Installation Instructions: ACCENT SYSTEM

Size: px
Start display at page:

Download "Installation Instructions: ACCENT SYSTEM"

Transcription

1 Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire installation manual. Runs that are 13-ft to 25-ft long the power connector must be connected in the middle of the strip. If the power connection cannot be made in the middle of the strip than the LED runs cannot exceed 12-ft Power supplies must be within 25-ft of the LED run. Do not exceed the maximum lengths for what the different power supplies are capable of driving. For secondary low voltage wiring use 10AWG or 12AWG Class 2 rated wire only. Using higher than 12AWG wire will result in increased voltage drop. Do not use wire nut connectors for connecting power connectors to secondary low voltage wiring. Use wire nuts to insulate only the ends of the low voltage wires. Lumificient provides product warranty only and is not responsible for installation errors. Conforms to UL STD 2108 Certified to CAN/CSA STD C22.2 NO.12 NOTE: AC and DC components are not interchangeable. RETROFITTING OF UL LISTED SIGNS E / 7BA6 E Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 1 of 14

2 The main power to any existing system must be disconnected prior to the installation. The Accent system is intended to be used for new lighting systems or as a retrofit for existing neon, fluorescent or any combination thereof. When installing retrofit systems please refer to the existing products manufacturer for proper removal guidelines. All existing system components must be removed before installation of the Accent system. All removed material must be properly disposed of to meet your federal, state and local regulations. Install in accordance with the NEC and Local Electrical Codes. Hardware Screws IDC connectors Wire nuts Class 2 low voltage wire Tools Scissors Drill Screwdriver Pliers Optional Support Clamps Silicone New Install 1. Surface must be free of dust, dirt and grease. Use non-oil based solvent (409, alcohol) to clean the surface. Area must be dry before application. The Accent strip bonds to all non-porous surfaces. Note: For porous surfaces use Accent support clamps which can be purchased from Lumificient. Note: Application temperature range: 32 F to 100 F (0 C to 38 C). Note: It is recommended to test one or more areas before installation for acceptable color and illumination. 2. Determine the linear footage required for each area to be illuminated. Do not precut LED strips. Group runs into equal load groups not to exceed the maximum footage allowed for the power supply you are using. The power supply should be located within 25-ft of the LED strip. Please contact Lumificient if the power supplies need to be located more than 25-ft away from the runs. Note: Accent comes in 12.5-ft and 25-ft sections, so before beginning your application it is recommended that you review your plans and layout longer runs first. Please follow layout diagrams and if needed consult with a Lumificient representative. By doing this you will maximize the strip and limit the need for added components. 3. Expose approximately 6 inches of the adhesive backing. Note: Do not touch adhesive tape with greasy or wet hands! Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 2 of 14

3 4. Adhere the Accent strip inch by inch to surface. Note: It may take some time for the adhesive to bond to the surface (24-48 hours). In case of poor adhesion of the strip you may use the plastic support clamps or silicone to secure strip to surface. ( Attachment 2) 5. To make a curve, bend the Accent flexible conductor strip between the sockets pinching excess strip between thumb and forefinger together. After pinching adhere corner of the turn by firmly pushing down with your forefinger. Note: Do not put support clamps over any bends in the strip ( Attachment 2). 6. To trim Accent strip to desired length, cut strip with scissors directly between sockets. Note: Do not make cuts near any socket. Do not use wire cutters or utility knives to trim the strip. Doing so may cause permanent damage to the strip! Installing Power Connector (Dry or Damp Locations Only) For LED runs that are 13-ft to 25-ft long the power connector must be connected in the middle of the strip. If the power connection cannot be made in the middle of the strip than the LED runs cannot exceed 12-ft Note: Do not exceed the maximum loads for what the different power supplies are capable of driving. See power supply tables for minimum and maximum loads. For better power distribution, group runs into equal load groups. 1. Unplug the LED module from the socket. To remove the LED module, place thumb and forefinger on side edges of LED module and pull directly upwards until LED module is released from the socket. 2. With thumb and forefinger at base of the connector and aligned parallel with the strip, place connector pins into socket and lightly push down on top of connector with forefinger until the connection is secure. 3. Plug in previously unplugged LED module to the top of the power connector. Note: Do not tug on connector leads. 4. Secure the connector with the connector holder and secure the connector cable with a 1/4 wire clamp ( Attachment 1). Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 3 of 14

4 Installation of Jumper Connector Some applications require multiple strips of Accent. In cases like this use the jumper connector to connect two separate runs as shown in picture below. Connect the jumper in the best possible area trying to avoid tight areas or severe bending or stretching of jumper. Please plan ahead when using multiple jumper connectors during installation. Note: The runs must be within 6 inches of each other as the jumper connectors are only 8 inches in length. Note: Each jumper counts as 1-ft of LED strip and must be factored into the total footage of the power supply. 1. Attach one end of the jumper anywhere on the LED strip and secure with connector holder. 2. Attach the other end of the jumper to separate LED strip and secure with connector holder. Secure all wires with a 1/4 selfadhesive clamp. ( Attachment 1) Note: The joined LED runs MUST NOT exceed a combined total of 11 feet. Note: Only one jumper connector can be used per power connector. Using more than one jumper connector per power connector will result in voltage drop Attachment 1 Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 4 of 14

5 Installation of Support Clamp Attachment 2 Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 5 of 14

6 HRLA-24 Power Supply Installation All secondary wiring must comply with Article 725 of the 2002 National Electrical Code (NEC). Class 3 or PLTC wire can be used as a substitution of Class 2 wire. Please refer to NEC Cable Substitution Hierarchy. HRLA Group runs into equal load groups not to exceed the maximum load as listed in the Power Supply Loading Guidelines ( Table 1). The power supply should be placed within 25-ft of the LED strip. Should you be required to locate the power supply further away please consult with your Lumificient representative. 2. Place the power unit in the middle of the selected load group as shown in the schematic drawing in attachment 3. Run a pair of Class 2 rated wires the length of the selected load group ( Attachment 3). Note: Longer runs of 12AWG secondary wiring will decrease maximum allowable linear footage. Note: Using higher than 12AWG wire will result in increased voltage drop. 3. Connect power connector leads to Class 2 rated wires (parallel electrical connection) by using tap and run IDC connectors. Note: Do not use wire nuts for connecting power connectors to Class 2 rated wires! 4. Use wire nuts to insulate ONLY the ENDS of the Class 2 wires. Secure Class 2 rated wires on the wall with wire clamps. Note: All free hanging wire must closely follow the building structure and must be supported by wire clamps every 4.5-ft and at least 1-ft from the power unit. 5. Connect secondary/output wires from the HRLA-24 power unit to Class 2 rated wires by using tap and run IDC connectors ( Attachment 3). Important: Maximum load is 15 linear feet per power unit. Note: Do not connect power supply outputs in series or parallel! 6. Secure power unit inside of electrical enclosure. Note: For wet locations, HRLA-24 power unit must be installed in NEMA 3R enclosure. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). Note: For dry or damp locations, HRLA-24 power unit must be installed in NEMA 1 rated enclosure OR inside of all metallic enclosure. Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 6 of 14

7 7. Connect the power unit to 120VAC junction box. Note: It is required to use UL rated metallic or nonmetallic conduit between the junction box and the power supply enclosure. Caution: Have a licensed electrician connect primary. Note: High voltage primary wiring, including wiring within 120VAC junction box, should comply with any applicable grounding and bonding requirements in Article 600 of the 2005 National Electrical Code (NEC). Verify if disconnect switch is present. National Electrical Code (NEC) requires a disconnect switch. If disconnect switch is not present, it must be installed between the main breaker and the first power unit. 8. Test the runs by turning the main power on. Note: Do not touch any metal parts while testing. Please refer to the Typical Layouts document for examples of installations. Note: AC and DC components are not interchangeable. Table 1: Power Supply Loading Guidelines HRLA-24 Power Supply Outputs Output Voltage Minimum Linear Footage Maximum Linear Footage HRLA VAC nom. No minimum 15 linear feet Attachment 3 Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 7 of 14

8 HRLA-SQ25 Power Supply Installation All secondary wiring must comply with Article 725 of the 2002 National Electrical Code (NEC). Class 3 or PLTC wire can be used as a substitution of Class 2 wire. Please refer to NEC Cable Substitution Hierarchy. HRLA-SQ25 1. Group runs into equal load groups not to exceed the maximum load as listed in the Power Supply Loading Guidelines ( Table 2). The power supply should be placed within 25-ft of the LED strip. Should you be required to locate the power supply further away please consult with your Lumificient representative. 2. Place the power unit in the middle of the selected load group as shown in the schematic drawing in attachment 4. Run a pair of Class 2 rated wires the length of the selected load group ( Attachment 4). Note: Longer runs of 12AWG secondary wiring will decrease maximum allowable linear footage. Note: Using higher than 12AWG wire will result in increased voltage drop. 3. Connect power connector leads to Class 2 rated wires (parallel electrical connection) by using tap and run IDC connectors. Note: Do not use wire nuts for connecting power connectors to Class 2 rated wires! 4. Use wire nuts to insulate ONLY the ENDS of the Class 2 wires. Secure Class 2 rated wires on the wall with wire clamps. Note: All free hanging wire must closely follow the building structure and must be supported by wire clamps every 4.5-ft and at least 1-ft from the power unit. 5. Connect secondary/output wires from the HRLA-SQ25 power unit to Class 2 rated wires by using tap and run IDC connectors ( Attachment 4). Important: Minimum load per power unit is 5 linear-ft, maximum load 25 linear-ft Note: Do not connect outputs in series or parallel! 6. Secure power unit on the wall with three screws. Note: For wet locations, HRLA-SQ25 power unit must be installed in NEMA 3R enclosure. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 8 of 14

9 7. Connect the power unit to 120VAC junction box. Note: HRLA-SQ25 is equipped to accept 120VAC, 230VAC OR 240VAC ( see Attachment 5 for wiring diagram). Caution: Have a licensed electrician connect primary. Proper connection is as follows: a) For 120VAC: Hot to Black & Yellow; Neutral/Common to Orange & White; DO NOT Connect BROWN and insulate end separately; Green: Ground. b) For 230VAC: Hot to BROWN; Neutral/Common to Orange; White & Yellow connected and insulate ends; DO NOT Connect BLACK and insulate end separately; Green: Ground. c) For 240VAC: Hot to BLACK; Neutral/Common to Orange; White & Yellow connected and insulate ends; DO NOT Connect BROWN and insulate end separately; Green: Ground. Note: It is required to use UL rated metallic or nonmetallic conduit between the junction box and the power supply enclosure. Note: High voltage primary wiring, including wiring within 120VAC junction box, should comply with any applicable grounding and bonding requirements in Article 600 of the 2005 National Electrical Code (NEC). Verify if disconnect switch is present. National Electrical Code (NEC) requires a disconnect switch. If disconnect switch is not present, it must be installed between the main breaker and the first power unit. 8. Test the runs by turning the main power on. Note: Do not touch any metal parts while testing. Please refer to the Typical Layouts document for examples of installations. Note: AC and DC components are not interchangeable. Table 2: Power Supply Loading Guidelines HRLA-SQ25 Power Supply Outputs Output Voltage Minimum Linear Footage Maximum Linear Footage HRLA-SQ VAC nom. 5 linear feet 25 linear feet Attachment 4 Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 9 of 14

10 Attachment 5 Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 10 of 14

11 HRLA-96 Power Supply Installation All secondary wiring must comply with Article 725 of the 2002 National Electrical Code (NEC). Class 3 or PLTC wire can be used as a substitution of Class 2 wire. Please refer to NEC Cable Substitution Hierarchy. HRLA Group runs into equal load groups not to exceed the maximum load as listed in the Power Supply Loading Guidelines ( Table 3). The power supply should be placed within 25-ft of the LED strip. Should you be required to locate the power supply further away please consult with your Lumificient representative. 2. Place the power unit between the two selected load groups as shown in the schematic drawing in the attachment ( Attachment 6). Run a pair of Class 2 rated wires the length of the selected load group ( Attachment 6). Note: Longer runs of 12AWG secondary wiring will decrease maximum allowable linear footage. Note: Using higher than 12AWG wire will result in increased voltage drop. 3. Connect power connector leads to Class 2 rated wires (parallel electrical connection) by using tap and run IDC connectors. Note: Do not use wire nuts for connecting power connectors to Class 2 rated wires! 4. Use wire nuts to insulate ONLY the ENDS of the Class 2 wires. Secure Class 2 rated wires on the wall with wire clamps. Note: All free hanging wire must closely follow the building structure and must be supported by wire clamps every 4.5-ft and at least 1-ft from the power unit. 5. Connect secondary/output wires to power unit terminals 1 and 2 ( Attachment 6). Note: For better power distribution divide load between terminals 1 and 2. Each terminal must be balanced within 10 linear feet of each other. Important: Minimum load per terminal is 10 linear ft., maximum load 35 linear ft. Note: Do not connect outputs in series or parallel! 6. Secure power unit with four screws. Note: For wet locations, HRLA-96 power unit must be installed in NEMA 3R enclosure. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 11 of 14

12 7. Connect the power unit to 120VAC junction box. Caution: Have a licensed electrician connect primary. Note: HRLA-96 is equipped to accept 120VAC OR 240VAC ( see Attachment 7 for wiring diagram). Proper connection is as follows: a) For 120VAC: Hot to Black & Yellow; Neutral/Common to Orange & White; Green: Ground. b) For 240VAC: Hot to Black; Neutral/Common to Orange; White & Yellow connected and insulate ends; Green: Ground. Note: HRLA-96 power unit has a cutout for 1/2 conduit fitting. It is required to use UL rated metallic or nonmetallic conduit between the junction box and the power supply enclosure. Note: High voltage primary wiring, including wiring within 120VAC junction box, should comply with any applicable grounding and bonding requirements in Article 600 of the 2005 National Electrical Code (NEC). Verify if disconnect switch is present. National Electrical Code (NEC) requires a disconnect switch. If disconnect switch is not present, it must be installed between the main breaker and the first power unit. 8. Test the runs by turning the main power on. Note: Do not touch any metal parts while testing. Please refer to the Typical Layouts document for examples of installations. Note: AC and DC components are not interchangeable Table 3: Power Supply Loading Guidelines HRLA-96 Power Supply Outputs Output Voltage Minimum Linear Footage Per Terminal Maximum Linear Footage Per Terminal Total Linear Footage HRLA VAC nom. 10 linear feet 35 linear feet 70 linear feet Attachment 6 Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 12 of 14

13 Attachment 7 Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 13 of 14

14 Troubleshooting Issue Solution All runs are off Some runs are off Some LED s appear dim or intermittent Shadows/ uneven lighting Check circuit breaker and AC input connection. Check power supply output connections and re-settable breakers (if applicable). Check IDC connectors to ensure they are fully connected. Check power lead wire connections on strip and verify connections are secure (see Attachment 1). Measure Accent strip length to ensure the maximum load length has not been exceeded. Be sure each jumper has been included in the overall footage for the power supply. Properly terminate the supply wire connection(s). Check IDC connectors to ensure they are fully connected. Check power supply output connections and re-settable breakers (if applicable). Check power lead wire connections on strip and verify connections is secure (see Attachment 1). Measure Accent strip length to ensure the maximum load length has not been exceeded. Be sure each jumper has been included in the overall footage for the power supply. Check IDC connectors to ensure they are fully connected. Check power supply output connections and re-settable breakers (if applicable). Measure Accent strip length to ensure the maximum load length has not been exceeded. Make sure the supply wire has not exceeded the maximum length of 25-ft for remote mounting. Make sure supply wire is not higher than 12AWG. Verify the max load length has not been exceeded and that wire connections and terminations are good. Re-route connecting wire and secure with wire clamps to ensure wire does not cover any of the LEDs. Copyright 2016 Revolution Lighting. All rights reserved. IN065_01_ Page 14 of 14

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM Installation Instructions: ACCENT HIGH OUTPUT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS

More information

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read

More information

SloanLED THINLED. Constant Current. Installation Guide

SloanLED THINLED. Constant Current. Installation Guide SloanLED THINLED Constant Current Installation Guide Product covered in this guide: ThinLED CC: Part Number Description 701228-18-A Amber ThinLED Constant Current 701228-18-B Blue ThinLED Constant Current

More information

WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved

WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill Components: 1. 1 AWG (0.2mm) Wire-UL Approved *Under certain conditions, a heavier gauge wire may be necessary. 2. General

More information

PDX and PX Retrofit Series

PDX and PX Retrofit Series UNIQUE LIGHTING SOLUTIONS PDX and PX Retrofit Series PDX1-1-12-XX PX1-1-12-X-X-XX-65 RETROFIT INSTALLATION GUIDE PDX and PX Series Retrofit WARNING -Retrofit installation must only be performed by a licensed

More information

G2.1 RETROFIT LED LIGHTING

G2.1 RETROFIT LED LIGHTING INSTALLATION INSTRUCTIONS FOR CHEVRON CANOPY: G2.1 RETROFIT LED LIGHTING Please review site plans before proceeding. Contact LSI Graphic Solutions Plus Customer Service at 1-(800) 678-2001 for installation

More information

Installation Instructions: Eco Linear High Bay

Installation Instructions: Eco Linear High Bay Installation Instructions: Eco Linear High Bay Installation Notes & Precautions: Read all precautions, warnings, instructions contained in this document. These instructions can be used to install Eco Linear

More information

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide Installation Guide Volt Tetra minimax LED Lighting System GEMMRD-W, GEMMGL-W, GEMMBL-W BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK Turn

More information

LumaFilm Light Emitter Installation Instructions

LumaFilm Light Emitter Installation Instructions LumaFilm Light Emitter Installation Instructions (Supplement) These Instructions are intended to be used as an installation guide to be completed by, or under the direction of a qualified electricians

More information

The Gallery System DIRECTIONS. Components of the System

The Gallery System DIRECTIONS. Components of the System The Gallery System Components of the System DIRECTIONS NOTE: The Gallery Lighting System now includes a sophisticated Junction Box with circuit breakers which will automatically switch the system off if

More information

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices. 5 YEAR WARRANTY 5 YEAR WARRANTY COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS E354088 LISTED AC E354088 58VDC E354088 E354088 5 5 YEAR WARRANTY 5 YEAR WARRANTY E354088 Caution: Observe precautions for

More information

www.greenelectricalsupply.com 1x4 2x2 & 2x4 Read all instructions and warnings before attempting installation. RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES

More information

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Installation Instructions: External-Driver SEP T8 LED Tube Lamp Installation Instructions: External-Driver SEP T8 LED Tube Lamp Installation Notes & Precautions: External-Driver SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.

More information

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product. Tetra Contour LS LED Lighting System GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1 Installation Guide 24 Volt BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT

More information

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps Installation Notes & Precautions: Memory-Dimmable SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

Assembly Instructions Retrofitting

Assembly Instructions Retrofitting Assembly Instructions Retrofitting These instructions are for replacing existing lighting fixtures or systems with our new, higher efficiency TLS, drivers and controls. www.tls-lumisign.com 514-858-6556

More information

VITALink Taped Splice Pigtail Crimp

VITALink Taped Splice Pigtail Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice

More information

Universal Retrofit System Installation Instructions Revised:

Universal Retrofit System Installation Instructions Revised: Universal Retrofit System Installation Instructions Revised: 20150624 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to

More information

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable. 5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL Exterior Cutout TILE Exterior TILE Jumper Cable T-Cable End Cap Cable Clamp Power Supply Control Module Waterproof

More information

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS Ultra Performance LED Tube Installation Instructions Page 1 of 7 ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS These instructions do not purport to cover all details or variations in components

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS 1. 2. 3. 4. DESCRIPTION: Security Light Kit APPLICATION: Altima Coupe and Sedan (2011+) PART NUMBER: 999F4 AX008 - Universal Security Lighting Kit. KIT CONTENTS:

More information

ThermoLite 40W Solar Panel Installation Instructions

ThermoLite 40W Solar Panel Installation Instructions ThermoLite 40W Solar Panel Installation Instructions INSTALL APPLICATIONS SUPPORTED BY THIS GUIDE: 1. Heat King (all models) 40W 2. Precedent Domestic Rail Container (DRC front skin mounted) 40W 3. Tractor

More information

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A 99-16999-0000 Table of Contents 1. Removing Fluorescent Lighting... 4 1.1. Detach the lens assembly... 4 1.2. Remove

More information

Technical Installation Manual

Technical Installation Manual Lighting Step and Aisle Safety Lighting Technical Installation Manual 1 Contents Page 3 Tools required 4 Installation detail & planning 5 Adhesives, silicone & crimps 6 General cinema layout 7 Basic wiring

More information

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency

More information

Optimax Pro Retrofit Instructions

Optimax Pro Retrofit Instructions Copyright 2011 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless otherwise noted. No part

More information

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: This Product is Listed by UNDERWRITERS LABORATORIES INC. and Bears the Mark: This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: SLATER SCD Installation Instructions For Self-Contained

More information

SCION xd INTERIOR LIGHTING UPGRADE Preparation

SCION xd INTERIOR LIGHTING UPGRADE Preparation Preparation Part Number: PTS21-52085 Light Guide Kit Contents Item # Quantity Reqd. Description 1 1 Controller Board, 4 color programmed w/ Bracket 2 1 RGB, LED Engine wire harness 3 2 14mm Light Rod,

More information

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by: 1/19/2012 Fluorescent 1450-3000 Lumens Works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting Maintains illumination of one or two lamps

More information

RibbonFlex Pro LED Accent Lighting White LED Tape Light. Welcome to RibbonFlex Pro LED Tape Lighting. Notes:

RibbonFlex Pro LED Accent Lighting White LED Tape Light. Welcome to RibbonFlex Pro LED Tape Lighting. Notes: RibbonFlex Pro LED Accent Lighting White LED Tape Light 30 White LEDs per meter (9 LEDs per foot) Model # RF3528030 rev 01.14 Welcome to RibbonFlex Pro LED Tape Lighting Ultra thin and flexible, RibbonFlex

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color

More information

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS MONORAIL KITS PENDANTS JESCO Lighting Group is a UL and ETL listed company Copyright 2011 JESCO Lighting Group. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS Be sure to read and unsderstand the following

More information

Installation Instructions Studio Makeup Station

Installation Instructions Studio Makeup Station Installation Instructions Studio Makeup Station 30" and 36" Models 5-light 30" Studio Makeup Station 8-light 30" Studio Makeup Station 6-light 36" Studio Makeup Station 9-light 36" Studio Makeup Station

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

SECTION 300 OVERHEAD SERVICE

SECTION 300 OVERHEAD SERVICE SECTION 300 OVERHEAD SERVICE 300.01 General Company provides, installs, and maintains service drop to point of delivery approved by Company. Customer provides point of attachment which is acceptable to

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices.

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices. 5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-4 FIT-3 FIT-2 TILE EXTERIOR FIT-1 POWER SUPPLY AC T-CABLE END CAP CONTROL MODULE CONNECTOR CAP Caution:

More information

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY!

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY! R I G I D L E D L A S E R T M / L E O N L E D S I M U L AT E D N E O N T M 2 4 L I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY! 185-1976 Philips Advance 100W 24V LOW VOLTAGE

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Model LA 4400 Time Delay OFF Controller

Model LA 4400 Time Delay OFF Controller ISIMET LA Series Model LA 4400 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller with integral 24-hr. programmable time clock operates

More information

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/ LED LINEAR INSTALLATION GUIDE RED 20L VER. 1.0 3/13/17 918.622.4978 www.lektroninc.com sales@lektroninc.com GETTING STARTED CONTENTS Following these few simple steps will ensure a successful installation

More information

ChargePoint Gateway Installation Instructions

ChargePoint Gateway Installation Instructions ChargePoint Gateway Installation Instructions You must be a licensed electrician and complete online training (http://chargepointuniversity.netexam.com/) to become a ChargePoint Certified Installer, and

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS 1. 2. 3. 4. DESCRIPTION: Security Light Kit APPLICATION: Altima Sedan (2013+) PART NUMBER: 999F4 AX010 - Universal Security Lighting Kit. KIT CONTENTS: Item QTY

More information

LED Recessed Troffer Retrofit Kit

LED Recessed Troffer Retrofit Kit Model # TRK series LED Recessed Troffer Retrofit Kit Installation Instructions PACKAGE CONTENTS A B E Part Item Name Qty. A Retrofit assembly 1 B Bracket 2 C Sheet metal screw 4 D Wire nuts 5 E Gap channel

More information

Installation Manual. CS9300 Professional Series Landscape Lighting System

Installation Manual. CS9300 Professional Series Landscape Lighting System Installation Manual CS9300 Professional Series Landscape Lighting System CS9300 Professional Series Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION! Congratulations

More information

LM79 LM80 L70:5+ YEARS

LM79 LM80 L70:5+ YEARS 1.30.18 Want to make your shop Highly Efficient, too? Reduce install mistakes and improve efficiency by transforming your shop with our 24volt System. With our 24volt PhxNRG MODULES, our 24volt PhxNRG

More information

INSTALLATION INSTRUCTIONS TRAILER HITCH MAIN HARNESS KIT

INSTALLATION INSTRUCTIONS TRAILER HITCH MAIN HARNESS KIT PART NUMBER: 0000-89-N30 GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS TRAILER HITCH MAIN HARNESS KIT APPLICABLE MODELS: 2016 > CX-9 PACKAGE CONTENTS: INSTALLATION INSTRUCTIONS QTY 1 CABLE TIE MOUNT QTY

More information

Model LA 4100 Time Delay OFF Controller

Model LA 4100 Time Delay OFF Controller ISIMET LA Series Model LA 4100 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller operates as a single output controller where the application

More information

SAVE THESE INSTRUCTIONS!!

SAVE THESE INSTRUCTIONS!! IMPORTANT: Please read carefully before installation and retain for future reference To prevent possible shock hazard, the fixture should be installed by a qualified licensed electrician All electrical

More information

Installation and Service Manual

Installation and Service Manual RESIDENTIAL PLATFORM LIFTS RPL400 / RPL600 Installation and Service Manual WARNING! STRICT ADHERENCE TO THESE INSTALLATION INSTRUCTIONS IS REQUIRED to promote the safety of those installing this product,

More information

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908 DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS

More information

Temporarily Approved Solar Photovoltaic System Electrical Schematics

Temporarily Approved Solar Photovoltaic System Electrical Schematics March 20, 2019 Page 1 of 10 Temporarily Approved Solar Photovoltaic System Electrical Schematics This document is intended as a temporary interpretation of approved solar photovoltaic electrical schematics

More information

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards 049-289 Sure-Lites Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. WARNING Risk of Fire/Electric Shock If not qualified, consult an electrician. WARNING Risk

More information

Compressor Duty Motor - 1 HP. Model 40132

Compressor Duty Motor - 1 HP. Model 40132 Compressor Duty Motor - 1 HP Model 40132 Assembly and Operating Instructions 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our web site at http://www.harborfreight.com Copyright 2002 by Harbor Freight

More information

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

Installation Manual CS9300-LED. Professional Series Landscape Lighting System Installation Manual CS9300-LED Professional Series Landscape Lighting System CS9300 Professional Series LED Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION!

More information

Chapter 8 Interior Wiring and Lighting

Chapter 8 Interior Wiring and Lighting Chapter 8 Interior Wiring and Lighting Review Questions 1. What tool if any, is used to remove a fuse that is to be replaced? 1. Pliers 2. Screwdriver 3. Fuse puller 4. None 2. OSHA has established specific

More information

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation Installation Guide WARNINGS Read all instructions and warnings before attempting installation ALWAYS MAKE ABSOLUTELY SURE THE POWER IS OFF WHEN PERFORMING THE FIXTURE MODIFICATION. DURING INSTALLATION,

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS 1. 2. 3. 4. DESCRIPTION: Accent light Kit APPLICATION: Infiniti JX (2013) PART NUMBER: 999F3 YY000 - Universal Accent Lighting Kit. KIT CONTENTS: Item QTY Description

More information

Model LA 4300 Time Delay OFF Controller

Model LA 4300 Time Delay OFF Controller ISIMET LA Series Model LA 4300 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller operates as a single output controller where the application

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

UNPACK AND IDENTIFY THE FOLLOWING PARTS. SUT-250-M2 ASSEMBLY REQUIREMENTS *Torque all T-bolt nuts to 35-40 foot pounds. *Check all lights before towing. *Tire pressure not to exceed recommendation on serial tag. *Re-torque wheel nuts after first

More information

ALL PURPOSE CNC/HEAVY DUTY

ALL PURPOSE CNC/HEAVY DUTY ALL PURPOSE CNC/HEAVY DUTY Rotary Phase Converters 240 & 480 VOLT SERIES Rotary Phase Con verter Operation & Installation Manual MTPC-RB-208.240-1P-10HP-3P DANGER: HIGH VOLTAGE Electric shock could result

More information

Parts and Accessories Installation Instructions

Parts and Accessories Installation Instructions Parts and Accessories Installation Instructions Installation kit, sound module MINI (R5) Cooper S (R53) Left-hand drive (LHD) Not suitable for vehicles with option SA 69 (navigation system with on-board

More information

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables Power Connection Kit Installation Instructions Terminator DP-M for use with TEK and HTEK series constant watt heating cables For Power Connection (1 Cable), In-Line Splice Connection, or End Termination

More information

HPNLS-HO. Installation Manual

HPNLS-HO. Installation Manual Installation Manual WARNING: Do not lift fixture by cables. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or putting undue pressure

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TIMER/CONTROLLER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TIMER/CONTROLLER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TIMER/CONTROLLER MODEL 6Tc DRAWING NUMBERS AD717BO EL530 MANUAL NUMBER IOM-002 REVISION Rev. E, 08/11/2015 TABLE OF CONTENTS SAFETY 3 1. PRODUCT INFORMATION

More information

COLD WEATHER START KIT Platinum Mini Split

COLD WEATHER START KIT Platinum Mini Split COLD WEATHER START KIT Platinum Mini Split Cold Weather Start Kit: To be used in conjunction with Platinum Mini Split cooling system. The Coolest Thing In Wine Storage LASS.MPS 051515 Conforms to ANSI/UL

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 AQUALUMIN III NICHELESS POOL LIGHT INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS DESCRIPTION The JBS-100-A and JBS-100-A6 are NEMA 4X-rated power connection kit. It is designed for use with Raychem

More information

Toyota 4RUNNER With/MR Overhead Video

Toyota 4RUNNER With/MR Overhead Video Toyota 4RUNNER With/MR 2010-10.2 Overhead Video Part Number: 00016-00110; Fit Kit-00110-14, Beige 00016-00120; Fit Kit-00120-14, Gray Accessory Code: ED7 Conflicts: Vehicles without a sunroof Kit Contents:

More information

If technical support is required, please contact Advent Technical Support at

If technical support is required, please contact Advent Technical Support at Document 128-9015A Created 12/12/11 Kit Contents: Item # Qty. Component Description 1 2 Headrest Assembly 2 2 Cables # 3 3 1 Power Cord # 9 4 1 FM Antenna 5 1 Control Box 6 2 IR Headphones 7 2 Remote Control

More information

ONE TOUCH CONTROL BOX

ONE TOUCH CONTROL BOX ONE TOUCH CONTROL BOX CONVERSION KIT INSTRUCTIONS REMOVAL, INSTALLATION, OPERATION, AND REMOTE CONTROL PROGRAMMING THUNDERSTONE PART #101322 REVISION A JULY 14 TH 2016 2 P a g e INSTALLING THE THUNDER

More information

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001 This chapter contains these topics: Safety Warnings, page 1 Box Contents, page 3 Installation Guidelines, page 6 Mounting the Switch, page 8 Installing the Power Cord Retainer, page 63 10/100 Port Connections,

More information

SLIMFLEX LED Tape Lighting

SLIMFLEX LED Tape Lighting 1 SLIMFLEX LED Tape Lighting Installation Guide BEFORE YOU BEGIN, READ INSTALLATION INSTRUCTIONS THOROUGHLY Install in accordance with the National Electric Code and local regulations This product is intended

More information

INSTRUCTIONS. Power Panel. Installation Instructions

INSTRUCTIONS. Power Panel. Installation Instructions Overview LuXout Shade 18 Output - For use with LuXout Shades NOTICE: This power supply is built-in fan on/off control circuit. Fan automatically works according to working temperature. SHOCK HAZARD Risk

More information

LightRider. Instructions for Power Link Helmet Light. Helmet Vertical Midline

LightRider. Instructions for Power Link Helmet Light. Helmet Vertical Midline LightRider Instructions for Power Link Helmet Light Helmet Vertical Midline Look at the back of your helmet. Then imagine a vertical line that runs up the back and divides your helmet into right and left

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS 1. 2. 3. 4. DESCRIPTION: APPLICATION: PART NUMBER: KIT CONTENTS: Accent light Kit Versa Note 999F3 4Z000 - Accent Lighting Kit. 999Q9 AY000 - Accessory Service Connector

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS 1. 2. 3. DESCRIPTION: APPLICATION: PART NUMBER: Accent light Kit Cube (MY2013+) 999F3 AW000 - Universal Accent Lighting Kit. 4. KIT CONTENTS: Item QTY Description

More information

ThermoLite 110W-330W Solar Panel Installation Instructions

ThermoLite 110W-330W Solar Panel Installation Instructions ThermoLite 110W-330W Solar Panel Installation Instructions INSTALL APPLICATIONS SUPPORTED BY THIS GUIDE: 1. Trailer Roof Top Mounted 2. Bus Roof Top Mounted 3. Tractor Fairing Mounted 40W and 110W Replacement

More information

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA LED LINEAR AMBER 20L INSTALLATION GUIDE VER. 1.0 9/01/16 www.lektroninc.com 918.622.4978 CERTIFIED SAFETY US CA GETTING STARTED CONTENTS Following these few simple steps will ensure a successful installation

More information

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit GE Industrial Solutions DET-809 Installation Instructions AMP1N4 Enclosure for AMP1 Series Energy Meters with Swing Panel Kit Safety FCC PART 15 INFORMATION NOTE: This equipment has been tested by the

More information

UL AND CODE COMPLIANCE

UL AND CODE COMPLIANCE BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency

More information

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: 30A EVoCharge EVSE Model Number: EV072-300-001A Product Safety Certification: UL and cul Listed Description: SAE J1772 AC Level

More information

AUTOMATIC DUST COLLECTION FOR SMALL SHOPS INSTRUCTIONS GG500C MOTOR CONTACTOR WITH THERMAL PROTECTION 220VAC COIL

AUTOMATIC DUST COLLECTION FOR SMALL SHOPS INSTRUCTIONS GG500C MOTOR CONTACTOR WITH THERMAL PROTECTION 220VAC COIL AUTOMATIC DUST COLLECTION FOR SMALL SHOPS INSTRUCTIONS GG500C MOTOR CONTACTOR WITH THERMAL PROTECTION 220VAC COIL Thank you for choosing our Automatic Dust Collection System. We at Grngate have developed

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation Preparation Part Number: PT942-02140 Kit Contents Item # Quantity Reqd. Description 1 1 Illuminated Scuff plate, Front Right Hand 2 1 Illuminated Scuff plate, Front Left Hand 3 1 Door Scuff plate, Rear

More information

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2

More information

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN Installation,Operation and Maintenance Manual PN 750-0098-001 CurrentGuard CurrentGuard Plus Surge Protective Devices CurrentGuard CurrentGuard and CurrentGuard Plus Installation, Operation and Maintenance

More information

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series: MAPA Products MPD-XX / Pedestal Disconnect 30, 60, 100 amp February 2014 Pedestal Disconnect Installation Instructions Parts List MAPA Products Fusible Rainproof Pedestal Mounted Safety Switch provides

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS 99-24283-I001 Table of Contents 1. 24V LED Approved Drivers 5 1.1. 24V LED Driver (60-19910-0002).. 5 2. Optimax Radiant 24V LED Lighting. 6 2.1. OP30 6 2.2.

More information

Quarter Master Series 94 Actuator

Quarter Master Series 94 Actuator Quarter Master Series 94 Actuator Installation, Operation and Maintenance Manual Assembly Series 94 Manual Rev V 9/5/13 Page 1 of 12 Table of Contents Series 94 Electric Actuator Introduction... 3 Description...

More information

* * APPLICABLE MODELS: 2014 > Mazda 3

* * APPLICABLE MODELS: 2014 > Mazda 3 PART NUMBER: 0000 8C L48 (DIO) / 0000 89 L84 (PIO) GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS Rev. AAA *550-0700-000* APPLICABLE MODELS: 2014 > Mazda 3 REQUIRED COMPONENTS: ITEM QTY DESCRIPTION Usage

More information

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Safety, Installation and Service Manual Models 1952, 1953 & 1972 Ultraviolet Germicidal Lamps Model 1952 24 Rooftop Unit Model 1953 32 Rooftop Unit Model 1972 Rooftop Unit, Internal Mount Safety, Installation and Service Manual Models 1952, 1953 & 1972 READ AND SAVE

More information

Installation Instructions

Installation Instructions Installation Instructions For PTI STEZA C (2x2 Burner Configuration) & PTI STEZB C (3x1 Burner Configuration) Revision E Safe-T-Element Installation Instructions Table of Contents 1. PREPARATION..3 1.1

More information