Higher DC pressure rating 80% reduction in power consumption Built-in surge suppression 3-year coil warranty Class I, Division 2 coils available

Size: px
Start display at page:

Download "Higher DC pressure rating 80% reduction in power consumption Built-in surge suppression 3-year coil warranty Class I, Division 2 coils available"

Transcription

1 4 igher pressure rating 80% reduction in power consumption uilt-in surge suppression 3-year coil warranty lass, ivision 2 coils available

2 Redat Next eneration lectronically nhanced Solenoid Valve Technology Redat Next eneration is the future of solenoid valve technology, designed and manufactured to provide new capabilities. The Next eneration of solenoid valves provides lower operating cost, and represents an advancement in the performance, reliability, and ruggedness that you have come to expect from ASO. lectronics technology to manage power Redat Next eneration valves use electronics technology to manage power, providing a new standard of operation. The solenoid incorporates a power management circuit providing lower power consumption, enhanced pressure and flow ratings, and electrical surge suppression to both the solenoid and electronic controls. Low power The new solenoid draws only 1.0 watt of power for 12-24V and 1.5 watts for V A/, V A/. A conventional solenoid with the same performance can draw as high as 17 watts of power. The savings in power usage over the installed life of the valve will lower the total cost of ownership up to 14%. ncreased performance The new technology accepts both A and voltages without sacrificing flow or pressure specifications. performance has been increased by 150% to 500% from today s industry standards, making the valves characteristics equivalent to A pressure and flow values. This simplifies your control by eliminating the need for A output cards, reduces wiring costs, and provides safer working environments for users operating on. Redat Next eneration coils are offered in three voltage ranges covering most electrical requirements /A or, /A or, or 12-24/. ach coil has built-in electrical surge suppression that protects the coil from external voltage spikes and eliminates inductive voltage spikes associated with conventional solenoids. An optional solenoid is available for use in lass, ivision 2 hazardous locations. Rugged esign ASO Redat Next eneration addresses many other operating characteristics that will further improve the life of your solenoid valves. These include a much lower temperature rise, and an increase in valve ambient temperature rating to 140 /60. ecause of our confidence in the rugged design of the Redat Next eneration solenoids, ASO is pleased to extend a 3-year warranty on the coils. Visit us online at to see our comprehensive product portfolio.

3 4 1/2 inch female conduit Polyester coated aluminum conduit hub nclosure Types 1 through 4X Now standard with 24 inch leads Stainless steel nameplate Steel clip with epoxy powder coated paint LP overmolded coil Optional lass, ivision 2 coil available for hazardous locations

4 VALV SLTON & ORRN As you use this catalog to select Redat Next eneration products, note these key operating features: ncrease in pressure ratings to A levels on all products (up to a 500% improvement) Lower power operation Voltage ranging uilt in surge suppression limination of A hum ncrease in A and operating temperatures Low solenoid temperature rise Longer coil life due to lower operating temperatures and electrical surge suppression Solenoid approvals to UL, SA, and standards RoS 2 ompliant ow to order ind the valve that you are looking for in the provided specifications tables. The tables contain the following information designed to help you in making your selection: Operating Pressure ifferential (psi) Pipe Orifice Max. Agency Agency Wattage Approx. Size ia. v low Min. Air-nert as Water Light 300 SSU Max luid Temp. rass onst. Ref. UL Stainless Steel onst. Ref. UL A/ Shipping Weight (lbs.) 1/2 5/ P094 4 m When ordering a valve product, specify the ASO base catalog number (x. 8210P094). This number will always be 8 digits long. hoose one of the three operating voltage ranges ( V/50-60z/, V/50-60z/ or 12-24/) and add it to the base catalog number (x. 8210P V/50-60z/). f you want to enhance the product with one or more of the options allowed in the Optional eatures hart for that catalog number, please add the appropriate prefix or suffix (as shown): Pipe Size Orifice ia. Solenoid Options ase atalog Number Resilient Materials Other Standard Rebuild Kit lass, ivision 2 oil Optional lass, ivision 2 solenoid (x. 8210P V/50-60z/) f an KM elastomer and manual operator are required, add VMO to the back of the base catalog number. (x. 8210P094VMO V/50-60z/) When ordering a rebuild kit for a valve, supply the rebuild kit number as shown in the table. (x ) When ordering a rebuild kit for a valve with a suffix, add the suffix to the appropriate standard rebuild kit. (x. The rebuild kit for the above valve with KM is V) All constructions are available with prefix for lass, ivision 2 requirements. When ordering a replacement coil, select from the following: rass Stainless Steel NR KM 1/2 5/8 8210P094 - l V J N - - V MO M Solenoid nclosures Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X. Optional: lass, ivision 2 for azardous Locations and Watertight, Types 3, 3S, 4, 4X. (To order, add prefix to catalog number.) Voltage Range Valve Prefix Replacement oil Part Number V/50-60z/ * V/50-60z/ * 12-24/ * V/50-60z/ * V/50-60z/ * 12-24/ * Warning: mproper selection or use of products and related items in this catalog can cause death, serious injury or property damage. f you need any assistance in selecting, specifying, or ordering a valve, please contact ASO at (800) PM R Oxygen Service PT Urethane Vacuum Manual Operator Mounting racket rass Stainless Steel

5 4 NXT NRATON ONTNTS 2-Way Valves 2-Way Normally losed Way Normally Open Way imensional rawings Way Valves 3-Way Normally losed Way Normally Open Way Universal Way imensional rawings Way Valves 9 imensional rawings 10 ngineering nformation 12-18

6 2-WAY Solenoid Valves 4 Two-way (2/2) Next eneration solenoid valves have one inlet port and one outlet port. ontrol of air, water, light oil, and non-corrosive media. Normally closed (opens when energized) and normally open (closed when energized) operation. Pipe sizes 1/8 to 2 inch. 1 Specifications Operating Pressure ifferential (psi) Pipe Orifice Max. Max Agency Agency Wattage Size ia. v low Min. Air-nert as Water Light 300 SSU luid Temp. rass onst. Ref. UL Stainless Steel onst. Ref. UL A/ eneral Service - Normally losed 1/8 3/ R175 ƒ 1 l 1/8 3/ R099 ƒ 1 l /8 3/ R277 1 m 8262R178 1 m 1/8 1/ R105 1 m 8262R174 1 m 1/8 1/ R077 1 m /4 3/ R107 ƒ 2 l /4 3/ R181 ƒ 2 l 1/4 3/ R109 2 m 8262R183 2 m 1/4 1/ R232 2 m 8262R185 2 m 1/4 5/ R202 2 m 8262R220 2 m 1/4 7/ R208 2 m 8262R226 2 m 1/4 9/ R212 2 m 8262R230 2 m 1/4 9/ R078 2 m /4 5/ P /8 1/ R115 3 m 8263R191 3 m 3/8 5/ R200 3 m 8263R193 3 m 3/8 7/ R124 3 m 8263R332 3 m 3/8 9/ R210 3 m 8263R333 3 m 3/8 5/ P /8 5/ P093 4 m /8 5/ P006 4 l /2 3/ P P /2 5/ P094 4 m /2 5/ P087 7 l 1/2 5/ P007 4 m /4 5/ P088 7 l 3/4 3/ P095 7 m /4 3/ P003 8 m /4 3/ P P m /4 1 1/ P m /2 1 1/ P m / P l eneral Service - Normally Open 1/8 3/ R155 ƒ 1 l 8262R168 ƒ 1 l 1/8 3/ R156 1 l 8262R169 1 l 1/8 3/ R128 1 l 8262R236 1 l 1/8 1/ R129 1 l 8262R237 1 l 1/4 3/ R161 ƒ 2 l 8262R199 ƒ 2 l 1/4 3/ R260 2 l 8262R130 2 l 1/4 3/ R261 2 l 8262R134 2 l 1/4 1/ R262 2 l 8262R138 2 l 1/4 5/ R263 2 l 8262R142 2 l 1/4 7/ R264 2 l 8262R148 2 l 1/4 9/ R265 2 l 8262R152 2 l 3/8 1/ R070 3 l 8263R080 3 l 3/8 5/ R071 3 l 8263R081 3 l 3/8 7/ R072 3 l 8263R082 3 l 3/8 9/ R073 3 l 8263R083 3 l 3/8 5/ P l /2 5/ P l /4 3/ P l /4 3/ P l m = Safety Shut-off Valve. l = eneral Purpose Valve

7 4 2-WAY Solenoid Valves Pipe Size Orifice ia. ase atalog Number Resilient Materials and Suffix Options Other Standard Rebuild Kit rass Stainless Steel Ammonia Optional eatures hart Silicone ree ry Air NR LT NR KM 1/8 3/ R099 ƒ 8262R175 ƒ - S l - - M W W 1/8 3/ R155 ƒ 8262R168 ƒ - S l - - M W W 1/8 3/ R R169 N S - l A V J N T - - MS M /8 3/ R R178 N S - l A V J N T - MS M /8 3/ R R236 N S - l A V J N T - - MS M /8 1/8 8262R R174 N S - l A V J N T - V MS M /8 1/8 8262R S - - l M /8 1/8 8262R R237 N S - l A V J N T - V MS M /4 3/ R107 ƒ 8262R181 ƒ l - - M W W 1/4 3/ R161 ƒ 8262R199 ƒ - S l - - M W W 1/4 3/ R R130 N S - l A V J N T - - MS M /4 3/ R R183 N S P l A V J N T - - MS M /4 3/ R R134 N S - l A V J N T - - MS M /4 1/8 8262R R184 N S P l A V J N T - - MS M /4 1/8 8262R R138 N S - l A V J N T - - MS M /4 5/ R R220 N S P l A V J N T - - MS M /4 5/ R R142 N S - l A V J N T - - MS M /4 7/ R R226 N S P l A V J N T - - MS M /4 7/ R R148 N S - l A V J N T - - MS M /4 9/ R R230 N S P l A V J N T - V MS M /4 9/ R R152 N S - l A V J N T - V MS M /4 9/ R S - - l M /4 5/ P l A /8 1/8 8263R R191 N S - l A V J N T - - MS M /8 1/8 8263R R080 N S - l A V J N T - - MS M /8 5/ R R193 N S - l A V J N T - - MS M /8 5/ R R081 N S - l A V J N T - - MS M /8 7/ R R332 N S - l A V J N T - - MS M /8 7/ R R082 N S - l A V J N T - - MS M /8 9/ R R333 N S - l A V J N T - - MS M /8 9/ R R083 N S - l A V J N T - - MS M /8 5/ P l /8 5/8 8210P l - V J N - - V MO M /8 5/8 8210P l - V J N - - V - M /8 5/8 8210P l - V J N MO M /2 3/8 8223P P l /2 5/8 8210P l - V J N - - V MO M /2 5/8 8210P l - V J N - - V - M /2 5/8-8210P l - V J N MO M /2 5/8 8210P l - V J N MO M /4 5/8-8210P l - V J N MO M /4 3/4 8210P l - V J N - - V MO M /4 3/4 8030P l - V J N MO M /4 3/4 8210P l - V J N - - V - M /4 3/4 8030P l - V J N M /4 3/4 8223P l P l - V J N MO /4 1 1/8 8210P l - V J N MO /2 1 1/4 8210P l - V J N MO /4 8210P l - V J N MO l = Standard. Other options may be available. All option combinations may not be available. Please consult your local ASO contact. Valve contains PT main disc; Pressure rating reduced by 25%; Pressure rating limited to 250 psi; Valve contains Nylon 11 piston. ƒ ast UR disc supplied as standard, limits min. ambient temp. to 32 (0 ). uel gas service only; Ambient Temp. -40 to 140, luid Temp. -40 to 167 ; as capacity for 8262R077 is 18,700 tu/hr, for 8262R078 53,500 tu/hr based on 1" W.. 2" W.. nlet Pressure, 1000 tu/cu.ft. or more, 0.64 Specific ravity as. N suffix only available for Stainless Steel constructions V V A/, V A/. PM R Oxygen Service PT Urethane Vacuum Manual Operator Mounting racket rass Stainless Steel 2

8 2-WAY Solenoid Valves 4 imensions: inches onst. Ref [8].7 [17.5] MOUNTN OLS onst. Ref. 1 ANPT OT NS.6 [15] MOUNTN OLS LOW M5 TRA.25 [6.4] MN. ULL TRA PT. 2 OLS OR MOUNTN. onst. Ref. 2 onst. Ref. 3 ANPT OT NS ANPT OT NS.34 [9].87 [22.2] MOUNTN OLS.57 [14].75 [19] MOUNTN OLS.87 [22.2] MOUNTN OLS.81 [20.6] MOUNTN OLS LOW M5 TRA.30 [7.6] MN. ULL TRA PT. 2 OLS OR MOUNTN. LOW M5 TRA.24 [6] MN. ULL TRA PT. 2 OLS OR MOUNTN onst. Ref. 4, 7, 15, 16, 17 onst. Ref. 5, 6, 9 3

9 4 2-WAY Solenoid Valves imensions: inches onst. Ref. 8 onst. Ref. 10 onst. Ref. 11, 12 onst. Ref. 18 4

10 3-WAY Solenoid Valves 4 Three-way (3/2) Next eneration solenoid valves have three ports and two orifices. When one orifice is open, the other is closed. ontrol of air, water, light oil, and other non-corrosive media. Normally closed (pressure to cylinder port when energized) operation. Normally open (cylinder port exhausts when energized) operation. Universal operation (can function as normally open, normally closed, diverter of fluid flow, or selector of 2 fluid sources configurable by piping). Pipe sizes 1/4 to 3/4 inch. 5 Specifications Pipe Size Orifice ia. Operating Pressure ifferential (psi) Max. Air-nert as Water Max. Agency Agency Wattage Approx. Light 300 SSU luid Temp. rass onst. Ref. UL Stainless Steel onst. Ref. UL A/ Shipping Weight (lbs.) v low Min. eneral Service - Normally losed 1/8 3/ R031 1 l 8314R037 1 l 1.7 1/8 3/ R032 1 l 8314R038 1 l 1.7 1/8 1/ R033 1 l 8314R039 1 l 1.7 1/4 3/ R034 2 l 8314R068 2 l 1.8 1/4 3/ R035 2 l 8314R121 2 l 1.8 1/4 1/ R036 2 l 8314R126 2 l 1.8 1/4 5/ R130 2 l 8314R230 2 l 1.8 1/4 7/ R131 2 l 8314R231 2 l 1.8 1/4 9/ R132 2 l 8314R232 2 l /4 5/ P182 3 l /4 7/ P184 3 l /4 5/ P186 3 l /4 3/ ƒ P035 4 l /4 9/ P001 5 l /8 9/ P002 5 l /8 5/ P054 6 l /2 5/ P064 6 l /4 11/ P074 7 l NAMUR Mount - 3/2 Normally losed 1/4 3/ P704 9 l 8320P714 9 l eneral Service - Normally Open 1/8 3/ R049 1 l 8314R055 1 l 1.7 1/8 3/ R050 1 l 8314R056 1 l 1.7 1/8 1/ R051 1 l 8314R057 1 l 1.7 1/4 3/ R052 2 l 8314R069 2 l 1.8 1/4 3/ R053 2 l 8314R122 2 l 1.8 1/4 1/ R054 2 l 8314R070 2 l /4 5/ R133 2 l 8314R233 2 l 1.8 1/4 7/ R134 2 l 8314R234 2 l 1.8 1/4 9/ R135 2 l 8314R235 2 l 1.8 1/8 3/ P136 8 l 8320P146 8 l 2.5 1/4 1/ P190 3 l /4 5/ P192 3 l /4 7/ P194 3 l eneral Service - Universal Operation 1/8 3/ R041 1 l 8314R042 1 l 1.7 1/8 3/ R043 1 l 8314R044 1 l 1.7 1/8 1/ R045 1 l 8314R040 1 l 1.7 1/4 3/ R006 2 l 8314R123 2 l 1.8 1/4 3/ R007 2 l 8314R120 2 l 1.8 1/4 1/ R008 2 l 8314R124 2 l /4 5/ R127 2 l 8314R227 2 l 1.8 1/4 7/ R128 2 l 8314R228 2 l 1.8 1/4 9/ R129 2 l 8314R229 2 l 1.8 1/4 5/ P172 3 l /4 7/ P174 3 l /4 5/ P176 3 l l = eneral Purpose Valve. 1/4" exhaust orifice with 0.73 v flow; 11/32" exhaust orifice with 1.20 v flow; 3/64" exhaust orifice with 0.06 v flow. 3/32" exhaust orifice with 0.20 v flow. ƒ 10 psi minimum for light oils. Max. fluid temp. 180 for light 45 SSU. Pressure rating for light 45 SSU V V A/, V A/.

11 4 3-WAY Solenoid Valves Optional eatures hart ase atalog Number Resilient Materials and Suffix Options Other Standard Rebuild Kit Pipe Size Orifice ia. rass Stainless Steel Silicone ree NR KM PM 1/8 3/ R R037 S l V - - N MS M /8 3/ R R042 S l V - - N MS M /8 3/ R R055 S l V - - N MS M /8 3/ R R038 S l V - - N MS M /8 3/ R R044 S l V - - N MS M /8 3/ R R056 S l V - - N MS M /8 1/8 8314R R039 S l V - - N MS M /8 1/8 8314R R040 S l V - - N MS M /8 1/8 8314R R057 S l V - - N MS M /8 7/ P P146 ƒ l V J N T - - MO/MS M /4 1/ P190 - ƒ l V J N T - - MO/MS M /4 3/ R R123 S l V - - N MS M /4 3/ R R068 S l V - - N MS M /4 3/ R R069 S l V - - N MS M /4 5/ P172 - ƒ l V J N T - - MO/MS M /4 5/ P182 - ƒ l V J N T - - MO/MS M /4 5/ P192 - ƒ l V J N T - - MO/MS M /4 3/ R R120 S l V - - N MS M /4 3/ R R121 S l V - - N MS M /4 3/ R R122 S l V - - N MS M /4 3/ P035 - ƒ l V - - N /4 3/ P P714 ƒ l V J N T - - MO/MS /4 7/ P174 - ƒ l V J N T - - MO/MS M /4 7/ P184 - ƒ l V J N T - - MO/MS M /4 7/ P194 - ƒ l V J N T - - MO/MS M /4 1/8 8314R R124 S l V - - N MS M /4 1/8 8314R R126 S l V - - N MS M /4 1/8 8314R R070 S l V - - N MS M /4 5/ R R227 S l V - - N MS M /4 5/ R R230 S l V - - N MS M /4 5/ R R233 S l V - - N MS M /4 5/ P176 - ƒ l V J N T - - MO/MS M /4 5/ P186 - ƒ l V J N T - - MO/MS M /4 7/ R R228 S l V - - N MS M /4 7/ R R231 S l V - - N MS M /4 7/ R R234 S l V - - N MS M /4 9/ R R229 S l V - - N MS M /4 9/ R R232 S l V - - N MS M /4 9/ R R235 S l V - - N MS M /4 9/ P001 - ƒ l V MO/MS /8 9/ P002 - ƒ l V MO/MS /8 5/8 8316P054 - ƒ l V J N MO M /2 5/8 8316P064 - ƒ l V J N MO M /4 11/ P074 - ƒ l V J N MO M l = Standard. Other options may be available. All option combinations may not be available. Please consult your local ASO contact. Pressure rating reduced by 25%. Upper disc is KM. Not available with PT resilient materials. Pressure rating limited to 100 psi (6.9 bar) for MO constructions. ƒ onsult factory. R Oxygen Service PT Urethane 6 Vacuum Manual Operator Mounting racket rass Stainless Steel

12 3-WAY Solenoid Valves 4 imensions: inches onst. Ref. J onst. Ref.1, 2 1/8 PP TRA 3 ONUT 1/2" NPT 1/4 PP TRA (2 PLAS) MOUNTN MNSONS (1/8 PP SZ) MOUNTN MNSONS (1/4 PP SZ).30 [7.6].59 [15] M5 TRA.29 [7] MN.ULL TRA PT 2 OLS OR MOUNTN.34 [9].87 [22] M5 TRA.29 [7] MN.ULL TRA PT 2 OLS OR MOUNTN.69 [18].87 [22] LOW LOW onst. Ref. 3 onst. Ref. 4 2 MOUNTN OLS.31 [7.8] P OR.164 [4.1] TRA UTTN SRW J 1.50 [38].75 [19] 7

13 4 3-WAY Solenoid Valves imensions: inches onst. Ref. 5 onst. Ref UN [11.1] P 2 PLAS J onst. Ref. 7 onst. Ref /8 PP TRA 3 PLAS Ø.28 OL OR MOUNTN, 2 PLAS onst. Ref OR M5 SRWS, 2 PLAS.28 OR UN-2A & UN-2A SRWS, 2 PLAS /4 ANPT /4 ANPT 3 Ø.22 x.125 P OR POSTONN OWL 8

14 4-WAY Solenoid Valves 4 our-way, four port (4/2) and five port (5/2) Next eneration solenoid valves have one pressure port, 2 cylinder ports, and either 1 or 2 exhaust ports. ontrol of air, water, light oil, and non-corrosive media. Single solenoid operation (pressure and exhaust ports and cylinder ports alternate connection based on solenoid operation). Pipe sizes 1/4 to 1 inch. Specifications v low Operating Pressure ifferential (psi) Pipe Orifice Max. Max. Agency 316L Agency Wattage Size ia. Pressure xhaust Min. Air-nert as Water Light 300 SSU luid Temp. rass onst. Ref. UL Stainless Steel onst. Ref. UL A/ eneral Service - Single Solenoid 1/4 1/ P001 1 l /4 1/ P070 2 l /8 3/ P072 3 l /2 3/ P074 3 l /4 3/ P076 4 l / P078 4 l eneral Service - 4/2 ual Solenoid 3/8 3/ P080 5 l ƒ 1.5 NAMUR Mount - 3/2, 5/2 Single Solenoid 1/4 1/ P401 6 l 8551P409 6 l 1.0 ƒ 1.5 l = eneral Purpose Valve. 25 psi minimum for light oils. 3/32" exhaust orifice. Viscosity 50 SSU max. Aluminum body. ƒ 12-24V V A/, V A/. 1.0 ƒ 1.5 Optional eatures hart Pipe Size Orifice ia. ase atalog Number Resilient Materials and Suffix Options Other Standard Rebuild Kit rass 316L Stainless Steel NR KM PM 1/4 1/ P001 - l V MO /4 1/4 8551P401* 8551P409 l M/MS - - 1/4 1/4 8344P070 - l V MO /4 3/4 8344P080 - l V MO /8 3/8 8344P072 - l V MO /2 3/8 8344P074 - l V MO /4 3/4 8344P076 - l V MO /4 8344P078 - l V MO l = Standard. * Aluminum body. mportant A Minimum Operating Pressure ifferential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASO flow controls and other similar components must be installed in the cylinder lines only. R Oxygen Service PT Urethane Vacuum Manual Operator Mounting racket rass 9

15 4 4-WAY Solenoid Valves imensions: inches onst. xhaust Ref. J K Pipe Size / / / onst. Ref. 1 J onst. Ref. 2 K J onst. Ref. 3, 4 K J 10

16 4-WAY Solenoid Valves 4 imensions: inches onst. Ref SOL 2.13 SOL A 1.56 P PP TRA 3 PLAS Ø.34 2 OLS OR MOUNTN A P /2 PP TRA 3.09 onst. Ref. 6 Series 8551 NPT 1/4 L W Add Suffix MO M Optional Manual Operators 2 2 escription Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W NAMUR ootprint 3 1 1/8 NPT AUX. PRSSUR PORT L1 M 0 2 Momentary push in by hand MS Push and turn to lock by hand (32).95 (24) 11

17 4 NNRN ngineering Section Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core. A valve body containing one or more orifices. low through an orifice is controlled by the movement of the core when the solenoid is energized or de-energized. The core is enclosed in a sealed tube, providing a compact, leaktight assembly. or additional information on different types and functions of solenoid valves including direct acting, internally pilot operated valves, two-way, three-way, and four-way valves please visit our website at Solenoids All Redat Next eneration solenoid valves are rated for continuous duty under the operating conditions outlined within this section. oil Operating Voltage Ranges All coils are designed for industrial operating voltages and can be used on the following voltage ranges: Voltage Range Minimum Voltage Maximum Voltage V/50 or 60z/ V/50 or 60z/ / only oil ore Magnet wire - lass insulation ody Overmold LP The coils with voltage ranges of and have three lead wires, 24 inches long (2 red for power input, and one green lead for grounding where necessary). These two versions are not polarity sensitive. The coil with a voltage range of 12-24/ has 3 lead wires, one red, one black, and one green. This coil is polarity sensitive. The red lead is the positive, black is the negative, and green is the ground wire. This solenoid is also polarity protected. Reversing the polarity will not damage the coil, but the coil will not function until the correct polarity is applied. Note: The and voltage range is also suitable for battery charging circuits designed around a 125/ nominal voltage range. Lead wire - UL and SA listed 600 volt leads, 6 strand, 18awg, P coated obbin-lp 12

18 NNRN 4 lectrical Specifications 2 Watt lectronic oils Type Maximum Ambient Temperature Maximum ycle Rate Standard oil lass of nsulation Operation/ Second Power onsumption The Next eneration solenoid nominal power rating is 1.0 watt of power for 12-24V and 1.5 watts for V A/, and V A/. The advanced technology used in the Next eneration coil includes electronic circuitry which may limit the compatibility with certain control system components. The following issues need to be considered when specifying an output card or device to operate the Next eneration coil. An initial inrush current spike is drawn by the Next eneration coil. This inrush spike is 72 msec in duration, which is sufficient time for the core to reach the plugnut. The electrical requirement then drops to the holding value. nrush urrent: The power source, wiring, and output device used need to have surge ratings equal to or greater than the inrush current value (appropriate to the voltage range) specified in the table below. nrush urrent Rating oil Version Peak nrush urrent (Amps) 12-24/ /50-60z/ /50-60z/ 0.32 Maximum uration = 72 ms olding urrent: The power source, wiring, and output device used need to have continuous current ratings equal to or greater than the holding current value (appropriate to the voltage range) specified in the table below. olding urrent Rating oil Version 12-24/ /50-60z/ /50-60z/ nput Voltage Average olding urrent (Amps) Average olding Volt-Amps (VA) Supervisory/Leakage urrents: The leakage current is defined as a current that is supplied from an output device when the device is in its off or de-activated state. The Next eneration coil is suitable for systems using supervisory currents that do not exceed the drop-out currents noted in the table below. Supervisory/Leakage urrent Rating oil Version rop-out urrent (ma) 12-24/ /50-60z/ /50-60z/ 7 mportant: Supervisory and leakage currents above the drop-out current listed with cause improper operation. onsult your local ASO Sales office for additional assistance. 13

19 4 NNRN Solenoid nclosures The Next eneration solenoid coil is fully encapsulated using upont Zenite Liquid rystal Polymer resin (LP). Zenite (LP) is a thermoplastic polyester resin which exhibits several advantages over other thermoplastics. The advantages include excellent resistance to a wide range of organic solvents and automotive fluids*, resistance to impact, and long term retention of properties at continuous-use temperatures. *hemical resistance of Zenite LP may not be suitable for all applications. Zenite LP is not suitable for caustic solution. Please consult ASO for appropriate product solutions. Zenite is a registered Trademarks of.. du Pont de Nemours and ompany. eneral Purpose/Watertight ntended for indoor and outdoor use and provides protection classifications from NMA types 1 through 4X. Type 1 eneral Purpose ntended for indoor use, primarily to provide protection for enclosed parts in locations without unusual service conditions. N-type terminals meeting SO 4400 and N Standard Type 2 ripproof ntended for indoor use, primarily to provide protection against limited amounts of falling water or dirt. Type 3 Raintight, usttight, and Sleet (ce) Resistant ntended for outdoor use, primarily to provide protection against wind-blown dust, rain, and sleet; undamaged by the formation of ice on the enclosure. Type 3S Raintight, usttight, and Sleet (ce) Resistant ntended for outdoor use, primarily to provide protection against wind-blown dust, rain, and sleet; external mechanism remains operable when ice laden. Type 3R Rainproof, Sleet (ce) Resistant ntended for outdoor use, primarily to provide protection against falling rain and sleet; undamaged by the formation of ice on the enclosure. Type 4 Watertight and usttight ntended for indoor or outdoor use to provide protection against splashing water, water seepage, falling or hose-directed water, and severe external condensation; undamaged by the formation of ice on the enclosure. Type 4X Watertight, usttight, and orrosion Resistant Same as Type 4 but provides additional protection to resist corrosion. lass, ivision 2 for azardous Locations/Watertight Meets Types 1 through 4X and is UL listed and SA certified for lass, ivision 2, roups A,,, and and lass, ivision 2, roups and. Operating temperature code T4A (120 ). 14

20 NNRN 4 Valve Specifications Minimum Operating Pressure ifferential The minimum operating pressure differential is required to fully open the valve and keep it open. or 2-way valves with a floating diaphragm, the valve may start to close below the minimum pressure differential. or 3 and 4-way valves, the minimum operating pressure differential is measured between the pressure and exhaust ports and must be maintained through the operating cycle to ensure complete transfer from one position to the other. Note: ung diaphragm constructions do not require a minimum pressure differential, however, may not yield maximum flow rates at low-pressure differentials. Maximum Operating Pressure ifferential (MOP) The maximum operating pressure differential refers to the maximum difference in pressure between the inlet and outlet ports, against which the solenoid can safely operate the valve. f the pressure at the outlet is not known, it is safest to regard the supply pressure as the MOP. Minimum Ambient Temperature The nominal limitation of 32 (0 ) is advisable for any valve that might contain moisture (water vapor). Where freezing water is not a factor, the minimum ambient temperature of the products listed in this catalog is 14 ( -10 ). or 8262/8263/8314 Series, the minimum ambient temperature is -13 (-25 ). Special constructions are available with low temperature elastomers to provide service at -40 (-40 ) ambient temperatures. onsult ASO for more information. Maximum Ambient Temperature The maximum ambient temperature is 140 (60 ). This limit is based on continuous energization with the maximum fluid temperatures as shown on each catalog page. Response Time Response time from fully closed to fully open or vice versa depends on valve size, operating mode, fluids, temperature, inlet pressure, and pressure drop. The response times for Next eneration are defined as: - Small direct acting valves 10 to 60 msec - Large direct acting valves 25 to 90 msec nternally pilot operated valves: - Small diaphragm types 20 to 100 msec - Large diaphragm types 80 to 150 msec - Small piston types 80 to 150 msec - Large piston types 105 to 200 msec Operation on liquids has relatively little effect on small direct acting valves, however, response times of large direct acting and internally piloted valves may be lengthened by 50% to 100%. Viscosity All valves with a pressure rating for light oil are designed for use with oils rated for a maximum of 300 SSU's with the following exceptions: - Series 8314, 8317, SSU - Series SSU 15

21 4 NNRN Manual Operators Manual operators are provided to operate the valves manually when electric actuation is not provided. There are two basic types of manual operators, momentary and maintained. To determine which type of manual operator is available for your valves, please see the Optional eatures hart on the relevant valve catalog page. Once it is determined that the subject valve can accommodate a manual operator, the chart below will tell you the type of manual operator. The chart also references the relevant cutaway illustration. Series Number onst. Ref. Manual Operator Suffix Manual Operator Type llustration Number MO Maintained , 7, 10, 11, 12 MO Maintained MS Maintained MS Maintained MS Maintained , 6 MO Maintained MO Momentary MS Maintained MO Momentary MS Maintained , 3, 4 MO Maintained MO Maintained 5 utaway llustrations Resilient Material Selection Acetal (POM) A high performance engineered plastic with good fatigue life, low moisture sensitivity, and high resistance to solvents and chemicals. PM (thylene Propylene) PM is selected for applications above the NR temperature range, such as handling hot water and steam. thylene propylene has an extremely wide range of fluid compatibility, but has the distinct disadvantage that it cannot be used with petroleum-based fluids or contaminated fluids (such as lubricated air). t has a useful temperature range of -10 to 300 (-23 to 149 ). KM KM is a fluorocarbon elastomer primarily developed for handling such hydrocarbons as jet fuels, gasolines, solvents, etc., which normally cause detrimental swelling to NR. KM has a high temperature range similar to PM, but more resistant to dry heat. KM has a wide range of chemical compatibility. t has a useful temperature range of 0 to 350 (-18 to 177 ). R (hloroprene, Neoprene) R is principally used as an external seal in refrigeration applications. t is also utilized for oxygen service. t has a useful temperature range of 0 to 180 (-18 to 82 ). NR (una "N", Nitrile) NR is commonly referred to as a nitrile rubber and is the standard synthetic elastomer for accomplishing resilient-type seating or sealing in ASO valves. t has excellent compatibility for most air, water, and light oil applications. t has a useful temperature range of 0 to 180 (-18 to 82 ). Oxygen Service All valve parts are degreased and blacklight inspected for cleanliness. They are assembled and tested in a clean area using oil-free air or nitrogen; helium mass spectrometer tested for external leakage. The pipe connections are sealed with plugs, and each valve is tagged certifying testing. All valves are shipped in sealed bags. PT PT and PT with fillers are considered more a plastic than a resilient-type material. They are virtually unattacked by any fluid. Their temperature usage has ranges from discs for cryogenic valves to discs for steam valves. They are not easily fabricated and are known to have cold flow characteristics which may contribute to objectionable leakage, particularly on gases. Urethane Urethane is primarily used on high pressure valves, and/or for long life applications, because of its high strength and abrasion resistance. The physical and chemical properties of urethane vary depending on whether the compound is polyester or polyether based. Urethane has a wide range of chemical resistance including alcohols, non-aromatic compounds, ethers, edible fats and oils, hydraulic fluid, and water. t has a useful temperature range of -90º to 200º for ethers, and -30º to 200º for esters. Polyester based Urethanes in contact with moisture should be limited to a maximum temperature of 140º. 16

22 NNRN 4 Valve Parts in ontact with luids Series ody Seals and iscs isc older ore uide Springs Shading oil 8030 rass NR Stainless Steel opper Stainless Steel NR Stainless Steel Silver rass NR Stainless Steel opper ( 750 psi) 8262 (> 750 psi) 8262 ( 750 psi) 8262 (> 750 psi) 304 Stainless Steel PT, NR Stainless Steel Silver rass NR, PA, PT Stainless Steel opper 304 Stainless Steel NR Stainless Steel Silver 304 Stainless Steel UR Stainless Steel Silver rass NR Stainless Steel opper rass UR Stainless Steel opper 8262R077 rass LT NR - POM nconel opper 8262R078 rass LT NR - POM nconel opper Stainless Steel NR Stainless Steel Silver 8263 rass NR Stainless Steel opper Stainless Steel NR, KM - POM 302 Stainless Steel Silver 8314 rass NR, KM - POM 302 Stainless Steel opper 8316 rass NR POM POM 302, 17-7P Stainless Steels opper 8317 rass NR, KM, R - POM 302, 17-7P Stainless Steels opper Stainless Steel NR POM POM 302 Stainless Steel Silver 8320 rass NR POM POM 302 Stainless Steel opper 8321 rass NR POM POM 302 Stainless Steel opper 8344 rass NR POM POM 302, 17-7P Stainless Steels opper 8345 rass NR, PA - POM 302 Stainless Steel opper Stainless Steel NR, PA - POM 302 Stainless Steel opper 8551 Anodized Aluminum NR, PA - POM 302 Stainless Steel opper Note: All core tubes are 305 stainless steel and all cores and plugnuts are 430 stainless steel. 8210P033, 8210P034, and 8210P035 with PA isc older 17

23 4 NNRN Approvals Approval Listing ode and nformation UL, SA, and listings are indicated on each series of valves in this catalog. Listing codes and other information follow in this section. Agency Valve lassifications and ode Reference Solenoid Recognized omponents Solenoids in this category are intended for use as factory-installed components of equipment where final acceptability must be determined by UL or SA. ASO Redat Next eneration solenoids are listed in the UL recognized component index under uide No. YSY2 for ordinary locations and VAPT for hazardous locations. eneral Purpose Valves Normally open or normally closed valves intended to control the fluid flow, but not to be depended upon to act as safety valves. This is a UL and SA classification and is not intended to indicate valve service or application. eneral purpose valves are listed in UL index under uide No YOZ or YOZ2 for ordinary locations and YTSX or YTSX2 for hazardous locations. Safety Shutoff Valves Normally closed valves of the on and off type, intended to be actuated by a safety control or emergency device, to prevent unsafe fluid delivery. They may also be used as eneral Purpose valves. Multiple port valves may be designated as safety shutoff valves only with respect to the normally closed port. This is a UL and SA classification. Safety shutoff valves are listed in UL index under uide YOZ or YOZ2 for ordinary locations and YTSX or YTSX2 for hazardous locations. ^ Underwriters Laboratories (UL) UL429, lectrically Operated Valves. UL1604, lectrical quipment for use in lass and, ivision 2 and lass hazardous classified locations. % anadian Standards Association (SA) Standard 22.2 No. 139, lectrically Operated Valves. Standard 22.2 No. 213, lectrical equipment for use in lass, ivision 2 hazardous locations. ) uropean irective () The council of the uropean ommunities under the treaty establishing the uropean conomic ommunity () adopted into law a series of directives to harmonize technical standards. Solenoid valves may be controlled by: ouncil irective # M(lectromagnetic apability) 2004/108/7 Low Voltage 206/95/ P(Pressure quipment irective) 97/23/ ASO Redat Next eneration valves comply with these directives as applicable, through third party or self-certification. The eneral Purpose/Watertight coils each bear the approval mark on the coil. Quality Assurance ASO s Quality Assurance Program meets all the requirements of SO ASO can provide product from 17 SO-certified facilities around the world. 18

24 lobal ontacts Australia (61) razil (55) anada (1) hina (86) zech Republic (420) ubai - UA (971) rance (33) ermany (49) ndia (91) taly (39) Japan (81) Mexico (52) Netherlands (31) Singapore (65) South Korea (82) Spain (34) United Kingdom (44) ASO Valve, nc. Tel (1) info-valve@asco.com 10/13 V7381 R11

Agency Air-Inert Gas Water. Approx. Shipping Weight (lbs.) 1/2 5/ P Brass. Const.

Agency Air-Inert Gas Water. Approx. Shipping Weight (lbs.) 1/2 5/ P Brass. Const. NXT NRATON lectronically nhanced Solenoid Valves rass and odies 1/" - 2" NPT 2/2 3/2 /2 eatures ncrease in pressure ratings to A levels on all products (up to a 500% improvement) Lower power operation

More information

Agency Air-Inert Gas Water. Approx. Shipping Weight (lbs.) 1/2 5/ P Brass. Const.

Agency Air-Inert Gas Water. Approx. Shipping Weight (lbs.) 1/2 5/ P Brass. Const. NXT NRATON lectronically nhanced Solenoid Valves rass and Stainless Steel odies 1/" - 2" NPT 2/2 3/2 /2 SRS eneration eatures ncrease in pressure ratings to A levels on all products (up to a 500% improvement)

More information

4 N E X T G E N E R A T I O N

4 N E X T G E N E R A T I O N N X T G N R A T I O N lectronically nhanced Solenoid Valves and Stainless Steel Bodies /" - " NPT / 3/ / SRIS Next Generation Features Increase in DC pressure ratings to AC levels on all products (up to

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

2-Way/2 Position Valves

2-Way/2 Position Valves 4 2-Way/2 Position Valves Two-way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply Normally Closed (NC) Fluid is shut off when

More information

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c The 188 is a 3 Way, 10 mm wide micro solenoid valve designed to be used in fluid power applications. Using air or other neutral gasses the 188 can be used to pilot other valves or cylinders. ompact manifold

More information

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4 NPT. Features. Construction. Direct Acting Direct Mount Pilot Valves Brass or Stainless Steel Bodies /" NPT / 83 Direct Mount Features NAMUR direct mount version of the rugged, dependable 83 Series valves Direct acting, high flow

More information

3/2 ^ % Features. Construction. Electrical

3/2 ^ % Features. Construction. Electrical 4 Pilot Operated Spool Valves xplosionproof Solenoid Valves 316L odies 1/4" NPT 3/2 SRIS 364 eatures Ideal for oil and gas control panel applications rop-in replacement design - compatible with most existing

More information

Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies

Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies Constructions Suitable for - C to -5 C Ambient, 3 and Way Constructions Available Brass, Aluminum and Stainless Steel Bodies Air and Inert Gas Service INDEX General Service Valves -Way/ Position 8 Aluminum

More information

Constructions Suitable for -40 C to -50 C Ambient

Constructions Suitable for -40 C to -50 C Ambient Constructions Suitable for -40 C to -50 C Ambient 2, 3 and 4 Way Constructions Available Brass and Stainless Steel Bodies Air and Inert Gas Service AIR/INERT GAS QUALITY STATEMENT FOR LOW AMBIENT VALVES

More information

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8 to 2 1/2 NPT. Features. Construction. 4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide

More information

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft) . W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased

More information

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT ^ % )

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT ^ % ) 888-87-6711 Normally Closed or Normally Open ot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT Features ot water service to 210 psi differential @ 210 F; sevice to 125 psi differential

More information

3 Way/2 Position Valves

3 Way/2 Position Valves Way/ Position Valves Three way valves have three pipe connections and two orifices. When one orifice is open, the other is closed, and vice versa. They are commonly used to alternately apply pressure to

More information

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4 to 1 NPT. Features .4 W Solenoid Valves Brass or Stainless Steel Bodies /4" to " NPT 4/ Features Moulded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Designed for use in automation

More information

^ % 3/2 5/2 SERIES 362/562. Features. Construction. Nominal Ambient Temp. Ranges. Electrical

^ % 3/2 5/2 SERIES 362/562. Features. Construction. Nominal Ambient Temp. Ranges. Electrical Pilot Operated Stainless Steel Spool Valves xplosionproof Solenoid Valves 6 Stainless Steel odies /4" NPT / / SRIS 6/6 eatures Ideal for valve automation for the oil and gas market Reliable, robust design

More information

8290 Series. Angle Body Piston Valves. Introducing the all NEW 8290 Assembly Configurator

8290 Series. Angle Body Piston Valves. Introducing the all NEW 8290 Assembly Configurator 4 82 Series Angle ody Piston Valves Introducing the all NW 82 Assembly onfigurator road range of pressure operated valves for air, water, steam, and light slurries ronze & stainless steel constructions

More information

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT Air and Inert Gas Non-Incendive Field Wiring Valves Brass, Aluminum, or Stainless Steel Bodies /" to " NPT / 5/ 5/3 Features solenoid enclosures to provide corrosion resistance in harsh environments Designed

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical. qwer Normally Closed or Normally Open and Hot Water Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Handle the challenges of high-temperature fluids. PTFE and EPDM discs,

More information

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F 4.4 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased

More information

Control & Power, Inc

Control & Power, Inc Way/ 2 and 3 Position Four ported valves are generally used to operate double-acting cylinders or actuators. They have four or five pipe connections, commonly called ports: One pressure inlet. Two cylinder

More information

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT Normally Closed or Normally Open Hot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT 2/2 Features Handle the challenges of high-temperature fluids PTFE and EPDM discs, stainless steel

More information

2/2. Air or Water Pilot Operated Angle Body Multi-Purpose Valves. Bronze or 316L Stainless Steel Bodies 3/8" to 2 1/2" NPT.

2/2. Air or Water Pilot Operated Angle Body Multi-Purpose Valves. Bronze or 316L Stainless Steel Bodies 3/8 to 2 1/2 NPT. 4 Air or Water Pilot Operated Angle ody Multi-Purpose Valves ronze or 36L Stainless Steel odies 3/8" to 2 /2" NPT 2/2 SRIS 82 The 82 Series consists of 2-way direct acting valves available in normally

More information

KIP Solenoid Selection

KIP Solenoid Selection KIP Solenoid Selection Solenoid Selection 1/2" NPT onduit dapter Nut Housing Stop Orifice (Normally Open) Spring Loaded Top Seal oil Plunger Spring, Plunger, tn ottom Seal Guide ssembly Shading ing ( Only)

More information

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type 31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F 4.55 Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NT / 3/ 4/ 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 low wattage coil Standard ambient

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.55 Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NT / 3/ 4/ 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 low wattage coil Standard ambient

More information

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2.

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2. Series port direct acting solenoid valve : Open when energized, close when energized NRL PURPOS VLV SRIS iscrete valve irect acting poppet structure Port size : Rc/, Rc/, Rc/, Rc/ JIS symbol / (normally

More information

3/2 SRIS Important These solenoid valves are intended for use on clean dry air, inert gas, or sweet dry natural gas filtered to 40 micron or bet

3/2 SRIS Important These solenoid valves are intended for use on clean dry air, inert gas, or sweet dry natural gas filtered to 40 micron or bet 4 Pilot Operated Spool Valves xplosionproof Solenoid Valves 316L odies 1/4" NPT 3/2 SRIS 364 eatures Ideal for oil and gas control panel applications rop-in replacement design - compatible with most existing

More information

Single Solenoid External Pilot Normally Closed

Single Solenoid External Pilot Normally Closed atalog 000- Operating ressure Internal ilot Solenoid Valves 3/" & 3/" ody 0 to 0 SI (standard) -/" ody to 0 SI (00 SI option available) Series Valves ilot Supply Internal ilot Remote ilot Valve Operating

More information

SOLENOID VALVES pilot operated, high flow floating diaphragms 3/8 to 1

SOLENOID VALVES pilot operated, high flow floating diaphragms 3/8 to 1 SOLNOI VLVS pilot operated, high flow floating diaphragms 3/8 to 1 N 3/2 P Series NO 316 TURS rass bodied high flow valves with two floating diaphragms for larger single actuators The solenoid valves vent

More information

SOLENOID VALVES direct operated core disc 1/4

SOLENOID VALVES direct operated core disc 1/4 SOLNOI VLVS direct operated core disc 1/ U N NO 3 1 2 3/2 Series 32 TURS Three way solenoid valves with orifice and pipe connections in valve body Valves are designed to handle relatively high pressure

More information

2/2 ^ % ) Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

2/2 ^ % ) Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8 to 2 1/2 NPT. Features. Construction. 4 ilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" 8210 2-AY Features ide range of pressure ratings, sizes, and resilient materials provide long service life

More information

SOLENOID VALVES direct operated core disc 1/4

SOLENOID VALVES direct operated core disc 1/4 SOLNOI VLVS direct operated core disc U N NO 3 1 2 3/2 Series 32 TURS Three way solenoid valves with orifice and pipe connections in valve body Valves are designed to handle relatively high pressure 3way

More information

Proveedor Integral de Soluciones para la Industria. Desde1963

Proveedor Integral de Soluciones para la Industria. Desde1963 Proveedor Integral de Soluciones para la Industria Desde1963 4 Vías uso general ASCO cuenta con la más amplia gama de válvulas solenoides de usos generales, en 2, 3, 4, y 5 vías, para el manejo de fluidos

More information

Your Global Source for Today s Most Popular Solenoid Valves

Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International

More information

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4 to 3 NPT. 4 qwer High Flow Main Pulse Valves Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT NC 2/2 SERIES Features Specially designed for reverse jet-type dust collector systems. High flow Cv s to 140 for effective

More information

SOLENOID VALVES pilot operated, high flow, heavy duty single solenoid / dual solenoid 1/4 to 1

SOLENOID VALVES pilot operated, high flow, heavy duty single solenoid / dual solenoid 1/4 to 1 SONOI VVS pilot operated, high flow, heavy duty single solenoid / dual solenoid 1/4 to 1 TURS Rugged forged brass bodied solenoid valves (mono- or bistable function) designed to provide maximum flow Solenoid

More information

Air Actuated Ball Valves 3-Way T-Port Stainless Steel, Full Bore 1/4 to 2 NPT

Air Actuated Ball Valves 3-Way T-Port Stainless Steel, Full Bore 1/4 to 2 NPT ir ctuated all Valves 3-Way T-Port Stainless Steel, ull ore 1/4 to 2 SRIS eatures ull Port 3-way T flow path irect mount valve with standard ISO5211 mount 316 stainless steel body, ball and stem ctuators

More information

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2 POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2 NC 2/2 Series 353 X003GB2009/R8 EATURES The piston cartridge pulse valves are especially designed for

More information

Proveedor Integral de Soluciones para la Industria

Proveedor Integral de Soluciones para la Industria Desde96 Proveedor Integral de Soluciones para la Industria Vías uso general ASCO cuenta con la más amplia gama de válvulas solenoides de usos generales, en,, 4, y 5 vías, para el manejo de fluidos tales

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NAMUR style, 1/4 to 1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NAMUR style, 1/4 to 1/2 FTURS SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NMUR style, / to / SO/JOUOMTI solenoid valves satisfy all relevant irectives

More information

N Series. High Speed Inline Poppet Valves 2 & 3-Way. Section D

N Series. High Speed Inline Poppet Valves 2 & 3-Way. Section D Series igh Speed Inline Poppet Valves & 3-Way Section www.parker.com/pneu/n X Viking Z asic Valve unctions...0 Series asic eatures... ommon Part umbers...-3 Model umber Index...4- Technical Information

More information

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1 SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1 NC 2/2 Series 220 FEATURES Small compact d valves particularly designed for hot water and steam, compatible with the seal materials

More information

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them

More information

Air Actuated 3-Way Ball Valves L-Port Brass, Standard Port 1/4 to 3 NPT

Air Actuated 3-Way Ball Valves L-Port Brass, Standard Port 1/4 to 3 NPT ir ctuated 3-Way all Valves -Port rass, Standard Port 1/4 to 3 SERIES eatures Spring Return or ouble cting Standard Port 3-way flow path irect mount brass valve using standard ISO5211 ctuators designed

More information

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NT / 3/ / 5/ 5/3 Features Available in different coil terminations H Class coil construction Designed

More information

Air Actuated Stainless Ball Valves 2-Piece Stainless Steel, Full Port 1/4 to 2 NPT

Air Actuated Stainless Ball Valves 2-Piece Stainless Steel, Full Port 1/4 to 2 NPT ir ctuated Stainless all Valves 2-Piece Stainless Steel, ull Port 1/4 to 2 SRIS eatures Spring Return or ouble cting ctuators ull Port direct mount ISO5211 valve 316 stainless steel body, ball and stem

More information

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband P-SERIES Temperature Switches Switches for -30 through 5 F with Adjustable Set Points and Fixed or Adjustable Features: Set point repeatability, + F (/2 C). All wiring terminals, adjustments and visual

More information

SOLENOID VALVES pressure assisted, zero minimum, high flow floating diaphragms 1/4 to 1/2

SOLENOID VALVES pressure assisted, zero minimum, high flow floating diaphragms 1/4 to 1/2 SONOI VVS pressure assisted, zero minimum, high flow floating diaphragms 1/ to 1/2 N UX Internal ilot xternal ilot 3/2 Series 316 TURS rass and stainless steel bodied high flow pilot valves with two spring

More information

Vic -300 Butterfly Valves

Vic -300 Butterfly Valves R IPS RON STL PIP ROOV VLVS 08.0 Vic -300 utterfly Valves PROUT SRIPTION ear Operator 3" with Position andle Vic -300 butterfly valves are designed for pressures ranging from vacuum to 300 PSI (065 kpa).

More information

FEATURES PORT ARRANGEMENTS

FEATURES PORT ARRANGEMENTS PTP Series PV 3-way all Valve Valve Pressure / Temperature 250 PTP Series valves can be used for flow diverting, mixing, or on/off isolation. They replace a Tee + 2 valve linkage assembly at reduced cost

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

SOLENOID VALVES pressure assisted, zero minimum, high flow floating diaphragms 1/4 to 1/2

SOLENOID VALVES pressure assisted, zero minimum, high flow floating diaphragms 1/4 to 1/2 SONOI VVS pressure assisted, zero minimum, high flow floating diaphragms 1/ to 1/2 N UX Internal ilot xternal ilot 3/2 Series 316 TURS rass and stainless steel bodied high flow pilot valves with two spring

More information

Series 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF

Series 1, 2 & 6 Options selector. Port 4 = 1/8 NPT 5 = 1/4 NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF KIP Isolation Valves Ideal for control of corrosive and aggressive media Elastomer diaphragm provides protection from aggressive, corrosive, and gritty media Isolation valves can be equipped with a low

More information

Valve functions Operating mechanism Valve sizing Electrical parameters Manual overrides

Valve functions Operating mechanism Valve sizing Electrical parameters Manual overrides Valve functions.................... 266 Operating mechanism................. 267 Valve sizing...................... 268 Electrical parameters................. 269 Manual overrides................... 270

More information

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts 0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Refrigeration Solenoid Valves & 3-Way Heat Reclaim Valves

Refrigeration Solenoid Valves & 3-Way Heat Reclaim Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Refrigeration Solenoid s & 3-Way Heat Reclaim s Catalog D-1, May 2010

More information

Air Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 NPT

Air Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 NPT ir ctuated all Valves 3-Piece Stainless Steel, ull Port 1/4 to 3 SERIES eatures Spring Return or ouble cting ctuators ull Port direct mount ISO5211 valve Swing-out bolted body design for easy maintenance

More information

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2 SOLENOI VLVES no voltage release (lever type) manual reset construction 1/4 to 1/2 U 1 3 2 3/2 Series 307 FETURES Lever type Manual Reset function which means that the valve has to be energized as well

More information

Condensate Drain Valve Assemblies

Condensate Drain Valve Assemblies 4 Condensate Drain Valve Assemblies 2-way normally closed operation Compact design Adjustable timers with status indication www.ascovalve.com 1 4 Condensate Drain Valve Assemblies Compressed air is used

More information

Optional Features. Index. Index

Optional Features. Index. Index Optional Features Standard ASCO solenoid valves will meet the needs of most applications. However, there are times when fluids must be handled at higher temperatures, in less than ideal ambient locations,

More information

SKINNER Intrinsically Safe Series Four-Way

SKINNER Intrinsically Safe Series Four-Way SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air

More information

Gold Ring Two -Way, Three-Way and Four-Way Solenoid Valves. Catalog 7300A

Gold Ring Two -Way, Three-Way and Four-Way Solenoid Valves. Catalog 7300A Gold Ring Two -Way, Three-Way and Four-Way Solenoid Valves Catalog 7300A Table of Contents Introduction Product Overview...1 Condensed Valve Listing... 2-9 Valve Ordering Information...10-12 Gold Ring

More information

Solenoid Valves Catalogue

Solenoid Valves Catalogue Solenoid Valves Catalogue lcon Solenoid Valve Range US Keeping the World Flowing Contents Section Page Section Page Introduction 3 U Series 4 U Series Exd 6 U3/U33 Series 8 U3/U33 Series Exd 0 68 Series

More information

Poppet Valves Series

Poppet Valves Series Poppet Valves 750 Series ontents Section Page Introduction 750 Series Poppet Valve Pilot operated 4 /4 to / Pilot operated 5 /4 to Pilot operated 6 Pilot operated 7 /4 to / Pilot solenoid operated 8 /4

More information

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam. Steam Valve Series VN Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

VNA VNB SGC SGH VNC VNH VND VCC

VNA VNB SGC SGH VNC VNH VND VCC Steam Valve VN Series Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable

More information

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472 Data sheet 2-way solenoid valves with Clip-on coils for neutral liquids and gases January 200 DKACV.PD.200.K.22 520B472 2 DKACV.PD.200.K.22 Danfoss A/S 0-200 Contents 2-way solenoid valves with Clip-on

More information

SOLENOID VALVES direct operated core disc 1/4

SOLENOID VALVES direct operated core disc 1/4 SOLENOI VLVES direct operated core disc / N U NO / Series 70 FETURES Three-way solenoid valves with orifice and pipe connections in valve body enabling convenient installation ompact valve intended for

More information

SOLENOID VALVES no voltage release (lever type) manual reset construction 3/8 to 1

SOLENOID VALVES no voltage release (lever type) manual reset construction 3/8 to 1 SOLNOI VLVS no voltage release (lever type) manual reset construction 3/8 to N NO 3 2 3/2 Series 308 TURS Lever type Manual Reset function which means that the valve has to be energized as well as manually

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

SV321 & SV Way Normally Closed and Normally Open Pilot Operated Solenoid Valves

SV321 & SV Way Normally Closed and Normally Open Pilot Operated Solenoid Valves SV321 & SV421 2-Way and Pilot Operated Solenoid Valves Valcor General Purpose Series ESRIPTION pplication Features These 2-way piloted diaphragm solenoid valves are available in normally closed and normally

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8 G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications

More information

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility atalog Product atalog Setting a new standard for: Quality Reliability Value Global ompatibility Table of ontents 3- Valves 3 irect Acting Solenoid Valves (M3V) 4-5 3-Way Solenoid Valves (M3V) 6-7 4-Way

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4" to 1" NPT

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4 to 1 NPT 4 Solenoid and Piloted Piston Series Condensate Drain Brass or Stainless Steel Bodies 1/4" to 1" NPT 2/2 Features Designed to automatically drain condensate in compressed air systems Piloted piston assemblies

More information

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA Series V irect Operated Port Solenoid Valve for Oil Series V VX VN V VW V V P.-9 Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series V Kerosene, uel oil class (fuel oil ), Silicone

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Compact / Lightweight 2 Port Solenoid Valve

Compact / Lightweight 2 Port Solenoid Valve ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Instrument Ball Valves

Instrument Ball Valves www.swagelok.com Instrument all s 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150 (10 to 65 ) Low-temperature service option

More information

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B G31/41 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol G31/41: Universal

More information

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

3-Way Linked Globe Valve Assemblies with Linear Series Actuators Linked Globe Valve ssemblies with Linear Series ctuators Note: hoose a valve assembly having a close-off pressure capability sufficient for the application. Not all valve body and actuator combinations

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

Quick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories.

Quick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories. 36 Series Stainless Steel 2-way ull Port all Valve The 36 is a full port, 36 stainless steel, 3 piece ball valve. t is available with threaded ends (36N), socket weld ends (36S), or quick clamp ends with

More information

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments

More information

D I D /240 I. D x /240 I D / x x /24 I. D x /120

D I D /240 I. D x /240 I D / x x /24 I. D x /120 ndustrial ontrol Transformers lass 9070 www.square.com or the most up-to-date information The T units are designed for the global market and are the best choice when size and cost are of concern. This

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions OPEN-- FRAME, GENERAL PURPOSE, WATERTIG/EXPLOSIONPROOF SOLENOIDS r SERIES 8016G/H (Section1of2) SERVICE NOTICE ASCOr solenoid valves with design change letter G

More information

3/2 or 5/2 way solenoid valves. Direct NAMUR mount.

3/2 or 5/2 way solenoid valves. Direct NAMUR mount. 095 / or 5/ way solenoid valves. irect NMU mount. pplications 095 deally suited as pilot valves for single or double acting cylinders and actuators with NMU mount. ompact valve convertible from 5/ to /

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

SOLENOID VALVES direct operated core disc 1/4

SOLENOID VALVES direct operated core disc 1/4 SOLENOI VLVES direct operated core disc /4 N U NO / Series 4 FETURES ompact valve intended for single-acting actuator control Epoxy moulded coil for general service applications oils interchangeable without

More information

AIR RIDE SUSPENSION SYSTEMS

AIR RIDE SUSPENSION SYSTEMS AIR RIDE SUSPENSION SYSTEMS Solenoid Valves (Fast Valves) Valve Manifold Systems Pressure Switches Filters (Water Traps) Air Bellows & Fittings www.asconumatics.com 1 ASCO Numatics Air Ride Components

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information