Power Connection Kit installation instructions

Size: px
Start display at page:

Download "Power Connection Kit installation instructions"

Transcription

1 Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Power Connection Kit installation instructions Description The ET00 plug-in power connection kit is suitable for use only with the PSLL and PSL series heating cables. The kit provides material for one power connection. The PSLL and PSL series cables can be used for pipe freeze protection and/or roof and gutter de-icing. Assembly Tools Needed Utility knife, wire cutter, needle-nose pliers, adjustable wrench, pen, screwdriver, heat gun, and measuring tape. Other Material Required - Certified junction box appropriate for the site. - ET03 tape for pipe applications; ET13/ET14 roof clips and/or ET15 downspout hangers for roof and gutter de-icing. General safety information Read and understand all instructions in this manual and the following installation instructions and Safety Warnings. Electrical cables, if not installed correctly or are damaged, can present a fire, shock, and arcing hazard. 1. Installation must be in compliance with National Electrical Codes (NEC). 2. Use 30-mA ground fault protection on each heating cable branch circuit for maximum protection. Kit items 3. The black heating-cable core is conductive and can short. It must be properly insulated and kept dry. 4. The conductive layer of this heating device must have a suitable grounding/earthling terminal. 5. Installer should apply the nameplate label to surface of the junction box. 6. Keep components and ends of heating cable dry before installation. 7. Do not break braid or bus wire strands when scoring the jacket or core. Damaged bus wires can overheat or short. 8. Keep bus wires separated. Bus wires will short if they touch each other. 9. Replace damaged parts. Heatdamaged components can short. 10. Use heat gun or torch with a soft, yellow, low-heat flame, not a blue flame. Keep the flame moving to prevent overheating or blistering the heat-shrinkable tubes. item description qty. Black Shrinkable Tubing (1/8 2 B Green/Yellow Shrinkable Tubing (1/4 1 C Fitting and Black 1 D Lock 1 Black Shrinkable Tubing (1/2 1 Gasket 1 G Black 1 H Wire 3 I Labels 4 Bracket for 1 Approved 46DV pipe heating cable & 4FB1 de-icing and snow melting equipment Figure 1 Power Kit ET Do not heat other components. 12. Use only fire-resistant insulation materials such as fiberglass wrap. 13. De-energize all circuits before installation or service. 14. The heating cable should not be embedded in insulation or roofing material. 15. Do not twist cable during installation. 16. Save all instructions for future reference. Charring or burning the heat-shrinkable tubes in this kit will produce fumes that may cause eye, skin, nose, and throat irritation. C A B Figure 2 D E F G H J I

2 Power Connection Kit installation instructions Pipe Freeze Protection Heating Cable Selection(PSL series) Table 1 PSL self-regulating heating cable for METAL pipes with fiberglass insulation or equivalent (based on 40 F constant temperature with a 10% safety factor). lowest Nominal Pipe sizes Air Temp. insulation 1/2 3/4 1 1¼ 1½ 2 2½ F 1/2 3 W/ft. 3 W/ft. 3 W/ft. 3 W/ft. 5 W/ft. 5 W/ft. 5 W/ft. 5 W/ft. 5 W/ft. 8 W/ft. 8 W/ft ½ F 1/ ½ F 1/ ½ Table 2 PSL self-regulating heating cable for PLASTIC pipes with fiberglass insulation or equivalent (based on 40 F constant temperature with a 10% safety factor). lowest Air Temp. insulation 1/2 3/4 1 1¼ Nominal Pipe sizes 1½ 2 2½ F 1/2 5 W/ft. 5 W/ft. 5 W/ft. 5 W/ft. 5 W/ft. 5 W/ft. 5 W/ft. 8 W/ft. 8 W/ft. 10 W/ft.10 W/ft ½ F 1/ ½ F 1/ ½ Model Information

3 Model ET00 Pipe Freeze Protection Attaching Heating Cable to Pipe 1. Prior to installing the cable, be sure all piping is dry, and any sharp surfaces are removed. 2. The cable must be installed 10 inches away from combustible surfaces, such us wood. 3. The minimum bending radius of each flexible heating device is 1/2 inch. 4. Cut the cable to length needed. Do this before or after the cable is attached to the pipe. 5. Provide for a minimum of 1 foot extra heating cable to connect to power or for splices and tees. 6. Attach heating cable to pipe with straight, spiraling or multiple tracing. 7. If the heating cable is the same length as the pipe, run it straight along the bottom of the pipe. If two cables are required, position them in the 4 and 8 o clock positions. If three cables are required, position them in the 11 o clock or 1 o clock positions and 4 o clock and 8 o clock positions. 8. If the cable is less than double the pipe length, spiral the cable over the length of pipe. Table 3 Maximum PSL series heating Cable Circuit length 9. Any excess cable remaining at the end of the pipe can be doubled back along the pipe. 10. Be sure to include any additional heating cable required for valves, spigots, etc. 11. Secure the cable to the pipe with ET03 fiberglass application tape or nylon cable ties. DO NOT use vinyl tape, metallic products or wire. 12. Install all end seals, splices, tees and power connection prior to plugging in. 13. Protect the heating cable ends from moisture or mechanical damage if they will be left exposed before connection. Install Thermal Insulation 1. Before insulating, inspect the cable to ensure that it is free of mechanical damage, such as gouges or cuts, etc. 2. Cover the pipe, cables, connections, valves with at least 1/2 (12.7 mm) thick fiberglass insulation or equivalent. DO NOT leave the cables exposed. 3. Use fire-resistant materials such as fiberglass wrap. Make sure the insulation is waterproofed (with polyethylene or other vapor barriers) Maximum Circuit length (in Feet) Circuit Breaker for Ambient Temperature of 0 C 3PSL 20 A PSL PSL PSL PSL NOTE: Circuit breaker sizing is based on Section 427 of the National Electrical Code. Maximum circuit lengths are based on start-up load. Steady-state amps per foot depends on heating cable temperature. in areas where water may come in contact with the insulation. 4. Place the two warning labels on the outer surface of the pipe insulation where clearly visible and at suitable locations to indicate the presence of electric heating cable. Maintenace Checks 1. Only qualified persons should service or install the system. 2. Check yearly for any damage to the heating cable and check any ground fault protection device for proper operation. If any damage to cable is found, DO NOT operate until it is replaced. 3. Use a 2500 Vdc megohmmeter (500 Vdc minimum) to test the insulation resistance between the bus wire and the heater ground wire or pipe. The reading should be 20 megohms, without regard to length. Roof and Gutter de-icing heating Cable selection (PSL-CR series) 1. Calculate the total length of cable required by adding the Total roof edge length (ft.) (x feet of heating cable per foot of roof edge, see table 4), the Total gutter length (ft.), and the Total downspout length (ft.) (+1 ft.). Also add one foot for each power connection, and three feet for each tee connection. NOTE: The roof edge length (ft.) x feet of heating cable required per foot of roof edge equals the Total roof edge cable length required. 2. For Standard roofs, add 1 foot of heating cable for each foot of gutter. 3. Add 1 foot of heating cable per foot of downspout.

4 Power Connection Kit installation instructions Roof and Gutter De-icing Standard Roof Metal Roof 4. If downspout in is in the middle of the gutter run, loop the cable down and back. Double the length of the downspout for determining the length of the cable to install. 5. For roof valleys, run the heating cable two thirds of the way up and down the valley. Add this additional length to the overall cable length. 6. The circuit length for a given overcurrent protection device shall Figure 3 not exceed the maximum length specified by the manufacturer. example (standard roof): Roof Edge length ft. (with Roof overhang of 1 ft.) Gutter length ft. Downspout length ft. Power connection... 2 ea. Tee connection... 1 ea. Voltage available V Heating cable... 5PSL2-CR length of heating cable required: Roof Edge length ft. ( 2) (see table below) Gutter length ft. Downspout length (+1) ft. Power connection... 1 ft. x 2 ea. Tee connection... 3 ft. x 1 ea. Total ft. Roof Clip Hanger Bracket Installation Of De-icing Cables For Roof, Gutters And Downspouts Use only the following kits and accessories to satisfy code and agency requirements: - ET08 Plug-in Power Connection Kit - ET10 Splice and Tee Kit (if splicing or teeing) - ET12 End Seal Kit - ET15 Downspout Hangers - ET13/ET14 Roof Clips 1. Carefully plan the routing of the heating cable for roof and gutter de-icing. 2. Route the heating cable to avoid mechanical damage from ladders, etc. 3. Cut the heating cable to proper length. This can be done before or after the cable is on the pipe. Roof Clips Hanger Bracket 4. Before installing the heating cable, make sure the roof, gutter and downspouts are free from debris, leaves, pine needles or any combustibles. 5. Check the maximum exposure temperature rating of all roof, gutter and downspouts, and select a heater that will not exceed their temperature ratings. 6. The minimum installation temperature is 0 F (-18 C). 7. The heating device shall be connected to non heating leads of a weatherresistant type. The installer should protect the non heating leads from damage by installing them in a rigid metal or nonmetallic raceway. Table 4 Typical spacing and layout Measurements Feet of heating Cable per Foot of roof edge Cable loop height Roof Overhang Shingle Roof Metal Roof (24 ) Shingle Roof Metal Roof None

5 Model ET00 Roof and Gutter de-icing 8. Use hanger bracket to support the heating cable where it enters a downspout to prevent cable from being damaged by gutter edge. It also can be used as a spacer in wider gutters. 9. Run heating cable over top of hanger and secure to hanger using UV resistant cable ties. 10. Use roof clips for attaching the heating cable to the roof. 11. For roof valleys, run the heating cable two thirds of distance up and down the valley. Add the additional length to the overall cable length. 12. Protect the heating cable ends from moisture or mechanical damage before connection. 13. Field assembled end terminations should not be located in an area where moisture is present or, at the lowest point of downspouts. 14. Install end seals, splices, tees and power connection before plugging in. Follow all ET00 kit installation instructions. 15. Use only listed weatherproof junction boxes approved for wet locations when installing PSL-CR series heating cables with the ET00 Power Connection Kit. 16. Use only listed watertight construction or enclosure Type 3, 3s, 4, 4X, 6, or 6P junction box when installing. 17. Attach the two warning labels (included with the heating cable). The labels must be clearly visible on the premises. Table 5 Maximum PSL-CR series heating Cable Circuit length Maximum Circuit length (in Feet) Circuit Breaker for Ambient Temperature of 0 C 3PSL-CR 20 5PSL-CR PSL-CR The heating device shall be connected to nonheating leads of a weather-resistant type. The installer should protect the nonheating leads from damage by installing them in a rigid metal or nonmetallic raceway. Maintenance Checks 1. Only qualified persons should service or install the system. 2. Check yearly for any damage to the heating cable and check any ground fault protection device for proper operation. If any damage to cable is found, DO NOT operate until it is replaced. 3. With a 2500 Vdc megohmmeter (500 Vdc minimum) test the insulation resistance between the bus wire and the heater grounding braid or metal pipe. The reading should be 20 megohms at any length of cable. NOTe: Circuit breaker sizing is based on Section 427 of the National Electrical Code. Maximum circuit lengths are based on start-up load. Steady-state amps per foot depends on heating cable temperature. Table 6 Product data for PSL-CR series heating Cables for roof and Gutter de-icing Model service Voltage Thermal F (in ice & snow) Min. installation Temp. Max. exposure Temp. Chemical exposure Environmental Restrictions 3PSL1-CR 120V 6 Watts/ft. 0 F 185 F Aqueous inorganic Nonhazardous & hazardous 3PSL2-CR Aqueous inorganic Nonhazardous & hazardous 5PSL1-CR Aqueous inorganic Nonhazardous & hazardous 5PSL2-CR Aqueous inorganic Nonhazardous & hazardous 8PSL1-CR Aqueous inorganic Nonhazardous & hazardous 8PSL2-CR Aqueous inorganic Nonhazardous & hazardous

6 Power Connection Kit installation instructions Power Connection Kit installation instructions 5. Place braid onto one side of heating cable. Cut inner jacket of cable back 6 (152mm). Figure 9 Figure 4 NOTe: Instructions generally show heating cable with braid and outer jacket. Cables with no outer jacket look slightly different from those illustrated. 6. Shave off outer matrix material from conductors with utility knife. See Figure Open the sealing fitting and slide the junction box fitting cap, strain relief disk, grommet, and fitting body onto the power connection end of cable. 3. Gently push braid back to loosen and spread apart braid as shown. Figure 5 2. Score completely around heating cable outer jacket, and then score down a distance of 7 (178mm), being careful not to cut braid or inner jacket. Then, bend heating cable to break jacket at score, and peel off outer jacket. Figure 7 4. Bend heating cable enough to work it through the braid opening. Figure Peel back exposed wires from central matrix material. See Figure 11. do not cut bus wire strands! Figure 8 Figure 11 Figure 6

7 Model ET00 Power Connection Kit installation instructions 8. Cut off remaining center core of matrix; leaving the bare conductors. do not cut bus wires! 11. Then, insert green/yellow tube over braid and shrink. 14. While tube is still hot, pinch tube with pliers, between wires, and hold for 10 seconds to ensure seal. See Figures 18 & 19. Figure Slip on black shrink tubes 5½ (140mm) in place up to conductive core. Figure Center black shrink tube 1 (25mm) over end of heating cable as shown in Figure 16. Figure 18 Figure Carefully shrink tubing by moving heat source from side to side continuously; being careful not to damage heating cable. Figure Heat tube evenly until it shrinks and adhesive flows out both ends. Figure For heating cables with an outer jacket, slide parts in place as shown below. Figure 14 Figure 17 Figure 20

8 Power Connection Kit installation instructions Power Connection Kit installation instructions 16. Slide parts in place. For heating cables without an outer jacket, see Figure 21; with outer jacket, see Figure Use a metallic junction box to ensure a proper ground. Insert heating cable and tighten. NOTE: For PSL2-CR heating cables When used in wet locations, follow instructions provided with junction box to seal out water. NOTE: Allow at least 6 of lead wire inside an outlet box. Figure 25 For heating cables with outer jacket, see Figure 26. Figure 21 Figure Loosely attach the metal pipe mounting bracket to the pipe with the metal band. Position the bracket so that the cable and fitting come straight up and through the hole. Then tighten the band. Figure Make connections as shown in Figures 25 & 26. Connect the power conductors to the cable leads. Connect the incoming supply ground to the cable braid and to the green ground wire. The wire nuts, included, are not for use with aluminum feed wires. The junction box needs to be grounded. For heating cables without outer jacket, see Figure 25. Figure For roof and gutter applications, put warning label on junction box. See Figure 27. Figure 23 Limited Warranty Figure 27 All products sold are warranted by Drexma only to customers for resale, or for use in business, or original equipment manufacture, against defects in workmanship or materials under normal use for one year after date of purchase from Drexma.

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife

More information

ET-PWR-END-KIT Installation Instructions (part #JSR00)

ET-PWR-END-KIT Installation Instructions (part #JSR00) (part #JSR00) Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety

More information

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series) PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire

More information

H900 WinterGard Power Connection Kit with End Seal Installation Instructions

H900 WinterGard Power Connection Kit with End Seal Installation Instructions H900 WinterGard Power Connection Kit with End Seal Installation Instructions Power connection for H311, H611, and H621 Power connection for H612 and H622 Description The WinterGard power connection kit

More information

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating

More information

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions SRK02 Hard Wire Power Connection Kit Installation, Operation and Maintenance Instructions IMPORTANT: Save These Instructions! Item Qty Description A 1 Black heat shrink tube (1/2 dia. x 1 length) B 2 Black

More information

C A Heating Cable Gland Kit Installation Instructions

C A Heating Cable Gland Kit Installation Instructions C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions JBM-100-STB NEMA 4X-rated connection kit Installation Instructions Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box Approvals Hazardous Locations CLI,

More information

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner

More information

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1). R AMG-BC-III AutoMatrix Power Connection Kit Description The AMG-BC-III is a copper free aluminum (maximum 4/10 of 1% copper) NEMA 4X (1) rated power connection kit for single or dual heating cable entry.

More information

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions SPC-P with Pyrotenax MI heating cable using required MI cable grounding kit SPC-P with Raychem

More information

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt. Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &

More information

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions Description The JBS-100-STB is a NEMA 4X rated power connection kit. It is designed for use with Raychem BTV-CR, BTV-CT,

More information

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS DESCRIPTION The PolyMatrix PMKG-JS is a NEMA 4X rated splice connection kit for use with Raychem BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT

More information

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions Description The PolyMatrix PMKG-J2LP is a NEMA 4X rated connection kit for use with Raychem BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT and

More information

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS DESCRIPTION The JBS-100-A and JBS-100-A6 are NEMA 4X-rated power connection kit. It is designed for use with Raychem

More information

HTP PTP/ PTJ Power Connection Kit for Pipes

HTP PTP/ PTJ Power Connection Kit for Pipes HTP 1548-40PTP/1548-40PTJ Power Connection Kit for Pipes For use with Dekoron 2700 and 2300 Families of Heating Cables. 1548-81HTJ/81HTP for use with 2000 Series Heating Cables. Installation Instructions

More information

120/240 Volts 3 Watt Floor Heating Cable System

120/240 Volts 3 Watt Floor Heating Cable System WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable

More information

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system Installation guide Ecoflex potable PEX plus pre-insulated pipe system installation guide l 1 Uponor Ecoflex potable PEX plus pre-insulated pipe system

More information

Power-Limiting Cables

Power-Limiting Cables Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your

More information

Kompensator External Low Voltage Heating Cable System

Kompensator External Low Voltage Heating Cable System External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................

More information

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.

More information

HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES

HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES HWAT System INSTALLATION AND OPERATION MANUAL FOR HOT WATER TEMPERATURE MAINTENANCE SYSTEMS FOR THERMALLY INSULATED PIPES THERMAL MANAGEMENT SOLUTIONS WWW.THERMAL.PENTAIR.COM Important Safeguards and Warnings

More information

3M Self Regulating Heating Cables

3M Self Regulating Heating Cables 2 Construction & Function 3M Self Regulating Heating Cables Introduction: 3M Canada and Thermon Manufacturing Company have entered into a strategic alliance to market the commercial line of heat tracing

More information

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet

More information

TSRT TSRT Tee Splice Kit Installation Instructions

TSRT TSRT Tee Splice Kit Installation Instructions TSRT TSRT Tee Splice Kit Installation Instructions Description The TSRS Splice Connection Kit is for use with all versions of EasyHeat s self regulating heater cables smaller than 0.44 (11mm) in diameter.

More information

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE For commercial and industrial applications Heating cable construction Insulation (magnesium oxide) Heating conductor Copper sheath HDPE

More information

Product Overview. Application

Product Overview. Application Self-Regulating SC, SC/H Series-resistance heating cables for longline systems Electrical freeze protection for long pipelines in both nonhazardous and hazardous locations Power-Limiting Mineral Insulated

More information

Introduction to Heat Trace Cable Systems

Introduction to Heat Trace Cable Systems Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).

More information

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables Power Connection Kit Installation Instructions Terminator DP-M for use with TEK and HTEK series constant watt heating cables For Power Connection (1 Cable), In-Line Splice Connection, or End Termination

More information

QUICKTERM TERMINATION KIT

QUICKTERM TERMINATION KIT PYROTENAX QUICKTERM TERMINATION KIT INSTALLATION INSTRUCTIONS FOR TERMINATING SINGLE CONDUCTOR COPPER SHEATHED MINERAL INSULATED CABLE DESCRIPTION This termination kit is used to terminate #6 AWG and larger

More information

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) TRACING S CONTENTS page Constant Watt Cable Self-Regulating Cable SECTION 1. OVERVIEW 1.1 Precautions... 2 1.2 Cable and components...

More information

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the

More information

HAK-C-100 CONNECTION KIT FOR DIVISION 1 HAZARDOUS LOCATIONS INSTALLATION INSTRUCTIONS

HAK-C-100 CONNECTION KIT FOR DIVISION 1 HAZARDOUS LOCATIONS INSTALLATION INSTRUCTIONS HAK-C-100 CONNCTION KIT FO DIVISION 1 HAZADOUS LOCATIONS INSTALLATION INSTUCTIONS APPOVALS Hazardous Locations (1) (1) xcept VPL. KIT CONTNTS Class I, Div. 1, Groups B, C, D Class II, Div. 1, Groups, F,

More information

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables Power Connection Kit Installation Instructions Terminator ZP-M for use with TEK and HTEK series constant watt heating cables For Power Connection (1 Cable), In-Line Splice Connection, or End Termination

More information

HAK-C-100 CONNECTION KIT FOR DIVISION 1 HAZARDOUS LOCATIONS INSTALLATION INSTRUCTIONS

HAK-C-100 CONNECTION KIT FOR DIVISION 1 HAZARDOUS LOCATIONS INSTALLATION INSTRUCTIONS HAK-C-100 CONNCTION KIT FO DIVISION 1 HAZADOUS LOCATIONS INSTALLATION INSTUCTIONS APPOVALS Hazardous Locations (1) (1) xcept VPL. KIT CONTNTS Class I, Div. 1, Groups B, C, D Class II, Div. 1, Groups, F,

More information

Installation Instructions

Installation Instructions K-Series Constant-Wattage Heating Cable Installation Instructions Read and understand this material before installing this heater. Failure to understand how to safely install the heater could result in

More information

SELF-REGULATING CABLES

SELF-REGULATING CABLES Self-Regulating SELF-REGULATING CABLES This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Self-regulating cables

Self-regulating cables Self-Regulating Self-regulating cables This step-by-step design guide provides the tools necessary to design a selfregulating heat-tracing system for insulated pipes and tubing. For other applications

More information

Self-Regulating Cables

Self-Regulating Cables Self-Regulating 1. Self- Regulating 2. Power- Limiting This step-by-step design guide provides the tools necessary to design a self-regulating heat-tracing system for insulated pipes and tubing. For other

More information

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables... Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss

More information

Heating Cable. Cut to Length in Field. Description

Heating Cable. Cut to Length in Field. Description Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection

More information

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive

More information

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,

More information

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace pipe freeze protection or flow maintenance system. For

More information

Electric Heat Tracing INSTALLATION PROCEDURES

Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing INSTALLATION PROCEDURES Electric Heat Tracing Complete Electric Heat Tracing System... Illustration A: Typical Heat Tracing Installation A complete electric heat tracing system will

More information

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999 STOCKPORT, ENGLAND, TEL: 0161-430 8333 POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS PLEASE READ THE INSTRUCTIONS BEFORE PROCEEDING Recommended Tools ANNEX B Ref TK/AHT Issue C Date 16 August 1999 Heavy

More information

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal building solutions WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

MASTERsine Inverter PXA Series Installation Guide

MASTERsine Inverter PXA Series Installation Guide Backup Power System Expert TM MASTERsine Inverter PXA Series Installation Guide Important Safety Instructions IMPORTANT: Read and save this Installation Guide for future reference. This chapter contains

More information

VITALink Taped Splice Pigtail Crimp

VITALink Taped Splice Pigtail Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice

More information

WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES

WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES WarmTrace TM HSX Safety Comes First... The safety and performance of a heat tracing system depends on how the system was designed,

More information

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket SELF-REGULATING HEATING CABLE For pipe freeze protection and flow maintenance Heating cable construction Tinned-copper braid Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket Modified polyolefin

More information

WRSS Wraparound Repair Sleeve Installation Instructions

WRSS Wraparound Repair Sleeve Installation Instructions WRSS Wraparound Repair Sleeve Installation Instructions TECP-30-263. Issue 1. 4/2016 1.0 General Product Information This practice provides information regarding the description and use of Raychem s WRSS

More information

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information

More information

THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller

THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller Revision 3 THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express

More information

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Terminator DP/HT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Terminator DP/HT The following installation procedures are suggested guidelines for the installation

More information

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables Lighted Power Connection / Lighted End Termination Kit Installation Instructions Terminator DL-L for use with RSX, TSX, VSX self-regulating heating cables Terminator DL-S for use with BSX *, HTSX, KSX

More information

Pipe Freeze Protection Design/Install Guide

Pipe Freeze Protection Design/Install Guide Pipe Freeze Protection Design/Install Guide Page 1 of 16 Pipe Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 STEP 1 Information Required Page 4 STEP 2 Design Considerations Page

More information

TubeTrace Tubing Bundles

TubeTrace Tubing Bundles for Custom CEMS and Analytical Umbilicals English Units Receiving, Storing and Handling... 1. Inspect materials for damage incurred during shipping. Report damages to carrier for settlement. 2. Identify

More information

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks Instructions June 2002 78-8130-2161-1-B 1 Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Cable Preparation...

More information

WOC & WOC Top & Back Installation Instructions

WOC & WOC Top & Back Installation Instructions Shown with optional Sun Roof WOC-900500-2 & WOC-900501-2 Top & Back Installation Instructions Install Order! Heater Door System Wiper on to Windshield Windshield Rear Panel Top Panel Tools needed: 5/16

More information

Terminator DP/FAK-5 and FAK-5L

Terminator DP/FAK-5 and FAK-5L for T-Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of the Terminator DP/FAK-5 and FAK-5L:

More information

Heating Cables. For Industry Tracing

Heating Cables. For Industry Tracing Heating Cables For Industry Tracing FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length

More information

DEF-Trac. Design and Installation Guide. August 2015

DEF-Trac. Design and Installation Guide. August 2015 DEF-Trac Design and Installation Guide August 205 DEF-Trac Featuring a Flexible Corrugated Stainless Steel Core 2 TABLE OF CONTENTS Section Page No..0 User Warnings... 4. DEF-Trac Flexible Piping System...

More information

Self-Regulating Freeze Protection Heating Cable

Self-Regulating Freeze Protection Heating Cable D PDS SRF Self-Regulating Freeze Protection Heating Cable E C B A Output Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Freeze Protection of

More information

Connection kits for joining all types of DEVI self-limiting heating cables to cold tails

Connection kits for joining all types of DEVI self-limiting heating cables to cold tails Intelligent Heating Connection kits for joining all types of DEVI self-limiting heating cables to cold tails Fitting set (art. no. 19805761) Cold tail fitting set: 1 crimp tube type 12/3, L =20 mm 2 crimp

More information

In-Line / T-Splice Kit Installation Instructions. Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables

In-Line / T-Splice Kit Installation Instructions. Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables In-Line / T-Splice Kit Installation Instructions Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables Terminator DS-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting,

More information

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930 PRODUCT CODES NAMSR-Wattage-Voltage-Length // eg: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly

More information

Termination Procedure for 723 Series SolderTacts Contacts for Coaxial Cable: D , D

Termination Procedure for 723 Series SolderTacts Contacts for Coaxial Cable: D , D enlo Park, CA 94025 USA Print 12-Jun-03 1 of 11 Termination Procedure for 723 Series SolderTacts Contacts for Coaxial Cable: D-602-44, D-602-45 1. Scope This engineering standard contains the termination

More information

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate Fullsize Ford Van- 1992-present Preparing the Gate 1. Remove the mounting hardware which is banded to the liftgate. 2. Verify mounting kit (Figure 1 and Table 1). S-400-40 STRAP VAN MOUNTING EAR BENT BRACKET

More information

Installation Instructions Mineral Insulated (M.I.)

Installation Instructions Mineral Insulated (M.I.) Installation Instructions Mineral Insulated (M.I.) trace ASSEMBLY Contents page Section 1. Overview 1.1 Precautions... 2 1.2 M.I. cable and components... 2 1.3 General accessories... 3 1.4 Tools required...

More information

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS MIQ INSTALLATION INSTRUCTIONS MIQ CATALOGUE REF. NO. Example: D / MIQ-50E3H-2S / 200 / 1404 / 120 / 4 / 12 / 6 Design (A,B,D,E) Cable Reference Length (Feet or Meters) Watts Volts Cold Lead Length (Feet

More information

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES Terminator DP/FAK-5LHT The following installation procedures are suggested guidelines for the

More information

Installation & Operation Instructions. Type USL Signal Light Kit for Self-Regulating Constant Wattage Heating Cables. Constant Wattage Grommet

Installation & Operation Instructions. Type USL Signal Light Kit for Self-Regulating Constant Wattage Heating Cables. Constant Wattage Grommet Chromalox Installation & Operation Instructions DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE SECTION RT (Supersedes PF477-1) PJ937 161-562581-032 DECEMBER, 2007 Type USL Kit for Self-Regulating Constant

More information

DEF-Trac. Design and Installation Guide. August 2014

DEF-Trac. Design and Installation Guide. August 2014 DEF-Trac Design and Installation Guide August 204 A DEF-Trac Featuring a Flexible Corrugated Stainless Steel Core 2 TABLE OF CONTENTS USER WARNINGS... 4 DESIGN SPECIFICATIONS... 4 INSPECTION / HANDLING

More information

Terminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of the Terminator DP/FAK-4 and FAK-4L

More information

PETK Power and End Termination Kit

PETK Power and End Termination Kit PETK Power and End Termination Kit INSTALLATION PROCEDURES Made in USA PETK-1 for BSX, RSX, VSX PETK- for KSX, HTSX PETK- for HPT, FP PETK--ECM for HPT, FP Order separately to be used in conjunction with

More information

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930 PRODUCT CODES NAMSR-Wattage-Voltage-Length. Ex: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly

More information

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR DESCRIPTION The Snow Switch Model SIT 6E Pavement-Mounted Snow and Ice Sensor reliably detects snow and ice conditions on pavement surfaces when used

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing H-Tap Insulating Covers (Hard Covers) Interlocking insulating covers for H-type compression taps Easy installation: place the H-Tap in the cover and snap the cover closed Consult your Regional Sales Office

More information

Chapter 8 Interior Wiring and Lighting

Chapter 8 Interior Wiring and Lighting Chapter 8 Interior Wiring and Lighting Review Questions 1. What tool if any, is used to remove a fuse that is to be replaced? 1. Pliers 2. Screwdriver 3. Fuse puller 4. None 2. OSHA has established specific

More information

RTB Tubing Bundles Installation Guide. Heating solutions for instrument and small-diameter process lines

RTB Tubing Bundles Installation Guide. Heating solutions for instrument and small-diameter process lines RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines WARNING: Fire and shock hazard. Raychem heat-tracing systems must be installed correctly to ensure

More information

Safe-T-element Installation Instructions

Safe-T-element Installation Instructions Safe-T-element Installation Instructions For: PTI STEZA (2x2 Burner Configuration) & PTI STEZB (3x1 Burner Configuration) Revision K (May. 3 2012) TABLE OF CONTENTS 1. PREPARATION... 3 1.1 General Safety

More information

FREEZSTOP MICRO SYSTEM

FREEZSTOP MICRO SYSTEM FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 25mm diameter water pipe at +5

More information

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.anderson-negele.com Instrument Model Number Instrument Serial Number Model

More information

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...

More information

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA eltherm Canada Inc. 1440 Graham s Lane, Unit 5 Burlington Ontario L7S 1W3 Canada Phone: +1 (289) 812-6631 Fax: +1 (844) 325-6750 E-Mail:

More information

PETK Power and End Termination Kit

PETK Power and End Termination Kit Power and End Termination Kit PETK-1D PETK-2D PETK-D for BSX, RSX, VSX for KSX, HTSX for HPT, FP Order separately to be used in conjunction with Thermon connection kits Receiving, Storing and Handling...

More information

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation

More information

ThermoLite 110W-330W Solar Panel Installation Instructions

ThermoLite 110W-330W Solar Panel Installation Instructions ThermoLite 110W-330W Solar Panel Installation Instructions INSTALL APPLICATIONS SUPPORTED BY THIS GUIDE: 1. Trailer Roof Top Mounted 2. Bus Roof Top Mounted 3. Tractor Fairing Mounted 40W and 110W Replacement

More information

INSTRUCTIONS. for ZONE HEATERS STACKPAK

INSTRUCTIONS. for ZONE HEATERS STACKPAK Contents Page Model Number and Identification 2-3 Receiving and Storage 4 Installation Minimum Installation Temperature 4 Planning Installation and Determining Length with Zone Heaters 4-5 Uncoiling and

More information

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series) LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY

More information

Lakela nd H2 Low Speed Stator Coil Installation

Lakela nd H2 Low Speed Stator Coil Installation Lakela nd H2 Low Speed Stator Coil Installation Step 1: Place the stator assembly on a padded surface to protect the plastic signal generators, and orient it as shown in figure 1. The low speed coil is

More information

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS CommScope MULTILAYERED 289-TYPE 63-460-32-03 BUILDING ENTRANCE PROTECTOR (BEP) Issue 5, February 2004 Material ID 847 364 882 INSTALLATION INSTRUCTIONS General This instruction sheet provides procedures

More information

Busway Construction. Bus Bars

Busway Construction. Bus Bars Busway Construction Bus Bars A better understanding of what busway is can be gained by examining its construction. A typical Siemens Sentron busway section has three or four formed aluminum or copper bars

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 40454 XM SATELLITE RADIO 2009 S2000 Issue Date AUG 2008 PARTS LIST Template XM Radio Unit Kit (sold separately): P/N 08A53-S2A-101 XM

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. 2004 S2000 AII 26323-31611 Issue Date DEC 2005 PARTS LIST Rear defroster switch Hardtop 3-Pin subharness (If equipped, not used) 4-Pin subharness

More information