Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Size: px
Start display at page:

Download "Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)"

Transcription

1 Part B, Section 2 Model This section covers the following unit configurations. Voltage V 3400V 3500V Pump Piston (E, F, G) Manifold 4-Port (A) 6-Port (B, C) 2-Port (S, T) Vista Standard (V)

2 B 2-0

3 B 2-1 Section B 2 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. 1. Introduction This section includes control system troubleshooting and repair procedures. Refer to the parts lists for the part number of any component that needs to be replaced. If you try all the troubleshooting suggestions in this section and still need assistance solving control system problems, call your Nordson representative. The following sections of this manual contain additional information on the control system: Description includes an overview of each of the functional areas of the operator panel. Installation includes procedures for connecting output contacts, connecting electrical service, and programming your unit. Wiring Diagrams includes a set of wiring diagrams for your system. If your unit has any special options, such as an input/output (I/O) board or a low-level indicator, refer to the Options section at the end of this manual for troubleshooting and repair procedures. Refer to the Hydraulics section for troubleshooting procedures, repair procedures, and parts lists for the unit s pump and manifold assemblies.

4 B Overview of the System The Vista control system controls how your unit operates. The control system includes a variety of printed circuit boards (hereafter referred to as boards) and other components that you should be familiar with to safely troubleshoot and repair your unit. Assembly See Figure B 2-1. The main components of the control system are the control-end frame, the control assembly, and the operator panel. The control assembly is mounted on the inside of the control-end frame. The operator panel is mounted on the front of the control-end frame. The control assembly is made up of three boards that are required for your unit to function properly. Refer to the following table. Table B 2-1 Assembly Boards Assembly Board Function Power board board Display board Provides power to the unit and supplies the heater power for most of the unit s heated components Contains the Vista software chip and controls how the unit operates Allows the displays to function Fig. B 2-1 Assembly Components 1. Power board 4. -end frame 2. board 5. Operator panel 3. Display board

5 B 2-3 Unit-Specific Boards See Figure B 2-2. The control system also includes any unit-specific boards that are required for your unit to function properly. The presence of these boards varies depending on the configuration of the unit. Refer to the following table. Unit-Specific Board 480 VAC distribution board 5/6 hose/gun board Table B 2-2 Unit-Specific Boards Function Distributes incoming power to the power board Expands a unit s temperature-control capacity from four hoses/guns to six hoses/guns, supplying the heater power for hoses 5 6 and guns 5 6 Optional Input/Output Board See Figure B 2-2. Your unit may have an optional input/output (I/O) board. The I/O board is not required for a unit to function properly. Refer to Series 3000V Input/Output Board in the Options section at the end of this manual for information about the I/O board, including troubleshooting procedures, repair procedures, and a parts list A Fig. B 2-2 Unit-Specific Boards and I/O Board VAC distribution board 2. 5/6 hose/gun board 3. I/O board

6 B 2-4 System on 480 Vac Three-Phase Units Your hot melt unit operates on 480 VAC three-phase (3 ) incoming power, which you connected to a terminal block on the 480 VAC distribution board. A 480 VAC/230 VAC 1 isolation transformer provides 230 VAC power to the control assembly. The tank heaters operate on 480 VAC power. A solid-state relay controls the heater power to the tank heaters through the control board. Fuses F1, F2, and F3 on the 480 VAC distribution board provide protection for the 480 VAC power section, which includes the transformer and the tank heaters. Gun and hose heaters are powered by the power board and operate at 230 VAC. The tank heater circuit on the power board is not used on 480 VAC units. 3. Troubleshooting Tables The following troubleshooting tables describe the kinds of control system problems you may encounter and provide corrective actions for handling those problems. When necessary, the tables refer to more detailed troubleshooting procedures. Refer to the appropriate troubleshooting table for the type of problem you are experiencing: Internal, Hose, or Gun Zone Not Heating Settings Changed or Lost Unit Not Powering On System Indicating a Warning - Out-of-Band Warning - Under-Temperature (UT) Warning System Indicating a Fault - Over-Temperature (OT) Fault - Resistance Temperature Detector (RTD) Fault - Fault-Code Fault (F1 F7)

7 B 2-5 Electrical Safety During Troubleshooting Before performing troubleshooting activities inside the unit s electrical enclosure, you should exhaust all methods of troubleshooting the problem with the electrical enclosure closed or with the power off. The troubleshooting tables and procedures in this section are organized using this methodology. In general, you should perform troubleshooting activities as follows: Check the displays and lights for warnings, faults, and other status information. Check your programmed settings to make sure they haven t been changed. Refer to Records of System Settings in the Installation section. Check for continuity and grounding between system components (unit, guns, hoses, and other equipment). Make sure your branch circuit disconnect switch is properly installed. Make sure your power supply is supplying the proper voltage. Prioritize troubleshooting activities to limit exposure to live power. Perform troubleshooting activities involving live power last. Understand your system electrically and mechanically before opening the electrical enclosure. Pay special attention to system power distribution and to I/O interfaces with other equipment. Identify and eliminate potential electrical shock hazards in the environment surrounding your unit. Opening and Closing the Electrical Enclosure To troubleshoot control system problems or to make any repairs, you may need to access the electrical enclosure. Use these procedures as directed to safely access the electrical enclosure.

8 B 2-6 Opening WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Place the unit s POWER switch in the off position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. See Figure B 2-3. Loosen the captive screws on the electrical enclosure lid, lift the lid from the unit, and prop it against the pump cover. Take care not to disconnect the ground wire. 3. Make sure the support strap is not wrapped around any board components. Untangle the strap if necessary. 4. Loosen the two captive screws on either side of the control-end frame and lower the frame. You may need to pull the front and rear covers apart to release the frame. 5. Avoid direct contact with internal electrical connections, components, or wiring. 6. Make sure all ground wires are securely connected. Î Î Î Î A Fig. B 2-3 Opening the Electrical Enclosure

9 B 2-7 Closing 1. Reconnect any ground wires that were disconnected during troubleshooting or repair activities. 2. Raise the control-end frame into place and tighten the captive screws on each side of the frame. You may need to pull the front and rear covers apart to position the frame. 3. Position the electrical enclosure lid on top of the unit and secure it with the captive screws. 4. Remove the lock-out and restore power to the system. Internal, Hose, or Gun Zone Not Heating If a tank, hose, or gun will not heat, use this troubleshooting table. Problem Possible Cause Corrective Action Internal, hose, or gun zone not heating Zone setpoint temperature below 38 C (100 F) Check the setpoint temperature for the zone. The setpoint temperature must be 38 C (100 F) or above for the zone to heat. Refer to Programming TEMPERATURE s in the Installation section to program setpoint temperatures.

10 B 2-8 Settings Changed or Lost Use the following table to troubleshoot changed or lost settings (memory). Because the control system memory is stored on the microprocessor chip and does not require the protection of a battery backup, your settings cannot be lost during a brownout or a power failure. Problem Possible Cause Corrective Action 1. One or more settings changed Someone entered programming mode and changed one or more settings Use the password-enable feature to protect your settings. Refer to System Programming Procedures in the Installation section. Be sure to record your settings in the Records of System Settings at the end of the Installation section. 2. All settings lost Software upgraded to latest version by replacing software chip (all custom settings are lost during this procedure and are replaced by the factory default settings) Defective microprocessor chip Reprogram your unit. Refer to System Programming Procedures in the Installation section. Replace the control board. Refer to Replacing a Assembly Board in Repair Procedures. Unit Not Powering On If your unit will not power on, use this troubleshooting table. WARNING: Risk of equipment damage, personal injury, or death. Some troubleshooting procedures require you to perform work inside the electrical enclosure with the power on. Follow electrical safety procedures and observe all high-voltage indicators. Refer to Electrical Safety During Troubleshooting and Opening and Closing the Electrical Enclosure before performing any troubleshooting procedure.

11 B 2-9 Problem Possible Cause Corrective Action Displays do not illuminate or displays illuminate but unit will not power on and no faults are displayed No input power Defective POWER switch Incorrect voltage plug at X3 on power board or plug not connected Blown fuse or fuses on 480 VAC distribution board Blown fuse or fuses on power board Defective harness on 480 VAC distribution board or defective transformer Contactor K1 on 480 VAC distribution board or power board not engaging Power board not properly connected to control board Defective power board or control board Make sure the power is turned on at your branch circuit disconnect switch and that your power supply is supplying 480 VAC to the unit. Make sure the voltage measures 480 VAC at TB1 on the 480 VAC distribution board. If necessary, check your electrical connections at TB1. Refer to Connecting Electrical Service in the Installation section. Check the POWER switch. Refer to Checking the POWER Switch in Troubleshooting Procedures. Make sure the voltage plug at X3 on the power board is part and that the plug is securely connected. See the illustration in the Parts section for the location of the voltage plug. Use an ohmmeter to check fuses F1 through F4 on the 480 VAC distribution board. Replace blown fuses. Refer to Replacing a Fuse in Repair Procedures. Use an ohmmeter to check fuses F9 and F10 on the power board. Replace blown fuses. Refer to Replacing a Fuse in Repair Procedures. Check the harnesses and transformer. Refer to Checking the 480 VAC Distribution Board Harnesses and the Transformer in Troubleshooting Procedures. While pressing the unit s HEATERS key on and off, listen for the K1 contactors to engage. You can also open the unit and visually examine the contactors to see if they are engaging. See Figure B 2-4 for the location of K1 on each board. If K1 is not engaging, replace the 480 VAC distribution board or the power board as appropriate. Refer to Replacing a Unit-Specific Board or Replacing a Assembly Board in Repair Procedures. Make sure the power board is properly connected to the control board at XP1. The pins from the control board should extend through XP1 on the power board. Replace the control assembly. Refer to Replacing the Assembly in Repair Procedures.

12 B 2-10 Unit Not Powering On (contd.) X1 X3H XP6 XS2H XP1 XP1 K1 X3 XP3 X2 X4 XP5 XP4A XS3 XS4 X2H Q17 TB1 XS1H TB J9 J4 XS2 J2 XS1 L1 L2 L3 N XP2 X1H A Fig. B 2-4 Location of Connectors on Boards 1. Power board 3. 5/6 hose/gun board VAC distribution board 2. board System Indicating a Warning During a warning condition, the unit continues to function normally. The control system indicates a warning as follows: The FAULT light flashes and turns off or flashes continuously. The Selector display shows a zone number. NOTE: Each heated component (each hose, each gun, and the tank) is referred to as a zone. When the Selector display shows a zone number, the INTERNAL, HOSE, or GUN light turns on. In combination, these indications identify which zone is affected. Refer to Table B 2-3. The Multipurpose display shows either a temperature reading or a flashing UT for the affected zone.

13 B 2-11 Table B 2-3 Determining the Affected Zone Zone Number in Selector Display (See Note A) Affected Zone INTERNAL Light On HOSE Light On GUN Light On 1 Tank Hose 1 Gun 1 2 Hose 2 Gun 2 3 Hose 3 Gun 3 4 Hose 4 Gun 4 5 (See Note B) 6 (See Note B) Hose 5 Gun 5 Hose 6 Gun 6 NOTE A: For example, if the Selector display shows the number 3 and the GUN light is on, then the affected zone is gun 3. B: Some units can accept only four hoses and four guns. Out-of-Band Warning When the FAULT light. And the Selector display And the Multipurpose display It means Do this is OFF (See Note A) Shows a zone number (refer to Table B 2-3) Shows the setpoint temperature of the affected zone The actual temperature of the indicated zone is out-of-band. Wait to see if the temperature stabilizes at the setpoint. You may want to change your out-of-band temperature setpoints. See Note B. NOTE A: The warning output contact is open and the fault output contact is closed. For more information on these output contacts, refer to Connecting Output Contacts in the Installation section. B: You can choose the degree to which a zone s temperature may deviate from its temperature setpoint (Features 5 19) and still stay within the temperature setpoint band. You should base your out-of-band temperature setpoints on your adhesive application requirements. Refer to System Programming Procedures in the Installation section to program out-of-band temperature setpoints.

14 B 2-12 Under-Temperature (UT) Warning WARNING: Risk of equipment damage, personal injury, or death. Some troubleshooting procedures require you to perform work inside the electrical enclosure with the power on. Follow electrical safety procedures and observe all high-voltage indicators. Refer to Electrical Safety During Troubleshooting and Opening and Closing the Electrical Enclosure before performing any troubleshooting procedure. Table B 2-4 Identifying and Correcting UT Faults FAULT Light Selector Display Shows... Multipurpose Display Shows... Problem Solution OFF (See Note A) Zone number of the affected zone. Setpoint temperature of the faulted zone. The zone is out of band. Wait for 5 minutes to see if the temperature stabilizes at the setpoint. Zone number of the affected zone. UT flashing (See Note B) The system is under temperature because: No or insufficient power is being applied to the unit. The heater connection of the faulted zone is not secure. Zone fuses are bad. The heater of the faulted zone is bad. The power board or control board is defective. Check that the applicator is connected to the main power supply. If it is connected, check that electrical service connections are correct. Check the XS1 and XS2 heater connections on the main power board for the corresponding zone. Replace appropriate fuses. Replace the heater of the faulted zone. For a hose or gun fault, refer to the manual that came with your hose or gun. For an internal (tank) fault, the cast-in heaters of the tank require that you replace the tank. Replace the power board or control board. NOTE A: UT (undertemperature) occurs when a heater zone is more than 19.5 C (35 F) under the setpoint temperature. B: A UT warning can appear as a result of a zone that is either heating too slowly or not heating at all. The minimum time it takes for Vista to show a UT warning time as a result of a zone heating too slowly or not heating at all is 15 minutes.

15 B Press the CLEAR FAULTS key and wait for the system to return to the system-ready state. 2. If the warning disappears and the unit appears to be working again, the voltage to the unit may have temporarily sagged or you may have an intermittent problem. Repetitive warnings in the same zone indicate a problem with the circuitry in that zone or an intermittent RTD failure. Take the following steps to troubleshoot intermittent under-temperature warnings: a. Check for a change in environmental conditions, such as added ventilation or sources of drafts. A cold draft can keep your unit, hoses, and guns from heating. b. Make sure the power is turned on at your branch circuit disconnect switch and that your power supply is supplying the proper voltage to the unit. c. Check all hose and gun electrical plugs. Make sure the connections are tight and free of corrosion. d. Check your operating temperature setpoints to make sure they haven t been changed. Refer to Records of System Settings in the Installation section. e. If the affected zone is a hose or gun, replace the hose or gun with a hose or gun that is known to be good. If the warning disappears, replace the defective hose or gun. If the warning still appears, continue to the next step. 3. If the warning still appears after you press the CLEAR FAULTS key and after you have taken the actions in step 2, take the following steps. a. Check for loose heater connections on the board that supplies the heater power for the affected zone. Refer to Table B 2-6 for heater connector locations. For example, check the harnesses connected to X1 and X2 on the power board to check the heater connections for hoses 1 4 or guns 1 4. See Figure B 2-4 for the location of connectors on boards.

16 B 2-14 Under-Temperature (UT) Warning (contd.) b. Use an ohmmeter to check the fuse or fuses on the board that supplies the heater power for the affected zone. Refer to Figure B 2 8 for fuse locations. Replace the appropriate fuse or fuses. Refer to Replacing a Fuse in Repair Procedures. If the fuse blows again, make sure the heater is not shorted to the ground. c. If the affected zone is the tank, make sure the harness connected to J2 on the power board is secure or check the thermostat. See Figure B 2-4 for the location of J2 on the power board. To check a thermostat, refer to Checking a Thermostat in Troubleshooting Procedures. d. Check the K1 contactors on the 480 VAC distribution board and the power board. While pressing the unit s HEATERS key on and off, listen for the K1 contactors to engage. You can also open the unit and visually examine the contactors to see if they are engaging. See Figure B 2-4 for the location of K1 on the 480 VAC distribution board and the power board. If K1 is not engaging, replace the 480 VAC distribution board or the power board as appropriate. Refer to Replacing a Unit-Specific Board or Replacing a Assembly Board in Repair Procedures. e. Check the heater or heater circuit of the affected zone. Refer to Checking a Heater or Heater Circuit in Troubleshooting Procedures. f. If the warning condition still appears after you have taken all the actions in this step, replace the control assembly. Refer to Replacing the Assembly in Repair Procedures.

17 B 2-15 System Indicating a Fault A fault condition causes the unit to shut down. The control system indicates a fault as follows: The FAULT light either turns on and stays on or flashes for two minutes and then stays on. The Selector display shows either a zone number or the letter F. NOTE: Each heated component (each hose, each gun, and the tank) is referred to as a zone. If the Selector display shows a zone number, the INTERNAL, HOSE, or GUN light turns on. In combination, these indications identify the faulted zone. Refer to Table B 2-5. The Multipurpose display shows either a flashing OT or RTD for the faulted zone or a fault code (F1 F7). The heaters turn off. Whenever the heaters turn off, the pump stops. Table B 2-5 Determining the Faulted Zone Zone Faulted Zone Number in Selector Display (See Note A) INTERNAL Light On HOSE Light On GUN Light On 1 Tank Hose 1 Gun 1 2 Hose 2 Gun 2 3 Hose 3 Gun 3 4 Hose 4 Gun 4 5 (See Note B) 6 (See Note B) Hose 5 Gun 5 Hose 6 Gun 6 NOTE A: For example, if the Selector display shows the number 3 and the GUN light is on, then the faulted zone is gun 3. B: Some units can accept only four hoses and four guns.

18 B 2-16 Over-Temperature (OT) Fault WARNING: Risk of equipment damage, personal injury, or death. Some troubleshooting procedures require you to perform work inside the electrical enclosure with the power on. Follow electrical safety procedures and observe all high-voltage indicators. Refer to Electrical Safety During Troubleshooting and Opening and Closing the Electrical Enclosure before performing any troubleshooting procedure. When the FAULT light And the Selector display And the Multipurpose display It means Do this Turns on (See Note A) Shows a zone number (refer to Table B 2-5) Flashes OT (See Note B) A zone s actual temperature has reached the over-temperature setpoint entered in Feature 3. The default setting is 218 C (425 F). Refer to the following procedure. NOTE A: When the FAULT light turns on, the warning output contact is closed and the fault output contact is open. When the FAULT light is off, both output contacts are closed. For more information on these output contacts, refer to Connecting Output Contacts in the Installation section. B: You should base your over-temperature setpoints on your adhesive application requirements. Refer to System Programming Procedures in the Installation section to program over-temperature setpoints. 1. Press the CLEAR FAULTS key. 2. If the fault disappears and the unit appears to be working again, you may have an intermittent problem. Repetitive faults in the same zone indicate a problem with the circuitry in that zone or an intermittent RTD failure. Electrical noise from DC-drive motors may cause the triacs that control heater power on the power board to close independent of the control system. Take the following steps to troubleshoot intermittent over-temperature faults: a. Check your operating temperature setpoints to make sure they haven t been changed. Refer to Records of System Settings in the Installation section.

19 B 2-17 b. To verify that something other than the control system is affecting a heated zone, turn on the Display Heater Proportioning feature (Feature No. 21) for the affected zone. When the display blinks on and off, it means the control system is proportioning heat control to the heater. During proportioning, the temperature displayed for the zone should stay fairly constant, within +/ 1 F. If the temperature continues to rise during proportioning, then something other than the control system is closing the triacs on the power board and causing the heaters to heat. If electrical noise from DC drives is causing the overheating problem, then you may be experiencing problems with other equipment in your facility. Take the following steps to solve electrical noise problems: Install the proper line reactor. Consult with the DC drive manufacturer for the appropriate line reactor size. Electrically ground the hot melt unit to the parent machine using as short a length of twisted cable as possible. If the triacs continue to close after the hot melt unit is grounded to the parent machine, install a line filter on each input power line to the hot melt unit. Connect the filter line-to-line. Refer to Parts for the line filter part number. For a three-phase system, order three filters. c. If the faulted zone is a hose or gun, replace the hose or gun with a hose or gun that is known to be good. If the fault disappears, replace the defective hose or gun. If the fault remains, continue to the next step. 3. If the fault remains after you press the CLEAR FAULTS key and after you have taken the actions in step 2, check the heater or heater circuit of the faulted zone. Refer to Checking a Heater or Heater Circuit in Troubleshooting Procedures. 4. If the fault remains after you have taken all the actions in this procedure, replace the control assembly. Refer to Replacing the Assembly in Repair Procedures.

20 B 2-18 Resistance Temperature Detector (RTD) Fault Nordson offers two test plugs that simplify the troubleshooting of RTD faults. These test plugs help you quickly and easily determine whether the problem is a gun, hose, or tank RTD problem or a control system problem. Refer to Parts for the kit part number. When the FAULT light And the Selector display And the Multipurpose display It means Do this Flashes for two minutes then stays on continuously (See Note A) Shows a zone number (refer to Table B 2-5) Flashes RTD (See Note B) The RTD or RTD circuit of the indicated zone is open or shorted. Refer to Checking an RTD or RTD Circuit in Troubleshooting Procedures. NOTE A: When the FAULT light flashes, the warning output contact is open and the fault output contact is closed. After a two-minute delay, the warning output contact closes and the fault output contact opens. When the FAULT light is off, both output contacts are closed. For more information on these output contacts, refer to Connecting Output Contacts in the Installation section. B: The actual-temperature display will show 260 C (500 F) if the RTD is open. It will show 0 C (0 F) if the RTD is shorted.

21 B 2-19 Fault-Code Fault (F1 F7) When the FAULT light And the Selector display And the Multipurpose display It means Do this Turns on (See Note A) Shows the letter F Shows the number 2 The power board screws are loose, causing a faulty ground connection. Tighten the power board screws. Shows the letter F Shows the number 1, 2, 3, 5, or 6 The control board is defective. Turn the unit off, then back on again to see if the problem recurs. If it recurs, replace the control board or replace the control assembly. Refer to Replacing a Assembly Board or Replacing the Assembly in Repair Procedures. Shows the letter F Shows the number 4 There is a brownout condition. (See Note B) Correct the cause of the brownout. Shows the letter F Shows the number 7 The seven-day clock battery is dead. (See Note C) Replace the control board or the control assembly. Refer to Replacing a Assembly Board or Replacing the Assembly in Repair Procedures. NOTE A: When the FAULT light turns on, the warning output contact is closed and the fault output contact is open. When the FAULT light is off, both output contacts are closed. For more information on these output contacts, refer to Connecting Output Contacts in the Installation section. B: A brownout occurs when the power supply voltage falls below the voltage needed to maintain system operation. When this happens, the control system stops normal operation. The system will resume normal operation once the brownout condition is corrected. C: If the unit and the seven-day clock feature are turned on and the clock battery dies, the CLOCK light will flash. If the unit is then subject to a power cycle or power interruption, the displays will indicate fault code 7. However, if the clock feature is not turned on and the clock battery dies, the unit will not indicate a fault. When the clock battery is dead, the unit will continue to operate normally except for clock-related functions.

22 B Troubleshooting Procedures Use these procedures as directed in Troubleshooting Tables to further troubleshoot control system problems. Checking the POWER Switch Follow this procedure to check the POWER switch. WARNING: Risk of equipment damage, personal injury, or death. This procedure requires you to perform electrical troubleshooting with the power on. Use extreme caution and refer to Electrical Safety During Troubleshooting and Opening and Closing the Electrical Enclosure for instructions on safely working inside the electrical enclosure. 1. Turn on power to the unit at the branch circuit disconnect switch. 2. With the unit s POWER switch in the off position, measure the voltage across J4 positions 1 and 4 on the power board. Voltage does not measure 230 VAC: replace the POWER switch and harness. Voltage measures 230 VAC: normal indication. Continue to the next step. 3. With the unit s POWER switch in the on position, measure the voltage across J4 positions 2 and 5 on the power board. Voltage does not measure 230 VAC: replace the POWER switch and harness. Voltage measures 230 VAC: normal indication. Return to the Unit Not Powering On troubleshooting table.

23 B 2-21 Checking the 480 Vac Distribution Board Harnesses and the Transformer Follow this procedure to check the harnesses on the 480 VAC distribution board and the transformer. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Place the unit s POWER switch in the off position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Use an ohmmeter to check the continuity of the harnesses connected to the following connectors on the 480 VAC distribution board and take action as directed. See Figure B 2-4 for the location of connectors on boards. Harness Connector Check continuity across harness pins 480 VAC distribution board to transformer primary winding 480 VAC distribution board to transformer secondary winding 480 VAC distribution board to TB1A and TB1B Continuity exists? Action X1D 1 and 3 No Replace the harness. Yes Go to the next step. X1D 6 and 8 No Replace the harness. Yes Go to the next step. X3D 2 and 4 No Replace the harness. Yes Go to the next step.

24 B 2-22 Checking the 480 Vac Distribution Board Harnesses and the Transformer (contd.) 4. Use an ohmmeter to measure the resistance of the harnesses connected to the following connectors on the 480 VAC distribution board and take action as directed. Harness Connector Measure resistance across harness pins 480 VAC distribution board to transformer primary winding 480 VAC distribution board to transformer secondary winding 480 VAC distribution board to TB1A and TB1B Reading Action X1D 1 and 3 High ohms Replace the transformer Low ohms Go to the next step. X1D 6 and 8 High ohms Replace the transformer Low ohms Go to the next step. X3D 2 and 4 High ohms Replace the harness. Low ohms Go to the next step. WARNING: Risk of equipment damage, personal injury, or death. This procedure requires you to perform electrical troubleshooting with the power on. Use extreme caution and refer to Electrical Safety During Troubleshooting and Opening and Closing the Electrical Enclosure for instructions on safely working inside the electrical enclosure. 5. Restore power to the unit at the branch circuit disconnect switch and turn the unit on. 6. Use a voltmeter to measure the voltage at pins 1, 2, and 3 of the harness connected to X1D on the 480 VAC distribution board. Voltage does not measure VAC: make sure the unit is connected to the input power supply and that 480 VAC is being supplied. Make sure the electrical connections at TB1 on the 480 VAC distribution board are correct. Refer to Connecting Electrical Service in the Installation section. Voltage measures VAC: normal indication. Go to the next step.

25 B Repeat the voltage measurement at pins 6 and 8 of the harness connected to X1D. Voltage does not measure VAC: defective harness or transformer. Replace the harness. If replacing the harness does not solve the problem, replace the transformer. Voltage measures VAC: normal indication. Go to the next step. 8. Measure the voltage at pins 2 and 4 of the harness connected to X3D on the 480 VAC distribution board and at TB1 positions A and B on the power board. Voltage does not measure 230 VAC: defective harness or transformer. Replace the harness. If replacing the harness does not solve the problem, replace the transformer. Voltage measures 230 VAC: normal indication. Return to the Unit Not Powering On troubleshooting table. Checking a Heater or Heater Circuit Follow this procedure to check a heater or heater circuit. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Place the unit s POWER switch in the off position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Check the heater by measuring its resistance at the heater connector harness pins. Refer to Table B 2-6 to determine which board the zone s heater connectors are located on. See Figure B 2-4 for the location of the connectors on the boards. Remove the harness from the connector and measure the resistance across the harness pins identified in Table B 2-6. Resistance reading of zero (0): heater short circuit. Check for a short in the heater circuit and repair the short. Infinite resistance reading: open heater circuit or heater. Go to the next step.

26 B 2-24 Checking a Heater or Heater Circuit (contd.) Table B 2-6 Heater Connector Locations and Harness Pins for Measuring Resistance Problem Zone Connector Location Connector: Pin Resistance Range Hose 1 Power board X1: 1 and X2: ohms Hose 2 Power board X1: 3 and X2: ohms Hose 3 Power board X1: 5 and X2: ohms Hose 4 Power board X1: 7 and X2: ohms Hose 5 (See Note A) 5/6 hose/gun board X1H: 4 and X2H: ohms Hose 6 (See Note A) 5/6 hose/gun board X1H: 2 and X2H: ohms Gun 1 Power board X1: 2 and X2: ohms Gun 2 Power board X1: 4 and X2: ohms Gun 3 Power board X1: 6 and X2: ohms Gun 4 Power board X1: 8 and X2: ohms Gun 5 (See Note A) 5/6 hose/gun board X1H: 3 and X2H: ohms Gun 6 (See Note A) 5/6 hose/gun board X1H: 1 and X2H: ohms Tank 480 VAC distribution board NOTE A: Some units can accept only four hoses and four guns. X5DA and X5DB ohms 4. Check the continuity of the heater circuit by measuring the heater resistance at a point in the circuit that is closer to the heater. If the faulted zone is a hose or gun, measure the resistance at the hose or gun electrical plug. Refer to your hose or gun manual for a diagram of the electrical plug and for procedures for replacing the gun heater. If a hose heater is defective, replace the hose. If the faulted zone is the tank, measure the resistance at the tank heater connectors. If you measure infinite or zero (0) resistance at the tank heater connectors, you must install a new tank. Refer to the Tank section. 5. Replace the control board or the control assembly. Refer to Replacing a Assembly Board or Replacing the Assembly in Repair Procedures.

27 B 2-25 Checking a Thermostat Use this procedure to check a thermostat. WARNING: System or material pressurized. Relieve pressure. Failure to observe this warning may result in serious burns. 1. Relieve system pressure. Refer to Relieving System Pressure in the Maintenance section. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 2. Place the unit s POWER switch in the off position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 3. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 4. Remove the thermostat. Refer to RTD or Thermostat Removal in Repair Procedures. 5. Connect an ohmmeter set on the lowest resistance scale across the thermostat; then heat the thermostat with a flameless electric heat gun. Short circuit before thermostat reaches temperature and open circuit when thermostat reaches temperature: normal indication. Return to the appropriate troubleshooting table. Short circuit or low resistance at high temperature: defective thermostat. Replace the thermostat. Refer to Replacing an RTD or a Thermostat in Repair Procedures.

28 B 2-26 Checking an RTD or RTD Circuit Follow this procedure to check an RTD or RTD circuit. NOTE: If the faulted zone is a hose or a gun, you can remove the hose or gun and replace it with a hose or gun that is known to be good. If the fault disappears, then the problem is in the hose or gun, not inside the unit. As an alternative to using this procedure, you can refer to your hose or gun manual for instructions on checking the hose or gun RTD and replacing the gun RTD. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Place the unit s POWER switch in the off position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Check the RTD by measuring its resistance. Refer to Table B 2-7. If the RTD is defective, replace the RTD. If a hose RTD is defective, you must replace the hose. To replace a gun RTD, refer to your gun manual. To replace a tank RTD, refer to Replacing an RTD or a Thermostat in Repair Procedures. NOTE: Flex the hose when you are checking a hose RTD. Some hose RTDs exhibit problems intermittently. If the RTD is good, go to the next step.

29 B 2-27 Table B 2-7 Measuring RTD Resistance Quick Methods In-Depth Methods Using a surface-temperature sensing device, such as a thermocouple, measure the temperature of the RTD at or near the end of the RTD that is accessible. Then use an ohmmeter to measure its resistance (See Note A). See Figure B 2-6 and compare the resistance reading to the RTD s normal resistance at the known temperature. Roughly estimate the temperature of the RTD to the nearest 50 C (100 F). Use an ohmmeter to measure its resistance (See Note A). See Figure B 2-6 and compare the resistance reading to the RTD s normal resistance at the estimated temperature. Because RTDs usually fail open or closed, any resistance reading from approximately ohms strongly indicates that the RTD is good. Let the system cool down to room temperature. When the RTD has had time to reach room temperature, use an ohmmeter to measure its resistance (See Note A). See Figure B 2-6 and compare the resistance reading to the RTD s normal resistance at room temperature. Remove the RTD and heat it to a known temperature by using an oven or by placing it in boiling water (protect the wires and hold them above the water). Then use an ohmmeter to measure its resistance (See Note A). See Figure B 2-6 and compare the resistance reading to the RTD s normal resistance at the known temperature. NOTE A: If the faulted zone is a hose or gun, measure the RTD resistance at the hose or gun electrical plug. Refer to your hose or gun manual for a diagram of the electrical plug and for procedures for checking RTD resistance. Because the core elements of a hose are not accessible, you cannot use some of the methods described in this table to measure the temperature of a hose RTD. If the faulted zone is a tank, measure the resistance at pins 33 and 34 of the harness attached to connector XP2 on the control board.

30 B 2-28 Checking an RTD or RTD Circuit (contd.) 4. Check the continuity of the RTD circuit by measuring the RTD resistance at other points in the circuit. Refer to Table B 2-8 for the plug or harness pins for each check. For a gun RTD, you can check continuity at two points: first at the hose electrical plug and then at the harness connected to XP2 on the control board. For a hose RTD, you can check continuity at the hose electrical plug or at the harness connected to XP2 on the control board. See Figure B 2-4 for the location of XP2 on the control board. For the tank RTD, there are no further checks you can make: go to the next step. Zone with Faulted RTD Table B 2-8 Pins for Checking RTD Resistance Gun Electrical Plug Pins Hose Electrical Plug Pins Connector XP2 Harness Pins Gun 1 3 and 5 3 and 5 9 and 10 Hose 1 N/A 5 and 8 1 and 2 Gun 2 3 and 5 3 and 5 11 and 12 Hose 2 N/A 5 and 8 3 and 4 Gun 3 3 and 5 3 and 5 13 and 14 Hose 3 N/A 5 and 8 5 and 6 Gun 4 3 and 5 3 and 5 15 and 16 Hose 4 N/A 5 and 8 7 and 8 Gun 5 (See Note A) 3 and 5 3 and 5 25 and 26 Hose 5 (See Note A) N/A 5 and 8 29 and 30 Gun 6 (See Note A) 3 and 5 3 and 5 27 and 28 Hose 6 (See Note A) N/A 5 and 8 31 and 32 Tank N/A N/A 33 and 34 NOTE A: Some units can accept only four hoses and four guns. 5. If you find a continuity problem in the gun RTD circuit, replace the hose or replace the gun RTD harness inside the unit as appropriate. If you find a continuity problem in the hose RTD circuit, replace the hose RTD harness inside the unit. If you do not find a continuity problem, go to the next step. 6. Replace the control board or the control assembly. Refer to Replacing a Assembly Board or Replacing the Assembly in Repair Procedures.

31 B RESISTANCE IN OHMS C 32 C 54 C (50 F ) (90 F) (130 F ) 77C 99C 121C 143C 166C 188C 210C 232C (170 F ) (210 F ) (250 F ) (290 F ) (330 F ) (370 F ) (410 F ) (450 F ) Fig. B 2-5 RTD Resistance vs. Temperature

32 B Repair Procedures Use these procedures to replace control system components. You can use the parts list illustrations at the end of this section as a guide as you perform these procedures. Refer to the parts lists for the part numbers of any components to be replaced. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in personal injury or death. Allow only qualified personnel to perform these repair procedures. Observe all high-voltage indicators. Replacing a Fuse Follow this procedure to replace a fuse. A fuse may be secured by a vertical or horizontal fuse holder. WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Place the unit s POWER switch in the off position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. See Figure B 2-7 and use the following table to locate the fuse to be replaced.

33 B 2-31 Table B 2-9 Board Fuses Board Fuse for Fuse Numbers Power board Hose 1, gun 1 F1, F5 Hose 2, gun 2 Hose 3, gun 3 Hose 4, gun 4 power supply 480 VAC distribution board power, tank heater power 5/6 hose/gun board (5/6 hose/gun units only) Transformer (secondary winding) Hose 5, gun 5 Hose 6, gun 6 F2, F6 F3, F7 F4, F8 F9, F10 F1, F2, F3 F4 F1, F3 F2, F4 F1 F2 F1 F2 F3 F5 F6 F7 F8 F9 F10 F3 F4 F11 F12 2 F4 1 F1 F3 F4 F A Fig. B 2-6 Location of Fuses on Boards 1. Power board VAC distribution board 3. 5/6 hose/gun board

34 B 2-32 Replacing a Fuse (contd.) 4. See Figure B 2-7. Remove the fuse from the fuse holder and install the new fuse. Refer to the following table. Fuse Holder To Remove To Install Vertical 1. Press down on the fuse cap and turn it counterclockwise until you feel the cap release. Horizontal 2. Lift the cap and fuse from the connector. Lift the fuse from its two-station connector. 1. Pull the fuse from the cap and replace it with a new fuse. 2. Insert the cap and fuse into the fuse holder. Turn the fuse and cap clockwise and press down until you feel the cap lock into place. Press the replacement fuse into the two-station connector until the fuse snaps into place. 2 1 Fig. B 2-7 Fuse Holders 1. Vertical 2. Horizontal A 3. Close the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure.

35 B 2-33 Replacing a Assembly Board Use these procedures to replace the power board, control board, or display board. As an alternative, you can save time by replacing the entire control assembly. Refer to Replacing the Assembly. Preparation for Removal WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit, including input/output (I/O) lines. 1. Place the unit s POWER switch in the off position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Unscrew the support strap from the control-end frame and disconnect the electrical service from TB1 on the power board. Power Board Removal 1. If you have not already done so, complete Preparation for Removal. 2. Label or note all power board connections for later reference. NOTE: See the Parts section for an exploded drawing of the control assembly parts. The wiring diagram contained in the Wiring Diagrams section at the end of this manual may also be helpful. 3. Disconnect the voltage plug from X3 (and X4 if applicable) on the power board. NOTE: Replacement power boards do not have a voltage plug. You must keep the voltage plug from your old board. 4. Disconnect all harnesses, ribbon cables, and other connections from the power board.

36 1 B Remove the mounting hardware from the power board. CAUTION: Risk of equipment damage. Do not bend the XP1 connector pins. 6. Starting from the edge opposite the XP1 connector, carefully separate the power board from the control board. Take care not to bend the XP1 connector pins that join power board and control board. NOTE: The XP1 connector may remain attached to the power board. If it does, remove it and attach it to connector XP3 on the control board. NOTE: If the optional I/O board is connected to the control board on your unit, take care not to damage the I/O board as you remove the power board. Power Board Installation 1. Remove the new board from its static-safe container. Handle the board by its edges without touching any pins, wires, or circuitry. 2. See Figure B 2-8. Align XP1 on the new power board with the connector pins on the control board. Press the board into place, making sure the connector pins are properly inserted into their sockets Fig. B 2-8 Aligning the XP1 Connector Pins

37 B 2-35 Power Board Installation (contd.) 3. Install the mounting screws and lock washers you removed earlier. Be sure to use lock washers on the three screws located at the three ground pads on the power board. Tighten all screws to Nm (10 12 in.-lb). NOTE: See the Parts section for an exploded drawing of the control assembly parts. 4. Install the large triac (Q17) screw, which is to the left of TB1. Tighten the screw to Nm (7 8 in.-lb). 5. Install the two triac clamps and, starting with the center screw, tighten the securing screws to Nm (10 12 in.-lb). 6. Connect the voltage plug you kept from your old board to X3 (and X4 if applicable) on the power board. 7. Connect all other harnesses, ribbon cables, and other connections to the power board. 8. Go to System Restoration. Board Removal 1. If you have not already done so, complete Preparation for Removal. 2. Remove the power board. Refer to Power Board Removal. 3. Label or note all control board connections for later reference. NOTE: See the Parts section for an exploded drawing of the control assembly parts. The wiring diagram contained in the Wiring Diagrams section at the end of this manual may also be helpful. 4. Disconnect all harnesses, ribbon cables, and other connections from the control board. 5. Remove the mounting hardware from the control board. NOTE: If your unit has the optional I/O board, you must also disconnect this board from the control board. Refer to Series 3000V Input/Output Board in the Options section for instructions on I/O board removal. 6. Carefully separate the control board from the display board. Take care not to bend the XP4A connector pins that join the control and display boards. Retain the connector.

38 1 B 2-36 Board Installation 1. Remove the new board from its static-safe container. Handle the board by its edges without touching any pins, wires, or circuitry. 2. See Figure B 2-9. Align the XP4A connector pins (2) with the connector (1) on the display board, then carefully press the control board into place. 1 2 Fig. B 2-9 Aligning the XP4A Connector 1. XP4A connector 2. XP4A connector pins A 3. Reinstall the mounting hardware. Be sure to use lock washers on the two screws located at the two ground pads on the control board. Tighten all screws to Nm (10 12 in.-lb). NOTE: See the Parts section for an exploded drawing of the control assembly parts. 4. Connect all other harnesses, ribbon cables, and other connections to the control board. NOTE: If your unit has the optional I/O board, you must also connect this board to the control board. Refer to Series 3000V Input/Output Board in the Options section for instructions on I/O board installation. 5. Install the power board. Go to step 2 in Power Board Installation.

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G) Part B, Section 1 This section covers the following unit configurations. Model 3100 3400 3500 Voltage 1, 2 Pump Piston (E, F, or G) Manifold 4-Port (A) 6-Port (B or C) Control UniScan (1) B 1-0 B 1-1 Section

More information

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11 Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern

More information

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3860 3890 3930 3960 All Piston (D) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A

More information

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A Nordson Corporation OPERATOR S CARD P/N 052644A VL400 Melters Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

Part A, Section 1. Operation A4EN [3V - A - AAXV] V Issued 5/00. E 2000 Nordson Corporation All rights reserved

Part A, Section 1. Operation A4EN [3V - A - AAXV] V Issued 5/00. E 2000 Nordson Corporation All rights reserved Part A, ection 1 A1-0 A1-1 ection A 1 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. 1. Introduction

More information

Maintenance. Part A, Section 5. This section covers the following unit configurations.

Maintenance. Part A, Section 5. This section covers the following unit configurations. Part A, Section 5 This section covers the following unit configurations. Model 3100V 3400V 3830V 3860V 3890V 3930V Voltage 1, 2 Pump AC Gear (K or L) Manifold 4-Port (J)) Control Vista Standard (V) Vista

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with M-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

Recommended Spare Parts and Supplies

Recommended Spare Parts and Supplies Introduction O-1 Recommended Spare Parts and Supplies Major Assemblies Be sure to order the appropriate parts for your unit. To determine the features and options your unit has, refer to Explanation of

More information

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet Instruction Sheet Replacing a Gun RTD WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Hayward error codes and troubleshooting

Hayward error codes and troubleshooting http://waterheatertimer.org/intermatic-trippers-and-parts.html#pool 50 Hayward error codes and troubleshooting Section V. TROUBLESHOOTING http://www.hayward-pool.com/prd/in-ground-pool-manuals_10201_10551_14502_-1

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with C-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

3 Phase Smart Controller

3 Phase Smart Controller 3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838

More information

KEYLESS ENTRY SYSTEM

KEYLESS ENTRY SYSTEM KEYLESS ENTRY SYSTEM 1995 Volvo 850 1995 ACCESSORIES & EQUIPMENT Volvo Keyless Entry Systems 850 DESCRIPTION & OPERATION 850 models with central locking and factory installed alarm system can be equipped

More information

SAFE & SECURE ACTUATOR PRODUCT MANUAL

SAFE & SECURE ACTUATOR PRODUCT MANUAL INDELAC CONTROLS SAFE & SECURE ACTUATOR PRODUCT MANUAL Product Description: The Safe & Secure Series Actuator is a quarter turn Open/Close Actuator with Battery Backup Power ALL IN ONE! No more mounting

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE Duty B: Power Distribution (600V and below) B-03: Troubleshoot 480V System Issued 06/01/98 Task Preview Troubleshoot 480V System The 480V distribution

More information

Self-Testing Industrial Series

Self-Testing Industrial Series Series: AS-I (Maint.-Free) Self-Testing Industrial Series Emergency Lighting Equipment Instructions for INSTALLATION OPERATION SERVICE SPECIFICATIONS 1300650 1300654 1300666 1300754 1300823 1300886 Hubbell

More information

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater. 0 EDITION AIM MANUAL SUBMERSIBLE MORS APPLICATION INSTALLATION 60 Hz, Single-Phase and Three-Phase Motors franklinwater.com All Motors System Troubleshooting Motor Does Not Start A. No power or incorrect

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an out-in filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

T21 Thermal Differential Switch

T21 Thermal Differential Switch T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution

More information

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL E13 TEMPERATURE PROBE FAILURE E16 HIGH LIMIT 1 EXCEEDED A. TEMP Probe reading out of range. B. Bad Connection. C. Problem with the temperatur e measuring circuitry including the probe. High limit temperature

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3800V 3900V All Piston (F) 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Standard

More information

Spectron Industrial Series

Spectron Industrial Series 1300650 1300654 1300666 1300754 1300823 1300886 Table B Constant Value per Voltage System Wire Size (Maximum Voltage Drop 5%) System 6 Volt 12 Volt 24 Volt Wire Size #12 #10 #8 #6 #12 #10 #8 #6 #10 #12

More information

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for

More information

Preventive Maintenance for Pail Melters

Preventive Maintenance for Pail Melters Instruction Sheet P/N Preventive Maintenance for Pail Melters 1. Introduction These procedures are recommended in addition to the standard preventive maintenance. Use them to keep yourvista controlled

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 4000 Series ATS Automatic Open-Transition Transfer Switches D design 30 230A, J design 260 600A, H-design 800 1200A, G-design 1600 4000A, F-design 4000A DANGER is used in this manual

More information

SCR Power Controllers

SCR Power Controllers SCR Power Controllers Instruction Manual SCR POWER CONTROLLERS TABLE OF CONTENTS General Description and Specifications...1 Firing Modes....2 Installation and Wiring...4 Operation...9 Troubleshooting...15

More information

Electric, Heated, Plural Component Proportioner For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres.

Electric, Heated, Plural Component Proportioner For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres. Repair - Parts 309574M Electric, Heated, Plural Component Proportioner For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres. Important Safety Instructions: Read all

More information

GENERAL <ELECTRICAL>

GENERAL <ELECTRICAL> 00E-1 GROUP 00E GENERAL CONTENTS HARNESS CONNECTOR INSPECTION................................. 00E-2............. 00E-6................. 00E-6 TROUBLESHOOTING STEPS.......... 00E-6 INFORMATION

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

GENERAL <ELECTRICAL>

GENERAL <ELECTRICAL> 00E-1 GROUP 00E GENERAL CONTENTS HARNESS CONNECTOR INSPECTION................... 00E-2............. 00E-6................. 00E-6 TROUBLESHOOTING STEPS.......... 00E-6 INFORMATION FOR DIAGNOSIS.......

More information

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01 Section 9 NOTE: This section applies to applicators with CC200 modules. 9-0 Table of Contents i Table of Contents Section 9 1. Introduction............................................... 9-1 2. Specifications.............................................

More information

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 V3 TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 PREFACE This guide contains instructions for troubleshooting the Steffes Corporation room heating units: Models HPB 11, HPB

More information

CABINET REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS CABINET REEL OPERATING INSTRUCTIONS MODELS 15, 25, 40 & 60 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com

More information

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual Valcom Failsafe Unit 1620ESv2 SERIES Operation and Maintenance Manual Table of Contents Section Title Page 1. - Introduction.. 2. - Unpacking the Failsafe unit. 3. - Installation 3.1 - Auto / Timed UPS

More information

11-1 Electrical System NOTE: Table of Contents Electrical System

11-1 Electrical System NOTE: Table of Contents Electrical System Electrical System - Section Electrical System NOTE: This section applies to applicators with Universal C-style cordsets. Table of Contents Electrical System........................................... -

More information

Blow Off Valve Retrofit Kit

Blow Off Valve Retrofit Kit Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..

More information

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE SENS part number: 101037 Document revision: A Engineering change number: 105073 Date: 1/13/2006 1840 Industrial Circle

More information

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase. PD9100 / 9200 SERIES POWER CONVERTER OWNERS MANUAL PROGRESSIVE DYNAMICS, INC. POWER CONVERTER LIMITED WARRANTY I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power converter to be free from

More information

Repair - Parts M

Repair - Parts M Repair - Parts 312066M Electric, Heated, Plural Component Proportioner. For spraying polyurethane foam and polyurea coatings. For professional use only. Not for use in explosive atmospheres. ENG Important

More information

LED TROUBLESHOOTING. Controller Version L610 Rev 7M or newer (manufactured after 1/21/15)

LED TROUBLESHOOTING. Controller Version L610 Rev 7M or newer (manufactured after 1/21/15) LED TROUBLESHOOTING Controller Version L610 Rev 7M or newer (manufactured after 1/21/15) Last update 11/5/18 The purpose of this document is to help the airfield electrician troubleshoot the Lumacurve

More information

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6 Washer Tech Data Sheet This information is intended for Qualified Technicians Only. CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to its Envelope in the Product for Future

More information

LPT50BRD (8x11x3 Enclosure)

LPT50BRD (8x11x3 Enclosure) LPT50BRD (8x11x3 Enclosure) TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN The LPT50BRD is a field repairable switch. Warranty covers defective parts only.

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

Service Procedure # CDV-101

Service Procedure # CDV-101 TRW Automotive Commercial Steering Systems Service Procedure # CDV-101 TRW ColumnDrive Troubleshooting Guide March, 2007 NOTE Take appropriate safety measures before beginning this procedure. This TRW

More information

AUTOMATIC CONTROL ROLLING DOOR OPENER

AUTOMATIC CONTROL ROLLING DOOR OPENER AUTOMATIC CONTROL ROLLING DOOR OPENER INSTALLATION INSTRUCTION AUTOMATIC OBSTRUCT PHOTOELECTRIC BEAM ROLLING CODE SYSTEM AUTO CLOSE DOOR ANTI-THEFT SYSTEM INSTALLATION INSTRUCTION AND RDO OWNERS MANUAL

More information

Installing the Integral Platen Blow Off Valve

Installing the Integral Platen Blow Off Valve Instruction Sheet Installing the Integral Platen Blow Off Valve WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all

More information

ITS-50R TRANSFER SWITCH OWNER S MANUAL

ITS-50R TRANSFER SWITCH OWNER S MANUAL ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard

More information

TC1000 Service Manual SALES: CUSTOMER SERVICE:

TC1000 Service Manual SALES: CUSTOMER SERVICE: TC1000 Service Manual SALES: 800-278-3933 CUSTOMER SERVICE: 800-745-1373 Table of Contents Section Page I. Overview 2 II. Troubleshooting Tables 3 III. Maintenance Procedures Procedure 1 Removal and Reinstallation

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

Installing the Low Level Indicator (P/N or P/N )

Installing the Low Level Indicator (P/N or P/N ) Instruction Sheet Installing the Low Level Indicator (P/N 276 176 or P/N 276 4) 1. Introduction There are two Low Level indicator kits, one for flat bottomed tanks and one for the new finned tanks. P/N

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious

More information

Furnace Web Site FAQs. Pro Press 100 / Pro 100 / Pro 100 plus. Lift. Belt Noise

Furnace Web Site FAQs. Pro Press 100 / Pro 100 / Pro 100 plus. Lift. Belt Noise Furnace Web Site FAQs Pro Press 100 / Pro 100 / Pro 100 plus Lift Belt Noise A Worn belt Over time the belt may become dry or worn due to heat and travel. Replace the belt Tight If the belt was recently

More information

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

section-page Table 1. Transfer switching device ratings. Conditional short circuit current Operator s Manual 7000 Series ATS Automatic Transfer Switching Equipment D design 30 through 200 amperes TABLE OF CONTENTS section-page INSTALLATION... 1-1 Enclosures and Mounting... 1-1 Power Connections...

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power. Technical Information Gas Slide-In Range JGS8750ADB/S/W JGS8850ADB/Q/S/W Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this

More information

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D Nordson Corporation OPERATOR S CARD P/N 321 198D Select Series H-440 Hot Melt Dispensing Guns Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V Part B, Section 1 This section covers the following unit configurations. Model Voltage Pump Manifold Control 3100V 3400V 3500V 3700V All Piston (E) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Standard

More information

EB Conveyor Maintenance Guide

EB Conveyor Maintenance Guide EB Conveyor Maintenance Guide EN-0037 Rev A EB Conveyor Maintenance Guide www.qdraw.com Table of Contents Overview Page 3 Exploded View Of A Standard EB Conveyor Page 4 Preventative Maintenance Page 5

More information

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS? ARM V FDBK ENSURE MOTOR IS T ROTATING DURING POWER UP This fault can only happen in the first 3 seconds after power up. The processor looks at the armature voltage. The voltage needs to be near 0. Possible

More information

Transfer Switch GPTS 30

Transfer Switch GPTS 30 Transfer Switch GPTS 30 Owner s Manual Table of Contents Introduction 2 Installation 3 Operational Testing 7 Troubleshooting 8 Hi-Pot Testing 9 Generator Note 10 Medical Appliances 10 Caution 10 Warranty

More information

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

BLOWER VACUUM SWITCH FAILED OPEN

BLOWER VACUUM SWITCH FAILED OPEN F1 F1 AC BLOWER VACUUM SWITCH FAILED CLOSED AC BLOWER VACUUM SWITCH FAILED CLOSED UHS If the blower vacuum switch is closed before blower start-up, the control module will not start the blower. Pre-check

More information

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION SERIES 000/S-X MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION Publication S000X- VER045- For information on this product and other

More information

CHARGING SYSTEM 7.7 GENERAL TROUBLESHOOTING. Alternator. Voltage Regulator. Battery. Wiring. Voltage Regulator Inspection HOME

CHARGING SYSTEM 7.7 GENERAL TROUBLESHOOTING. Alternator. Voltage Regulator. Battery. Wiring. Voltage Regulator Inspection HOME CHARGING SYSTEM 7.7 GENERAL 8740 The charging system consists of the alternator and regulator. Charging system circuits are shown in Figure 7-5. Never install accessory wiring between battery post and

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

SP30 10:1 Piston Pump

SP30 10:1 Piston Pump Instruction Sheet P/N SP30 10:1 Piston Pump 1. Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and

More information

Power Distribution System User s Manual. Model: PDS-100

Power Distribution System User s Manual. Model: PDS-100 Power Distribution System User s Manual Model: PDS-0 Section Page Product Overview... 1 I) General Information... 2 II) Important Safety Information... 2 III) Installation... 3 A) Materials Provided...

More information

Old. Repair - Parts J

Old. Repair - Parts J Repair - Parts Old 311300J Hydraulic, Heated, Plural Component Proportioner For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres. Important Safety Instructions Read

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

AUTOMATIC SPRINKLER TIMER

AUTOMATIC SPRINKLER TIMER AUTOMATIC SPRINKLER TIMER Owner s Manual PRT-4 / PRT-6 For use with standard 24 VAC automatic sprinkler valves. These timers are designed for use in any 110 VAC /60 Hz ±10% AC outlet (240 VAC, 50 HZ for

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners YD360/480/600, YJ-30/-40/-50 and J30/40/50 YD Models 642546-UAI-A-080 GENERAL Standard operation

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

Modulating Furnace Information. Warning on Meter Setting - Read First!

Modulating Furnace Information. Warning on Meter Setting - Read First! Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56

More information

Service Manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta

Service Manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta Service W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta 438 9201-81/EN 06.42 Overview Safety precautions Technical data Machine presentation 1 2 3 4 5 Service instructions Machine components

More information

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates

More information

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual Easy Start 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526. www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

Transfer Switch TS-50. Owner s Manual

Transfer Switch TS-50. Owner s Manual Transfer Switch TS-50 Owner s Manual Table of Contents Introduction 2 Installation 2 Operational Testing 7 Troubleshooting 7 Hi-Pot Testing 8 Generator Note 9 Medical Appliances 10 Caution 10 Disclaimer

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 www.kenco-eng.com e-mail: info@kenco-eng.com SERIES KTD THERMAL DIFFERENTIAL FLOW/LEVEL SWITCH INSTALLATION

More information

Installation Instructions for Series 3100V Low Level Indicator

Installation Instructions for Series 3100V Low Level Indicator Instruction Sheet P/N Installation Instructions for Series 3100V Low Level Indicator WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Owner and Operating Manual for

Owner and Operating Manual for Owner and Operating Manual for 120VAC Manual Control 12VDC Solar Battery Manual Control 120VAC Remote Control 12VDC Solar Battery Remote Control GEN2 Remote Versions Only Boat Lifts Please read this manual

More information

Series 3900/M Pump Retrofit Kit

Series 3900/M Pump Retrofit Kit Instruction Sheet P/N Series 900/M Pump Retrofit Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

SUN ELECTRONIC SYSTEMS EC1X HEAT/COOL TROUBLESHOOTING GUIDE

SUN ELECTRONIC SYSTEMS EC1X HEAT/COOL TROUBLESHOOTING GUIDE SUN ELECTRONIC SYSTEMS EC1X HEAT/COOL TROUBLESHOOTING GUIDE 062013 COVERS MODELS EC1x SUN ELECTRONIC SYSTEMS, INC. Tel: 321-383-9400 1845 Shepard Drive Fax: 321-383-9412 Titusville Florida Email:info@sunelectronics.com

More information

Automated Control Electronics (ACE ) System Operation and Diagnostics

Automated Control Electronics (ACE ) System Operation and Diagnostics Commercial Products Automated Control Electronics (ACE ) System Operation and Diagnostics PART NO. 98962SL This page is intentionally blank. Table of Contents Introduction... 1 Controller Operation and

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS ELECTRIC FENCE ENERGIZER MODEL 950 SERVICE MANUAL Service Manual for OLLI 950 Page 1/16 Date 20.10.2014 Table of Contents...1 1. IMPORTANT SAFETY INSTRUCTIONS...2 2. SPECIFICATIONS...3 3. CONSTRUCTION...4

More information

Section 7 - Troubleshooting Guide

Section 7 - Troubleshooting Guide Section 7 - Troubleshooting Guide Section 7 - Troubleshooting Guide IMPORTANT While this troubleshooting guide provides information to aid in troubleshooting problems with the range, it does not contain

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information