Simple venturis, series GVP
|
|
- Clara Dawson
- 5 years ago
- Views:
Transcription
1 Simple venturis, series GVP 5-bar compressed air network L1 Exhaust D1 L 1/4 gas, 6x8 quick-connect or 4x6 quick-connect D 30 Connection for options 6 Vacuum 1/ gas Vacuum generators in series GVP are the basic venturis in the modular range. Recommended for applications without control, they are available at 5 different power levels (evacuation time) and 3 different vacuum levels: version X with 50% vacuum for very porous products, version T with 75% for porous products and version N with 90% vacuum for sealed products. The suction flow rate increases as the maximum vacuum level decreases, with the same nozzle diameter. As well as being used with suction cups, they can be used for the purposes of liquid metering, spraying and tank depressurization, etc Tube 4x6 connection ø consumption as % Nl/min mm Gas mm mm Models mm Nl/mn X T N X T N X N/T X N/T X N/T S K(N/T) K(X) GVP / 1/ GVP / 1/ GVP / 1/ GVP / 1/ GVP / 1/ On standard basis, versions N and T are supplied with silencer S and version X is supplied with silencer K, except for model GVP 30 which is always equipped with silencer K. Temperature -10 to 80 C Optimal pressure Body material DELRIN GVP mm 5.5 mm 30 3 mm X 50% vacuum 14 1/4 G BSPP 46 tube 4/6 calibrated 68 tube 6/8 calibrated Note: Versions N and T: silencer S and K Version X: silencer K 01.0
2 V A C U U M H A N D L I N G Selecting a venturi Evacuation time in seconds for 1 litre: % VACUUM GV 05 N VR GVA VR GVA VR GV 10 N GVP 1 N GV 15 N GVP 15 N GV 0 N GVP 0 N GVP 5 N GVP 30 N % VACUUM GVP 1 T GVP 15 T GVP 0 T GVP 5 T GVP 30 T % VACUUM GV 05 X GV 10 X GVP 1 X GV 15 X GVP 15 X GV 0 X GVP 0 X GVP 5 X GVP 30 X Weight of venturis in grams: MODELS GVP GVPS GVPD GVC GVCS GVS OPTIONS GVO PSE100 E Electrical output vacuum switch g GVO PSE100 EC Electrical output vacuum switch with connector g GVO PSL100 PNP Electronic vacuum switch g GVO PSA100 PNP Display type electronic vacuum switch g GVO VAF11140 Vacuum gauge VAF g CONTROLLERS Pneumatic controller g Electric controller g
3 Venturis with automatic blow-off, series GVC H6 5-bar compressed air network Connection for options 13 8, 35 Blowing flow restrictor 49. Vacuum 1/ gas L Plug, 1/8 gas, for boosted blowing 1/4 gas, 6x8 quick-connect Exhaust or 4x6 quick-connect L Vacuum generators in series GVC are venturis with automatic blow-off. This special feature allows the part gripped to be released automatically, so speeding up work rates and simplifying the wiring of the venturi. For control of vacuum generation, see the GVCS range. The addition of a 1/8 gas type male connection on the unit allows the fitting of a supplementary compressed air tank to increase the blowing capacity, e.g. for large-diameter suction cups. D1 D Tube 4x6 Compressed air connection 1 ø consumption as % Nl/min mm Gas mm mm Models mm Nl/min T N T N N/T N/T N/T S K GVC / GVC / On standard basis, supplied with silencer S. Temperature 0 to 60 C Unit material DELRIN 500, grey and blue Optimal pressure Blowing flow rate Adjustable by flow restrictor Body material DELRIN Hz Blowing adjustment on bottom for manifold installation. Provision of a 1/8 gas type port on front for connection of a vacuum gauge. Specific features (on request): The auto blow-off function is also available with more powerful vacuum generators ( and.5 mm nozzles). GVC BSPP 46 tube 4x6 calibrated Note: Versions N and T: silencer S
4 V A C U U M H A N D L I N G Selecting a venturi Evacuation time in seconds for 1 litre: % VACUUM GV 05 N VR GVA VR GVA VR GV 10 N GVP 1 N GV 15 N GVP 15 N GV 0 N GVP 0 N GVP 5 N GVP 30 N % VACUUM GVP 1 T GVP 15 T GVP 0 T GVP 5 T GVP 30 T % VACUUM GV 05 X GV 10 X GVP 1 X GV 15 X GVP 15 X GV 0 X GVP 0 X GVP 5 X GVP 30 X Weight of venturis in grams: MODELS GVP GVPS GVPD GVC GVCS GVS OPTIONS GVO PSE100 E Electrical output vacuum switch g GVO PSE100 EC Electrical output vacuum switch with connector g GVO PSL100 PNP Electronic vacuum switch g GVO PSA100 PNP Display type electronic vacuum switch g GVO VAF11140 Vacuum gauge VAF g CONTROLLERS Pneumatic controller g Electric controller g 0.00
5 Controlled venturis, series GVPS Ø Manual control 5-bar compressed air network 5 35 Electric control Exhaust D1 L D H13 1/4 gas or 6x8 quick-connect Connection for options 4 6 Vacuum 1/ gas Vacuum generators in series GVPS control vacuum generation by means of an integrated valve. This installation simplifies wiring and reduces venturi response times. The valve can be controlled electrically (all voltages) or pneumatically (control by pneumatic logic and for explosion-proof conditions). L Tube 6/8 ø consumption as % Nl/min mm Gas mm mm Models mm Nl/min X T N X T N X N/T X N/T X N/T S K(N/T) K(X) GVPS / 1/ GVPS / 1/ GVPS / 1/ GVPS / 1/ GVPS / 1/ On standard basis, versions N and T are supplied with silencer S and version X is supplied with silencer K, except for model GVPS 30 which is always equipped with silencer K. Temperature 0 to 60 C Optimum pressure Max. valve flow rate 750 Nl/min at 5 bar N of valve operations 15 million Hz maximum Function N.C. Function N.O. at 4 V DC on request Valve / Body material DELRIN 100 GVPS mm 5.5 mm 30 3 mm X 50% vacuum /4 G BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V - 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 Note: Versions N and T: silencer S and K Version X: silencer K
6 V A C U U M H A N D L I N G Selecting a venturi Evacuation time in seconds for 1 litre: % VACUUM GV 05 N VR GVA VR GVA VR GV 10 N GVP 1 N GV 15 N GVP 15 N GV 0 N GVP 0 N GVP 5 N GVP 30 N % VACUUM GVP 1 T GVP 15 T GVP 0 T GVP 5 T GVP 30 T % VACUUM GV 05 X GV 10 X GVP 1 X GV 15 X GVP 15 X GV 0 X GVP 0 X GVP 5 X GVP 30 X Weight of venturis in grams: MODELS GVP GVPS GVPD GVC GVCS GVS OPTIONS GVO PSE100 E Electrical output vacuum switch g GVO PSE100 EC Electrical output vacuum switch with connector g GVO PSL100 PNP Electronic vacuum switch g GVO PSA100 PNP Display type electronic vacuum switch g GVO VAF11140 Vacuum gauge VAF g CONTROLLERS Pneumatic controller g Electric controller g
7 Controlled venturis with automatic blow-off, series GVCS Vacuum generators in series GVCS are of identical design to series GVC. Their special feature is vacuum generation control by means of an integrated valve. The valve control function speeds up response times and makes wiring easier by integrating all functions. For longer blow-off, see the GVPD range. The addition of a 1/8 gas type coupling on the unit allows the connection of a supplementary compressed air tank to increase the blowing capacity, e.g. for large-diameter suction cups. ø consumption as % Nl/mn mm Gas mm mm Models mm Nl/min T N T N N/T N/T N/T S K GVCS / GVCS / On standard basis, supplied with silencer S. Temperature 0 to 60 C Capacity material DELRIN 500, grey and blue Optimum pressure Blowing flow rate Adjustable by flow restrictor. N of valve operations 15 million Hz maximum Function N.C. Function N.O. at 4 V DC on request Valve / body material DELRIN 100 Possibility of increasing capacity volume. GVCS 1 Note: Versions N and T: silencer S and K Version X: silencer K BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V- 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 v 03 5
8 Venturis with gripping & blow-off control, series GVPD Vacuum generators in series GVPD control vacuum generation and blowing (with adjustable flow rate). The control of blowing, in terms of power and time, speeds up gripping/releasing rates, allows parts to be cleaned before gripping, and improves release for large diameter suction cups. ø consumption as % Nl/min mm Gas mm mm Models mm Nl/min X T N X T N X N/T X N/T X N/T S K(N/T) K(X) GVPD / 1/ GVPD / 1/ GVPD / 1/ GVPD / 1/ GVPD / 1/ On standard basis, versions N and T are supplied with silencer S and version X is supplied with silencer K, except for model GVP 30 which is always equipped with silencer K. N of valve operations 15 million Hz maximum Valve function N.C. Valve function N.O. at 4 V DC on request Valve/body material DELRIN 100 Optimal pressure Blowing flow rate 30 Nl/min closed, 60 Nl/min open GVPD mm 5.5 mm 30 3 mm X 50% vacuum Note: Versions N and T: silencer S and K Version X: silencer K /4 G BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V - 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 v 03 6
9 Safety venturis with blow-off, series GVS The vacuum generator in the GVS series is more commonly known as a safety venturi. Like those in the GVPD range, it has integrated vacuum generation and blowing. In addition, two safety non-return valves hermetically blank off the vacuum circuit in the event of failure of either of the two power sources (electric and/or pneumatic). It therefore ensures that parts remain gripped. Caution: Parts to be handled must be of the non-porous type. Characteristics Nozzle Air Max. Drawn-in air D D1 L1* L ø consumption vacuum Models mm Nl/min as % Nl/min mm Gas mm mm N S K GVS / GVS / GVS / GVS / GVS / (*): L1 equipped with standard silencer N of valve operations 15 million Hz maximum Valve function N.C. Valve function N.O. at 4 V DC on request Valve/body material Aluminium Optimal pressure Work rate Less than 0 cycles per minute GVS mm 5.5 mm 30 3 mm /4 G BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V - 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 v 03 7
Micro-venturis, series GVA
Micro-venturis, series GVA Reference V : vacuum outlet Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. or Male coupling, 4 mm dia.,. mm long ø. 4... Version GVA -- 44 GVASIL or GVASPO
More informationMulti-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications
Multi-Stage Ejectors Suction rate from 332 l/min to 2,370 l/min Suitability for Industry-Specific Applications Applications Multi-stage ejector for handling of cardboard, packing materials, insulating
More informationLEM. mini-modules compact integrated vacuum pumps. US3
mini-modules compact integrated pumps LEM TM www.coval.com US3 LEM LEM series: mini-module pressure OUT IN 2 exhaust TM certified quality management system All industrial functions integrated into the
More informationmini-modules compact integrated vacuum pumps LEM
mini-modules compact integrated pumps LEM TM www.coval.com LEM LEM series: mini-module pressure OUT IN 2 exhaust TM All industrial functions integrated into the mini-module Efficient communication for
More informationVacuum generation Compact ejectors
Energy saving function by integrated pressure control saves up to 5 % of energy q = Vacuum connection z = Compressed air connection Product notes s = Exhaust outlet Check valve with wire mesh to keep out
More informationLEM. mini-modules compact integrated vacuum pumps. US5
mini-modules compact integrated pumps LEM TM www.coval.com US5 LEM LEM Series: Mini-Module pressure OUT IN 2 exhaust TM certified quality management system 40% energy savings (on average, see p.5). No
More informationVACUUM PUMP Midi Keyboard Pump
Midi Keyboard Pump Max. vacuum level Max. flow rate Supply air pressure Supply air type : VKX pump -92 kpa (-27.16 inhg) VKM pump -85 kpa (-25.1 inhg) : VKX pump 62 Nl/min (2.19 scfm) VKM pump 74 Nl/min
More informationLEMAX. mini-modules. "ASC" compact vacuum pumps US2
mini-modules LEMAX "ASC" compact pumps TM www.coval.com US2 OUT IN pressure LEMAX series: compact P = 4 to 8 bar 3.5 bar blow-off exhaust 2 ➊ ➋ ➌ ➍ ➎ 3.5 bar pressure regulator "Vacuum" solenoid valve
More informationVacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK
VACUUM VENTURI CV VACUUM VENTURI Anodized aluminum body All metal construction Maximum vacuum of 27 Hg Vacuum flow rates up to 8CFM Single stage technology HSK s include part presence switch R N CV 15
More informationVacuum Generators. Catalogue Edition 2
Vacuum Generators Catalogue Edition 2 Switch Options S = SK = The fixed switch option is normally open and changes position at 12 Hg The adjustment of the SK model switch is between 6-16 Hg Features: Anodized
More informationEjector, Series EBS push-in fitting electrical control, T-design with release valve with silencer
Type Ejector Ambient temperature min./max. + C / + C Medium temperature min./max. + C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed
More informationGeneral characteristics Operating fluid Compressed air or inert gas Conditions of use Operating pressure 30 to 20 PSI (2 to 8 bars). Fluid: Filtered a
Pneumatic Logic Components Order/Technical Support Tel: (800) 67753 / FAX: (800) 6773865 / www.crouzetusa.com 5/3 5 General characteristics Operating fluid Compressed air or inert gas Conditions of use
More informationMulti-Stage Air Powered Vacuum Pumps
Multi-Stage Powered Pumps The MSP Series Multi-Stage Pneumatically-Driven Pumps operate on the Venturi Principle. These pumps are designed for applications requiring high flows at moderate vacuum levels.
More informationFunction Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings
Flow Control Regulators Piloted Non-Return Valves LIQUIfit Pressure Fittings Other Silencers Flow Control Regulators (P. 4-6) Blocking Fittings (P. 4-36) Piloted Non-Return Valves (P. 4-38) Function:
More informationChain lubrication unit WS-E
Product description Chain lubrication unit WS-E APPLICATION The central lubrication system WS- E is used for automatic and metered lubrication of chains, joints, rollers, hinges, etc. This system is also
More informationCOILS, CONNECTORS, SOLENOID VALVES
COILS, CONNECTORS, SOLENOID VALVES 117 10 mm solenoids Solenoid valve 10 mm 00.441.0 Tension 24V DC ±10% Temperature range -5 C...+60 C (23 F... 140 F) Power 0.5... 1 W Operating pressure 0... 7 bar (0...
More informationEjector, Series EBS Thread connection pneumatic control, T-design with silencer
Type Ejector Ambient temperature min./max. +0 C / + C Medium temperature min./max. +0 C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed
More information5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm
> Series E valves and solenoid valves Series E valves and solenoid valves 5/-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm Series
More informationVacuum technology Moduflex vacuum generator Peripheral module
Vacuum technology Moduflex generator Peripheral module Catalogue PDE2548SLUK-ev Moduflex generator Summary Page Applications... 3 Vacuum technology... 4 Order codes...5 Complete generators and stand alone
More informationVACUUM CUP SUPPORTS. 3D drawings available at
In the following pages are listed the cups for which each support is suited. They are specially shaped to perfectly adhere to the internal profile of the cups and they are provided with a male or female
More informationSolenoid valves "ENOVA" Series 2300
Solenoid valves "ENOVA" Series 300.04 Series 300 Solenoid valves "ENOVA".05 Solenoid valves "ENOVA" Series 300 Solenoid - Differential (Monostable) 5/ 3eC.5.00.36.v ELECTRICAL CONTACTS 0=STANDARD-only
More informationValves and Solenoid valves Series E 2/
CATALOGUE > Release 8.6 > Series E valves and solenoid valves Valves and Solenoid valves Series E 5/-way monostable/bistable - 5/3 CC CO CP With outlets on the body - For individual or manifold assembly
More informationSolenoid valves "OPTYMA32-S" General. Series 2200
1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational
More informationSolenoid valves "OPTYMA32-S" General. Series 2200
1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational
More informationPTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2
1-4009-EN PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2 The PTEX extruder pumps are pneumatically actuated pumps designed to deliver lubricant under pressure to lubrication
More informationPSP PSP PSC PSR TECHNICAL CHARACTERISTICS. ComboBox series. Valves. Flow rates according to fittings:
ComboBox series The new ComboBox valves are the result of long reflections regarding the requirements of the modern user, the current market demands, the ever increasing needs in the ergonomical and ecological
More informationSolenoid valves "OPTYMA32-S" General. Series 2200
1 General Series 2200 1 Series 2200 Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN Weight gr. 67 SHORT FUNCTION CODE "A" Serie Solenoid 2200-S-GB valves - Spring "OPTYMA32-S"
More informationREVERSIBLE HYDRAULIC POWER PACKS. 1 node/142/
REVERSIBLE HYDRAULIC POWER PACKS 1 node/142/ 2 Introduction Oil Sistem is a leader in power packs production and offers a wide range of solutions suitable for every type of application. Oil Sistem developed
More information1 01 / 201 Edition ED. 01/2007
Edition 01 / 2011 ED. 01/2007 TABLE OF CONTENENTS 1 INTRODUCTION 2 GRIPPER EXAMPLES 2.1 EXAMPLE A: GRIPPER WITH TUBES AND ALUMINIUM PROFILES 2.2 EXAMPLE B: GRIPPER WITH STAINLESS STEEL TUBES 2.3 EXAMPLE
More informationCatalog 080-/USA Notes Vacuum Control Valves
Vacuum Control Valves Section Catalog 080-/USA Notes Vacuum Control Valves Catalog 080-/USA Index Vacuum Control Valves VA0 Vacuum Control Valves for Centralized Vacuum Systems VA0PSV & VA0PSP, -Port,
More informationZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector
Pressure Switch Model Selection Table Self-contained Type ZSE20(F) ZSE30A(F) ISE30A ZSE40A(F) ISE40A ZSE10(F) Model Fluid Calibration method Set pressure range Power supply voltage 105 to 105 kpa 10 to
More informationValve Islands Series F
CATALOGUE > s 01 Valve Islands Series F > Valve Island Series F Multipole integrated electrical connection (PNP) Valve functions: x/; x3/; 5/; 5/3 CC The use of technopolymer in this Series has allowed
More informationVacuum Components SHREE VYANKATESHWARA E N T E R P R I S E S
CKD Actuators Pneumatic Valves Pneumatic Auxiliary Components Pneumatic Auxiliary Components (Main Line Unit) Pneumatic Filter, Regulator, Lubricator (F.R.L. Unit) Related Pneumatic Products DD Actuator
More informationVACUUM PUMP P5010. Profit from new vacuum technology
VACUUM PUMP P5010 COAX THE NEXT DIMENSION IN VACUUM TECHNOLOGY Profit from new vacuum technology Patented COAX push-in technology Efficient use of energy Outstanding performance Slim and modular design
More informationWith Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-
Features and Benefits Solenoid-Actuated Vacuum Generators Types VADM-... / VADMI-... l Integral Filter, Silencer, Manual Override l Integral Solenoid Valve for Controlling Air Supply l Vacuum Range up
More informationSECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS
SYSTEM ACCESSORIES SECTI 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS 6 2012 EDCO USA. www.edcousa.net 6:1 6 SYSTEM ACCESSORIES CTENTS VACUSTAT MECHANICAL PRESSURE SWITCH INLINE VACUUM FILTER
More informationSPRAY GUN ACCESSORIES & ANCILLARY EQUIPMENT
SPRAY GUN ACCESSORIES & ANCILLARY EQUIPMENT A15 - Accessory Kit 5 piece air tool kit, consisting of the most popular items Lightness, balance and manufactured to the highest quality Designed to use with
More informationSECTION 7 AX SERIES PUMPS
SECTION X SERIES PUMPS EDCO US www.edcousa.net : X PUMPS Z - ZERO BSE G /8 NPSF G / NPSF LRGE CPCITY G / NPSF General Information : Z: Zero Base (No Base) :4 G/8 NPSF Bases :5 - :6 G/ NPSF Bases : - :
More informationPI 1 Plug-in Injector
Operating Instructions and Spare Parts List PI 1 Plug-in Injector PI 1 1 12 PI 1 Table of contents PI 1 Plug-in injector for organic powders................................... 1 Fields of application....................................................
More informationSeries ISA. Air Catch Sensor. For Detection of Work Presence
ED Bar graph for easy calibration The ED bar graph indicator in conjunction with the adjustment knob for the variable orifice allows for easy and correct calibrations. Over range (Red) Correct range (Green)
More informationFunction Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. Pressure Fittings. Other Function Fittings.
Function Fittings Flow Control Regulators Piloted Function Fittings Non-Return Valves Pressure Fittings Other Function Fittings Silencers Function Fittings 4-3 Function Fittings Flow Control Regulators
More informationAIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block
INSTRUCTION MANUAL AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block Manual : 0306 573.002.212 Date : 12/06/03 Supersedes : 17/06/02 Modif. 1 + 4 added KREMLIN REXSON Site de Stains : 150,
More informationL170R01 SF 6. For liquid storage. gas service cart. 10" touch panel. Technical data: Dimensions: L mm, W mm, H mm Weight: 890 kg
For liquid storage L170R01 10" touch panel Technical data: Dimensions: L 2.250, W 1.050, H 1.220 Weight: 890 kg C 2980-06 Service carts L170R.. / L280R.. / L550R.. Mega Series For liquid storage L280R..
More informationLockable isolation 3/2-way valves Series MX 3/
CATALOGUE > Release 8.5 > /2-way isolation valves Series MX Lockable isolation /2-way valves Series MX New MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Modular Manual, electro-pneumatic, servo-pilot and
More informationLine-Mounted Valves L Series. L1 / L2 Series Overview L22 BA4 52. Valve Function. Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* =
How to order: (example) Line-Mounted L Series L1 / L2 Series Overview L22 BA4 52 Function Function Mounting BA4 = BB4 = PP6 = PP7 = 52 = Line mounted 00* = Manifold mounted w/o Adapter * L11 / L12 series
More informationAir Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics
ir Service Units Filter pressure regulator + Lubricator - Size Series 00 Construction and working characteristics - Zinc alloy body or reinforced technopolymer body with threaded brass insert connections.
More informationSYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8
Port Air Operated Valve SYA000/000/7000 How to Order Symbol M C6 01F C6 02F C10 Without bracket A/B port size Port size Series M One-touch fitting for ø4 SYA000 One-touch fitting for ø6 G 1 8 One-touch
More informationMULTISTAGE MICRO EJECTORS
MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]
More informationOrder from MARYLAND METRICS P.O. Box 261 Owings Mills, MD USA web:
Push-In Fittings LF 3000 LF 3200: 3 mm LIQUIfit LF 300 LF 300/ LF 3900 LF 0 PARKER LEGRIS Industrial Connector Systems Products are available from: MARYLAND METRICS P.O. Box 21 Owings Mills, MD 21117 USA
More information14,5 PSC PSP PSR. INTEGRATED SUB-BASE MANIFOLD valve with no subbase
PS COMBOBOX Valves PSC Single electric connection INTEGRATED SUB-BASE MANIFOLD valve with no subbase REDUCED DIMENSIONS Space saving up to 0% in comparison with standard valve MANIFOLDS HIGH FLOW RATE
More informationInnovative solutions for your handling projects
For a Compact and durable design, Look no further! Foams adjust to smooth and rough surfaces easily Level compensators allow the Mini-Gripper to adjust for uneven layer heights without changing the mount
More informationIndicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A
1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating
More informationCompressed Air Conditioning. accessories. One Stop Shop process reliable efficient economical high degree of reusability
Screwdriving technology Automation Air motors Air tools Compressed Air Conditioning and Accessories One Stop Shop process reliable efficient economical high degree of reusability DEPRAG offers a comprehensive
More informationOperating and Installation Instructions Diaphragm Vacuum Pumps and Compressors
Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected
More informationVacuum Generators. Section B.
Section www.parker.com/pneu/vacgen 2 asic Generator Selection How to Select a Generator 4-9 Inline : Single Stage MCA, CV, CV-CK MCA is lightweight generator that can be located directly on the cup fitting
More informationCUP ACCESSORIES SECTION 4 FLOW VALVES, CHECK VALVES, MECHANICAL VALVES, SWIVEL JOINTS, & TEE ADAPTORS EDCO USA.
CUP ACCESSORIES SECTION FLOW ALES, CHECK ALES, MECHANICAL ALES, SWIEL JOINTS, & TEE ADAPTORS 0 EDCO USA. www.edcousa.net : CUP ACCESSORIES CONTENTS DUAL FLOW ALE TRI-FLOW ALE FLOW SENSOR ALE RELEASE CHECK
More informationMICRO CUP HOLDERS
MICRO CUP HOLDERS 0 80 05 - Extremely reduced size and weight - Stainless steel stem and spring - Self-lubricating bush built in the threaded sleeve ensuring a perfect sliding of the stem and durability
More informationnickel-plated brass - PBT technopolymer HNBR, FKM stainless steel
CATALOGUE > Release 8.8 > Series A solenoid valves Series A directly operated solenoid valves /-way - Normally Closed (NC) and Normally Open (NO) 3/-way - Normally Closed (NC) and Normally Open (NO)»»
More informationElectrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)
Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to 0.966 Cv) Order code Series and function KM-09-510-HN-442 Standard coils HN at ports 2 + 4 HN at ports 1, 3
More informationData Sheet. RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve
Data Pack G Issued March 1997 1502323412 Data Sheet RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve The RS electro-pneumatic interface is a modular solenoid valve, purpose made
More informationMULTI JECTOR Vacuum Pumps
VOLKMANN MULTI JECTOR Vacuum Pumps and Vacuum Components by VOLKMANN multiple stage ejectors energy-saving compact ejectors stainless steel Vacuum Pumps vacuum switches vacuum filters VOLKMANN has been
More informationVacuum generators Key features
Vacuum generators Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The product families
More informationMULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle
More informationnickel-plated brass - PBT technopolymer HNBR, FKM stainless steel
CATALOGUE > Release 8.7 > Series A solenoid valves Series A directly operated solenoid valves /-way, 3/-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 - G1/8 - R1/8 - cartridge ø4
More informationVACUUM A RESOURCE FOR EVERYONE
Vacuum grippers VACUUM PRODUCTS INNOVATORS IN VACUUM TECHNOLOGY CATALOG VERSION 5.0 VACUUM A RESOURCE FOR EVERYONE www.piab.com Accessories Suction cups Vacuum pumps PVA VACUUM SWITCHES, INDUCTIVE UNIVERSAL
More informationErgonomic Handling Solutions. Vacuum Handling Systems Tube Lifters Jumbo and Lifting Devices VacuMaster
Ergonomic Handling Solutions Vacuum Handling Systems Tube Lifters Jumbo and Lifting Devices VacuMaster 53 Vacuum Tube Lifters Jumbo Introduction Application Fast and frequent lifting and moving of workpieces
More informationAIR SANDERS & POLISHERS
AIR SANDERS & POLISHERS The most complete line of air finishing tools. Ingersoll Rand finishing tools are designed for long-life and swirl-free finishes. 49 4151-HL High Performance 150 mm Random Orbital
More informationMiniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer
Miniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer Fastbreak Mini Series: VP0X & VP0X-ADJ VP0X-60 Fastbreak blow-off pump with vacuum cup, spring leveler assembly for rapid part release
More informationVacuum generators 1.1. High vacuum levels of up to 93% Easy connection of holders and suction cups. Lightweight and compact design.
High vacuum levels of up to 93% Easy connection of holders and suction cups Lightweight and compact design No wearing parts Long service life Vacuum monitoring with vacuum switch 2005/07 Subject to change
More informationParallel Grippers- DPDS DIRECTCONNECT Modular Series
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 426-548 www.cmafh.com 1.134 Parallel Grippers- DPDS DIRECTCONNECT Modular Series Mounting Information: Grippers
More informationMaterials: 10. Technical Data. VMAA Smart Pump Installation & Maintenance. Table of Contents
8 6 7 9 Part Identification. Jet Housing Module. Pilot Valve Assy.. Gasket Check Valve. M00 Manifold Assy.. Blind End Cap 6. Control Module for 7. Control Module for 8. Control Module for 9. M00 Manifold
More informationElectro-pneumatic control valves
Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve
More informationElectrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)
Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/4 1300 and 1580 Nl/min (1.321 and 1.606 Cv) Order code Series and function M-07-310-HN-442 Standard coil HN at port 2 + 4 HN at port
More information3 Porting options. for an optimized flow. 15 mm DIN For C Pilot Solenoid Valve. Stackable Valve Series - PVL-B22. PVL-B22 - Stackable Series
Stackable Valve Series - PVL-B22 PVL-B22 - Stackable Series Stacking high flow valves with 10 or 15mm DIN C Pilot Solenoid Valve. Light weight plastic bodies feature push-in or threaded connection. Stacking
More informationPMFO AIR/OIL SYSTEM PMFO AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS
AIR/OIL SYSTEM AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS (BLUE COLOUR ALUMINIUM BASE) The basic design of this system is similar to the PMF progressive, but with the inclusion of airways to enable
More informationSeries PD directly operated solenoid valves
> Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current
More informationGSW-V. Application example. Special Gripper Vacuum Gripper. Weight 0.12 kg 0.39 kg. Clamping diameter 20 mm 32 mm
GSW-V Suction pad diameter 30 mm 125 mm Clamping diameter 20 mm 32 mm Weight 0.12 kg 0.39 kg Gripping force 55 N 980 N Workpiece weight 0.28 kg 4.9 kg Application example Handling of gears in a milling
More informationControl block VOFA with safety function
Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,
More informationSuction Spares and Accessories 2009
MUL91600101 Black Rubber Feet for Machined Base Plates, (Pack of 5) MUL8150038 Black Rubber Feet for Machined Base Plates, (Pack of 4) b MUL94004000 Illuminated Green Rocker Switch (L30mm x W25mm x D30mm)
More informationPRESS G SERIES. Two Stage Light Oil Burners FIRING RATES
The PRESS G series of burners covers a firing range from 107 to 1660 kw and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups
More informationVP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3.
Modular Venturi Vacuum Pumps Mid Series VP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3.2 VP1X Series Pneumatic Blow-Off
More informationBlow Guns. Associated Products , Jet Air Nozzles. Air Boy Blow Guns Blow Gun
12 Cleaning Guns Air/Water Boy Blow Gun Jet Air Nozzles 541-543 544 544 545 Inflating Guns Sodablasters & Accessories 600 Series Blow Gun System Pistol Air 545 546 547 548-549 Blow Pen Blow Gun Nozzles
More informationElectrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)
Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationElectrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)
Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to 1.001 Cv) Order code BM-02-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationSeries P directly operated solenoid valves
> Series P solenoid valves CATALOGUE > Release 8.7 Series P directly operated solenoid valves 3/-way NC and NO. The solenoid valves can be mounted on a single base (with M5 ports) as well as on manifolds
More informationHow to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K
Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K 5 08 25-ZK2 12 0 08 q w e r t y u i Remains blank when option is not selected.
More informationMega Series. gas service carts L170R01 / L280R.. / L550R.. Maintenance devices for large and extra large gas compartments L170R01 / L280R.. / L550R..
s Mega Series Maintenance devices for large and extra large gas compartments These service carts are our most powerful devices and guarantee quick maintenance of gas compartments. Thanks to the state-of-the-art
More informationSeries RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C
Technical details Temperature range Medium -0 C... +50 C Filtered, oil-free and dried compressed air according to ISO 857-:00, Class 7::, instrument air, free of aggressive additives. Alternatively the
More informationElectrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)
Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationSBM TECHNOLOGY PET Blow Valve Block
Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)
More informationGROUP 3B CLEANER AIR SYSTEM CONTENTS
3B-0 GROUP 3B CLEANER AIR SYSTEM CONTENTS SECTION 0 GENERAL 1 2. Removal and Installation 3 3 SECTION 1 SUB TANK 2 2-2 Installation 3 2 2-3 Inspection and Maintenance 3 2. Removal and Installation 2 9
More informationMiniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off
Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off Fastvac Mini Series: VP01QR-60 VP01QR-60H/24vDC Standard
More informationPneumatics. Switching, automation systems, directional control in industrial and explosive atmospheres. Overview. b Switching.
Pneumatics Switching, automation systems, directional control in industrial and explosive atmospheres Overview b Switching b Control systems b Directional control Overview Pneumatics Contents b Presentation
More information2/2 Pressure operated valves
Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54
More informationProdigy HDLV System Troubleshooting - Generation III
Prodigy HDLV System Troubleshooting - Generation III Instruction Sheet P/N 1081071-05 Use the procedures listed in this document to isolate and correct common problems with Prodigy HDLV Systems. Refer
More informationOperating instructions Compact ejector SCPS. Innovative Vacuum for Automation /
#NP#_ TU5 da8iwf P0rJU8 bmzv NU2v dy9 KkQdlWwYmyERixTbGsayVG9iH+r T3tzT+2FF8 G9+H cez7uoykiajmjm NWsBBMgA o4ynmsmkzie QZ KScUhxnKZhRHE YROA0 cize KYdcWX0VRCi KM XJcM hrfiizqtrycasjrpl U5Iduaem9r 1frC6K+7fbF9V82
More informationMACH 16 VALVES DISTRIBUTORS
MACH 16 VALVES Available in size 1/8 only, versions 5/2 and 5/3 and with pneumatic and solenoid actuation. The mach 16 valve is a typical small size valve, only 16 mm wide, with excellent performance 750
More informationElectronic Pressure Switch EDS 3000
Description: The EDS 3000 is a compact, electronic pressure switch with integral digital display. The unit can have one or two switching outputs, and there is the option of an additional analogue output
More informationSOLENOID VALVES AND PNEUMATIC VALVES
A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly
More informationPressure Switches. Pressure switches, pneumatic. Pressure switches, electronic
Contents Description Page Pressure switches, pneumatic, with plug 50 Pressure switches, pneumatic, with flat pins 51 Pressure switches, pneumatic 52 55 with internal thread with flange connection Pressure
More information