Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)

Size: px
Start display at page:

Download "Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)"

Transcription

1 Part B, Section 1 This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G) Manifold 4-Port (A) 6-Port (B or C) Control UniScan (1)

2 B 1-0

3 B 1-1 Section B 1 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. 1. Introduction This section includes UniScan control system troubleshooting procedures and repair procedures. Obvious causes of problems, such as broken wires, are generally not included in the troubleshooting procedures. Refer to the Parts section for the part number of any component that needs to be replaced. If you try all the suggestions in this section and still cannot solve the problem, call your Nordson representative for assistance. Refer to the Pump section for adhesive application troubleshooting procedures and for troubleshooting procedures and repair procedures for the melter s pump, motor (if present), and manifold assemblies. For hose or gun troubleshooting, refer to your hose or gun manual. The following sections of this manual contain additional information on the control system: Overview includes an overview of the control system. Installation includes procedures for making the parent machine interlock (PMI) and fault output contact connections, connecting electrical service, and setting up the control system for your operation. Operation includes procedures for operating and monitoring the control panel. Schematics includes a set of schematics for your system. Refer to the Options section for troubleshooting, repair, and parts information for the following options: Electric line filter

4 B Overview of the Control System The UniScan control system determines how your melter functions and the temperatures at which the tank, hoses, and guns operate. The control system includes several printed circuit boards (hereafter referred to as boards) and other components that you should be familiar with to safely troubleshoot and repair your melter. See Figure B A Fig. B 1-1 Standard UniScan Components 1. Main control panel and board 3. Hose/gun power modules 4. Tank power module 2. Control-end frame

5 B Troubleshooting Tables These troubleshooting tables describe the kinds of control system problems you may encounter and provide corrective actions for handling those problems. When necessary, the tables refer to more detailed troubleshooting procedures. Refer to the appropriate troubleshooting table for the type of problem you are experiencing: Melter Not Powering On Circuit Breaker Trips or Will Not Stay On Zone Not Heating Indicating a Fault Opening and Closing the Electrical Enclosure The electrical enclosure must be opened before you can proceed with many of the procedures in this section. Follow this procedure whenever you are instructed to open or close the electrical enclosure. 1. Place the melter circuit breaker in the OFF position. 2. See Figure B 1-2. To open the the electrical enclosure: a. Remove the electrical enclosure lid (1) and disconnect the ground wire. b. Loosen the two captive screws (2) near the top of melter (on either side of the control-end frame) and carefully lower the frame (3). 1 3 Fig. B 1-2 Opening the Electrical Enclosure 1. Electrical enclosure lid 3. Control-end frame 2. Captive screw A

6 B 1-4 Opening and Closing the Electrical Enclosure (contd.) 3. To close the electrical enclosure: a. Carefully raise the control-end frame and secure it with the captive screws. b. Reconnect any ground wires that were disconnected. c. Reinstall and secure the electrical enclosure lid. Melter Not Powering On If your melter will not power on, use this troubleshooting table. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in equipment damage, personal injury, or death. Allow only qualified personnel to perform electrical troubleshooting. Observe all high voltage indicators. Problem Possible Cause Corrective Action Circuit breaker in ON position but melter will not turn on No input power Blown fuse on main control board Failed circuit breaker Make sure the power is turned on at your branch circuit disconnect switch and that you are supplying the proper voltage to the melter. If necessary, refer to Making the Electrical Service Connections in the Installation section. Check the two 1 amp fuses on the lower part of the main control board for continuity. Replace if necessary. Check the voltage at TB1 (located on the center frame) and at TB2 (located under the tank power module). If there is sufficient voltage between each leg of service at TB1 and little or no voltage between wires 4 and 5 or wires 5 and 6 at TB2, replace the circuit breaker. Refer to Replacing the Circuit Breaker in Repair Procedures.

7 B 1-5 Circuit Breaker Trips or Will Not Stay On If the circuit breaker trips off or will not stay on, use this troubleshooting table. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in equipment damage, personal injury, or death. Allow only qualified personnel to perform electrical troubleshooting. Observe all high voltage indicators. Problem Possible Cause Corrective Action 1. Circuit breaker trips repeatedly (no fault condition indicated) 2. Circuit breaker trips intermittently (no fault condition indicated) Tank overtemperature thermostat tripped circuit breaker Failed circuit breaker or failed shutdown relay on main control board Overcurrent or short circuit Electrical noise from other equipment in area Disconnect the overtemperature thermostat (close-on-rise). If the circuit breaker holds when the thermostat is disconnected, replace the thermostat. Do not operate the melter unless the thermostat is connected. Refer to Replacing a Tank Thermostat or RTD. Disconnect and lock out power to melter. Disconnect wire 7 on the back of the circuit breaker and wrap the terminal on the end of the wire with electrical tape. Restore power to the melter. Turn the circuit breaker on. If the circuit breaker does not hold, replace the circuit breaker. If the circuit breaker holds, replace the main control board. Refer to Replacing the Circuit Breaker or Replacing a Component in Repair Procedures. Visually check the wiring inside the electrical enclosure. Look for incorrect connections or loose or crossed wires. Check all circuits for a line-to-line or line-to-ground short. Check for electrical noise generated by other equipment in the area. Other motor drives are often the source of the electrical noise. Make sure the melter and the parent machine are on the same ground plane. Check the continuity between the frame of the melter and the frame of the parent machine. If there is no continuity or if there is high resistance, electrically ground the melter to the parent machine using as short a length of braided cable as possible.

8 B 1-6 Zone Not Heating If a tank, hose, or gun does not heat, use this troubleshooting table. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in equipment damage, personal injury, or death. Allow only qualified personnel to perform electrical troubleshooting. Observe all high voltage indicators. Problem Possible Cause Corrective Action Tank, hose, or gun does not heat or underheats Zone temperature setpoint too low Insufficient input voltage Blown fuse on power module High resistance on heater circuit caused by loose or oxidized heater connection or failed component Make sure the temperature setpoint is high enough. Make sure you are supplying the proper voltage to the melter. Refer to Making the Electrical Service Connections in the Installation Section. Remove the electrical enclosure lid and examine the red control LED and the heater power neon on the power module for the nonheating component. If the red control LED is on and the neon is off, check the continuity of the fuses on the power module. If a fuse is open, replace the fuse. If a fuse is okay, replace the power module. Refer to Replacing a Component in Repair Procedures. Remove the electrical enclosure lid and examine the red control LED and the heater power neon on the power module for the nonheating component. If both lights are on, check all connections to the heater circuit, including hose and gun plugs. Tighten loose connections. If the connections are okay, replace the heater or defective component. To verify that a heater has the correct resistance, refer to Note A and use the wiring diagram in the Schematics section. Refer to the gun manual for instructions on replacing a gun heater. You cannot replace a hose heater or a tank heater you must replace the hose or tank. Refer to the Tank section for procedures on tank replacement.

9 B 1-7 Problem Possible Cause Corrective Action Tank, hose, or gun does not heat or underheats (contd.) RTD circuit resistance high Failed ribbon cable in the circuit of the problem zone Remove the electrical enclosure lid and examine the red control LED and the heater power neon on the power module for the non-heating component. If the red control LED is off and the neon is off, check the resistance on the RTD circuit for that zone. Refer to Checking an RTD or RTD Circuit in Troubleshooting Procedures. Remove the electrical enclosure lid and examine the red control LED and the heater power neon on the power module for the nonheating component. If the red control LED is off, check the ribbon cable. Refer to Checking a Ribbon Cable in Troubleshooting Procedures. Replace the ribbon cable if it is defective. If the ribbon cable is okay, replace the main control board and the display board. NOTE A: To determine what the resistance of a tank heater should be, refer to Table B 1-1. To determine what the resistance of a hose or gun heater should be, use the following formula: V 2 W= R (where V=voltage, W=wattage, and R=resistance). To determine the voltage of a gun heater, look at the gun identification plate or the heater cartridge. To determine the voltage of a hose heater, look at the hose tag. Table B 1-1 Tank Heater Resistance Data Melter Component Resistance 3100 Tank Tank Tank

10 B 1-8 Indicating a Fault When a tank, hose, or gun fault occurs, the red FAULT light next to the circuit breaker turns on the melter shuts down after a two-minute time delay After the two-minute time delay elapses, the melter will turn off. You can reset the circuit breaker immediately to obtain an additional two minutes of troubleshooting time. This may be repeated any number of times unless the temperature of the tank wall reaches 260 C (500 F). When the tank wall temperature exceeds 260 C (500 F), the tank overtemperature thermostat closes, causing the circuit breaker to trip. The circuit breaker cannot be reset until the tank wall temperature falls below 260 C (500 F). NOTE: Each heated component (each hose, each gun, and the tank) is referred to as a heated zone or zone. Zones may also be referred to as channels. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in equipment damage, personal injury, or death. Allow only qualified personnel to perform electrical troubleshooting. Observe all high voltage indicators. Problem Possible Cause Corrective Action FAULT light turns on Shorted RTD, RTD circuit, or ribbon cable in the problem zone Shorted power module Check the RTD for a shorted condition. If the RTD is defective, replace it. If the RTD is okay, check the wiring and ribbon cable for a shorted condition. Check for a shorted power module. Observe the red control LED and the power neon on the power module. If the red control LED is off and the power neon is on, replace the power module (the switching component on the power module board is not turning off). Refer to Checking the Power Module Lights in Troubleshooting Procedures.

11 B Troubleshooting Procedures Use these procedures as directed in the troubleshooting tables to further troubleshoot control system problems. Checking an RTD or RTD Circuit NOTE: If the faulted zone is a hose or a gun, you can disconnect the hose or gun at that zone and connect a hose or gun that is known to be good, or you can move the faulted hose or gun to another connection. If the fault disappears or follows the hose or gun, then you will know that the problem is in the hose or gun, not inside the melter. As an alternative to using this procedure, refer to your hose or gun manual for instructions on checking the hose or gun RTD and replacing the RTD. 1. Turn off the melter, disconnect and lock out electrical power to the melter at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Check the RTD resistance. To check the tank RTD, use a surface-temperature sensing device, such as a pyrometer, to measure the temperature of the heated zone at or near the RTD. Then measure the RTD s resistance. NOTE: If the faulted zone is a hose or gun, measure the RTD resistance at the hose or gun electrical plug. Refer to your hose or gun manual for a diagram of the electrical plug and for procedures for checking RTD resistance. Because the core elements of a hose are not accessible, the easiest method to check the actual temperature of a hose is to secure the end of the hose over a waste container. Then use a pyrometer with an immersion probe and measure the temperature of the adhesive as it is being discarded into the waste container. 4. Compare the RTD s temperature and resistance reading to the normal resistance range shown in Figure B 1-3. If the RTD resistance is significantly outside the normal range, replace the RTD. If a hose RTD is defective, you must replace the hose. To replace a gun RTD, refer to your gun manual. To replace a tank RTD, refer to Replacing an RTD or a Thermostat in Repair Procedures. If the RTD resistance is within the normal range, go to the next step. NOTE: For hose resistance data, refer to your hose manual.

12 B 1-10 Checking an RTD or RTD Circuit (contd.) 5. Check the continuity of the RTD circuit by measuring the RTD resistance at other points in the circuit. Refer to the Schematics section. Note that intermittent connections are the most difficult to troubleshoot since they are not always evident during continuity testing. 6. If you find a continuity problem in the RTD circuit, replace or repair the defective component as appropriate. If you do not find a continuity problem, replace the main control board. Refer to Replacing the Main Control Board in Repair Procedures RTD RESISTANCE IN OHMS C 32 C 54 C 77 C 99 C 121 C 143 C 166 C 188 C 210 C 232 C (50 F ) (90 F ) (130 F ) (170 F ) (210 F ) (250 F ) (290 F ) (330 F ) (370 F ) (410 F ) (450 F ) RTD TEMPERATURE Fig. B 1-3 RTD Resistance vs. RTD Temperature

13 B 1-11 Checking a Ribbon Cable Follow this procedure to check the continuity of a ribbon cable. 1. Turn off the melter, disconnect and lock out electrical power to the melter at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Disconnect both ends of the suspect ribbon cable. 4. Place a small-gauge solid wire into corresponding positions on the connectors at each end of the ribbon cable. Pin 1 is usually indicated by an arrow or some other distinguishing mark on the connector housing. 5. Check the resistance. The resistance should be less than 1 ohm at each position. Flex the cable to check for a possible intermittent open circuit. For a complete test, check for continuity between each position and its adjacent positions at each end of the ribbon cable. If continuity is detected between any two adjacent positions, then the ribbon cable is defective. NOTE: A ribbon cable may pass a continuity test but still be defective due to an undetected intermittent open circuit. You may need a fast-responding meter to detect an intermittent open circuit.

14 B 1-12 Checking the Power Module Lights The power modules supply power to a hose, gun, or tank heater when a low-voltage signal is received from the main control board. There can be up to two four-channel power modules for the hose and gun heaters. There is a one-channel power module for the tank heater. Each power module has diagnostic lights to assist you in troubleshooting temperature problems. Follow this procedure to check the power module lights. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in equipment damage, personal injury, or death. Allow only qualified personnel to perform electrical troubleshooting. Observe all high voltage indicators. 1. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 2. Observe the power module for the problem zone. See Figure B 1-4 and refer to Table B 1-2 to interpret the power module lights. FAULT Light on Control Panel Red Control LED on Power Module Table B 1-2 Checking the Power Module Lights Heater Power Neon on Power Module Condition Off Off Off The zone is above the temperature setpoint and is cooling. Off On On The zone is below the temperature setpoint and is heating, or, if the temperature does not increase, the heater circuit is open. Off Flashing Flashing The zone is at the temperature setpoint. Off On Off The power circuit to the heater is open. Check the fuses. Off Off On The power circuit to the heater is not turning off. Replace the power module. NOTE: This is a normal indication for a disconnected hose or gun zone. On On On The RTD is shorted. On Off On There is an overtemperature condition because the power module is shorted on. A four-channel power module will also display this sequence of lights if the zone is turned on but the hose or gun is disconnected electrically.

15 B 1-13 TANK LED TANK NEON GUN 1 LED AND NEON HOSE 1 LED AND NEON GUN 2 LED AND NEON HOSE 2 LED AND NEON GUN 3 LED AND NEON HOSE 3 LED AND NEON GUN 4 LED AND NEON HOSE 4 LED AND NEON A Fig. B 1-4 Location of Indicator Lights on Power Modules 5. Repair Procedures Troubleshooting procedures may identify failed components. Use these repair procedures to replace failed components. Refer to the Parts section to locate and order replacement parts and service kits. You can also use the parts drawings as a guide as you perform the following repair procedures. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in equipment damage, personal injury, or death. Allow only qualified personnel to perform electrical repairs. Observe all high voltage indicators. Replacing the Tank RTD or Thermostat 1. Turn off the melter, disconnect and lock out electrical power to the melter at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Remove the electrical enclosure lid and disconnect the ground wire. 3. Remove the front cover and disconnect the ground wire. 4. Locate the tank RTD and overtemperature thermostat behind the cutaway in the tank insulation (above the manifold filter).

16 B 1-14 RTD Replacement 1. Disconnect the RTD plug. 2. See Figure B 1-5. Follow these steps to replace the RTD: a. Remove the RTD retainer plate (2) and then remove the RTD (1). b. Coat the new RTD with thermal compound and insert it into the tank. c. Reinstall the RTD retainer plate in the orientation shown in Figure B Reposition the insulation over the tank RTD and thermostat. It is not necessary to tape the insulation, but if you do be sure to use high-temperature tape. 4. Connect the RTD plug. Î ÎÎ ÎÎ ÏÏÏ ÎÎÎÎ ÎÎ ÏÏ ÎÎ A Fig. B 1-5 Replacing the Tank RTD 1. RTD 2. Retainer plate

17 B 1-15 Thermostat Replacement 1. Disconnect the thermostat plug. 2. See Figure B 1-6. Follow these steps to replace the thermostat: a. Push back the rubber insulator and remove the screws that secure the thermostat to the tank. b. Remove the old thermostat and install a new one. c. Push the rubber insulator back over the thermostat. Î ÎÎ Î ÏÏÏÎÎ ÎÎÏÏÏÏ ÎÎ Î ÏÏÎÎ A Fig. B 1-6 Replacing the Tank Thermostat 3. Reposition the insulation over the tank RTD and thermostat. It is not necessary to tape the insulation, but if you do be sure to use high-temperature tape. 4. Connect the thermostat plug. System Restoration 1. Reinstall the front cover and attach the ground wire. 2. Reinstall the electrical enclosure lid and attach the ground wire. 3. Restore power to the melter and resume normal operation.

18 B 1-16 Replacing a Component Follow this procedure to replace any control system component. The control system components include control panels, and power modules. 1. Turn off the melter, disconnect and lock out electrical power to the melter at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Attach a static wrist strap from your wrist to the ground stud on the base of the melter. 4. Refer to the illustrations in Control Assembly Parts in the Parts section. Disconnect all ribbon cables and other connections from the component you are replacing. Mark or label the connections for later reference. 5. Remove the hardware that secures the component; then carefully remove the component. 6. Install the new component using the hardware you removed earlier. 7. Connect all ribbon cables and other connections to the new component. 8. If you are installing a main control board, make sure the time delay switches are set properly. Refer to Changing the Time Delay Setting in the Installation section. 9. Close the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 10. Restore power to the melter and resume normal operation. Replacing the Circuit Breaker Follow this procedure to replace the circuit breaker. 1. Turn off the melter, disconnect and lock out electrical power to the melter at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Open the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 3. Remove the front cover and disconnect the ground wire.

19 B See Figure B 1-7. Remove the screws (4) that attach the circuit breaker to the base. 5. Remove the wire ties to the cable clamp (1) and push the boot (2) from the circuit breaker. 6. Label the wires connected to the circuit breaker (3) and disconnect them from the terminals A Fig. B 1-7 Circuit Breaker Components 1. Cable clamp 2. Boot 3. Circuit breaker 4. Screws 5. Lights 7. Connect all wires to the new circuit breaker and push the boot over the circuit breaker. Attach a new wire tie around the wires at the back of the boot to prevent the boot from sliding off the circuit breaker and exposing the terminals. If necessary, refer to the Schematics section. 8. Attach the circuit breaker assembly to the base with the screws you removed earlier. 9. Install the front cover and connect the ground wires. 10. Close the electrical enclosure. Refer to Opening and Closing the Electrical Enclosure. 11. Restore power to the melter and resume normal operation.

20 B 1-18

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part B, Section 2 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, G) Manifold 4-Port (A) 6-Port (B, C) 2-Port (S, T) Vista Standard (V) B 2-0

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with M-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11 Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with C-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3860 3890 3930 3960 All Piston (D) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista

More information

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0

More information

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00 Part B, Section 5 This section covers the following unit configurations Model 5 Voltage. Pump Piston (E,) Manifold -Port (A) Control UniScan Nordson Corporation Issued / B 5- Issued / 999 Nordson Corporation

More information

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A Nordson Corporation OPERATOR S CARD P/N 052644A VL400 Melters Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet Instruction Sheet Replacing a Gun RTD WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6 Part B, Section 5 Model 500 Voltage, Pump Piston (E) Manifold -Port (B or C) -Port (S or T) Control MultiScan (M) 000Nordson Corporation -000 Issued /00 B 5-0 -000 Issued /00 000 Nordson Corporation B

More information

11-1 Electrical System NOTE: Table of Contents Electrical System

11-1 Electrical System NOTE: Table of Contents Electrical System Electrical System - Section Electrical System NOTE: This section applies to applicators with Universal C-style cordsets. Table of Contents Electrical System........................................... -

More information

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01 Section 9 NOTE: This section applies to applicators with CC200 modules. 9-0 Table of Contents i Table of Contents Section 9 1. Introduction............................................... 9-1 2. Specifications.............................................

More information

Part A, Section 1. Operation A4EN [3V - A - AAXV] V Issued 5/00. E 2000 Nordson Corporation All rights reserved

Part A, Section 1. Operation A4EN [3V - A - AAXV] V Issued 5/00. E 2000 Nordson Corporation All rights reserved Part A, ection 1 A1-0 A1-1 ection A 1 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. 1. Introduction

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an out-in filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

Troubleshooting Title of Bulletin guide for single phase GFCIs Manual machines

Troubleshooting Title of Bulletin guide for single phase GFCIs Manual machines Bulletin Number: TB084 Type of Bulletin: Informational Products Affected: Manual TracStars: 250/28, 412/618, 500 series II and III. Rolling 412/618 Date of Notification: October 22, 2012 Reason for Bulletin

More information

Modulating Furnace Information. Warning on Meter Setting - Read First!

Modulating Furnace Information. Warning on Meter Setting - Read First! Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56

More information

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE Duty B: Power Distribution (600V and below) B-03: Troubleshoot 480V System Issued 06/01/98 Task Preview Troubleshoot 480V System The 480V distribution

More information

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual Valcom Failsafe Unit 1620ESv2 SERIES Operation and Maintenance Manual Table of Contents Section Title Page 1. - Introduction.. 2. - Unpacking the Failsafe unit. 3. - Installation 3.1 - Auto / Timed UPS

More information

One-Gun Add-On Kit For Smart-Coat Controllers

One-Gun Add-On Kit For Smart-Coat Controllers Instruction Sheet P/N One-Gun Add-On Kit For Smart-Coat Controllers 1. Introduction This document contains procedures for installing a one-gun add-on kit to your Smart-Coat Controller. For additional information,

More information

ADVANCED PID TROUBLESHOOTING

ADVANCED PID TROUBLESHOOTING ADVANCED PID TROUBLESHOOTING August 29, 2016 A KEY POINT If the drive is telling you something via a Fault, then the problem is probably not the drive. The drive is recognizing a fault and telling you

More information

Notdson MANUAL REFILL/MELTER RETROFIT KIT. SUPERSEDES -i I/ f3 NORDSON CORPORATION 1984 All Rights Reserved

Notdson MANUAL REFILL/MELTER RETROFIT KIT. SUPERSEDES -i I/ f3 NORDSON CORPORATION 1984 All Rights Reserved Packagmg and Assembly Division Notdson Atlanta, Georgia TECHNICAL PUB ICATION 5 9-3 - MANUAL 59-3 AUTOMATIC HOT MELT REFILL/MELTER RETROFIT KIT ELECTRONIC LEVEL CONTROL MODEL ISSUED 984 Publication No.

More information

Blow Off Valve Retrofit Kit

Blow Off Valve Retrofit Kit Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..

More information

RigMaster Power Service and Repair Manual Document # S901009

RigMaster Power Service and Repair Manual Document # S901009 Document # S901009 WARNING The following procedures present hazards which can result in injury or death. Only persons qualified to carry out electrical and mechanical servicing should undertake this work.

More information

Maintenance. Part A, Section 5. This section covers the following unit configurations.

Maintenance. Part A, Section 5. This section covers the following unit configurations. Part A, Section 5 This section covers the following unit configurations. Model 3100V 3400V 3830V 3860V 3890V 3930V Voltage 1, 2 Pump AC Gear (K or L) Manifold 4-Port (J)) Control Vista Standard (V) Vista

More information

Hayward error codes and troubleshooting

Hayward error codes and troubleshooting http://waterheatertimer.org/intermatic-trippers-and-parts.html#pool 50 Hayward error codes and troubleshooting Section V. TROUBLESHOOTING http://www.hayward-pool.com/prd/in-ground-pool-manuals_10201_10551_14502_-1

More information

COOKSON OWNER'S MANUAL

COOKSON OWNER'S MANUAL COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8

More information

Installation Instructions for Series 3100V Low Level Indicator

Installation Instructions for Series 3100V Low Level Indicator Instruction Sheet P/N Installation Instructions for Series 3100V Low Level Indicator WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

1333 (SERIES B & C) TROUBLESHOOTING GUIDE 1333 (SERIES B & C) TROUBLESHOOTING GUIDE Preventive Maintenance: Problems with Your Drive? Bulletin 1333 is convection or fan cooled by air flowing through the heat sink slots. The slots must never be

More information

COMPONENT ACCESS. If no voltage is present, check wiring to the board. If voltage is present, and brewer does not power on, replace board.

COMPONENT ACCESS. If no voltage is present, check wiring to the board. If voltage is present, and brewer does not power on, replace board. COMPONENT ACCESS This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining

More information

SP30 10:1 Piston Pump

SP30 10:1 Piston Pump Instruction Sheet P/N SP30 10:1 Piston Pump 1. Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners YD360/480/600, YJ-30/-40/-50 and J30/40/50 YD Models 642546-UAI-A-080 GENERAL Standard operation

More information

RE22 Airbag Systems, Side

RE22 Airbag Systems, Side Uniform Procedures For Collision Repair UPCR RE22 Airbag Systems, Side 1. Description This procedure describes methods for the repair, replacement, inspection, and testing of side airbag systems. Side

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information

More information

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions DEH 40026 Installation Instructions g ProTrip Conversion Kits For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION GE Conversion Kits are designed for upgrading existing

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D Nordson Corporation OPERATOR S CARD P/N 321 198D Select Series H-440 Hot Melt Dispensing Guns Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

UNIQUE FEATURES: 1085 SW 15 TH AVE. SUITE 2

UNIQUE FEATURES: 1085 SW 15 TH AVE. SUITE 2 Universal Systems is one of the world s premier manufacturers of hot melt adhesive systems and custom components. We manufacture a complete line of hot melt products that include auto fill hot melt units,

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

DESCRIPTION & OPERATION

DESCRIPTION & OPERATION DESCRIPTION & OPERATION 1998-99 SUSPENSION Electronic - Real Time Damping - Corvette The Real Time Damping (RTD) system automatically controls vehicle ride by independently controlling a damper solenoid

More information

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL INSTRUCTION MANUAL IM245 RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL SAFETY INSTRUCTIONS TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR

More information

Preventive Maintenance for Pail Melters

Preventive Maintenance for Pail Melters Instruction Sheet P/N Preventive Maintenance for Pail Melters 1. Introduction These procedures are recommended in addition to the standard preventive maintenance. Use them to keep yourvista controlled

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

BL7000 SYSTEM OPERATING MANUAL

BL7000 SYSTEM OPERATING MANUAL BL7000 SYSTEM OPERATING MANUAL REV 2.0 208 / 230V COPYRIGHT 1995 Xenotech, Inc. PAGE 1 POWER INPUT CONNECTOR WIRING INSTRUCTIONS THE INPUT POWER REQUIREMENTS FOR A 7 KW POWER SUPPLY ARE AS FOLLOWS. VOLTAGE

More information

T21 Thermal Differential Switch

T21 Thermal Differential Switch T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution

More information

Upgrading the Sure Coat Modular Gun Control System

Upgrading the Sure Coat Modular Gun Control System Instruction Sheet P/N 007365B Upgrading the Sure Coat Modular Gun Control System WARNING: Read the Safety section in the Sure Coat Modular Gun Control System manual before performing any of the following

More information

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL 12285 E. MAIN ST. MARSHALL, IL 62441 PHONE: 217-826-6352 FAX: 217-826-8551 WEB SITE: www.yargus.com 1 OPENING SCREEN The OPENING SCREEN is the screen that the

More information

BLOWER VACUUM SWITCH FAILED OPEN

BLOWER VACUUM SWITCH FAILED OPEN F1 F1 AC BLOWER VACUUM SWITCH FAILED CLOSED AC BLOWER VACUUM SWITCH FAILED CLOSED UHS If the blower vacuum switch is closed before blower start-up, the control module will not start the blower. Pre-check

More information

N1387 Series Troubleshooting Guide for N Alternators

N1387 Series Troubleshooting Guide for N Alternators N1387 Series Troubleshooting Guide for N1387-1 Alternators Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning

More information

EQUALIZER SYSTEMS County Road 3 Elkhart, IN Fax

EQUALIZER SYSTEMS County Road 3 Elkhart, IN Fax EQUALIZER SYSTEMS 55169 County Road 3 Elkhart, IN 46515 800-846-9659 574-264-3437 Fax 574-266-6083 SERVICE INFORMATION FOR GULF STREAM COACH Many of the perceived problems with leveling and slide systems

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with a threaded filter. Table of Contents Filter... 10-1 Introduction... 10-3 Filter Overview... 10-3 Filter Service... 10-4 Relieving

More information

Recommended Spare Parts and Supplies

Recommended Spare Parts and Supplies Introduction O-1 Recommended Spare Parts and Supplies Major Assemblies Be sure to order the appropriate parts for your unit. To determine the features and options your unit has, refer to Explanation of

More information

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide 8/28/00 TROUBLESHOOTER S GUIDE PROBLEM CAUSE SOLUTION Insufficient water flow to chlorinator Check water flow through Flow Controller

More information

Model No. SB1B-14 Linear Standby Regulator. B & C Specialty Products P.O. Box B Newton, KS (316)

Model No. SB1B-14 Linear Standby Regulator. B & C Specialty Products P.O. Box B Newton, KS (316) Installation Instructions for Model No. SB1B-14 Linear Standby Regulator With Over-Voltage Protection B & C Specialty Products P.O. Box B Newton, KS 67114 (316) 283-8000 SB1B-14_Install, Rev. A (12/12/14)

More information

2002 ENGINE PERFORMANCE. Self-Diagnostics - RAV4. Before performing testing procedures, check for any related Technical Service Bulletins (TSBs).

2002 ENGINE PERFORMANCE. Self-Diagnostics - RAV4. Before performing testing procedures, check for any related Technical Service Bulletins (TSBs). 2002 ENGINE PERFORMANCE Self-Diagnostics - RAV4 INTRODUCTION NOTE: Before performing testing procedures, check for any related Technical Service Bulletins (TSBs). To properly diagnosis and repair this

More information

ONE TOUCH CONTROL BOX

ONE TOUCH CONTROL BOX ONE TOUCH CONTROL BOX CONVERSION KIT INSTRUCTIONS REMOVAL, INSTALLATION, OPERATION, AND REMOTE CONTROL PROGRAMMING THUNDERSTONE PART #101322 REVISION A JULY 14 TH 2016 2 P a g e INSTALLING THE THUNDER

More information

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL E13 TEMPERATURE PROBE FAILURE E16 HIGH LIMIT 1 EXCEEDED A. TEMP Probe reading out of range. B. Bad Connection. C. Problem with the temperatur e measuring circuitry including the probe. High limit temperature

More information

Technical Data for 3700 Series Melters

Technical Data for 3700 Series Melters Part D, Section 1 This section covers the following unit configurations. Model 3700 Voltage All Pump All Manifold All Control All 1-3000 D1EN-01-[37-TD]- D 1-0 D1EN-01-[37-TD]- 1-3000 D 1-1 Section D 1

More information

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL The High Performance Company Table Of Contents: page Safety instructions: Definitions of Terms... 2 Introduction principle of operation...

More information

Fault Code 34 - Weak Battery Voltage Supply

Fault Code 34 - Weak Battery Voltage Supply Fault Code 34 - Weak Battery Voltage Supply Fault Isolation Procedures TRTS0930 Fault Code 34 - Weak Battery Voltage Supply J1587: MID 130 PID 168 FMI 14 J1939: SA 3 SPN 168 FMI 14 Overview This fault

More information

Page 1 of 29 Section 04-05: Suspension, Computer Controlled 1997 Town Car Workshop Manual DIAGNOSIS AND TESTING Procedure revision date: 05/16/2000 Suspension, Computer Controlled Inspection and Verification

More information

D3000. Troubleshooting Guide

D3000. Troubleshooting Guide Page 1 of 6 17486-00 Rev B s3 April 2009 Contents Description Page Safety.. 3 Introduction 3 Standard External Controls, Indicators and Normal Alarm Conditions 3 Troubleshooting Table.. 4 Unable to program

More information

Electronic Products ELECTRONIC MAINTENANCE

Electronic Products ELECTRONIC MAINTENANCE SubDrive2W, 75, 100, 150, 300, MonoDrive, and MonoDrive XT Should an application or system problem occur, built-in diagnostics will protect the system. The FAULT light or digital display on the front of

More information

Technical Data for 3100 Series Melters

Technical Data for 3100 Series Melters Part D, Section 1 This section covers the following unit configurations. Model 3100 Voltage All Pump All Manifold All Control All 1-3000 D 1-0 1-3000 D 1-1 Section D 1 1. Specifications Viscosity Range

More information

Power Distribution System User s Manual. Model: PDS-100

Power Distribution System User s Manual. Model: PDS-100 Power Distribution System User s Manual Model: PDS-0 Section Page Product Overview... 1 I) General Information... 2 II) Important Safety Information... 2 III) Installation... 3 A) Materials Provided...

More information

9.1.4 Troubleshooting of Faults in LCD Screen

9.1.4 Troubleshooting of Faults in LCD Screen User Manual 9 and Maintenance 9.1.2 Arc Detection Self-test An auto-test circuit is included in the module design of the inverter s AFDI function. If a DC arc fault is detected, the corresponding fault

More information

PAGE Both power cords must be connected & powered to operate the E-TES 120.

PAGE Both power cords must be connected & powered to operate the E-TES 120. PAGE 1 This document outlines questions to ask and components to check during E-TES 120 troubleshooting. More detailed troubleshooting procedures are available in the E-TES 120 Troubleshooting Guide. 1.

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

Series 3900/M Pump Retrofit Kit

Series 3900/M Pump Retrofit Kit Instruction Sheet P/N Series 900/M Pump Retrofit Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E Nordson Corporation OPERATOR S CARD P/N 32 96E Select Series H-400 Hot Melt Dispensing Guns Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection

More information

MOTORTRONICS Solid State AC Motor Control

MOTORTRONICS Solid State AC Motor Control Solid State AC Motor Control MWH Series Solid State Motor Winding Heater 10 to 80 Amps INSTALLATION & START-UP MANUAL REV 4 6091101MN Table of Contents Chapter 1: General Information... 1 1.1 Introduction

More information

EB Conveyor Maintenance Guide

EB Conveyor Maintenance Guide EB Conveyor Maintenance Guide EN-0037 Rev A EB Conveyor Maintenance Guide www.qdraw.com Table of Contents Overview Page 3 Exploded View Of A Standard EB Conveyor Page 4 Preventative Maintenance Page 5

More information

INSTALLATION & OWNER S MANUAL

INSTALLATION & OWNER S MANUAL 1 of 18 INSTALLATION & OWNER S MANUAL (*Not including cab & other accessories) A/C Alternator Kit: Yamaha Drive & Drive2 P/N: 1ACYDR2DRK Recommended it be installed with Curtis Cab: Sandstone (p/n 1GCYD1-A,

More information

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater. 0 EDITION AIM MANUAL SUBMERSIBLE MORS APPLICATION INSTALLATION 60 Hz, Single-Phase and Three-Phase Motors franklinwater.com All Motors System Troubleshooting Motor Does Not Start A. No power or incorrect

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit. PAGE 1 This document outlines questions to ask and components to check during E-TES SD 120 volt troubleshooting. More detailed troubleshooting procedures are available in the E-TES SD 120 volt Troubleshooting

More information

3000W HF/PFC Battery Charger

3000W HF/PFC Battery Charger 3000W HF/PFC Battery Charger Description Advanced high frequency switching design with 92% typical efficiency Fully sealed enclosure providing improved reliability in demanding environments > 0.98 Power

More information

Battery Control Center - Diesel

Battery Control Center - Diesel Service Manual CAUTION: All servicing of the Battery Control Center should be done only by a qualified Service Technician. Inadvertent shorts inside the Battery Control Center could result in severe damage

More information

TOYOTA CAMRY LE / SE / XLE DUAL SEAT HEATER KIT Section I Pre-Installation Check

TOYOTA CAMRY LE / SE / XLE DUAL SEAT HEATER KIT Section I Pre-Installation Check Section I Pre-Installation Check Kit Part Number: 250-1897 3 General Applicability Camry LE / SE / XLE 5 4 1 Recommended Sequence of Application Item # Accessory 1 Wiring 2 Elements 3 2 Kit Contents Item

More information

WARRANTY INFORMATION...

WARRANTY INFORMATION... Table of contents 1 General Information... 3 1.1 Description... 3 1.2 Features... 3 1.3 Specifications... 4 1.4 Receiving and Unpacking... 4 1.5 Dimensions... 4 2 Installation... 5 2.1 Wiring... 5 3 Operation...

More information

PFC W HF/PFC Battery Charger

PFC W HF/PFC Battery Charger PFC 5000 5000W HF/PFC Battery Charger Description Advanced high frequency switching design with 92% typical efficiency Fully sealed enclosure providing improved reliability in demanding environments >

More information

E-200 Module Service Kit

E-200 Module Service Kit Instruction Sheet E-200 Module Service Kit 1. Introduction These instructions describe how to remove and replace the E-200 module. The instructions include the following: S S S S Safety Unit Preparation

More information

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. Technical Information and Diagnostic Guide for SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. This guide will assist you in becoming more

More information

The Da-Lite Difference.

The Da-Lite Difference. The Da-Lite Difference. Instruction Book for Large Advantage Electrol DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737

More information

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified. SERVICE MANUAL GRA SERIES GAS FRYERS WITH KLEENSCREEN PLUS FILTRATION SYSTEMS 2GR45AF KLEENSCREEN FRYER BATTERY MODEL ML MODEL ML 1GR45A 136647 3GR85AF 136655 1GR65A 136648 4GR45AF 136656 1GR85A 136649

More information

ENGINE COOLING FAN Toyota Celica ELECTRIC COOLING FAN RADIATOR COOLING FAN SYSTEM TEST ENGINE COOLING Toyota Engine Cooling Fans

ENGINE COOLING FAN Toyota Celica ELECTRIC COOLING FAN RADIATOR COOLING FAN SYSTEM TEST ENGINE COOLING Toyota Engine Cooling Fans ENGINE COOLING FAN 1994 Toyota Celica 1994 ENGINE COOLING Toyota Engine Cooling Fans Celica 1.8L 4-Cyl ELECTRIC COOLING FAN NOTE: Electric cooling fan may be used for radiator or condenser. To verify electric

More information

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING. C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide WARNING Before troubleshooting any CEN products, the service technician should: read, understand, and agree to follow all information

More information

8803214-8803999 DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification

More information

DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification PIN # WIRE # SIGNAL

More information

EXTREME R MOTOR OWNER'S MANUAL

EXTREME R MOTOR OWNER'S MANUAL EXTREME R MOTOR OWNER'S MANUAL 2 HP, 3 HP & 5 HP WITH SELF-ENGAGING CHAIN HOIST FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) 594-4969 3137B(0) ECN 1313 BY JM 7/9/15 OPERATOR SERIAL# PRO-FDG MOTOR OPERATORS

More information

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing. Thunder Power Tarp Kit Operation Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing 011-52475 Rev - 2 P a g e USE THE PROCEDURES BELOW TO OPERATE THE TARP SYSTEM Powering

More information