1 a Nexans company Catalogue 008
2 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: pre-moulded EPDM or silicone rubber connectors, terminations and joints for cables and epoxy bushings for transformers and switch gear, as well as a large range of cold-shrinkable terminations and joints from to 4 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 900 Certificate Since 99, Euromold s commitment to quality is demonstrated by its ISO 900 certification. International standards All our products meet the International standards like CENELEC HD 69., CENELEC EN 5080, IEC 6037, IEEE 386 & 404 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 000, Euromold s independent ELAB laboratory obtained the BELTEST accreditation no.9-t-iso 705 conform with the European standards for laboratories ISO 705 for electrical testing of medium voltage cable accessories according to the International standards IEC 644 and HD 69. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve.
3 SEPARABLE CONNECTORS AND BUSHINGS INTERFACE A Table of contents 58LR - elbow connector 5SR - straight connector 5SP - straight plug 56SA - surge arrester PITO-E - plug-in termination 80AR- /- /-3 and 80AR--G /-3-G - equipment bushing 80A-4P-O - in-air bushing Fixings for equipment bushings Accessories Bail restraints Interface A Dimensions according to European CENELEC EN 5080 and 508 (in mm). 03/008 3
4 Connecting possibilities 4
5 58LR INTERFACE A ELBOW CONNECTOR Application Separable elbow connector designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors...). Also connects cable to cable, using the appropriate mating part. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A - 50 A interface as described by CENELEC EN 5080 and Conductor connector. 6. Earthing lead (-/G version only). mm mm Specifications and standards The separable connector 58LR meets the requirements of CENELEC HD Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min. max. 58LR/G 58LR K58LR/G K58LR /008 5
6 Kit contents The complete (K)58LR or (K)58LR/G elbow connector kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)58LR/G-W-X connector kit for Connector housing (K)58BLR/G-W Cable reducer CA smaller sizes Conductor contact 64LRC-X Pin contact + hex key 54LRF Bail restraint 50BA-B Connector housing (K)58BLR-W Cable adaptor TL (K)58LR-W-X+TL connector kit for larger sizes Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Table W Ordering part number 58LR/G--X 58LR/G-3-X 58LR-FB-X+TL 58LR-FG-X+TL 58LR-GA-X+TL 58LR-GAB-X+TL 58LR-GH-X+TL Dia. over core insulation (mm) min. max Table X Example: The copper wire screened cable is 4 kv, 50 mm stranded aluminium with a diameter over core insulation of 0.4 mm. Order a K58LR-FG-50(K) M--+TL elbow connector kit. Conductor sizes (mm²) Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - - 6(K)M-- 5(K)M-- 5KM-- 5(K)M-- 35(K)M-- 35KM-- 35(K)M-- 50(K)M-- 50(K)M-- 50(K)M-- 70(K)M-- 70(K)M-- 70(K)M-- 95(K)M-- 95(K)M-- 95(K)M-- For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. 6
7 Application Separable straight connector designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors...). Also connects cable to cable, using the appropriate mating part. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. 5SR INTERFACE A STRAIGHT CONNECTOR Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A - 50 A interface as described by CENELEC EN 5080 and Conductor connector. 6. Earthing lead (-/G version only). 00 mm 6 55 mm Specifications and standards The separable connector 5SR meets the requirements of CENELEC HD Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min. max. 5SR/G 5SR K5SR/G K5SR /008 7
8 Kit contents The complete (K)5SR or (K)5SR/G straight connector kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)5SR/G-W-X connector kit for Connector housing (K)5SRH/G-W Cable reducer CA smaller sizes (K)5SR-W-X+TL connector kit for Conductor contact 5SRC-X Bail restraint 5BA Connector housing (K)5SRH-W Cable adaptor TL larger sizes Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Table W Ordering part number 5SR/G--X 5SR/G-3-X 5SR-FB-X+TL 5SR-FG-X+TL 5SR-GA-X+TL 5SR-GAB-X+TL 5SR-GH-X+TL Dia. over core insulation (mm) min. max Table X Example: The copper wire screened cable is 4 kv, 50 mm stranded aluminium with a diameter over core insulation of 0.4 mm. Order a K5SR-FG-50(K) M--+TL straight connector kit. Conductor sizes (mm²) Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - - 6(K)M-- 5(K)M-- 5KM-- 5(K)M-- 35(K)M-- 35KM-- 35(K)M-- 50(K)M-- 50(K)M-- 50(K)M-- 70(K)M-- 70(K)M-- 70(K)M-- 95(K)M-- 95(K)M-- 95(K)M-- For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. 8
9 Application Separable straight plug designed to connect polymeric insulated cable to cable. Mates with the elbow, straight and branch joint connectors. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each straight plug is tested for AC withstand and partial discharge prior to leaving the factory. 5SP INTERFACE A STRAIGHT PLUG Up to 4 kv - 00 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A interface as described by CENELEC EN 5080 and Conductor connector. 3 mm Dia. 54 mm Separable plug type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min. max. 5SP K5SP /008 9
10 Kit contents The complete (K)5SP straight plug kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)5SP-W-X+TL straight plug kit Straight plug housing (K)5SPH-W Conductor contact 5SPC-X Cable adaptor TL Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Table W Ordering part number 5SP-A-X+TL-FA/FAB 5SP-B-X+TL-FB/FG 5SP-B-X+TL-GA/GAB 5SP-C-X+TL-GB/GH Dia. over core insulation (mm) min. max Table X Example: The copper wire screened cable is kv, 50 mm stranded aluminium with a diameter over core insulation of 6.9 mm. Order a 5SP-A-50(K)M-- +TL-FA/FAB straight plug kit. Conductor sizes (mm²) Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - - 6(K)M-- 5(K)M-- 5KM-- 5(K)M-- 35(K)M-- 35KM-- 35(K)M-- 50(K)M-- 50(K)M-- 50(K)M-- 70(K)M-- 70(K)M-- 70(K)M-- 95(K)M-- 95(K)M-- 95(K)M-- For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. 0
11 Application Surge arrester designed to protect and 4 kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. Technical characteristics This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand and partial discharge prior to leaving the factory. 56SA INTERFACE A SURGE ARRESTER Up to 4 kv 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Surge arrester comprising:. Bail restraint.. Conductive EPDM insert. 3. Type A - 50 A interface as described by CENELEC EN 5080 and Pin contact. 5. Contact disc. 6. Copper shunt. 7. Metal oxide valve elements. 8. Aluminium spacer. 9. Steel cap. 0. Earth connection.. Insulating EPDM layer moulded between the insert and the jacket.. Conductive EPDM jacket Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max. continuous operating voltage Uc (kv) Steep current residual 5 ka [/0 µs] (kv) Lightning current residual 5 ka [8/0 µs] (kv) High current impulse withstand (ka) 56SA- 56SA-5 56SA-8 56SA- 56SA /008
12 Typical application and dimensions To order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (rms) of kv. Order a 56SA- surge arrester.
13 Application Separable termination designed to connect overhead lines or bus bars to equipment. Is suitable for indoor and outdoor use for medium polluted atmosphere. Technical characteristics Each plug-in termination is tested for AC withstand prior to leaving the factory. PITO-E PLUG-IN TERMINATION Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The plug-in termination is a moulded epoxy insulated part. It meets the type A - 50 A interface as described in CENELEC EN 5080 and 508. Specifications and standards The separable termination PITO-E meets the requirements of IEC 37. To order the plug-in termination for or 4 kv, specify PITO-E. The kit includes the bail restraint and brass nuts. In mm. Plug-in termination type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) PITO-E PITO-E /008 3
14 80AR- /- /-3 and 80AR--G /-3-G INTERFACE A EQUIPMENT BUSHING Application For use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Specifications and standards The plug-in type equipment bushings 80AR-X meet the requirements of CENELEC EN 5080 and IEC Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The equipment bushing is a moulded epoxy insulated part in accordance with CENELEC EN The 80AR- bushing has a length B outside this standard. The standard bushings, (K)80AR- /- /-3, are equipped with 6 tabs for the bail restraint. The (K)80AR--G and (K)80AR-3-G are equipped with 4 tabs and threaded inserts M6x (-G version). 80AR--G /-3-G 80AR- /- /-3 To order the equipment bushing, specify the type. The bushings are supplied with an earth lead (/J) or an earth plate (/GS). This earth connection must be specified when ordering. In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) A Dimensions (mm) B 80AR-(-G) K80AR-(-G) 80AR- K80AR- 80AR-3(-G) K80AR-3(-G) /008 4
15 Application For use in equipment insulated with air, typically for transformers, motors, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 80A-4P-O INTERFACE A IN-AIR BUSHING Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The equipment bushing is a moulded epoxy insulated part in accordance with CENELEC EN 508. Specifications and standards The plug-in type equipment bushings 80A-4P-O meet the requirements of CENELEC EN 508 and IEC To order the equipment bushing, specify the type. The bushings are supplied with an earth lead. To include the ring clamp, add: /B, if per British standards. /D, if per German standards. /F, if per French standards. E.g. 80A-4P-O/D. In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) 80A-4P-O 80A-4P-O /008 5
16 FIXINGS FOR EQUIPMENT BUSHINGS INTERFACE A 80AR-/GS, 80AR--G/GS, 80AR-/GS, 80AR-3/GS and 80AR-3-G/GS bushings NFC French standards. 80AR-/J, 80AR--G/J, 80AR-/J, 80AR-3/J and 80AR-3-G/J bushings DIN German standards. 03/008 In mm. 6
17 80A-4P-O In-air bushing In mm. 7
18 ACCESSORIES INTERFACE A Application For use with connectors and bushings with an interface A as described by CENELEC EN 5080 and 508. Technical characteristics All these products, except the earthing plug, are tested for AC withstand and partial discharge prior to leaving the factory. Up to 4 kv 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv 50DR Dead-end receptacle Fits over a bushing with a type A interface to provide 'deadend' facility. Renders the assembly watertight. Order 50DR for kv or K50DR for 4 kv applications. The dead-end receptacle can be supplied with an earth lead. Order: -/G. E.g. K50DR/G. 50DP Dead-end plug Plugs into connectors or receptacles to provide 'deadend' facility. Renders the assembly watertight Order 50DP for kv or K50DP for 4 kv applications. 5SOP Stand-off plug Is designed to support and 'dead-end' connectors with a type A interface when removed from equipment. Order 5SOP for kv or K5SOP for 4 kv applications. 50GP Earthing plug Is designed to support and earth connectors with a type A interface when removed from equipment. Order 50GP for kv or 4 kv applications. 03/008 8
19 00T Separable tee connector Is designed to connect three cables of the same or varying sizes or two cables to equipment. For an adapted bail, please refer to the catalogue or contact our representative. Order 00T for kv or K00T for 4 kv applications. 00X Separable cross connector Is designed to connect four cables of the same or varying sizes or three cables to equipment. For an adapted bail, please refer to the catalogue or contact our representative. Order 00X for kv or K00X for 4 kv applications. 50J3-U-8 Three-way junction Provides a flexible means of connecting two or three cables of the same or varying sizes. For an adapted bail, please refer to the catalogue or contact our representative. Order 50J3-U-8 for kv or K50J3-U-8 for 4 kv applications. Kit MT Earthing kit for copper tape screened cables Contains a tinned copper braid (5 mm² - L=500 mm), a tinned copper wire for cleating and water sealing mastic. Order Kit MT for kv or 4 kv applications. 9
20 BAIL RESTRAINTS INTERFACE A Application For use with connectors, receptacles and bushings with an interface A as described by CENELEC EN 5080 and 508. The type of bail restraint is defined by its intended use with different types of connector, receptacle and/or bushing. To order the bail restraint, specify the type needed. 47BA. (K)5SR straight connector,. (K)00T tee connector and 3. (K)50DR dead-end receptacle. 49BA. (K)58LR elbow connector,. (K)00T tee connector and 3. (K)50DR dead-end receptacle BA. (K)58LR elbow connector and. (K)50DP dead-end plug. 50BA-B. (K)58LR elbow connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three-way junction. 03/008 0
21 50TB-. (K)00T tee connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three way junction. 53BA. (K)5SR straight connector and. (K)50DP dead-end plug. 5BA. (K)5SR straight connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three-way junction. 54BA-CS80. (K)5SP straight plug and. (K)50DR dead-end receptacle. 55BA-. x (K)5SR straight connector and. (K)00T tee connector. 5BA. (K)50DR dead-end receptacle and. an interface A equipment bushing (shown) or (K)50J3-U-8 three-way junction. 55BA- - CS80. (K)5SP straight plug and. (K)58LR elbow connector or 3. (K)00T tee connector. 3
22 56BA-. (K)00T tee connector and. (K)50DP dead-end plug. 59BA. x (K)58LR elbow connector and. (K)00T tee connector 57BA - CS8. (K)5SR straight connector and. (K)5SP straight plug. 00BA. (K)5SR straight connector and. (K)00X cross connector. 58BA. (K)5SR straight connector,. (K)00T tee connector and 3. (K)58LR elbow connector. 3 0BA. (K)58LR elbow connector and. (K)00X cross connector.
23 0BA. (K)5SR straight connector,. (K)00X cross connector and 3. (K)50DR dead-end receptacle. 3 06BA. (K)5SR straight connector,. (K)00X cross connector and 3. (K)58LR elbow connector. 3 03BA. (K)58LR elbow connector,. (K)00X cross connector and 3. (K)50DR dead-end receptacle. 3 07BA. x (K)58LR elbow connector and. (K)00X cross connector. 04BA. (K)00X cross connector and. (K)5SP straight plug. 08BA. (K)00X cross connector and. (K)50DR dead-end receptacle. 05BA. (K)00X cross connector and. x (K)5SR straight connector. 3
24 Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan, B-930 Erembodegem Tel.: +3 (0) Fax: +3 (0) info.euromold@nexans.com 03/008 Catalogue also available on CD-ROM
a Nexans company Catalogue 2009
a Nexans company Catalogue 009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage
More informationINTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017
INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 07 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Nexans is the leading European specialised designer, manufacturer
More informationa Nexans company Catalogue 2015
a Nexans company Catalogue 05 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationNexans Network Solutions Div. Euromold
Catalogue 0 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for
More informationa Nexans company Catalogue 2006
a Nexans company Catalogue 2006 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationa Nexans company Catalogue 2007
a Nexans company Catalogue 2007 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationNexans Network Solutions Div. Euromold
a Nexans company Catalogue 2011 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationa Nexans company Catalogue 2012
a Nexans company Catalogue 2012 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationTHORNE & DERRICK UK TEL FAX TEL FAX
WWW.CABLEJOINTS.CO.UK THORNE & DERRICK UK TEL 0044 191 490 1547 FAX 0044 477 5371 TEL 0044 117 977 4647 FAX 0044 977 5582 WWW.THORNEANDDERRICK.CO.UK a Nexans company Catalogue 2006 EUROMOLD COMPANY PRESENTATION
More informationa Nexans company Catalogue 2009
a Nexans company Catalogue 2009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationINTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017
INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer,
More informationa Nexans company Catalogue 2007
a Nexans company Catalogue 2007 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationNexans Network Solutions Div. Euromold
Catalogue 2012 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories
More informationTHORNE & DERRICK UK TEL FAX TEL FAX
a Nexans company Catalogue 2006 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationa Nexans company Medium voltage symmetrical separable connectors - Interface C -
a Nexans company Medium voltage symmetrical separable connectors - Interface C - Catalogue 2011 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised
More informationa Nexans company Catalogue 2011
a Nexans company Catalogue 2011 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationa Nexans company Catalogue 2009
a Nexans company Catalogue 2009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationNexans Network Solutions Div. Euromold
a Nexans company Catalogue 2011 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationINTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017
INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer
More informationINTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017
INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer,
More informationa Nexans company Catalogue 2015
a Nexans company Catalogue 2015 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationPower cables accessories for use in potentially explosive atmospheres
Power cables accessories for use in potentially explosive atmospheres Catalogue 2013 NEXANS POWER ACCESSORIES EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor
More informationa Nexans company Catalogue 2008
a Nexans company Catalogue 2008 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium
More informationNexans Network Solutions Div. Euromold
Catalogue 2012 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories
More informationShielded surge arresters
Shielded surge arresters Nexans, worldwide leader for the cable industry Total sales of billion euros in 2009 The most complete range of cables and cabling systems Plants in 39 countries 22,700 employees
More informationglobal leader in cables
Nexans, global leader in cables Total sales of 6 billion euros in 2010 The most complete range of cables and cabling systems Plants in 40 countries 23,700 employees worldwide Complete offers for every
More informationHigh Voltage Accessories up to 72.5 kv
High Voltage Accessories up to 72.5 kv Technical instructions and application information The data given were determined diligently, but do not release our customers of the duty to carry out tests themselves
More informationACCESSORIES. Application For use with connectors and bushings with an interface C as described by CENELEC EN and
ACCESSORIES INTERFACE C Application For use with connectors and bushings with an interface C as described by CENELEC EN 50180 and 50181. Technical characteristics All these products, except the earthing
More information(K),(M),(P)489TB/G Up to 42 kv
IS91374-ENG - 489TB/G-45/S 22 October 2012 - Revision 1 - Supersedes edition of 4 May 2012 Page 1 of 9 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation
More informationpower cable accessories
power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten
More informationa Nexans company Catalogue 2012
a Nexans company Catalogue 2012 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More information(K),(M)430TB/G Up to 36 kv
IS90722-ENG - 430TB/G-45 25 June 2009 - Revision 8A - Supersedes edition of 25 November 2008 Page 1 of 10 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation
More informationINTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.
INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side
More informationEnergy Division. PCA Single Column Polymeric Surge Arrester
Energy Division PCA Single Column Polymeric Surge Arrester Bowthorpe EMP pioneered the development of the polymeric composite housed surge arrester in the early 1980 s and since 1986 has a proven service
More information600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:
Issue Date: 07/17/2017 Page: 1 of 5 PSS- K656LR Elbow Connector (with Test ) Applications: The Elastimold K656LR (with test point) is designed to provide fully shielded, dead-front submersible cable connections
More informationMV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS
MEDIUM VOLTAGE MV TERMINATIONS INDOOR SINGLE CORE TERMINATION - ELTI-1C APPLICATION Utilisation indoor. in boxes and compact switchgears. in terminal boxes located outdoor and subject to condensation.
More informationIS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)
IS94012-ENG - AFN 20-45 5 February 2013 - Revision 6 - Supersedes edition of 28 January 2013 Page 1 of 7 CAUTION: Read instructions thoroughly and completely prior to beginning installation. Installation
More informationCold-shrinkable Silicone 12 kv - 24 kv - 36 kv
EUROMOD NV 0/00 www.think-media.be Accessories for medium voltage power cables Terminations Cold-shrinkable Silicone kv - kv - 6 kv Catalogue 0/00 TERMINATIONS TABE OF CONTENTS COD-SHRINKABE SIICONE TERMINATIONS
More informationZinc-Oxide Surge Arrester TEXLIM Q-C
Zinc-Oxide Surge Arrester TEXLIM Q-C Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. in areas with very high lightning intensity where
More informationMedium Voltage. Joints & Terminations
57 - Cold Shrink Joints Supporting Core Radially shrinkable elastomeric splice Semi-conductive layer High permitivity insulation layer 6.6/11/(12) kv 3M QS1000 is a one-piece cold shrink joint body manufactured
More informationELASTIMOLD UNDERGROUND CABLE ACCESSORIES
ELASTIMOLD UNDERGROUND CABLE ACCESSORIES ELASTIMOLD FEATURES AND BENEFITS The Elastimold brand is recognised as the leading producer of premoulded cable accessory components worldwide. Utilising specially
More informationZinc Oxide Surge Arrester EXLIM R
Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy
More informationCONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.
CONTENTS About the company 4 1. Low-voltage arresters LVA type 5 2. Metal-oxide surge arresters for distribution systems. 6 2.1 PA-DM type 6 Dimensions of arresters of PA-DM 9 2.2 PA-DH types 10 Dimensions
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More informationLoadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.
3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200
More informationSeparable Connectors and Kits
Important Notice While Woer has made every effort to ensure the accuracy of the information in this catalog, Woer does not guarantee that it is errorless. Nor does Woer make any other warranty or guarantee
More informationTechnical Guarantees For Electrical Materials & Equipments 1 Technical Guarantees No. IDT_1600 22/0.4 KV Low Losses, 3 phase, Indoor Distribution Transformer 1600 KVA Rating No Description Unit Requirements
More informationZinc Oxide Surge Arrester PEXLIM Q
Zinc Oxide Surge Arrester Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages. in areas with high lightning intensity and high
More informationPower cable accessories catalogue
Power cable accessories catalogue MV Terminations & MV Joints Excellence in Training Obtain an accreditation in a wide range of joints and terminations. Courses available in low voltage, medium voltage
More informationSEE PRODUCT GUIDE PG-PC-E FOR SURGE ARRESTER APPLICATIONS THREADED STUD 600 SERIES ELBOW THREADED STUD CONNECTING BUSHING EXTENDER COMPRESSION LUG
ACCESSORIES 600 Series Deadbreak 600 Series deadbreak elbows, straight receptacles, junctions, vault stretchers and accessories are used to connect equipment and cable on primary feeder and network circuits.
More informationSurge arrester POLIM-H..SD
Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More informationH e a t s h r i n k P r o d u c t G u i d e
P o w e r P r o d u c t s H e a t s h r i n k P r o d u c t G u i d e Introduction HellermannTyton is a world leader in providing systems and solutions for heatshrink applications. HellermannTyton utilises
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationBOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC
BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA Maximum system voltage U m 800 System voltage U s 750 Nominal discharge current ka 20 High current impulse (4/10 µs) ka 100 Arrester class
More informationCellplux Plug-in Technology
simple, secure, quick to assemble solution for entire cross-section range only standard tool required unlimited shelf life type tested to CENELEC HD 629.1 D827 SAP-No. 206884 0313 Perfect connection Profit
More informationCATALOG. Underground cable accessories
CATALOG Underground cable accessories 2 ELASTIMOLD UNDERGROUND CABLE ACCESSORIES Choose Thomas & Betts and connect to the power you need For over 100 years, Thomas & Betts has successfully applied innovative
More informationIEC Separable Connectors 17.5 kv/24 kv, 630A
IEC Separable Connectors 17.5 kv/24 kv, 630A Front T-Body / Coupling (Rear) T-Body Connector Application The Chardon T-Body connectors are used to terminate polymeric cable to dead front apparatus such
More informationSurge arresters Product overview
Surge arresters Product overview abb Surge arresters from ABB Switzerland ABB Switzerland Ltd has been developing and manufacturing for over a century, metal-oxide (MO) resistors and MO arresters for worldwide
More informationBus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:
4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:
More informationCompleting the picture
HIGH VoltaGe cable accessories for 72 kv up to 170 kv Completing the picture based on experience is the future nkt cables GmbH nkt was established in 1891 as cable manufacturer. in 1999 nkt a/s denmark
More information1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationBOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC
BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA MCA MDA Maximum system voltage U m 420 550 System voltage U s 400 500 Nominal discharge current ka 10 20 High current impulse (4/10 µs)
More informationMEDIUM VOLTAGE NETWORKS
MEDIUM VOLTAGE NETWORKS LIGHTNING ARRESTERS & INSULATORS SICAME GROUP OUR EXPERIENCE With 25 years of experience in the field of over protection for medium lines, DERVASIL designs and manufactures zinc
More informationHigh Voltage Surge Arresters Buyer s Guide Section PEXLIM R
High Voltage Surge Arresters Buyer s Guide Section PEXLIM R Zinc Oxide Surge Arrester PEXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching
More information3EP6 porcelain surge arrester
www.siemens.com/energy/arrester 3EP6 porcelain surge arrester Safe, reliable, long-lasting, and stable Answers for energy. Compact design high mechanical stability Sealing system Spring Maximum values
More informationSurge arrester POLIM-C.. HD
DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10
More informationSurge arrester POLIM-H.. ND
DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10
More information3M Electrical Markets Division Loadbreaks Deadbreaks Junctions Surge Arresters Disconnectable Joints 3 3M is the exclusive distributor for Richards Medium Voltage cable accessories in Canada. www.richards-mfg.com
More informationNexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant
P o w e r C a b l e A c c e s s o r i e s Global expert in cables and cabling system Formed from Alcatel Cables and Components, Nexans inherits 100 years professional experience in manufacturing cables
More informationItem Code Description Unit Qty Total
UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories
More informationIEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector
www.chardongroup.com IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector Application Chardon Front T-Body / Coupling (Rear) T-Body connectors are fully
More informationpower pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3
Manufactured by: Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV-6... 150/10.3 BT-A3/8 Surge Arresters housed in polymer housing, developed to protect switchgear, over
More informationQTII (X) Series Silicone Rubber Cold Shrink Termination Kits
QTII (X) Series Silicone Rubber Cold Shrink Termination Kits For MV Armored/Non-Armored Cables up to 36kV DATA SHEET Update: August 2006 1. Product Description The 3M QTII (X) Series are Silicone Rubber
More informationSilicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)
Silicone Suspension/Tension Insulator 120kN up to LIWV 450kV (BIL) CABLE SYSTEMS FOR ENERGY & ROLLING STOCK APPLICATIONS MV Silicone Tension Insulators The high tensile strength of glass fibre has been
More informationDeadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL
Deadbreak Apparatus Connectors 600 A 15/25 kv Class BOL-T Deadbreak Connector Electrical Apparatus 600-30 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class BOL-T Deadbreak Connector is used to terminate
More informationTransformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC
Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC 60137-2008 High current bushings for transformer Features Bushing Type CFPT version Porcelain Insulator Trench RIG technology for
More informationBUSHINGS: GENERAL INFORMATION
BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency
More information1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide
1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationGROUP D. Switch & Protective device.
GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated
More informationDynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5
Section 204-1 204 DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5 Web: http://www.hubbellpowersystems.com E-mail: hpsliterature@hps.hubbell.com Printed in USA RGS 1M 204-2 Table of Contents Page
More informationStation Class Polymeric Surge Arresters
The essential feature of the internal construction is the homogeneous resin and glass fibre bond over the complete insulated surface of the ZnO varistor elements. The arrester module has good conductivity
More informationBowthorpe EMP LV/MV Outdoor Surge Arresters
Bowthorpe EMP LV/MV Outdoor Surge Arresters Bowthorpe EMP LV/MV Surge Arresters for Outdoor Applications Table of Contents Product Classification Voltage Range Page DA Series Distribution Metal Oxide Surge
More informationINSTALLATION PRODUCTION TESTS
Deadbreak Apparatus Connectors 600 A 15/25 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-10 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class Bol-T Deadbreak Connector is used to terminate
More informationGE TRANQUELL Surge Arresters
GE Grid Solutions GE TRANQUELL Surge Arresters Product Selection Guide IEC Line Discharge Classes with 2, 3, and 4 Polymer Housings GE Surge Protection The performance and reliability of today s electric
More informationType POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv
Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv POLIM-S Metal Oxide Gapless Surge Arresters POLIM-S Surge Arresters are used for the protection of switchgear, transformers and other
More informationGas Insulated Switchgear
Gas Insulated Switchgear Your partner in energy solutions CG Electric Systems Hungary CG Electric Systems Hungary (previously known as Ganz Electric) has a history of over a 130 years as a high technology
More information3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability
3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability Power Transmission and Distribution 1 A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters:
More information3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv
3EP1 Surge Arrester Metal-oxide surge arrester without series gaps for high-voltage systems up to U m = 170 kv Rated voltage up to 180 kv Nominal discharge current 10 ka, 8/20 µs Line discharge class LD1,
More informationENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC. Bowthorpe EMP Transmission Line Surge Arresters (IEC)
ENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC Bowthorpe EMP Transmission Line Surge Arresters (IEC) TRANSMISSION LINE SURGE ARRESTERS Numerous technical publications have stated that lightning is responsible
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11068-09-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 10.07.2014 to 09.07.2019 Holder of certificate: Karlsruher
More informationBushing Insulators according to DIN and UNEL Standards
Bushing Insulators according to DIN and UNEL Standards Description and general specifications Outdoor transformer bushing DIN 42532 and UNEL 38159/74 rated current 630A Bushing EN 50180 12-24-36/630-1250-2000-3150
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More informationBushings for High Voltage AC Applications
Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure
More information3EK7 Medium Voltage Silicone Insulated Surge Arresters
3EK7 Medium Voltage Silicone Insulated Surge Arresters Power Transmission and Distribution Setting new Standards The 3EK7 s mechanical features: Glass-collared MOV, Silicone rubber housing, FRP rods and
More information3 TM Cold Applied Barrier Boot System
M Technical Information : Barrier Boot TM Cold Applied Barrier Boot System For rated voltages 6.5/11(12) kv and 8.7/15(17.5) kv 92-EE 717-1 Product Description The Cold Applied Barrier Boot System consist
More informationOIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC
OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench
More informationTransmission Porcelain Surge Arresters
Transmission Porcelain Surge Arresters ENERGY DIVISION Porcelain Surge Arresters Porcelain surge arresters are available for applications up to 400 systems. Porcelain housing designs have been used by
More informationLoadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL
Loadbreak Apparatus Connectors 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal Electrical Apparatus 500-10-7 GENERAL The Cooper Power Systems Loadbreak Elbow Connector is
More informationKEVA 24 Cxx(c) Indoor voltage sensors for NEXANS Instructions for installation, use and maintenance
Medium Voltage Products KEVA 24 Cxx(c) Indoor voltage sensors for NEXANS Instructions for installation, use and maintenance 1. Operating conditions 2 2. Technical details 2 3. Instructions for installation
More informationTE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM
Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. industry photo. This image and the one above should be different versions of the same photo