Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Size: px
Start display at page:

Download "Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR"

Transcription

1 Presentation type XCR b XCR v With head for rotary movement operators, spring return to off position contact actuation position per direction Page / v With head for rotary movement operators, stay put contact actuation position per direction Page / -EN_Ver..indd

2 Presentation (continued) types XCK MR and XCK VR For conveyor belt shift monitoring applications, type XCR T b XCK MR (metal) v With head for rotary movement operators, stay put mechanical actuation positions of contacts From to electrical positions depending on model Page / b XCK VR (plastic) v With head for rotary movement operators, stay put mechanical actuation positions of contacts From to electrical positions depending on model b XCR T Page / v With head for rotary movement operators, spring return to off position contact actuation positions per direction contact actuated at, other contact at Page / -EN_Ver..indd

3 General characteristics types XCR, XCK MR and XCK VR For conveyor belt shift monitoring applications, type XCR T Environment characteristics XCR and XCR T XCK MR (metal) XCK VR (plastic) Conformity to standards Products EN/IEC --, CS C- n, CCC Machine assemblies EN/IEC - EN/IEC --, CS C- n, UL, CCC Product certifications XCR,, E, F: e, CS, CCC, GOST e, UL, CS, CCC, GOST Protective treatment Standard version TC mbient air temperature For operation - + C - + C - + C For storage - + C - + C - + C Vibration resistance Shock resistance Conforming to EN/IEC -- Conforming to EN/IEC -- gn ( Hz) gn ( Hz) gn ( Hz) XCR,, E, F: gn, XCR T: gn ( ms) gn gn Electric shock protection Class I conforming to IEC Class II conforming to IEC Degree of protection Conforming to EN/IEC XCR,, E, F: IP XCR T: IP IP IP Degree of protection against Conforming to EN IK IK IK mechanical impacts Materials Enclosure Metal Zamak ZP (PT + PC) - GF FR (Valox) (except XCR T: polyester) Cover Metal DC steel (PT + PC) - GF FR (Valox) (except XCR T: polyester) Head Metal Zamak ZP (PT + PC) - GF FR (Valox) Cable entry Contact block characteristics Rated operational characteristics Conforming to EN/IEC -- ppendix tapped entry for n cable gland XCR,, E, F: a C-; (Ue = V, Ie = ), Ithe = c DC- ; Q (Ue = V, Ie =. ) XCR T: a C-; (Ue = V, Ie =. / Ue = V, Ie = ) c DC- ; R (Ue = V, Ie =. ) tapped entries for n cable gland or tapped M x. tapped entry M x.. breakout holes for ISO M cable gland a C- ; (Ue = V, Ie = ), Ithe = c DC- ; Q (Ue = V, Ie =. ) Rated insulation voltage Ui = V degree of pollution conforming to EN/IEC - Ui = V conforming to UL, CS C- n Rated impulse withstand voltage U imp = kv conforming to EN/IEC -, IEC Positive operation (depending on model) NC contacts with positive opening operation conforming to EN/IEC -- Section (except XCR T) NC contacts with positive opening operation conforming to EN/IEC -- Section (contacts ) Resistance across terminals y m Ω conforming to NF C - method or IEC - category Short-circuit protection cartridge fuse type gg (gl) Connection Screw clamp terminals Clamping capacity XEN P ou XCR T: min: x. mm, max: x. mm XES P: min: x. mm, max: x. mm Clamping capacity min: x. mm max: x. mm -EN_Ver..indd

4 General characteristics (continued) types XCR, XCK MR and XCK VR For conveyor belt shift monitoring applications, type XCR T Contact block characteristics (continued) Electrical durability b Conforming to EN/IEC -- ppendix C b Utilisation categories C- and DC- b Maximum operating rate: operating cycles/hour b Load factor:. C supply a / Hz inductive circuit Millions of operating cycles XES P Ithe V, V / V V,, Current in Millions of operating cycles XEN P,, Ithe V // V V,, Current in XCR T contacts Millions of operating cycles, Ithe / V V V, V, Current in DC supply c Voltage V Power broken in W for XES P million operating cycles XEN P W XCR T contacts For XES P on a or c NC and NO contacts simultaneously loaded to the values shown with reverse polarity. -EN_Ver..indd

5 type XCK MR and XCK VR Complete switches with cable entries Type of head Rotary References, characteristics Material Metal Plastic Type of operator With cruciform metal With cruciform metal With cruciform metal rods rods, reversed head rods References y pass switches x -pole NC+NO staggered, slow break (XE NP) XCK MRSRH XCK VRSRH With cruciform metal rods, reversed head Simple speed switches x -pole NC+NO staggered, slow break (XE NP) XCK MRDH XCK MRDH XCK VRDH XCK VRDH Double speed switches ( NC contact with positive opening operation on contacts ) x -pole NC+NC staggered, slow break (non interchangeable contacts) XCK MRDH () XCK MRDH () XCK VRDH XCK VRDH Weight (kg).... Complementary characteristics Switch actuation Horizontal Horizontal cceptable actuation area on the roads etween and mm from the axis of the fi xing screws of the body Minimum actuation speed m/mn m/mn Maximum actuation speed. m/s. m/s Minimum force or torque For tripping. N.m. N.m For positive opening. N.m. N.m Mechanical durability million operating cycles million operating cycles Setting up Rods included with the switch: for customer assembly References of separate components XCR Z XCR ZR Description Reference Weight kg Rod U mm, L = mm XCR Z. Rod U mm, L = mm with red mark XCR ZR. Plastic cable gland ISO M DE PEM. DE PEM () For switches with entry for Pg. cable gland, delete H from the end of the reference. Example: XCK MRDH becomes XCK MRD. () For an actuation point on the rod between and mm from the axis of the fi xing screws of the boby. -EN_Ver..indd

6 Dimensions type XCK MR and XCK VR Complete switches with cable entries Dimensions Metal limit switches XCK MRSRH, XCK MRDH and XCK MRDH XCK MRDH and XCK MRDH,,,,, () () ' () =, = (), () XCK MRppppH = tapped entries ISO M x.. XCK MRppp = tapped entries for n cable gland. () centring holes Ø. ±., for cover fi xing holes alignment. Ø: elongated holes. x., inclined at to the vertical axis, for M screws. Plastic limit switches XCK VRSRH, XCK VRDH and XCK VRDH XCK VRDH and XCK VRDH,,,,, () () tapped entry ISO M x.. () breakout holes for ISO M cable gland (reference: DE PEM). Ø: elongated holes. x., inclined at to the vertical axis, for M screws. ' () =, = () -EN_Ver..indd

7 Operation type XCK MR and XCK VR Complete switches with cable entries Operation XCK prsrh: y pass () Contact Contact Contact Contact Contact Contact Contact Contact Contact Contact () Triangle symbol marked on top of head. or : direction of rotation. XCK prdph: simple speed () Contact Contact Contact Contact Contact Contact Contact Contact Contact Contact () Triangle symbol marked on top of head. or : direction of rotation. -EN_Ver..indd

8 Operation (continued) type XCK MR and XCK VR Complete switches with cable entries Operation (continued) XCK prdpppp: double speed () Contact Contact Contact Contact Contact Contact Contact Contact Contact Contact () Triangle symbol marked on top of head. or : direction of rotation. -EN_Ver..indd

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR Presentation For hoisting and material handling applications XCR b XCR v With head for rotary movement operators, spring return to off position 1 contact actuation position per direction Page 326/6 v With

More information

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

Limit switches 3. Page 92. Page 92

Limit switches 3. Page 92. Page 92 Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards

More information

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK

More information

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR. Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with

More information

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry References, characteristics For hoisting and materials handling applications, type XCR Complete switches with cable entry Type of head Rotary with spring return to off position Stay put Maximum displacement

More information

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

Components for safety applications

Components for safety applications Presentation CS-P with 1 cable entry With rotary operating head, with elbowed lever (flush with rear of switch) straight lever, f hinged covers and guards Pages /4, /4, /44 CS-PR with 1 cable entry With

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit

More information

K50F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K63F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air

More information

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT OsiSense XC Basic Limit Switches XCMN, XCKN, XCNT Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com - www.stevenengineering.com Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com

More information

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Complementary Possible differential minimum at low setting Possible differential minimum at high setting Maximum permissible

More information

Safety detection solutions

Safety detection solutions General, Preventa XY C Presentation are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which could cause injury to persons or damage either to machines

More information

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Main Range of product Product or component type Pressure sensor type Device short name Pressure sensor size Controlled

More information

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device

More information

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Product availability : Non-Stock - Not normally stocked in distribution facility Main Range of product Product or component

More information

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Product availability : Stock - Normally stocked in distribution facility Main Range of product Product or component type Pressure

More information

Pendant control stations

Pendant control stations : pages 30075/3 to 30075/6 Characteristics Environment Conforming to standards IEC 947-5-1, EN 60 947-5-1, IEC 337-1, VDE 0660-200 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600,

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-N Series Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms

More information

Limit switches 0 ZCK E67 ZCK E23 ZCK E62. with contact, cable. entry for Pg 13, fi xed, 1 step (2) (3) ZCK JD3p, ZCK J1, J5, J6, J7, J9

Limit switches 0 ZCK E67 ZCK E23 ZCK E62. with contact, cable. entry for Pg 13, fi xed, 1 step (2) (3) ZCK JD3p, ZCK J1, J5, J6, J7, J9 Presentation Variable composition: standard bodies Thermoplastic roller lever plunger, 1 direction of actuation Steel roller lever plunger, 1 direction of actuation ZCK E1 ZCK E3 Side metal plunger Side

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Rotary limit switches FCR FGR series

Rotary limit switches FCR FGR series Rotary limit switches FCR FGR series Rotary control switches with 00mm rods from up to positions. Control switches with rotary gear from up to 00 rpm with or micro switches. 0 Rotary limit switches FCR

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons haracteristics pendant control station XA-A - 8 pushbuttons Main Range of product Product or component type Device short name omplementary ontrol station type Enclosure material Electrical circuit type

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Cam switches 3. General 3. Complete switches. Ø 16 or Ø 22 hole fixing

Cam switches 3. General 3. Complete switches. Ø 16 or Ø 22 hole fixing General Cam switches Complete switches, A The range K cam switches ( A rating) comprises only complete switches. These products are more specifi cally designed for process control applications: b compact

More information

Screw limit switches XRBA and XR2. Catalogue

Screw limit switches XRBA and XR2. Catalogue XRBA and XR2 Catalogue Contents XRBA and XR2 Selection guide.............................................. page 2 for standard duty: XRBA Presentation.............................................. page

More information

Pre wired limit switches

Pre wired limit switches Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66

More information

FOOT SWITCHES

FOOT SWITCHES - 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

Limit switches. Steel roller plunger. Metal end plunger with elastomer boot 4.6(P) mm

Limit switches. Steel roller plunger. Metal end plunger with elastomer boot 4.6(P) mm characteristics Complete switches with cable entry Type of head Plunger (fixing by the body) Form B () Form C () Form E () with elastomer boot Steel roller References of complete switches with ISO M x

More information

Miniaturized limit switches

Miniaturized limit switches Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches

More information

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Product Description They are developed in order to be used for following operations: For monitoring and protection of industrial machines,

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Limit switches Osiswitch Classic Metal, conforming to CENELEC EN 50041, type XCK J Fixed or plug-in body Variable composition: standard bodies

Limit switches Osiswitch Classic Metal, conforming to CENELEC EN 50041, type XCK J Fixed or plug-in body Variable composition: standard bodies Presentation Metal, conforming to CENELEC EN 41, type XCK J Variable composition: standard bodies ZCKE1 ZCKE ZCKE63 ZCKE64 ZCKE6 ZCKE8 ZCKE6 ZCKE67 ZCKE69 ZCKE61 ZCKE66 ZCKE619 ZCKJ1D, JD, J6D, J7D ZCKJ8D

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

LR-LX-LK-LW Safety Switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

Safety rope switch without reset for simple stop

Safety rope switch without reset for simple stop afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Limit Switch - Prewired Type Metal Body

Limit Switch - Prewired Type Metal Body Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation

More information

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A Characteristics power relay plug-in - Zelio RPF - 2 NO - 120 V AC - 30 A Product availability : Stock - Normally stocked in distribution facility Price* : 12.69 USD Main Range of product Series name Product

More information

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Limit Type (PS21L) Metal Body IP66 Limit Switches - Limit Type (PS21L) Metal Body IP66 High mechanical resistance Degree of protection IP66 Zinc alloy (Zamack) or aluminium body Positive Opening Operation Minimum Actuation Force/Torque

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

Position switches FC series

Position switches FC series A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

PRODUCT SPECIFICATION. Foot Switches. Series.

PRODUCT SPECIFICATION. Foot Switches. Series. PRODUCT SPECIFICATION Foot 46 Series www.wernerelektrik.com Foot Switch Structures...1 Technical Data...2 Model Number Structure - Foot...3 Dimensions...4 Precautions... Foot WERNERS are Rigorous and tough.

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

Rope safety switches with reset for emergency stop

Rope safety switches with reset for emergency stop Rope safety switches with reset for emergency stop Description and technical data hese rope operated safety switches are installed on machines or conveyor belts, to activate the emergency stop of the machine

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Microswitches MK series

Microswitches MK series Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with

More information

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

LS Series Limit Switches. Short Form Catalogue AC1300 ABB Short Form Catalogue LS Series Limit Switches AC ABB LS Series Limit Switches Foot Switches Contents Panorama... 2 Limit Switches - Plastic Casing and Metal Casing... 12 Safety Limit Switches - Plastic

More information

e.

e. e. e. e. e. e. e. e. e. e. e. Characteristics Control and signalling units Ø 220 Harmony XB7 Monolithic pushbuttons, switches and pilot lights 1 2 Environment Protective treatment Standard version TH Ambient

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B 3 H G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65 Limit Switches - Limit Type (PSL) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4JL D4JL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Holding

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm Limit Switches casing, 3mm, 4mm & 6mm Description are made of aluminum alloy and have a degree of protection of IP 66 and UL type 4X. The casings come in 3 dimensions: LS3M, 3mm width. LS4M, 4mm width.

More information

ZCK-Y39 ZCK-Y49 ZCK-Y33 ZCK-Y34 ZCK-Y31 ZCK-D109 ZCK-D41 ZCK-D06 ZCK-M2H29 ZCK-M2H29

ZCK-Y39 ZCK-Y49 ZCK-Y33 ZCK-Y34 ZCK-Y31 ZCK-D109 ZCK-D41 ZCK-D06 ZCK-M2H29 ZCK-M2H29 ZCK-Y39 ZCK-Y43 ZCK-Y49 ZCK-Y41 ZCK-D239 ZCK-D23 ZCK-D59 ZCK-Y55 ZCK-Y54 ZCK-Y59 ZCK-D219 ZCK-D21 ZCK-D81 ZCK-D91 ZCK-Y91 ZCK-Y31 ZCK-Y33 ZCK-Y34 ZCK-Y81 ZCK-D029 ZCK-D02 ZCK-D05 ZCK-D109 ZCK-D41 ZCK-D06

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E0 I E20 I E40 I Contact blocks (standard) M20 ½ NPT 00 NO+NC snap action 0 NO+NC slow action 02 NO+NC slow action with

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Components for safety applications

Components for safety applications pages / and /35 page /36 Double insulated, turret head, types CS-PA, CS-TA and CS-TE Cable entries tapped M16 x 1.5 Without locking of actuator 1 -pole N/C + N/O CS-PA59 -pole N/O + N/C CS-PA69 -pole N/C

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65 Limit Switches - Limit Type (PS42L) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches HSC HSC Full Size Solenoid Locking Switches Key features: Rugged aluminum die-cast housing 00N locking retention force Flexible Installation: The actuator can be accessed from two directions Select from

More information

Safety Limit Switches

Safety Limit Switches Safety Limit Switches with separate actuator Z02: Snap action 2NC Y+Y 3 Bent key 4 Flat key 5 Bent key 6 Flat key 7 Shock absorbing bent key 8 Shock absorbing flat key 9 Adjustable joint key Z11: Snap

More information

Single foot switches - PX and PA series

Single foot switches - PX and PA series Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified

More information

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X. Limit switches pre-wired 3mm & 35mm Metal & plastic casings Limit switches Description Plastic are made of reinforced UL-VO thermoplastic fiberglass, offering double insulation and protection

More information

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic Safety switches Selection diagram Actuators AB BB CB TB S5 SC Thermoplastic Bodies E0 I E20 I E0 I Contact blocks 0 NO+NC slow action 0 2NC slow action 08 2NC slow action (for pull-wire switches) Pg 3,5

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information