1 Technical Catalogue Switch Disconnectors Sizes 25 to 200A, 250 to 1000A, 1250 to 3150A Switch Fuses Sizes 32A, 63A, 125A, 200A, 315A, 400A, 630A, 800A Australian Distributor: Bridex Australia Pty Ltd Telephone: Fax:
2 Website: Contents Switch Disconnectors (Sizes 25A, 40A, 63A, 125 & 200A)...3 Switch Disconnectors (Sizes 250A, 400A, 630A, 800A & 1000A)...4 Switch Disconnectors (Sizes 1250A, 1600A, 1800A, 2500A & 3500A)...5 Switch Disconnectors Drawing Diagrams Switch Disconnectors Drawing Diagrams Switch Disconnector Accessories...8 Switch Fuses Sizes 32A and 63A...10 Switch Fuses Sizes 125A and 200A...12 Switch Fuses Sizes 315A and 400A...14 Switch Fuses Sizes 630A and 800A...16 Switch Fuses Drawing Diagrams Switch Fuses Drawing Diagrams Switch Fuse Accessories
3 Switch Disconnectors (Sizes 25A, 40A, 63A, 125 & 200A) ASTA Certified to IEC Tested by TCA Lane Cove, Sydney Switch Sizes Sizes 25, 40 and 63 Size 125 Size 200 Switch Size Pole Catalog No. CSSD25D1 CSSD40D1 CSSD63K3 CSSD125D1 CSSD200D1 4-Pole Catalog No. CSSD25D4 CSSD40D4 CSSD63D4 CSSD125D4 CSSD200D4 Rated Insulation Voltage 660V 660V 660V 660V 1000V Rated Operational Voltage 660V 660V 660V 660V 660V Rated Thermal Current (AC21 at 660V AC) Open 40 C Ambient 25A 40A 63A 125A 250A Encl 40 C Ambient 25A 40A 63A 125A 200A Encl 60 C Ambient 25A 32A 50A 100A 175A (D21 at 220V Open 40 C Ambient 25A 40A 63A - 200A Rated Operational Current AC22/AC23 at 415V 25/25A 40/25A 63/63A 125/75A 250/200A AC22/AC23 at 660V 25/16A 40/25A 63/30A 80/35A 250/200A DC22/DC23 at 220V 25/-A 40/-A 40/-A 50/50A 200/200A Rated Operational Power AC23 at 415V 7.5kW 11kW 25kW 37kW 100kW Fused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating 40A 50A 80A 125A 200A Maximum Peak Let Through (protected with back up fuses) 4.5kA 5kA 8kA 10kA 40kA Short Circuit Making (peak) 1.53kA 1.7kA 2.55kA 4.25kA 40kA Short Time Withstand 0.1 second 1.3kA 1.4kA 1.9kA 2.5kA 30kA 1.0 second 0.9kA 1.0kA 1.5kA 2.5kA 24kA AC Breaking Capacity p.f. 0.35/415V 250A 320A 500A 600A 1600A DC Breaking Capacity 220V (3p in series L/R=15mS) 160A* 160A* 160A* 200A* 1260A**,*** Capacitor Rating 415V KVAr 90KVAr Rated Capacitor Duty Ic A 135A Mechanical/Electrical Endurance (at rated operational Current p.f.0.65) 40k/5k 40k/5k 40k/5k 40k/5k 10k/1k Weight Notes: 3-Pole 0.2kg 0.2kg 0.3kg 0.3kg 4.5kg 4-Pole 0.25kg 0.25kg 0.4kg 0.4kg 5.4kg * L/R = 2.5mS ** With one pole when tested at 48/110V DC *** Two poles in series. 3
4 Switch Disconnectors (Sizes 250A, 400A, 630A, 800A & 1000A) ASTA Certified to IEC Tested by TCA Lane Cove, Sydney Switch Sizes Sizes 250 and 400 Size 630 and 800 Size 1000 Switch Size Pole Catalog No. CSSD250D1 CSSD400D1 CSSD630K3 CSSD800K3 CSSD1000K3 4-Pole Catalog No. CSSD250D4 CSSD400D4 CSSD630K4 CSSD800K4 CSSD1000K4 Rated Insulation Voltage 1000V 1000V 1000V 1000V 1000V Rated Operational Voltage 660V 660V 660V 660V 660V Rated Thermal Current (AC21 at 660V AC) Open 40 C Ambient 315A 500A 630A 800A 1000A Encl 40 C Ambient 250A 400A 630A 720A 1000A Encl 60 C Ambient 220A 350A 500A 600A 900A (D21 at 220V Open 40 C Ambient 250A 400A 630A 800A 1000A Rated Operational Current AC22/AC23 at 415V 315/250A 500/400A 630/630A 800/700A 1000/800A AC22/AC23 at 660V 315/250A 500/400A 630/420A 800/420A - DC22/DC23 at 220V 250/250A 400/400A 400/630A** 500/630A** - Rated Operational Power AC23 at 415V 130kW 200kW 315kW 350kW 400kW Fused Short Circuit Current 100kA 100kA 80kA 80kA 50kA With Back Up Fuse Rating 250A 400A 630A 800A 800A Maximum Peak Let Through (protected with back up fuses) 40kA 40kA Short Circuit Making (peak) 40kA 40kA 50kA**** 50kA**** 105kA Short Time Withstand 0.1 second 30kA 35kA 35kA 40kA 60kA 1.0 second 24kA 24kA 24kA 24kA 50kA AC Breaking Capacity p.f. 0.35/415V 2000A 3200A 5040A 5760A 6400A DC Breaking Capacity 220V (3p in series L/R=15mS) 1260A** 1600A** 1600A** 2000A** 1900A** Capacitor Rating 415V 110KVAr 250KVAr 300KVAr 350KVAr 630KVAr Rated Capacitor Duty Ic 170A 400A 450A 500A 900A Mechanical/Electrical Endurance (at rated operational Current p.f.0.65) 10k/1k 10/1k 10k/0.5k 10k/0.5k 10k/0.5k Weight Notes: 3-Pole 4.5kg 4.5kg 5.2kg 5.4kg 11.5kg 4-Pole 5.4kg 5.4kg 6.1kg 6.5kg 15kg ** Two Poles in Series **** Distance between terminal bolts and insulator of the busbar, 2 x pole distance. 4
5 Switch Disconnectors (Sizes 1250A, 1600A, 1800A, 2500A & 3500A) ASTA Certified to IEC Tested by TCA Lane Cove, Sydney Switch Sizes Size 1250 Sizes 1600 and 1800 Sizes 2500 and 3150 Switch Size Pole Catalog No. CSSD1250K3 CSSD1600K3 CSSD1800K3 CSSD2500K3 CSSD3150K3 4-Pole Catalog No. CSSD1250K4 CSSD1600K4 CSSD1800K4 CSSD2500K4 CSSD3150K4 Rated Insulation Voltage 1000V 1000V 1000V 1000V 1000V Rated Operational Voltage 660V 660V 660V 660V 660V Rated Thermal Current (AC21 at 660V AC) Open 40 C Ambient 1250A 1600A 1800A 2500A 3150A Encl 40 C Ambient 1250A 1600A 1600A 2300A 2700A Encl 60 C Ambient 1000A 1250A 1250A - - (D21 at 220V Open 40 C Ambient 1250A 1600A 1600A 1600A 1600A Rated Operational Current AC22/AC23 at 415V 1250/800A 1600/800A 1600/800A 1600/-A 1000/-A AC22/AC23 at 660V - DC22/DC23 at 220V - Rated Operational Power AC23 at 415V 400kW 400kW 400kW 400kW 400kW Fused Short Circuit Current 50kA 50kA* 50kA* 50kA* 50kA* With Back Up Fuse Rating 1000A 1250A 1250A 1250A 1250A Maximum Peak Let Through (protected with back up fuses) Short Circuit Making (peak) 105kA 105kA 105kA 105kA 105kA Short Time Withstand 0.1 second 60kA 60kA 60kA 110kA 110kA 1.0 second 50kA 50kA 50kA 80kA 80kA AC Breaking Capacity p.f. 0.35/415V 6400A 6400A 6400A 6400A 6400A DC Breaking Capacity 220V (3p in series L/R=15mS) 1900A** 2600A** 2600A** 2600A** 2600A** Capacitor Rating 415V Rated Capacitor Duty Ic Mechanical/Electrical Endurance (at rated operational Current p.f.0.65) 10k/0.5k 10k/0.5k 10k/0.5k 6k/0.5k 6k/0.5k Weight 3-Pole 11.5kg 15.6kg 15.6kg 36.2kg 36.2kg 4-Pole 15.0kg 20.0kg 20.0kg 45.4kg 45.4kg Notes: * With back up circuit breaker time delayed 0.5 second maximum ** Two poles in series 5
6 Switch Disconnectors Drawing Diagrams 1 Switch Disconnectors: Dimensions (mm) CSSD25,40 D1/D4 CSSD25, 40 D1/C1 CSSD25, 40 D4/C4 CSSD25, 40 C1/C4 Handle CSSDZX104 CSSD63K3 CSSD63K3/C3 CSSD63C3 Handle CSSDZX104 CSSD125D1 CSSD63D3, 125D4 CSSD125D1/C1 CSSD63D4, 125D4/C4 CSSD125C1/C4 Handle CSSDZX104 6
7 Switch Disconnectors Drawing Diagrams 2 Switch Disconnectors Dimensions (mm) TYPE a b c d e f g h CSSD200D CSSD200D CSSD250D CSSD250D CSSD400D CSSD400D CSSD630K CSSD630K CSSD800K CSSD800K Handle: YASDB16 Shaft : CSSFZK9 L = 255mm TYPE a b c d CSSD1000K CSSD1000K CSSD1250K CSSD1250K CSSD1600K CSSD1600K CSSD1800K CSSD1800K Handle: YASDB16 Shaft : CSSFZK9 L = 255mm TYPE a b CSSD2500K CSSD2500K CSSD3150K CSSD3150K Handle: YASDA8 Shaft : CSSFZK41 L = 325mm 7
8 Switch Disconnector Accessories EXTENDED SHAFTS Shaft Dimension Switch Size Length (mm) Catalog No. 5 mm square CSSD CSSDZS37 12 mm square CSSD CSSDFZK41 12 mm square CSSD CSSDFZK44 AUXILLIARY CONTACTS Switch Size No. Poles Catalog No. CSSD25 D1 3-pole CSSDZX49 CSSD40 D1 3-pole CSSDZX49 CSSD63 D4 4-pole CSSDZX87 CSSD63 K3 3-pole CSSDZX79 CSSD125 D1 3-pole CSSDZX52 CSSD25 D1 3-pole CSSDZX50 CSSD40 D1 3-pole CSSDZX50 CSSD63 D4 4-pole CSSDZX88 CSSD63 K3 3-pole CSSDZX80 CSSD125 D1 3-pole CSSDZX53 CSSD200 to CSSD400 3-pole CSSDZX34 CSSD630 to CSSD pole CSSDZX35 CSSD630 to CSSD pole CSSDZX36 Terminal Shrouds CSSD125 D1 3-pole CSSDZX9 CSSD200 D1 3-pole CSSDZX11 CSSD250 D1 3-pole CSSDZX31 CSSD400 D1 3-pole CSSDZX31 CSSD630 K3 3-pole CSSDZX93 CSSD800 K3 3-pole CSSDZX112 CSSD1000 K3 3-pole CSSDZX102 CSSD1250 K3 3-pole CSSDZX102 CSSD125 D4 4-pole CSSDZX59 CSSD200 D4 4-pole CSSDZX64 CSSD250 D4 4-pole CSSDZX32 CSSD400 D4 4-pole CSSDZX32 CSSD630 K4 4-pole CSSDZX94 CSSD800 K4 4-pole CSSDZX112 CSSD1000 K4 4-pole CSSDZX102 CSSD1250 K4 4-pole CSSDZX102 8
9 Changeover Mechanisms CSSD25 to CSSD125 CSSDZW6 CSSD200 to CSSD800 CSSDZW11 CSSD1000 to CSSD3150 CSSDZW12 Locking Attachment CSSD25 to CSSD125 CSSDZW16 CSSD200 to CSSD3150 CSSDZW5 Handles ON OFF CSSD25 to CSSD125 CSSDZX104 ON OFF CSSD200 to CSSD800 YASDB16 ON OFF CSSD1000 to CSSD3150 YASDA8 ON - OFF - ON CSSD25 to CSSD125 YASDB37 ON - OFF - ON CSSD200 to CSSD3150 YASDA6 9
10 Switch Fuses Sizes 32A and 63A Catalogue Nos: CSSF32GI and CSSF63GI ASTA Certified to IEC Tested by TCA Lane Cove, Sydney Switch Sizes Sizes 32 and 63 BS Pattern Catalog No. CSSF32GI CSSF63GI Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 32A 63A current AC22 Ambient temp. 40 C In enclosure (no ventilation) 660V 32A 63A free mounting position. note (1) In enclosure (solid links) 660V 40A 75A Rated Operational voltage 500V 660V Rated operational current in categories 220V 32A 63A AC23 and AC3. Time interval between 380V 32A 63A 20 seconds in AC3. 415V 32A 63A 660V - 40A Rated operational current DC23 Two poles in series 110V - 63A Two poles in series 220V - 63A Three poles in series 440V - 30A Rated operational power in categories 220V 7.5kW 15kW AC23 and AC3. Time interval 380V 11kW 30kW between 415V 15kW 30kW 20 seconds in AC3 note (2) 500V 15kW 30kW 660V - 30kW Rated breaking capacity 500V 300A 500A AC23.COSø = V - 350A Rated breaking capacity 110V - 300A DC, L/R = 15mS 220V - 250A 440V - - Rated fused short circuit current R.M.S. Value 500V 50kA 50kA and making capacity on Peak Value 500V 105kA 105kA fault level... R.M.S. Value 660V 50kA 50kA Peak Value 660V 105kA 105kA...with back up fuses of rating 35A 63A Maximum peak let through current 660V 6kA 10KA (4) Rated short-time withstand current 1sec 660V 15kA 2kA Rated capacitor power note (3) 380V 15kVAr 30kVAr 415V 16kVAr 32kVAr 10
11 Mechanical / Electrical endurance 3-pole switch fuses 20000/ /1500 at rated current PF 0.65 Fuse types BS pattern BS88 A2-A3 A2-A3 distance of fixing holes 73mm 73mm Weight 3-pole switch fuses 1.6kg 1.6kg Notes: (1) Ambient temperature 60 C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link. (4) UC-415V at 660V max peak let through is 8kA. 11
12 Switch Fuses Sizes 125A and 200A Catalogue Nos: CSSF100GI and CSSF200B3 ASTA Certified to IEC Tested by TCA Lane Cove, Sydney Switch Sizes Size 125 Size 200 BS Pattern Catalog No. CSSF100GI CSSF200B3 Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 125A 200A current AC22 Ambient temp. 40 C In enclosure (no ventilation) 660V 115A 200A free mounting position. note (1) In enclosure (solid links) 660V 125A 280A Rated Operational voltage 660V 660V Rated operational current in categories 220V 115A 200A AC23 and AC3. Time interval between 380V 115A 200A 20 seconds in AC3. 415V 115A 200A 660V 115A 200A Rated operational current DC23 Two poles in series 110V 63A 200A Two poles in series 220V 125A 200A Three poles in series 440V 100A 200A Rated operational power in categories 220V 37kW 57kW AC23 and AC3. Time interval 380V 55kW 100kW between 415V 60kW 110kW 20 seconds in AC3 note (2) 500V 75kW 140kW 660V 55kW 180kW Rated breaking capacity 500V 800A 3200A AC23.COSø = V 500A 3200A Rated breaking capacity 110V 500A 1600A DC, L/R = 15mS 220V 400A 1200A 440V A Rated fused short circuit current R.M.S. Value 500V 80kA 100kA and making capacity on Peak Value 500V 175kA 220kA fault level... R.M.S. Value 660V 50kA 100kA Peak Value 660V 105kA 220kA...with back up fuses of rating 125A 200A Maximum peak let through current 660V 18kA 40KA Rated short-time withstand current 1sec 660V 5kA 8kA Rated capacitor power note (3) 380V 50kVAr 90kVAr 415V 55kVAr 100kVAr 12
13 Mechanical / Electrical endurance 3-pole switch fuses 15000/ /1000 at rated current PF 0.65 Fuse types BS pattern BS88 A2-A4 B1-B2 distance of fixing holes 94mm 111mm Weight 3-pole switch fuses 2.1kg 6.9kg Notes: (1) Ambient temperature 60 C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link. 13
14 Switch Fuses Sizes 315A and 400A Catalogue Nos: CSSF315B3 and CSSF400B3 ASTA Certified to IEC Tested by TCA Lane Cove, Sydney Switch Sizes Sizes 315 and 400 BS Pattern Catalog No. CSSF315B3 CSSF400B3 Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 315A 400A current AC22 Ambient temp. 40 C In enclosure (no ventilation) 660V 290A 345A free mounting position. note (1) In enclosure (solid links) 660V 400A 450A Rated Operational voltage 660V 660V Rated operational current in categories 220V 315A 400A AC23 and AC3. Time interval between 380V 315A 400A 20 seconds in AC3. 415V 315A 400A 660V 315A 400A Rated operational current DC23 Two poles in series 110V 315A 400A Two poles in series 220V 315A 400A Three poles in series 440V 300A 400A Rated operational power in categories 220V 90kW 110kW AC23 and AC3. Time interval 380V 160kW 210kW between 415V 180kW 230kW 20 seconds in AC3 note (2) 500V 220kW 280kW 660V 290kW 330kW Rated breaking capacity 500V 3200A 3200A AC23.COSø = V 3200A 3200A Rated breaking capacity 110V 1600A 1600A DC, L/R = 15mS 220V 1600A 1600A 440V 1600A 1600A Rated fused short circuit current R.M.S. value 500V 100kA 100kA and making capacity on Peak value 500V 220kA 220kA fault level... R.M.S. value 660V 100kA 50kA Peak value 660V 220kA 105kA...with back up fuses of rating 315A 400A Maximum peak let through current 660V 45kA 45KA Rated short-time withstand current 1sec 660V 10kA 10kA Rated capacitor power note (3) 380V 145kVAr 180kVAr 415V 160kVAr 200kVAr 14
15 Mechanical / Electrical endurance 3-pole switch fuses 10000/ /1000 at rated current PF 0.65 Fuse types BS pattern BS88 B1-B3 B1-B4 distance of fixing holes 111mm 111mm Weight 3-pole switch fuses 7.3kg 7.8kg Notes: (1) Ambient temperature 60 C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link. 15
16 ASTA Certified to IEC Switch Fuses Sizes 630A and 800A Catalogue Nos: CSSF630B3 and CSSF800B3 Tested by TCA Lane Cove, Sydney Switch Sizes Sizes 630 and 800 BS Pattern Catalog No. CSSF630B3 CSSF800B3 Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 630A 800A current AC22 Ambient temp. 40 C In enclosure (no ventilation) 660V 560A 720A free mounting position. note (1) In enclosure (solid links) 660V 700A 900A Rated Operational voltage 660V 660V Rated operational current in categories 220V 630A 800A AC23 and AC3. Time interval between 380V 630A 800A 20 seconds in AC3. 415V 630A 800A 660V A Rated operational current DC23 Two poles in series 110V 630A 720A Two poles in series 220V 630A 800A Three poles in series 440V 630A 800A Rated operational power in categories 220V 180kW 200kW AC23 and AC3. Time interval 380V 315kW 350kW between 415V 340kW 380kW 20 seconds in AC3 note (2) 500V 400kW 470kW 660V 540kW 600kW Rated breaking capacity 500V 5040A 6400A AC23.COSø = V A Rated breaking capacity 110V 3200A 3200A DC, L/R = 15mS 220V 2500A 2500A 440V 2500A 2500A Rated fused short circuit current R.M.S.value 500V 80kA 80kA and making capacity on Peakvalue 500V 175kA 175kA fault level... R.M.S.value 660V 50kA 50kA Peakvalue 660V 105kA 105kA...with back up fuses of rating 630A 800A Maximum peak let through current 660V 50kA 65kA Rated short-time withstand current 1sec 660V 16kA 16kA Rated capacitor power note (3) 380V 250kVAr 310kVAr 415V 270kVAr 340kVAr 16
17 Mechanical / Electrical endurance 3-pole switch fuses 6000/ /500 at rated current PF 0.65 Fuse types BS pattern BS88 C1-C2 C1-C3 distance of fixing holes 133, 184mm 133, 184mm Weight Notes: 3-pole switch fuses 15.5kg 17.0kg (1) Ambient temperature 60 C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link. 17
18 Switch Fuses: Dimensions (mm) Switch Fuses Drawing Diagrams 1 CSSF32G1 CSSF63G1 Handle: YASDB20 Shaft: CSSFZS13 L = 185mm CSSF100G1 Handle: YASDB20 Shaft: CSSFZS13 L = 165mm CSSF200B3 Handle: YASDB16 Shaft: CSSFZS41 L = 255mm 18
19 Switch Fuses: Dimensions (mm) Switch Fuses Drawing Diagrams 2 CSSF315B3 CSSF400B3 Handle: YASDB16 Shaft: CSSFZK41 L = 255mm CSSF630B3 CSSF800B3 Handle: YASDA8/YASDB16 Shaft: CSSFZK41 L = 255mm 19
20 Switch Fuse Accessories Extended Shafts Shaft Dimension Switch Size Length (mm) Catalog No. 6mm square 32A to 125A 150mm CSSFZS13 430mm CSSFZS31 12mm square 200A to 800A 250mm CSSFZK41 465mm CSSFZK44 Auxiliary Contacts 32A to 63A 125A CSSFZX46 CSSFZX1 200 to 800A CSSFZX34 32A to 63A CSSFZX32 125A CSSFZX to 800A CSSFZX36 Terminal shrouds Poles Switch Type No. required Catalog No. 3-poles CSSF100GI 2 CSSZX8 3-poles CSSF200B3 2 CSSFZX70 CSSF250B3 3-poles CSSF315B3 2 CSSFZX72 CSSF400B3 3-poles CSSF630B3 6 CSSFZX104 CSSF800B3 Changeover Mechanisms Switch Type 32A to 125A 200A to 400A 630A to 800A Catalog No. CSSFZW1 CSSFZW12/1 CSSFZW12 Locking Attachment ETSF200 to 800A CSSDZW5 20
Panel Mount Switches
Panel Mount Switches Load Break Switches Fuse Switches Changeover Switches IPD Industrial Products is an Australian owned distributor of a wide variety of low voltage electrical and automation products
More informationTHE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions
THE SANTON FCS-TYPE SWITCH DISCONNECT Superior Switch Solutions The technical information given in this table applies to and pole fuse combination switches. A B NOMINAL RATING 0A A FUSE COMBINATION SWITCHES
More informationChangeover & Bypass Sw it ches
Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without
More information25A 25A 32A 40A 40A 63A 63A 80A
ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationPowerLine Switch Fuses OESA_PL, A. Contents: Technical data... 9/2. Ordering information DIN-pattern... 9/3 BS-pattern...
Switch Fuses ESA_PL, A Contents: Technical data... /2 rdering information DN-pattern... /3 BS-pattern... /3 Accessories... /4 Dimension Drawings... /6 /1 Technical Data Switch Fuses ESA Technical Data
More informationSwitch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV
Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads
More informationSwitch-disconnectors OT , OETL 3150
Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination
More informationDCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC
More information3NP1 Fuse Switch Disconnectors up to 630 A
Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors
More informationL O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR
L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR The safest way to switch power on and off in your industrial control panels. Your problem: You
More informationA compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.
PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants
More informationBreakers and Switches. Switches Switch-disconnectors OT and OTM
Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,
More informationNon-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.
disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationLow Voltage Products. Switches Switch-disconnectors OT and OETL
Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC lth /A le /AC22A, 415V le /AC23A, 415V... OT16F OT63F OT100F OT160E OT25F OT80F OT125F OT40F 25 32 40 63 80 115 125
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationIP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.
General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationSw it ch Disconnect ors
Switch Disconnectors St ate of the art Manufacturing Facilities Haridw ar, Noida PhI & Noida PhII Plant C&S Elect ric im i t ed Sw it ch Disconnect ors o 25 415V 50 C IP65 Introduction Rugged construction,
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationTechnical data OT16E3 OT160E3 UL & CSA
Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58
More informationSection Contents. Disconnect Switches
Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330
More informationIP20 degree of protection; IP40 degree of protection after installation in a distribution box
RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationSENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be
More informationEuroload Changeover Switch
Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationUL/CSA Non-fused Disconnect Switches
Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationAdak Behin Niroo. co.com
Adak Behin Niroo www.adakbn co.com PRODUCTS LOW VOLTAGE SWITCHGEARS MEDIUM VOLTAGE SWITCHGEARS PRODUCTS LOW VOLTAGE SWITCHGEARS www.adakbn co.com High Standard Type Tested Know How
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationLow Voltage Switches. Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM
Low Voltage Switches Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM Motorized switches OTM 60...2500, OSM 2...250 Contents Product overview 6 Features 8 Technical data 6
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationSwitch disconnectors
Selection Load break switch disconnectors type LK3, 40-120 A Selection guide for 3 and 4-pole switch disconnectors General The LK3 range of switch disconnectors (lth: 40 A to 120 A) is designed for use
More informationIndustrial contactors CTX-1
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical
More informationMoDPlus Din Distribution Boards
MoDPlus Din Distribution Boards Introduction MoDPlus DIN Distribution Panel Board System MoDPlus Din type Distribution Board System has been designed and developed locally, incorporating features and benefits
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationAbout us. Switchgear Factory, Mumbai
About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationCI-TI Contactors and Motor Starters Type CI 6-50
Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components
More informationSiemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage
SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution
More informationCat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationBulletin 194R Next Generation Global Fused and Non-Fused Disconnects
Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationSIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC
and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationAIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR
AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector
More informationSIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points
Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationCOMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33
BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationDX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data
Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC
More informationGeneral information about motor protection
Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch
More information(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB
Annexure-V (Under Two Part Bid System) Tender No: NFV/ PUR/ BEC 160546 K for VCB Technical specification for NIT SL NO 1 S.No. Description NFL requirement as per NIT Vendors Comment [Agreed / If not agreed,
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More informationApprovals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking
MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More information1489-M Circuit Breakers
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable
More informationTECHNICAL SPECIFICATIONS OF PCC PANEL
S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational
More informationTeSys GS. Data for Designers. Contents
TeSys GS Technical Data for Designers Contents Characteristics: > switch-disconnector... B5/16 to B5/21 > auxiliary contacts...b5/22 Dimensions... B5/23 to B5/31 Schemes...B5/31 B5/15 Characteristics -
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationLOAD BREAK SWITCHES AND SWITCH FUSES
easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationC60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V
DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More information