories see AST30 (Page 5/32) E13A30.3 Technical Features, Executions current 1) A Rated burdens VA (max.).../ 5A 0,2 S , ,5 S , ) other values on request E13A56.3 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Accesories see AST56 (Page 5/33) E13A56.3 Technical Features, Executions current 1) A Rated burdens VA (max.).../ 5A 0,2 S , ,5 S , , , ) other values on request 5/41 3 x 0 x 12 mm

46 CERTIFICABLE CURRENT TRANSFORMERS E16A Special designs (on request): secondary 1A secondary tabs Compoundfilled with cast resin Ø 96 mm 2 x 120 x mm 3 x 0 x mm 80 x 80 mm Accesories see AST1234 (Page 5/33) E16A Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , , , ) other values on request EIPA30.5 Special designs (on request): secondary 1A secondary tabs compoundfilled with cast resin Accesories see SMU/I (Page 5/1) Ø 23 mm 30 x mm 25 x 25 mm EIPA30.5 Technical Features, Executions current 1) A ,2 S Rated burdens VA (max.).../ 5A , ,5 S , , , , , , , , , , , , , , ) other values on request 5/42

47 SUMMATION CURRENT TRANSFORMERS SSR Summation current transformers Summation current transformers SSR2 to SSR9 are used to summarize secondary currents of several main c.t.`s in order to measure with one instrument only. The output current again constitutes a standardized quantity. That means the primary currents are not only added but also divided by the number of inputs. If using unequal main c.t.`s the ratio of the lowest primary current to the highest one should not exceed 1:. When ordering in case of unequal main c.t.`s the ratio of each of them has to be specified absolutely. Unused primary connections have to be open circuited as opposed to the short circuiting of secondary connections Dimensions Connections Housing D (SSR2 to SSR4) Housing D (SSR2 to SSR4) Housing D20 (SSR5 to SSR9) Housing D20 (SSR5 to SSR9) 5/43

48 SUMMATION CURRENT TRANSFORMERS SSR Technical Features Electrical Features Hightest voltage equipment: Rated insolation leve: Rated shottime thermal current (I th ): Rated dynamic current (I dyn ): Frecuency range: Internal consumption: Thermal class of insulation: Accuracy class index and burden 0,5 1 Mechanical Features 720 V 4 kv, 1 min. 60 x I N 2.5 x I th 50 60Hz Max. 4 VA E VA VA Housings Of selfextinguishing ABS UL94 V0 Protection degree Fixing Connection Protection degree of connection Weight IP40 Hightest proportion for different ratios of main c.t`s 1: Housing size DINrail DIN EN50022 or screw fastening Nickel plated secondary terminals with plus minus screws IP, with secondary terminal cover = IP20 (option) D = 400g, D20 = 600g SSR2 until SSR4 = D SSR5 until SSR9 = D20 SSR Technical Data, Executions Article identical ratios of main c.t. s Article Nr Article Nr Article different ratios of main c.t. s Article Nr Article Nr SSR2 5+5/5A SSR21 5+5/5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A SSR /5A other values on request SSR Technical Data, Executions Artikel identical ratios of main c.t. s Article Nr Article Nr Artikel different ratios of main c.t. s Article Nr Article Nr SSR2 1+1/1A SSR21 1+1/1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A SSR /1A other values on request 5/44

49 SPLIT CORE CURRENT TRANSFORMERS IAP IAM IAG Split core current Transformer IAG IAM IAP Application Split core current transformers convert an alternating current of high value into a proportional, lower one, which is appropiate to be measured by standard instruments (ammeters, wattmeters, varmeters, power factor meters, relays, measuring transducers...) of rated currents 5 or 1 A. Their split core allows their installation in already existing networks without need to cut the conductors. They are suitable for indoor use in lowvoltage networks, and they are built according to IEC and EN standards. Design features The current transformers can be opened Cases of selfextinguishing polycarbonate UL 94 V0 Double secondary terminals, for short circuiting the secondary winding before opening the measuring circuit Mounting brackets for the panel mounting and fixing clamps for the fixing to the primary bus bar are included Accuracy Our current transformers fulfil the specifications of the accuracy classes 0.5, 1 and 3, for the rated burden indicated in the table (see next page). IAP, IAM, IAG Technical Data Mechanical Data Electrical Features (according to IEC600441) Window: Rated secondary current 5 or 1 A IAP busbar 2x 50x mm, 3x 40x mm or round conductor Ø 40 mm Frecuency range Hz IAM busbar 4x 80x mm or round conductor Ø 80 mm Hightest voltage for equipment 720 V IAG busbar 4x 125x mm or round conductor Ø 80 mm Rated insulation level 3kV, 50Hz 1 min. Rated continuos thermal current 1.2x I N Weight: (depending on primary current) Rated shorttime thermal current (I th ) 60x I N IAP 40 g g Rated dynamic current (I dyn ) 2.5x I th IAM 1190 g g Thermal class of insulation, according to IEC6085 E (120ºC) IAG 1640 g g Dimensions IAP IAM IAG 5/45

50 SPLIT CORE CURRENT TRANSFORMERS IAP IAM IAG Technical Daten, Executions current Article Nr. A sec. 1A IAP IAM IAG Cl. 0,5 Cl. 1 Cl. 3 Article Nr. VA VA VA Cl. 0,5 Cl. 1 Cl. 3 Article Nr. VA VA VA Cl. 0,5 Cl. 1 Cl. 3 VA VA VA , , ,25* 2, , ,25* 3, , ,5* 3, , ,75* 3, ,25* 3, ,75* 7, ,5* 3, * ,75* , , , ,5 7, , , , , , Remark: These current transformers meet the demands for the classes 0.5, 1 and 3 in the same instrument. / * only ammeters IAP IAM IAG Technical Daten, Executions current Article Nr. A sec. 5A IAP IAM IAG Cl. 0,5 Cl. 1 Cl. 3 Article Nr. VA VA VA Cl. 0,5 Cl. 1 Cl. 3 Article Nr. VA VA VA Cl. 0,5 Cl. 1 Cl. 3 VA VA VA , , ,25* 2, , ,25* 3, , ,5* 3, , ,75* 3, ,25* 3, ,75* 7, ,5* 3, * ,75* , , , ,5 7, , , , , , Remark: These current transformers meet the demands for the classes 0.5, 1 and 3 in the same instrument. / * only ammeters 5/46

51 SPLIT CORE CURRENT TRANSFORMERS TC TQ Split core current transformer / sensor Very easy mounting is guaranteed Fast fixation with two UVresistant tie wraps Also in class 1 available for high accurate kwh measurements All TC/TQ.. split core CT s are supplied with colour coded leads TC / TQ Technical Features Application The very compact TQ/ TC are especially designed for connection to digital measurement systems. All TC /TQ are supplied with colour coded leads secondary leads. Correct closing of the current transformer/sensor is guaranteed by a distinct sound of a click. Two UVresistant tyraps are supplied with the current transformer which can be easily mounted around the primary conductor. TC / TQ Technical Data Enviromental conditions Location Operating temperature Relative humidity Protection degree Application conditions Indoor use TQ18B: TC18: TQ27: TQ42: TQ84: ºC to +55ºC 5ºC to +40ºC ºC to +55ºC ºC to +55ºC ºC to +55ºC 5% 85%, non condensing IP20 Standard IEC Rated shorttime thermal current Continuous thermal current (Icth) Rated insulation level Rated frequency of insulation Primäre Fenstermasse Primary window dimensions 60 x ln/1s 0% ln 0,72/3kV 50/60Hz E (120ºC) TQ18B: max. Ø 18mm TC18: max. Ø 18mm TQ 27: max. Ø 28mm TQ42: max. Ø 42mm TQ84: max. 2 x Ø 42mm TC18: 0,5mm 2 flexibel TQ18B/TQ27/TQ42/ TQ84: 1A: L= 3m cabel 0,5mm 2 flexibel 1A: L= 5m cabel 0,5mm 2 flexibel (TQ42) 5A: L= 0,5 m cabel 1,5mm 2 flexibel Type TQ 18B TC 18 TQ 27 TQ 42 TQ 84 TQ42 Article Nr Primary current A Cl. 0,5 2) VA Rated burden 1) Cl.1 2) VA 25 0/1A 0, /1A 0,2 27 0/1A 0, /1A 0,2 53 0/5A /5A /5A 1 Cl.3 VA 01 60/1A 0, /1A 0,2 03 0/1A 0, /1A 0,2 05 0/1A 0, /1A 0, /1A 0, /1A 0, /1A 0, /1A 0,2 400/1A 0, /1A 0, /5A /5A /5A /5A 1 TQ /1A 0, /1A 0, /1A 0, /1A 0, /1A 0, /1A 0, /1A 0, /1A 0, /5A 0, /5A 0, /5A 0, /5A 0, /5A 0, /5A 0, /5A 3) 0,5 1) Burden specified at the end of the secondary leads 2) Accuracy conform IEC , valid from 5 to 20% In 3) Ambient temperature ºC ºC 5/47

52 SPLIT CORE CURRENT TRANSFORMERS Dimensions / Wiring diagrams TC18 TQ18B Wiring diagrams Wiring diagrams Dimensions Dimensions TQ 27 TQ 42 / TQ 84 Wiring diagrams Wiring diagrams Dimensions Dimensions TQ42 TQ84 5/48

53 CURRENT TRANSFORMERS WITH FUSED TERMINAL VST Current Transformer with fused terminal Easy mounting on DIN rail Three in one current transformers/voltage terminal/busbar terminal Available for a three current ranges Including two ampere fuse Saves space and mounting time Funktionsprinzip To measure power, voltage and current values are required from each phase. In common cases there is often less space for measurement transformers and voltage terminals. The new CELSA Power Sensor type VST.. solves this problem by combining three functionalities in one product. This is the busbar terminal, the current transformer and the voltage terminal as well. The fuse is directly mounted on the primary conductor. As result of the short unprotected part of the terminal the reliability is much higher. The CELSA Power Sensor makes it very easy to wire the terminal because of less connections. This reduces mounting costs. Because of reduction of the number of connections the terminal is more reliable than standard terminals. It also decreases mounting space.. VST Technical Data Rated current Burden 1) Type Article Nr. 16/1 A 3 0,1 VA VST /1 A 1 0,2 VA VST /1 A 0,5 0,2 VA VST ) External cabel losses= 0,014 VA/m (2,5 mm²) Dimensions VST General Features General Maximum voltage Insulation voltage Rated current Max. current (AWG 6) Max. current (16mm²) Insulation class Protection degree Ambient temperature Case Suitable for marking 690V, Uimp 6kV 1890V/50Hz 1min. 64A 67A 76A E (max120 ) IP C PA 30% glass filled PHOENIX ZBF5 Screw terminal Philips head DIN 7962H2 Aprobation Terminal According standard Min/Max Wire gauge: Solid wire Stranded wire / AWG Voltage terminal Fuse type Short circuit capability Max. wire gauge Current Transformer According standard Frequency Ith Insulation voltage KEMAKEUR IEC ,5mm2 16mm2 / AWG x25mm (with message) Max 2A SIBA DIN kA@400V/50Hz 1,5mm2 4mm² IEC Hz 60xIn 3kV/50Hz 1min. Connection diagrams 5/49

54 ACCESORIES VOLTAGE MEASUREMENT VSP Voltage taps for bus bas VSPL4 Terminal voltage tap for bus bar with integrated fuse The VSP of insulated busbar terminals let you connect your instruments to live busbars. A fuse holder is an integrated part of this terminal, proving you with protection at the source. The terminal can be installed directly onto the busbar using an insulated Allen key driver. This makes the installation of this unique product a one handed exercise. The fuse holder is mounted directly on the metal that makes contact with the busbar, thereby providing a secure connection with a high short circuit rating. For connection to the Netural bar, the model VSP provides an unfused connection. VSPN16 Terminal voltage tap for bus bar without integrated fuse VSP.. General Features General Maximum voltage Test voltage / spike Max. current Isolation class Fuse type Short circuit rating IP rating 690 V 3 kv/50 Hz / 6 kv A E (max 120 C) 5x25 mm (with indicator) A SIBA DIN V/50 Hz IP20 Ambient temperature C 1) Temperature rise busbar Max. 75 K 1) Busbar connection Allen key size Number 6 Busbar thickness Housing Material terminal Via Allen key bolt M8 Max. mm / min. 4 mm Polyamide (PA6.6) Nickel plated brass 1 )Max. temperature of the busbar: 120º (Sum of the busbar temperature rise and the ambient temperature) VSPL4 VSPN16 VSP... Variants Article Nr. Model Description Colour Connection VSPL4 Fused phase terminal black 1,5 4mm² VSPL16 Unfused phase terminal black 0 16mm² VSPN16 Neutral terminal blue 0 16mm² Set with 3 x VSPL4 and 1 x VSPN16 5/50

55 ACCESORIES VOLTAGE MEASUREMENT VSR6 Voltage taps for round conductors Onehanded and safe tapping of voltage for measurement purposes No tools needed Safe mounting Including 5x25mm, 2A fuse For insulated mm2 conductors, stranded, solid (rigid) wire In existing installations there is rarely a fused terminal available for measurement purposes. This unique tapping clamp allows you to tap a fused voltage from an insulated wire for measurement using one hand and without the need for additional tools. The fuse is mounted directly on the primary conductor, which results in an optimum degree of safety. This unique product is a breakthrough for fast and safe measurement in existing installations This model is obtainable in a fused and non used version. VSR6.. Technical specifications Safety conditions CE Dirrective: Standard: Low voltage directive 2006/95/EC IEC (clamp), IEC 60947(fuse) Environmental conditions Standard IEC :1996 3K3 Operating temperature +5 C +55 C Relative humidity 5% 85%, non condensing Operating height m over NN Protection degree IP20, basic insulation Pollution degree 2 Measurement category CAT III Application conditions Only for suitable for conductors with basic insulation (wire) Insulation material PVC or XLPE Wire diameter 3 5mm (2,5 6mm²) VSRL6R / VSRN6R Rigid wire (Solid, Stranded) Umax 400 V AC Test voltage 3kV / 50 Hz Impulse voltage Imax 2 A Voltage drop < 500m V AC Fuse (VSRL6R) Sec. Lead Usability Torque Storage Temperature Relative humidity Weight Dimensions Material 2A, 450V, F, 70kA, 5x25mm, ceramic (SIBA Part.no ) 1mm² flexible, 50cm, endsleeve Multiple use, max. 24 times Nm 20 C +70 C 5% 85%, non condensing 28 gr. diameter 23mm, height 59mm PA 6.6, UL94 V2 Wiring diagrams: Dimensions: VSR6... Variants Article Nr. Model Cabel dimensions VSRL6R fused, for 2.56mm² rigid (solid, stranded) wire rigid (solid, stranded) wire VSRN6R not fused for 2.56mm² rigid (solid, stranded) wire Set with 3 x VSRN6R and 1 x VSRL6R 5/51

56 ACCESORIES VOLTAGE MEASUREMENT VSR16 Voltage taps for round conductors Onehanded and safe tapping of voltage for measurement purposes No tools needed Safe mounting Including 5x25mm, 2A fuse For insulated 6 16 mm2 conductors, stranded and solid In existing installations there is rarely a fused terminal available for measurement purposes. This unique tapping clamp allows you to tap a fused voltage from an insulated wire for measurement using one hand and without the need for additional tools. The fuse is mounted directly on the primary conductor, which results in an optimum degree of safety. This unique product is a breakthrough for fast and safe measurement in existing installations. VSR16.. Technical specifications Max. voltage Test voltage (casing ground) 400V 3kV / 50Hz Impulse (casingconductor) 6KV 1,2/ 50µs Max. rated current Voltage drop Fusetype phase terminal Short circuit current Protection degree Ambient temperature Suitable for Torque 2A < 500m V AC 5x25mm, 2A (with indicator) Max 2A SIBA DIN V/50Hz IP C PVC and XLPE, stranded and solid conductors 1.5 Nm multiple use 2.0 Nm single use Dimensions: Wiring diagrams: VSR16... Variants Article Nr. Model Cable dimensions VSRL16 616mm² fused neutral terminal VSRN16 616mm² Unfused neutral terminal Set with 3 x VSRN16 and 1 x VSRL16 5/52

57 ACCESORIES CURRENT TRANSFORMERS Snap on mounting (DIN rail) For installation on DIN rails Available for the following Curren transformers Article Nr. IB Series Article Nr. AST Series IBA, IBP AST IB, IB WST IBG, IBG SMU IBO SMU/I Mounting feet For installation on mounting feet Available for the following Curren transformers Article Nr. IB Series Article Nr. AST Series IBA, IBP AST IB, IB50, IBG, IBG WST IBR, IBR/1, IAP, IAM, IAG SMK, SMK/I IBO SMG, SMG/I Copper tubes / CU Sleeve Available sizes IB Series IBD1 > Width: 60 mm (da = 20x20 mm, di = 12,5 mm) IBD2 > Width: 40 mm (da = 20x20 mm, di = 12,5 mm) AST Series CUSleeve > Width: 32 mm (da = 28 mm, di = 12,5 mm CUSleeve > Width: 32 mm (da = 42 mm, di = 12,5 mm) 5/53

CURRENT TRANSFORMER - AST line

CURRENT TRANSFORMER - AST line ST - C.T.`s line Technical comments Modern design, versatility and increased safety are the distinctive features of the new STline. In developing the new series we have moreover retained our reliable CELS

More information

Snap-in covers I Voltage taps

Snap-in covers I Voltage taps ACCESSORIES Accessories for analogue instruments, current transformers, switchboards, voltage taps for busbars and round conductors. Snap-in covers I Voltage taps Voltage taps page 10/1 10 For analogue

More information

Current transformers. Current transformers

Current transformers. Current transformers Current transformers Current transformers Moulded case current transformer Moulded case CT, class 1 and 0.5 / 5 A Increased reliability Both halves of the housing overlap rather than butting up against

More information

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...

More information

Technical information

Technical information Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary

More information

PHOENIX CONTACT

PHOENIX CONTACT Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers

More information

Chapter 06 Accessories ACCESSORIES

Chapter 06 Accessories ACCESSORIES ccessories CCESSORIES 57 Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for the UMG measurement input Use in IT networks

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Single-phase CT current transformers Cat. Nos :

Single-phase CT current transformers Cat. Nos : Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type

More information

KOLMA and IHDA Indoor Type Cable Current Transformers. Catalogue. Catalogue KOLMA 1 GB Medium Voltage. ABB Transmit KKOLMA 1 GB

KOLMA and IHDA Indoor Type Cable Current Transformers. Catalogue. Catalogue KOLMA 1 GB Medium Voltage. ABB Transmit KKOLMA 1 GB Catalogue KOLMA and IHDA Indoor Type Cable Current Transformers Catalogue KOLMA 1 GB 99-05 Medium Voltage ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description...

More information

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications: CTB 31.35 Plug-in current transformer Dimensions: Primary conductor 1: 30x10 mm Primary conductor 2: 25x12 mm Primary conductor 3: 20x20 mm Round conductor: 26 mm Transformer width: 60 mm Transformer height:

More information

Current accuracy class. Sensor principles

Current accuracy class. Sensor principles Indoor Combi Sensor 12, 17.5 and 25 kv 1250 A and 3200 A KEVCD Highest voltage for equipment kv 12.24 Rated continuous primary current A 1250.3200 Rated transformation ratio for current measurement, K

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

SIGMA SERIES DE METER

SIGMA SERIES DE METER SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar Pressure Transmitter Type FM40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The measuring device for the transmitter

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Filters and Fans Fuse Switch Disconnectors XNH Thermostats Terminals Catalogue 2017 Electrical Cabinet Heating Fuse

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Pressure Transmitter JUMO dtrans p30 Type

Pressure Transmitter JUMO dtrans p30 Type Data Sheet 40466 Page 1/6 Pressure Transmitter JUMO dtrans p0 Type 40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The

More information

Basic Series Accessories Low Voltage Current Transformer Class 1

Basic Series Accessories Low Voltage Current Transformer Class 1 Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating

More information

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description Capacitive sensor, Foreground Suppression Main features Compact housing Supply voltage: 10 to 30 VDC Output: 100 ma, NPN or PNP preset Make or break switching function LED indication for output and power

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

Combined instrument transformers

Combined instrument transformers Combined instrument transformers Outdoor operation SF 6 -gas insulated EJGF (245 550) kv General description Type EJGF combined transformers are used in high-voltage substations within the 245 550 kv range.

More information

Protection and control VIP30, VIP35. Relays technical manual

Protection and control VIP30, VIP35. Relays technical manual Protection and control VIP30, VIP35 Relays technical manual contents 1. presentation of the VIP30 and VIP35...3 2. use and settings...4 3. sensors and operating ranges... 4. connection scheme...9 5. assembly

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4

1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4 T-LINE 1. Table of Contents Page 1. Table for contents 2 2. Description Current transformers type HF 3 3. Product Overview 4 4. Measuring accuracy VA Burden 5 5. Survey chart 0,5 1 3, type HF3A, HF3B and

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS POWER FACTOR METERS - LF 72 / LF 96 Analogue Meters www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Scheda prodotto Relè Series B

Scheda prodotto Relè Series B Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the : 55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

XM1 - Motor protection relay

XM1 - Motor protection relay XM1 - Motor protection relay Contents 1 Applications and features 1 Applications and features 2 Design 3 Working principle 3.1 Overload protection 3.2 Stalling protection 3.3 Earth fault protection 3.4

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

JUMO MIDAS Pressure transmitter

JUMO MIDAS Pressure transmitter Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped

More information

Position switches FC series

Position switches FC series A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls 11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826, S26 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826 Series Dual changeover switches with positive

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES) MODEL N 4." I.D. PAGE No 1-30 TERMINAL OPTION LEAD WIRE OPTION 6.75 SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.75 1.36 1.16 5.75 7.00 0. x 0.50 SLOT (2 PLACES) UL 1015 #16

More information

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL

More information

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the

More information

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations Three-phase isolating transformers for the supply of three-phase loads in medical locations DS0107_D00105_00_D_XXEN/05.2015 Three-phase isolating transformers for the supply of three-phase loads in medical

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Pressure transmitter for elevated media temperatures

Pressure transmitter for elevated media temperatures Data Sheet 402050 Page 1/7 JUMO dtrans p31 Pressure transmitter for elevated media temperatures General application Pressure transmitters are used for measuring the relative (gauge) and absolute pressures

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A. LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2

More information

Technical Data Sheet Sigma Series DE Meter

Technical Data Sheet Sigma Series DE Meter Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S MOTORSAVER MODEL 460 BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

More information

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system Premium PFC Capacitors General capacitors in cylindrical aluminum cases have been designed for power factor correction in low-voltage plant. Loads like motors and transformers consume active power as well

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting.

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

Single foot switches PX and PA series

Single foot switches PX and PA series A Single foot switches PX and PA series Selection diagram CARRYING ROD See page /10 ADDITIONAL METAL PROTECTION OPEN PROTECTIONS CLOSED PROTECTIONS PA PA 2 CONTACT BLOCKS COMBINATIONS 01 02 1NO+1NC snap

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/24DC/20 DC/DC converter with SFB Technology, primaryswitched, input: 24 V DC, output: 24 V DC, output current: 20 A Data sheet 104791_en_01 PHOENIX CONTACT 20130405 1 Description QUINT DC/DC converter maximum

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Page 1 of 2 Ref: IW012346 Rev 4 July 03 Indicators Saxon & Fiesta Series Products Covered 012-**, 013-**, 014-** & 016-** Installation The product should be panel mounted using the mounting kit provided.

More information