Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB
|
|
- Bertram Hudson
- 5 years ago
- Views:
Transcription
1 Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Medium Voltage 1
2 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description... 3 Technical data and ordering information Test voltages... 4 Secondary wiring... 4 Short circuit strength... 4 Environment... 5 Ordering data... 5 Enquiry and order specifications... 5 Order example... 5 Use at high altitudes... 6 Medium and long size kv... 7 Medium and long size 4 kv Medium size 36 kv... 16
3 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Description The current transformer series is built according the dimension standard DIN 4600, Narrow. The standard giving dimensions for only the herein called medium size also has developed a longer version to provide more core space. The series of transformers covers the current range Amps for 1 36 kv. The 13.8 kv and 17.5 kv versions have the same dimensions as the 1 kv version. transformers are available as single ratio, primary reconnectible double ratio and secondary reconnectible double ratio (or multiratio) types. 3
4 Indoor Current Transformers Technical data and ordering information Rated primary currents: Max A primary reconnectable and 300 A single ratio. Maximum rated continuous thermal current is 3600 A Secondary current: 5 A, 1 A. Others on request. Accuracy classes: 0., 0.5, 1.0 for measuring 5P10, 5P15, 5P0, 10P10, 10P15, 10P0 for protection Others on request Standards: IEC 185, IEC 44-1, VDE Others on request. Frequencies: 50 Hz, 60 Hz, others on request Test voltages Highest system voltage Power-frequency test, 1 min. Impulse withstand voltage (peak) 1 kv 13.8 kv 17.5 kv 4 kv 36 kv Short circuit strength Maximum short circuit values (type tested): Ith Idyn ka 3s, 70 ka 1s 70 ka/1 s 40 ka 3 s 31.5 ka 1 s 40 ka 3s 175 ka 175 ka 15 ka 80 ka 175 ka Ipn/A Secondary wiring 4 The terminal box is metal with plastic cover and provided with two detachable threaded inserts, size Pg. 16. Degree of protection is IP 30. The terminals are provided with M5 screws for the termination of the secondary wiring and with throughgoing holes for direct earthing of the secondary circuit by M6 screws. 6 terminals can be supplied with this construction. Maximum 11 terminals with earthing bridges can be mounted when more than 6 terminals are required. Of these, 9 pcs may be used as core secondary terminals. The terminal cover is sealable.
5 Indoor Current Transformers Technical data and ordering information Cantilever strength: 5 kn Environment The ambient temperature range is from 5 o C to 40 o C (IEC recommendations). The transformers must be protected against unusually heavy deposits of dust or similar pollution, as well as against direct sunshine. Ordering data For core tables and order information please see separate price list. Enquiry and order specifications Quantity System voltage Insulation level Frequency Short-time currents Ith (time) and Idyn Rated primary and secondary currents, extended current rating Rated burden and accuracy class for each core Electrical standard Ambient temperature if other than IEC ( o C) Special requirements, if any (polarity, tropical version, high altitude etc.) Test report, if required, language specified Order example 33 pcs 4C41 Un = 0 kv 4 / 50 / 15 kv 50 Hz 5 ka 1s / 63 ka 750 / 5 / 5 A, ext. 10 core 1: cl. 0,5 Fs 10, 10 VA core : cl. 5P10, 5 VA IEC 185 Reversed polarity (P at the end with the sec. terminals) Test report needed, in english 5
6 Indoor Current Transformers Technical data and ordering information Use at high altitudes In mountaineous areas the height above sea level may be higher than the height specified in the IEC standard as design criteria (= 1000 m). The thin air at high altitudes affects the cooling of the transformers as well as the required creepage free air distance to earth and between phases. The manufacturer should be consulted in such cases. The problem with creepage and free air distance can be solved by choosing transformer type designed for higher voltages. The requirement for impulse test voltge (BIL-level) should preferably NOT be higher than normal for the service voltage used as this may have a negative effect on the available output from the secondaries. The transformer specification can in such a case be for example: Service voltage Test voltages 4 D 17.5 kv 38 kv 1 min. / 95 kv impulse The transformer type 17.5 D would have been suitable if used below 1000 m. Permissable torques for screw connections Strenght class for the screws is 8.8. The length of the screw within the nut part should be at least 1.4 x screw diameter. Screw Max. torque Min. torque Nm Nm M M M
7 Medium and long size kv Medium size I pn < 150 A I max.cont. = 1500 A $ C $ H!! Long size I pn < 150 A I max.cont. = 1500 A 3 1! Weight ~ 0 kg 1 A A A 1 1 C C C 1 1 E E E 1!! $! C $ 4 Weight ~ 31 kg 1 A A A 41 1 C C C 41 1 E E E 41 1 G G G 41 7
8 Medium and long size kv Medium size I pn < A I max.cont. = 100 A!! $ $ C $ C $ H Long size I pn < A I max.cont. = 100 A 4 =! Weight ~ 0 kg 1 B B B 1 1 D D D 1 1 F F F 1! $! = > = > =! > > $ C $ C $ H Weight ~ 31 kg 1 B B B 41 1 D D D 41 1 F F F 41 1 H H H 41 8
9 Medium and long size kv Medium size I pn < 150 A I max.cont. = 1500 A 7 Weight ~ 9 kg 1 AA AA AA 1 1 CA CA CA 1 1 EA EA EA 1 Long size! I pn < 150 A I max.cont. = 1500 A $ ' $ C $! $! C $! $ H A G K A I J! $! 15 H A G K A I J!! Weight ~ 40 kg 1 AA AA AA 41 1 CA CA CA 41 1 EA EA EA 41 1 GA GA GA 41 9
10 Medium and long size kv Medium size I pn < A I max.cont. = 100 A 8 Weight ~ 9 kg 1 BA BA BA 1 1 DA DA DA 1 1 FA FA FA 1 Long size I pn < A I max.cont. = 100 A! $ ' $ C $! = 16 > = > $ $! C $! $ = > =! >! Weight ~ 40 kg 1 BA BA BA 41 1 DA DA DA 41 1 FA FA FA 41 1 HA HA HA 41 10
11 Medium and long size kv Medium size I pn < 300 A $ I max.cont. = 300 A C $ H!! Long size I pn < 300 A I max.cont. = 300 A 5 6!!! $! C $ H Weight ~ 6 kg 1 P P P 1 1 R R R 1 1 S S S 1 Weight ~ 37 kg 1 P P P 41 1 R R R 41 1 S S S 41 1 T T T 41 11
12 Medium and long size kv Medium size I pn < 300 A I max.cont. = 3600 A 64 Weight ~ 30 kg 1 K K K 1 1 L L L 1 1 M M M 1 Long size! I pn < 300A I max.cont. = 3600A $ ' $ C $! N $ $! C $! N J EA B $! 65! Weight ~ 41 kg 1 K K K 41 1 L L L 41 1 M M M 41 1 N N N 41 1
13 Medium and long size 4 kv Medium size I pn < 150 A I max.cont. = 1500 A Long size I pn < 150 A I max.cont. = 1500 A 11 9! $! '! $ C $ C $ H $ C $ H! '! Weight ~ 9 kg 4 A 1 4 C 1 4 E 1 Weight ~ 4 kg 4 A 41 4 E 41 4 C 41 4 G 41 13
14 Medium and long size 4 kv Medium size I pn < A I max.cont. = 100 A Long size I pn < A I max.cont. = 1500 A 1 10 '! $! $ $ C $ C $ H! = = > = '! > = > >! $ C $ C $ H Weight ~ 9 kg 4 B 1 4 D 1 4 F 1 Weight ~ 4 kg 4 B 41 4 D 41 4 F 41 4 H 41 14
15 Medium and long size 4 kv Medium size I pn < 300 A I max.cont. = 3600 A $! C $ H 13 '! Weight ~ 33 kg 4 K 1 4 L 1 4 M 1 Long size I pn > 300 A I max.cont. = 3600 A! $ C $ H! 14 '! Weight ~ 46 kg 4 K 41 4 L 41 4 M 41 4 N 41 15
16 Medium size 36 kv Narrow body I pn < 150 A I max.cont. = 1500 A terminals required (max. 15) Weight ~ 5 kg A C E G 41 I pn < 150 A I max.cont. = 1500 A terminals required (max. 15) '!!!! $! ' '! $! Weight ~ 7 kg 0 '! 36 AA CA EA GA 41 16
17 Medium size 36 kv Narrow body I pn < A I max.cont. = 100 A! terminals required (max. 15) = ' Weight ~ 5 kg = > 19 = >!! $ '! 36 B D F H 41 I pn < A I max.cont. = 100 A!! $! terminals required (max. 15) = > = > ' Weight ~ 7 kg 1 '! 36 BA DA FA HA 41 17
18 Medium size 36 kv Medium size I pn < 3000 A!! I max.cont. = 3000 A $! '! ' terminals required (max. 15) Weight ~ 7 kg 36 K L M N 41 18
19 19
20 97-1 Oy MV Systems Division Instrument Transformers P.O. Box 613, FIN Vaasa, Finland Phone Telefax Waasa Graphics Oy 3000,
KOLMA and IHDA Indoor Type Cable Current Transformers. Catalogue. Catalogue KOLMA 1 GB Medium Voltage. ABB Transmit KKOLMA 1 GB
Catalogue KOLMA and IHDA Indoor Type Cable Current Transformers Catalogue KOLMA 1 GB 99-05 Medium Voltage ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description...
More informationMedium voltage products. KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance
Medium voltage products KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance Instructions for installation, use and maintenance for the KEVCD A combined current
More informationChange-over Disconnectors HUVS Range 12kV (630 to 6300Amp)
Changeover switches 7.2kV to 40.5kV For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances
More informationIndoor instrument transformers Current transformers Voltage transformers
Medium Voltage Distribution Indoor instrument transformers Current transformers Voltage transformers Catalogue 2008 Selection guide Technical description DE52454 Current transformers (CT) meet standard
More informationCurrent sensor. Instructions for installation, use and maintenance. Type KECR 17,5 AC1 ABB
Current sensor Instructions for installation, use and maintenance Type KECR 17,5 AC1 ABB Current sensor Instructions for installation, use and maintenance Type KECR 17,5 AC1 Sensors are new solutions for
More informationChange-over Disconnectors HUVS Range 36kV (630 to 6300Amp)
Changeover switches 7.2kV to 40.5kV For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationPORCELAIN INSULATORS
Solid Core Station Post Insulator PORCELAIN INSULATORS It is an insulator of generally columnar shape, and it consists of one post insulator unit or an assembly of such units and is intended to give rigid
More informationMEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers
MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationPowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.
PowerIT PowerIT Indoor Voltage Transformer Fuses, WBP Outdoor Voltage Transformer Fuses, BRT Catalogue 1YMB612070-en Industrial IT enabled TM 1. FEATURES Unlimited breaking capacity Short circuit current
More informationFuse switch disconnectors
SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED
More informationKECA 80 C85 Current Sensor Instructions for installation, use and maintenance
Medium Voltage Products KECA 80 C85 Current Sensor Instructions for installation, use and maintenance 1. Operating conditions 2 2. Technical details 2 3. Instructions for installation 3 Safety instruction
More informationPHOENIX CONTACT
Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationCURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)
MODEL N 4." I.D. PAGE No 1-30 TERMINAL OPTION LEAD WIRE OPTION 6.75 SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.75 1.36 1.16 5.75 7.00 0. x 0.50 SLOT (2 PLACES) UL 1015 #16
More informationMEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 80 D85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 D85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2
More informationMEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 80 C85 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C85 CURRENT SENSOR INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope of Contents 2
More informationCombined instrument transformers
Combined instrument transformers Outdoor operation SF 6 -gas insulated EJGF (245 550) kv General description Type EJGF combined transformers are used in high-voltage substations within the 245 550 kv range.
More informationThermal-Magnetic Circuit Breaker 2210-S291-P9M A
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact
More informationMEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance
MEDIUM VOLTAGE PRODUCT KECA 250 B1 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C184; KECA 80 C216 CURRENT SENSORS INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope
More informationMedium Voltage Products. KEVA 24 B20; KEVA 24 B21 Voltage Sensors Instructions for installation, use and maintenance
Medium Voltage Products KEVA 24 B20; KEVA 24 B21 Voltage Sensors Instructions for installation, use and maintenance Instructions for installation, use and maintenance for the KEVA 24 B20 and KEVA 24 B21
More informationDisconnectors MF range (0,5 to 3000 Hz) (1250 to Amp)
High Frequency Disconnectors For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness
More information1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide
1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationSolenoid coil for control in potentially explosive areas Type BZ
Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used
More informationenergy management systems Current Transformers
energy management systems 05 Current Transformers CURRENT TRANSFORMERS Current transformers with analogue output page 5/1 Busbars page 5/5 Current transformers ic Line page 5/6 Protective current transformers
More informationZinc Oxide Surge Arrester EXLIM R
Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy
More informationCombined instrument transformers
Combined instrument transformers Outdoor operation Oil-paper insulated EJOF (24 170) kv General description Combined instrument transformers type EJOF are used in high voltage networks within the 24 170
More informationCurrent accuracy class. Sensor principles
Indoor Combi Sensor 12, 17.5 and 25 kv 1250 A and 3200 A KEVCD Highest voltage for equipment kv 12.24 Rated continuous primary current A 1250.3200 Rated transformation ratio for current measurement, K
More informationCurrent transformers. Current transformers
Current transformers Current transformers Moulded case current transformer Moulded case CT, class 1 and 0.5 / 5 A Increased reliability Both halves of the housing overlap rather than butting up against
More informationAC/DC Arc Furnace and Ladle Furnace Transformers
AC/DC Arc Furnace and Ladle Furnace Transformers Specification parameter Specify the requirements for 1. Environmental condition and standards Applicable standard Electrical standard Mechanical standard
More informationATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A
Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to
More informationCombined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications
4-O 1/15 Combined Current and Voltage Instrument Transformer CVS-P-4-O Technical Specifications Rev. Date Revision Description Prepared by Checked by Approved by 0 3/10/15 First Issue E. Scala L. Peretto
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationشركة كهرباء محافظة القدس المساهمة المحدودة
Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories
More informationBasic Series Accessories Low Voltage Current Transformer Class 1
Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating
More informationLow Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201
Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationSingle-phase CT current transformers Cat. Nos :
Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type
More informationHigh Performance Thermal Circuit Breaker
High Performance Thermal Circuit Breaker 43-... Description Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationIndoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A
Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.
More informationBHARAT HEAVY ELECTRICALS LIMITED, JHANSI
BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause
More informationMBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:
CTB 31.35 Plug-in current transformer Dimensions: Primary conductor 1: 30x10 mm Primary conductor 2: 25x12 mm Primary conductor 3: 20x20 mm Round conductor: 26 mm Transformer width: 60 mm Transformer height:
More informationDBM Range 1500VDC (13,5kA to 20kA)
Load Break Switches For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time on-load disconnectors.these devices offer high performances and robustness for
More information3TM Vacuum Contactors
Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents
More informationTransformer bushings, type GOH. Technical guide
Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More information2. INDUCTIVE VOLTAGE TRANSFORMERS Dry and oil-paper insulation
2. INDUCTIVE VOLTGE TRNSFORMERS Dry and oil-paper insulation 12 Instrument transformers Outdoor medium voltage 2. INDUCTIVE VOLTGE TRNSFORMERS > Dry and oil-paper insulation INTRODUCTION Inductive voltage
More informationSwitches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes
Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationResin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide
1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationBUSHINGS: GENERAL INFORMATION
BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency
More informationPROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise
PROTECTION AND CONNECTION ABB Compact ATS Compact without compromise 2 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E ABB ARTICLE COMPACT OR CHAPTER ATS COMPACT TITLE WITHOUT COMPROMISE
More informationSNAP ACTION SWITCHES type SAS-00, SAS-03
EN 60947-5- SNAP ACTION SWITCHES type SAS-00, SAS-03 SAS 00 and 03 Series snap-action switches have one NO and one NC contacts. The change of the switching position is realized by the mechanism, which
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationDisconnectors FA range 750VDC 250 to 2000Amp
750VDC On Board Disconnectors Switch For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances
More information11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls
11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the
More informationDisconnectors FA range 1500VDC 250 to 2000Amp
Disconnectors FA range 1500VDC 250 to 2000Amp ON BOARD DISCONNECTOR SWITCH 1500VDC ON BOARD DISCONNECTORS SWITCH FEATURES & BENEFITS For more than 100 years, Mersen have been providing the market with
More informationCurrent transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv
Current transformers Outdoor operation SF 6 -gas insulated JGF (245 550) kv General description Current transformers type JGF are used in high voltage switchgear within the 245 550 kv range. They transform
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationContactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en
Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3
More informationResin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK
1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationZinc Oxide Surge Arrester PEXLIM Q
Zinc Oxide Surge Arrester Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages. in areas with high lightning intensity and high
More informationSafety switches with solenoid and separate actuator
Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationCast resin transformers
Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation SF 6 -gas insulated EGF (245 550) kv General description Voltage transformers type EGF are used in high voltage substations within the 245 550 kv range.
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation SF 6 -gas insulated EGF (245 550) kv General description Voltage transformers type EGF are used in high voltage substations within the 245 550 kv range.
More informationINTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.
INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side
More informationHigh Voltage Surge Arresters Buyer s Guide Section PEXLIM R
High Voltage Surge Arresters Buyer s Guide Section PEXLIM R Zinc Oxide Surge Arrester PEXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching
More informationGears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.
Clip lock design for CL-14 series Cat. No. 228-700-520 Cat. No. 228-700-530 (Pair at bottom) (Single at top) The Clip Lock design provides a reliable, high-pressure contact. Ferraz Shawmut CL-14 fuses
More informationMedium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A
Medium voltage switchgear type W rated voltage kv rated current 0 A General The metal-encapsulated, air-insulated medium voltage switchgears, type W are for universal application. They range from compact
More informationPRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT
PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze
More informationMODVAR Low voltage reactive power compensation modules Installation manual
MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Before installation, read this manual carefully and keep at the disposal
More informationTECHNICAL SPECIFICATIONS OF PCC PANEL
S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational
More informationMedium voltage fuses - European Fuses
HV Back-up Fuse-Links according to IEC 60 282- HV fuse-links have been used for reliable protection in medium-voltage switchgear and controlgear and systems for decades. They protect apparatus and equipment
More informationHigh-Voltage Fuse Links according to IEC
High-Voltage Fuse Links according to IEC 60282- Limitor Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical expertise, innovative
More informationSENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationVacuum Circuit Breaker
Vacuum Circuit Breaker 12/24kV VECTOR series Vacuum Circuit Breaker VMS series Metal-clad Switchgear Medium Voltage Systems 003 FM 73638 12/24kV VECTOR VCB Features of the VECTOR Vacuum Circuit Breaker:
More informationInductive voltage transformers
Inductive voltage transformers Outdoor operation SF 6 -gas insulated EGF (245 550) kv General description Voltage transformers type EGF are used in high voltage substations within the 245 550 kv range.
More information15 mm Pilot Valve. More technical specifications are reported in the following pages. 1
15 mm Pilot Valve The 15 mm pilot valve has been designed and developped by Amisco as a logical evolution of the traditional product range manufactured for the pneumatic market. The 15 mm solenoid valve
More informationThis catalogue also includes cooling medium pumps of the types DKP and EKP.
AUTRIA INTRODUCTION FFD offers a full range of low voltage electric motors, single phase motors as well as three phase squirrel cage induction motors for continuous duty. All motors are manufactured according
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationJCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3
Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We offer complete line of Cam Switches with as many as 24 switch contacts. Each contact has two fixed
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationOutdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications
Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers
More informationDCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationType SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear
Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationKEVA 24 Cxx(c) Indoor voltage sensors for NEXANS Instructions for installation, use and maintenance
Medium Voltage Products KEVA 24 Cxx(c) Indoor voltage sensors for NEXANS Instructions for installation, use and maintenance 1. Operating conditions 2 2. Technical details 2 3. Instructions for installation
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More information