Safety detection solutions

Size: px
Start display at page:

Download "Safety detection solutions"

Transcription

1 General, Preventa XY C Presentation are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which could cause injury to persons or damage either to machines or work in progress, b be tripped by a single human action when a normal Emergency stop function is not available, b trip in the event of the rope pull breaking. are essential in premises and on machines that are potentially dangerous when in operation. The operator must be able to trigger the stop instruction at any point within their working area. Application examples: woodworking machines, shears, conveyor systems, transfer machines, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works. Installation Typical installation Fixing support First cable support Turnbuckle Pulley supports and pulleys End spring grips Switch adjustment Emergency stop Notes regarding installation b All XY CH and XY CE rope pull switches can be fi tted with a pilot light to indicate their tripped condition. b tension adjustment can be performed using: v a turnbuckle (to be ordered separately, see page /), v a tensioner (integrated in certain XY CH models, see page /). b This adjustment is simplifi ed by: v a cable tension indicator that is available on all models XY CH, v the availability of versions with a cable tension indicator window by stating its reference on the order form (see page /). Example: reference XY CEA0 becomes XY CED0. b The use of an end spring is strongly advised for conveyor system applications to ensure operation of the Emergency stop in the event of the cable being pulled towards the switch. b It is essential that pulleys be used with ropes pull that deviate from a straight run, i.e. angled to form a protected zone. b Important: switches XY CH and XY CE can be used if the installation requires that the rope pull be angled. In this case, the total sum of the angles through which the rope pull bends must not exceed 0. (For further information on instructions to be adhered to, please refer to the installation manual). Characteristics: page / References: page / Dimensions: page / -EN_Ver.0

2 General (continued), Preventa XY C Main features Rope pull expansion and contraction: d Positive operation: running condition Latching: stop instruction given (tripped) Resetting: stop condition (awaiting reset/restart) The switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action. The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling. The switches incorporate a reset button, which re-closes the safety contact(s). Restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the rope pull switch. Temperature variations likely to be encountered in the protected zone will obviously cause the rope pull to expand or contract. To enable instant verifi cation that the rope pull is at its correct tension (and for making any necessary adjustments), rope pull switches XY CH and XY CE incorporate a rope pull tension indicator. d (mm) Standards Rope pull switches Preventa XY CH and XY CE meet all the requirements of the harmonised European standard EN/ISO 0, relating to Emergency stop devices. All the rope pull switches are e marked and supplied with an EC declaration of conformity. -EN_Ver.0

3 General (continued), Preventa XY C Tripping force: F Tripping deflection: f The tripping force F is the force necessary on the rope pull to cause the switch to trip. The tripping defl ection f is the distance that the rope pull has to be defl ected from its taut position to the point at which the switch trips. f F Type Position of cam Max. End spring length of cable Average tripping deflection values f and tripping forces F for a distance of m between cable supports and cable used Force F (dan) Deflection f (mm) for: Standard Light Standard force Light force Ø. mm Ø mm Ø. mm Ø mm Ø. mm Ø mm Ø. mm Ø mm XY CH 0 m XY CZ XY CE A 0 m XY CZ B C D E Adjustment values (with end spring) F For Preventa XY CE: the adjustment values depend on the positions of the cam located inside the switch. Adjustment is made by rotating the cam after the switch has been installed. Each notched position of the cam is referenced by the letters A to F, and the selected letter is visible through a viewing port. Temperature range: < C. XY CH C m XY CE C L (m) ABCDEF m L (m) Characteristics: page / References: page / Dimensions: page / -EN_Ver.0

4 Characteristics Preventa XY C Environment Conformity to standards Products XY CH, XY CE: EN/IEC 0--, EN/ISO 0: 00, UL 0 and CSA C - n (with suffix H) Machine assemblies XY CH, XY CE: EN/IEC 00-, Machinery directive: 00//EC, Work equipment directive: //EEC Product certifications XY CH: UL-CSA (with suffi x H), CCC () XY CE: UL-CSA A 00-Q 00 (with suffi x H), CCC Maximum safety level () PL e, category conforming to EN/ISO - and SIL conforming to EN/IEC 0 Reliability data B d XY CH:,000,000 XY CE: 0,000 (data values for a service life of 0 years: can be limited by contact and mechanical wear) Protective treatment Standard version TC Special version TH Ambient air temperature For operation C For storage C Vibration resistance XY CH: gn ( 0 Hz) XY CE: gn ( 00 Hz) conforming to EN/IEC 00-- Shock resistance XY CH, XY CE: 0 gn (duration ms) conforming to EN/IEC 00-- Electric shock protection Class I conforming to IEC 0 Degree of protection XY CH, XY CE: IP conforming to IEC 0 Mechanical life XY CH: million operating cycles XY CE:,000 operating cycles Length of protected zone (rope pull) XY CH: y 0 metres, XY CE: y 0 metres Distance between cable supports m entries XY CH: threaded entries with Pg., ISO M0 or / NPT. XY CE: plain holes with Pg., ISO M0 or / NPT. See dimensions, page /. Contact block characteristics Rated operational characteristics -pole contacts -pole contacts XY CH, XY CE: AC-: A00 or Ue = 0 V, le = A DC-: Q00 or Ue = 0 V, le = 0. A, conforming to EN/IEC 0-- Appendix A XY CH, XY CE: AC-: C00 or Ue = 0 V, le = 0. A DC-: R00 or Ue = 0 V, le = 0. A, conforming to EN/IEC 0-- Appendix A A Nominal thermal current Rated insulation voltage -pole contacts XY CH, XY CE: Ui = 00 V degree of pollution conforming to EN/IEC 0-, Ui = 00 V conforming to UL 0, CSA C- n -pole contacts XY CH, XY CE: Ui = 00 V degree of pollution conforming to EN/IEC 0-, Ui = 00 V conforming to UL 0, CSA C- n Rated impulse withstand -pole contacts XY CH, XY CE: Uimp = kv conforming to EN/IEC 0- voltage -pole contacts XY CH, XY CE: Uimp = kv conforming to EN/IEC 0- Positive operation NC contact with positive opening operation conforming to EN/IEC 0-- Section Contact operation XY CH, XY CE (Emergency stop) Resistance across terminals y mω conforming to NF C -00 method A or EN/IEC 0- category Terminal referencing Conforming to CENELEC EN 00 Short-circuit protection -pole contacts XY CH, XY CE: A cartridge fuse type gg (gl) conforming to IEC 0 -pole contacts XY CH, XY CE: A cartridge fuse type gg (gl) conforming to IEC 0 Rated operational power (Electrical durability) Operating rate: 00 operating cycles/hour Load factor: 0, XY CH, XY CE Conforming to EN/IEC 0-- Appendix C. Utilisation categories AC- and DC- AC supply a 0/0 Hz o Inductive circuit Millions of operating cycles 0, 0 V Ithe // V V 0, A Current in A Contact connection Voltage V 0 o W 0 Screw clamp terminals Clamping capacity: min. x 0. mm, max. x. mm Minimum tightening torque: 0. N.m Maximum tightening torque:. N.m () Only products XY CH without pilot light are CCC and UL-CSA approved. () Using an appropriate and correctly connected control system. -EN_Ver.0

5 References Preventa XY C Latching Emergency stops (Pg., integrated turnbuckle, cable and end spring to be ordered separately) () Without pilot light Length of cable Colour of enclosure Reset Supply voltage Type of contact anchor point Reference Weight 0 XY CH0 XY CEA0 y 0 m Red RAL 000 body and stainless steel cover By mushroom head By key operated (key n ) () By fl ush By mushroom head By key operated (key n ) () By fl ush By mushroom head With pilot light (direct supply) y 0 m Red RAL 000 body and stainless steel cover NC + NO Both sides XY CH0 () 0. (right or left) XY CH0 () 0.00 XY CH0 () 0. NC + NC Both sides XY CH0 () 0. (right or left) XY CH0 () 0. XY CH0 () 0. XY CH0 () 0. NC + NO Both sides XY CH0 r () 0. (right or left) XY CH0 r () 0. XY CH0 r () 0. V NC + NO NC + NC NC + NO Latching Emergency stops (turnbuckle, cable and end spring to be ordered separately) () Without pilot light y 0 m () Red RAL 000 body and stainless steel cover With pilot light (direct supply) y 0 m () Red RAL 000 body and stainless steel cover By key switch (key n ) NC + NO NC + NC NC + NO NC + NC to 0 V NC + NO 0 to 0 V NC + NO Both sides XY CH 0.00 (right or left) XY CH 0.00 XY CH r 0.0 Right side XY CEA0 ().0 Left side XY CEA0 ().0 Right side XY CEA0 ().0 Left side XY CEA0 ().0 Right side XY CEA0 (). Left side XY CEA0 (). Right side XY CEA0 ().0 Left side XY CEA0 ().0 Right side XY CEA.0 Left side XY CEA.0 Right side XY CEA.0 Left side XY CEA.0 Other versions See order forms on pages / and /. XY CE with reset by Ø 0 mm mushroom head or with integral cable tensioner and support. Please consult our Customer Care Centre. () See separate components, page /. () Ø 0 spring return key operated. () For ISO M0 threaded cable entry version, add H to the end of the reference selected. Example: XY CH0 becomes XY CH0H. () Available with window for viewing cable tension indicator, for adjustment whilst the cover is closed (see versions XY CEpDppp and XY CEpEppp on the order form, page /). () ATEX version available (products for explosive atmospheres): To order, add EX to the end of the reference. Example: XY CEA0 becomes XY CEA0EX. r: Available st quarter 0. -EN_Ver.0

6 Order form (specimen suitable for photocopying) Preventa XY C Complete units, pre-assembled Customer Schneider Electric Industries SA Company Order N Delivery date Sales offi ce - Subsidiary Co. Order N XY CH0 How to use this form: - indicate the number of Emergency stop switches required, - complete the basic reference. Reference Number of identical Emergency stops XY CH Model Emergency stop (latching) Degree of protection IP (standard bellows) with integral tensioner IP (silicone bellows) with integral tensioner Type of reset Emergency stop () Reset by spring return Flush Booted Mushroom head, Ø 0 Key operated mushroom head, Ø 0 (key n ) Key operated mushroom head, Ø 0 (key n ) Key operated mushroom head, Ø 0 () Contact blocks for Emergency stop function () Slow break NC + NO (NO staggered) NC NC + NO Pilot light Without pilot light 0 With V direct supply pilot light With V direct supply pilot light With 0 V direct supply pilot light With 0 V direct supply pilot light Tapped cable entry /" NPT () H ISO M0 H Increased protection Treatment against corrosion () TK () Opening of a circuit + mechanical latching in the open position. () Other key numbers: A, 0E, A, E, A, A, E, E and E. () can only be fi tted with contact blocks. () Only for versions without pilot light. For versions with pilot light, order an H version. () Protective treatment TK is only possible for switches with silicone bellows (XY CHpppTK, XY CHpppHTK, etc). -EN_Ver.0

7 Order form (specimen suitable for photocopying) Preventa XY C 0 Complete units, pre-assembled Customer Schneider Electric Industries SA Company Order N Delivery date Sales offi ce - Subsidiary Co. Order N XY CEA0 How to use this form: - indicate the number of Emergency stop switches required, - complete the basic reference. Reference Number of identical Emergency stops XY CE Models Emergency stop (latching) Anchor point on right side, standard force Anchor point on left side, standard force Anchor point on right side, light force Anchor point on left side, light force Degree of protection and cable tension indicator window IP (standard bellows) without cable tension indicator window IP (silicone bellows) without cable tension indicator window IP (standard bellows) with cable tension indicator window IP (silicone bellows) with cable tension indicator window A C D E Type of reset Emergency stop () Flush Reset by spring Booted return Mushroom head, Ø 0 Emergency stop () Key n Reset by Key n key switch Key A or 0E Contact blocks for Emergency stop function () Slow break NC + NO NC NC + NO (compulsory with pilot light) () Pilot light Without pilot light 0 Protected LED, - 0 V supply voltage pilot light (provide for contact blocks) Protected LED, 0 V supply voltage pilot light (provide for contact blocks) Version for North American countries Tapped cable entry / NPT H Increased protection Treatment against corrosion () TK () Opening of NC contact + mechanical latching in the open position. () can only be fi tted with contact blocks. () The use of a pilot light means selecting a switch fi tted with NC + NO contacts: XY CEpppp. () Protective treatment TK is only possible for switches with silicone bellows (XY CEpCpppTK, XY CEpEpppHTK). -EN_Ver.0

8 References Preventa XY C 00 XY CZ0 Separate components Description For use with Diameter mm Galvanised cables with red sheath XY CH and XY CE Length m Reference Weight.. XY CZ XY CZ XY CZ XY CZ0.0 XY CZ0 0. XY CZ.00. XY CZ 0.0. XY CZ XY CZ.0 00 XY CZ0 0 Description Type For use with Sold in lots of Tensioner (included in mounting kit XY CZ) 0. XY CZ.00 Unit reference Weight XY CE XY CZ XY CZ XY CZ0 Turnbuckles M x 0 + locknut All models () XY CZ M x 0 + locknut All models () XY CZ grips Single Ø to mm XY CZ Double Ø to mm XY CZ 0.0 Clamp Ø. mm XY CZ 0.00 Ø mm XY CZ supports Fixed All models XY CZ Swivelling All models XY CZ0 0.0 XY CZ0 XY CZ0 Pulley support XY CH and XY CE XY CZ Pulley Ø mm max. XY CH and XY CE XY CZ end protectors Ø. mm XY CZ Ø mm XY CZ End springs XY CH XY CZ0 0.0 XY CZ0 0 XY CZ0 Mounting kits Contents For use with diameter XY CE XY CZ Length of cable Reference Weight 00 mm m tensioner + bracket XY CE XY CZ 0. XY CZ0 galvanised cable + cable grip XY CZ + end spring XY CZ0 XY CH. XY CZ 0. XY CZ 0. DF galvanised cable + cable grips XY CZ + turnbuckle XY CZ0 + cable support XY CZ0 + cable end protectors XY CZ0 + end spring XY CZ0 XY CE. XY CZ XY CE. 0 XY CZ0.0 XY CZ galvanised cable + cable grips XY CZ + turnbuckle XY CZ0, + cable support XY CZ0 + cable end protectors XY CZ0 + end spring XY CZ0. XY CE XY CZ.0 0 XY CZ0.0 Documentation Description For use with Reference Weight Installation manual XY CH and XY CE XCOM 0.00 () XY CHppp and XY CHppp incorporate a cable tensioner as standard. Therefore, there is no need to order a turnbuckle. General: pages / to / Characteristics: page / Dimensions: page / -EN_Ver.0

9 References (continued) Preventa XY C Replacement parts Description For use with Type Reference Weight Reset (blue), spring return XY CH Flush with R marked on push ZB AA 0.00 Booted ZB AP 0.0 Mushroom head, Ø 0 ZB AC 0.0 XY CE Flush with R marked on push ZB AA 0.0 Booted ZB APS 0.0 Mushroom head, Ø 0 ZB AC 0.0 Key switch XY CH and XY CE With key n ZB AGR 0.0 With key n ZB AGR 0.0 Keys for reset button All types of Emergency stop N Q N Q Pilot light head assembly XY CE Orange XY CZ Red XY CZ Pilot light lens XY CH Orange ZB BV Fixing nut, plastic, grey XY CH and XY CE ZB AZ Fixing nut tightening key, plastic, grey XY CH and XY CE For fi xing nut ZB AZ0 Description For use with Voltage Sold in lots of Pilot lights With bulb DL AAppp included XY CH Colour: orange ZB AZ0 0.0 Unit reference Weight V XY CZ00 () 0.0 V XY CZ00 () V XY CZ00 () V XY CZ00 () 0.0 XY CZpppp Supply on LED XY CE Colour: red V ZAL VB V ZAL VG to 0 V ZAL VM 0.0 XY CE Colour: orange V ZAL VB V ZAL VG 0.0 Incandescent bulbs, screw base fitting 0 to 0 V ZAL VM 0.0 XY CH V - W DL AA V - W DL AA V - W DL AA Packet of collars For mounting DL AA and DL AA0 bulbs in pilot lights XY CZppp XY CZ0 0.0 () Only for use as replacement parts for switches pre-fi tted with pilot lights. CCC and UL-CSA approvals no longer apply if an XY CZppp pilot light is mounted on Emergency stops XY CH. General: pages / to / Characteristics: page / Dimensions: page / -EN_Ver.0

10 Dimensions Preventa XY C Latching Emergency stops XY CH Without pilot light With pilot light () (), () (), () Maximum extension. () Tapped entries for n (Pg.) cable gland. For ISO M0 the reference becomes XY CHpppppH. () mm: V and V versions. mm: 0 V and 0 V versions. XY CE XY CEAppp (anchor point on right side) XY CEpAppp + XY CZ (tensioner + bracket) Accessories XY CZ0 XY CZ0 M Ø () () 0 () 0 () () 0 () 0 () (), () 0 () () Ø 0 () () plain holes for n (Pg.) or ISO M0 cable gland. () Maximum extension. Ø: elongated holes Ø mm. General: pages / to / Characteristics: page / -EN_Ver.0

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR. Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

Limit switches 3. Page 92. Page 92

Limit switches 3. Page 92. Page 92 Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR Presentation type XCR b XCR v With head for rotary movement operators, spring return to off position contact actuation position per direction Page / v With head for rotary movement operators, stay put

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK

More information

e.

e. e. e. e. e. e. e. e. e. e. e. Characteristics Control and signalling units Ø 220 Harmony XB7 Monolithic pushbuttons, switches and pilot lights 1 2 Environment Protective treatment Standard version TH Ambient

More information

Pendant control stations

Pendant control stations : pages 30075/3 to 30075/6 Characteristics Environment Conforming to standards IEC 947-5-1, EN 60 947-5-1, IEC 337-1, VDE 0660-200 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600,

More information

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR Presentation For hoisting and material handling applications XCR b XCR v With head for rotary movement operators, spring return to off position 1 contact actuation position per direction Page 326/6 v With

More information

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Complementary Possible differential minimum at low setting Possible differential minimum at high setting Maximum permissible

More information

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Main Range of product Product or component type Pressure sensor type Device short name Pressure sensor size Controlled

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Components for safety applications

Components for safety applications Presentation CS-P with 1 cable entry With rotary operating head, with elbowed lever (flush with rear of switch) straight lever, f hinged covers and guards Pages /4, /4, /44 CS-PR with 1 cable entry With

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Product availability : Non-Stock - Not normally stocked in distribution facility Main Range of product Product or component

More information

K50F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K63F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Product availability : Stock - Normally stocked in distribution facility Main Range of product Product or component type Pressure

More information

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT OsiSense XC Basic Limit Switches XCMN, XCKN, XCNT Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com - www.stevenengineering.com Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Screw limit switches XRBA and XR2. Catalogue

Screw limit switches XRBA and XR2. Catalogue XRBA and XR2 Catalogue Contents XRBA and XR2 Selection guide.............................................. page 2 for standard duty: XRBA Presentation.............................................. page

More information

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66

More information

Cable (Rope) Pull Switches Lifeline 4

Cable (Rope) Pull Switches Lifeline 4 Emergency Stop Devices Description The cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The is the only

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Product Description They are developed in order to be used for following operations: For monitoring and protection of industrial machines,

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons haracteristics pendant control station XA-A - 8 pushbuttons Main Range of product Product or component type Device short name omplementary ontrol station type Enclosure material Electrical circuit type

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

LR-LX-LK-LW Safety Switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

Pre wired limit switches

Pre wired limit switches Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information

Miniaturized limit switches

Miniaturized limit switches Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

FOOT SWITCHES

FOOT SWITCHES - 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-N Series Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N

More information

Position switches FC series

Position switches FC series A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry References, characteristics For hoisting and materials handling applications, type XCR Complete switches with cable entry Type of head Rotary with spring return to off position Stay put Maximum displacement

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms

More information

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Limit Type (PS21L) Metal Body IP66 Limit Switches - Limit Type (PS21L) Metal Body IP66 High mechanical resistance Degree of protection IP66 Zinc alloy (Zamack) or aluminium body Positive Opening Operation Minimum Actuation Force/Torque

More information

Safety rope switch without reset for simple stop

Safety rope switch without reset for simple stop afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE

More information

SPECIAL DUST EXPLOSIVES ATMOSPHERES

SPECIAL DUST EXPLOSIVES ATMOSPHERES SPECIAL DUST EXPLOSIVES ATMOSPHERES Explosive atmospheres Main sectors of activity subject to a higher risk of explosion or fire Flour mills Wood and aluminium workshops A reference for installations in

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product

More information

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b

More information

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic Safety switches Selection diagram Actuators AB BB CB TB S5 SC Thermoplastic Bodies E0 I E20 I E0 I Contact blocks 0 NO+NC slow action 0 2NC slow action 08 2NC slow action (for pull-wire switches) Pg 3,5

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Limit Switch - Prewired Type Metal Body

Limit Switch - Prewired Type Metal Body Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

PRODUCT SPECIFICATION. Foot Switches. Series.

PRODUCT SPECIFICATION. Foot Switches. Series. PRODUCT SPECIFICATION Foot 46 Series www.wernerelektrik.com Foot Switch Structures...1 Technical Data...2 Model Number Structure - Foot...3 Dimensions...4 Precautions... Foot WERNERS are Rigorous and tough.

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65 Limit Switches - Limit Type (PS42L) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

Door Interlock Switches

Door Interlock Switches HS5B Series HS5B Series Miniature Interlock Switch HS5B features: mm x mm x 9mm Compact Housing Available with Contact Confi gurations (NO + NC or NC) Flexible Installation: By turning the head of the

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

XAL control stations for Harmony style 5 Ø 22 control and signalling units with double insulated bezel Complete stations (screw clamp connections)

XAL control stations for Harmony style 5 Ø 22 control and signalling units with double insulated bezel Complete stations (screw clamp connections) pages /2 and / pages /4 and /5 Complete stations (screw clamp connections) References Start or function (light grey base RAL 705, dark grey lid RAL 7016 ) Description Type Contact type Marking Reference

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E0 I E20 I E40 I Contact blocks (standard) M20 ½ NPT 00 NO+NC snap action 0 NO+NC slow action 02 NO+NC slow action with

More information

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65 Limit Switches - Limit Type (PSL) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

Automation - Lift - Handling System - Atex

Automation - Lift - Handling System - Atex Automation Lift Handling System Atex GIOVENZANA INTERNATIONAL B.V.: AUTOMATION TECHNOLOGIES AUTOMATION The solutions offered by Giovenzana are the results of the market analysis of industrial electrical

More information

Single foot switches PX and PA series

Single foot switches PX and PA series Single foot switches PX and PA series Technical data Housing Made of polymer glass-reinforced shock-proof thermoplastic resin with double insulation Bedplate with non-skid rubber feet. Actuation force:

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information