Simple venturis, series GVP

Size: px
Start display at page:

Download "Simple venturis, series GVP"

Transcription

1 Simple venturis, series GVP 5-bar compressed air network L1 Exhaust D1 L 1/4 gas, 6x8 quick-connect or 4x6 quick-connect D 30 Connection for options 6 Vacuum 1/ gas Vacuum generators in series GVP are the basic venturis in the modular range. Recommended for applications without control, they are available at 5 different power levels (evacuation time) and 3 different vacuum levels: version X with 50% vacuum for very porous products, version T with 75% for porous products and version N with 90% vacuum for sealed products. The suction flow rate increases as the maximum vacuum level decreases, with the same nozzle diameter. As well as being used with suction cups, they can be used for the purposes of liquid metering, spraying and tank depressurization, etc Tube 4x6 connection ø consumption as % Nl/min mm Gas mm mm Models mm Nl/mn X T N X T N X N/T X N/T X N/T S K(N/T) K(X) GVP / 1/ GVP / 1/ GVP / 1/ GVP / 1/ GVP / 1/ On standard basis, versions N and T are supplied with silencer S and version X is supplied with silencer K, except for model GVP 30 which is always equipped with silencer K. Temperature -10 to 80 C Optimal pressure Body material DELRIN GVP mm 5.5 mm 30 3 mm X 50% vacuum 14 1/4 G BSPP 46 tube 4/6 calibrated 68 tube 6/8 calibrated Note: Versions N and T: silencer S and K Version X: silencer K 01.0

2 V A C U U M H A N D L I N G Selecting a venturi Evacuation time in seconds for 1 litre: % VACUUM GV 05 N VR GVA VR GVA VR GV 10 N GVP 1 N GV 15 N GVP 15 N GV 0 N GVP 0 N GVP 5 N GVP 30 N % VACUUM GVP 1 T GVP 15 T GVP 0 T GVP 5 T GVP 30 T % VACUUM GV 05 X GV 10 X GVP 1 X GV 15 X GVP 15 X GV 0 X GVP 0 X GVP 5 X GVP 30 X Weight of venturis in grams: MODELS GVP GVPS GVPD GVC GVCS GVS OPTIONS GVO PSE100 E Electrical output vacuum switch g GVO PSE100 EC Electrical output vacuum switch with connector g GVO PSL100 PNP Electronic vacuum switch g GVO PSA100 PNP Display type electronic vacuum switch g GVO VAF11140 Vacuum gauge VAF g CONTROLLERS Pneumatic controller g Electric controller g

3 Venturis with automatic blow-off, series GVC H6 5-bar compressed air network Connection for options 13 8, 35 Blowing flow restrictor 49. Vacuum 1/ gas L Plug, 1/8 gas, for boosted blowing 1/4 gas, 6x8 quick-connect Exhaust or 4x6 quick-connect L Vacuum generators in series GVC are venturis with automatic blow-off. This special feature allows the part gripped to be released automatically, so speeding up work rates and simplifying the wiring of the venturi. For control of vacuum generation, see the GVCS range. The addition of a 1/8 gas type male connection on the unit allows the fitting of a supplementary compressed air tank to increase the blowing capacity, e.g. for large-diameter suction cups. D1 D Tube 4x6 Compressed air connection 1 ø consumption as % Nl/min mm Gas mm mm Models mm Nl/min T N T N N/T N/T N/T S K GVC / GVC / On standard basis, supplied with silencer S. Temperature 0 to 60 C Unit material DELRIN 500, grey and blue Optimal pressure Blowing flow rate Adjustable by flow restrictor Body material DELRIN Hz Blowing adjustment on bottom for manifold installation. Provision of a 1/8 gas type port on front for connection of a vacuum gauge. Specific features (on request): The auto blow-off function is also available with more powerful vacuum generators ( and.5 mm nozzles). GVC BSPP 46 tube 4x6 calibrated Note: Versions N and T: silencer S

4 V A C U U M H A N D L I N G Selecting a venturi Evacuation time in seconds for 1 litre: % VACUUM GV 05 N VR GVA VR GVA VR GV 10 N GVP 1 N GV 15 N GVP 15 N GV 0 N GVP 0 N GVP 5 N GVP 30 N % VACUUM GVP 1 T GVP 15 T GVP 0 T GVP 5 T GVP 30 T % VACUUM GV 05 X GV 10 X GVP 1 X GV 15 X GVP 15 X GV 0 X GVP 0 X GVP 5 X GVP 30 X Weight of venturis in grams: MODELS GVP GVPS GVPD GVC GVCS GVS OPTIONS GVO PSE100 E Electrical output vacuum switch g GVO PSE100 EC Electrical output vacuum switch with connector g GVO PSL100 PNP Electronic vacuum switch g GVO PSA100 PNP Display type electronic vacuum switch g GVO VAF11140 Vacuum gauge VAF g CONTROLLERS Pneumatic controller g Electric controller g 0.00

5 Controlled venturis, series GVPS Ø Manual control 5-bar compressed air network 5 35 Electric control Exhaust D1 L D H13 1/4 gas or 6x8 quick-connect Connection for options 4 6 Vacuum 1/ gas Vacuum generators in series GVPS control vacuum generation by means of an integrated valve. This installation simplifies wiring and reduces venturi response times. The valve can be controlled electrically (all voltages) or pneumatically (control by pneumatic logic and for explosion-proof conditions). L Tube 6/8 ø consumption as % Nl/min mm Gas mm mm Models mm Nl/min X T N X T N X N/T X N/T X N/T S K(N/T) K(X) GVPS / 1/ GVPS / 1/ GVPS / 1/ GVPS / 1/ GVPS / 1/ On standard basis, versions N and T are supplied with silencer S and version X is supplied with silencer K, except for model GVPS 30 which is always equipped with silencer K. Temperature 0 to 60 C Optimum pressure Max. valve flow rate 750 Nl/min at 5 bar N of valve operations 15 million Hz maximum Function N.C. Function N.O. at 4 V DC on request Valve / Body material DELRIN 100 GVPS mm 5.5 mm 30 3 mm X 50% vacuum /4 G BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V - 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 Note: Versions N and T: silencer S and K Version X: silencer K

6 V A C U U M H A N D L I N G Selecting a venturi Evacuation time in seconds for 1 litre: % VACUUM GV 05 N VR GVA VR GVA VR GV 10 N GVP 1 N GV 15 N GVP 15 N GV 0 N GVP 0 N GVP 5 N GVP 30 N % VACUUM GVP 1 T GVP 15 T GVP 0 T GVP 5 T GVP 30 T % VACUUM GV 05 X GV 10 X GVP 1 X GV 15 X GVP 15 X GV 0 X GVP 0 X GVP 5 X GVP 30 X Weight of venturis in grams: MODELS GVP GVPS GVPD GVC GVCS GVS OPTIONS GVO PSE100 E Electrical output vacuum switch g GVO PSE100 EC Electrical output vacuum switch with connector g GVO PSL100 PNP Electronic vacuum switch g GVO PSA100 PNP Display type electronic vacuum switch g GVO VAF11140 Vacuum gauge VAF g CONTROLLERS Pneumatic controller g Electric controller g

7 Controlled venturis with automatic blow-off, series GVCS Vacuum generators in series GVCS are of identical design to series GVC. Their special feature is vacuum generation control by means of an integrated valve. The valve control function speeds up response times and makes wiring easier by integrating all functions. For longer blow-off, see the GVPD range. The addition of a 1/8 gas type coupling on the unit allows the connection of a supplementary compressed air tank to increase the blowing capacity, e.g. for large-diameter suction cups. ø consumption as % Nl/mn mm Gas mm mm Models mm Nl/min T N T N N/T N/T N/T S K GVCS / GVCS / On standard basis, supplied with silencer S. Temperature 0 to 60 C Capacity material DELRIN 500, grey and blue Optimum pressure Blowing flow rate Adjustable by flow restrictor. N of valve operations 15 million Hz maximum Function N.C. Function N.O. at 4 V DC on request Valve / body material DELRIN 100 Possibility of increasing capacity volume. GVCS 1 Note: Versions N and T: silencer S and K Version X: silencer K BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V- 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 v 03 5

8 Venturis with gripping & blow-off control, series GVPD Vacuum generators in series GVPD control vacuum generation and blowing (with adjustable flow rate). The control of blowing, in terms of power and time, speeds up gripping/releasing rates, allows parts to be cleaned before gripping, and improves release for large diameter suction cups. ø consumption as % Nl/min mm Gas mm mm Models mm Nl/min X T N X T N X N/T X N/T X N/T S K(N/T) K(X) GVPD / 1/ GVPD / 1/ GVPD / 1/ GVPD / 1/ GVPD / 1/ On standard basis, versions N and T are supplied with silencer S and version X is supplied with silencer K, except for model GVP 30 which is always equipped with silencer K. N of valve operations 15 million Hz maximum Valve function N.C. Valve function N.O. at 4 V DC on request Valve/body material DELRIN 100 Optimal pressure Blowing flow rate 30 Nl/min closed, 60 Nl/min open GVPD mm 5.5 mm 30 3 mm X 50% vacuum Note: Versions N and T: silencer S and K Version X: silencer K /4 G BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V - 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 v 03 6

9 Safety venturis with blow-off, series GVS The vacuum generator in the GVS series is more commonly known as a safety venturi. Like those in the GVPD range, it has integrated vacuum generation and blowing. In addition, two safety non-return valves hermetically blank off the vacuum circuit in the event of failure of either of the two power sources (electric and/or pneumatic). It therefore ensures that parts remain gripped. Caution: Parts to be handled must be of the non-porous type. Characteristics Nozzle Air Max. Drawn-in air D D1 L1* L ø consumption vacuum Models mm Nl/min as % Nl/min mm Gas mm mm N S K GVS / GVS / GVS / GVS / GVS / (*): L1 equipped with standard silencer N of valve operations 15 million Hz maximum Valve function N.C. Valve function N.O. at 4 V DC on request Valve/body material Aluminium Optimal pressure Work rate Less than 0 cycles per minute GVS mm 5.5 mm 30 3 mm /4 G BSPP 5 5: Control P1 Pneumatic E1 4 V DC, N.C. E 0 V - 50 Hz E3 4 V AC E6 4 V DC, N.O. E.. Others, page 37 v 03 7

Micro-venturis, series GVA

Micro-venturis, series GVA Micro-venturis, series GVA Reference V : vacuum outlet Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. or Male coupling, 4 mm dia.,. mm long ø. 4... Version GVA -- 44 GVASIL or GVASPO

More information

Multi-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications

Multi-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications Multi-Stage Ejectors Suction rate from 332 l/min to 2,370 l/min Suitability for Industry-Specific Applications Applications Multi-stage ejector for handling of cardboard, packing materials, insulating

More information

LEM. mini-modules compact integrated vacuum pumps. US3

LEM. mini-modules compact integrated vacuum pumps.   US3 mini-modules compact integrated pumps LEM TM www.coval.com US3 LEM LEM series: mini-module pressure OUT IN 2 exhaust TM certified quality management system All industrial functions integrated into the

More information

mini-modules compact integrated vacuum pumps LEM

mini-modules compact integrated vacuum pumps LEM mini-modules compact integrated pumps LEM TM www.coval.com LEM LEM series: mini-module pressure OUT IN 2 exhaust TM All industrial functions integrated into the mini-module Efficient communication for

More information

Vacuum generation Compact ejectors

Vacuum generation Compact ejectors Energy saving function by integrated pressure control saves up to 5 % of energy q = Vacuum connection z = Compressed air connection Product notes s = Exhaust outlet Check valve with wire mesh to keep out

More information

LEM. mini-modules compact integrated vacuum pumps. US5

LEM. mini-modules compact integrated vacuum pumps.  US5 mini-modules compact integrated pumps LEM TM www.coval.com US5 LEM LEM Series: Mini-Module pressure OUT IN 2 exhaust TM certified quality management system 40% energy savings (on average, see p.5). No

More information

VACUUM PUMP Midi Keyboard Pump

VACUUM PUMP Midi Keyboard Pump Midi Keyboard Pump Max. vacuum level Max. flow rate Supply air pressure Supply air type : VKX pump -92 kpa (-27.16 inhg) VKM pump -85 kpa (-25.1 inhg) : VKX pump 62 Nl/min (2.19 scfm) VKM pump 74 Nl/min

More information

LEMAX. mini-modules. "ASC" compact vacuum pumps US2

LEMAX. mini-modules.  ASC compact vacuum pumps US2 mini-modules LEMAX "ASC" compact pumps TM www.coval.com US2 OUT IN pressure LEMAX series: compact P = 4 to 8 bar 3.5 bar blow-off exhaust 2 ➊ ➋ ➌ ➍ ➎ 3.5 bar pressure regulator "Vacuum" solenoid valve

More information

Vacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK

Vacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK VACUUM VENTURI CV VACUUM VENTURI Anodized aluminum body All metal construction Maximum vacuum of 27 Hg Vacuum flow rates up to 8CFM Single stage technology HSK s include part presence switch R N CV 15

More information

Vacuum Generators. Catalogue Edition 2

Vacuum Generators. Catalogue Edition 2 Vacuum Generators Catalogue Edition 2 Switch Options S = SK = The fixed switch option is normally open and changes position at 12 Hg The adjustment of the SK model switch is between 6-16 Hg Features: Anodized

More information

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer Type Ejector Ambient temperature min./max. + C / + C Medium temperature min./max. + C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed

More information

General characteristics Operating fluid Compressed air or inert gas Conditions of use Operating pressure 30 to 20 PSI (2 to 8 bars). Fluid: Filtered a

General characteristics Operating fluid Compressed air or inert gas Conditions of use Operating pressure 30 to 20 PSI (2 to 8 bars). Fluid: Filtered a Pneumatic Logic Components Order/Technical Support Tel: (800) 67753 / FAX: (800) 6773865 / www.crouzetusa.com 5/3 5 General characteristics Operating fluid Compressed air or inert gas Conditions of use

More information

Multi-Stage Air Powered Vacuum Pumps

Multi-Stage Air Powered Vacuum Pumps Multi-Stage Powered Pumps The MSP Series Multi-Stage Pneumatically-Driven Pumps operate on the Venturi Principle. These pumps are designed for applications requiring high flows at moderate vacuum levels.

More information

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings Flow Control Regulators Piloted Non-Return Valves LIQUIfit Pressure Fittings Other Silencers Flow Control Regulators (P. 4-6) Blocking Fittings (P. 4-36) Piloted Non-Return Valves (P. 4-38) Function:

More information

Chain lubrication unit WS-E

Chain lubrication unit WS-E Product description Chain lubrication unit WS-E APPLICATION The central lubrication system WS- E is used for automatic and metered lubrication of chains, joints, rollers, hinges, etc. This system is also

More information

COILS, CONNECTORS, SOLENOID VALVES

COILS, CONNECTORS, SOLENOID VALVES COILS, CONNECTORS, SOLENOID VALVES 117 10 mm solenoids Solenoid valve 10 mm 00.441.0 Tension 24V DC ±10% Temperature range -5 C...+60 C (23 F... 140 F) Power 0.5... 1 W Operating pressure 0... 7 bar (0...

More information

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer Type Ejector Ambient temperature min./max. +0 C / + C Medium temperature min./max. +0 C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed

More information

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm > Series E valves and solenoid valves Series E valves and solenoid valves 5/-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm Series

More information

Vacuum technology Moduflex vacuum generator Peripheral module

Vacuum technology Moduflex vacuum generator Peripheral module Vacuum technology Moduflex generator Peripheral module Catalogue PDE2548SLUK-ev Moduflex generator Summary Page Applications... 3 Vacuum technology... 4 Order codes...5 Complete generators and stand alone

More information

VACUUM CUP SUPPORTS. 3D drawings available at

VACUUM CUP SUPPORTS. 3D drawings available at In the following pages are listed the cups for which each support is suited. They are specially shaped to perfectly adhere to the internal profile of the cups and they are provided with a male or female

More information

Solenoid valves "ENOVA" Series 2300

Solenoid valves ENOVA Series 2300 Solenoid valves "ENOVA" Series 300.04 Series 300 Solenoid valves "ENOVA".05 Solenoid valves "ENOVA" Series 300 Solenoid - Differential (Monostable) 5/ 3eC.5.00.36.v ELECTRICAL CONTACTS 0=STANDARD-only

More information

Valves and Solenoid valves Series E 2/

Valves and Solenoid valves Series E 2/ CATALOGUE > Release 8.6 > Series E valves and solenoid valves Valves and Solenoid valves Series E 5/-way monostable/bistable - 5/3 CC CO CP With outlets on the body - For individual or manifold assembly

More information

Solenoid valves "OPTYMA32-S" General. Series 2200

Solenoid valves OPTYMA32-S General. Series 2200 1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational

More information

Solenoid valves "OPTYMA32-S" General. Series 2200

Solenoid valves OPTYMA32-S General. Series 2200 1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational

More information

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2 1-4009-EN PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2 The PTEX extruder pumps are pneumatically actuated pumps designed to deliver lubricant under pressure to lubrication

More information

PSP PSP PSC PSR TECHNICAL CHARACTERISTICS. ComboBox series. Valves. Flow rates according to fittings:

PSP PSP PSC PSR TECHNICAL CHARACTERISTICS. ComboBox series. Valves. Flow rates according to fittings: ComboBox series The new ComboBox valves are the result of long reflections regarding the requirements of the modern user, the current market demands, the ever increasing needs in the ergonomical and ecological

More information

Solenoid valves "OPTYMA32-S" General. Series 2200

Solenoid valves OPTYMA32-S General. Series 2200 1 General Series 2200 1 Series 2200 Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN Weight gr. 67 SHORT FUNCTION CODE "A" Serie Solenoid 2200-S-GB valves - Spring "OPTYMA32-S"

More information

REVERSIBLE HYDRAULIC POWER PACKS. 1 node/142/

REVERSIBLE HYDRAULIC POWER PACKS. 1 node/142/ REVERSIBLE HYDRAULIC POWER PACKS 1 node/142/ 2 Introduction Oil Sistem is a leader in power packs production and offers a wide range of solutions suitable for every type of application. Oil Sistem developed

More information

1 01 / 201 Edition ED. 01/2007

1 01 / 201 Edition ED. 01/2007 Edition 01 / 2011 ED. 01/2007 TABLE OF CONTENENTS 1 INTRODUCTION 2 GRIPPER EXAMPLES 2.1 EXAMPLE A: GRIPPER WITH TUBES AND ALUMINIUM PROFILES 2.2 EXAMPLE B: GRIPPER WITH STAINLESS STEEL TUBES 2.3 EXAMPLE

More information

Catalog 080-/USA Notes Vacuum Control Valves

Catalog 080-/USA Notes Vacuum Control Valves Vacuum Control Valves Section Catalog 080-/USA Notes Vacuum Control Valves Catalog 080-/USA Index Vacuum Control Valves VA0 Vacuum Control Valves for Centralized Vacuum Systems VA0PSV & VA0PSP, -Port,

More information

ZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector

ZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector Pressure Switch Model Selection Table Self-contained Type ZSE20(F) ZSE30A(F) ISE30A ZSE40A(F) ISE40A ZSE10(F) Model Fluid Calibration method Set pressure range Power supply voltage 105 to 105 kpa 10 to

More information

Valve Islands Series F

Valve Islands Series F CATALOGUE > s 01 Valve Islands Series F > Valve Island Series F Multipole integrated electrical connection (PNP) Valve functions: x/; x3/; 5/; 5/3 CC The use of technopolymer in this Series has allowed

More information

Vacuum Components SHREE VYANKATESHWARA E N T E R P R I S E S

Vacuum Components SHREE VYANKATESHWARA E N T E R P R I S E S CKD Actuators Pneumatic Valves Pneumatic Auxiliary Components Pneumatic Auxiliary Components (Main Line Unit) Pneumatic Filter, Regulator, Lubricator (F.R.L. Unit) Related Pneumatic Products DD Actuator

More information

VACUUM PUMP P5010. Profit from new vacuum technology

VACUUM PUMP P5010. Profit from new vacuum technology VACUUM PUMP P5010 COAX THE NEXT DIMENSION IN VACUUM TECHNOLOGY Profit from new vacuum technology Patented COAX push-in technology Efficient use of energy Outstanding performance Slim and modular design

More information

With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-

With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM- Features and Benefits Solenoid-Actuated Vacuum Generators Types VADM-... / VADMI-... l Integral Filter, Silencer, Manual Override l Integral Solenoid Valve for Controlling Air Supply l Vacuum Range up

More information

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS SYSTEM ACCESSORIES SECTI 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS 6 2012 EDCO USA. www.edcousa.net 6:1 6 SYSTEM ACCESSORIES CTENTS VACUSTAT MECHANICAL PRESSURE SWITCH INLINE VACUUM FILTER

More information

SPRAY GUN ACCESSORIES & ANCILLARY EQUIPMENT

SPRAY GUN ACCESSORIES & ANCILLARY EQUIPMENT SPRAY GUN ACCESSORIES & ANCILLARY EQUIPMENT A15 - Accessory Kit 5 piece air tool kit, consisting of the most popular items Lightness, balance and manufactured to the highest quality Designed to use with

More information

SECTION 7 AX SERIES PUMPS

SECTION 7 AX SERIES PUMPS SECTION X SERIES PUMPS EDCO US www.edcousa.net : X PUMPS Z - ZERO BSE G /8 NPSF G / NPSF LRGE CPCITY G / NPSF General Information : Z: Zero Base (No Base) :4 G/8 NPSF Bases :5 - :6 G/ NPSF Bases : - :

More information

PI 1 Plug-in Injector

PI 1 Plug-in Injector Operating Instructions and Spare Parts List PI 1 Plug-in Injector PI 1 1 12 PI 1 Table of contents PI 1 Plug-in injector for organic powders................................... 1 Fields of application....................................................

More information

Series ISA. Air Catch Sensor. For Detection of Work Presence

Series ISA. Air Catch Sensor. For Detection of Work Presence ED Bar graph for easy calibration The ED bar graph indicator in conjunction with the adjustment knob for the variable orifice allows for easy and correct calibrations. Over range (Red) Correct range (Green)

More information

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. Pressure Fittings. Other Function Fittings.

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. Pressure Fittings. Other Function Fittings. Function Fittings Flow Control Regulators Piloted Function Fittings Non-Return Valves Pressure Fittings Other Function Fittings Silencers Function Fittings 4-3 Function Fittings Flow Control Regulators

More information

AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block

AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block INSTRUCTION MANUAL AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block Manual : 0306 573.002.212 Date : 12/06/03 Supersedes : 17/06/02 Modif. 1 + 4 added KREMLIN REXSON Site de Stains : 150,

More information

L170R01 SF 6. For liquid storage. gas service cart. 10" touch panel. Technical data: Dimensions: L mm, W mm, H mm Weight: 890 kg

L170R01 SF 6. For liquid storage. gas service cart. 10 touch panel. Technical data: Dimensions: L mm, W mm, H mm Weight: 890 kg For liquid storage L170R01 10" touch panel Technical data: Dimensions: L 2.250, W 1.050, H 1.220 Weight: 890 kg C 2980-06 Service carts L170R.. / L280R.. / L550R.. Mega Series For liquid storage L280R..

More information

Lockable isolation 3/2-way valves Series MX 3/

Lockable isolation 3/2-way valves Series MX 3/ CATALOGUE > Release 8.5 > /2-way isolation valves Series MX Lockable isolation /2-way valves Series MX New MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Modular Manual, electro-pneumatic, servo-pilot and

More information

Line-Mounted Valves L Series. L1 / L2 Series Overview L22 BA4 52. Valve Function. Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* =

Line-Mounted Valves L Series. L1 / L2 Series Overview L22 BA4 52. Valve Function. Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* = How to order: (example) Line-Mounted L Series L1 / L2 Series Overview L22 BA4 52 Function Function Mounting BA4 = BB4 = PP6 = PP7 = 52 = Line mounted 00* = Manifold mounted w/o Adapter * L11 / L12 series

More information

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics ir Service Units Filter pressure regulator + Lubricator - Size Series 00 Construction and working characteristics - Zinc alloy body or reinforced technopolymer body with threaded brass insert connections.

More information

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8 Port Air Operated Valve SYA000/000/7000 How to Order Symbol M C6 01F C6 02F C10 Without bracket A/B port size Port size Series M One-touch fitting for ø4 SYA000 One-touch fitting for ø6 G 1 8 One-touch

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD USA web:

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD USA   web: Push-In Fittings LF 3000 LF 3200: 3 mm LIQUIfit LF 300 LF 300/ LF 3900 LF 0 PARKER LEGRIS Industrial Connector Systems Products are available from: MARYLAND METRICS P.O. Box 21 Owings Mills, MD 21117 USA

More information

14,5 PSC PSP PSR. INTEGRATED SUB-BASE MANIFOLD valve with no subbase

14,5 PSC PSP PSR. INTEGRATED SUB-BASE MANIFOLD valve with no subbase PS COMBOBOX Valves PSC Single electric connection INTEGRATED SUB-BASE MANIFOLD valve with no subbase REDUCED DIMENSIONS Space saving up to 0% in comparison with standard valve MANIFOLDS HIGH FLOW RATE

More information

Innovative solutions for your handling projects

Innovative solutions for your handling projects For a Compact and durable design, Look no further! Foams adjust to smooth and rough surfaces easily Level compensators allow the Mini-Gripper to adjust for uneven layer heights without changing the mount

More information

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A 1 3 Port Air Operated Valve Series VTA301 JIS Symbol VTA 301 Indicate VO for manifold. Port size Specifications How to Order Without connection port (For manifold) 01 1/8 02 1/4 Option Fluid Air Operating

More information

Compressed Air Conditioning. accessories. One Stop Shop process reliable efficient economical high degree of reusability

Compressed Air Conditioning. accessories. One Stop Shop process reliable efficient economical high degree of reusability Screwdriving technology Automation Air motors Air tools Compressed Air Conditioning and Accessories One Stop Shop process reliable efficient economical high degree of reusability DEPRAG offers a comprehensive

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Vacuum Generators. Section B.

Vacuum Generators. Section B. Section www.parker.com/pneu/vacgen 2 asic Generator Selection How to Select a Generator 4-9 Inline : Single Stage MCA, CV, CV-CK MCA is lightweight generator that can be located directly on the cup fitting

More information

CUP ACCESSORIES SECTION 4 FLOW VALVES, CHECK VALVES, MECHANICAL VALVES, SWIVEL JOINTS, & TEE ADAPTORS EDCO USA.

CUP ACCESSORIES SECTION 4 FLOW VALVES, CHECK VALVES, MECHANICAL VALVES, SWIVEL JOINTS, & TEE ADAPTORS EDCO USA. CUP ACCESSORIES SECTION FLOW ALES, CHECK ALES, MECHANICAL ALES, SWIEL JOINTS, & TEE ADAPTORS 0 EDCO USA. www.edcousa.net : CUP ACCESSORIES CONTENTS DUAL FLOW ALE TRI-FLOW ALE FLOW SENSOR ALE RELEASE CHECK

More information

MICRO CUP HOLDERS

MICRO CUP HOLDERS MICRO CUP HOLDERS 0 80 05 - Extremely reduced size and weight - Stainless steel stem and spring - Self-lubricating bush built in the threaded sleeve ensuring a perfect sliding of the stem and durability

More information

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel CATALOGUE > Release 8.8 > Series A solenoid valves Series A directly operated solenoid valves /-way - Normally Closed (NC) and Normally Open (NO) 3/-way - Normally Closed (NC) and Normally Open (NO)»»

More information

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv) Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to 0.966 Cv) Order code Series and function KM-09-510-HN-442 Standard coils HN at ports 2 + 4 HN at ports 1, 3

More information

Data Sheet. RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve

Data Sheet. RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve Data Pack G Issued March 1997 1502323412 Data Sheet RS electro-pneumatic interface 3/2 and 4/2 manifold mounted solenoid valve The RS electro-pneumatic interface is a modular solenoid valve, purpose made

More information

MULTI JECTOR Vacuum Pumps

MULTI JECTOR Vacuum Pumps VOLKMANN MULTI JECTOR Vacuum Pumps and Vacuum Components by VOLKMANN multiple stage ejectors energy-saving compact ejectors stainless steel Vacuum Pumps vacuum switches vacuum filters VOLKMANN has been

More information

Vacuum generators Key features

Vacuum generators Key features Vacuum generators Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The product families

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel CATALOGUE > Release 8.7 > Series A solenoid valves Series A directly operated solenoid valves /-way, 3/-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 - G1/8 - R1/8 - cartridge ø4

More information

VACUUM A RESOURCE FOR EVERYONE

VACUUM A RESOURCE FOR EVERYONE Vacuum grippers VACUUM PRODUCTS INNOVATORS IN VACUUM TECHNOLOGY CATALOG VERSION 5.0 VACUUM A RESOURCE FOR EVERYONE www.piab.com Accessories Suction cups Vacuum pumps PVA VACUUM SWITCHES, INDUCTIVE UNIVERSAL

More information

Ergonomic Handling Solutions. Vacuum Handling Systems Tube Lifters Jumbo and Lifting Devices VacuMaster

Ergonomic Handling Solutions. Vacuum Handling Systems Tube Lifters Jumbo and Lifting Devices VacuMaster Ergonomic Handling Solutions Vacuum Handling Systems Tube Lifters Jumbo and Lifting Devices VacuMaster 53 Vacuum Tube Lifters Jumbo Introduction Application Fast and frequent lifting and moving of workpieces

More information

AIR SANDERS & POLISHERS

AIR SANDERS & POLISHERS AIR SANDERS & POLISHERS The most complete line of air finishing tools. Ingersoll Rand finishing tools are designed for long-life and swirl-free finishes. 49 4151-HL High Performance 150 mm Random Orbital

More information

Miniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer

Miniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer Miniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer Fastbreak Mini Series: VP0X & VP0X-ADJ VP0X-60 Fastbreak blow-off pump with vacuum cup, spring leveler assembly for rapid part release

More information

Vacuum generators 1.1. High vacuum levels of up to 93% Easy connection of holders and suction cups. Lightweight and compact design.

Vacuum generators 1.1. High vacuum levels of up to 93% Easy connection of holders and suction cups. Lightweight and compact design. High vacuum levels of up to 93% Easy connection of holders and suction cups Lightweight and compact design No wearing parts Long service life Vacuum monitoring with vacuum switch 2005/07 Subject to change

More information

Parallel Grippers- DPDS DIRECTCONNECT Modular Series

Parallel Grippers- DPDS DIRECTCONNECT Modular Series Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 426-548 www.cmafh.com 1.134 Parallel Grippers- DPDS DIRECTCONNECT Modular Series Mounting Information: Grippers

More information

Materials: 10. Technical Data. VMAA Smart Pump Installation & Maintenance. Table of Contents

Materials: 10. Technical Data. VMAA Smart Pump Installation & Maintenance. Table of Contents 8 6 7 9 Part Identification. Jet Housing Module. Pilot Valve Assy.. Gasket Check Valve. M00 Manifold Assy.. Blind End Cap 6. Control Module for 7. Control Module for 8. Control Module for 9. M00 Manifold

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve

More information

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv) Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/4 1300 and 1580 Nl/min (1.321 and 1.606 Cv) Order code Series and function M-07-310-HN-442 Standard coil HN at port 2 + 4 HN at port

More information

3 Porting options. for an optimized flow. 15 mm DIN For C Pilot Solenoid Valve. Stackable Valve Series - PVL-B22. PVL-B22 - Stackable Series

3 Porting options. for an optimized flow. 15 mm DIN For C Pilot Solenoid Valve. Stackable Valve Series - PVL-B22. PVL-B22 - Stackable Series Stackable Valve Series - PVL-B22 PVL-B22 - Stackable Series Stacking high flow valves with 10 or 15mm DIN C Pilot Solenoid Valve. Light weight plastic bodies feature push-in or threaded connection. Stacking

More information

PMFO AIR/OIL SYSTEM PMFO AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS

PMFO AIR/OIL SYSTEM PMFO AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS AIR/OIL SYSTEM AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS (BLUE COLOUR ALUMINIUM BASE) The basic design of this system is similar to the PMF progressive, but with the inclusion of airways to enable

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current

More information

GSW-V. Application example. Special Gripper Vacuum Gripper. Weight 0.12 kg 0.39 kg. Clamping diameter 20 mm 32 mm

GSW-V. Application example. Special Gripper Vacuum Gripper.   Weight 0.12 kg 0.39 kg. Clamping diameter 20 mm 32 mm GSW-V Suction pad diameter 30 mm 125 mm Clamping diameter 20 mm 32 mm Weight 0.12 kg 0.39 kg Gripping force 55 N 980 N Workpiece weight 0.28 kg 4.9 kg Application example Handling of gears in a milling

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

Suction Spares and Accessories 2009

Suction Spares and Accessories 2009 MUL91600101 Black Rubber Feet for Machined Base Plates, (Pack of 5) MUL8150038 Black Rubber Feet for Machined Base Plates, (Pack of 4) b MUL94004000 Illuminated Green Rocker Switch (L30mm x W25mm x D30mm)

More information

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES The PRESS G series of burners covers a firing range from 107 to 1660 kw and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups

More information

VP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3.

VP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3. Modular Venturi Vacuum Pumps Mid Series VP10 Series Compact and lightweight, the VP10 Series is designed for versatile performance in limited space applications. See Page... 3.2 VP1X Series Pneumatic Blow-Off

More information

Blow Guns. Associated Products , Jet Air Nozzles. Air Boy Blow Guns Blow Gun

Blow Guns. Associated Products , Jet Air Nozzles. Air Boy Blow Guns Blow Gun 12 Cleaning Guns Air/Water Boy Blow Gun Jet Air Nozzles 541-543 544 544 545 Inflating Guns Sodablasters & Accessories 600 Series Blow Gun System Pistol Air 545 546 547 548-549 Blow Pen Blow Gun Nozzles

More information

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv) Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented

More information

Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)

Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv) Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to 1.001 Cv) Order code BM-02-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented

More information

Series P directly operated solenoid valves

Series P directly operated solenoid valves > Series P solenoid valves CATALOGUE > Release 8.7 Series P directly operated solenoid valves 3/-way NC and NO. The solenoid valves can be mounted on a single base (with M5 ports) as well as on manifolds

More information

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K 5 08 25-ZK2 12 0 08 q w e r t y u i Remains blank when option is not selected.

More information

Mega Series. gas service carts L170R01 / L280R.. / L550R.. Maintenance devices for large and extra large gas compartments L170R01 / L280R.. / L550R..

Mega Series. gas service carts L170R01 / L280R.. / L550R.. Maintenance devices for large and extra large gas compartments L170R01 / L280R.. / L550R.. s Mega Series Maintenance devices for large and extra large gas compartments These service carts are our most powerful devices and guarantee quick maintenance of gas compartments. Thanks to the state-of-the-art

More information

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C Technical details Temperature range Medium -0 C... +50 C Filtered, oil-free and dried compressed air according to ISO 857-:00, Class 7::, instrument air, free of aggressive additives. Alternatively the

More information

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv) Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented

More information

SBM TECHNOLOGY PET Blow Valve Block

SBM TECHNOLOGY PET Blow Valve Block Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)

More information

GROUP 3B CLEANER AIR SYSTEM CONTENTS

GROUP 3B CLEANER AIR SYSTEM CONTENTS 3B-0 GROUP 3B CLEANER AIR SYSTEM CONTENTS SECTION 0 GENERAL 1 2. Removal and Installation 3 3 SECTION 1 SUB TANK 2 2-2 Installation 3 2 2-3 Inspection and Maintenance 3 2. Removal and Installation 2 9

More information

Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off

Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off Fastvac Mini Series: VP01QR-60 VP01QR-60H/24vDC Standard

More information

Pneumatics. Switching, automation systems, directional control in industrial and explosive atmospheres. Overview. b Switching.

Pneumatics. Switching, automation systems, directional control in industrial and explosive atmospheres. Overview. b Switching. Pneumatics Switching, automation systems, directional control in industrial and explosive atmospheres Overview b Switching b Control systems b Directional control Overview Pneumatics Contents b Presentation

More information

2/2 Pressure operated valves

2/2 Pressure operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54

More information

Prodigy HDLV System Troubleshooting - Generation III

Prodigy HDLV System Troubleshooting - Generation III Prodigy HDLV System Troubleshooting - Generation III Instruction Sheet P/N 1081071-05 Use the procedures listed in this document to isolate and correct common problems with Prodigy HDLV Systems. Refer

More information

Operating instructions Compact ejector SCPS. Innovative Vacuum for Automation /

Operating instructions Compact ejector SCPS. Innovative Vacuum for Automation / #NP#_ TU5 da8iwf P0rJU8 bmzv NU2v dy9 KkQdlWwYmyERixTbGsayVG9iH+r T3tzT+2FF8 G9+H cez7uoykiajmjm NWsBBMgA o4ynmsmkzie QZ KScUhxnKZhRHE YROA0 cize KYdcWX0VRCi KM XJcM hrfiizqtrycasjrpl U5Iduaem9r 1frC6K+7fbF9V82

More information

MACH 16 VALVES DISTRIBUTORS

MACH 16 VALVES DISTRIBUTORS MACH 16 VALVES Available in size 1/8 only, versions 5/2 and 5/3 and with pneumatic and solenoid actuation. The mach 16 valve is a typical small size valve, only 16 mm wide, with excellent performance 750

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 Description: The EDS 3000 is a compact, electronic pressure switch with integral digital display. The unit can have one or two switching outputs, and there is the option of an additional analogue output

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly

More information

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic Contents Description Page Pressure switches, pneumatic, with plug 50 Pressure switches, pneumatic, with flat pins 51 Pressure switches, pneumatic 52 55 with internal thread with flange connection Pressure

More information