High Voltage Surge Arresters Buyer s Guide Section PEXLIM P-Y

Size: px
Start display at page:

Download "High Voltage Surge Arresters Buyer s Guide Section PEXLIM P-Y"

Transcription

1 High Voltage Surge Arresters uyer s Guide Section PEXLIM P-Y

2 Zinc Oxide Surge Arrester PEXLIM P-Y Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages. in areas with very high lightning intensity where grounding or shielding conditions are poor or incomplete for important installations where energy requirements are very high (e.g. very long lines, capacitor protection). rief performance data System voltages (U m ) Rated voltages (U r ) Nominal discharge current (IE) lassifying current (ANSI/IEEE) kv kv 20 ka peak 15 ka peak Superior where low weight, reduced clerances, flexible mounting, non-fragility and additional personnel safety is required. ischarge current wittstand strength: High current 4/10 µs Low current µs 100 ka peak A peak Other data can be ordered on request. Please contact your local sales representative. Energy capability: Line discharge class (IE) [2 impulses, (IE l ) Fulfils/exceeds requirements of ANSI transmissionline discharge test for 362 kv systems. lass kj/kv (Ur)] Short-circuit/Pressure relief capability 65 ka sym External insulation Fulfils/exceeds standards Mechanical strength: Specified long-term load (SLL) Specified short-term load (SSL) Nm Nm Service conditions: Ambient temperature esign altitude Frequency -50 to +45 max m Hz 58 Technical information A Surge Arresters uyer s Guide

3 Guranteed protective data Max. system voltage Rated voltage Max. continuous TOV capability 2) Max. residual voltage with current wave operating voltage 1) as per IE as per ANSI/IEEE 30/60 µs 8/20 µs U m U r U c MOV 1 s 10 s 1 ka 2 ka 3 ka 5 ka 10 ka 20 ka 40 ka More detailed information on the TOV capability and the protective characteristics are given in Publ. 1HSM en. 1) The continuous operating voltages U c (as per IE) and MOV (as per ANSI) differ only due to deviations in type test procedures. U c has to be considered only when the actual system voltage is higher than the tabulated. Any arrester with U c higher than or equal to the actual system voltage divided by 3 can be selected. 2) With prior duty equal to the maximum single-impulse energy stress (7.0 kj/kv (U r )). Arresters with lower or higher rated voltages may be available on request for special applications. A Surge Arresters uyer s Guide Technical information 59

4 Technical data for housings Max. system voltage Rated voltage Housing reepage distance External insulation * ) imensions U m U r 1.2/50 µs dry 50 Hz wet (60s) 60 Hz wet (10s) 250/2500 µs wet Mass A max Fig. mm kg mm mm mm mm YH YH YV YM YH YV YH YH YV YH *) Sum of withstand voltages for empty units of arrester. 60 Technical information A Surge Arresters uyer s Guide

5 Technical data for housings Figure 1 Figure 2 Figure Figure 4 Figure 5 Figure 6 A Surge Arresters uyer s Guide Technical information 61

6 Accessories Line terminals Earth terminals max 34 4 M12 (4x) HSA L Aluminium 1HSA N Aluminium HSA U Stainless steel HSA M Aluminium flag with other items in stainless steel 1HSA P Stainless steel HSA V Stainless steel 62 Technical information A Surge Arresters uyer s Guide

7 Accessories rilling plans rilling plans with insulating base (4x) 14.5 (5.8 ) (6x) M16 (4x) R127 (5 ) Optional Standard 80 Ø100 Insulating base 1HSA Epoxy resin M16 bolts for connection to structure are not supplied by A. Required threaded grip length is mm. A Surge Arresters uyer s Guide Technical information 63

8 Shipping data Rated voltage Housing Number of arresters per crate One U r Volume Gross Three Volume Gross m 3 kg m 3 kg YH300 1, , YH300 1, , YV300 1, , YM362 1, , YH362 1, , YH420 1, , YV362 1, , YH420 1, , YV420 1, , YH550 3, , Each crate contains a certain number of arrester units and accessories for assembly and erection. A packing list is attached externally on each crate. Each separate crate is numbered and the numbers of all crates and their contents are listed in the shipping specification. A reserves the right to pack arresters in the most effective/economic combination. Alternate or non-standard crates may involve additional charges. The table above is to be seen as an approximation and specific data for deliveries may differ from the values given. 64 Technical information A Surge Arresters uyer s Guide

9 For more information please contact: A A High Voltage Products Surge Arresters SE Ludvika, Sweden Phone: +46 (0) Fax: +46 (0) arresters.div@se.abb.com opyright 2012 A All rights reserved NOTE: A A works continuously with product improvements. We therefore reserve the right to change designs, dimensions and data without prior notice. Section of 1HSM en High Voltage Surge Arresters uyer s Guide, Edition 9.1,

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R High Voltage Surge Arresters Buyer s Guide Section PEXLIM R Zinc Oxide Surge Arrester PEXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching

More information

Zinc Oxide Surge Arrester PEXLIM Q

Zinc Oxide Surge Arrester PEXLIM Q Zinc Oxide Surge Arrester Protection of switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages. in areas with high lightning intensity and high

More information

Zinc-Oxide Surge Arrester TEXLIM Q-C

Zinc-Oxide Surge Arrester TEXLIM Q-C Zinc-Oxide Surge Arrester TEXLIM Q-C Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. in areas with very high lightning intensity where

More information

Zinc Oxide Surge Arrester EXLIM R

Zinc Oxide Surge Arrester EXLIM R Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy

More information

Surge arrester POLIM-H..SD

Surge arrester POLIM-H..SD Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

Surge arrester POLIM-C.. HD

Surge arrester POLIM-C.. HD DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10

More information

Surge arrester POLIM-H.. ND

Surge arrester POLIM-H.. ND DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv HS PEXLIM-P Metal Oxide Surge Arrester HS PEXLIM-P Surge Arresters are used for the protection of switchgear, transformers and other

More information

Surge arrester POLIM-H..N

Surge arrester POLIM-H..N Data sheet Surge arrester POLIMH..N Technical data Arrester class SH, Station High Line discharge class (LD) 4 Nominal discharge current I n (8/20 µs) 20 ka peak Repetitive charge transfer rating Q rs

More information

High Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK

High Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK High Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK Line surge arresters PEXLINK The concept Both large and small public/private utility owners of transmission systems face a

More information

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK Definitions Transmission Line Arresters Backflashover Occurs when lightning strikes the tower structure or overhead

More information

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv POLIM-S Metal Oxide Gapless Surge Arresters POLIM-S Surge Arresters are used for the protection of switchgear, transformers and other

More information

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION HIGH VOLTAGE SURGE ARRESTER SPECIFICATION Applications: (Polymer housed MOA for 110kv) (The polymer housed MOA for 10kv) (Porcelain housed MOA for 220kv) (35kv MOA without gaps for middle phase) (110kv

More information

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4) CP9817 PAGE: 1 of 16 CERTIFIED TEST REPORT VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC 60099-4 (99-4) 0711 Supersedes 0601 Cooper Industries. All Rights Reserved. CP9817 PAGE:

More information

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3. CONTENTS About the company 4 1. Low-voltage arresters LVA type 5 2. Metal-oxide surge arresters for distribution systems. 6 2.1 PA-DM type 6 Dimensions of arresters of PA-DM 9 2.2 PA-DH types 10 Dimensions

More information

GENERAL. CONSTRUCTION External

GENERAL. CONSTRUCTION External Surge Arresters VariSTAR Type AZG4 Surge Arresters for Systems through 400 kv IEC 20-kA; Line Discharge Class 4 Electrical Apparatus I235-84 GENERAL VariSTAR AZG4 Surge Arresters incorporate the latest

More information

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide 1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK 1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

GE TRANQUELL Surge Arresters

GE TRANQUELL Surge Arresters GE Grid Solutions GE TRANQUELL Surge Arresters Product Selection Guide IEC Line Discharge Classes with 2, 3, and 4 Polymer Housings GE Surge Protection The performance and reliability of today s electric

More information

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA MCA MDA Maximum system voltage U m 420 550 System voltage U s 400 500 Nominal discharge current ka 10 20 High current impulse (4/10 µs)

More information

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3 Manufactured by: Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV-6... 150/10.3 BT-A3/8 Surge Arresters housed in polymer housing, developed to protect switchgear, over

More information

3EP6 porcelain surge arrester

3EP6 porcelain surge arrester www.siemens.com/energy/arrester 3EP6 porcelain surge arrester Safe, reliable, long-lasting, and stable Answers for energy. Compact design high mechanical stability Sealing system Spring Maximum values

More information

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA Maximum system voltage U m 800 System voltage U s 750 Nominal discharge current ka 20 High current impulse (4/10 µs) ka 100 Arrester class

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

3EK7 Medium Voltage Silicone Insulated Surge Arresters

3EK7 Medium Voltage Silicone Insulated Surge Arresters 3EK7 Medium Voltage Silicone Insulated Surge Arresters Power Transmission and Distribution Setting new Standards The 3EK7 s mechanical features: Glass-collared MOV, Silicone rubber housing, FRP rods and

More information

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge

More information

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL Surge Arresters UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 Electrical Apparatus I235-93 GENERAL UltraSIL Polymer-Housed VariSTAR

More information

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide 1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

High Voltage Surge Arresters Buyer s Guide

High Voltage Surge Arresters Buyer s Guide High Voltage Surge Arresters Buyer s Guide Table of contents Product information Introduction 3 Definitions 4 Simplified selection procedure 7 Design features - Porcelain-housed surge arresters, EXLIM

More information

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv 3EP1 Surge Arrester Metal-oxide surge arrester without series gaps for high-voltage systems up to U m = 170 kv Rated voltage up to 180 kv Nominal discharge current 10 ka, 8/20 µs Line discharge class LD1,

More information

Shielded surge arresters

Shielded surge arresters Shielded surge arresters Nexans, worldwide leader for the cable industry Total sales of billion euros in 2009 The most complete range of cables and cabling systems Plants in 39 countries 22,700 employees

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

EXCOUNT-I. User s manual

EXCOUNT-I. User s manual EXCOUNT-I User s manual Safety information Legal disclaimer Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed.

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified Surge s Catalog Data CA235022EN Supersedes TD235009EN September 2014 COOPER POWER SERIES VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified General Eaton s Cooper

More information

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide 1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Energy Division. PCA Single Column Polymeric Surge Arrester

Energy Division. PCA Single Column Polymeric Surge Arrester Energy Division PCA Single Column Polymeric Surge Arrester Bowthorpe EMP pioneered the development of the polymeric composite housed surge arrester in the early 1980 s and since 1986 has a proven service

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5 Section 204-1 204 DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5 Web: http://www.hubbellpowersystems.com E-mail: hpsliterature@hps.hubbell.com Printed in USA RGS 1M 204-2 Table of Contents Page

More information

Surge arresters Product overview

Surge arresters Product overview Surge arresters Product overview abb Surge arresters from ABB Switzerland ABB Switzerland Ltd has been developing and manufacturing for over a century, metal-oxide (MO) resistors and MO arresters for worldwide

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

Bushings for High Voltage AC Applications

Bushings for High Voltage AC Applications Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure

More information

Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014

Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014 Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014 Presented By: Steve Brewer Senior Product Manager HPS Arrester Business Unit Traveling Wave Theory/ Overvoltage Protection

More information

Station Class Polymeric Surge Arresters

Station Class Polymeric Surge Arresters The essential feature of the internal construction is the homogeneous resin and glass fibre bond over the complete insulated surface of the ZnO varistor elements. The arrester module has good conductivity

More information

Table of contents. Product information. Technical information. Other

Table of contents. Product information. Technical information. Other Contact us High Voltage Surge Arresters Buyer s Guide Document ID 1HSM 9543 12-00en, High Voltage Surge Arresters, Byuer s Guide, Edition 12, 2016-11 Table of contents Product information Introduction

More information

Surge Arresters. Supply Program. Answers for energy.

Surge Arresters. Supply Program.   Answers for energy. Surge Arresters Supply Program www.siemens.com/energy/arrester Answers for energy. Always the Best Solution We offer an extensive range of surge arresters suitable for every application economical and

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

Bowthorpe EMP LV/MV Outdoor Surge Arresters

Bowthorpe EMP LV/MV Outdoor Surge Arresters Bowthorpe EMP LV/MV Outdoor Surge Arresters Bowthorpe EMP LV/MV Surge Arresters for Outdoor Applications Table of Contents Product Classification Voltage Range Page DA Series Distribution Metal Oxide Surge

More information

GE TRANQUELLTM Surge Arresters

GE TRANQUELLTM Surge Arresters GE Digital Energy GE TRANQUELLTM Surge Arresters Product Selection & Application Guide Heavy Duty Distribution Class-Polymer and Riser Pole Polymer Arresters IEEE /ANSI C62.11 GE Surge Protection The performance

More information

MEDIUM VOLTAGE NETWORKS

MEDIUM VOLTAGE NETWORKS MEDIUM VOLTAGE NETWORKS LIGHTNING ARRESTERS & INSULATORS SICAME GROUP OUR EXPERIENCE With 25 years of experience in the field of over protection for medium lines, DERVASIL designs and manufactures zinc

More information

High Voltage Surge Arresters Station Class

High Voltage Surge Arresters Station Class Power Transmission and Distribution High Voltage Surge Arresters Station Class Product Overview High Voltage High Protection Just as the Golden Gate Bridge has successfully defied all winds, weather and

More information

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn Surge arresters UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters electrical apparatus 235-75 General Cooper Power Systems has set a new standard of excellence for polymerhoused

More information

Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks

Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks Surge Arresters Technical Data TD235026EN Supersedes November 2003 (TD-228) COOPER POWER SERIES Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks Ø40.74 ±0.41

More information

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks Surge Arresters Technical Data TD235027EN Supersedes November 2003 (TD-230) COOPER POWER SERIES Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks Ø40.74 ±0.41 0.051

More information

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.

More information

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

3EQ Composite Housed Surge Arresters

3EQ Composite Housed Surge Arresters Power Transmission and Distribution 3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters: Your

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv 06B1-E-0002 Small Space Requirement, High Reliability and Safety ー 72.5 to 145 kv GIS, SDH314/SDHa314

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3

More information

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

INTERFACE E - 5/8 MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017 INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer,

More information

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

More information

3EK7 Distribution Class Surge Arresters. Answers for energy.

3EK7 Distribution Class Surge Arresters. Answers for energy. 3EK7 Distribution Class Surge Arresters Answers for energy. Siemens at Your Service As a global leader of the electronics industries, Siemens has been active in the fields of power transmission and distribution

More information

3EK7 Distribution Class Surge Arresters. Answers for energy.

3EK7 Distribution Class Surge Arresters. Answers for energy. 3EK7 Distribution Class Surge Arresters Answers for energy. Siemens at Your Service As a global leader of the electronics industries, Siemens has been active in the fields of power transmission and distribution

More information

UltraSIL polymer-housed VariSTAR surge arresters 5 ka and 10 ka Class 1 IEC for MV systems to 36 kv

UltraSIL polymer-housed VariSTAR surge arresters 5 ka and 10 ka Class 1 IEC for MV systems to 36 kv Surge Arresters Catalog Data CA235029EN Supersedes I235-35 August 2014 COOPER POWER SERIES UltraSIL polymer-housed VariSTAR surge arresters 5 ka and 10 ka Class 1 IEC 60099-4 for MV systems to 36 kv General

More information

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. MV-CONNEX, HV-CONNEX, IXOSIL Terminations, IXOSIL MSA Slip-on Joint Boxes CABLE SYSTEMS Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. Welcome to the CABLE SYSTEMS Centre of Competence.

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3

More information

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features Surge s Electrical Apparatus 235-99 General Cooper Power Systems set the standard for design, manufacturing and delivery of polymeric distribution arresters with the UltraSIL polymerhoused arrester family.

More information

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA

More information

Surge Arresters. UltraSIL Housed VariSTAR Surge Arresters 5 ka and 10 ka Class 1 IEC for MV Systems to 36 kv FEATURES.

Surge Arresters. UltraSIL Housed VariSTAR Surge Arresters 5 ka and 10 ka Class 1 IEC for MV Systems to 36 kv FEATURES. Surge Arresters 5 ka and 10 ka Class 1 IEC 60099-4 for MV Systems to 36 kv Electrical Apparatus I235-35 General The advantages of polymer housed arresters reduced size and weight, and enhanced safety have

More information

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Table of contents 02 03 04 05 06 07 08 Disconnectors from ABB Maximum reliability and minimal maintenance Technical

More information

Transmission Porcelain Surge Arresters

Transmission Porcelain Surge Arresters Transmission Porcelain Surge Arresters ENERGY DIVISION Porcelain Surge Arresters Porcelain surge arresters are available for applications up to 400 systems. Porcelain housing designs have been used by

More information

EE 741 Over-voltage and Overcurrent. Spring 2014

EE 741 Over-voltage and Overcurrent. Spring 2014 EE 741 Over-voltage and Overcurrent Protection Spring 2014 Causes of Over-voltages Lightning Capacitor switching Faults (where interruption occurs prior to zero current crossing) Accidental contact with

More information

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability 3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability Power Transmission and Distribution 1 A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters:

More information

Metal Clad Air Insulated Switchgear

Metal Clad Air Insulated Switchgear Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system

More information

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters Section 1-1 1 Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications

More information

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. 1. SCOPE:- This specification covers the manufacture, testing and supply of 33KV 200 Amps, H.G. Fuse sets 2. The 33 KV H.G. Fuses shall be suitable

More information

power cable accessories

power cable accessories power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten

More information

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products Hi-Tech SX Full-Range Current-Limiting Fuses Provides both overload and fault current protection for distribution equipment in a single fuse body. Trans-Guard SX Full-Range Current-Limiting Fuse As a full-range

More information

Surge Arrester 3EL2 superior protection up to 550 kv

Surge Arrester 3EL2 superior protection up to 550 kv Certified according to IEC 60099-4 Edition 2.1 (2006) Surge Arrester 3EL2 superior protection up to 550 Light weight. Strong performance. Answers for energy. Simply irresistible. By resisting wear in any

More information

UltraSIL polymer-housed VariSTAR station-class surge arresters

UltraSIL polymer-housed VariSTAR station-class surge arresters Surge s Catalog Data CA235013EN Supersedes August 2015 COOPER POWER SERIES UltraSIL polymer-housed VariSTAR station-class surge arresters General Eaton has set a new standard of excellence for polymer-housed

More information

132/11 kv, 25 MVA MOBILE SUBSTATION

132/11 kv, 25 MVA MOBILE SUBSTATION File name: Mob EN katalog1 Zagreb, 11.11.2014. Page: 1 od 9 Summary Mobile substation consists of two semitrailers. One trailer is for 132 kv equipment (HV equipment) and another trailer is for medium

More information

ABB in Ludvika, Sweden. High Voltage Valley

ABB in Ludvika, Sweden. High Voltage Valley Michael Holmgren & Håkan Åkesson, ABB Sweden CIGRE colloquium Sarajevo 13-16 May 2012 ABB in Ludvika, Sweden. High Voltage Valley May 9, 2012 Slide 1 High Voltage Valley High power laboratory STRI & unique

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic

More information

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2 Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2 Table of Contents 1 Introduction... 4 2 Description of retrofit circuit-breaker 8DN8... 5 3 Technical data for retrofit circuit-breaker

More information

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester This report records the results of the design tests made on Type PDV 100 Optima Distribution

More information

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker

More information

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A Medium voltage compact switchgears rated voltage 12 and 25 kv rated current 400 and 630 A 1 General The new air-insulated DRIESCHER medium voltage compact switchgears are ideal for application in secondary

More information

Independent Testing Laboratory for High Voltage Equipment

Independent Testing Laboratory for High Voltage Equipment T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.

More information

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work GE Electrical Distribution Gerapid High Speed DC Circuit Breakers On the move imagination at work Gerapid High Speed DC Circuit Breakers To stay up and running today, you need equipment that delivers both

More information

ENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC. Bowthorpe EMP Transmission Line Surge Arresters (IEC)

ENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC. Bowthorpe EMP Transmission Line Surge Arresters (IEC) ENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC Bowthorpe EMP Transmission Line Surge Arresters (IEC) TRANSMISSION LINE SURGE ARRESTERS Numerous technical publications have stated that lightning is responsible

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected. Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

More information

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com TGOOD produces over 5000 switchgear units annually for projects around the globe SOLUTION OVERVIEW For use in affordable air insulated

More information

a Nexans company Catalogue 2008

a Nexans company Catalogue 2008 a Nexans company Catalogue 008 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage

More information

Directly Molded Polymer Surge Arresters

Directly Molded Polymer Surge Arresters Directly Molded Polymer Surge Arresters Ideal means to reduce environmental impact Up to 420kV, Comply with IEC60099-4, Line discharge class 2-4 l Long-life performance (Hydrophobic silicone rubber) l

More information

Siemens Automation. Surge arrester 3EB4. Operating instructions. Bestell-Nr.: b

Siemens Automation. Surge arrester 3EB4. Operating instructions. Bestell-Nr.: b Surge arrester 3EB4 Operating instructions Bestell-Nr.: 928 00180 176b Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication