TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

Size: px
Start display at page:

Download "TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22"

Transcription

1 V3 TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

2 PREFACE This guide contains instructions for troubleshooting the Steffes Corporation room heating units: Models HPB 11, HPB 15, and HPB 22. In compiling this guide, Steffes Corporation has used its best judgment based upon information available but disclaims any responsibility or liability for any errors or miscalculations, contained herein, or any revisions, hereof, or which result, whole or in part, from the use of this guide, or any revision hereof. If there are any questions, contact Steffes Corporation technical support at STEFFES ( ) TABLE OF CONTENTS FLOW CHARTS Unit Will Not Charge (Unit Has No Core Charge) or Control Board Lights Are Off... 1 Unit Undercharges... 3 Unit Overcharges On Warm Days... 4 Cool Discharge Air... 5 Blower Does Not Run... 6 MISCELLANEOUS Discharge Air Check-Out Procedure Exploded View Diagram of Heat Pump Booster... 9 Heat Pump Booster Parts List

3 No Lights Heat Pump Booster Function: Core Charging Problem: Unit will not charge (Unit has no core charge) or Control Board lights are off. Before starting any of the procedures below, check voltage on load side of all HPB circuit breakers and check low voltage fuses on charge control circuit board. Place unit in off-peak mode. No Lights Check "Outdoor Temperature Sensor" lights on charge control circuit board. Check utility switch and HPB off-peak light on charge control circuit board for Check utility proper switch operation. and HPB off-peak light on charge control Lights circuit Operable board (51) for proper operation. One or more Check "Outdoor Temperature lights on Check "ETS CHARGING" Sensor" lights on charge Off indicator light on charge Jumper thermostat brown lead to control thermostat orange lead. (NOTE: Charge control light on Make sure thermostat shaft is in One or more full clockwise position.) lights on Charge light off Jumper thermostat (53) brown Replace charge control thermostat. lead to thermostat orange lead. Charge light on (NOTE: Replace Make charge sure thermostat control circuit board. shaft is in full clockwise position.) Off With charge control circuit board switches in "AUTO" and "WINTER" position: Replace outdoor air 1. Remove outdoor temperature sensor wire sensor. "G". Outdoor Held Shut temperature light #1 should be on. 2. Remove outdoor sensor wire "B". Outdoor temperature light indicator #2 should be Replace on. melt links and complete discharge air check-out procedure. Replace outdoor air temperature sensor (61). Check "ETS CHARGING" On indicator light on charge control circuit Lights board. Operable Lights Inoperable No Check for 24 VAC on orange On Present wire going to the top of the Check for defective staging sequencer Check (50). unit wiring charge sequencers or and/or replace defective heating charge No control elements. Present circuit board. Repair wiring. Opens Check slam Check gate in-line Freely fuse in assembly behind Open transformer the secondary Check units inlet/outlet Opens slam gate wiring. interlock ducting ports. Freelyswitch. Flow chart continued on next page. Lights Inoperable Check for 24 VAC between "C" terminal on SFIII board and on orange wire going to the top of the staging sequencer. Check for defective Check unit wiring charge Check sequencers for 24 VAC between and/or each replace of the two bottom low voltage fuses (58) or defective charge control and the "C" position (thermostat heating elements connection), (18). on charge circuit control board (51). Check outdoor temperature not circuit board's terminal block. Charge light off Replace thermostat (53). and refer to the Theory of present on one Above 45º Operation. or both Check for 24 Both VAC fuses Outdoor between each of the two bottom energized Temperature low voltage fuses and the "C" position (thermostat Below 45º Check line voltage supply connection), Replace on charge control Outdoor Set the charge level selector switch on to control transformer and Check outdoor temperature and not circuit board's terminal circuit board. Temperature the charge control circuit board to the unit wiring. block. "HIGH" position and retest. refer to the Theory of Operation present on one Above 45º in Appendix of the Owner's or both Both fuses Outdoor Manual. energized With charge control circuit board switches in Temperature Repair wiring. "AUTO" and "WINTER" position: Check line voltage supply to Set the charge level selector switch on 1. Remove outdoor Below 45º sensor wire "G". Outdoor control Check transformer in-line fuse in(55) and the charge control circuit board (51) Open temperature light Outdoor #1 should be on. Replace transformer unit secondary wiring. Temperature to the "HIGH" position and charge retest. control wiring if equipped. 2. Remove outdoor sensor wire "B". Outdoor circuit board. temperature light indicator #2 should be on. Good Look for a short circuit in low voltage wiring and replace transformer if necessary. Open Good Look for shorts in low Adjust or replace. voltage Check wiring secondary and replace. voltage (approximately 24 VAC) at the transformer. No Closed Proper voltage present Page 1 Page 1 Replace Transformer. Replace Charge Control Circuit Board.

4 Heat Pump Booster Function: Core Charging Problem: Unit undercharges Before starting any of the procedures below, check voltage on load side of all HPB circuit breakers. Check for 24 VAC between each of the 3-amp low voltage fuses and the "C" position (thermostat connection) on the charge control circuit board's terminal block. Unit undercharges on cold days Check charge control thermostat knob for proper position. Unit undercharges on warm days Check daily kwh usage. (See Unit Check Specifications daily kwh in Appendix usage. of (See the Unit Owner's Specifications.) Manual.) Proper Proper Maximum Maximum Usage Usage Check unit sizing. Less than Max usage Set the charge level selector switch on the charge control board (51) to the to "HIGH" the "HIGH" position. position. Check Check for for proper amperage draw on heating elements: (18): (Thiswill very slightly) HPB11B = 46 AMPS (240V systems) HPB15B = 61 AMPS (240V systems) HPB22B = 92 AMPS (240V systems) Less Less than than proper proper amperage amperage No Place the charge control circuit board switches in "WINTER" and "AUTO". Disconnect outdoor air sensor "W" wire. All Three Outdoor Temperature Lights On Check outdoor air temperature sensor in cold cold place (less (less than than15 degrees 15 F). F). All All mercury bulbs should open. All bulbs open thermostat. (53). Not All Outdoor Temperature Lights On With the charge level selector switch still in the "HIGH" position, check for zero voltage on charge control resistor from (49) both from the both center the center to bottom to bottom and the and center the center to top. top. All bulbs closed Replace outdoor air temperature sensor sensor. (61). circuit board. Check Check the outdoor the outdoor temperature lights lights on charge on charge control control circuit circuit board (51). board. All All three must be be on. on. Replace charge control circuit board (51). Open Replace sequencer(s). (58). Check for 24VAC on base terminals of all charging sequencers. (58). Check for contact closure on all charging sequencers. (58). Check heating elements elements and (18). replace as necessary. No Check unit wiring and/or replace charge control circuit board board. (51). Page 3 Page 2

5 Heat Pump Booster Function: Core Charging Problem: Unit overcharges on warm days Before starting any of the procedure below, check voltage on load side of all HPB circuit breaker and check low voltage fuses on charge control circuit board. Lights work properly Lights work properly Check operation of the three Check "Outdoor operation Temperature of the three All lights "ON" regardless of "Outdoor Sensor" lights Temperature on charge All lights outdoor "ON" temperature regardless of Sensor" control lights circuit on charge board. outdoor temperature control With wires disconnected, check With wires disconnected, check ohm values of the charge control ohm values of the charge control resistor. Must be 175 ohm center resistor (49). Must be 175 ohm to top and center to bottom. center to top and center to bottom. Check Check VAC unit on wiring resistor and (66) from middle to top and charge middle control to bottom. circuit Reults vary depending on board number fuses. of charging lights on: 1 light on = 24 VAC middle to top and bottom 2 lights on = 0 VAC middle to top; Repair 24 VAC middle to bottom 3 Replace lights on charge = 0 VAC control middle to top and bottom Incorrect Replace charge control thermostat. Check unit wiring and charge control circuit board fuses. Replace resistor (49). present Replace resistor. Fuse bad Check outdoor sensor Check wiring outdoor and Fuse bad replace sensor the wiring fuse. for short to ground and replace the fuse. If fuse continues to open, replace charge control circuit board. Check the charge level selector Check switch. the Unit charge should level not selector be in switch. "HIGH" Unit mode should on warm not be days. in "HIGH" mode on warm days. Check top (1 Check AMP) topfuse. (1 AMP) fuse. Fuse Fuse Check for 32 VDC between the "C" position (thermostat Check for connection) 32 VDC between on the charge the "C" control positioncircuit (thermostat board's terminal connection) block and on the charge top low control voltage circuit fuse on board's terminal the charge block and control the top circuit low board. voltage fuse on the charge control Check fuse. present Repair 1. With outdoor air temperature sensor wiring disconnected and the selector switches on the charge control circuit board set to "WINTER" and "AUTO" positions, jumper 1. With outdoor air temperature outdoor sensor wiring air sensor disconnected terminals "W" and the and selector "R". The switches on the charge control circuit bottom board Outdoor set to Temperature "WINTER" Sensor and "AUTO" light on positions, jumper outdoor air sensor charge terminals control "W" circuit and board "R". The should bottom be off. Outdoor Temperature Sensor light on charge control circuit board should be off. 2. Jumper "W", "R", and "B" terminals. The middle and bottom Outdoor Temperature 2. Jumper "W", "R", and "B" terminals. Sensor lights The middle on charge and control bottom circuit Outdoor board Temperature Sensor lights on charge should control go off. circuit board should go off. No voltage present No voltage present Replace charge control circuit board (51). Not Not Set to auto Set position. to auto position. Check control transformer(s) Check control and the transformer(s) two lower 3AMP (55) and fuses. the two lower 3AMP fuses. Replace fuse Replace and/or fuse transformer. and/or transformer (55). Replace charge Replace outdoor Replace air outdoor control circuit temperature sensor(61). air temperature board. sensor. Page 4 Page 3

6 Heat Pump Booster Function: Air Delivery Problem: Cool discharge air Before starting any of the procedure below, check voltage on load side of all HPB circuit breakers. Check for 24 VAC between each of the low voltage fuses the "C" position on the charge control circuit board's terminal block.. Cold Stage One Only Blower delivers cool discharge air. Cold All Stages Cold Stage One Blower delivers Uncertain cool Cold All Stages discharge air. Now Warm Iniate emergency Still Cold Does the charging system No/Uncertain heat call. work correctly? Refer to Does the charging the Theory system of Operation. work Initiate a Stage I heat call. correctly? Refer to the Theory of Not Make Initiate sure the a Stage duct sensor I heat call. is positioned Repair Operation in the Appendix of the Make properly sure the and duct check sensor field (52) wiring. is Not Owner's Manual. No Repair Refer to the appropriate core positioned properly and check field wiring. Yes Yes charging sections: Unit Undercharges Unit Overcharges Refer to the on appropriate Warm Days Unit Will core Not charging Charge sections (Unit has of no Damper doesn't Disconnect Disconnect the the red yellow wire from wire charge) this or troubleshooting Control Board guide. Lights Damper from the damper motor (22). With duct sensor (52) disconnected open the damper motor. Initiate a are Off doesn't heat Initiate call, a check heat call, voltage check at With interface duct board sensor (21), disconnected jumper theat open between voltage the between yellow the wire yellow and interface red and board, black terminal jumper the block 0 VAC red and wire the and red the wire. red wire. 0 VAC positions. black terminal Watch block for damper positions. to open. Watch for damper to open. 24 VAC 24 VAC Damper opens Are the sensors on the duct Damper opens Check voltage between 24 VAC Check voltage between sensor (52) and the air Replace duct 24 VAC the yellow the yellow wire and wire and discharge COLD ALL controller STAGES: (45) open. Are both of the sensor (52). the blue the wire. blue wire. Replace duct sensors on the air discharge controller open? No sensor. 0 VAC 0 VAC COLD STAGE Yes ONE ONLY: Are both of the Replace the interface sensors on the duct sensor open? Replace the interface board board. (21). Replace Replace the the damper Check unit Replace damper motor. motor (22). wiring. appropriate Yes No Correct sensors. Incorrect Correct Replace the interface board. Check unit Fix wiring. unit wiring. Incorrect Fix unit wiring. Replace the Replace interface air board discharge (21). controller or duct sensor. Page 5 Page 4

7 Heat Pump Booster Function: Air Delivery Problem: Blower does not run Before starting any of the procedure below, check voltage on load side of all HPB circuit breakers. Check for 24 VAC between each of the low voltage fuses and the "C" position on the charge controls circuit board's terminal block. Put heater into peak mode. Initiate a peak mode. Initiate a peak mode. present present Check for 24 VAC across "R" and "C" terminals on booster interface board (21). Check for 24 VAC across "R" and "C" terminals on booster interface board. No voltage No voltage Jumper terminal "R" to "W" on the interface board (21). Jumper terminal "R" to "W" on Motor the interface does not board. run Motor runs Motor runs Troubleshoot and repair field wiring. Troubleshoot and repair field wiring. Check for operation of fan relay (54). Check for operation of fan relay. Relay will not operate Check voltage at relay coil. Check voltage at relay coil. No voltage Replace interface board (21). Relay will not operate present No voltage Replace interface board. Motor does not run present Relay closes Relay closes Check supply voltage to core blower motor (38). Replace fan relay (54). Check field wiring and wall thermostat. Check supply voltage to core blower Improper motor. Improper Check unit wiring and fan limits (44 & 27). Check unit wiring and fan limits. Replace fan relay. Check field wiring and wall thermostat. Open Proper Proper Closed Replace core blower motor (38). Replace fan limit switch(es). Replace core blower motor. Check system wiring. Page 6 Page 5

8 CHECK OUT PROCEDURE: DISCHARGE AIR Check-Out Procedure Models: HPB11B, HPB15B and HPB22B The failure of the melt link is often the result of another problem that exists within the booster. Typically, the failure is a direct result of the inability of the booster to regulate its output temperature. If the primary problem is not rectified, melt link failure could occur again. Thus, after the failed melt link has been replaced, the booster MUST be tested to ensure that failure will not reoccur. 1. Check for proper connection of the remote mounted duct sensor, IF USED. CAUTION: Shorting of the duct sensor to the ductwork WILL cause a malfunction in the booster and result in the melt link failing. An inspection of the duct sensor mounting and clearance must be performed. 2. Remove the electrical panel cover on the front of the booster. 3. Disconnect blowers to test damper operation by removing the purple wire from the blower relay. Energize the booster s control circuit to observe the damper motor. 4. With no heat call to the booster, the damper motor should go to a fully closed (CW) position. (See Figure 1) Figure 1 5. Now, initiate a Stage 2 heat call from the booster s room thermostat. The damper motor should go to a fully open (CCW) position. (See Figure 2) 6. If the damper does not move to an opened and closed position as shown in Figures 1 and 2, check the damper system for mechanical binding and/or for CCW damper motor malfunction. 7. De-energize the control circuit and remove the RED damper motor wire from the CCW terminal. 8. Energize the control circuit again and initiate another heat call from the booster s CLOSED room thermostat. 9. Check voltage from the COM terminal and the now disconnected RED wire Figure 2 on the damper motor. 24 VAC should be present. Also, check the voltage between the COM and CW terminal. No voltage should be present. 10. Remove the air discharge sensor. Inspect the temperature sensing bulbs for separations or breaks in the mercury columns at the center of the bulbs. It may CCW be necessary to warm the bulbs to fully view the mercury columns. In many cases, if a separation exists, it can be removed by the heating of the sensor causing the mercury to move to the top of the bulb. CAUTION: Overheating the bulb can cause it to burst. SAFETY GLASSES MUST BE WORN WHEN HEATING THE BULBS. NOTE: Early booster models incorporated an air discharge sensor that signaled the booster s control system directly. Newer models use triac controls. If the booster that is being serviced does not have the triac switches on the air discharge sensor, it is recommended that the sensor be replaced. 11. De-energize the control circuit. Jumper between the upper and lower copper bulb mounting brackets of the 145 degree mercury bulb (inner bulb) on the air discharge sensor which is located in the base of the booster. 12. Energize the control circuit and check the status of the #4 LED Red light on the booster s interface board. This light must be energized (indicates the damper is satisfied). 13. Retest the voltage at the damper motor. (Refer to steps 7, 8 and 9.) If the booster does not respond correctly to the voltage check, replace the air discharge sensor. should be zero between the COM terminal and RED damper motor wire. It should also be zero between the COM terminal and the CW terminal. 14. De-energize the control circuit again. With the 145 degree sensing bulb jumper still in place on the air discharge sensor, jumper between the upper and lower copper bulb mounting brackets of the 160 degree sensing bulb (outer bulb). Page 6 OPEN CW CW

9 Discharge Air Check Out Procedure Continued 15. Energize the control circuit and check the #4 yellow LED light on the interface board. It should remain on (indicates the damper is satisfied), and there should be 24 VAC between the CW terminal and the COM terminal on the damper motor. 16. If any of the voltage tests performed in this check-out procedure do not yield the correct results, check connections from the booster s interface board to the air discharge sensor. 17. If all systems check-out, de-energize all circuits and reconnect all wires, remove all jumpers, and reassemble the booster by reversing the disassembly procedure. 18. Restore power to the booster. Consult the factory with questions or if assistance is required with replacing the melt link or checking any the systems described in this procedure. THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN Page 7

10 EXPLODED VIEW DIAGRAM Page 8

11 HPB PARTS LIST NOTE: When ordering replacement parts, please include unit model number and serial number. DWG. REF. DESCRIPTION HPB11 ITEM HPB15 ITEM HPB22 ITEM 1. Stainless Steel Panel, Back Stainless Steel Panel, Front Aluminized Steel Panel, Top Aluminized Steel Panel, Right Aluminized Steel Panel, Left " Blanket Insulation, Back & Sides (Outer) " Blanket Insulation, Back & Sides (Inner) " Blanket Insulation, Top & Front (Inner) " Blanket Insulation, Top & Front (Middle) " Blanket Insulation, Top & Front (Outer) Galvanized Steel Panel, Back Galvanized Steel Panel, Right Galvanized Steel Panel, Left Galvanized Steel Panel, Top Galvanized Steel Panel, Front Element Wiring Harness Core Temperature Sensor Main Wiring Harness Element Jumpers Heating Element (277 V, 1830W) Heating Element (208V, 1830W) Heating Element (240V, 1830W) R R R R R R R R R 19. Heat Storage Brick Control Board Mounting Plate Relay Interface Board (SFIII) R R R 22. Damper Motor R R R 23. Leveling Legs Fan Wiring Harness Base Assembly Core Charging High Limit Switch Assembly R R R o F Low Core Temperature Switch R R R 28. Limit Bar Channeling Plate Limit Bar Louvre Panel Painted Panel, Back Painted Panel, Right Painted Panel, Left Painted Panel, Front Painted Panel, Top Electrical Panel Cover Air Delivery Damper Assembly Core Damper Linkage Assembly Core Blower Motor (1/3 HP, 1625 RPM) Page 9

12 DWG. REF. DESCRIPTION HPB11 ITEM HPB15 ITEM HPB22 ITEM 39. Core Blower Wheel R R R 40. Slam Gate Interlock Switch Slam Gate Melt Link Slam Gate Melt Link Linkage Slam Gate Actuator Complete Air Discharge High Limit R R R 45. Air Discharge Controller R R R 46. Inlet/Outlet Plenum Assembly Motor Run Capacitor Circuit Breaker Standoff Charge Control Resistor Hardboard Base Insulation Charge Control Circuit Board (SFIII) Low Temperature Duct Sensor R R R 53. Charge Control Thermostat Assembly R R R 54. Fan Relay VA Control Transformer Electrical Panel Stage 2 Time Delay Sequencer Charging Sequencers Amp Circuit Breaker GE Brand* 15 Amp Circuit Breaker Siemens Brand* Amp Circuit Breaker (208/240V) Siemens Brand* 60 Amp Circuit Breaker (208/240V) GE Brand* 60 Amp Circuit Breaker (277V) GE Brand* R R R R R R R R R R R R Outdoor Air Temperature Sensor Assembly o Core Temperature Control N/A N/A * When replacing breakers in a Steffes heating system, it is important to replace with like brand heaters. Page 10

,IWKHUHDUHDQ\TXHVWLRQVFRQWDFW6WHIIHV&RUSRUDWLRQ 7HFKQLFDO6XSSRUWDW67())(6

,IWKHUHDUHDQ\TXHVWLRQVFRQWDFW6WHIIHV&RUSRUDWLRQ 7HFKQLFDO6XSSRUWDW67())(6 9 7528%/(6+227,1* *8,'( )255220+($7,1*81,76 02'(/6 (;7(;7(;7 (;7 (;7 35()$&( 7KLVJXLGHFRQWDLQVLQVWUXFWLRQVIRUWURXEOHVKRRWLQJWKH6WHIIHV &RUSRUDWLRQURRPKHDWLQJXQLWV0RGHOV(;7,QFRPSLOLQJWKLVJXLGH6WHIIHV&RUSRUDWLRQKDVXVHGLWVEHVWMXGJHPHQW

More information

OWNER'S AND INSTALLER'S MANUAL for Double Loop (Central) Furnaces

OWNER'S AND INSTALLER'S MANUAL for Double Loop (Central) Furnaces DLF4 "Manufactured in North America" OWNER'S AND INSTALLER'S MANUAL for Double Loop (Central) Furnaces Models: DLF30B & DLF40B U.S. Pat. #5201024 Can. Pat. #2060881 1 Table of Contents General Information

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

SERVICE MANUAL IMPINGER COUNTERTOP OVEN MODEL 1300 SERIES

SERVICE MANUAL IMPINGER COUNTERTOP OVEN MODEL 1300 SERIES SERVICE MANUAL IMPINGER COUNTERTOP OVEN MODEL 1300 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Phone : (800) 374-3004 U.S. Fax: (888)

More information

SCR Power Controllers

SCR Power Controllers SCR Power Controllers Instruction Manual SCR POWER CONTROLLERS TABLE OF CONTENTS General Description and Specifications...1 Firing Modes....2 Installation and Wiring...4 Operation...9 Troubleshooting...15

More information

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for NPECOMZR00A00 ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw MicroMetl INSTALLATION INSTRUCTIONS for 0637-0311 (CPECOMZR006A00) MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence The Universal TM gas LowNOx series water heaters contain an electronic spark ignition system. The heater is connected to a 120VAC power source required by the transformer. The transformer steps down the

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL PACKAGE HEAT PUMP Models: PH242-A PH363-A PH302-A PH363-B General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual Controlled Ferroresonant Ballast (CFB) Generation #3 Manual SHAPE LLC 2105 Corporate Dr. Addison, IL 60101 (630) 620-8394 Toll Free (800) 367-5811 FAX (630) 620-0784 CONTENTS GENERAL DESCRIPTION... 3 INSTALLATION...

More information

PARTS & SERVICE MANUAL

PARTS & SERVICE MANUAL PARTS & SERVICE MANUAL Impinger Low Profile Advantage Digital Series (Electric) International Models MODELS: Please note that the model numbering system changed March 2007. The chart below shows the old

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

Irrigation Components International, Inc.

Irrigation Components International, Inc. 1500 Irrigation Components International, Inc. P.O. Box 945 Daphne, AL 36526 USA Tel: 251.626.5470 Fax: 251.447.0190 Email: icii@irricomp.com Visit us on the web: www.irricomp.com 1500 TABLE OF CONTENTS

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls UNIT OBJECTIVES After studying this unit, the reader should be able to Describe and identify power- and non-power-consuming Describe

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: WLB-A WLB-A WLB-B WLB-F General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

OWNER'S AND INSTALLER'S MANUAL for

OWNER'S AND INSTALLER'S MANUAL for CP14 "Manufactured in North America" OWNER'S AND INSTALLER'S MANUAL for FORT PLUS Forced Air Heating Systems 3100 Series 4100 Series Models: 3120, 4120, 4130, & 4140 Applicable to Software Version 140-159

More information

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater. 0 EDITION AIM MANUAL SUBMERSIBLE MORS APPLICATION INSTALLATION 60 Hz, Single-Phase and Three-Phase Motors franklinwater.com All Motors System Troubleshooting Motor Does Not Start A. No power or incorrect

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: W1AA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER Models: WAA-A WAA-A WAA-B WAA-C WAA-D WAA-F General Notes Revised and/or additional pages may be issued from time to time. A complete and

More information

BLOWER VACUUM SWITCH FAILED OPEN

BLOWER VACUUM SWITCH FAILED OPEN F1 F1 AC BLOWER VACUUM SWITCH FAILED CLOSED AC BLOWER VACUUM SWITCH FAILED CLOSED UHS If the blower vacuum switch is closed before blower start-up, the control module will not start the blower. Pre-check

More information

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number 28640996 and After Record Platter System Identification Numbers Here: Model # Serial # Table of Contents Program

More information

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTE... 3 FAULT FINDING AND DIAGNOSTICS... 3 ABBREVIATIONS... 3 PCB S... 4 OUTDOOR MAIN PCB... 4 INDOOR PCB...

More information

Modulating Furnace Information. Warning on Meter Setting - Read First!

Modulating Furnace Information. Warning on Meter Setting - Read First! Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

XENON POWER SUPPLY 4000 Watt Gladiator IV

XENON POWER SUPPLY 4000 Watt Gladiator IV XENON POWER SUPPLY 4000 Watt Gladiator IV 220 Volt Equipment Type 62-00049 Rev. February 2003 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha, Nebraska 68112 USA

More information

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING TROUBLESHOOTING for the 5 BUTTON 3109228.001 COMFORT CONTROL CENTER SYSTEM INTRODUCTION The Comfort Control Center control system can be used to operate the following Duo-Therm Units: Roof Top Air Conditioners

More information

IMPORTANT w w w w The equipment described herein is intended for installation by a qualified technician in compliance with applicable local, state, an

IMPORTANT w w w w The equipment described herein is intended for installation by a qualified technician in compliance with applicable local, state, an V17 "Manufactured in North America" OWNER'S AND INSTALLER'S MANUAL for FORT PLUS Forced Air Heating Systems Equipped with Variable Speed 3100 Series 4100 Series Models: 3120, 4120, 4130, & 4140 Applicable

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WAA-C Wall-Mount Air Conditioner with 0- VFD-High Resistance Ground Kit NOTE: For installation guidance for the 0- kit, contact Bard Technical Services at () -0. Contents Description

More information

Electric Furnace KF/KFS Series

Electric Furnace KF/KFS Series Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20-208V 24-240V 48-480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Direct drive motor Up to 3-speed motor Standard 24 Volt

More information

COOKSON OWNER'S MANUAL

COOKSON OWNER'S MANUAL COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8

More information

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE MODEL 600A 6 VOLT BATTERY CHARGER ASSOCIATE IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions for the battery charger you have purchased.

More information

XR500B Universal Voltage Regulator

XR500B Universal Voltage Regulator XR500B Universal Voltage Regulator The XR500B is a unique voltage regulator that is designed specifically for Professional Electrical Generator Service and Repair Technicians. The XR500B incorporates patented

More information

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax: INSTRUCTION MANUAL AUTO CHARGE 4000 AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 8 Amps OUTPUT BATTERY CHARGER: 40 Amps OUTPUT BATTERY SAVER: 5 Amps File: IM_091-89-12_reve.indd

More information

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is

More information

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas Installation Manual IOM-MBC-00 08-30-04 Mixing Box Control Systems Installation,, and Maintenance Manual Contents Page Introduction...1 General...1 Safety...1 Inspection...1 Mixing Box Control Systems...2

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE SENS part number: 101037 Document revision: A Engineering change number: 105073 Date: 1/13/2006 1840 Industrial Circle

More information

SLIMZONE CLASSIC /

SLIMZONE CLASSIC / SLIMZONE CLASSIC 2701-001 / 2701-006 ZONE CONTROL SYSTEM INSTALLATION AND OPERATION MANUAL TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 IMPORTANT NOTE...1 1.2 FEATURES...1 1.3 SAFETY INSTRUCTIONS...1 2. APPLICATION

More information

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part B, Section 2 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, G) Manifold 4-Port (A) 6-Port (B, C) 2-Port (S, T) Vista Standard (V) B 2-0

More information

OWNER'S AND INSTALLER'S MANUAL

OWNER'S AND INSTALLER'S MANUAL "Manufactured in North America" OWNER'S AND INSTALLER'S MANUAL for FORT PLUS Forced Air Heating Systems Equipped with Variable Speed Models: 4120, 4130, & 4140 Applicable to Software Version 2.00-2.19

More information

Solstice Electric Fryers SE Series Service Manual

Solstice Electric Fryers SE Series Service Manual Solstice Electric Fryers SE Series Service Manual L22-330 R1 (10/12) Notice In the event of problems or questions about your order, contact the Pitco Frialator factory at (603) 225-6684. In the event of

More information

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide ICM 326HN/327HN Line Voltage Head Pressure Control With built-in transformer Optional heat pump override ICM326HN ICM327HN Installation, Operation & Application Guide For more information on our complete

More information

Electronic Service Manuals

Electronic Service Manuals Electronic Service Manuals This electronic document is provided as a service to our customers. We do not create the contents of the information contained in this document. Should you have detailed questions

More information

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317) 715B CONTROL SERIES CONTROLS Instruction Manual Line Voltage DC Brushless Motor Control LT715B (IM-715B-0100) P.O. Box 10 5000 W. 106th Street Zionsville, Indiana 46077 Phone (317) 873-5211 Fax (317) 873-1105

More information

AUTO CHARGE D PUMP PLUS

AUTO CHARGE D PUMP PLUS INSTRUCTION MANUAL AUTO CHARGE D PUMP PLUS AUTOMATIC DUAL OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-9-DPP INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY:

More information

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES Article Text ARTICLE BEGINNING 1993 AIR CONDITIONING & HEAT A/C General Diagnostic Procedures Diagnosis is an important first step in A/C system servicing. To save time and effort, systems should be carefully

More information

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE SENS part number: 101194 Document revision: D DCN number: 105128 Date: 3/23/2006 1840 Industrial Circle Longmont, CO 80501 Fax: 303-678-7504 Tel: 303-678-7500

More information

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide ICM325HN Head Pressure Control with Optional Heat Pump Override Temperature sensitive control regulates head pressure Installation, Operation & Application Guide For more information on our complete range

More information

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema

More information

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER 3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols SE-3SCR-LM MANUAL MOTOR LOAD MANAGER MARCH 5, 2013 REVISION 4 MOTOR LOAD MANAGER

More information

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS ELECTRIC FENCE ENERGIZER MODEL 950 SERVICE MANUAL Service Manual for OLLI 950 Page 1/16 Date 20.10.2014 Table of Contents...1 1. IMPORTANT SAFETY INSTRUCTIONS...2 2. SPECIFICATIONS...3 3. CONSTRUCTION...4

More information

1.0 Features and Description

1.0 Features and Description 1.0 Features and Description The is an intelligent actuator designed for precise control of quarter turn valves and dampers. Using stepper motor technology, the SmartStep proportionally positions valves

More information

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET LESTRONIC II BATTERY CHARGER TAYLOR-DUNN 79-301-10 MODEL 13110-32 TYPE 24LC25-8ET AC Supply: DC Output: Battery Capacity: Specifications 120 volts, 60 Hertz, single-phase 24 volts, 32 amps Use only on

More information

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION SERIES 1000-X OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION Publication S1000X-110 VER0215-1 For information on this product and

More information

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE D2 AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-74-12 INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY 1

More information

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL LPC 20 LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-207-12 INPUT: 120 Volt, 50/60 Hz, 7 Amps OUTPUT: 20 Amps File:

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

(For serial numbers before w/ analog control)

(For serial numbers before w/ analog control) SEQUENCE OF OPERATIONS (For serial numbers before 2038616 w/ analog control) MODEL 1154-000-EA NAT. GAS 230 VAC 50 HZ. 1 PHASE MODEL 1155-000-EA LP GAS 230 VAC 50 HZ. 1 PHASE POWER SUPPLY Electrical power

More information

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE 4000 LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER Unit supplied with this display MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 5 Amps OUTPUT: 45 Amps File:

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HASKA HASKA Models: HLSKA HLSKA General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

HEATEC TEC-NOTE. Troubleshooting modulation motors

HEATEC TEC-NOTE. Troubleshooting modulation motors HEATEC TEC-NOTE Revised 4-24-07 Troubleshooting modulation motors Purpose This document provides a guide for troubleshooting burner modulation motors (Figure 1), which are commonly called mod motors. They

More information

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

ZIP Economizer Fault Detection and Diagnostics (FDD) Table Fault Detection and Diagnostics (FDD) Table Fault Detection Problem Diagnostic ction (in addition to alarm stored / transmitted) Potential Cause C Fault Code OT sensor predetermined range O damper returns

More information

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control Phone 712.722.4135 groschopp.com 420 15th St NE, Sioux Center, IA 51250 Toll-Free 800.829.4135 Email sales@groschopp.com FAX 712.722.1445

More information

STANDARD AND GROUND SWITCHED APPLICATIONS

STANDARD AND GROUND SWITCHED APPLICATIONS SNOWDOGG LIGHT REFERENCE STANDARD AND GROUND SWITCHED APPLICATIONS GENERAL REFERENCE SNOWDOGG LIGHT REFERENCE GENERAL REFERENCE 3 TROUBLESHOOTING GUIDES/PROCEDURES 6 CONNECTOR REFERENCE 12 ADAPTER HARNESS

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual Easy Start 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526. www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax: INSTRUCTION MANUAL AUTO CHARGE DUAL AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-145-12 INPUT: 120 Volt, 50/60 Hz, 3.5 Amps OUTPUT BAT 1: 10 Amps OUTPUT BAT 2: 10 Amps File: IM_091-145-12_revb.indd

More information

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: W30A, W36A General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of

More information

SERIES 700 ANALOG ELECTRONIC CONTROLS

SERIES 700 ANALOG ELECTRONIC CONTROLS SERIES 700 ANALOG ELECTRONIC CONTROLS with ACT24 Actuator Supplement INSTALLATION & OPERATION MANUAL Stock ID: IOM-700 October, 2000 2000 Environmental Technologies, Inc. Largo, FL 1.0 DEFINITIONS AND

More information

Hayward error codes and troubleshooting

Hayward error codes and troubleshooting http://waterheatertimer.org/intermatic-trippers-and-parts.html#pool 50 Hayward error codes and troubleshooting Section V. TROUBLESHOOTING http://www.hayward-pool.com/prd/in-ground-pool-manuals_10201_10551_14502_-1

More information

DCT SERIES CASE SIZE 3A FILTERED BATTERY CHARGER 12V/200A 24V/ A 48V/100A 120V/50A 240V/25A OPERATION & MAINTENANCE GUIDE

DCT SERIES CASE SIZE 3A FILTERED BATTERY CHARGER 12V/200A 24V/ A 48V/100A 120V/50A 240V/25A OPERATION & MAINTENANCE GUIDE DCT SERIES CASE SIZE 3A FILTERED BATTERY CHARGER 12V/200A 24V/150-200A 48V/100A 120V/50A 240V/25A OPERATION & MAINTENANCE GUIDE SENS part number: 101137-3 Document revision: B DCN number: 105286 Date:

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

PAGE Both power cords must be connected & powered to operate the E-TES 120.

PAGE Both power cords must be connected & powered to operate the E-TES 120. PAGE 1 This document outlines questions to ask and components to check during E-TES 120 troubleshooting. More detailed troubleshooting procedures are available in the E-TES 120 Troubleshooting Guide. 1.

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Battery 12V battery system 24V battery system Type Type Code Bulk Floating Bulk Floating Vented 01 14.3 V 13.2 V 28.6 V 26.4 V Sealed 02 14.3 V

More information

MODEL 9520 & 9520GS 6/12 VOLT, 0-20 AMP - BATTERY CHARGER OWNER'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

MODEL 9520 & 9520GS 6/12 VOLT, 0-20 AMP - BATTERY CHARGER OWNER'S MANUAL IMPORTANT SAFETY INSTRUCTIONS MODEL 9520 & 9520GS 6/12 VOLT, 0-20 AMP - BATTERY CHARGER OWNER'S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS: This manual contains important safety and operating instructions for the

More information

HEATER LOW/NO HEAT WHEN TEMPERATURE Article No. KNOB IS SET AT FULL HEAT

HEATER LOW/NO HEAT WHEN TEMPERATURE Article No. KNOB IS SET AT FULL HEAT HEATER LOW/NO HEAT WHEN TEMPERATURE Article No. KNOB IS SET AT FULL HEAT 94-20-16 FORD: 1992-1994 BRONCO, F-150-350 SERIES ISSUE Some vehicles may exhibit a low or no heat condition when the temperature

More information

GENERAL <ELECTRICAL>

GENERAL <ELECTRICAL> 00E-1 GROUP 00E GENERAL CONTENTS HARNESS CONNECTOR INSPECTION................................. 00E-2............. 00E-6................. 00E-6 TROUBLESHOOTING STEPS.......... 00E-6 INFORMATION

More information

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual EasyStart 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro-Air Corporation www.microair.net 124 Route 526 Phone (609) 259-2636 Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information

GENERAL <ELECTRICAL>

GENERAL <ELECTRICAL> 00E-1 GROUP 00E GENERAL CONTENTS HARNESS CONNECTOR INSPECTION................... 00E-2............. 00E-6................. 00E-6 TROUBLESHOOTING STEPS.......... 00E-6 INFORMATION FOR DIAGNOSIS.......

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging

More information

ELECTRICAL / GENERAL INFORMATION

ELECTRICAL / GENERAL INFORMATION ELECTRICAL / GENERAL INFORMATION General Information Reading Electrical Schematics The schematic is made up of individual circuits laid out in a sequence of related functions. It is formatted with all

More information

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE 12 HO AUTOMATIC SINGLE OUTPUT BATTERY CHARGER MODEL #: 091-170-6 MODEL #: 091-170-12 MODEL #: 091-170-24 File: IM_091-170-xx_revd.indd Rev: D Revised By: MFG Date: 10-23-2013

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: HAA-A HAA-A H0AA-A HAA-A HAA-B HAA-B H0AA-B HAA-B Contents Description Page Cabinet Components Exploded View... Usage List... Usage

More information

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema

More information

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MP-5200 Series Electronic Hydraulic Actuator General Instructions Application The MP-5200 Series actuators are for the electronic

More information

Page 2. Pitot tube anti-ice. Windshield Anti-ice Components. Propeller Anti-ice Components. Wing boot anti-ice pneumatic components

Page 2. Pitot tube anti-ice. Windshield Anti-ice Components. Propeller Anti-ice Components. Wing boot anti-ice pneumatic components Ice & Rain Trainer Component Location Page 2 Pitot tube anti-ice Propeller Anti-ice Components Windshield Anti-ice Components Wing boot anti-ice pneumatic components Control and Indicating Components 110

More information

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS NOTE TO INSTALLER The words SHALL and MUST indicate a requirement which is essential to satisfactory and safe product

More information

ELECTRICAL TABLE OF CONTENTS

ELECTRICAL TABLE OF CONTENTS ELECTRICAL TABLE OF CONTENTS Electrical Table of Contents General Information...205 Reading Electrical Schematics...205 Theory Of Operation Information...206 Diagnostic Information...206 Wire Color Abbreviation

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVEN MODEL 1100-000-A SERIES (SN 2038615 & BELOW) SERVICE MANUAL Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United

More information

XENON POWER SUPPLY Watt

XENON POWER SUPPLY Watt XENON POWER SUPPLY 3000-5000 Watt 220 Volt Equipment Type 62-00016 62-00017 62-00004 (Export) Rev. February 2006 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha,

More information

LF Series At A Glance

LF Series At A Glance LF Series Spring Return Direct Coupled Actuator Minimum 35 in-lb Torque For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W30H-A W30H-B W30H-C WALL MOUNTED PACKAGED HEAT PUMP W30HDA W30HDB W30HDC Models: W36H-A W36H-B W36H-C W36HDA W36HDB W36HDC General Notes Revised and/or additional pages may be

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1988 Toyota Celica 1988 Automatic A/C-Heater Systems Celica * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system, use only approved refrigerant recovery/recycling

More information

XENON POWER SUPPLY Compact Model 220 Volt Equipment Type

XENON POWER SUPPLY Compact Model 220 Volt Equipment Type XENON POWER SUPPLY Compact Model 220 Volt Equipment Type 62-80106 62-80108 62-80109 62-80113 Rev. August 2001 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha, Nebraska

More information

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information