Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer
|
|
- Hubert Poole
- 6 years ago
- Views:
Transcription
1 Type Ejector Ambient temperature min./max. + C / + C Medium temperature min./max. + C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed air mg/m³ - mg/m³ Protection class:with electrical connector IP4 Display LED 7 DC operating voltage 4 V Voltage tolerance DC - % / +% Status display LED Power.3 W consumption Solenoid valve Materials: Housing Seal Nozzle Release ring Silencers Polyamide, fiber-glass reinforced Acrylonitrile Butadiene Rubber Aluminum Polyamide Polyethylene Technical Remarks Note: All data refers to an ambient pressure of,3 bar and an ambient temperature of C. The pressure dew point must be at least C under ambient and medium temperature and may not exceed 3 C. Type Nozzle Ø Compressed air connection Vacuum connection+ Max. vacuum level at p.opt Max. suction capacity Part No. 3(R) (P) 3 (R) (V) (V) [mm] [%] [l/min] EBS-ET--NC R4746 EBS-ET-7-NC.7 Ø 4 Ø R4746 EBS-ET--NO 86 3 R47463 EBS-ET--NO. Ø 6 Ø R47464 (P) EBS-ET--NO 86 3 R4746 EBS-ET--NO. Ø 8 Ø 84 3 R47466 Part No. Air consumption at p.opt. Weight Fig. [l/min] [db] [db] [kg] R R Fig. R R Fig. NC = ejector line closed without current NO = ejector suction line open without current p.opt. = optimum working pressure Pneumatics catalog, online PDF, as of 6--9, AVENTICS S.à r.l., subject to change
2 Gripper and vacuum technology Vacuum generators Part No. Air consumption at p.opt. Weight Fig. [l/min] [db] [db] [kg] R Fig. 3 R NC = ejector line closed without current NO = ejector suction line open without current p.opt. = optimum working pressure Vacuum p depending on working pressure p 9 p [%] = Ø nozzle. mm = Ø nozzle.7 mm, 3 3, 4 4,,4 6 p [bar] p [%] = Ø nozzle. mm = Ø nozzle. mm, 3 3, 4 4,, 6 p [bar] 74 Pneumatics catalog, online PDF, as of 6--9, AVENTICS S.à r.l., subject to change
3 3 = Ø nozzle. mm = Ø nozzle. mm 7396 Suction capacity qs depending on working pressure p 8 q [l/min] s = Ø nozzle. mm = Ø nozzle.7 mm 6, 3 3, 4 4,,4 6 p [bar] 74 8 q [l/min] s = Ø nozzle. mm = Ø nozzle. mm, 3 3, 4 4,, 6 p [bar] 74 Pneumatics catalog, online PDF, as of 6--9, AVENTICS S.à r.l., subject to change
4 4 Gripper and vacuum technology Vacuum generators = Ø nozzle. mm = Ø nozzle. mm 7397 Evacuation time te depending on vacuum p for l volume (with optimal operating pressure popt) 3 t [s/l] E = Ø nozzle. mm = Ø nozzle.7 mm p [%] t [s/l] E = Ø nozzle. mm = Ø nozzle. mm P [%] 74 Pneumatics catalog, online PDF, as of 6--9, AVENTICS S.à r.l., subject to change
5 = Ø nozzle. mm = Ø nozzle. mm 7398 Air consumption qv depending on working pressure p 3 q [l/min] v 3 = Ø nozzle. mm = Ø nozzle.7 mm, 3 3, 4 4,,4 6 p [bar] q [l/min] s , 3 3, 4 4,, 6 p [bar] 743 = Ø nozzle. mm = Ø nozzle. mm Pneumatics catalog, online PDF, as of 6--9, AVENTICS S.à r.l., subject to change
6 6 Gripper and vacuum technology Vacuum generators 4 q [l/min] v 3 3 = Ø nozzle. mm = Ø nozzle. mm, 3 3, 4 4,,, 6 p [bar] 7399 Fig. Ø4 M Ø , 4, , 8 4 3,,, 6,8 4 Solenoid valve for vacuum ON/OFF Release valve from memory 738 Pneumatics catalog, online PDF, as of 6--9, AVENTICS S.à r.l., subject to change
7 7 Fig. Ø 8 G/8 3,6 6,, 8,4 43,3, 4 4, 8 49, , 9, Solenoid valve for vacuum ON/OFF Solenoid valve for release pulse Fig ,4 G3/8 8 4, 4, 86, 74, , 6 76 Solenoid valve for vacuum ON/OFF Solenoid valve for release pulse 7387 Pneumatics catalog, online PDF, as of 6--9, AVENTICS S.à r.l., subject to change
Ejector, Series EBS Thread connection pneumatic control, T-design with silencer
Type Ejector Ambient temperature min./max. +0 C / + C Medium temperature min./max. +0 C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed
More informationE/P pressure regulator, Series ED07 Qn= 1300 l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M12, 5-pin
Pressure regulators E/P pressure regulators E/P pressure regulator, Series ED7 Qn= l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M, Version Poppet valve Control
More informationMounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217
1 00137795 Version Spool valve, zero overlap Sealing principle Soft sealing Mounting on manifold strip P-strip Working pressure min./max. See table below Control pressure See table below min./max. Ambient
More informationFlow and check valves Logic valves Logic valves (AND/OR) Brochure
Flow and check valves Logic valves Brochure 2 Flow and check valves Logic valves Shuttle valve (OR) Qn = 80 l/min Plate valve with pipe connection Compressed air connection input: Ø 4 compressed air connection
More informationPressure regulators E/P pressure regulators Series EV04. Brochure
Pressure regulators E/P pressure regulators Brochure Pressure regulators E/P pressure regulators E/P pressure regulator, Qn= 50 l/min Compressed air connection output: G /8 Electr. connection: Plug, EN
More informationPressure regulators E/P pressure regulators Series EV07. Brochure
Pressure regulators E/P pressure regulators Series EV07 Brochure 2 Pressure regulators E/P pressure regulators Series EV07 Qn= 800 l/min Compressed air connection output: G 1/4 Electr. connection: Plug,
More informationMax. particle size 50 µm Max. oil content of compressed air
1 Version Poppet valve Control Analog Certificates CE declaration of conformity Ambient temperature min./max. +0 C / +70 C Medium temperature min./max. +0 C / +70 C Medium Compressed air Max. particle
More informationFlow and check valves Logic valves Pneumatic counters. Brochure
Flow and check valves Logic valves Pneumatic counters Brochure 2 Flow and check valves Logic valves Pneumatic counters Pneumatic presetting counter (add) 5-digit, digits Compressed air connection input:
More informationMax. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption
Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display
More informationMax. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption
Operating pressure: -4.5-74 psi electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display Units displayed Switching logic Ambient
More informationPressure regulators E/P pressure regulators Series ED05. Brochure
Series ED05 Brochure Series ED05 Qn= 000 l/min Compressed air connection output: G /4 Electr. connection: via signal connection Signal connection: input and output, Plug, M, 5-pin 4 Qn= 000 l/min Compressed
More informationMax. particle size 5 µm. Pressure for determining piston forces Repetitive precision. Polyurethane
Piston rod cylinders Guide cylinders 1 Ambient temperature min./max. +0 C / +60 C edium Compressed air ax. particle size 5 µm Oil content of compressed air 0 mg/m³ - 1 mg/m³ Pressure for determining piston
More informationDirectional valves Mechanically operated Series CD07. Brochure
Series CD07 InduParts Pneumatics B.V.B.A. Sint-Jorisstraat 40 B-8800 ROESELARE BELGIUM Tel. + (0)5 58 88 Fax. + (0)5 58 98 info@induparts.com www.induparts.com Brochure Bosch Rexroth AG Pneumatics Series
More informationPressure regulators E/P pressure regulators Series ED02. Brochure
Pressure regulators E/P pressure regulators Series ED0 Brochure Pressure regulators E/P pressure regulators Series ED0 E/P pressure regulator, Series ED0 Qn= 10 l/min compressed air connection output:
More informationDirectional valves Electrically operated CL03 series-ev. Brochure
CL03 series-ev Brochure 2 Rexroth Pneumatics CL03 series-ev Qn = 700 l/min valve width: 16 mm NO/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 3 Qn = 700 l/min
More informationMax. particle size 50 µm
00123883 Version Poppet ale Control Analog Certificates CE declaration of conformity Ambient temperature min./max. +0 C / +50 C Medium temperature min./max. +0 C / +50 C Medium Compressed air Max. particle
More informationMax. oil content of compressed air
1 Version Control Certificates Ambient temperature min./max. Medium temperature min./max. Medium Poppet valve Analog CE declaration of conformity +32 F / +15 F +32 F / +15 F Compressed air 0012533 Max.
More informationDirectional valves Pneumatically operated, according to standard ISO , 18 mm, CD02-AL series. Brochure
Directional valves Pneumatically operated, according to standard Brochure 2 Directional valves Pneumatically operated, according to standard 5/2-directional valve, Series CD02-AL Qn = 450 l/min plate connection
More informationNumber of fingers 2. Max. particle size 5 µm. Pressure for determining forces
Bosch Rexroth AG Pneumatics Version Parallel Number of fingers 2 Grip tolerance 0,02 mm Lubrication gripping elements Lubricated for life 00117208 Ambient temperature min./max. +5 C / +60 C Medium Compressed
More informationDirectional valves Mechanically operated Series AP - inch. Brochure
Directional valves Mechanically operated Brochure 2 Directional valves Mechanically operated Qn= 150-250 l/min pipe connection compressed air connection output: 1/8-27 NPTF 3 Actuating controls for AP/ST
More informationShort-stroke cylinder, Series SSI Ports: M5 - G 3/8 double-acting with magnetic piston Cushioning: elastic Piston rod: Internal thread
Ports: - G 3/8 double-acting with magnetic piston Cushioning: elastic Piston rod: Internal thread 1 Standards ISO 15524 Compressed air connection Internal thread Ambient temperature min./max. - C / +80
More information5/2-way valve, Series ST Qn= 280 l/min pipe connection compressed air connection output: G 1/8 with spring return
00108065 Version Spool valve not lockable Sealing principle metal/metal sealing Working pressure min./max. -0.95 bar / 10 bar Ambient temperature min./max. -15 C / +80 C Medium temperature min./max. -15
More informationDirectional valves Pneumatically operated Series 740. Brochure
Series 740 Brochure Bosch Rexroth AG Pneumatics Series 740 Accessories 5/2-way valve, Series 740 Qn = 700-950 l/min pipe connection compressed air connection output: Ø 8x1 - Ø 10x1 Can be assembled into
More informationDirectional valves Mechanically operated Series AP. Brochure
Series AP InduParts Pneumatics B.V.B.A. Sint-Jorisstraat 40 B-8800 ROESELARE BELGIUM Tel. +31 (0)51 22 58 88 Fax. +31 (0)51 22 58 98 info@induparts.com www.induparts.com Brochure Bosch Rexroth AG Pneumatics
More informationMulti-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications
Multi-Stage Ejectors Suction rate from 332 l/min to 2,370 l/min Suitability for Industry-Specific Applications Applications Multi-stage ejector for handling of cardboard, packing materials, insulating
More informationShort-stroke cylinder, Series KHZ Ports: M5 - G 1/4 Single-acting, retracted without pressure Cushioning: elastic Piston rod: Internal thread
: - G 1/4 Single-acting, retracted without pressure Cushioning: elastic Piston rod: Internal 1 Compressed air connection Internal Ambient temperature min./max. -25 C / +80 C Medium temperature min./max.
More informationWith Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-
Features and Benefits Solenoid-Actuated Vacuum Generators Types VADM-... / VADMI-... l Integral Filter, Silencer, Manual Override l Integral Solenoid Valve for Controlling Air Supply l Vacuum Range up
More informationStandards ISO Max. particle size 50 µm. Pressure for determining piston forces. Materials: Polyurethane
Ports: - double-acting with magnetic piston Cushioning: elastic Piston rod: external thread 1 Standards ISO 21287 Compressed air connection Internal thread Working pressure min./max. 1 bar / 10 bar Ambient
More informationValve terminal systems Valve terminal systems Series TC08. Brochure
Series TC08 Brochure Bosch Rexroth AG Pneumatics Series TC08 Valve terminal systems Valve terminal system, Series TC08 Qn max. = 800 l/min; single plug-in wiring; Electr. connection: Plug M8 / plug, form
More informationValve terminal systems Valve terminal systems Series TC15. Brochure
Series TC15 Brochure Bosch Rexroth AG Pneumatics Series TC15 Valve terminal systems Valve terminal system, Series TC15 Qn max. = 1500 l/min; single plug-in wiring; Electr. connection: plug, form C / Plug
More informationStandards NFE Max. particle size 50 µm. Pressure for determining piston forces. Materials:
Piston rod cylinders Short-stroke and compact cylinders 1 Standards NFE 49004 Compressed air connection Internal thread Ambient temperature min./max. -20 C / +80 C Medium temperature min./max. -20 C /
More informationPreparation of compressed air Supplementary products Pressure gauge. Brochure
Preparation of compressed air Pressure gauge Brochure 2 Preparation of compressed air Pressure gauge Pressure gauge, Series P1-SNL Front port Background color: Scale color: reen / White Viewing window:
More informationStandards NFE Max. particle size 50 µm. Pressure for determining piston forces. Materials:
Ports: - double-acting with magnetic piston Cushioning: elastic Piston rod: Internal thread, 1 Standards NFE 49004 Compressed air connection Internal thread Ambient temperature min./max. -20 C / +80 C
More informationSensor technologies Pressure sensors Series PE5. Brochure
Sensor technologies Pressure sensors Series PE5 Brochure 2 Sensor technologies Pressure sensors Series PE5 Operating pressure: -4.5-74 electronic Output signal digital: 2 outputs - output IO-Link electr.
More informationMax. particle size 5 µm. Pressure for determining piston forces. Materials:
Rodless cylinders Rodless cylinder 1 Working pressure min./max. 2 bar / 8 bar Ambient temperature min./max. -10 C / +60 C Medium Compressed air Max. particle size 5 µm Oil content of compressed air 0 mg/m³
More informationStandards ISO Max. particle size 50 µm. Pressure for determining piston forces 6 bar. Materials:
Bosch Rexroth AG Pneumatics Ø - 100 mm Ports: M5 - double-acting with magnetic piston cushioning: elastic piston rod: Standards ISO 21287 Compressed air connection internal thread 00119673 Working pressure
More informationGSW-V. Application example. Special Gripper Vacuum Gripper. Weight 0.12 kg 0.39 kg. Clamping diameter 20 mm 32 mm
GSW-V Suction pad diameter 30 mm 125 mm Clamping diameter 20 mm 32 mm Weight 0.12 kg 0.39 kg Gripping force 55 N 980 N Workpiece weight 0.28 kg 4.9 kg Application example Handling of gears in a milling
More informationVacuum generators 1.1. High vacuum levels of up to 93% Easy connection of holders and suction cups. Lightweight and compact design.
High vacuum levels of up to 93% Easy connection of holders and suction cups Lightweight and compact design No wearing parts Long service life Vacuum monitoring with vacuum switch 2005/07 Subject to change
More informationRotary actuators Rack-and-pinion gears series TRR. Brochure
series TRR Brochure 2 Bosch Rexroth AG Pneumatics series TRR Rotary cylinder, Series TRR angle of rotation: 0-60 Ø2-00 mm with magnetic piston double piston with rack cushioning: pneumatically, adjustable
More information-Q- Temperature range C. -L- Operating pressure bar. Vacuum filters ESF Technical data. Function
Vacuum filters Vacuum filters ESF Function -Q- Temperature range 0 +60 C -L- Operating pressure 0.95 +4 bar Accessory for the suction gripper ESG, mounted between suction cup holder and suction cup with
More informationVSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter
Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features
More informationSeries BCP standard version double Stroke: mm
1 ersion Bellow actuator with cover Functional principle Single-acting, retracted without pressure Permissible angle of tilt max. Working pressure min./max. bar / bar Ambient temperature min./max. - /
More informationRodless cylinders Rodless cylinders Series RTC. Brochure
Series RTC Brochure Bosch Rexroth AG Pneumatics Series RTC Rodless cylinder, Series RTC-BV Ø 16-80 mm; double-acting; with magnetic piston; integrated guide; Basic Version; cushioning: pneumatic, adjustable
More informationVacuum generation Compact ejectors
Energy saving function by integrated pressure control saves up to 5 % of energy q = Vacuum connection z = Compressed air connection Product notes s = Exhaust outlet Check valve with wire mesh to keep out
More information0322, 0324, Pilot Solenoid Valve, Plastic
Pilot Solenoid Valve, Plastic Construction The directly controlled GEMÜ 3/2-way pilot solenoid valve consists of an epoxy encapsulated detachable coil and a plastic body. The electrical connection is made
More informationMax. particle size 5 µm. Pressure for determining piston forces. Materials:
1 Working pressure min./max. 2 bar / 8 bar Ambient temperature min./max. -10 C / +60 C Medium Compressed air Max. particle size 5 µm Oil content of compressed air 0 mg/m³ - 1 mg/m³ Pressure for determining
More informationVacuum generators Key features
Vacuum generators Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The product families
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More informationVacuum generators OVEM
Key features At a glance Accelerated vacuum reduction for safe placement of the workpiece by means of integrated solenoid valve for controlling the ejector pulse Central electrical connection via M12 plug
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview Air preparation unit three-piece 8 11 12 16, 17 Air preparation unit two piece 8 11 12 16, 17 Air preparation Filter-regulator
More informationLS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm
Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic
More informationCylinder Accessories Piston rod mountings, series CM2 Rod clevises. Brochure
Cylinder Accessories Piston rod mountings, series 2 Rod clevises Brochure 2 Cylinder Accessories Piston rod mountings, series 2 Rod clevises Rod clevis with lock washer, Series AP2 Stainless steel 3 Rod
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 1507-18 mm - pad mounting body M1 connection x/ - 5/ - 5/ Series 50 ISO 1507- (18 mm) FEATURES M1 connection with electrical
More informationSERIES RTC RODLESS CYLINDERS PNEUMATIC SHUTTLE TYPE
SERIES RTC RODLESS CYLINDERS PNEUMATIC SHUTTLE TYPE Series RTC Rodless Cylinder Pneumatic automation building block Series RTC (Rodless Thrust Cylinder)-High performance shuttle type rodless cylinders
More informationControl unit for valves with inflatable sealing system
Control unit for valves with inflatable sealing system Type ICS A model from the system -vacotrol Shut-off valves are used in transport equipment for bulk powder and granulate, whose shut-off mechanism
More information1 0,1 0,1-70 0, , , , Cylinder bore <
Working medium, air quality Working medium: Dry, filtered compressed air to ISO 83-1 class 3.4.3. Recommended air quality for valves For best possible service life and trouble free operation, ISO 83-1
More informationRodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure
Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR Brochure 2 Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR single Stroke: 94-135 mm 3 double
More informationAir-Operated Double-Diaphragm. High Purity PTFE Pumps
Air-Operated Double-Diaphragm High Purity PTFE Pumps ULTRA High-Purity Series Ultra-High Purity Series was designed specifically for the Semiconductor Yamada s advantages come from years process of experience
More informationVacuum generators OVEM
Key features At a glance Rapid purging of vacuum for safe placement of the workpiece by means of an integrated solenoid valve for controlling the ejector pulse Central electrical connection via an M12
More information3/2-way Solenoid Valve for pneumatics
656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511
More informationnickel-plated brass - PBT technopolymer HNBR, FKM stainless steel
CATALOGUE > Release 8.8 > Series A solenoid valves Series A directly operated solenoid valves /-way - Normally Closed (NC) and Normally Open (NO) 3/-way - Normally Closed (NC) and Normally Open (NO)»»
More informationSeries PD directly operated solenoid valves
> Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current
More information3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics
65 /-way and x /-way Rocker Solenoid Valve for pneumatics Type 65 can be combined with... Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Fast response times Space
More informationnickel-plated brass - PBT technopolymer HNBR, FKM stainless steel
CATALOGUE > Release 8.7 > Series A solenoid valves Series A directly operated solenoid valves /-way, 3/-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 - G1/8 - R1/8 - cartridge ø4
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 8 11 12 16, 17 unit two-piece 8 11 12 16, 17 Filter-regulator 8 11 13 16, 17 Filter-water-separator
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126
System 6 Electropneumatic Converter for Direct Current Signals i/p Converter Type 66 Application Devices used to convert a direct current signal into a pneumatic signal for measurement and control. Especially
More informationMulti Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide
Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide 3/2 and 5/2 Way Valves Optimum system solutions due to high level of modularity Maintenance free and little wear due to high level
More information3/2-way Rocker Solenoid Valve for pneumatic systems
3/-way Rocker Solenoid Valve for pneumatic systems EEx ia versions Direct-acting High cycling rate Reduced power consumption Type 6104 can be combined with... Sub-base connection Approvals: Type 654 Servo-assisted
More informationIntelligent Positioner
Intelligent Positioner Construction The GEMÜ 1 µpos is a digital electro-pneumatic positioner for process valve control. Designed for simple, safe and quick use with valves with strokes < mm. The positioner,
More informationExhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage.
Exhaust Cleaner for Clean oom Series ohs An exhaust cleaner that can be used inside a clean room How to Order 0 0 Exhaust air cleanliness: Equivalent to ISO Class (Class 0 ed.std.0) (Consult SMC in advance,
More informationSeries 581 ISO Pneumatic Directional Control Valves
Series 581 ISO 5599-1 Pneumatic Directional Control Valves Series 581 Pneumatic Valves 01_1 st Headline_36 pt/14.4 mm 4-Way ISO Directional Control second line Series 581 - A complete series of standardized
More informationVacuum Ejector with Solid State Timer
Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON
More informationSimple venturis, series GVP
Simple venturis, series GVP 5-bar compressed air network 45 13 5 35 L1 Exhaust D1 L 1/4 gas, 6x8 quick-connect or 4x6 quick-connect D 30 Connection for options 6 Vacuum 1/ gas Vacuum generators in series
More informationVACUUM PUMP P5010. Profit from new vacuum technology
VACUUM PUMP P5010 COAX THE NEXT DIMENSION IN VACUUM TECHNOLOGY Profit from new vacuum technology Patented COAX push-in technology Efficient use of energy Outstanding performance Slim and modular design
More informationType 3379 Pneumatic Actuator. Mounting and Operating Instructions EB 8315 EN
Type 3379 Pneumatic Actuator Mounting and Operating Instructions EB 8315 EN Edition October 2014 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result in death or serious
More informationBlowers. SILENCE 54 ASO 55 ROBUST 56 AIRPACK 57 MONO 58 Frequency Converter 59 Accessories General Catalog Process Heat
52 SILENCE 54 ASO 55 ROBUST 56 AIRPACK 57 MONO 58 Frequency Converter 59 Accessories 6 www.leister.com General Catalog Process Heat 53 SILENCE: The quieter option. No blower no air! In industrial processes
More informationSeries PD directly operated solenoid valves
> Series PD solenoid valves CATALOGUE > Release 8.7 Series PD directly operated solenoid valves New /-way Normally Closed (NC) Note: all Series PD /-way solenoid valves are basically in DC. To operate
More informationGWS. Application example. Tool Changing Gripper Change System. Handling weight up to 170 kg. Moment load M x up to 400 Nm
GWS Sizes 064.. 125 Handling weight up to 170 kg Moment load M x up to 400 Nm Moment load M y up to 400 Nm Moment load M z up to 600 Nm Application example Replacing and placing tools in a gripper changing
More informationISO Cylinders Compact Cylinders TC08 Series Plastic Finger Tight Fittings
ISO 632 Cylinders ISO 15552 Cylinders Compact Cylinders TC08 Series Pilot Valves 207-208 209-212 213-21 215 TC15 Series Pilot Valves TC08 Series Solenoid Valves CD7 Series Solenoid Valves CD12 Series Solenoid
More informationKARL SCHNELL GRINDER SPECIFICATION: KS Process Automat B 22 Type l
KARL SCHNELL GRINDER SPECIFICATION: KS Process Automat B 22 Type 250 300l Execution - total volume mixer bowl approx. 380 l, nominal volume approx. 300 l - stationary design, with four height adjustable
More informationSystem 6. ü ( System 6
System 6 ü www.nassmagnet.com ( +9 511 676-0 System 6 The name System 6 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More informationSubject: Pneumatic Training Kit with portable Air Compressor
MSME TOOL ROOM: HYDERABAD (CENTRAL INSTITUTE OF TOOL DESIGN) Balanagar, Hyderabad 500 037 TEL.NO.23772747, 23776168 FAX No.0-4023772658 E-mail:citdpurchase@citdindia.org Visit us: www.citdindia.org. TENDER
More informationElectrically operated spool valve. The manual override is detent and is operated by screw driver.
Valves > electrically operated valves > Series M-07 Technical details Connection G1/ Nominal size Temperature range Medium Series M-07 page Materials 9 mm -10 C... +70 C Filtered, oil-free and dried compressed
More informationNozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features
ariety of modularized units enable selections of integrated type ejector units suitable for the application. K eries Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2 ZM Q G Y H U B C K KM J JM X XM Features acuum
More informationSolenoid valves VOVG Product range overview
Valve series VOVG Product range overview Function Symbol Version Normally Voltage [V DC] Page/ open closed 5 12 2 Internet /2-way valve In-line valve 8/vovg Semi in-line valve Sub-base valve 5/2-way valve
More informationIntelligent Positioner
Intelligent Positioner Construction The GEMÜ epos digital electro-pneumatic positioner detects the valve position via its external LongLife travel sensor. It has a solid housing with protected operating
More informationStandard Valves. Vacuum Technology.
Standard Valves Vacuum Technology. Our company Founded in 1970 by Ernst- Günter Meßner, our company started by dealing in industrial commodities. Shortly thereafter, we took the step towards our own production
More informationTopControl Continuous
860 Electropneumatic positioner for pneumatically actuated control valves Type 860 can be combined with... Type 7 Type 70 Types 70/7/7K Type 800 Piston-controlled globe valve Piston-controlled angle seat
More informationVacuum pumps/generators Small
picompact10 Ejector with COAX patented technology. Reduced air-consumption with 30-50% compared to other ejector technologies. Easy to optimize vacuum performance with a varied selection of micro multi-stage
More informationOn-off Valves MS-EE, Inch Series Overview
On-off Valves MS-EE, Inch Series Overview Electrically actuated on-off valve for pressurising and exhausting pneumatic systems Choice of three voltage ranges 2 sizes: MS4 grid dimension.6 in, MS6 grid
More informationSeries ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.
Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum
More informationCost effective. Productive. Compliant. GSW-M Magnetic Gripper
Cost effective. Productive. Compliant. Magnetic Gripper Vacuum gripper for spindle interfaces is ideal for handling flat components. Field of Application Unit for automatic loading and unloading of machining
More informationSeries ICS and ICL Pneumatic Cylinders. Corrosion resistant stainless steel and aluminum cylinders
Series ICS and ICL Pneumatic Cylinders Corrosion resistant stainless steel and aluminum cylinders Series ICS and ICL cylinders New generation of stainless steel and clean line cylinders. Series ICS from
More informationSeries AN /Series AMC
s/exhaust Cleaner / Noise reduction Nominal filtration rating (eference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0-2 Compact type
More informationProduct. Information. A.u.K. Müller. Flow meter turbine, with shut-off device. Series Characteristics. Applications.
Series 7.007 Solenoid valves Control valves Special valves and systems A. u. K. Müller GmbH & Co. KG Dresdener Str. 6 D-40595 Düsseldorf/Germany Tel.: +49(0)-79-0 Fax: +49(0)-79-8 e-mail: info@akmueller.de
More informationVacuum generators OVEM
Key features At a glance Rapid purging of vacuum for safe placement of the workpiece by means of an integrated solenoid valve for controlling the ejector pulse Central electrical connection via an M12
More informationES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min
Suction Filters ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp. upstream
More informationOnline data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES
Online data sheet i15-em03 Lock i15 Lock i15-em03 Lock i15 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i15-em03 Lock 6034028 The actuator has to be ordered separately.
More information2/2 Pressure operated valves
Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54
More informationSolenoid valves VUVB/valve terminals VTUB, NPT
Solenoid valves VUVB/valve terminals VTUB, NPT Solenoid valves VUVB/valve terminals VTUB, NPT Key features Innovative Versatile Reliable Easy to mount Valve terminal for a wide range of pneumatic applications
More information