OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D"

Transcription

1 Nordson Corporation OPERATOR S CARD P/N D Select Series H-440 Hot Melt Dispensing Guns Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: Series H-440 guns are designed for use with Nordson equipment. When using the guns with non-nordson equipment, follow the safety information and operating procedures in your equipment-specific manuals. Pay special attention to the procedures for electrical grounding, gun air pressure adjustment, system hydraulic pressure adjustment, and relieving hydraulic pressure. WARNING: Risk of personal injury. If you remove the preinstalled solenoid valve, correct reinstallation is required to prevent normally open gun operation. A normally open gun will dispense adhesive uncontrollably until the primary air supply is interrupted. WARNING: Risk of equipment damage. Series H-440 gun modules operate as air-open, air-close valves. The loss or elimination of air pressure to the gun solenoid valve without a corresponding reduction in hydraulic pressure may cause the gun modules to remain open. Description Nordson Series H-440 guns are used to apply thermoplastic hot melt materials to a product. Polyurethane-reactive (PUR) and high-temperature polyamide adhesives can negatively affect gun performance and durability. H-440 gun modules are designed for high speeds and extended service life. An H-440 gun module can exceed 4,500 cycles per minute and provide up to twice the service life of a Nordson Series H-200 gun module. H-440 gun modules provide uniform bead deposition and improved cutoff in aggressive or hard-to-dispense adhesives. H-440 gun modules for ITW Dynatec, Robatech, and KB Series hot melt systems are heated by replaceable heater elements that are controlled by a Pt-100 platinum temperature sensor (ITW Dynatec) or a negative temperature coefficient (NTC) thermistor (Robatech). A variety of nozzle sizes may be used with H-440 guns ÂÂÂ Fig. 1 H-440 Gun Components 1. Gun air pressure 5. Mounting bracket regulator 6. Gun module 2. Air supply line 7. Gun manifold 3. Silencer 8. Hose 4. Solenoid valve 9. Gun cordset A Issued 3/ H440-MA-02

2 Specifications Item Specification Note Operating temperature 232 C (450 F) maximum Operating hydraulic pressure bar (1,500 psi) maximum A Operating air pressure bar (50-80 psi) B Operating speed Exceeds 4,500 cycles per minute Nozzles Series 237 XXX, 238 XXX, right-angle, and Saturn nozzles C Electrical service 240 V AC, 50/60 Hz 200 V AC, 50/60 Hz (for low-voltage areas) Solenoid valve power supply 24 V DC only D Approvals and certifications CE/UL/CUL/TUV NOTE A: The maximum operating hydraulic pressure is 70 bar (1,000 psi). B: Use dry, regulated, unlubricated air for consistent gun operation. C: Series H-440 guns use the same nozzles as Series H-200 guns. D: Contact Nordson if you wish to use an alternate power supply. Installation Guidelines Mount the guns so the nozzles are no more than 13 mm (0.5 in.) from the product. Protect the guns from vibration and secure them so they will not change position during application. When installing or replacing the solenoid valve, make sure valve port 4 is connected to the closed gun manifold port and valve port 2 is connected to the open gun manifold port. If you need to use extra fittings to connect the hose to the gun, contact Nordson to order optional straight, 45, and 90 fittings. Use one of the following power supplies for the solenoid valve: Insulate gun-to-hose joints. Use Nordson precision nozzles. Contact Nordson to order nozzles. - In North America, use a National Electrical Code (NEC) Class 2 or equivalent power supply. Make sure the gun air pressure regulator is capable of providing a minimum of 3.4 bar (50 psi) to the solenoid valve. If you change the preinstalled Nordson solenoid valve, make sure the new valve has the same center-line dimensions and port operation as the Nordson valve. - In Europe, use a Protective Extra Low Voltage (PELV) or Safety Extra Low Voltage (SELV) power supply. This supply must provide 24 V DC, have an output limited to 8 A, and not be capable of providing more than 240 V AC under any fault condition. The supply must be certified for use in the country of installation. Setup for Robatech Guns To ensure proper temperature-control sensing on Robatech guns, set the temperature-compensation factor to 7.5. For information on how to set the temperature-compensation factor, refer to your Robatech hot melt unit manual. 42-H440-MA-02 2 Issued 3/03

3 Parts To order parts, contact the Nordson Customer Service Center or your local Nordson representative at Use the following parts lists to describe and locate parts correctly. Gun Cordset and Sensor Item Dynamini/ melt Gun Dynapro/ plus Gun Robatech Gun KB Series Gun Description Quantity Note Cordset, gun, 22 in Cordset, gun, 24 in. 1 A 1 A NOTE A: Includes sensor or thermistor. To replace the sensor or thermistor, order a replacement cordset. Gun Heater Dynamini/ melt Gun Dynapro/ plus Gun Robatech Gun KB Series Gun Description Heater Part Number H-441, 240 V AC Note H-442, 240 V AC, 2.31 in. center-line H-442, 240 V AC, 0.88 in. center-line, low-profile A, B H-444, 240 V AC, 0.88 in. center-line H-444, 240 V AC, 0.88 in. center-line, low-profile A, C NOTE A: Requires two heaters. B: Requires one (1) each of gaskets part and part C: Requires one (1) each of gaskets part and part HEATER HEATER 2 SENSOR KB SERIES CORDSET PINS ROBATECH GUN CORDSET PINS Fig. 2 Series H-440 Gun Cordset and Heater 1. Cordset with sensor/thermistor 2. Heater ITW DYNATEC GUN CORDSET PINS A Issued 3/ H440-MA-02

4 Parts (contd) Gun Module and Solenoid Valve Item KB Series Gun Description Quantity Note Gun module, H-440, air-open, air-close 1 A NS Gun module O-ring, 0.28 ID x 0.70 in. 3 B Solenoid valve, 1.00 Cv, 24 V DC, 1 / 4 NPT, quick-disconnect, light, piloted 1 NOTE Compression nut, air supply tube 4 C Muffler, air, 1 / 8 NPT 2 D Silencer, 1 / 8 NPT x 2.31 in. long 2 D A: This kit includes three (3) O-rings and two screws (to attach the gun module to the gun manifold). B: This kit includes ten (10) O-rings. C: This kit includes five (5) compression nuts. D: Most guns are shipped with air mufflers that are used to reduce solenoid valve exhaust noise. If desired, you can use silencers instead of air mufflers. Silencers provide extended service life. NS: Not Shown OR 3 4 OR Â Â ÂÂÂÂ GUN CLOSED PORT GUN OPEN PORT A Fig. 3 Series H-440 Gun Module and Solenoid Valve 42-H440-MA-02 4 Issued 3/03

5 Troubleshooting Use the following table if your gun is not applying adhesive properly. Refer to your equipment-specific manuals for troubleshooting procedures for your hot melt system. Problem Possible Cause Corrective Action 1. No adhesive output from gun modules 2. Gun underheats or overheats No input power Low or no input air pressure to solenoid valve Solenoid valve malfunctioning or power supply to solenoid valve insufficient Clogged gun nozzle, module, or manifold. Failed heater Failed sensor or thermistor Make sure the gun cordset connection is tight and the solenoid valve power supply is turned on. Check the gun air pressure setting. Check the solenoid valve and the power supply to the valve. Clean the nozzle. If cleaning the nozzle does not solve the problem, replace the gun module. If that does not solve the problem, replace the gun. Replace the heater. Check the sensor or thermistor resistance. The sensor resistance should be 108 ohms at 22 C (72 F) and 165 ohms at 177 C (350 F). The thermistor resistance should be 100K ohms at 25 C (77 F) and 1000 ohms at 175 C (347 F). If the sensor or thermistor is defective, replace the cordset. Cleaning Nozzles WARNING: Risk of burns. Relieve hydrualic pressure. 1. Turn off the pump and relieve hydraulic pressure. Refer to your equipment-specific manual. 2. Place a drain pan under all guns. 6. Use a wrench to loosen the nozzles; then remove the nozzles by hand. 7. Place the nozzles in a container of Type-R cleaning fluid and heat the fluid above the adhesive s melting temperature. 3. Manually trigger the guns until they are drained of adhesive. 4. Turn off the unit. 5. Turn off the gun air supply and the solenoid valve power supply. 8. Remove the nozzles from the cleaning fluid and clean them using a pin-type probe. WARNING: Hot! Risk of burns. Wear heat-protective clothing, safety goggles, and heat-protective gloves. 9. Reinstall the nozzles on the guns and restore the system to normal operation. Issued 3/ H440-MA-02

6 Operation Startup Shutdown CAUTION: Risk of equipment damage. H-440 gun modules operate as air-open, air-close valves. Nordson Corporation recommends turning off the gun air supply during system statup to prevent unexpected pressure buildup in the gun module and manifold caused by the expansion of the cold adhesive as it melts. 1. Make sure the gun air supply is turned off. 2. Turn on the unit and allow it to reach operating temperature. Refer to your equipment-specific manual for the startup procedure. 3. Turn on the gun air supply. 4. Turn on the solenoid valve power supply, enable any triggering devices, and start the production line. Adhesive Application Adjustment To modify how adhesive is applied: Adjust the adhesive temperature. Refer to the adhesive manufacturer s data sheet. Adjust the gun distance from product. The distance should be 13 mm (0.5 in.) or less. 1. Stop the production line. WARNING: Risk of burns. Relieve hydrualic pressure. 2. Turn off the pump and relieve hydraulic pressure. Refer to your equipment-specific manual. WARNING: Hot! Risk of burns. Wear heat-protective clothing, safety goggles, and heat-protective gloves. 3. Place a drain pan under all guns. 4. Manually trigger the guns until they are drained of adhesive. 5. Turn off the unit. 6. Turn off the solenoid valve power supply. 7. Turn off the gun air supply. 8. Manually trigger the gun solenoid valves to relieve gun air pressure. Adjust the hydraulic pressure. The operating range is bar ( psi). Adjust the gun air pressure. The operating range is bar (50 80 psi). Change your nozzle selection. Â NOTE: Nordson Corporation recommends selecting a nozzle with a hole size and length that allows the guns to operate above 28 bar (400 psi). Fig. 4 Solenoid Valve Manual Trigger Location A 42-H440-MA-02 6 Issued 3/03

7 DECLARATION OF CONFORMITY (For CE-Certified Select Series H-400 Hot Melt Dispensing Guns) APPLICABLE DIRECTIVES: 73/23/EEC (Low Voltage Directive) PRINCIPLES: This product has been manufactured according to good engineering practice. This product conforms to the directive and standards described here. STANDARDS USED TO VERIFY COMPLIANCE: EN Nordson Corporation Westlake, Ohio Donald J. McLane, Senior Vice President Date: Issued 3/ H440-MA-02

8 Dynamini, Dynamelt, Dynapro, Dynaplus, and Robatech are trademarks of ITW Dynatec, Inc. Original copyright date Nordson and the Nordson logo are registered trademarks of Nordson Corporation. 42-H440-MA-02 8 Issued 3/03

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E Nordson Corporation OPERATOR S CARD P/N 32 96E Select Series H-400 Hot Melt Dispensing Guns Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection

More information

Installation Instructions for Series 3100V Low Level Indicator

Installation Instructions for Series 3100V Low Level Indicator Instruction Sheet P/N Installation Instructions for Series 3100V Low Level Indicator WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

E-200 Module Service Kit

E-200 Module Service Kit Instruction Sheet E-200 Module Service Kit 1. Introduction These instructions describe how to remove and replace the E-200 module. The instructions include the following: S S S S Safety Unit Preparation

More information

Series 3900/M Pump Retrofit Kit

Series 3900/M Pump Retrofit Kit Instruction Sheet P/N Series 900/M Pump Retrofit Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

Solenoid Valve Installation Kit

Solenoid Valve Installation Kit Instruction Sheet P/N 7 5A Solenoid Valve Installation Kit WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related

More information

Blow Off Valve Retrofit Kit

Blow Off Valve Retrofit Kit Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..

More information

Series 3000V Low Level Indicator

Series 3000V Low Level Indicator Instruction Sheet P/N 237 473A Series 3000V Low Level Indicator 1. Introduction The low level indicator sends a signal to an external device when the adhesive level in the applicator s tank is low. The

More information

Preventive Maintenance for Pail Melters

Preventive Maintenance for Pail Melters Instruction Sheet P/N Preventive Maintenance for Pail Melters 1. Introduction These procedures are recommended in addition to the standard preventive maintenance. Use them to keep yourvista controlled

More information

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01 Section 9 NOTE: This section applies to applicators with CC200 modules. 9-0 Table of Contents i Table of Contents Section 9 1. Introduction............................................... 9-1 2. Specifications.............................................

More information

Maintenance. Part A, Section 5. This section covers the following unit configurations.

Maintenance. Part A, Section 5. This section covers the following unit configurations. Part A, Section 5 This section covers the following unit configurations. Model 3100V 3400V 3830V 3860V 3890V 3930V Voltage 1, 2 Pump AC Gear (K or L) Manifold 4-Port (J)) Control Vista Standard (V) Vista

More information

Low Level Indicator. Part E, Section 1. This section covers the following unit configurations. 3500V 3700V 3800V 3900V E2EN 03 [3V LLI] 4

Low Level Indicator. Part E, Section 1. This section covers the following unit configurations. 3500V 3700V 3800V 3900V E2EN 03 [3V LLI] 4 Part E, Section 1 This section covers the following unit configurations. Model 3400V 3500V 3700V 3800V 3900V Voltage All Pump All Manifold All Control All E 1-0 E 1-1 Section E 1 WARNING: Allow only qualified

More information

Two Component Meter Cylinder Assembly Replacement

Two Component Meter Cylinder Assembly Replacement Instruction Sheet P/N Two Component Meter Cylinder Assembly Replacement WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV Generation II Pump Panel Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change

More information

Paint/Solvent/Dump Valve and Flow-Through Valve

Paint/Solvent/Dump Valve and Flow-Through Valve Instruction Sheet P/N 08573D Paint/Solvent/Dump Valve and Flow-Through Valve. Description See Figure. The paint/solvent/dump valve is a normally-closed valve that opens to trigger and/or dump coating material.

More information

Miniature Soft Seat Fluid Pressure Regulator

Miniature Soft Seat Fluid Pressure Regulator Instruction Sheet P/N 1. Description The Nordson miniature soft seat fluid pressure regulator is designed for use with hydraulic and pneumatic medias. The regulator body and wetted parts are constructed

More information

Sure Coat 90 Degree Spray Extension

Sure Coat 90 Degree Spray Extension Instruction Sheet P/N 076A Sure Coat 90 Degree Spray Extension Description The 90 Degree Spray Extension is used on Sure Coat Automatic Powder Spray Guns. It allows powder to be sprayed at right angles

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules. 9-1 Section 9 NOTE: This section applies to applicators with CF200PAD right-angle modules. Table of Contents.................................................... 9-1 Introduction................................................

More information

OPERATIONS AND SERVICE MANUAL MOD-PLUS TM DYNA BF HOT MELT ADHESIVE APPLICATOR HEADS

OPERATIONS AND SERVICE MANUAL MOD-PLUS TM DYNA BF HOT MELT ADHESIVE APPLICATOR HEADS OPERATIONS & SERVICE MANUAL #40-31 Revised 8/1/13 OPERATIONS AND SERVICE MANUAL MOD-PLUS TM DYNA BF HOT MELT ADHESIVE APPLICATOR HEADS IMPORTANT! - READ ALL INSTRUCTIONS BEFORE OPERATING THIS EQUIPMENT

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules. 9- Section 9 NOTE: This section applies to applicators with MB200 modules. Table of Contents.................................................... 9- Introduction................................................

More information

Econo-Coat Manual Powder Spray Gun

Econo-Coat Manual Powder Spray Gun Econo-Coat Manual Powder Spray Gun Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local

More information

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA Installation and Maintenance Instructions Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Pattern Air Control Kit (PACK)

Pattern Air Control Kit (PACK) Instruction Sheet P/N 044445B0 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or

More information

Nordson Airless Nozzle Tester

Nordson Airless Nozzle Tester Instruction Sheet P/N Nordson Airless Nozzle Tester. Introduction The Nordson airless nozzle tester is used to test the flow rate of flanged airless nozzles. The results of the tests can be used to determine

More information

EP-2 Three-Piston Pump

EP-2 Three-Piston Pump EP- Three-Piston Pump Customer Product Manual Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your local Nordson representative.

More information

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part B, Section 2 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, G) Manifold 4-Port (A) 6-Port (B, C) 2-Port (S, T) Vista Standard (V) B 2-0

More information

0-500 PSI Soft Seat Fluid Pressure Regulator

0-500 PSI Soft Seat Fluid Pressure Regulator Instruction Sheet P/N 0953A Description The Nordson 0-500 psi soft seat fluid pressure regulator is designed for use with nonabrasive liquid coatings. The regulator body is constructed of stainless steel

More information

Sure-Max Powder Transfer System

Sure-Max Powder Transfer System Sure-Max Powder Transfer System Customer Product Manual Issued 7/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local

More information

NRPS-100 Rotary Sieve

NRPS-100 Rotary Sieve NRPS-100 Rotary Sieve Customer Product Manual Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Air Spray Proportioning Valve

Air Spray Proportioning Valve Instruction Sheet P/N Air Spray Proportioning Valve. Installation The air spray proportioning valve provides close regulation of air spray characteristics for air spray versions of the Pro-Flo dispensing

More information

Prodigy Robot Gun. For parts and technical support, call the Finishing Customer Support Center at (800)

Prodigy Robot Gun. For parts and technical support, call the Finishing Customer Support Center at (800) Prodigy Robot Gun Customer Product Manual Issued 3/14 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change without notice. Check

More information

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6 Part B, Section 5 Model 500 Voltage, Pump Piston (E) Manifold -Port (B or C) -Port (S or T) Control MultiScan (M) 000Nordson Corporation -000 Issued /00 B 5-0 -000 Issued /00 000 Nordson Corporation B

More information

Nordson/Drexelbrook Material Level Control Kit

Nordson/Drexelbrook Material Level Control Kit Nordson/Drexelbrook Material Level Control Kit NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

RA-20 Paint/Solvent/Dump Valve

RA-20 Paint/Solvent/Dump Valve Instruction Sheet P/N 74B0 RA-0 Paint/Solvent/Dump Valve Description The paint/solvent valve is a normally closed valve used to trigger coating material. The valve may be used alone to actuate paint or

More information

8. Illustrated Parts Lists

8. Illustrated Parts Lists Hydraulics B 1-45 8. Illustrated Parts Lists To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations,

More information

E-400 Electric Gun. Product Release. August 2003

E-400 Electric Gun. Product Release. August 2003 Product Release Product The electric gun precisely dispenses bead of hot melt adhesive at exceptionally high speeds. This gun was specifically designed for use in highspeed applications requiring beads

More information

Trilogy Air Spray and LVLP Automatic Spray Guns

Trilogy Air Spray and LVLP Automatic Spray Guns Trilogy Air Spray and LVLP Automatic Spray Guns Customer Product Manual Part 1601058-03 Issued 3/14 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800)

More information

Versa-Spray II Automatic Powder Spray Gun

Versa-Spray II Automatic Powder Spray Gun Versa-Spray II Automatic Powder Spray Gun Customer Product Manual Issued /06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your

More information

8. Illustrated Parts Lists

8. Illustrated Parts Lists Hydraulics B 1-41 8. Illustrated Parts Lists To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations,

More information

Prodigy Generation II High-Capacity HDLV Powder Transfer Pump

Prodigy Generation II High-Capacity HDLV Powder Transfer Pump Prodigy Generation II High-Capacity HDLV Powder Transfer Pump Customer Product Manual Issued 0/0 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document

More information

Description. Rhino SD2/XD2 Follower Modules

Description. Rhino SD2/XD2 Follower Modules Rhino SD/XD Follower Modules Description See Figure. The follower module attaches onto the hydraulic section of the pump (). It is designed to force material out of straight-sided containers. Standard

More information

8. Illustrated Parts Lists

8. Illustrated Parts Lists Hydraulics B 1-43 8. Illustrated Parts Lists To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations,

More information

Model AD-29A Automatic Air Spray Gun and Can Marking System

Model AD-29A Automatic Air Spray Gun and Can Marking System Model AD-29A Automatic Air Spray Gun and Can Marking System Part 07 979A NORDSON CORPORATION. AMHERST, OHIO. USA 2-454d TECHNICAL PUBLICATION Nordson Corporation Finishing Equipment Division ISSUED 4/85

More information

Fluidizing Pickup Tube Kits

Fluidizing Pickup Tube Kits Instruction Sheet P/N 303787-02 Introduction The fluidizing pickup tube kit retrofits your existing mobile powder system with fluidizing air. It injects fluidizing air at the pickup tube inlet with minimal

More information

This section contains: Coil Kit Seat E-200 Std Module, E-200 Std Plunger W/Ball Assy E-200 O-rings

This section contains: Coil Kit Seat E-200 Std Module, E-200 Std Plunger W/Ball Assy E-200 O-rings 7-1 ection 7 1. Introduction To order parts, call the Nordson Customer ervice Center at 800-241-8777 or your local Nordson representative. Use this five-column parts list and the accompanying illustration

More information

Vantage Individual Powder Spray Gun Controller

Vantage Individual Powder Spray Gun Controller Vantage Individual Powder Spray Gun Controller Customer Product Manual Issued 04/15 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject

More information

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the

More information

Series 3700VMPD Hot Melt Material Applicator

Series 3700VMPD Hot Melt Material Applicator Series 3700VMPD Hot Melt Material Applicator with DC Pump, L Manifold, and Vista Controller Customer Product Manual Part NORDSON CORPORATION Duluth, Georgia www.nordson.com Nordson Corporation welcomes

More information

ENGINE COOLING GROUP CONTENTS GENERAL INFORMATION SERVICE SPECIFICATIONS COOLANT SEALANT THERMOSTAT...

ENGINE COOLING GROUP CONTENTS GENERAL INFORMATION SERVICE SPECIFICATIONS COOLANT SEALANT THERMOSTAT... 14-1 GROUP 14 CONTENTS GENERAL INFORMATION 14-2 SERVICE SPECIFICATIONS 14-2 COOLANT 14-3 SEALANT 14-3 DIAGNOSIS 14-3 INTRODUCTION 14-3 TROUBLESHOOTING STRATEGY 14-3 SYMPTOM CHART 14-3 SYMPTOM PROCEDURES

More information

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1 5-1 Section 5 WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. NOTE: is an important

More information

Compatible Equipment

Compatible Equipment Valco Melton A Valco Cincinnati Inc. Business www.valcomelton.com Hot Melt Systems by Valco Melton Compatible Equipment Euro Version 1_2009 Hot Melt D, D-4E, NC, C, P & Kobra Series An ideal solution for

More information

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-0 effective 03/6/4 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex

More information

Page 1 of 19. Part# /10/2006

Page 1 of 19. Part# /10/2006 Part# 1002733-01 10/10/2006 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

ENGINE COOLING GROUP CONTENTS GENERAL INFORMATION SERVICE SPECIFICATIONS COOLANT SEALANT THERMOSTAT...

ENGINE COOLING GROUP CONTENTS GENERAL INFORMATION SERVICE SPECIFICATIONS COOLANT SEALANT THERMOSTAT... 14-1 GROUP 14 CONTENTS GENERAL INFORMATION 14-2 SERVICE SPECIFICATIONS 14-2 COOLANT 14-3 SEALANT 14-3 DIAGNOSIS 14-3 INTRODUCTION 14-3 TROUBLESHOOTING STRATEGY 14-3 SYMPTOM CHART 14-3 SYMPTOM PROCEDURES

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition

More information

TE-6300 Series Temperature Sensors

TE-6300 Series Temperature Sensors TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued July 14, 2008 Supersedes November 13, 2006 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety

More information

Colormax Powder Coating System Color Change Process

Colormax Powder Coating System Color Change Process Nordson Corporation OPERATOR S CARD P/N 1015049B Colormax Powder Coating System Color Change Process Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Mazda Reference MA014

Mazda Reference MA014 Subject: Fuel system pressure testing for fuel injected engines Symptom: Hard starting cold, power loss climbing hills, overall poor performance, engine surges and then stops running Source: Mazda service

More information

Air Operated Diaphragm Pumps

Air Operated Diaphragm Pumps Instructions Air Operated Diaphragm Pumps 30898ZAC For fluid transfer applications. For professional use only. Only models marked with (*) are approved for use in European explosive atmosphere locations.

More information

VWR Zero Air Generator

VWR Zero Air Generator Technical Information Installation, Operation, and Maintenance Manual VWR 89237-564 Zero Air Generator Figure 1 - VWR Zero Air Generator These instructions must be thoroughly read and understood before

More information

Econo-Coat Series II Powder Coating System

Econo-Coat Series II Powder Coating System Econo-Coat Series II Powder Coating System Customer Product Manual Issued 10/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to

More information

PREVIOUS GENERATION. Encore Manual Powder Spray Gun Trigger Switch Replacement. Introduction. Preparation. Gun Disassembly

PREVIOUS GENERATION. Encore Manual Powder Spray Gun Trigger Switch Replacement. Introduction. Preparation. Gun Disassembly Instruction Sheet P/N 1102249A Encore Manual Powder Spray Gun Trigger Switch Replacement Introduction Preparation Gun Disassembly The Encore trigger switch has been redesigned to eliminate the notches

More information

Low-Pressure Color Change Manifold

Low-Pressure Color Change Manifold Low-Pressure Color Change Manifold Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 33-939 or contact your local

More information

E-900 Electric Guns. Customer Product Manual Part A. Issued 6/03. NORDSON CORPORATION DULUTH, GEORGIA USA

E-900 Electric Guns. Customer Product Manual Part A. Issued 6/03. NORDSON CORPORATION DULUTH, GEORGIA USA E-900 Electric Guns Customer Product Manual Issued 6/0 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,

More information

Fisher 4194HS Differential Pressure Indicating Controllers

Fisher 4194HS Differential Pressure Indicating Controllers Instruction Manual Fisher 4194HS Differential Pressure Indicating Controllers Contents Introduction... 2 Scope of Manual... 2 Description... 2 Specifications... 5 Educational Services... 5 Installation,

More information

Hose Reel Kit for Multi-Pro 1200 and 1250 Sprayers. Installation Instructions. Form No Model No Serial No.

Hose Reel Kit for Multi-Pro 1200 and 1250 Sprayers. Installation Instructions. Form No Model No Serial No. Hose Reel Kit for Multi-Pro 00 and 50 Sprayers Model No. Serial No. 000000 and Up Form No. 9-8 Installation Instructions Installation Important You will need to purchase Teflon tape before installing this

More information

Sure Coat Individual Controllers

Sure Coat Individual Controllers Sure Coat Individual Controllers Customer Product Manual Issued 9/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local

More information

Pro Shot Grease Dispense Valve

Pro Shot Grease Dispense Valve Instructions Parts List Pro Shot Grease Dispense Valve 309032J For high pressure grease dispense. 8000 psi (55 MPa, 552 bar) Maximum Working Pressure Model No. 242055, Series B, 1/4 npt Fluid Inlet Model

More information

EGR heater plate removal and installation procedure has been added.

EGR heater plate removal and installation procedure has been added. NUMBER: 08 60-3 S.M. REF.: 8.3 ENGINE: EPA07 Series 60 DATE:June 2008 SUBJECT: EGR HEATER PLATE PUBLICATION: DDC-SVC-MAN-0005 EGR heater plate removal and installation procedure has been added. 8.3.1 REMOVAL

More information

ST01S Stress-Relieving Heat Limitations

ST01S Stress-Relieving Heat Limitations Uniform Procedures For Collision Repair ST01S Stress-Relieving Heat Limitations 1. Description This procedure describes methods and inspection requirements for using heat to relieve stress in steel. 2.

More information

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model

More information

LAWN SPRINKLER, IRRIGATION PUMP

LAWN SPRINKLER, IRRIGATION PUMP LAWN SPRINKLER, IRRIGATION PUMP MODEL #, SP0P, SP5P, SP20P, EL0P, EL5P, EL20P SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

More information

Piston Cooling Nozzle, Replacement

Piston Cooling Nozzle, Replacement Volvo Trucks North America Greensboro, NC USA This Service Bulletin replaces Service Bulletin 221-49, Piston Cooling, dated (1.2007), publication no. PV776-20177472. DService Bulletin Trucks Date Group

More information

Encore HD Manual Powder Spray Gun

Encore HD Manual Powder Spray Gun Encore HD Manual Powder Spray Gun Customer Product Manual Issued 04/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR 125-5 P/N 9168800100 Publication: 9168800990 Revision: J 03/09 INTRODUCTION This instruction manual provides information about the operation and installation

More information

Product Name. Paraffin Dispenser. Operator s Manual. Histology Innovation for a NEW Generation PD-120; PD-220. A Division of General Data Healthcare

Product Name. Paraffin Dispenser. Operator s Manual. Histology Innovation for a NEW Generation PD-120; PD-220. A Division of General Data Healthcare A Division of General Data Healthcare Histology Innovation for a NEW Generation Pub No.: OM PD-1 June 2013, Version 1.8 PD-120; PD-220 Operator s Manual Product Name Here Catalog #s Paraffin Dispenser

More information

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL EFFECTIVE JULY 19, 2017 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items

More information

1329I Integrated Drive/Motor CE Filter Option Kit

1329I Integrated Drive/Motor CE Filter Option Kit Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the

More information

ROYAL Cyclone 1 Extruder Operators Instruction Manual

ROYAL Cyclone 1 Extruder Operators Instruction Manual ROYAL Cyclone 1 Extruder Operators Instruction Manual Read and understand the instructions in this Manual before using this machine! Keep this Manual with the Cyclone Extruder at all times. It is the Cyclone

More information

Encore Manual Powder Spray Gun Trigger Switch Replacement

Encore Manual Powder Spray Gun Trigger Switch Replacement Instruction Sheet P/N 1096694A Encore Manual Powder Spray Gun Trigger Switch Replacement Preparation 1. Remove the nozzle nut, nozzle, and electrode assembly. 2. Disconnect the powder feed hose adapter,

More information

Gearbox Oil Pump - Troubleshooting Guide

Gearbox Oil Pump - Troubleshooting Guide Haas Technical Documentation Gearbox Oil Pump - Troubleshooting Guide Scan code to get the latest version of this document Translation Available 50-taper spindle: Oil-pump motor [1]. Gearbox [2]. Scavenge

More information

Description. Repair. Rhinor XD2 Type-H Low Level Drum Proximity Sensor. Replacing the Proximity Sensor

Description. Repair. Rhinor XD2 Type-H Low Level Drum Proximity Sensor. Replacing the Proximity Sensor Rhinor XD2 Type-H Low Level Drum Proximity Sensor Description See Figure 1. The Rhino XD2 Type-H Low Level Drum Proximity Sensor (1) monitors the distance between the bottom of the follower plate and the

More information

Lube Level Maintainer

Lube Level Maintainer Lube Level Maintainer Model LM500-TF-ATEX Installation Instructions 00-02-0745 2013-09-16 Section 15 Ex ic IIC T5 Gc X -20 o C < Ta < 85 o C NOTE: To use in an ATEX environment the metal vent cap must

More information

TE-6300 Series Temperature Sensors Catalog Page

TE-6300 Series Temperature Sensors Catalog Page Code No. LIT-1900217 Issued February 2017 TE-6300 Series Temperature Sensors Catalog Page Description The TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature

More information

N-02 MAINTENANCE MECHANIC TRAINING SKILL DEVELOPMENT GUIDE

N-02 MAINTENANCE MECHANIC TRAINING SKILL DEVELOPMENT GUIDE N-02 MAINTENANCE MECHANIC TRAINING SKILL DEVELOPMENT GUIDE Duty N: System Troubleshooting N-02: Troubleshoot Pneumatic System Issued 6/01/98 Task Preview Troubleshoot Pneumatic System The Maintenance Mechanic,

More information

Instruction Manual for the 110 VAC Draw-off Controller System

Instruction Manual for the 110 VAC Draw-off Controller System 1 Instruction Manual for the 110 VAC Draw-off Controller System Introduction This Electronic Draw-off Controller is specifically designed for use in the Maple syrup industry. It has several features designed

More information

3 Scotch-Weld. User s Manual. Polyurethane Reactive (PUR) Easy Adhesive Applicator

3 Scotch-Weld. User s Manual. Polyurethane Reactive (PUR) Easy Adhesive Applicator 3 Scotch-Weld Polyurethane Reactive (PUR) Easy Adhesive Applicator 120V. USA 100V. JAPAN 120V. USA REFURB User s Manual Use only with 3M Scotch-Weld Polyurethane Reactive (PUR) Easy Adhesives Please read

More information

Exhaust System Installation Corvette C6

Exhaust System Installation Corvette C6 CORVETTE C6 Exhaust System Installation 2009+ Corvette C6 Recommended Tools: 13 mm Socket 15 mm Socket 18 mm Socket 15 mm Open End Wrench Torque Wrench (20-100 ft.-lb.) Drive extensions for Ratchet (MINIMUM

More information

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007 Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007 Be certain to read this manual thoroughly before proceeding with unpacking and installation. TABLE OF CONTENTS Topic

More information

Type Type I/P & E/P Transducers

Type Type I/P & E/P Transducers Type 1500 I/P & E/P Type 1500 Description Principle of Operation (ee Fig. 2 and 6) The T-1500 Transducer is a force balance device in which a coil is suspended in the field of a magnet by a flexure. Current

More information

A CAUTION: The kit should not be fitted on Series 3800 or 3900

A CAUTION: The kit should not be fitted on Series 3800 or 3900 Series 3000 O:l Pump Installation Kit Instructions 6-52 Page O:l SINGLE ACTING PUMP INSTALLATION (P/N 3 598) KIT INTRODUCTION. The O:l Single Acting Pump Installation Kit gives you all the necessary items

More information

STP-MLD. Installation and Owner s Manual

STP-MLD. Installation and Owner s Manual The Leader in Submersible Technology Mechanical Leak Detector STP-MLD STP-MLD-D STP-MLD-E Gasoline Diesel Flexible Pipe STP-MLD STP-MLD Installation and Owner s Manual 4805 Voges Rd., P.O. Box 139 McFarland,

More information

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions , IECEx EPS 16.0053X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

PRO Auto Xs Air Spray Gun

PRO Auto Xs Air Spray Gun Instructions/Parts List ELECTROSTATIC, FOR WATERBORNE COATINGS PRO Auto Xs Air Spray Gun 309457G EN Part No. 244591, Series A 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure 100 psi (0.7 MPa, 7 bar)

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

Fisher 377 Trip Valve

Fisher 377 Trip Valve Instruction Manual Fisher 377 Trip Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 3 Educational Services... 3 Installation... 4 Supply Pressure Requirements...

More information

Technical Data for 3100 Series Melters

Technical Data for 3100 Series Melters Part D, Section 1 This section covers the following unit configurations. Model 3100 Voltage All Pump All Manifold All Control All 1-3000 D 1-0 1-3000 D 1-1 Section D 1 1. Specifications Viscosity Range

More information

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type Pneumatic Control Valves Type 3347-1 and Type 3347-7 Hollow-mold cast body with welding ends Full-mold cast body with threaded connections Fig. 1 Type 3347-7 Control Valve with Type 3277 Actuator and integral

More information

Fisher 4194S Differential Pressure Controllers

Fisher 4194S Differential Pressure Controllers Instruction Manual 4194S Controllers Fisher 4194S Differential Pressure Controllers Contents 1. Introduction... 2 Scope of Manual... 2 Description... 2 Specifications... 5 Educational Services... 5 2.

More information