Micro-venturis, series GVA
|
|
- Matthew Lee
- 6 years ago
- Views:
Transcription
1 Micro-venturis, series GVA Reference V : vacuum outlet Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. or Male coupling, 4 mm dia.,. mm long ø Version GVA GVASIL or GVASPO ø 4. Venturi exhaust. Vacuum ø * 6.8 *Dimension of GVASIL C.A. inlet, bars Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. Reference P : pressure Applications : The mini-venturis in series GVA are especially suitable for robotic use owing to their light weight and rapid response time. Their design based on thermoplastic material preserves their excellent mechanical characteristics while providing economic vacuum-operated handling solutions. Characteristics : Characteristics Nozzle Air Maximum Drawn-in At air ø consumption vacuum air pressure Models mm Nl/min % Nl/min bar GVA 7 (blue).7 8 GVA 9 (grey) Specifications : Compressed air Filtered, non-lubricated, pressure to 6 bars Temperature - to 8 C Material Polyacetal (POM), blue for GVA 7 or grey for GVA 9 Weight g Insert M Brass - On option: stainless steel Fitting of optional equipment : Fitting of silencer GVASIL or GVASPO Connection for exhaust collection GVAC Vacuum data connector GVAV Manifold installation GVAG Vacuum filter GVA F8. See options on page. GVA : Nozzle diameter 7.7 mm (blue) 9.9 mm (grey) See curves GVA, S, B and D on page. Attachment of venturi : Clamp, ref. GAV.F Supplied in sets of. : Connection M M female, C.A. and vacuum MI M female, C.A. and vacuum, stainless steel 4 Tube.7/4 mm, C.A. and vacuum 44 Tube.7/4 mm, C.A., 4 dia. on vacuum : Silencers - No silencer S GVASIL SPO GVASPO. 8
2 Options for micro-venturis, series GVA, S, B, D Option GVA V: (Option applicable for GVA, S, B and D, vacuum outlet M) This option allows a vacuum connector to be fitted on the suction cup system for connection to a monitoring vacuum switch (such as PSE ). This provides data on the vacuum level. Connection for 4 mm dia. tube swivelling Vacuum outlet, M female. H ø8. Quick-connect vacuum outlet for 4 mm dia. tube Option GVA C: (Factory fitted) Female connection /8 G (gas type) for collection of venturi exhaust. If a number of venturis are used, it is recommended to use a manifold, option GVAG... Exhaust manifold /8 gas. dia. Option GVASIL: Female connector /8 G. Silencer for GVA. dba noise level attenuation... dia. Option GVASPO: Silencer more efficient than GVASIL. dba noise level attenuation. Adjustment for adaptation to GVA7 or GVA9 models by screwing or unscrewing the white part.. ø. Option, vacuum filter GVA F8: (Fitting on GVA, S, B, D, vacuum outlet M) 4-micrometre filtration to avoid blocking of the venturi by dust. Note: These options are compatible with option GVAV. In this case, option GVAV must be fitted between GVA and option GVAF. /8 gas. dia. Filtering element 9.. Accessory GVAG (/4/6) Manifold: Compatible with GVA and GVAS (M or 4) Possibility of battery installation (manifold), 4 manifold models for,, 4 or 6 venturis simultaneously, exhaust manifold and a single compressed air supply. Material: anodized aluminium. Option GVAP, Manifold: Plug plate for blanking of unused venturi position. Option GVAGB Manifold: Plug, /4 gas type, blanking of compressed air or exhaust. Fitting of silencer on exhaust: Model SILGV Both "exhaust" outlets must be open for GVA G4 and GVA G6. Each of them is equipped with a silencer. ø4. ø7. Models GVA G GVA G GVA G4 GVA G6 L (mm) 7. 9 M (mm) L M ø4. ø7. /4 gas /4 gas
3 Curves for micro-venturis, series GVA, S, B, D 9 Negative pressure generated: GVA/S/B/D 9 GVA/S/B/D 7 Suction flow rate generated: GVA/S/B/D 9 GVA/S/B/D Air consumption: GVA/S/B/D 9 GVA/S/B/D 7 Flow rate / negative pressure curves: GVA/S/B/D 9 GVA/S/B/D Air consumption (Nl/min) The curves shown above indicate the mean values of the capacities of our products..
4 Controlled micro-venturis, series GVAS Venturi exhaust GVASIL can be fitted Reference V : Vacuum outlet Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia V P C.A. inlet, bars Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. Reference P : pressure 4.* x ø. * Dimension of GVASIL 8. Applications: The mini-venturis in series GVAS are of identical design to GVA venturis but also feature an integrated solenoid control. This additional feature reduces response times and allows easier fitting. Characteristics: Characteristics Nozzle Air Maximum Drawn-in At air ø consumption vacuum air pressure Models mm Nl/min % Nl/min bar GVAS 7 (blue).7 8 GVAS 9 (grey) Specifications: Compressed air Filtered, non-lubricated, pressure to 6 bars Temperature - to 8 C Material Polyacetal (POM) for venturi and base (black) Weight 8 g Control valve 4 V DC N.C. (4 V AC - V AC) Operating frequency Hz Fitting of optional equipment: GVAS micro-venturis can be fitted in manifolds (,, 4 or 6 units) to provide a common compressed air supply and exhaust collection. The vacuum connection option can be installed on venturis of type GVAS + M. See options on page. GVAS 4 : Nozzle diameter 7.7 mm (blue) 9.9 mm (grey) See curves GVA, S, B and D on page. : Connection M C.A. and vacuum M 4 C.A. and vacuum.7x4 M-4 C.A. M and vacuum.7x4 4-M C.A..7x4 and vacuum M : Control valve E 4 V DC N.C. E- Others on request 4: Silencers - No silencer S GVASIL SPO GVASPO. 9
5 Options for micro-venturis, series GVA, S, B, D Option GVA V: (Option applicable for GVA, S, B and D, vacuum outlet M) This option allows a vacuum connector to be fitted on the suction cup system for connection to a monitoring vacuum switch (such as PSE ). This provides data on the vacuum level. Connection for 4 mm dia. tube swivelling Vacuum outlet, M female. H ø8. Quick-connect vacuum outlet for 4 mm dia. tube Option GVA C: (Factory fitted) Female connection /8 G (gas type) for collection of venturi exhaust. If a number of venturis are used, it is recommended to use a manifold, option GVAG... Exhaust manifold /8 gas. dia. Option GVASIL: Female connector /8 G. Silencer for GVA. dba noise level attenuation... dia. Option GVASPO: Silencer more efficient than GVASIL. dba noise level attenuation. Adjustment for adaptation to GVA7 or GVA9 models by screwing or unscrewing the white part.. ø. Option, vacuum filter GVA F8: (Fitting on GVA, S, B, D, vacuum outlet M) 4-micrometre filtration to avoid blocking of the venturi by dust. Note: These options are compatible with option GVAV. In this case, option GVAV must be fitted between GVA and option GVAF. /8 gas. dia. Filtering element 9.. Accessory GVAG (/4/6) Manifold: Compatible with GVA and GVAS (M or 4) Possibility of battery installation (manifold), 4 manifold models for,, 4 or 6 venturis simultaneously, exhaust manifold and a single compressed air supply. Material: anodized aluminium. Option GVAP, Manifold: Plug plate for blanking of unused venturi position. Option GVAGB Manifold: Plug, /4 gas type, blanking of compressed air or exhaust. Fitting of silencer on exhaust: Model SILGV Both "exhaust" outlets must be open for GVA G4 and GVA G6. Each of them is equipped with a silencer. ø4. ø7. Models GVA G GVA G GVA G4 GVA G6 L (mm) 7. 9 M (mm) L M ø4. ø7. /4 gas /4 gas
6 Curves for micro-venturis, series GVA, S, B, D 9 Negative pressure generated: GVA/S/B/D 9 GVA/S/B/D 7 Suction flow rate generated: GVA/S/B/D 9 GVA/S/B/D Air consumption: GVA/S/B/D 9 GVA/S/B/D 7 Flow rate / negative pressure curves: GVA/S/B/D 9 GVA/S/B/D Air consumption (Nl/min) The curves shown above indicate the mean values of the capacities of our products..
7 Micro-venturis with blow-off control, series GVAB Reference V : Vacuum outlet Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. Venturi exhaust GVASIL can be fitted C.A. inlet, bars Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. Reference P : pressure 4.* x ø. * Dimension of GVASIL Applications: The mini-venturis in series GVAB feature an integrated solenoid control. This additional feature ensures quicker cycle time by controlled blowing and allows cleaning of the vacuum system in dusty environments. Micro-venturis in the GVAB series are either normally sucking (E to E) or normally blowing (E6). Diagram: normally blowing (E6) Characteristics: Characteristics Nozzle Air Maximum Drawn-in At air ø consumption vacuum air pressure Models mm Nl/min % Nl/min bar GVAB 7 (blue).7 8 GVAB 9 (grey) Specifications: Compressed air Filtered, non-lubricated, pressure to 6 bars Temperature - to 8 C Material Polyacetal (POM) for venturi and base (black) Weight 7 g Blow-off valve 4 V DC Operating frequency Hz Diagram: normally sucking (E to E) Blow-off principle: A piston controlled by the blow-off valve plugs the exhaust opening, so forcing the supplied compressed air to pass through the vacuum system (total blow-off). Fitting of optional equipment : Fitting of silencers GVASIL or GVASPO Connection for exhaust collection GVAC Vacuum filter GVA F8 For manifold fitting, consult our technical department. See options on page. GVAB 4 : Nozzle diameter 7.7 mm (blue) 9.9 mm (grey) See curves GVA, S, B and D on page. : Connection M M F, C.A. and vacuum 4.7/4 mm C.A. and vacuum M-4 M C.A..7/4 mm, vacuum 4-M C.A..7x4 and vacuum M : Blow-off valve E 4 V DC N.C. E6 Suction 4 V DC N.O. E- Others on request 4: Silencers - No silencer S GVASIL SPO GVASPO.
8 Options for micro-venturis, series GVA, S, B, D Option GVA V: (Option applicable for GVA, S, B and D, vacuum outlet M) This option allows a vacuum connector to be fitted on the suction cup system for connection to a monitoring vacuum switch (such as PSE ). This provides data on the vacuum level. Connection for 4 mm dia. tube swivelling Vacuum outlet, M female. H ø8. Quick-connect vacuum outlet for 4 mm dia. tube Option GVA C: (Factory fitted) Female connection /8 G (gas type) for collection of venturi exhaust. If a number of venturis are used, it is recommended to use a manifold, option GVAG... Exhaust manifold /8 gas. dia. Option GVASIL: Female connector /8 G. Silencer for GVA. dba noise level attenuation... dia. Option GVASPO: Silencer more efficient than GVASIL. dba noise level attenuation. Adjustment for adaptation to GVA7 or GVA9 models by screwing or unscrewing the white part.. ø. Option, vacuum filter GVA F8: (Fitting on GVA, S, B, D, vacuum outlet M) 4-micrometre filtration to avoid blocking of the venturi by dust. Note: These options are compatible with option GVAV. In this case, option GVAV must be fitted between GVA and option GVAF. /8 gas. dia. Filtering element 9.. Accessory GVAG (/4/6) Manifold: Compatible with GVA and GVAS (M or 4) Possibility of battery installation (manifold), 4 manifold models for,, 4 or 6 venturis simultaneously, exhaust manifold and a single compressed air supply. Material: anodized aluminium. Option GVAP, Manifold: Plug plate for blanking of unused venturi position. Option GVAGB Manifold: Plug, /4 gas type, blanking of compressed air or exhaust. Fitting of silencer on exhaust: Model SILGV Both "exhaust" outlets must be open for GVA G4 and GVA G6. Each of them is equipped with a silencer. ø4. ø7. Models GVA G GVA G GVA G4 GVA G6 L (mm) 7. 9 M (mm) L M ø4. ø7. /4 gas /4 gas
9 Curves for micro-venturis, series GVA, S, B, D 9 Negative pressure generated: GVA/S/B/D 9 GVA/S/B/D 7 Suction flow rate generated: GVA/S/B/D 9 GVA/S/B/D Air consumption: GVA/S/B/D 9 GVA/S/B/D 7 Flow rate / negative pressure curves: GVA/S/B/D 9 GVA/S/B/D Air consumption (Nl/min) The curves shown above indicate the mean values of the capacities of our products..
10 Micro-venturis with gripping & blow-off control, series GVAD Venturi exhaust GVASIL can be fitted Reference V : Vacuum outlet Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia C.A. inlet, bars Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. Reference P : pressure 4.* x ø. * Dimension of GVASIL Applications: The mini-venturis in series GVAD combine the advantages of series GVAS and GVAB: solenoid control as in series GVAS and blow-off control as in series GVAB while retaining very small dimensions and light weight.their compact design makes them easier to integrate into on-vehicle robotic systems. Both control valves must be supplied with air to perform the blow-off function. Characteristics: Characteristics Nozzle Air Maximum Drawn-in At air ø consumption vacuum air pressure Models mm Nl/min % Nl/min bar GVAD 7 (blue).7 8 GVAD 9 (grey) Specifications: Compressed air Filtered, non-lubricated, pressure to 6 bars Temperature - to 8 C Material Polyacetal (POM) for venturi and base (black) Weight g Control valve 4 V DC N.C. (4 V AC - V AC) Operating frequency Hz Fitting of optional equipment: Fitting of silencers GVASIL or GVASPO Connection for exhaust collection GVAC Vacuum filter GVA F8 For manifold fitting, consult our technical department. See options on page. GVAD 4 : Nozzle diameter 7.7 mm (blue) 9.9 mm (grey) See curves GVA, S, B and D on page. : Connection M C.A. and vacuum M 4 C.A. and vacuum.7/4 mm M-4 C.A. M and vacuum.7x4 4-M C.A..7x4 and vacuum M : Control valve E 4 V DC N.C. E- Others on request 4: Silencers - No silencer S GVASIL SPO GVASPO.
11 Options for micro-venturis, series GVA, S, B, D Option GVA V: (Option applicable for GVA, S, B and D, vacuum outlet M) This option allows a vacuum connector to be fitted on the suction cup system for connection to a monitoring vacuum switch (such as PSE ). This provides data on the vacuum level. Connection for 4 mm dia. tube swivelling Vacuum outlet, M female. H ø8. Quick-connect vacuum outlet for 4 mm dia. tube Option GVA C: (Factory fitted) Female connection /8 G (gas type) for collection of venturi exhaust. If a number of venturis are used, it is recommended to use a manifold, option GVAG... Exhaust manifold /8 gas. dia. Option GVASIL: Female connector /8 G. Silencer for GVA. dba noise level attenuation... dia. Option GVASPO: Silencer more efficient than GVASIL. dba noise level attenuation. Adjustment for adaptation to GVA7 or GVA9 models by screwing or unscrewing the white part.. ø. Option, vacuum filter GVA F8: (Fitting on GVA, S, B, D, vacuum outlet M) 4-micrometre filtration to avoid blocking of the venturi by dust. Note: These options are compatible with option GVAV. In this case, option GVAV must be fitted between GVA and option GVAF. /8 gas. dia. Filtering element 9.. Accessory GVAG (/4/6) Manifold: Compatible with GVA and GVAS (M or 4) Possibility of battery installation (manifold), 4 manifold models for,, 4 or 6 venturis simultaneously, exhaust manifold and a single compressed air supply. Material: anodized aluminium. Option GVAP, Manifold: Plug plate for blanking of unused venturi position. Option GVAGB Manifold: Plug, /4 gas type, blanking of compressed air or exhaust. Fitting of silencer on exhaust: Model SILGV Both "exhaust" outlets must be open for GVA G4 and GVA G6. Each of them is equipped with a silencer. ø4. ø7. Models GVA G GVA G GVA G4 GVA G6 L (mm) 7. 9 M (mm) L M ø4. ø7. /4 gas /4 gas
12 Curves for micro-venturis, series GVA, S, B, D 9 Negative pressure generated: GVA/S/B/D 9 GVA/S/B/D 7 Suction flow rate generated: GVA/S/B/D 9 GVA/S/B/D Air consumption: GVA/S/B/D 9 GVA/S/B/D 7 Flow rate / negative pressure curves: GVA/S/B/D 9 GVA/S/B/D Air consumption (Nl/min) The curves shown above indicate the mean values of the capacities of our products..
13 Modular ejector, series GVM The ejector in : Adjustable vacuum Adjustable blow-off Adjustable electronic vacuum switch Pressure output Exhaust collection Applications: A new concept in vacuum generation the GVM ejector range is based on the principle of modules which can be manifold mounted. It is aimed at the OEM market with the benefit of the maximum of functions in a small lightweight model. Each module of mm is very easy to install and offers: A vacuum generation by the ejector module. A threshold and vacuum adjustment by the vacuum switch module. An automatic blow-off by the capacity module. Compressed air source for subsidiary functions. Characteristics: Characteristics Nozzle Air Maximum Drawn-in air diam. consumption vacuum Nl/mn at 4 bars at 6 bars at 4 bars at 6 bars at 4 bars at 6 bars Models mm Nl/min in % Nl/min GVM, Ejector specification: Compressed air Filtrated, non lubricated, to 6 bars Temperature to 6 C Ejector material Polyacetal (POM) grey Capacity material Polyacetal (POM) black Vacuum switch material PA 6.6 % FG black Selector vacuum on/off Stop push and turn A a /4 turn clockwise Selector blow-off on/off Stop push and turn B a /4 turn clockwise Max. operating frequency Hertz Vacuum switch specification: Supply 8- V DC regulated, pole changing protection Current draw < ma Transistor output N.O. ma under 4 V DC PNP Thermal error ± % measuring scale from to C Output indicator LED Threshold adjustment Potentiometer /4 turn Operating temperature to + C (storage - to 6 C) Protection IP EMC Industrial standard, class B Locating on the automatic device: The slave nature of the ejector module in series GVM gives it a simple and reliable design and technology at a low price. Operating principle: From a pneumatic signal processed and controlled on the supply side, the ejector module GVM creates vacuum, blows and issues a pressure output. The integrated vacuum switch returns the information immediatly. -dimensional view of the ejector module: Specialist in vacuum handling
14 Manifold mounted ejector module, series GVM B- Applications: The GVM ejector module is very adaptable, it can be mounted in to 8 modules giving individual vacuum feeds from one or several pneumatic sources. Manifold mounting on the machine allows: an easy access to set up each ejector and to access the vacuum switch adjustment. pneumatic and electrical connections for a rational presentation of the unit. -dimensional manifold mounting principle of the ejector module: GVM : Number of ejector modules B Battery of ejector module B Battery of ejector modules B Battery of ejector modules B4 Battery of 4 ejector modules B Battery of ejector modules B6 Battery of 6 ejector modules B7 Battery of 7 ejector modules B8 Battery of 8 ejector modules : Exhaust manifold JC Set of manifolds >Suction cups Ejectors Vacuum switches Accessories
15 Coupling venturis, series VR C.A. inlet, /4 gas mm deep. Vacuum outlet M6 6 mm deep Example of suction cup VR M6 VR F8 VR F4 P V 7..8 M. Compressed air Exhaust. VR M8. P V P V C.A. inlet, /4 gas mm deep M 6. Vacuum outlet, /8 gas 7. mm deep C.A. inlet, /4 gas mm deep M P V P V C.A. inlet, /4 gas mm deep M 7. Vacuum outlet, /4 gas mm deep VR M4 C.A. inlet, /4 gas mm deep M /8 gas Hexagonal nut 4 across flats /4 gas Hexagonal nut 4 across flats Applications: The main advantage of the Coupling Venturi, series VR, is its direct fitting on the suction cup which allows simpler connection. By integrating the VR type venturi in the suction cup, we obtain a localized vacuum and, therefore, the possibility of obtaining multiple independent gripping, even when there are no materials detected. It is also possible to supply vacuum to two or more suction cups using a /8 Gas or /4 Gas tee fitting. Characteristics: Characteristics Nozzle Air Maximum Drawn-in At air ø consumption vacuum air pressure Models mm Nl/min % Nl/min bar VR VR VR Specifications: Compressed air Filtered, non-lubricated, pressure to 6 bars Temperature - to 8 C Material Anodized aluminium body, brass nozzle Weight g Fitting on spring system: Spring system, series TS, available strokes:,,, 7 mm, page 9. Anti-rotation spring system, series TSO, page 9. Ball joint systems, series IMU, page 9. Special designs: Possibility of special materials such as stainless steel and plastic, as per work specifications, and special characteristics such as suction flow rate or vacuum level. On request for model F8, provision of an auxiliary vacuum coupling M for connection of a vacuum switch. Curves and characteristics on page. VR : Nozzle diameter. mm 7.7 mm 9.9 mm : Vacuum outlet M6 M6, female M8 /8 gas, male M4 /4 gas, male F8 /8 gas, female F4 /4 gas, female. 4
16 Curves for coupling venturis, series VR Negative pressure generated: VR 9 VR 7 VR Suction flow rate generated: VR 9 VR 7 VR Air consumption (Nl/min) 4 4 Air consumption: VR 9 VR 7 VR Flow rate / negative pressure curves: VR 9 VR 7 VR The curves shown above indicate the mean values of the capacities of our products..
17 Mini-venturis, series GV GV C.A. C D N M I G A F K H 4. GV...VR M B B' Vacuum Vacuum E Adjusting screw on VR. max. Vacuum Models A B B C D E F G H I Vacuum K C.A. M N S K GV G/8 G /8 6-8, GV 6-4. G /4 G /4 4., Applications: The mini-venturis in series GV are light-weight and compact design. This two-fold advantage allows their integration in robotic systems. Version GV...VR is equipped with an electromagnetic vacuum switch so the user can control the vacuum level in the suction cup system at all times. Characteristics: Characteristics Nozzle Air Maximum Drawn-in At air ø consumption vacuum air pressure Models mm Nl/min Nl/min bar X N X N GV GV Specifications: Compressed air Filtered, non-lubricated, pressure to 6 bars Temperature - to 8 C Material Anodized aluminium Hysteresis (version VR) 4 to 4 mbars Weight GV GV GV/GV V/GV VR 8// 4/6/9 GV GV...VR Max. cutout capacity: V, Hz, A V, Hz, A Accessories: Compressed air control valve, COVAL reference: AP. See page 9. On request: Fitting of an electronic vacuum switch on models GV. Fitting of a vacuum switch, factory pre-adjusted to approx. - mbars, model V. Fitting of a non-clogging through silencer, issue K instead of S, for models. Fitting of a compressed air control solenoid valve. GV 4 : Nozzle diameter mm. mm : Vacuum level X 6% vacuum N 9% vacuum : Silencer - Without silencer S With diffuser type silencer K With through type silencer 4: Options - Without VR Adjustable vacuum switch (- to - mb) V Pre-adjusted vacuum switch (- mb approx.) Curves and characteristics on page 7.. 6
18 Curves for mini-venturis, series GV 9 8 Negative pressure generated: GV NS GV XS 8 6 Suction flow rate generated: GV XS GV NS GV XS 4 GV NS Air consumption (Nl/min) Air consumption: GV XS / NS GV XS / NS Flow rate / negative pressure curves 4 GV XS GV NS GV XS 4 GV NS The curves shown above indicate the mean values of the capacities of our products.. 7
Simple venturis, series GVP
Simple venturis, series GVP 5-bar compressed air network 45 13 5 35 L1 Exhaust D1 L 1/4 gas, 6x8 quick-connect or 4x6 quick-connect D 30 Connection for options 6 Vacuum 1/ gas Vacuum generators in series
More informationmini-modules compact integrated vacuum pumps LEM
mini-modules compact integrated pumps LEM TM www.coval.com LEM LEM series: mini-module pressure OUT IN 2 exhaust TM All industrial functions integrated into the mini-module Efficient communication for
More informationLEM. mini-modules compact integrated vacuum pumps. US3
mini-modules compact integrated pumps LEM TM www.coval.com US3 LEM LEM series: mini-module pressure OUT IN 2 exhaust TM certified quality management system All industrial functions integrated into the
More informationLEMAX. mini-modules. "ASC" compact vacuum pumps US2
mini-modules LEMAX "ASC" compact pumps TM www.coval.com US2 OUT IN pressure LEMAX series: compact P = 4 to 8 bar 3.5 bar blow-off exhaust 2 ➊ ➋ ➌ ➍ ➎ 3.5 bar pressure regulator "Vacuum" solenoid valve
More informationLEM. mini-modules compact integrated vacuum pumps. US5
mini-modules compact integrated pumps LEM TM www.coval.com US5 LEM LEM Series: Mini-Module pressure OUT IN 2 exhaust TM certified quality management system 40% energy savings (on average, see p.5). No
More informationMICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP
Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.
More informationMiniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer
Miniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer Fastbreak Mini Series: VP0X & VP0X-ADJ VP0X-60 Fastbreak blow-off pump with vacuum cup, spring leveler assembly for rapid part release
More informationVACUUM PUMP P5010. Profit from new vacuum technology
VACUUM PUMP P5010 COAX THE NEXT DIMENSION IN VACUUM TECHNOLOGY Profit from new vacuum technology Patented COAX push-in technology Efficient use of energy Outstanding performance Slim and modular design
More informationVacuum generators 1.1. High vacuum levels of up to 93% Easy connection of holders and suction cups. Lightweight and compact design.
High vacuum levels of up to 93% Easy connection of holders and suction cups Lightweight and compact design No wearing parts Long service life Vacuum monitoring with vacuum switch 2005/07 Subject to change
More informationMiniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off
Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off Fastvac Mini Series: VP01QR-60 VP01QR-60H/24vDC Standard
More informationVacuum Automation 2.1. The future depends on good product choices
Vacuum Automation 2.1 The future depends on good product choices Optimising controls 458 459 Optimising controls Introduction...460 Vacuum switches...462 Valves...478 Regulators...488 Automatic energy
More informationVacuum generation Compact ejectors
Energy saving function by integrated pressure control saves up to 5 % of energy q = Vacuum connection z = Compressed air connection Product notes s = Exhaust outlet Check valve with wire mesh to keep out
More informationWith Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-
Features and Benefits Solenoid-Actuated Vacuum Generators Types VADM-... / VADMI-... l Integral Filter, Silencer, Manual Override l Integral Solenoid Valve for Controlling Air Supply l Vacuum Range up
More informationMax Series Venturi Vacuum Pump with Pneumatic Blow-off and Silencer
Max Series Venturi Vacuum Pump with Pneumatic Blow-off and Silencer Fastbreak Max Series: VP8X & VP8X-ADJ VP8X-200 VP8X-200M-ADJ Standard Pump: VP8X & VP8X-ADJ air-powered venturi vacuum pumps are trusted
More informationFunction Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings
Flow Control Regulators Piloted Non-Return Valves LIQUIfit Pressure Fittings Other Silencers Flow Control Regulators (P. 4-6) Blocking Fittings (P. 4-36) Piloted Non-Return Valves (P. 4-38) Function:
More informationMULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle
More information[Small diaphragm vacuum pumps]
[Small diaphragm vacuum ] The small vacuum shown on this page produce vacuum using a diaphragm. They can be used either as vacuum pump or as a small compressor, and they are able to deliver 100% oil-free
More informationVacuum generators Key features
Vacuum generators Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The product families
More informationElectropneumatic pressure regulator EPP4 Series
Electropneumatic pressure regulator EPP4 Series Connection G ¼ Catalogue 8683/UK The ECONOMIC solution which meets the market requirements Compact design and lightweight for ease of installation and low
More informationMulti-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications
Multi-Stage Ejectors Suction rate from 332 l/min to 2,370 l/min Suitability for Industry-Specific Applications Applications Multi-stage ejector for handling of cardboard, packing materials, insulating
More informationVacuum pumps/generators Small
picompact10 Ejector with COAX patented technology. Reduced air-consumption with 30-50% compared to other ejector technologies. Easy to optimize vacuum performance with a varied selection of micro multi-stage
More informationMICRO CUP HOLDERS
MICRO CUP HOLDERS 0 80 05 - Extremely reduced size and weight - Stainless steel stem and spring - Self-lubricating bush built in the threaded sleeve ensuring a perfect sliding of the stem and durability
More informationSimple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.
SERIES LED Bar Display Mechanical Switch is Out of Date Choose the Contemporary Pressure Sensor with LED Bar Display Marked Conforming to EMC directive Bright LED Bar Display Easy to read the pressure
More informationMULTISTAGE MICRO EJECTORS
MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]
More informationDISTRIBUTORS. n o p q. hdm + multi-pole connection TECHNICAL DATA COMPONENTS
+ multi-pole connection HDMs are the ideal solution for those requiring the unbeatable performance, flexibility and modularity of Multimach valves combined with sturdy mechanics and a high degree of protection
More informationVacuum Generators. Catalogue Edition 2
Vacuum Generators Catalogue Edition 2 Switch Options S = SK = The fixed switch option is normally open and changes position at 12 Hg The adjustment of the SK model switch is between 6-16 Hg Features: Anodized
More informationSolenoid valves "ENOVA" Series 2300
Solenoid valves "ENOVA" Series 300.04 Series 300 Solenoid valves "ENOVA".05 Solenoid valves "ENOVA" Series 300 Solenoid - Differential (Monostable) 5/ 3eC.5.00.36.v ELECTRICAL CONTACTS 0=STANDARD-only
More informationSpecial valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.
Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx
More informationSolenoid valves "OPTYMA32-S" General. Series 2200
1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational
More informationSolenoid valves "OPTYMA32-S" General. Series 2200
1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational
More informationCAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power
CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators
More informationSECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS
SYSTEM ACCESSORIES SECTI 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS 6 2012 EDCO USA. www.edcousa.net 6:1 6 SYSTEM ACCESSORIES CTENTS VACUSTAT MECHANICAL PRESSURE SWITCH INLINE VACUUM FILTER
More informationMiniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure
Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing
More informationElectrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)
Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationPTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2
1-4009-EN PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2 The PTEX extruder pumps are pneumatically actuated pumps designed to deliver lubricant under pressure to lubrication
More informationElectrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)
Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to 1.001 Cv) Order code BM-02-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationTeSys GV2 - GV3 Manual Starters and Protectors
TeSys GV GV Manual Starters and Protectors A stronger, longterm connection Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA 94080670 General Inquiries: (800) 67048 www.stevenengineering.com
More informationCompact Proportional Solenoid Valve
Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.
More informationElectrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)
Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationSOLENOID VALVES AND PNEUMATIC VALVES
A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly
More informationnickel-plated brass - PBT technopolymer HNBR, FKM stainless steel
CATALOGUE > Release 8.8 > Series A solenoid valves Series A directly operated solenoid valves /-way - Normally Closed (NC) and Normally Open (NO) 3/-way - Normally Closed (NC) and Normally Open (NO)»»
More informationPneumatics CONTENT
Pneumatics CONTENT 2 3 4 5 6 7 8 9 Fittings 453 Flexible Tube 47 Quick Release Couplings 477 Actuators 485 Solenoid & Pneumatic Valves 495 Mechanical & Manual Valves 507 Automatic Valves 57 Filters, Regulators
More informationVacuum generators OVEM
Key features At a glance Accelerated vacuum reduction for safe placement of the workpiece by means of integrated solenoid valve for controlling the ejector pulse Central electrical connection via M12 plug
More informationMINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15
MINI-SOLENOID VALVES ISO 58 (CNOMO, size 5) interface direct operated, pad mounting body connector size 5 NC / Series 0 FEATURES Compact, monobloc solenoid pilot valve with spade-plug connector type EN
More informationVacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK
VACUUM VENTURI CV VACUUM VENTURI Anodized aluminum body All metal construction Maximum vacuum of 27 Hg Vacuum flow rates up to 8CFM Single stage technology HSK s include part presence switch R N CV 15
More informationVP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3.
Modular Venturi Vacuum Pumps Mid Series VP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3.2 VP1X Series Pneumatic Blow-Off
More informationMULTI JECTOR Vacuum Pumps
VOLKMANN MULTI JECTOR Vacuum Pumps and Vacuum Components by VOLKMANN multiple stage ejectors energy-saving compact ejectors stainless steel Vacuum Pumps vacuum switches vacuum filters VOLKMANN has been
More informationFunction Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. Pressure Fittings. Other Function Fittings.
Function Fittings Flow Control Regulators Piloted Function Fittings Non-Return Valves Pressure Fittings Other Function Fittings Silencers Function Fittings 4-3 Function Fittings Flow Control Regulators
More information14,5 PSC PSP PSR. INTEGRATED SUB-BASE MANIFOLD valve with no subbase
PS COMBOBOX Valves PSC Single electric connection INTEGRATED SUB-BASE MANIFOLD valve with no subbase REDUCED DIMENSIONS Space saving up to 0% in comparison with standard valve MANIFOLDS HIGH FLOW RATE
More informationBench Top Extraction Arms
Bench Top Extraction Arms The Nederman BenchTop arms can be used in every type of environment, ranging from assembly stations, where solder fumes are extracted, to laboratories, where protection against
More informationVACUUM PUMP Midi Keyboard Pump
Midi Keyboard Pump Max. vacuum level Max. flow rate Supply air pressure Supply air type : VKX pump -92 kpa (-27.16 inhg) VKM pump -85 kpa (-25.1 inhg) : VKX pump 62 Nl/min (2.19 scfm) VKM pump 74 Nl/min
More informationDIRECT OPERATED SOLENOID PILOT VALVES Product Index
DIRECT OPERATED SOLENOID PILOT VALVES Product Index ports/positions Function pipe connections * - instant fittings O.D. (mm) w - internal thread (ØG) x - external thread (ØG) n - pad mount : - pad mount,
More informationnickel-plated brass - PBT technopolymer HNBR, FKM stainless steel
CATALOGUE > Release 8.7 > Series A solenoid valves Series A directly operated solenoid valves /-way, 3/-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 - G1/8 - R1/8 - cartridge ø4
More informationAIR-T AIR-T AIR-T AIR-T
Exhaust Fan Units INDEX PAG. HIGH HEAD ASPIRATORS WITH SIDE GROOVE TURBINE KW m 3 /h mm H O 3 NC /70 TRAILER-MOUNTED WITH CYLINDER Ø 300, 35 000 3 NC 5/30 " " " " ",5 00 " 5 N 5/30A " " " " ",5 00 500
More informationCOILS, CONNECTORS, SOLENOID VALVES
COILS, CONNECTORS, SOLENOID VALVES 117 10 mm solenoids Solenoid valve 10 mm 00.441.0 Tension 24V DC ±10% Temperature range -5 C...+60 C (23 F... 140 F) Power 0.5... 1 W Operating pressure 0... 7 bar (0...
More informationSolenoid valves "OPTYMA32-S" General. Series 2200
1 General Series 2200 1 Series 2200 Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN Weight gr. 67 SHORT FUNCTION CODE "A" Serie Solenoid 2200-S-GB valves - Spring "OPTYMA32-S"
More informationBM-01. Electrically operated valves 3/2-way G 1/8, Nl/min ( Cv) Technical data for series. Order code BM HNR-162
Electrically operated valves 3/2-way G 1/8, 600 660 Nl/min (0.610 0.671 Cv) Technical data for series BM-01 Order code BM-01-310-HNR-162 Series and function BM = Standard Manual override HNT = non-detented
More informationJUMO MIDAS Pressure transmitter
Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids
More informationSquare Mixed Flow Fans (MFQ)
Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are
More informationFuel Oil Deaerator with Integrated Filter Type GS 2000
Edition 11.02 Page 1 Fuel Oil Deaerator with Integrated Filter Type GS 2000 Fuel oil deaerator to DIN EN 12514-2 with filter and quick action stop valve General Design Operating materials Connections Designation
More informationBM-02. Electrically operated valves 3/2-way G 1/4, Nl/min ( Cv) Technical data for series. Order code BM HNR-162
Electrically operated valves 3/2-way G 1/4, 920 1090 Nl/min (0.935 1.001 Cv) Technical data for series BM-02 Order code BM-02-310-HNR-162 Series and function BM = Standard Manual override HNT = non-detented
More informationServotronic Digital 615 Series
Servotronic Digital 615 Series Proportional Technology www.asco.com PRESSURE CONTROL: 615 SERIES SERVOTRONIC Digital Servotronic Digital Greater versatility in automated production processes: Due to electronics,
More informationZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector
Pressure Switch Model Selection Table Self-contained Type ZSE20(F) ZSE30A(F) ISE30A ZSE40A(F) ISE40A ZSE10(F) Model Fluid Calibration method Set pressure range Power supply voltage 105 to 105 kpa 10 to
More informationKeystone F89 pneumatic quarter-turn actuator General purpose / hazardous area
Compact, reliable and low operation costs for all types of quarter-turn valves are the keywords of the Keystone F89 range of pneumatic actuators Features Direct mounting to all Keystone butterfly valves
More informationKEYSTONE F89 pneumatic quarter-turn actuator GENERAL PURPOSE / HAZARDOUS AREA
compact, reliable and low operation costs for all types of quarter-turn valves are the keywords of the Keystone F89 range of pneumatic actuators FEATURES Direct mounting to all Keystone butterfly valves
More informationSentronic LP IO-Link CLASS A 617 Series. Proportional Technology
Sentronic LP IO-Link CLASS A 617 Series Proportional Technology PROPORTIONAL PRESSURE CONTROL: 617 SERIES SENTRONIC LP IO-LINK VERSION ASCO NUMATICS Sentronic LP The Sentronic LP is a highly efficient
More informationSERIES PRE PROPORTIONAL PRESSURE REGULATOR WITH COILVISION TECHNOLOGY
SERIES PRE PROPORTIONAL PRESSURE REGULATOR WITH COILVISION TECHNOLOGY 4.0 READY SERIES PRE PRESSURE UNDER CONTROL WITH DIAGNOSIS THROUGH THE CLOUD NFC WIRELESS MICRO USB The Series PRE proportional pressure
More informationCPLab / CP Factory. Application module magazine. Data sheets
CPLab / CP Factory Application module magazine Data sheets Data sheet: Push-in fitting QSM-M5-4 #153304 Size Mini Nominal size 2.2 mm Type of seal on screw-in stud Sealing ring Container size 10 Design
More informationSBM TECHNOLOGY PET Blow Valve Block
Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)
More informationElectropneumatic pressure regulator EPP4 Series. Connection G ½. Catalogue 8684/UK G ½"
Electropneumatic pressure regulator EPP4 Series Connection G ½ Catalogue 8684/UK G ½" The ECONOMIC solution which meets the market requirements Compact design and lightweight for ease of installation and
More informationStandard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure
Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety
More informationPUMA RANGE OF AIR TOOLS
Type G / ATAT-3170 3mm Micro Pencil Grinder PUMA RANGE OF AIR TOOLS Now with new Safety levers. Better quality & Lower prices! ATAT-7032 6mm Mini Die Grinder ATAT-7033 6mm Straight Die Grinder ATAT-7033L
More informationMICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm
MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D..65 to 9.5 mm U / Series 84 FEATURES Solenoid valve suitable for cutting off the flow of a fluid by pinch For sterile, aseptic, physiological
More informationC 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 G1/4 8,5
CL/CM UNIVERSAL Valves G1/8 - CHARACTERISTICS Ambient temperature Fluid Commutation system Pressure Max Connections Nominal bore (mm) Nominal flow rate (Nl/min) Valve body Seals Spool Electropilot/Coil
More informationVMECA Vacuum Auto - Locking system
VMECA Vacuum Auto - Locking system www.vmeca.com Vacuum Auto Locking system Introduction In the automobile industries today, vacuum is widely used for a pick and place applications on automobile parts
More informationMicro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES
MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...
More informationElectrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)
Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =
More informationGENERAL PUMPA member of the Interpump Group
FEATURES Innovative drive design eliminates need for auxiliary hydraulic drive HWB Series Hydraulic Drive - Triplex Plunger Pump HWB2512 & HWB2112 Forged brass manifold No scheduled maintenance required
More informationCode Desc /8. Tecnical Features. Inlet diameter with reductions 1/2-3/8
Filter - regulator - lubricator Three in one tool which combines in a single body for the air filter, regulator and lubricator outlet pressure in line for pneumatic tools. Necessary where there is any
More informationSimultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board
With an innovative concept and a pioneering approach to valve design, Mead s new technology has directly challenged the conventions of traditional valve manufacturers. In doing so, Mead has overcome many
More informationSeries RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C
Technical details Temperature range Medium -0 C... +50 C Filtered, oil-free and dried compressed air according to ISO 857-:00, Class 7::, instrument air, free of aggressive additives. Alternatively the
More informationRelated vacuum products
Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter
More informationData Sheet. I/P and E/P converters. RS stock numbers ,
Data Pack G Issued March 997 3-4998 Data Sheet I/P and E/P converters RS stock numbers 79-47, 79-48 Standard (electro-mechanical) Construction Housing Zinc diecastings, passivated and black epoxy paint,
More informationMiniature Regulator Series ARJ310
Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates
More information3D drawings available at Kg GAS-NPT thread adapters available at page 1.117
These small dry vacuum pumps have a suction capacity of 2 and 4 cum/h. The particular shape of the working chamber and the special graphite, with which the locking flanges and vanes are made, allow these
More informationVacuum Generators. Section B.
Section www.parker.com/pneu/vacgen 2 asic Generator Selection How to Select a Generator 4-9 Inline : Single Stage MCA, CV, CV-CK MCA is lightweight generator that can be located directly on the cup fitting
More information22C, 22CX, 22CX5, 26LC Series
C, CX, CX, LC Series ON/OFF electrothermic actuators Technical Data Sheet WattsWater.eu Description The electrothermic actuators C, CX, CX and LC Series are ON/OFF devices used for automatic actuation
More informationCylindrical Pumps. J-Series Cylindrical Venturi Pumps
J-Series Cylindrical Venturi Pumps The J-Series Venturi Vacuum Pumps utilize a fixed cartridge venturi design. J-Series pumps employ a cylindrical design for ease of installation and mounting into in-line
More information15 Flow Meter SCQ. Measurement principle: spring/piston system
15 Flow Meter SCQ Measurement principle: spring/piston system Flow measurement with direction indication Response time < 2 ms Compact design Withstands pressures up to 420 bar Wide range of viscosity p/t/q
More informationVacuum Components SHREE VYANKATESHWARA E N T E R P R I S E S
CKD Actuators Pneumatic Valves Pneumatic Auxiliary Components Pneumatic Auxiliary Components (Main Line Unit) Pneumatic Filter, Regulator, Lubricator (F.R.L. Unit) Related Pneumatic Products DD Actuator
More informationMicro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES
MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...
More informationSOLENOID VALVES AND PNEUMATIC VALVES
S E R I E S P Directly operated mini-solenoid valves Series P 3/ way N.C. or N.O. Ports M5 (for single base) Cartridge ø 3 and 4 (for manifold) Note: All the serie P electrovalves are basic in DC. For
More informationMICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.
ME12, ME25, ME60 Specifications Micro ejectors Media Operating pressure range MPa [psi.] Operating temperature range C [ F] Nozzle diameter Note mm [in.] kpa [in.hg] flow rate Note R/min [ft. 3 /min.]
More informationCatalogue Commercial vacuum cleaners Scrubber/dryers Single discs
Catalogue 2012 Commercial vacuum cleaners Scrubber/dryers Single discs WHY VIPER VIPER provides cleaning machines for professional use. Our products offers you the following features and benefits: - Ease
More informationBalanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves
Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves www.humphrey-products.com Humphrey Products Company P.O. Box 008 Kalamazoo, MI 4900 USA P.69.8.5500 F.69.8.4 BVSa-07 A privately owned
More informationPaddle-wheel flow controller with optical principle for On/Off control
Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor
More informationSERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits
SERIES LED Display Digital Pressure Sensor PE DP-M DP-Y DP3 High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response time at a high resolution of 1/1,000. It enables highly accurate
More informationPSP PSP PSC PSR TECHNICAL CHARACTERISTICS. ComboBox series. Valves. Flow rates according to fittings:
ComboBox series The new ComboBox valves are the result of long reflections regarding the requirements of the modern user, the current market demands, the ever increasing needs in the ergonomical and ecological
More informationpneumatic function fittings
Parker Legris connectic products are available from MARYLAND METRIS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 email: sales@mdmetric.com web:
More information