1 Chapter 8 Interior Wiring and Lighting Review Questions 1. What tool if any, is used to remove a fuse that is to be replaced? 1. Pliers 2. Screwdriver 3. Fuse puller 4. None 2. OSHA has established specific color codes to designate certain cautions and dangers. What color is a caution for marking physical hazards? 1. Red 2. Yellow 3. Orange 4. Green 3. What class of fire occurs in wood, clothing, paper, rubbish, and other such items? 1. Class A 2. Class B 3. Class C 4. Class D 4. What class of fire occurs in electrical equipment and facilities? 1. Class A 2. Class B 3. Class C 4. Class D 5. Obtain permission from what individual prior to installation or maintenance of energized circuits? 1. Division Officer 2. Division Chief 3. Site Supervisor 4. Commanding Officer 6. What chapter of the NEC contains tables and examples? 1. Three 2. Five 3. Seven 4. Nine
2 7. What is the starting point for interior wiring? 1. Service entrance 2. Bus bar 3. Fuse panel 4. Circuit board 8. What material is usually used to make rigid metal conduit? 1. Lead 2. Copper 3. Steel (ferrous) 4. Brass 9. What size wire is most frequently used for interior wiring as a solid or stranded copper conductor? 1. Number 12 AWG 2. Number 14 AWG 3. Number 16 AWG 4. Number 18 AWG 10. When making the decision on what box to mount in each location what considerations must be made prior to choosing the box? 1. Size of room 2. Number of occupants 3. Number and size of conductor s box will contain 4. Size of conductors only 11. What tool is marked by many electricians as a guide to indicate the proper height for installing outlet boxes? 1. Screwdriver 2. Hammer handle 3. Monkey wrench 4. Pipe wrench 12. When a room is to be lit with a row of lights, they will be installed at what location in the room? 1. Along the center line 2. Along the entrance-side wall 3. Along the opposite was from entrance 4. At each end of the room 13. (True or False) An electrical system installed in concrete or in direct contact with the earth is considered to be a system below grade.
3 14. (True or False)The recognized wiring methods of the NEC do not allow use of type UF cable for interior wiring in wet, dry, or corrosive locations. 15. (True or False) Ungrounded conductors are available only as multi-conductor cables. 16. Most construction blueprints and specifications will not show what information needed for installation of a circuit? 1. Direction of the conduit run 2. Distribution panel to be used 3. Location of apparatus 4. Number of boxes per circuit 17. Conductors of more than 600 volts on a power should not occupy the same enclosure as conductors carrying less than how many volts? volts volts volts volts 18. A lighting and appliance branch circuit panelboard is limited to not over how many overcurrent devices (excluding the main overcurrent devices) in any one cabinet or cutout box? How much overcurrent protection must panelboards equipped with snap switches rated at 30 amperes or less have? 1. Not in excess of 200 amperes 2. Not in excess of 250 amperes 3. Not in excess of 300 amperes 4. Not in excess of 400 amperes 20. The total load on any overcurrent device located in a panelboard will not exceed what percent of its rating? percent percent percent percent
4 21. With the exception of fluorescent lighting, lighting branch circuits may carry loads as high as the maximum of how many amperes? amperes amperes amperes amperes 22. Once you begin the finish work, what is the first thing you need to do? 1. Turn on power to circuits 2. Install all switches 3. Install all outlets 4. Make all ground connections 23. Which answer below contains all the switches used for interior wiring? 1. Single-pole, three-way, four-way toggle switches 2. Three-way, four-way toggle, five-blade toggle 3. Single-pole and three-way only 4. Single-pole and four-way toggle only 24. What is the term for removing sharp edges or burrs on the inside of conduit after it has been cut? 1. Scraping 2. Reaming 3. Cleaning 4. Brushing 25. Most field bends are done with manual benders. What are the two types of manual benders? 1. One-shot and Hixon benders 2. One-shot and Hickey benders 3. Hickey and Hixon benders 4. Upright and One-shot benders 26. When installing rigid nonmetallic conduit, factory elbows are available in what degree bends? 1. 20, 22, and 24 degree 2. 26, 28, and 32 degree 3. 30, 45, and 90 degree 4. 35, 40, and 80 degree
5 27. When making a 90 degree bend, by what term is the distance from the end of the conduit to the back of the 90 known to electricians? 1. End of bend 2. Stub-up 3. Snub-up 4. Take-up 28. What is the definition of an offset bend? 1. Two equal bends in opposite directions 2. Two equal bends in same direction 3. One bend same direction as fixture 4. One bend opposite direction from fixture 29. What is the most common method of straddling an object with conduit? degree center bend degree offset bend 3. Three-bend saddle 4. Two-bend saddle 30. (True or False) Power benders are used for bending only small sizes of conduit? 31. (True or False) Some mechanical benders have an electrical power pump that is used to apply pressure on the ram. 32. (True or False) All raceways must be installed as a complete system before any conductors are pulled into them. 33. (True or False) Rigid metal conduit must be supported within 6 feet of a box. 34. (True or False) For short conduit runs with only two wires, the conductors can be pushed through the conduit from one box to the next.
6 35. What is the maximum number of right angle bends in conduit between outlets or fittings? 1. Two 2. Three 3. Four 4. Five 36. Fuse panels are not to be installed either for new work or as a replacement panel unless they have been modified to accept what type fuse? 1. Type J 2. Type S 3. Type T 4. Type Z 37. The NEC requires all but, which one of the following locations within a home to have ground fault circuit interrupter (GFCI) circuit breakers installed? 1. Bedrooms with no 15 or 20 ampere receptacles 2. Bathrooms with 15 and 20 ampere receptacles 3. Garages with 15 and 20 ampere receptacles 4. Outdoor patio with 15 and 20 ampere receptacles 38. (True or False) Some models of clamp on ammeter allow electricians to measure the amount of current on an energized circuit without having to open the circuit first and connect test leads. 39. (True or False) The fastest method of determining resistance is by taking a resistance reading directly from a clamp-on-ammeter. 40. (True or False) An open circuit is an incomplete circuit. 41. What is the most common test made with a neon tester? 1. Testing if a circuit breaker is good or bad 2. Checking for circuit resistance 3. Checking circuit voltage 4. Checking for power to a receptacle
7 42. What is the first step prior to testing for a defective switch? 1. Make sure the power to suspected switch has been turned OFF 2. Make sure the power to suspected switch has been turned ON 3. Make sure the suspected switch is correct size for circuit 4. Make sure there are no other switches on same circuit 43. All but which of the following are types of grounds or short circuits? 1. Fluctuating 2. Solid 3. Partial 4. Floating 44. What type of device or splice has almost completely eliminated soldering and taping for certain connections? 1. Pigtail splice 2. T-tap splice 3. Western Union splice 4. Wire nuts 45. What type of splice is used when the connection must be strong enough to support long lengths of heavy wire? 1. Pigtail splice 2. Western Union splice 3. T-tap splice 4. Portable cord splice 46. (True or False) Once the decision is made to solder an electrical splice and the insulation has been stripped of the wire, the splice should be soldered as soon as possible due to possible oxidation. 47. (True or False) Using either a soldering iron, soldering gun, or propane torch the solder should be applied to the same side of the splice as the heat. 48. (True or False) When plastic (vinyl) tape is used for insulation protection for a splice it should be stretched as it is applied.
8 49. (True or False) Mercury lamps have the best maintained light output because the electrodes operate at a relatively cool temperature. 50. How many types of prefabricated scaffolding are there? 1. One 2. Two 3. Three 4. Four 51. What are the maximum pounds per square foot that heavy duty scaffolding should handle? pounds pounds pounds pounds
CHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to
More informationSpring Test 10 due 05/11/2013
Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock
More informationAn average of one worker is electrocuted on the job every day There are four main types of electrical injuries:
Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock
More informationSTATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES
STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES Articulation Agreement Identifier: ELT 110 2005-1 Identifier is the postsecondary course prefix followed by Plan-of-Instruction version
More informationChapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9
Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6
More informationElectrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1
Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)
More informationArc Fault Circuit Interrupter (AFCI) FACT SHEET
Arc Fault Circuit Interrupter (AFCI) FACT SHEET THE AFCI The AFCI is an arc fault circuit interrupter. AFCIs are newly-developed electrical devices designed to protect against fires caused by arcing faults
More informationELECTRICAL. 60 Minutes
ELECTRICAL 60 Minutes AGENDA Electrical definitions Electrical shocks, burns and secondary injuries Electrical hazards in the workplace Safety devices and prevention steps Do s and Don ts INTRODUCTORY
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationElectrical and Power Transmission Installers, Other CIP Task Grid. Secondary Competency Task List. Level 1 Level 2 Level 3
1 100 BASIC SAFETY 101 Demonstrate proper use of personal protective equipment. 5 102 Identify causes of job site accidents. 5 103 Identify job site hazards. 5 104 Working safely with job hazards. 5 105
More informationSpring Test 7 due 05/03/2013
Spring Test 7 due 05/03/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A raceway contains two 3-phase, 3-wire circuits that supply 38 ampere continuous
More informationThe following are specific provisions of 1910(a)(2) that could be seen in the LBM sector
Know the Rules on Temporary Wiring OSHA Standard 1910.305, Wiring methods, components, and equipment for general use, addresses wiring methods, components, and equipment for general use as one of several
More informationInstalling a Downstream Distribution Panelboard
Job Sheet 5 Installing a Downstream Distribution Panelboard OBJECTIVE To install a downstream distribution panelboard (DDP) on the Mobile Workstation. To mechanically and electrically connect the DDP to
More informationContinued from Part 2 Rules
Continued from Part 2 Rules 26 50. 51 250.94 Grounding (Bonding) of Communications Systems An accessible bonding point must be provided at service equipment or the disconnecting means of separate buildings
More informationWIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST
WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors.
More informationSINGLE PHASE WIRING SPECIFICATIONS
SINGLE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More information90.2 Scope. The installation of electrical conductors, equipment and raceways for:
NEC Generator Primer Rules on the installation of generators and transfer switches 1 90.2 Scope The installation of electrical conductors, equipment and raceways for: public and private premises Conductors
More informationTHREE PHASE WIRING SPECIFICATIONS
THREE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More informationOvercurrent Protection (2014 NEC) (Homestudy)
Overcurrent Protection (2014 NEC) (Homestudy) Oregon Electrical License The key sections of Article 240 will be discussed. Overcurrent protection for panelboards, appliances, motors, motor compressors,
More informationElectrical Equipment and Terminology
Youth Explore Trades Skills Description Understanding the language of the electrical trade and knowing what electrical equipment is named and its purpose are very important. Anyone who is exposed to a
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More informationPART A General Conductor Requirements
PART A General Conductor Requirements 6.1 Conductor Insulation Property Table 310.13 of the NEC provides information on conductor properties such as permitted use, maximum operating temperature, and other
More informationPHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST
PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic
More informationWestern Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast
Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast 1.Question: An add on unit for a hydromassage bathtub consists of a small 1-gallon water heater
More informationBusway Construction. Bus Bars
Busway Construction Bus Bars A better understanding of what busway is can be gained by examining its construction. A typical Siemens Sentron busway section has three or four formed aluminum or copper bars
More informationElectrical Hazards in Construction
Electrical Hazards in Construction WELCOME Tim Dawson Presentation developed by Dawson Safety Services - 2013 Dangers of Electrical Shock Currents above 10 ma* can paralyze or freeze muscles. Currents
More informationElectrical Tech Note 105 Agricultural Engineering Department Michigan State University
Electrical Tech Note 105 Agricultural Engineering Department Michigan State University Journey Exam Study Guide and Sample Questions 1 Based on the 2002 NEC, Part 8 of PA 230, and the 2003 MRC The Journey
More informationSECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems
COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic
More informationFACT SHEET Standard: Electrical Safety
What is a Ground Fault Circuit Interrupter? FACT SHEET The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault
More information9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.
Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution
More informationInstallation Instructions: HYPERION R-Lite SYSTEM
Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read
More informationINDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE
INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH LIGHTING SYSTEMS AND OTHER ELECTRICAL EQUIPMENT All electrical systems and electrically energized equipment
More information9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC
2011 NEC Significant Changes Courtesy of NJATC Courtesy of NFPA Presented By: Michael J. Johnston Executive Director of Standards and Safety, NECA Objectives Review significant revisions in the 2011 NEC
More informationFee $20 Course: NEC Changes 1 This course is valid for these credentials: Credential Description Cred Code Credit Hours
www.garyklinka.com Page 1 of 18 Instructions: Fee $20 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms
More informationElectrical Maintenance and Repair: Introduction to Basic Electricity
Electrical Maintenance and Repair: Introduction to Basic Electricity Common Electrical Maintenance Tasks The following are common electrical maintenance tasks you will encounter. Repairs Example: Replacing
More informationNEC 2011 Code Changes
NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I recently installed a 45-KVA transformer, 480-volt primary
More informationENTRANCE EQUIPMENT ER D PAGE 1 OF 5
PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument
More informationHave You Been Grounded Lately
Have You Been Grounded Lately Thurs, Oct. 26, 2017 9:15-10:15 Phil Simmons Author, Electrical Grounding and Bonding Author Cengage Learning Phil Simmons Have You Been Grounded Lately 2017 NEC Changes Relative
More informationElectrical Tech Note 111 Biosystems & Agricultural Engineering Department Michigan State University
Electrical Tech Note 111 Biosystems & Agricultural Engineering Department Michigan State University Electrical Code Changes in Michigan 1 (Based on Part 8, P.A. 230, the 2005 NEC and the 2003 MRC) This
More informationELECTRICAL GROUNDING SAFETY PROGRAM
ELECTRICAL GROUNDING SAFETY PROGRAM PURPOSE / SCOPE The purpose of this program is to ensure the proper installation, maintenance, inspection, and testing of equipment grounding conductors on construction
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationSection 02: Pre-Installation Procedures
Section 02: Pre-Installation Procedures Foundation! WARNING The MUST be placed on a surface that will support the combined weight of the, options, fixtures, and tooling, etc. (refer to the Specifications
More information2011 NEC Code Updates Part 3
www.garyklinka.com Page 1 of 22 Instructions: Fee $35 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms
More informationELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016
UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department
More information2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying
More informationRecreation Vehicle Industry Association Inspection Program Deviations Database. Revised June 26, 2012
Recreation Vehicle Industry Association Inspection Program Deviations Database Revised June 26, 2012 Standard Subcategory (subcat.) paragraph number reference to the respective standard (deviation number)
More informationA. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.
SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems
More information2016 Photovoltaic Solar System Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE
More information2011 NEC Changes Part 2 (Homestudy) (Homestudy)
2011 NEC Changes Part 2 (Homestudy) (Homestudy) North Carolina Electrical License This course will review the second half of the most important National Electrical Code changes from the 2011 NEC. Changes
More informationCHAPTER 10 ELECTRICAL
1001.0 General Requirements. 1001.1 Electrical Wiring and Equipment. Electrical wiring and equipment shall comply with the requirements of NFPA 70, National Electrical Code (NEC), or local ordinances.
More informationElectrical Tech Note 106
Electrical Tech Note 106 Biosystems & Agricultural Engineering Department Michigan State University Master Exam Study Guide and Sample Questions 1 Based on the 2014 NEC, Part 8 of PA 230, PA 407, and the
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More informationMetering and Service Installation:
Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...
More informationPretest Module 24 Three-phase Service Entrance
Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?
More information4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.
CHAPTER 17 4 Electric Circuits SECTION Introduction to Electricity BEFORE YOU READ After you read this section, you should be able to answer these questions: What are the three main parts of a circuit?
More informationSURFACE TRACK (120/250V) SPECIFICATIONS
SURFACE TRACK (120/250V) SPECIFICATIONS GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed
More informationElectricity. 3 or 4 Member Team
Electricity 3 or 4 Member Team IMPORTANT NOTE Please read thoroughly the General CDE Rules Section at the beginning of this handbook for complete rules and procedures relevant to State FFA Career Development
More informationElectricity. 3 or 4 Member Team
Electricity 3 or 4 Member Team IMPORTANT NOTE Please read thoroughly the General CDE Rules Section at the beginning of this handbook for complete rules and procedures relevant to State FFA Career Development
More informationEasy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH
STANDBY POWER FURNACE SWITCH Easy/Tran TF Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has been manufacturing transfer switches and equipment
More informationCHAPTER 10 ELECTRICAL. Notes:
CHAPTER 10 ELECTRICAL 1001.0 General Requirements. Electrical wiring and equipment shall comply with the requirements of NFPA 70, National Electrical Code (NEC), or local ordinances. 1002.0 Solar Photovoltaic
More informationFlorham Park, NJ USA Call (ASCO) for sales or service
Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious
More informationPentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION
PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company
More informationWestern Section IAEI Code Panel Questions
Western Section IAEI 2013 Code Panel Questions 1. Do the factory wings that many fluorescent troffers have designed to fold out over the grid meet the requirements for securely fastened to the framing?
More informationTRANSMISSION SYSTEMS
TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric
More informationCONTINUING EDUCATION FOR OREGON ELECTRICIANS NEC Code Change Part 1 8 Hours
AMERICAN ELECTRICAL INSTITUTE 2017 PART 1 3 CONTINUING EDUCATION FOR OREGON ELECTRICIANS 2017 NEC Code Change Part 1 8 Hours AMERICAN ELECTRICAL INSTITUTE PO Box 31131 Spokane, WA 99223 855-780-5046 www.aeitraining.com
More informationElegance Electrician s Installation Guide
Elegance Electrician s Installation Guide CentraLite Systems, Inc. 6420 Wall St. Mobile, AL 36695 Phone: 877-466-5483 Fax: 251-607-9119 2003-2005 CentraLite Systems, Inc. Revised 10/20/2005 ELECTRICIAN
More informationSUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More informationSee Part 3 for the Introduction for Article 314
See Part 3 for the Introduction for Article 314 76 314.25 Covers and Canopies When the installation is complete, each outlet box must be provided with a cover or faceplate, unless covered by a fixture
More informationDefinitions of and have been revised. a. automatic b. nonautomatic c. none of the above d. both a and b
www.garyklinka.com Page 1 of 12 Instructions: Fee $25 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms
More information4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.
CHAPTER 1 4 Electric Circuits SECTION Introduction to Electricity BEFORE YOU READ After you read this section, you should be able to answer these questions: What are the three main parts of a circuit?
More information2014 NEC Changes Part 4
www.garyklinka.com Page 1 of 14 Instructions: Fee $25 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms
More information(The actual state exam will be closer to 50 questions in 4 hours time) Master Electrician Practice Test
(The actual state exam will be closer to 50 questions in 4 hours time) Master Electrician Practice Test 1. Accessible as applied to wiring methods means capable of being removed or exposed without damaging
More informationTheater of Operations Electrical Systems
*FM 5-424 Field Manual No. 5-424 Headquarters Department of the Army Washington, DC, 25 June 1997 Theater of Operations Electrical Systems Table of Contents List of Illustrations... xiii Tables...xiii
More informationAVOIDING ELECTROCUTION HAZARDS
Print AVOIDING ELECTROCUTION HAZARDS MODULE DESCRIPTION This module will provide information that helps you recognize and avoid common electrocution hazards in your work environment. OBJECTIVES After completing
More informationPRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)
PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire
More informationChapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)
Chapter 5 Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI) Imagine That Engineering Inc. has adopted this program for equipment
More informationFlorham Park, NJ USA Call (ASCO) for sales or service
Operator s Manual 4000 Series ATS Automatic Open-Transition Transfer Switches D design 30 230A, J design 260 600A, H-design 800 1200A, G-design 1600 4000A, F-design 4000A DANGER is used in this manual
More informationOVERHEAD SERVICE. Items to consider
OVERHEAD SERVICE Items to consider The maximum length of the service wire from the ComEd pole to the point of attachment on your residence is 150 feet, if practical. Your service wire installation must
More informationLearning Module 10: Loadcenters. 101 Basic Series
Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential
More informationPRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)
Please indicate which products and services your company can supply by checking the appropriate box(es). Check only the first box if your company can supply all of the products and services shown for this
More informationElectric Motor Controls BOMA Pre-Quiz
Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,
More informationTheater of Operations Electrical Systems
*FM 5-424 Field Manual No. 5-424 Headquarters Department of the Army Washington, DC, 25 June 1997 Theater of Operations Electrical Systems Table of Contents List of Illustrations... xiii Tables...xiii
More informationTHEATER OF OPERATIONS ELECTRICAL SYSTEMS. May 2013
TM 3-34.46 (FM 5-424/25 June 1997)/MCRP 3-17.7K THEATER OF OPERATIONS ELECTRICAL SYSTEMS May 2013 Publication of TM 3-34.46, 3 May 2013 supersedes FM 5-424, Theater of Operations Electrical Systems, 25
More informationInstallation Instructions: ACCENT SYSTEM
Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire
More informationPower Connection Kit installation instructions
Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationSOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST
SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power
More informationUnderwriters Laboratories Inc. Marking Guide. Panelboards. July 2004
Underwriters Laboratories Inc. Marking Guide Panelboards July 2004 1 Panelboards are no longer a simple assembly of switches, fuses and circuit breakers for single ampere and voltage systems. Today, there
More information2011 NEC Significant Changes Part 1 The following course will summarize many of the important changes to the NEC code.
2 PART 1 American Electrical Institute 2013 2011 NEC Significant Changes Part 1 The following course will summarize many of the important changes to the NEC code. The 2011 Code has added 3 new articles:
More informationINSTALL SERVICE- ENTRANCE SYSTEMS
SUBCOURSE EN5141 EDITION B US ARMY ENGINEER SCHOOL INSTALL SERVICE- ENTRANCE SYSTEMS INSTALL SERVICE- ENTRANCE SYSTEMS Subcourse Number EN5141 EDITION B United States Army Engineer School Fort Leonard
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationMecklenburg County Common Code Defects
Electrical Code Defects Improper Over Current Protection Code Description 310.15 Ampacities for s Rated 0 2000 Volts. (A) General. (1) Tables or Engineering Supervision. Ampacities for conductors shall
More information2014 NEC Changes (Homestudy)
2014 NEC Changes (Homestudy) Idaho Electrical License This course will review the most important National Electrical Code changes from the 2014 NEC. Changes in Articles 100 - Chapter 9 will be covered.
More informationOutdoor Power Transmission & Distribution
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards and requirements for Outdoor Power Transmission and Distribution, including but not limited to the following:
More informationMODEL H INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your unit has been carefully packaged at the factory to prevent damage during shipping.
More informationElectrical Safety. Recognizing & Controlling Hazards
Electrical Safety Recognizing & Controlling Hazards Introduction Healthcare facilities, including hospitals, physician offices, laboratoratories, dental offices and beyond are vulnerable to a variety of
More informationCAL/OSHA ELECTRICAL LOW VOLTAGE
Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 7 Purpose The purpose of this program is to prevent injuries due to electrical exposure to low voltage (less than or equal to
More information