High Voltage Surge Arresters Buyer s Guide Section PEXLIM R
|
|
- Octavia Hines
- 5 years ago
- Views:
Transcription
1 High Voltage Surge Arresters Buyer s Guide Section PEXLIM R
2 Zinc Oxide Surge Arrester PEXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy capability and pollution are moderate. Brief performance data System s (U m ) Rated s (U r ) kv kv Superior where low weight, reduced clearances, flexible mounting, non-fragility and additional personnel safety is required. Major component in PEXLINK TM concept for transmission line protection. Nominal discharge current (IEC) Discharge current withstand strength: High current 4/10 µs Low current 2000 µs 10 ka peak 100 ka peak 600 A peak Other data can be ordered on request. Please contact your local sales representative. Energy capability: Line discharge class (IEC) [2 impulses, (IEC Cl ) Fulfils/exceeds requirements of ANSI transmissionline discharge test for 170 kv systems. Class kj/kv (U r )] Short-circuit/Pressure relief capability 50 ka sym External insulation Fulfils/exceeds standards Mechanical strength: Specified long-term load (SLL) Specified short-term load (SSL) Nm Nm Service conditions: Ambient temperature Design altitude Frequency -50 C to +45 C max m Hz ABB Surge Arresters Buyer s Guide Technical information 29
3 Guaranteed protective data kv Max. system Rated Max. continuous TOV capability 2) Max. residual with current wave operating 1) as per IEC as per ANSI/IEEE 30/60 µs 8/20 µs U m U r U c MCOV 1 s 10 s 0.5 ka 1 ka 2 ka 5 ka 10 ka 20 ka 40 ka 24 3) ) More detailed information on the TOV capability and the protective characteristics are given in Publ. 1HSM en. 1) The continuous operating s U c (as per IEC) and MCOV (as per ANSI) differ only due to deviations in type test procedures. Uc has to be considered only when the actual system is higher than the tabulated. Any arrester with U c higher than or equal to the actual system divided by 3 can be selected. 2) With prior duty equal to the maximum single-impulse energy stress (2.5 kj/kv (U r )). 3) Arresters for system s 36 kv or below can be supplied, on request, when the order also includes arresters for higher system s. Arresters with lower or higher rated s may be available on request for special applications. 30 Technical information ABB Surge Arresters Buyer s Guide
4 Guaranteed protective data kv Max. system Rated Max. continuous TOV capability 2) Max. residual with current wave operating 1) as per IEC as per ANSI/IEEE 30/60 µs 8/20 µs U m U r U c MCOV 1 s 10 s 0.5 ka 1 ka 2 ka 5 ka 10 ka 20 ka 40 ka More detailed information on the TOV capability and the protective characteristics are given in Publ. 1HSM en. 1) The continuous operating s U c (as per IEC) and MCOV (as per ANSI) differ only due to deviations in type test procedures. Uc has to be considered only when the actual system is higher than the tabulated. Any arrester with U c higher than or equal to the actual system divided by 3 can be selected. 2) With prior duty equal to the maximum single-impulse energy stress (2.5 kj/kv (U r )). Arresters with lower or higher rated s may be available on request for special applications. ABB Surge Arresters Buyer s Guide Technical information 31
5 Technical data for housings Max. system Rated Housing Creepage distance External insulation * ) Dimensions U m U r 1.2/50 µs dry 50 Hz wet (60s) 60 Hz wet (10s) 250/2500 µs wet Mass A max B C Fig. mm kg mm mm mm YV YV YV YV YH YV YV YV YH YH YV YV YV YH YH YV YV YH Neutral-ground arresters YN YN YN YN YN YN YN * ) Sum of withstand s for empty units of arrester. 32 Technical information ABB Surge Arresters Buyer s Guide
6 Technical data for housings Figure 1 Figure 2 Figure 3 ABB Surge Arresters Buyer s Guide Technical information 33
7 Accessories Line terminals Earth terminals Drilling plans 1HSA L Aluminium 1HSA A Stainless steel 1HSA M Aluminium flag with other items in stainless steel Without insulating base Aluminium 1HSA B Stainless steel 1HSA N Aluminium Insulating base 1HSA H Epoxy resin 1HSA P Stainless steel M12 bolts for connection to structure are not supplied by ABB. Required threaded grip length is mm. 34 Technical information ABB Surge Arresters Buyer s Guide
8 Shipping data Rated Housing Number of arresters per crate One Three Six U r Volume Gross Volume Gross Volume Gross m 3 kg m 3 kg m 3 kg YV YV YV YV YH YV YV YV YH YH YV YV YV YH YV YV YH Neutral-ground arresters YN YN YN YN YN YN YN Each crate contains a certain number of arrester units and accessories for assembly and erection. A packing list is attached externally on each crate. Each separate crate is numbered and the numbers of all crates and their contents are listed in the shipping specification. ABB reserves the right to pack arresters in the most effective/economic combination. Alternate or non-standard crates may involve additional charges. The table above is to be seen as an approximation and specific data for deliveries may differ from the values given. ABB Surge Arresters Buyer s Guide Technical information 35
9 For more information please contact: ABB AB High Voltage Products Surge Arresters SE Ludvika, Sweden Phone: +46 (0) Fax: +46 (0) Copyright 2009 ABB All rights reserved NOTE! ABB AB is working continuously to improve the products. We therefore reserve the right to change designs, dimensions and data without prior notice. Section of 1HSM en Surge Arresters Buyer s Guide, Edition 7.1,
High Voltage Surge Arresters Buyer s Guide Section PEXLIM P-Y
High Voltage Surge Arresters uyer s Guide Section PEXLIM P-Y Zinc Oxide Surge Arrester PEXLIM P-Y Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric
More informationZinc Oxide Surge Arrester PEXLIM Q
Zinc Oxide Surge Arrester Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages. in areas with high lightning intensity and high
More informationZinc Oxide Surge Arrester EXLIM R
Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy
More informationZinc-Oxide Surge Arrester TEXLIM Q-C
Zinc-Oxide Surge Arrester TEXLIM Q-C Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. in areas with very high lightning intensity where
More informationType HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv
Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv HS PEXLIM-P Metal Oxide Surge Arrester HS PEXLIM-P Surge Arresters are used for the protection of switchgear, transformers and other
More informationSurge arrester POLIM-H..SD
Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More informationSurge arrester POLIM-C.. HD
DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10
More informationSurge arrester POLIM-H.. ND
DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More informationHigh Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK
High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK Definitions Transmission Line Arresters Backflashover Occurs when lightning strikes the tower structure or overhead
More informationHigh Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK
High Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK Line surge arresters PEXLINK The concept Both large and small public/private utility owners of transmission systems face a
More informationType POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv
Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv POLIM-S Metal Oxide Gapless Surge Arresters POLIM-S Surge Arresters are used for the protection of switchgear, transformers and other
More informationSurge arrester POLIM-H..N
Data sheet Surge arrester POLIMH..N Technical data Arrester class SH, Station High Line discharge class (LD) 4 Nominal discharge current I n (8/20 µs) 20 ka peak Repetitive charge transfer rating Q rs
More informationHIGH VOLTAGE SURGE ARRESTER SPECIFICATION
HIGH VOLTAGE SURGE ARRESTER SPECIFICATION Applications: (Polymer housed MOA for 110kv) (The polymer housed MOA for 10kv) (Porcelain housed MOA for 220kv) (35kv MOA without gaps for middle phase) (110kv
More informationTransformer bushings, type GOH. Technical guide
Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationCONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.
CONTENTS About the company 4 1. Low-voltage arresters LVA type 5 2. Metal-oxide surge arresters for distribution systems. 6 2.1 PA-DM type 6 Dimensions of arresters of PA-DM 9 2.2 PA-DH types 10 Dimensions
More informationHigh Voltage Surge Arresters Buyer s Guide
High Voltage Surge Arresters Buyer s Guide Table of contents Product information Introduction 3 Definitions 4 Simplified selection procedure 7 Design features - Porcelain-housed surge arresters, EXLIM
More informationResin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide
1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More information3EK7 Medium Voltage Silicone Insulated Surge Arresters
3EK7 Medium Voltage Silicone Insulated Surge Arresters Power Transmission and Distribution Setting new Standards The 3EK7 s mechanical features: Glass-collared MOV, Silicone rubber housing, FRP rods and
More informationGENERAL. CONSTRUCTION External
Surge Arresters VariSTAR Type AZG4 Surge Arresters for Systems through 400 kv IEC 20-kA; Line Discharge Class 4 Electrical Apparatus I235-84 GENERAL VariSTAR AZG4 Surge Arresters incorporate the latest
More informationpower pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3
Manufactured by: Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV-6... 150/10.3 BT-A3/8 Surge Arresters housed in polymer housing, developed to protect switchgear, over
More informationGE TRANQUELLTM Surge Arresters
GE Digital Energy GE TRANQUELLTM Surge Arresters Product Selection & Application Guide Heavy Duty Distribution Class-Polymer and Riser Pole Polymer Arresters IEEE /ANSI C62.11 GE Surge Protection The performance
More informationTable of contents. Product information. Technical information. Other
Contact us High Voltage Surge Arresters Buyer s Guide Document ID 1HSM 9543 12-00en, High Voltage Surge Arresters, Byuer s Guide, Edition 12, 2016-11 Table of contents Product information Introduction
More information1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide
1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationSurge arresters Product overview
Surge arresters Product overview abb Surge arresters from ABB Switzerland ABB Switzerland Ltd has been developing and manufacturing for over a century, metal-oxide (MO) resistors and MO arresters for worldwide
More informationVariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)
CP9817 PAGE: 1 of 16 CERTIFIED TEST REPORT VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC 60099-4 (99-4) 0711 Supersedes 0601 Cooper Industries. All Rights Reserved. CP9817 PAGE:
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More information3EP6 porcelain surge arrester
www.siemens.com/energy/arrester 3EP6 porcelain surge arrester Safe, reliable, long-lasting, and stable Answers for energy. Compact design high mechanical stability Sealing system Spring Maximum values
More informationBushings for High Voltage AC Applications
Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure
More informationVariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified
Surge s Catalog Data CA235022EN Supersedes TD235009EN September 2014 COOPER POWER SERIES VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified General Eaton s Cooper
More informationI Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL
Surge Arresters UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 Electrical Apparatus I235-93 GENERAL UltraSIL Polymer-Housed VariSTAR
More informationResin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK
1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationEXCOUNT-I. User s manual
EXCOUNT-I User s manual Safety information Legal disclaimer Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed.
More informationGE TRANQUELL Surge Arresters
GE Grid Solutions GE TRANQUELL Surge Arresters Product Selection Guide IEC Line Discharge Classes with 2, 3, and 4 Polymer Housings GE Surge Protection The performance and reliability of today s electric
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationINTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.
INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side
More information3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv
3EP1 Surge Arrester Metal-oxide surge arrester without series gaps for high-voltage systems up to U m = 170 kv Rated voltage up to 180 kv Nominal discharge current 10 ka, 8/20 µs Line discharge class LD1,
More informationDynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5
Section 204-1 204 DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5 Web: http://www.hubbellpowersystems.com E-mail: hpsliterature@hps.hubbell.com Printed in USA RGS 1M 204-2 Table of Contents Page
More informationSurge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION
Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationOutdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv
Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker
More informationBOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC
BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA MCA MDA Maximum system voltage U m 420 550 System voltage U s 400 500 Nominal discharge current ka 10 20 High current impulse (4/10 µs)
More information3EK7 Distribution Class Surge Arresters. Answers for energy.
3EK7 Distribution Class Surge Arresters Answers for energy. Siemens at Your Service As a global leader of the electronics industries, Siemens has been active in the fields of power transmission and distribution
More informationBOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC
BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA Maximum system voltage U m 800 System voltage U s 750 Nominal discharge current ka 20 High current impulse (4/10 µs) ka 100 Arrester class
More information3EK7 Distribution Class Surge Arresters. Answers for energy.
3EK7 Distribution Class Surge Arresters Answers for energy. Siemens at Your Service As a global leader of the electronics industries, Siemens has been active in the fields of power transmission and distribution
More information3EQ Composite Housed Surge Arresters
Power Transmission and Distribution 3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters: Your
More informationMEDIUM VOLTAGE NETWORKS
MEDIUM VOLTAGE NETWORKS LIGHTNING ARRESTERS & INSULATORS SICAME GROUP OUR EXPERIENCE With 25 years of experience in the field of over protection for medium lines, DERVASIL designs and manufactures zinc
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3
More informationEnergy Division. PCA Single Column Polymeric Surge Arrester
Energy Division PCA Single Column Polymeric Surge Arrester Bowthorpe EMP pioneered the development of the polymeric composite housed surge arrester in the early 1980 s and since 1986 has a proven service
More informationSF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv
Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application
More informationMinnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014
Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014 Presented By: Steve Brewer Senior Product Manager HPS Arrester Business Unit Traveling Wave Theory/ Overvoltage Protection
More informationVoltage limiting device HVL
Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3
More informationABB in Ludvika, Sweden. High Voltage Valley
Michael Holmgren & Håkan Åkesson, ABB Sweden CIGRE colloquium Sarajevo 13-16 May 2012 ABB in Ludvika, Sweden. High Voltage Valley May 9, 2012 Slide 1 High Voltage Valley High power laboratory STRI & unique
More information3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability
3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability Power Transmission and Distribution 1 A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters:
More informationSurge Arrester 3EL2 superior protection up to 550 kv
Certified according to IEC 60099-4 Edition 2.1 (2006) Surge Arrester 3EL2 superior protection up to 550 Light weight. Strong performance. Answers for energy. Simply irresistible. By resisting wear in any
More informationShielded surge arresters
Shielded surge arresters Nexans, worldwide leader for the cable industry Total sales of billion euros in 2009 The most complete range of cables and cabling systems Plants in 39 countries 22,700 employees
More informationDirectly Molded Polymer Surge Arresters
Directly Molded Polymer Surge Arresters Ideal means to reduce environmental impact Up to 420kV, Comply with IEC60099-4, Line discharge class 2-4 l Long-life performance (Hydrophobic silicone rubber) l
More informationPantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance
Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Table of contents 02 03 04 05 06 07 08 Disconnectors from ABB Maximum reliability and minimal maintenance Technical
More informationSurge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn
Surge arresters UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters electrical apparatus 235-75 General Cooper Power Systems has set a new standard of excellence for polymerhoused
More informationSF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv 06B1-E-0002 Small Space Requirement, High Reliability and Safety ー 72.5 to 145 kv GIS, SDH314/SDHa314
More informationSemi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance
Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 2 Semi-pantograph
More informationTechnical Specification for 33 KV 200 AMPs,H.G,Fuse set.
Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. 1. SCOPE:- This specification covers the manufacture, testing and supply of 33KV 200 Amps, H.G. Fuse sets 2. The 33 KV H.G. Fuses shall be suitable
More informationSurge Arresters. Supply Program. Answers for energy.
Surge Arresters Supply Program www.siemens.com/energy/arrester Answers for energy. Always the Best Solution We offer an extensive range of surge arresters suitable for every application economical and
More informationBowthorpe EMP LV/MV Outdoor Surge Arresters
Bowthorpe EMP LV/MV Outdoor Surge Arresters Bowthorpe EMP LV/MV Surge Arresters for Outdoor Applications Table of Contents Product Classification Voltage Range Page DA Series Distribution Metal Oxide Surge
More informationTransformer bushings, type GOA 250. Installation and maintenance guide
Transformer bushings, type GOA 250 Installation and maintenance guide This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor
More informationTechnical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks
Surge Arresters Technical Data TD235026EN Supersedes November 2003 (TD-228) COOPER POWER SERIES Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks Ø40.74 ±0.41
More informationTechnical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks
Surge Arresters Technical Data TD235027EN Supersedes November 2003 (TD-230) COOPER POWER SERIES Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks Ø40.74 ±0.41 0.051
More informationBus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:
4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:
More informationOIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC
OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench
More informationStation Class Polymeric Surge Arresters
The essential feature of the internal construction is the homogeneous resin and glass fibre bond over the complete insulated surface of the ZnO varistor elements. The arrester module has good conductivity
More informationOutdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications
Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers
More informationSX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products
Hi-Tech SX Full-Range Current-Limiting Fuses Provides both overload and fault current protection for distribution equipment in a single fuse body. Trans-Guard SX Full-Range Current-Limiting Fuse As a full-range
More informationUltraSIL polymer-housed VariSTAR station-class surge arresters
Surge s Catalog Data CA235013EN Supersedes August 2015 COOPER POWER SERIES UltraSIL polymer-housed VariSTAR station-class surge arresters General Eaton has set a new standard of excellence for polymer-housed
More informationTransformer bushings, type GSA-OA Technical guide
Transformer bushings, type GSA-OA Technical guide ZSE 2750- en, Rev. 5, 2005-05-5 This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to
More informationLive Tank Circuit Breakers Buyer s Guide - Section LTB family
Live Tank Circuit Breakers Buyer s Guide - Section LTB family Table of contents Page Introduction 3 Auto-Puffer 8 Design features and advantages: LTB circuit breaker family 10 Technical catalogue LTB circuit
More information023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA
023 : 2006 CEB STANDARD 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA Specification for 12kV & 36kV LOAD BREAK SWITCHES CEB Standard 023 : 2006 CEYLON ELECTRICITY BOARD No. 50, Sir
More informationDAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design
DAQO Technical Differences of Isolated Phase Bus Standards Study of Design Standard Variances, Insulator Design and Shipping Section Design Global Reference Medium Voltage Electrical Equipment Standards
More informationSurge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features
Surge s Electrical Apparatus 235-99 General Cooper Power Systems set the standard for design, manufacturing and delivery of polymeric distribution arresters with the UltraSIL polymerhoused arrester family.
More informationHigh voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv
High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv PASS M0S 252 kv Innovation In today s market, the HV substation is increasingly becoming a key element
More informationMedium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB
Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...
More information1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide
1ZSE 2750-111 en, Rev. 9 Transformer bushings, type GSA-OA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationType SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear
Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated
More informationQ pole Pole Mounted Capacitor System
Q pole Pole Mounted Capacitor System Introduction The ABB Qpole pole mount capacitor system is an economical solution for shunt reactive compensation on overhead distribution networks. The Qpole is suitable
More informationRetrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2
Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2 Table of Contents 1 Introduction... 4 2 Description of retrofit circuit-breaker 8DN8... 5 3 Technical data for retrofit circuit-breaker
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationIndoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A
Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.
More informationAll rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.
Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.
More informationPower IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2
Power IT Compact Secondary Substations, CSS Low Voltage Switchboard, LVS2 LVS ABB s New Low Voltage Switchboard for Power IT CSS LVS2 is a freestanding low voltage switchboard, as it is designed with a
More informationNXPLUS C Single busbar. Maintenance-free for lifetime
NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage
More informationj Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
j Schedule of Accreditation Laboratory locations: Ridley Street lyth Northumberland NE24 3AG United Kingdom ORE Catapult Development Services Limited a subsidiary of Contact: Geoff Richardson Tel: +44
More informationIndependent Testing Laboratory for High Voltage Equipment
T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.
More informationOHIO BRASS AIKEN, SC, USA
Section 31-1 31 Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters Copyright 20 Hubbell Incorporated Printed in USA 31-2 Table of Contents Page Warranty 31-2 Introduction 31-3 Distribution
More informationNRB Disconnector for outdoor installation
NRB Disconnector for outdoor installation Rated voltage: Rated current: 12 72, 5 kv 1250 2500 A Several erection alternatives Simple structure, easy to install Self cleaning contacts with magnetic locking
More informationZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.
DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for
More informationpower cable accessories
power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten
More informationZX2 Gas-insulated medium voltage switchgear
Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters
More informationa Nexans company Catalogue 2008
a Nexans company Catalogue 008 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage
More informationINTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017
INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer,
More information