OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

Size: px
Start display at page:

Download "OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E"

Transcription

1 Nordson Corporation OPERATOR S CARD P/N 32 96E Select Series H-400 Hot Melt Dispensing Guns Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result in the uncontrolled release of hot melt that can cause personal injury. Refer to the melter-specific product manual for information on relieving hydraulic pressure. WARNING: Molten material! Wear eye or face protection, clothing that protects exposed skin, and heat-protective gloves when servicing equipment that contains molten hot melt. Even when solidified, hot melt can still cause burns. Failure to wear appropriate personal protective equipment can result in personal injury. WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment can result in injury, including death, to themselves and others, and damage to the equipment. CAUTION: Risk of equipment damage. Nordson Corporation recommends turning off the gun air supply during system statup to prevent unexpected pressure buildup in the gun module and manifold caused by the expansion of the cold adhesive as it melts. Description/Intended Use Nordson Series H-400 guns are used to apply thermoplastic hot melt materials to a product. Polyurethane-reactive (PUR) and high-temperature polyamide adhesives can negatively affect gun performance and durability. The H-400 gun product line includes single- and multi-module configurations. H-400 guns provide continuous operation and consistent adhesive output, minimizing delays. H-400 gun modules for ITW Dynatec and Robatech systems are heated by replaceable heater elements that are controlled by a Pt-00 platinum temperature sensor (ITW Dynatec) or a negative temperature coefficient (NTC) thermistor (Robatech). The sensor and thermistor allow precise temperature sensing and control of gun temperature by the ITW Dynatec or Robatech unit. A variety of nozzle sizes may be used with H-400 guns. Issued 3/03 H-400 Gun Components. Solenoid valve (Nordson) 2. Pipe nipple 3. Mounting clamp 4. Insulator Cordset 6. Gun manifold 7. Gun-to-hose fitting 8. Gun module A 42-H400-OC-02

2 Specifications Operating temperature Item Specification Note Working hydraulic pressure 230C (450F) maximum 0.34 MPa (,500 psi) maximum Operating air pressure 340 to 480 kpa (40 to 70 psi) A Operating speed Nozzles Electrical service Approvals and certifications exceeds 4,200 cycles per minute 238 XXX, right-angle, and Saturn precision nozzles 240 VAC, 50/60 Hz 200 VAC, 50/60 Hz (optional for low-voltage areas) UL/TUV/CUL/CE NOTE A: Use dry, regulated, and unlubricated air for consistent gun operation. Installation and Set-up Guidelines Use the following installation guidelines to achieve optimum gun performance. Mounting Mount the gun so that the nozzle is no more than 3 mm (0.5 in.) from the substrate. Connections Only use one fitting to connect the hose to the gun. Insulate the fitting between the hose and gun. Install integral filter guns with a minimum 94 mm (3.70 in.) clearance above the gun manifold so that the filter assembly can be removed. Install integral and Saturn filter guns with sufficient clearance at the rear of the gun to allow operation of the manifold drain valve. Keep the pipe nipple connecting the solenoid valve to the gun to less than 76 mm (3 in.) in length. Solenoid Valves Only use solenoid valves rated above 0.5 Cv and with a service temperature above 85C (85F). Install the gun with sufficient clearance to the rear or sides of the gun to allow for removal of the manifold body cover or endplates. Third-party solenoid valves must be capable of being manually triggered at the gun. Use Nordson solenoid valves for optimum performance. Mount the gun on a rigid support that is isolated from external vibrations and that prevents the gun from rotating. Insulate the gun from the support, using the insulator provided with the gun. Only use clean, dry, and un-lubricated air. Ensure that the plant air supply and regulator provide a minimum of 340 kpa (50 psig) to the gun solenoid valve. NOTE: Nordson Corporation recommends selecting a nozzle with orifice and length that allows the guns to operate above 3. MPa (450 psi). Set the temperature compensation factor on Robatech melters to 7.5 to ensure that the guns temperature is correctly detected. 42-H400-MA-02 2 Issued 3/03

3 Troubleshooting. No adhesive flow from any module of a multi-module gun or from a single-module gun Adhesive level low No input power Melter, hose, or gun temperature setting is too low System is not at operating temperature Insufficient air pressure to the piston pump or Melter motor not operating No air supply to the solenoid valve Solenoid valve has failed Hose is clogged Add adhesive. Connect power to the melter and auxiliary devices. Make sure that all disconnect switches or circuit breakers are on. Adjust the setting. Refer to the melter product manual. Verify that the READY light is on and the hot melt is molten. Verify air pressure by flushing the filter. Refer to the melter product manual. or Verify motor operation. Refer to the melter product manual. Check the plant air supply pressure. Check the solenoid valve and replace it if defective. Replace the hose. Nozzle is clogged Module has failed Dirty or faulty triggering device Faulty encoder Check the nozzle. Check for correct module operation. Clean or replace the triggering device. Test the encoder and replace if defective. 2. No adhesive flow from some modules in a multi-module gun 3. Adhesive or air flows from bleed hole 4. Modules not triggering at the same time on multi-module gun 5. Gun fails to heat or underheats Nozzle is clogged Module has failed Air or adhesive seals have failed. Gun loading screw is not properly set Module has failed No power Gun temperature setting is too low Check the nozzle. Check the module for correct operation. Replace or rebuild the module. Refer to Repair and Parts. Contact Nordson technical support. Check the module for correct operation. Check that the melter is on. Refer to the melter product manual. Adjust the temperature setting. Refer to the melter product manual. Issued 3/ H400-OC-02

4 Cleaning Nozzles Gun nozzles may become clogged when char, a by-product of overheating the hot melt, becomes lodged in the nozzle. The use of inline or integral filters will significantly reduce nozzle clogging. CAUTION: Do not attempt to clean zero- or reduced-cavity modules. Replace or exchange clogged zero- or reduced-cavity modules. Contact your Nordson representative for information on Nordson s Trade Plus program.. Ensure that the gun is at operating temperature. 2. Disable the gun. Refer to Safety. 3. See Figure. Remove the nozzle. WARNING: Risk of fire. Do not heat Nordson Type R fluid above 245C (475F). Use only an industrial grade, regulated, electrical heating devices that is designed to heat industrial fluids. Personal injury or property damage can result if Type R cleaning fluid is heated with an open flame or an unregulated heating device. 4. Soak the nozzle(s) in Nordson Type R cleaning fluid that has been heated above the melting point of the hot melt. 5. Remove the nozzle(s) from the cleaning fluid. CAUTION: Use the correct size precision pin probe to clean Nordson nozzles. The use of non-precision or incorrectly sized probes may damage the nozzle. The Nordson nozzle cleaning kit (P/N 90 95) contains a variety of probe sizes. 6. At the outlet of the nozzle, insert a correctly sized cleaning probe. 7. With a clean cloth, firmly grip the cleaning probe, and then pull the probe out of the nozzle, wiping the probe clean Reinstall the nozzle(s). Tighten the nozzle(s) to 4.5 Nm (40 in.-lb). Parts To order parts, contact the Nordson Customer Service Center or your local Nordson representative. Use the following parts lists to describe and locate parts correctly. Gun Cordset and Sensor Item Dynamini/ melt Gun Dynapro/ plus Gun Robatech Gun Description Quantity Note Cordset, gun, 22 in. A Cordset, gun, 24 in. A NOTE A: Includes the sensor or thermistor. To replace the sensor or thermistor, order a replacement cordset. 42-H400-MA-02 4 Issued 3/03

5 Gun Manifold and Heater Dynamini /melt Gun Dynapro/ plus Gun Robatech Gun Description Manifold Part Heater Part Note H-40, 240 VAC H-402, 240 VAC, 2.3 in. center-line H-402, 240 VAC, 0.88 in. center-line, low-profile A, B H-404, 240 VAC, 0.88 in. center-line H-404, 240 VAC, 0.88 in. center-line, low-profile A, C NOTE A: Requires two heaters. B: Requires one () each of gaskets part and part C: Requires one () each of gaskets part and part HEATER HEATER SENSOR ROBATECH GUN CORDSET PINS ITW DYNATEC GUN CORDSET PINS Series H-400 Gun Cordset, Manifold, and Heater. Cordset with sensor/thermistor 2. Gun manifold 3. Heater A Issued 3/ H400-OC-02

6 Parts (contd) Gun Module and Solenoid Valve Item Part Description Quantity Note Gun module, H-400, air-open, spring-close A Gun module O-ring, 0.28 ID x 0.70 in. 2 B Solenoid valve,.00 Cv, 24 VDC, / 4 NPT, quick-disconnect, light, piloted Solenoid valve,.00 Cv, 24 VDC, / 4 NPT, quick-disconnect, piloted Solenoid valve,.00 Cv, 24 VDC, / 4 NPT, quick-disconnect, light, piloted, water wash Solenoid valve,.00 Cv, 20 VDC, / 4 NPT, quick-disconnect, piloted Solenoid valve,.4 Cv, 24 VDC, / 4 NPT, quick-disconnect, piloted Solenoid valve,.4 Cv, 24 VDC, / 4 NPT, quick-disconnect, light, piloted Muffler, air, / 8 NPT 2 C Silencer, / 8 NPT x 2.3 in. long 2 C Fitting, quick-disconnect, / 4 NPT D NOTE A: This kit includes two O-rings and two screws (to attach the gun module to the gun manifold). B: This kit includes 0 O-rings. C: Most guns are shipped with air mufflers that are used to reduce solenoid valve exhaust noise. If desired, you can use silencers instead of air mufflers. Silencers provide extended service life. D: If desired, you can install this quick-disconnect fitting to allow easy removal of a solenoid valve ÎÎÎ A Series H-400 Gun Module and Solenoid Valve Parts 42-H400-MA-02 6 Issued 3/03

7 DECLARATION OF CONFORMITY (For CE-Certified Select Series H-400 Hot Melt Dispensing Guns) APPLICABLE DIRECTIVES: 73/23/EEC (Low Voltage Directive) PRINCIPLES: This product has been manufactured according to good engineering practice. This product conforms to the directive and standards described here. STANDARDS USED TO VERIFY COMPLIANCE: EN60204 Nordson Corporation Westlake, Ohio Donald J. McLane, Senior Vice President Date: Issued 3/ H400-OC-02

8 Dynamini, Dynamelt, Dynapro, Dynaplus and Robatech are trademarks of ITW Dynatec, Inc. Original copyright date 999. Nordson and the Nordson logo are registered trademarks of Nordson Corporation. 42-H400-MA-02 8 Issued 3/03

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D Nordson Corporation OPERATOR S CARD P/N 321 198D Select Series H-440 Hot Melt Dispensing Guns Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet Instruction Sheet Replacing a Gun RTD WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an out-in filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

SP30 10:1 Piston Pump

SP30 10:1 Piston Pump Instruction Sheet P/N SP30 10:1 Piston Pump 1. Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and

More information

Installing an H-200 Integral Right-Angle Module

Installing an H-200 Integral Right-Angle Module Instruction heet P/N 187 723A Installing an H-200 Integral Right-Angle Module WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules. 9-1 Section 9 NOTE: This section applies to applicators with bead or slot modules. Table of Contents... 9-1 Introduction... 9-3 Overview... 9-7 Service... 9-9 Adjusting a ClassicBlue Zero-Cavity... 9-9

More information

Installation Instructions for Series 3100V Low Level Indicator

Installation Instructions for Series 3100V Low Level Indicator Instruction Sheet P/N Installation Instructions for Series 3100V Low Level Indicator WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

Solenoid Valve Installation Kit

Solenoid Valve Installation Kit Instruction Sheet P/N 7 5A Solenoid Valve Installation Kit WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related

More information

Preventive Maintenance for Pail Melters

Preventive Maintenance for Pail Melters Instruction Sheet P/N Preventive Maintenance for Pail Melters 1. Introduction These procedures are recommended in addition to the standard preventive maintenance. Use them to keep yourvista controlled

More information

E-200 Module Service Kit

E-200 Module Service Kit Instruction Sheet E-200 Module Service Kit 1. Introduction These instructions describe how to remove and replace the E-200 module. The instructions include the following: S S S S Safety Unit Preparation

More information

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion Instruction Sheet P/N 106501A03 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment.

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with a Universal in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with an in-out filter. Table of Contents Filter...................................................... 10-1 Introduction................................................

More information

Blow Off Valve Retrofit Kit

Blow Off Valve Retrofit Kit Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..

More information

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A Nordson Corporation OPERATOR S CARD P/N 052644A VL400 Melters Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

Installing the Integral Platen Blow Off Valve

Installing the Integral Platen Blow Off Valve Instruction Sheet Installing the Integral Platen Blow Off Valve WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all

More information

5000 Gerotor Pump Service Instructions

5000 Gerotor Pump Service Instructions Instruction Sheet P/N 237569B WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction This

More information

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia eries H-400 Guns Customer Product Manual Part NORDON CORPORATION D Duluth, Georgia www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information, comments

More information

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun Instruction Sheet P/N 237494_02 Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun WARNING! Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01 Section 9 NOTE: This section applies to applicators with CC200 modules. 9-0 Table of Contents i Table of Contents Section 9 1. Introduction............................................... 9-1 2. Specifications.............................................

More information

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter. Filter 10-1 Section 10 Filter NOTE: This section applies to applicators with a threaded filter. Table of Contents Filter... 10-1 Introduction... 10-3 Filter Overview... 10-3 Filter Service... 10-4 Relieving

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules. 9-1 Section 9 NOTE: This section applies to applicators with CF200PAD right-angle modules. Table of Contents.................................................... 9-1 Introduction................................................

More information

Standard and Conical AN Series Air Spray Nozzles

Standard and Conical AN Series Air Spray Nozzles Instruction Sheet P/N 107967E Standard and Conical AN Series Air Spray Nozzles Introduction The Nordson air spray nozzles described in this instruction sheet are categorized by their type of spray pattern:

More information

Series 3900/M Pump Retrofit Kit

Series 3900/M Pump Retrofit Kit Instruction Sheet P/N Series 900/M Pump Retrofit Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3860 3890 3930 3960 All Piston (D) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista

More information

Spray Pressure Control Manifold

Spray Pressure Control Manifold Instruction Sheet P/N 0870G0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction The

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with M-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

Pro-Swirl Manifold Air Heater

Pro-Swirl Manifold Air Heater Instruction Sheet P/N 16107 01 Description The Pro-Swirl manifold heats air coming from the Pro-Swirl coalescent filter. The heater air then flows through the internal passages of the Pro-Swirl to maintain

More information

Auto-Flo Air-Assist Automatic Dispensing Valve

Auto-Flo Air-Assist Automatic Dispensing Valve Auto-Flo Air-Assist Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its

More information

Spray Pressure Control Manifold

Spray Pressure Control Manifold Instruction Sheet P/N 0870-0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction The

More information

NOZZLETECH INC. INSTRUCTION MANUAL CEV00 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

NOZZLETECH INC. INSTRUCTION MANUAL CEV00 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA NOZZLETECH INC. 3208C EAST COLONIAL DRIVE ORLANDO, FL 32803 USA INSTRUCTION MANUAL CEV00 01/31/2013 NOZZLETECH CEV00 SERIES COMPACT ELECTRIC VALVES FOR EXTRUSION RELATED PATTERNS WARNING: The fluid supply

More information

Maintenance. Part A, Section 5. This section covers the following unit configurations.

Maintenance. Part A, Section 5. This section covers the following unit configurations. Part A, Section 5 This section covers the following unit configurations. Model 3100V 3400V 3830V 3860V 3890V 3930V Voltage 1, 2 Pump AC Gear (K or L) Manifold 4-Port (J)) Control Vista Standard (V) Vista

More information

OPERATIONS AND SERVICE MANUAL MOD-PLUS TM DYNA BF HOT MELT ADHESIVE APPLICATOR HEADS

OPERATIONS AND SERVICE MANUAL MOD-PLUS TM DYNA BF HOT MELT ADHESIVE APPLICATOR HEADS OPERATIONS & SERVICE MANUAL #40-31 Revised 8/1/13 OPERATIONS AND SERVICE MANUAL MOD-PLUS TM DYNA BF HOT MELT ADHESIVE APPLICATOR HEADS IMPORTANT! - READ ALL INSTRUCTIONS BEFORE OPERATING THIS EQUIPMENT

More information

11-1 Electrical System NOTE: Table of Contents Electrical System

11-1 Electrical System NOTE: Table of Contents Electrical System Electrical System - Section Electrical System NOTE: This section applies to applicators with Universal C-style cordsets. Table of Contents Electrical System........................................... -

More information

Instructions-Parts 3A2805M. environments psi (10.3 MPa, 103 bar) Maximum Working Fluid Pressure 80 psi (0.5 MPa, 5.5 bar) Maximum Air Pressure

Instructions-Parts 3A2805M. environments psi (10.3 MPa, 103 bar) Maximum Working Fluid Pressure 80 psi (0.5 MPa, 5.5 bar) Maximum Air Pressure Instructions-Parts InvisiPac GS35 Plug-Free Hot Melt Applicator 3A2805M EN For dispensing hot melt adhesive. For professional use only. Not for use in waterwash environments. Not approved for use in explosive

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A

More information

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules. 9- Section 9 NOTE: This section applies to applicators with MB200 modules. Table of Contents.................................................... 9- Introduction................................................

More information

TCU Flushing Manifold and RTD Installation

TCU Flushing Manifold and RTD Installation Instruction Sheet P/N 1614041-01 This instruction is for installing temperature control unit (TCU) flush manifold and RTD assembly onto the heat exchanger for both new systems and existing systems. Follow

More information

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV Generation II Pump Panel Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V Part B, Section 1 This section covers the following unit configurations. Model Voltage Pump Manifold Control 3100V 3400V 3500V 3700V All Piston (E) 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Standard

More information

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V Part B, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. 3500V 3700V 3800V 3900V All Piston (F) 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Standard

More information

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit Instruction Sheet 108 792A Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit 1. Description Use this rebuild kit to service the following modules: S Normally Open H200 (N.O. H200) Module -- P/N

More information

E-200 O-rings Service Kit

E-200 O-rings Service Kit Instruction Sheet E-00 O-rings Service Kit. Introduction These instructions describe how to replace the o-rings in the E-00 gun module. It is necessary to remove and disassemble the module when replacing

More information

Pattern Air Control Kit (PACK)

Pattern Air Control Kit (PACK) Instruction Sheet P/N 044445B0 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or

More information

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0

More information

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B Sure Coat Modular Gun Control System Part B: Pneumatic Modules Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800)

More information

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets. Electrical System - Section Electrical System NOTE: This section applies to applicators with C-style cordsets. Table of Contents Electrical System........................................... - Introduction................................................

More information

OPERATIONS AND SERVICE MANUAL MOD-PLUS TM ELECTRIC HOT MELT ADHESIVE APPLICATOR HEADS

OPERATIONS AND SERVICE MANUAL MOD-PLUS TM ELECTRIC HOT MELT ADHESIVE APPLICATOR HEADS ITW Dynatec An Illinois Tool Works Company 31 Volunteer Drive Hendersonville, TN 37075 USA Telephone 615.824.3634 FAX 615.264.5222 OPERATIONS & SERVICE MANUAL #40-30 Revised 4/20/07 Adhesive Application

More information

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA NOZZLETECH INC. 3208C EAST COLONIAL DRIVE ORLANDO, FL 32803 USA INSTRUCTION MANUAL CEV10 01/31/2013 NOZZLETECH CEV10 SERIES COMPACT ELECTRIC VALVES FOR SPRAYING ROUND PATTERNS WARNING: The fluid supply

More information

Prodigy HDLV Pump Manifold and Circuit Board

Prodigy HDLV Pump Manifold and Circuit Board Prodigy HDLV Pump Manifold and Circuit Board Customer Product Manual Issued 05/08 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available

More information

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Auto-Flo Panel Reinforcement Automatic Dispensing Valve Auto-Flo Panel Reinforcement Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries

More information

OPERATIONS AND SERVICE MANUAL BF MICROBEAD ADHESIVE APPLICATOR HOT MELT ADHESIVE APPLICATOR

OPERATIONS AND SERVICE MANUAL BF MICROBEAD ADHESIVE APPLICATOR HOT MELT ADHESIVE APPLICATOR OPERATIONS & SERVICE MANUAL #40-66 Revised 4/1/13 OPERATIONS AND SERVICE MANUAL BF MICROBEAD ADHESIVE APPLICATOR HOT MELT ADHESIVE APPLICATOR IMPORTANT! READ ALL INSTRUCTIONS BEFORE OPERATING THIS EQUIPMENT

More information

Prodigy HDLV System Troubleshooting - Generation III

Prodigy HDLV System Troubleshooting - Generation III Prodigy HDLV System Troubleshooting - Generation III Instruction Sheet P/N 1081071-05 Use the procedures listed in this document to isolate and correct common problems with Prodigy HDLV Systems. Refer

More information

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B Sure Coat Modular Gun Control System Part D: Gun Purge Module Customer Product Manual Issued 4/0 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 4-919

More information

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA Installation and Maintenance Instructions Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

One-Gun Add-On Kit For Smart-Coat Controllers

One-Gun Add-On Kit For Smart-Coat Controllers Instruction Sheet P/N One-Gun Add-On Kit For Smart-Coat Controllers 1. Introduction This document contains procedures for installing a one-gun add-on kit to your Smart-Coat Controller. For additional information,

More information

InvisiPac GS35 Plug-Free HotMeltApplicator

InvisiPac GS35 Plug-Free HotMeltApplicator Instructions-Parts InvisiPac GS35 Plug-Free HotMeltApplicator 3A2805B EN For dispensing hot melt adhesive. For professional use only. Not approved for use in explosive atmospheres or hazardous locations.

More information

Paint/Solvent/Dump Valve and Flow-Through Valve

Paint/Solvent/Dump Valve and Flow-Through Valve Instruction Sheet P/N 08573D Paint/Solvent/Dump Valve and Flow-Through Valve. Description See Figure. The paint/solvent/dump valve is a normally-closed valve that opens to trigger and/or dump coating material.

More information

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11 Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified

More information

Model AD-29A Automatic Air Spray Gun and Can Marking System

Model AD-29A Automatic Air Spray Gun and Can Marking System Model AD-29A Automatic Air Spray Gun and Can Marking System Part 07 979A NORDSON CORPORATION. AMHERST, OHIO. USA 2-454d TECHNICAL PUBLICATION Nordson Corporation Finishing Equipment Division ISSUED 4/85

More information

SERIES H-200 HOT MELT GUNS. Durable, high-speed automatic hot melt guns provide extensive pattern flexibility.

SERIES H-200 HOT MELT GUNS. Durable, high-speed automatic hot melt guns provide extensive pattern flexibility. SERIES H-200 HOT MELT GUNS Durable, high-speed automatic hot melt guns provide extensive pattern flexibility. Innovative gun designs allow more flexibility and control of bead size, shape and placement.

More information

EcoLiner Compound Gun

EcoLiner Compound Gun EcoLiner Compound Gun Customer Product Manual Issued 3/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit Instruction Sheet P/N 10874C AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit 1. Description Use the solvent-based to waterborne conversion kit to convert your Nordson AN-8 Plus Air Spray

More information

World Gun Series. Customer Product Manual Part C. Issued 11/03. NORDSON CORPORATION DULUTH, GEORGIA USA

World Gun Series. Customer Product Manual Part C. Issued 11/03. NORDSON CORPORATION DULUTH, GEORGIA USA World Gun Series Customer Product Manual Issued 11/03 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,

More information

Upgrading the Sure Coat Modular Gun Control System

Upgrading the Sure Coat Modular Gun Control System Instruction Sheet P/N 007365B Upgrading the Sure Coat Modular Gun Control System WARNING: Read the Safety section in the Sure Coat Modular Gun Control System manual before performing any of the following

More information

Miniature Soft Seat Fluid Pressure Regulator

Miniature Soft Seat Fluid Pressure Regulator Instruction Sheet P/N 1. Description The Nordson miniature soft seat fluid pressure regulator is designed for use with hydraulic and pneumatic medias. The regulator body and wetted parts are constructed

More information

Installing the Low Level Indicator (P/N or P/N )

Installing the Low Level Indicator (P/N or P/N ) Instruction Sheet Installing the Low Level Indicator (P/N 276 176 or P/N 276 4) 1. Introduction There are two Low Level indicator kits, one for flat bottomed tanks and one for the new finned tanks. P/N

More information

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6 Part B, Section 5 Model 500 Voltage, Pump Piston (E) Manifold -Port (B or C) -Port (S or T) Control MultiScan (M) 000Nordson Corporation -000 Issued /00 B 5-0 -000 Issued /00 000 Nordson Corporation B

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 300V 3400V 3500V Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B or C) -Port (S or T) Vista Pattern

More information

Encore HD Powder Spray System with Prodigy Pump Cabinet

Encore HD Powder Spray System with Prodigy Pump Cabinet Encore HD Powder Spray System with Prodigy Pump Cabinet Customer Product Manual Part 604979-06 Issued 05/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at

More information

E-350 Electric Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA

E-350 Electric Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA E-350 Electric Gun Customer Product Manual Part 237 495A NORDON CORPORATION D AMHERT, OHIO D UA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address

More information

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00 Part B, Section 5 This section covers the following unit configurations Model 5 Voltage. Pump Piston (E,) Manifold -Port (A) Control UniScan Nordson Corporation Issued / B 5- Issued / 999 Nordson Corporation

More information

Inverted High Pressure Fluid Filters

Inverted High Pressure Fluid Filters Instruction Sheet P/N 33290-03 Description See Figure. Nordson high-pressure fluid filters prevent nozzle-plugging by filtering contaminants out of coating materials. These stainless steel, wall-mounted

More information

Prodigy HDLV Pump. Customer Product Manual Part A02

Prodigy HDLV Pump. Customer Product Manual Part A02 Prodigy HDLV Pump Customer Product Manual Issued 1/07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G) Part B, Section 1 This section covers the following unit configurations. Model 3100 3400 3500 Voltage 1, 2 Pump Piston (E, F, or G) Manifold 4-Port (A) 6-Port (B or C) Control UniScan (1) B 1-0 B 1-1 Section

More information

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover Description NOTE: Throughout this document, the Rhino SD2/XD2 Type-H Control Modules are referred to as the Control Module. See Figure 1. The Control Module (1) provides the pneumatic operating functions

More information

Sure Coat 90 Degree Spray Extension

Sure Coat 90 Degree Spray Extension Instruction Sheet P/N 076A Sure Coat 90 Degree Spray Extension Description The 90 Degree Spray Extension is used on Sure Coat Automatic Powder Spray Guns. It allows powder to be sprayed at right angles

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder Instruction Sheet P/N 6480-0 Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in

More information

Nordson Airless Nozzle Tester

Nordson Airless Nozzle Tester Instruction Sheet P/N Nordson Airless Nozzle Tester. Introduction The Nordson airless nozzle tester is used to test the flow rate of flanged airless nozzles. The results of the tests can be used to determine

More information

Nordson/Drexelbrook Material Level Control Kit

Nordson/Drexelbrook Material Level Control Kit Nordson/Drexelbrook Material Level Control Kit NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Series H-200 Guns. Customer Product Manual Part K. Issued 8/05. NORDSON CORPORATION DULUTH, GEORGIA USA

Series H-200 Guns. Customer Product Manual Part K. Issued 8/05. NORDSON CORPORATION DULUTH, GEORGIA USA eries H-200 Guns Customer Product Manual Issued 8/05 NORDON CORPORATION DULUTH, GEORGIA UA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests for information,

More information

Series 3000V Low Level Indicator

Series 3000V Low Level Indicator Instruction Sheet P/N 237 473A Series 3000V Low Level Indicator 1. Introduction The low level indicator sends a signal to an external device when the adhesive level in the applicator s tank is low. The

More information

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07 RediCoat by Nordson Hopper and VBF Dolly Systems Customer Product Manual Part 1082648A Issued 10/07 This document is subject to change without notice. Nordson Corporation Amherst, Ohio USA 2 Table of Contents

More information

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N Instruction heet eries AD-31 Handgun wivel Connector Replacement Kit P/N 238 808 and P/N 238 809 1. Description This instruction sheet contains procedures for replacing the swivel connector on eries AD-31

More information

Rhino SD/XD Depressurization Modules for Electric Changeover Controls

Rhino SD/XD Depressurization Modules for Electric Changeover Controls Instruction Sheet 1041-04 Rhino SD/XD Depressurization Modules for Electric Changeover Controls Description Rhino SD/XD depressurization modules relieve material pressure by flowing material under the

More information

Air Spray Proportioning Valve

Air Spray Proportioning Valve Instruction Sheet P/N Air Spray Proportioning Valve. Installation The air spray proportioning valve provides close regulation of air spray characteristics for air spray versions of the Pro-Flo dispensing

More information

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2

More information

Prodigy HDLV Manual System Installation Instructions

Prodigy HDLV Manual System Installation Instructions Prodigy HDLV Manual System Installation Instructions Instruction Sheet P/N 1062384C WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

Encore HD Automatic System Standalone Pump Stand

Encore HD Automatic System Standalone Pump Stand Encore HD Automatic System Standalone Pump Stand Customer Product Manual Part 6 0 Issued /7 For parts and technical support, call the Finishing Customer Support Center at (00) 4-99. This document is subject

More information

Prodigy HDLV Generation II Manual System Installation Instructions

Prodigy HDLV Generation II Manual System Installation Instructions Prodigy HDLV Generation II Manual System Installation Instructions Instruction Sheet P/N 1081707A WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Instructions H EN. See page 6 for models, approval information and working pressure ratings. Patent Pending

Instructions H EN. See page 6 for models, approval information and working pressure ratings. Patent Pending Instructions InvisiPac GM00 Plug-Free Hot Melt Applicator 334627H EN For dispensing hot melt adhesive. For professional use only. Not approved for use in explosive atmospheres or hazardous locations. Important

More information

High Flow and 100 PLUS FB Powder Pumps

High Flow and 100 PLUS FB Powder Pumps Instruction Sheet P/N 07 987C High Flow and 00 PLUS FB Powder Pumps. Description The Nordson High Flow and 00 PLUS Powder Pumps are highly efficient venturi-type pumps designed primarily for pipe-coating

More information

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1 5-1 Section 5 WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. NOTE: is an important

More information

0 900 psi Pressure-Reducing Diaphragm Regulator

0 900 psi Pressure-Reducing Diaphragm Regulator Instruction Sheet P/N 009506-09 0 900 psi Pressure-Reducing Diaphragm Regulator Description The Nordson 0 900 psi diaphragm regulator reduces high primary pressures to lower secondary pressures. It is

More information

T1-Titanium Non-HVLP Spray Gun

T1-Titanium Non-HVLP Spray Gun T1-Titanium Non-HVLP Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

E400 Electric Applicator

E400 Electric Applicator E400 Electric Applicator Customer Product Manual Issued 7/05 NORDSON CORPORATION DAWSONVILLE, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests

More information

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

PatternJet Adhesive Dispensing Gun

PatternJet Adhesive Dispensing Gun PatternJet Adhesive Dispensing Gun Customer Product Manual Issued 3/06 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter manual. Nordson Corporation welcomes requests

More information