1 Instruction Sheet P/N SP30 10:1 Piston Pump 1. Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and maintenance (hereafter referred to as use ) of the product described in this document (hereafter referred to as equipment ). Additional safety information, in the form of task-specific safety alert messages, appears as appropriate throughout this document. WARNING: Failure to follow the safety messages, recommendations, and hazard avoidance procedures provided in this document can result in personal injury, including death, or damage to equipment or property. 2. Safety Alert Symbols The following safety alert symbol and signal words are used throughout this document to alert the reader to personal safety hazards or to identify conditions that may result in damage to equipment or property. Comply with all safety information that follows the signal word. WARNING: Indicates a potentially hazardous situation that, if not avoided, can result in serious personal injury, including death. CAUTION: Hot surfaces! Avoid contact with the hot metal surfaces of guns, hoses, and certain components of the melter. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury. CAUTION: (Used without the safety alert symbol) Indicates a potentially hazardous situation that, if not avoided, can result in damage to equipment or property Nordson Corporation

2 2 SP30 10:1 Piston Pump 3. Responsibilities of the Equipment Owner Equipment owners are responsible for managing safety information, ensuring that all instructions and regulatory requirements for use of the equipment are met, and qualifying all potential users. Safety Information Research and evaluate safety information from all applicable sources, including the owner-specific safety policy, best industry practices, governing regulations, material manufacturer s product information, and this document. Make safety information available to equipment users in accordance with governing regulations. Contact the authority having jurisdiction for information. Maintain safety information, including the safety labels affixed to the equipment, in readable condition. Instructions, Requirements, and Standards Ensure that the equipment is used in accordance with the information provided in this document, governing codes and regulations, and best industry practices. If applicable, receive approval from your facility s engineering or safety department, or other similar function within your organization, before installing or operating the equipment for the first time. Provide appropriate emergency and first aid equipment. Conduct safety inspections to ensure required practices are being followed. Re-evaluate safety practices and procedures whenever changes are made to the process or equipment Nordson Corporation

3 SP30 10:1 Piston Pump 3 User Qualifications Equipment owners are responsible for ensuring that users: Receive safety training appropriate to their job function as directed by governing regulations and best industry practices. Are familiar with the equipment owner s safety and accident prevention policies and procedures. Receive, equipment- and task-specific training from another qualified individual. NOTE: Nordson can provide equipment-specific installation, operation, and maintenance training. Contact your Nordson representative for information. Possess industry- and trade-specific skills and a level of experience appropriate to their job function. Are physically capable of performing their job function and are not under the influence of any substance that degrades their mental capacity or physical capabilities. 4. Applicable Industry Safety Practices The following safety practices apply to the use of the equipment in the manner described in this document. The information provided here is not meant to include all possible safety practices, but represents the best safety practices for equipment of similar hazard potential used in similiar industries. Intended Use of the Equipment Use the equipment only for the purposes described and within the limits specified in this document. Do not modify the equipment. Do not use incompatible materials or unapproved auxiliary devices. Contact your Nordson representative if you have any questions on material compatibility or the use of non-standard auxiliary devices Nordson Corporation

4 4 SP30 10:1 Piston Pump Instructions and Safety Messages Read and follow the instructions provided in this document and other referenced documents. Familiarize yourself with the location and meaning of the safety warning labels and tags affixed to the equipment. Refer to Safety Labels in this section. If you are unsure of how to use the equipment, contact your Nordson representative for assistance. Installation Practices Install the equipment in accordance with the instructions provided in this document and in the documentation provided with auxiliary devices. Ensure that the equipment is rated for the environment in which it will be used and that the processing characteristics of the material will not create a hazardous environment. Refer to the Material Safety Data Sheet (MSDS) for the material. If the required installation configuration does not match the installation instructions, contact your Nordson representative for assistance. Position the equipment for safe operation. Observe the requirements for clearance between the equipment and other objects. Install lockable power disconnects to isolate the equipment and all independently powered auxiliary devices from their power sources. Properly ground all equipment. Contact your local building code enforcement agency for specific requirements. Ensure that fuses of the correct type and rating are installed in fused equipment. Contact the authority having jurisdiction to determine the requirement for installation permits or inspections Nordson Corporation

5 SP30 10:1 Piston Pump 5 Operating Practices Familiarize yourself with the location and operation of all safety devices and indicators. Confirm that the equipment, including all safety devices (guards, interlocks, etc.), is in good working order and that the required environmental conditions exist. Use the personal protective equipment (PPE) specified for each task. Refer to Equipment Safety Information or the material manufacturer s instructions and MSDS for PPE requirements. Do not use equipment that is malfunctioning or shows signs of a potential malfunction. Maintenance and Repair Practices Perform scheduled maintenance activities at the intervals described in this document. Relieve system hydraulic and pneumatic pressure before servicing the equipment. De-energize the equipment and all auxiliary devices before servicing the equipment. Use only new factory-authorized refurbished or replacement parts. Read and comply with the manufacturer s instructions and the MSDS supplied with equipment cleaning compounds. NOTE: MSDSs for cleaning compounds sold by Nordson are available from Nordson s Website at or by calling Nordson Technical Support. Confirm the correct operation of all safety devices before placing the equipment back into operation. Dispose of waste cleaning compounds and residual process materials according to governing regulations. Refer to the applicable MSDS or contact the authority having jurisdiction for information. Keep equipment safety warning labels clean. Replace worn or damaged labels Nordson Corporation

6 6 SP30 10:1 Piston Pump 5. Equipment Safety Information This part provides safety information applicable to the following types of Nordson equipment: hot melt and cold adhesive application equipment, including melters, hoses, and guns. auxiliary equipment, including pattern-controllers, timers, and other similiar devices. Equipment Shutdown To safely complete many of the procedures described in this document, the user must first shut down the equipment. The level of shut-down required varies by the type of equipment in use and the procedure being completed. When required, shut-down instructions appear at the start of the procedure. Each level of shut-down is described below. Relieve System Hydraulic Pressure Completely relieve system hydraulic pressure before breaking any hydraulic connection or seal. Refer to the melter-specific product manual for instructions on relieving system hydraulic pressure. De-energize the System Isolate the system (melter, hoses, guns, and auxiliary devices) from all power sources before accessing any unprotected high-voltage wiring or connection point. 1. Turn off the equipment and all auxiliary devices connected to the equipment (system). 2. To prevent the equipment from being accidentally energized, lock and tag the disconnect switch(es) or circuit breaker(s) that provide input electrical power to the equipment and auxiliary devices. NOTE: Government regulations and industry standards dictate specific requirements for the isolation of hazardous energy sources. Refer to the appropriate regulation or standard Nordson Corporation

7 SP30 10:1 Piston Pump 7 Disable the Gun All electrical or mechanical devices that provide an activation signal to the gun solenoid(s) or the melter pump must be disabled before work can be performed on or around a gun that is connected to a pressurized system. 1. Turn off or disconnect the gun triggering device (pattern controller, timer, PLC, etc.) 2. Disconnect the input signal wiring to the gun solenoid valve(s). 3. Reduce the air pressure to the gun solenoid valve(s) to zero; then relieve the residual air pressure between the regulator and the gun. General Safety Warnings and Cautions This part contains general safety warnings and cautions and first aid information applicable to the use of the equipment described in this document. WARNING: Hazardous vapors! Before processing any Polyurethane Reactive (PUR) hot melt or solvent-based material through a compatible Nordson melter, read and comply with the material s MSDS. Ensure that the material s processing temperature and flashpoints will not be exceeded and that all requirements for safe handling, ventilation, first aid, and personal protective equipment are met. Failure to comply with MSDS requirements can cause personal injury, including death. WARNING: Reactive material! Never clean any aluminum component or flush Nordson equipment with halogenated hydrocarbon fluids. Nordson melters and guns contain aluminum components that may react violently with halogenated hydrocarbons. The use of halogenated hydrocarbon compounds in Nordson equipment can cause personal injury, including death Nordson Corporation

8 SP30 10:1 Piston Pump General Safety Warnings and Cautions (contd.) WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result in the uncontrolled release of hot melt that can cause personal injury. WARNING: Molten Material! Wear eye or face protection, clothing that protects exposed skin, and heat-protective gloves when servicing equipment that contains molten hot melt. Even when solidified, hot melt can still cause burns. Failure to wear appropriate personal protective equipment can result in personal injury. WARNING: Equipment starts automatically! Remote triggering devices are used to control automatic hot melt guns. Before working on or near an operating gun, disable the gun s triggering device and remove the air supply to the gun s solenoid valve(s). Failure to disable the gun s triggering device and remove the supply of air to the solenoid valve(s) can result in personal injury. WARNING: Risk of electrocution! Even when switched off and electrically isolated at the disconnect switch or circuit breaker, the equipment may still be connected to energized auxiliary devices. De-energize and electrically isolate all auxiliary devices before servicing the equipment. Failure to properly isolate electrical power to auxiliary equipment before servicing the equipment can result in personal injury, including death. WARNING: Risk of fire or explosion! Nordson cold adhesive equipment is not rated for use in explosive environments and should not be used with solvent-based adhesives that can create an explosive atmosphere when processed. Refer to the MSDS for the adhesive to determine its processing characteristics and limitations. The use of incompatible solvent-based adhesives or the improper processing of solvent-based adhesives can result in personal injury, including death Nordson Corporation

9 SP30 10:1 Piston Pump 9 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment can result in injury, including death, to themselves and others, and damage to the equipment. CAUTION: Hot surfaces! Avoid contact with the hot metal surfaces of guns, hoses, and certain components of the melter. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury. CAUTION: Some Nordson melters are specifically designed to process Polyurethane Reactive (PUR) hot melt. Attempting to process PUR in equipment not specifically designed for this purpose can damage the equipment and cause premature reaction of the hot melt. If you are unsure of the equipment s ability to process PUR, contact your Nordson representative for assistance. CAUTION: Before using any cleaning or flushing compound on or in the equipment, read and comply with the manufacturer s instructions and the MSDS supplied with the compound. Some cleaning compounds can react unpredictably with hot melt, resulting in damage to the equipment. CAUTION: Nordson hot melt equipment is factory tested with Nordson Type R fluid that contains Polyester Adipate plasticizer. Certain hot melt materials can react with Type R fluid and form a solid gum that can clog the equipment. Before using the equipment, confirm that the hot melt is compatible with Type R fluid Nordson Corporation

10 10 SP30 10:1 Piston Pump Other Safety Precautions Do not use an open flame to heat hot melt system components. Check high pressure hoses daily for signs of excessive wear or damage. Never point a dispensing handgun at yourself or others. Suspend dispensing handguns by their proper suspension point. First Aid If molten hot melt comes in contact with your skin: 1. Do NOT attempt to remove the molten hot melt from your skin. 2. Immediately soak the affected area in clean, cold water until the hot melt has cooled. 3. Do NOT attempt to remove the solidified hot melt from your skin. 4. In case of severe burns, treat for shock. 5. Seek expert medical attention immediately. Give the MSDS for the hot melt to the medical personnel providing treatment Nordson Corporation

11 SP30 10:1 Piston Pump Introduction The hydraulics system consists of the air driven piston pump assembly and a manifold assembly. The pump assembly includes an air section, an actuator, and a single-acting hydraulic pump. The manifold assembly is indirectly heated by the tank heaters. The manifold assembly consists of an aluminum manifold, a filter assembly, a drain valve, and hose ports with 45 degree connecting elbows. See Figure A Fig. 1 Manifold Assembly 1. Air section 2. Single-acting hydraulic pump 3. Manifold assembly 4. Drain Valve 5. Filter Assembly 2001 Nordson Corporation

12 12 SP30 10:1 Piston Pump 7. Pump Repair Procedures NOTE: Flush the system before disassembly. If the pump does not work, but the heating system does, heat the applicator to operating temperature to facilitate disassembly. If the heating system does not work, use a heat gun or other flameless heating device to melt the solidified hot melt material in or on the system parts. Pump Replacement 1. Turn the circuit breaker off and lock out electrical power. Allow time for the hot melt material in the tank to cool but not to solidify. 2. Remove the pump enclosure. 3. Set the pump air regulator to 0 (zero). Turn off the air supply to the regulator. See Figure Fig. 2 Regulating Air Supply WARNING: Hot! Risk of burns. Wear heat-protective clothing, safety goggles, and heat protective gloves. Hot melt material may be released forcibly. 4. Trigger guns or open the manifold drain valve to relieve air pressure. 5. Disconnect the air inlet line to the air control valve assembly. 6. Remove the bolts and washers that secure the pump assembly to the applicator. See Figure Check that the hot melt material is not solid. Reheat if necessary. NOTE: Have a pan available to catch drips A Fig. 3 Removing the Bolts and Washers 2001 Nordson Corporation

13 SP30 10:1 Piston Pump 13 Pump Replacement (contd.). Rotate the pump slightly to break the suction; then pull straight up to disengage the crossover tube from the manifold. See Figure Hold the new pump assembly in position over the applicator. 10. Position the crossover tube in the manifold inlet port and lower the pump into position. 11. Secure the pump assembly to the applicator with the bolts and washers removed previously. Apply torque of N m (9 10 ft lb). See Figure Connect the air inlet line to the actuator assembly. 13. Replace the pump enclosure. 14. Purge the system of trapped air. Fig. 4 Rotating the Pump A Restoring the System to Normal Operation 1. Reinstall the pump cover. 2. Remove the lockout and restore power to the unit. 3. Turn the unit ON and allow it to reach operating temperature. 4. Place a container under the manifold drain valve and open the valve. See Figure 5. Filter Type Standard Reverse-flush Procedure for Opening Drain Valve Turn the drain valve counterclockwise. With the manifold filter in the RUN position, open the right-side drain valve. 1 Fig. 5 Opening the Manifold Drain Valve 1. Manifold with a standard filter 2. Manifold with a reverse-flush filter A 2001 Nordson Corporation

14 14 SP30 10:1 Piston Pump 5. Increase pump air pressure. 6. Switch the 24 VDC or 115 VAC signal to the triggering solenoid valve on and off until clean adhesive flows from the drain valve. This will purge the system of trapped air. 7. Reduce the pump air pressure to zero.. Close the drain valve. 9. Return the air pressure to the normal operating setting and resume operation.. Pump Solenoid Valve Replacement Procedures Use the following procedures to replace either the internal or triggering solenoid valve. Replacing the Internal Solenoid Valve Replacing the Triggering Solenoid Valve Replacing the Manifold Refer to the parts lists for the part numbers of any components that need to be replaced. Use the solenoid valve assembly parts list illustration as a guide for replacing other solenoid valve assembly components. Replacing the Internal Solenoid Valve Follow this procedure to replace the solenoid valve located inside the electrical enclosure Nordson Corporation

15 SP30 10:1 Piston Pump 15 Solenoid Valve Removal WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit. 1. Place the unit s POWER switch in the OFF position, disconnect and lock out electrical power to the unit at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. 2. Reduce the pump air pressure to zero. WARNING: Risk of electrical shock. Failure to observe electrical safety procedures may result in personal injury or death. Allow only qualified personnel to perform the following procedures. Observe all high voltage indicators. 3. Open the electrical enclosure. Refer to your applicator manual for instructions. 4. Unplug (1) the solenoid valve. See Figure Disconnect the air lines (3) from the elbows (2) on the solenoid valve. 6. Remove the screws that secure the solenoid valve mounting bracket (4) to the unit; then remove the valve and bracket from the unit. 7. Remove the screws (5) that secure the mounting bracket to the solenoid valve and disconnect the bracket from the valve.. Remove the elbows (2) from the solenoid valve Fig. 6 Solenoid Valve Assembly Components 1. Plug 4. Mounting bracket 2. Air lines 5. Screws 3. Elbows A 2001 Nordson Corporation

16 16 SP30 10:1 Piston Pump Solenoid Valve Installation 1. Install the elbows (2) on the new solenoid valve. See Figure Install the mounting bracket (4) on the new solenoid valve. 3. Install the mounting bracket (4) and solenoid valve on the rear cover of the unit with the screws removed earlier. 4. Connect the air lines (3) to the solenoid valve elbows. 5. Connect the solenoid valve plug. 6. Close the electrical enclosure, remove the lockout, and restore power to the unit. 7. Return the pump air pressure to the normal operating setting.. Turn the unit ON and listen for air leaks. If you hear air leaking, check and retighten the air line connections at the elbows. Replacing the Triggering Solenoid Valve Follow this procedure to replace the triggering solenoid valve that is connected to the pump. Solenoid Valve Removal WARNING: Risk of equipment damage, personal injury, or death. Disconnect and lock out electrical power to the unit. 1. Place the unit s POWER switch in the OFF position. 2. Disconnect and lock out electrical power to the unit at the branch circuit disconnect switch. 3. Disconnect and lock out electrical power supplied through any I/O wiring. 4. Reduce the pump air pressure to Remove the electrical enclosure lid and the pump cover. 6. Disconnect the air line from the triggering solenoid valve elbow (1). See Figure Nordson Corporation

17 SP30 10:1 Piston Pump 17 Solenoid Valve Removal (contd) 7. Disconnect the solenoid valve wires (5) from terminals three and four on the center frame terminal block. Do not disconnect the wires from the triggering device. See Figures 13, 14, 15, and 16 (Solenoid Valve Assembly Parts) which show the solenoid valve wires connected to the terminal block.. Disconnect the solenoid valve ground wire (4) from the ground stud on the unit s base. 9. Unscrew the solenoid valve (2) from the pipe nipple (3) Fig. 7 Triggering Solenoid Valve Components (Model 3930 shown) 1. Elbow 4. Ground wire 2. Solenoid valve 5. Solenoid valve wires 3. Pipe nipple A 2001 Nordson Corporation

18 1 SP30 10:1 Piston Pump Solenoid Valve Installation 1. Install the solenoid valve onto the pipe nipple. See Figure Connect the air line to the solenoid valve elbow. 3. Route the solenoid valve wires around the center frame and connect them to terminals 3 and 4 on the center frame terminal block. Figures 13, 14, 15 and 16 show the solenoid valve wires connected to the terminal block. 4. Connect the solenoid valve ground wire to the ground stud on the unit s base. 5. Install the pump cover and the electrical enclosure lid. 6. Return the pump air pressure to the normal operating setting. 7. Remove the lockout and restore power to the unit.. Turn the unit ON and listen for air leaks. If you hear air leaking, check and retighten the air line connections at the elbow. Replacing the Manifold Because the manifold has no moving parts, it should not need to be replaced. However, if the manifold needs to be removed for any reason, refer to your Applicator Manual Nordson Corporation

19 SP30 10:1 Piston Pump Uptime and Uptime Plus Nordson Uptime and Uptime Plus packs provide parts for fast, efficient repairs. Fee Figure. Uptime packs consist of maintenance parts for normal wear items. Uptime Plus packs provide protection for additional repairs that are needed after long, hard usage. The Uptime Plus pack is available for the complete replacement of the pump module. See the Piston Pump parts list and Solenoid Valve Assembly parts list for information on available Uptime packs. Fig. Uptime Plus A 2001 Nordson Corporation

20 20 SP30 10:1 Piston Pump 10. Parts Lists To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five column parts lists, and the accompanying illustrations, to describe and locate parts correctly. Using the Parts List Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list. The code NS (not shown) indicates that a listed part is not illustrated. A dash ( ) is used when the part number applies to all parts in the illustration. The six-digit or seven-digit number in the Part column is the Nordson Corporation part number. A series of dashes in this column ( ) means the part cannot be ordered separately. The Description column gives the part name, as well as its dimensions and other characteristics when appropriate. Indentions show the relationships between assemblies, subassemblies, and parts. Item Part Description Quantity Note Assembly Subassembly 2 A Part 1 If you order the assembly, items 1 and 2 will be included. If you order item 1, item 2 will be included. If you order item 2, you will receive item 2 only. The number in the Quantity column is the quantity required per unit, assembly, or subassembly. The code AR (As Required) is used if the part number is a bulk item ordered in quantities or if the quantity per assembly depends on the product version or model. Letters in the Note column refer to notes at the end of each parts list. Notes contain important information about usage and ordering. Special attention should be given to notes Nordson Corporation

21 SP30 10:1 Piston Pump 21 10:1 Piston Pump (D) Parts See Figure 9 12 for your specific model. Item Part Description Quantity Note Service Kit, pump D, 10:1 with solenoid valve, 3500V 1 B Service Kit, pump D, 10:1 with solenoid valve, 3700V 1 B Service kit, pump D, 10:1, with solenoid valve, 3930V Service kit, pump D, 10:1, with solenoid valve, 360V, 390V, and 3960V Service kit, check valve and ball A Seat, ball check valve Ball, 440 stainless steel, in., Service kit, crossover tube, backup ring, and O-ring A Tube, crossover Backup ring, single, 7 / 16 in. x 9 / 16 in O-ring, Viton, in. ID x 0.70 in. wide Service kit, siphon ball, seat, and cage A Cage, ball, siphon Ball, 440 stainless steel, in., Seat, siphon ball Service kit, solenoid assembly, 10:1 1 A NOTE A: Included in service kits and B: Pump and solenoid available as separate assemblies in Uptime Plus Pack Nordson Corporation

22 22 SP30 10:1 Piston Pump A Fig. 9 Model Nordson Corporation

23 SP30 10:1 Piston Pump 23 10:1 Piston Pump (D) Parts (contd.) A Fig. 10 Model Nordson Corporation

24 24 SP30 10:1 Piston Pump B Fig. 11 Model A Fig. 12 Models 360, 390, and Nordson Corporation

25 SP30 10:1 Piston Pump 25 Solenoid Valve Assembly Parts See Figure for your specific model. Item Part Description Quantity Note Pump assembly, 3500V and 3700V 1 J Pump assembly, 3930V Pump assembly, 360V, 390V, and 3960V 1 A Bracket, cover, pump 1 H Elbow, male, pipe, hyd, 1/ brass 1 H, I Elbow, pipe, hyd, 90, 1/, stl, zn 1 H, I Nipple, hex, 1 / NPT X 1 / NPT X 1.06 in. 1 G Nipple, steel, 1 / X 3.00 H Nipple, steel, 1 / X 0.75 I Service kit, solenoid valve, 10:1 1 B,C Elbow, male, 3 / in. tube x 1 / NPT, Viton Tubing, 3 / in. 1 D Frame, center 1 E Block, terminal, 4 station Elbow, male, 3 / in. tube x 1 / 4 NPT, Viton Screw, pan-head, recessed, M5 x mm Screw, cross-pan, #10 31 x in Bracket, mounting, solenoid valve Service kit, solenoid valve, 2 way, 24 VDC, 1 / 4 NPT 1 C, F Grommet, ID in Adapter, 1 / 4 NPTF Screw, pan head, recessed, M5 x 10 mm Frame, hose end 1 E NOTE A: Refer to Piston Pump Parts List. B: This is the triggering solenoid valve. C: This service kit is included in the pump service kits P/N , , and D: Specify required length when ordering replacement tubing. E: Refer to Frame Assembly Parts List in the applicator manual. F: This is the internal solenoid valve. G: 330, 360, 3930 and 3960 only H: 3500 only I: 3700 only J: Available as Uptime Pack Nordson Corporation

26 26 SP30 10:1 Piston Pump A Fig. 13 Model Nordson Corporation

27 SP30 10:1 Piston Pump 27 Solenoid Valve Assembly Parts (contd.) A Fig. 14 Model Nordson Corporation

28 2 SP30 10:1 Piston Pump A Fig. 15 Model Nordson Corporation

29 SP30 10:1 Piston Pump 29 Solenoid Valve Assembly Parts (contd.) A Fig. 16 Models 360, 390 and Nordson Corporation

30 30 SP30 10:1 Piston Pump 10:1 Piston Pump Assembly Parts See Figures 17 and 1. Item Part Description Quantity Note Pump Assembly 3500 and 3700V A Pump Assembly 3930V A Pump Assembly 360V, 390V, and 3960V A Screw, hex-head, cap M6 x 120 mm 4 B Washer, lock, M, split, M Cap, Air Cylinder, single-acting 1 G Bumper, piston stop O-ring, Viton, x 3.75 x in. 1 C Cylinder, air, high-volume Nut, hex, M6, Lock 1 B Stop, pump, piston Washer, piston, cup, high-volume Cup, piston, high-volume Washer, piston, seal, high-volume Retaining ring, external, 112, basic Washer, flat, E, spring-guide Support, spring guide Spring, compression, x 1.50 x in Adapter, air cylinder, high volume 1 D Retainer, spring Nut, lock, bearing, PN Washer, lock, E, bearing, PN Seat, ball check, valve 1 H Ball, 440 stainless steel, in Mount, pump, machined, 10:1 1 E Mount, pump, machined, 10:1 1 F Retaining Ring, Internal, 1, basic Washer, OD x ID x in. thick Seal, pump 1 Continued on next page 2001 Nordson Corporation

31 SP30 10:1 Piston Pump 31 10:1 Piston Pump Assembly Parts (contd.) Item Part Description Quantity Note Body, pump, single-acting Tube, crossover 1 B Back-up ring, single, 7 / 16 x 9 / 16 in O-ring, Viton, ID x in. width 1 C Pin, groove, type-a, ID x 1.0 in Rod, pump, single-acting O-ring, Viton, ID x in. 1 C Plug, piston, single-acting O-ring, Viton, ID x 0.6 in. 1 C Piston, pump, single-acting, hydraulic Screw, shoulder, 1 / 4 20 x in. OD 1 H Cage, ball, siphon Ball, 440, stainless steel, in Seat, siphon ball 1 NOTE A: For a complete pump, order this part number. B: Apply anti-seize compound, part C: Apply high-temperature lubricant, part D: Part of item 26 on pump assemblies and E: Assembly only. F: Assemblies and only. G: Refer to figures 9, 10, 11, or 12 for orienting this component. H: Apply retaining cylindrical adhesive, part Nordson Corporation

32 32 SP30 10:1 Piston Pump A B Fig :1 Piston Pump (1 of 2) 2001 Nordson Corporation

33 SP30 10:1 Piston Pump 33 10:1 Piston Pump Assembly Parts (contd.) 26 A B Fig. 1 10:1 Piston Pump (2 of 2) 2001 Nordson Corporation

34 34 SP30 10:1 Piston Pump 11. Air Pressure Regulator and Filter Assembly See Figure 19. Item Part Description Quantity Note Regulator/filter assembly, 90 psi, 4 hose A Regulator/filter assembly, 90 psi, 6 hose B Regulator, filter, air, 1 / 4 NPT Nipple, brass, 40, 1 / 4 in., 2.50 in. 1 A Nipple, brass, 40, 1 / 4 in., 5.00 in. 1 B Gauge, air, 1 / NPT, 90 psi Service kit, filter element Service kit, filter bowl 1 NOTE A: Used only on 4 hose units. B: Used only on 6 hose units Fig. 19 Air Pressure Regulator Assembly Original copyright date Nordson and the Nordson logo are registered trademarks of Nordson Corporation Nordson Corporation

8. Illustrated Parts Lists

8. Illustrated Parts Lists Hydraulics B 1-43 8. Illustrated Parts Lists To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations,

More information

8. Illustrated Parts Lists

8. Illustrated Parts Lists Hydraulics B 1-41 8. Illustrated Parts Lists To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations,

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3800V 3900V All Piston (F) 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Standard

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V Part B, Section 1 This section covers the following unit configurations. Model Voltage Pump Manifold Control 3100V 3400V 3500V 3700V All Piston (E) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Standard

More information

8. Illustrated Parts Lists

8. Illustrated Parts Lists Hydraulics B 1-45 8. Illustrated Parts Lists To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations,

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3860 3890 3930 3960 All Piston (D) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista

More information

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00 Part B, Section 5 This section covers the following unit configurations Model 5 Voltage. Pump Piston (E,) Manifold -Port (A) Control UniScan Nordson Corporation Issued / B 5- Issued / 999 Nordson Corporation

More information

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6 Part B, Section 5 Model 500 Voltage, Pump Piston (E) Manifold -Port (B or C) -Port (S or T) Control MultiScan (M) 000Nordson Corporation -000 Issued /00 B 5-0 -000 Issued /00 000 Nordson Corporation B

More information

Auto-Flo Air-Assist Automatic Dispensing Valve

Auto-Flo Air-Assist Automatic Dispensing Valve Auto-Flo Air-Assist Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its

More information

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Auto-Flo Panel Reinforcement Automatic Dispensing Valve Auto-Flo Panel Reinforcement Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries

More information

Installation Instructions for Series 3100V Low Level Indicator

Installation Instructions for Series 3100V Low Level Indicator Instruction Sheet P/N Installation Instructions for Series 3100V Low Level Indicator WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an out-in filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E Nordson Corporation OPERATOR S CARD P/N 32 96E Select Series H-400 Hot Melt Dispensing Guns Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

E-200 Module Service Kit

E-200 Module Service Kit Instruction Sheet E-200 Module Service Kit 1. Introduction These instructions describe how to remove and replace the E-200 module. The instructions include the following: S S S S Safety Unit Preparation

More information

Maintenance. Part A, Section 5. This section covers the following unit configurations.

Maintenance. Part A, Section 5. This section covers the following unit configurations. Part A, Section 5 This section covers the following unit configurations. Model 3100V 3400V 3830V 3860V 3890V 3930V Voltage 1, 2 Pump AC Gear (K or L) Manifold 4-Port (J)) Control Vista Standard (V) Vista

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with a Universal in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

Paint/Solvent/Dump Valve and Flow-Through Valve

Paint/Solvent/Dump Valve and Flow-Through Valve Instruction Sheet P/N 08573D Paint/Solvent/Dump Valve and Flow-Through Valve. Description See Figure. The paint/solvent/dump valve is a normally-closed valve that opens to trigger and/or dump coating material.

More information

Installing the Integral Platen Blow Off Valve

Installing the Integral Platen Blow Off Valve Instruction Sheet Installing the Integral Platen Blow Off Valve WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all

More information

Installing an H-200 Integral Right-Angle Module

Installing an H-200 Integral Right-Angle Module Instruction heet P/N 187 723A Installing an H-200 Integral Right-Angle Module WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this

More information

A CAUTION: The kit should not be fitted on Series 3800 or 3900

A CAUTION: The kit should not be fitted on Series 3800 or 3900 Series 3000 O:l Pump Installation Kit Instructions 6-52 Page O:l SINGLE ACTING PUMP INSTALLATION (P/N 3 598) KIT INTRODUCTION. The O:l Single Acting Pump Installation Kit gives you all the necessary items

More information

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion Instruction Sheet P/N 106501A03 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Series 3900/M Pump Retrofit Kit

Series 3900/M Pump Retrofit Kit Instruction Sheet P/N Series 900/M Pump Retrofit Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

Inverted High Pressure Fluid Filters

Inverted High Pressure Fluid Filters Instruction Sheet P/N 33290-03 Description See Figure. Nordson high-pressure fluid filters prevent nozzle-plugging by filtering contaminants out of coating materials. These stainless steel, wall-mounted

More information

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model

More information

E-200 O-rings Service Kit

E-200 O-rings Service Kit Instruction Sheet E-00 O-rings Service Kit. Introduction These instructions describe how to replace the o-rings in the E-00 gun module. It is necessary to remove and disassemble the module when replacing

More information

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV Generation II Pump Panel Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change

More information

Upgrading the Sure Coat Modular Gun Control System

Upgrading the Sure Coat Modular Gun Control System Instruction Sheet P/N 007365B Upgrading the Sure Coat Modular Gun Control System WARNING: Read the Safety section in the Sure Coat Modular Gun Control System manual before performing any of the following

More information

Blow Off Valve Retrofit Kit

Blow Off Valve Retrofit Kit Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with a threaded filter. Table of Contents Filter... 10-1 Introduction... 10-3 Filter Overview... 10-3 Filter Service... 10-4 Relieving

More information

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia eries H-400 Guns Customer Product Manual Part NORDON CORPORATION D Duluth, Georgia www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information, comments

More information

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01 Section 9 NOTE: This section applies to applicators with CC200 modules. 9-0 Table of Contents i Table of Contents Section 9 1. Introduction............................................... 9-1 2. Specifications.............................................

More information

Preventive Maintenance for Pail Melters

Preventive Maintenance for Pail Melters Instruction Sheet P/N Preventive Maintenance for Pail Melters 1. Introduction These procedures are recommended in addition to the standard preventive maintenance. Use them to keep yourvista controlled

More information

A7A Single and Dual Automatic Airless Spray Guns

A7A Single and Dual Automatic Airless Spray Guns A7A Single and Dual Automatic Airless Spray Guns Customer Product Manual Issued 8/06 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available

More information

Standard and Conical AN Series Air Spray Nozzles

Standard and Conical AN Series Air Spray Nozzles Instruction Sheet P/N 107967E Standard and Conical AN Series Air Spray Nozzles Introduction The Nordson air spray nozzles described in this instruction sheet are categorized by their type of spray pattern:

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules. 9-1 Section 9 NOTE: This section applies to applicators with CF200PAD right-angle modules. Table of Contents.................................................... 9-1 Introduction................................................

More information

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet Instruction Sheet Replacing a Gun RTD WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun Instruction Sheet P/N 237494_02 Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun WARNING! Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A Nordson Corporation OPERATOR S CARD P/N 052644A VL400 Melters Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07 RediCoat by Nordson Hopper and VBF Dolly Systems Customer Product Manual Part 1082648A Issued 10/07 This document is subject to change without notice. Nordson Corporation Amherst, Ohio USA 2 Table of Contents

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules. 9- Section 9 NOTE: This section applies to applicators with MB200 modules. Table of Contents.................................................... 9- Introduction................................................

More information

World Gun Series. Customer Product Manual Part C. Issued 11/03. NORDSON CORPORATION DULUTH, GEORGIA USA

World Gun Series. Customer Product Manual Part C. Issued 11/03. NORDSON CORPORATION DULUTH, GEORGIA USA World Gun Series Customer Product Manual Issued 11/03 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,

More information

Econo-Coat Manual Powder Spray Gun

Econo-Coat Manual Powder Spray Gun Econo-Coat Manual Powder Spray Gun Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local

More information

Spray Pressure Control Manifold

Spray Pressure Control Manifold Instruction Sheet P/N 0870G0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction The

More information

Section 8. Parts A Issued 7/00. Manual V -MA -01 (formerly 7-505/6V -MA -01) E 2000 Nordson Corporation All rights reserved

Section 8. Parts A Issued 7/00. Manual V -MA -01 (formerly 7-505/6V -MA -01) E 2000 Nordson Corporation All rights reserved Section 8 E 000 Nordson Corporation 00 497A Manual 47-506V -MA -0 (formerly 7-505/6V -MA -0) 8-0 Manual 47-506V -MA -0 (formerly 7-505/6V -MA -0) 00 497A E 000 Nordson Corporation 8- Section 8. Introduction

More information

RA-20 Paint/Solvent/Dump Valve

RA-20 Paint/Solvent/Dump Valve Instruction Sheet P/N 74B0 RA-0 Paint/Solvent/Dump Valve Description The paint/solvent valve is a normally closed valve used to trigger coating material. The valve may be used alone to actuate paint or

More information

Encore HD Powder Spray System with Prodigy Pump Cabinet

Encore HD Powder Spray System with Prodigy Pump Cabinet Encore HD Powder Spray System with Prodigy Pump Cabinet Customer Product Manual Part 604979-06 Issued 05/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at

More information

EcoLiner Compound Gun

EcoLiner Compound Gun EcoLiner Compound Gun Customer Product Manual Issued 3/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Spray Pressure Control Manifold

Spray Pressure Control Manifold Instruction Sheet P/N 0870-0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction The

More information

EP-2 Si Three-Piston Pump

EP-2 Si Three-Piston Pump EP- Si Three-Piston Pump Customer Product Manual Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your local Nordson representative.

More information

Section 8. Parts A8EN -09 -[AD -31SW/WP] AD31SW--MA--02 (formerly ) Issued 12/95. E 1995 Nordson Corporation All rights reserved

Section 8. Parts A8EN -09 -[AD -31SW/WP] AD31SW--MA--02 (formerly ) Issued 12/95. E 1995 Nordson Corporation All rights reserved Section 8 8-0 8-1 Section 8 1. Introduction To order parts, call the Nordson Customer Service Center at 800-241-8777 or your local Nordson representative. Use this five-column parts list, and the accompanying

More information

Pattern Air Control Kit (PACK)

Pattern Air Control Kit (PACK) Instruction Sheet P/N 044445B0 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or

More information

Pro-Swirl Manifold Air Heater

Pro-Swirl Manifold Air Heater Instruction Sheet P/N 16107 01 Description The Pro-Swirl manifold heats air coming from the Pro-Swirl coalescent filter. The heater air then flows through the internal passages of the Pro-Swirl to maintain

More information

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................

More information

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0

More information

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D Nordson Corporation OPERATOR S CARD P/N 321 198D Select Series H-440 Hot Melt Dispensing Guns Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B Sure Coat Modular Gun Control System Part D: Gun Purge Module Customer Product Manual Issued 4/0 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 4-919

More information

One-Gun Add-On Kit For Smart-Coat Controllers

One-Gun Add-On Kit For Smart-Coat Controllers Instruction Sheet P/N One-Gun Add-On Kit For Smart-Coat Controllers 1. Introduction This document contains procedures for installing a one-gun add-on kit to your Smart-Coat Controller. For additional information,

More information

EP2 Pump System. Customer Product Manual Part A02

EP2 Pump System. Customer Product Manual Part A02 EP2 Pump System Customer Product Manual Issued 5/08 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

D Instructions/Parts. Siphon Feed Detail Spray Gun D

D Instructions/Parts. Siphon Feed Detail Spray Gun D Instructions/Parts D-5-55 Siphon Feed Detail Spray Gun FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309991D Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

Rhino SD3/XD3 Air Motor

Rhino SD3/XD3 Air Motor Rhino SD3/XD3 Air Motor Customer Product Manual Issued 6/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson

More information

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA Installation and Maintenance Instructions Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Prodigy HDLV Pump. Customer Product Manual Part A02

Prodigy HDLV Pump. Customer Product Manual Part A02 Prodigy HDLV Pump Customer Product Manual Issued 1/07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Solenoid Valve Installation Kit

Solenoid Valve Installation Kit Instruction Sheet P/N 7 5A Solenoid Valve Installation Kit WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related

More information

5000 Gerotor Pump Service Instructions

5000 Gerotor Pump Service Instructions Instruction Sheet P/N 237569B WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction This

More information

Prodigy HDLV Pump Manifold and Circuit Board

Prodigy HDLV Pump Manifold and Circuit Board Prodigy HDLV Pump Manifold and Circuit Board Customer Product Manual Issued 05/08 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available

More information

TCU Flushing Manifold and RTD Installation

TCU Flushing Manifold and RTD Installation Instruction Sheet P/N 1614041-01 This instruction is for installing temperature control unit (TCU) flush manifold and RTD assembly onto the heat exchanger for both new systems and existing systems. Follow

More information

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit Instruction Sheet 108 792A Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit 1. Description Use this rebuild kit to service the following modules: S Normally Open H200 (N.O. H200) Module -- P/N

More information

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B Sure Coat Modular Gun Control System Part B: Pneumatic Modules Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800)

More information

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup. Instructions/Parts MGFHVLP Mini Gravity Feed System FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309989E For gravity feed spraying of automotive colors and clears. Ideal for touch-up and detail work. Important

More information

EP-2 Three-Piston Pump

EP-2 Three-Piston Pump EP- Three-Piston Pump Customer Product Manual Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your local Nordson representative.

More information

Installing the Low Level Indicator (P/N or P/N )

Installing the Low Level Indicator (P/N or P/N ) Instruction Sheet Installing the Low Level Indicator (P/N 276 176 or P/N 276 4) 1. Introduction There are two Low Level indicator kits, one for flat bottomed tanks and one for the new finned tanks. P/N

More information

Circulation Kits for CP Pumps

Circulation Kits for CP Pumps Instruction Sheet P/N 08000C Description This instruction sheet covers two circulation kits for CP Pumps: Stainless steel circulation kit, with Viton O-rings Stainless steel circulation kit, with EPR O-rings

More information

Universal Automatic Non-Conductive Fluid Regulator

Universal Automatic Non-Conductive Fluid Regulator Universal Automatic Non-Conductive Fluid Regulator Customer Product Manual Part 1017527 04 Issued 3/18 NORDSON CORPORATION AMHERST, OHIO USA Table of Contents tents Safety... 1 Qualified Personnel... 1

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules. 9-1 Section 9 NOTE: This section applies to applicators with bead or slot modules. Table of Contents... 9-1 Introduction... 9-3 Overview... 9-7 Service... 9-9 Adjusting a ClassicBlue Zero-Cavity... 9-9

More information

55-Gallon Powder Drum Truck

55-Gallon Powder Drum Truck Instruction Sheet P/N 0 0 -Gallon Powder Drum Truck for Bulk-Feed Powder Transfer Systems Description See Figure. The -gallon powder drum truck automatically adds bulk powder to a powder coating system

More information

Operating Manual High Viscosity Dispense Valve Item #

Operating Manual High Viscosity Dispense Valve Item # Operating Manual High Viscosity Dispense Valve Item # 984594 CLOSE OPEN Item # 984594 Label # 8901197 Warnings INJECTION HAZARD Spray from the valve, hose leaks, or ruptured components can inject fluid

More information

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1 5-1 Section 5 WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. NOTE: is an important

More information

Page 1 of 12. Part# /30/2016

Page 1 of 12. Part# /30/2016 Part# 1007480-02 9/30/2016 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference. INSTRUCTIONS

More information

Sure-Max Powder Transfer System

Sure-Max Powder Transfer System Sure-Max Powder Transfer System Customer Product Manual Issued 7/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern

More information

Sure Coat 90 Degree Spray Extension

Sure Coat 90 Degree Spray Extension Instruction Sheet P/N 076A Sure Coat 90 Degree Spray Extension Description The 90 Degree Spray Extension is used on Sure Coat Automatic Powder Spray Guns. It allows powder to be sprayed at right angles

More information

Hard Seat Fluid Pressure Regulator

Hard Seat Fluid Pressure Regulator Instruction Sheet P/N 04742-02 Description The Nordson hard seat fluid pressure regulator is designed for use with abrasive coatings. The regulator body is constructed of stainless steel with a nickel-plated

More information

Circulating and Non-Circulating Color Change Manifolds

Circulating and Non-Circulating Color Change Manifolds Circulating and Non-Circulating Color Change Manifolds Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about

More information

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover Description NOTE: Throughout this document, the Rhino SD2/XD2 Type-H Control Modules are referred to as the Control Module. See Figure 1. The Control Module (1) provides the pneumatic operating functions

More information

0-800 psi Carbide Seat Fluid Pressure Regulator

0-800 psi Carbide Seat Fluid Pressure Regulator Instruction Sheet P/N 0350C 0-800 psi Carbide Seat Fluid Pressure Regulator Description The Nordson 0-800 psi carbide seat fluid pressure regulator is designed for use with general liquid coatings. The

More information

Electric Vibratory Box Feeder Retrofit Kit

Electric Vibratory Box Feeder Retrofit Kit Instruction Sheet P/N 008E WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description This

More information

NOZZLETECH INC. INSTRUCTION MANUAL CEV00 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

NOZZLETECH INC. INSTRUCTION MANUAL CEV00 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA NOZZLETECH INC. 3208C EAST COLONIAL DRIVE ORLANDO, FL 32803 USA INSTRUCTION MANUAL CEV00 01/31/2013 NOZZLETECH CEV00 SERIES COMPACT ELECTRIC VALVES FOR EXTRUSION RELATED PATTERNS WARNING: The fluid supply

More information

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N Instruction heet eries AD-31 Handgun wivel Connector Replacement Kit P/N 238 808 and P/N 238 809 1. Description This instruction sheet contains procedures for replacing the swivel connector on eries AD-31

More information

E400 Electric Applicator

E400 Electric Applicator E400 Electric Applicator Customer Product Manual Issued 7/05 NORDSON CORPORATION DAWSONVILLE, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with M-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

E-900 Electric Guns. Customer Product Manual Part A. Issued 6/03. NORDSON CORPORATION DULUTH, GEORGIA USA

E-900 Electric Guns. Customer Product Manual Part A. Issued 6/03. NORDSON CORPORATION DULUTH, GEORGIA USA E-900 Electric Guns Customer Product Manual Issued 6/0 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,

More information

Rhino SD3/XD3 5-Gallon Follower Modules

Rhino SD3/XD3 5-Gallon Follower Modules Rhino SD3/XD3 5-Gallon Follower Modules Customer Product Manual Part 6033 03 Issued 6/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or

More information

Tribomatic II Extended Automatic Powder Spray Gun

Tribomatic II Extended Automatic Powder Spray Gun Tribomatic II Extended Automatic Powder Spray Gun Customer Product Manual Issued 7/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact

More information

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA NOZZLETECH INC. 3208C EAST COLONIAL DRIVE ORLANDO, FL 32803 USA INSTRUCTION MANUAL CEV10 01/31/2013 NOZZLETECH CEV10 SERIES COMPACT ELECTRIC VALVES FOR SPRAYING ROUND PATTERNS WARNING: The fluid supply

More information

Series 3000V Low Level Indicator

Series 3000V Low Level Indicator Instruction Sheet P/N 237 473A Series 3000V Low Level Indicator 1. Introduction The low level indicator sends a signal to an external device when the adhesive level in the applicator s tank is low. The

More information

Vantage Individual Powder Spray Gun Controller

Vantage Individual Powder Spray Gun Controller Vantage Individual Powder Spray Gun Controller Customer Product Manual Issued 04/15 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject

More information

SERVICE INSTRUCTIONS. Material Pump

SERVICE INSTRUCTIONS. Material Pump TM TM SERVICE INSTRUCTIONS Material Pump 9618 DESCRIPTION Model 9618 is designed for pumping petroleum products from the original container to a desired location. Due to its non-corrosive (aluminum and

More information

Page 1 of 19. Part# /10/2006

Page 1 of 19. Part# /10/2006 Part# 1002733-01 10/10/2006 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information