Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies

Size: px
Start display at page:

Download "Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies"

Transcription

1 Constructions Suitable for - C to -5 C Ambient, 3 and Way Constructions Available Brass, Aluminum and Stainless Steel Bodies Air and Inert Gas Service

2 INDEX General Service Valves -Way/ Position 8 Aluminum Body 83 High Pressure 86/863 General Service Normally Open 6 86/863 General Service Normally Closed 8 3-Way/ Position 83 General Service 836 General Service 837 Quick Exhaust 83 General Service 6 83 Direct Mount High Flow Direct Acting 855 RedHat II Spool Valve -Way/ and 3 Position 83 Piston/Poppet 855 RedHat II Spool Valve Direct Mount 8 Special Service Valves Cryogenic and Liquid CO 3 Manual Reset 3 Low Power -. W 3 Low Power -.55 W 38 Intrinsically Safe and Non-Incendive Field Wiring Intrinsically Safe Manual Reset 5 Tamper Proof Manual Reset 5 ATEX 55 Air/Inert Gas Quality Statement for Low Ambient Valves DEWPOINT To prevent freezing of condensed water vapour in the valve, the air/inert gas must have a dewpoint at least F (8 C) below the minimum temperature to which any point of the system will be exposed. LUBRICATION The use of lubricators upstream of valves is NOT recommended. Likewise, air containing compressor carry over lubricants requires cleaning with suitable filters upstream of the valve. Hydrocarbon oil, with its characteristic viscosity increase at low temperatures, may cause the valve to operate erratically or to fail to operate. Note: For Engineering/Principle of Operation information refer to Cat. 35. Accessories Quick Exhaust/Shuttle Valve 57 Optional Features Explosionproof Junction Box 58

3 Direct Acting Aluminum Body Solenoid Valves /8" to 3/" NPT / 8 -WAY Features Lightweight, low-cost valves for air service F M APPROVED Ideal for low pressure applications Provides high flow, Cv up to 9.5 Air service Construction Valve Parts in Contact with Fluids Body Aluminum Seals, Diaphragms, Disc NBR Core Guide POM Rider Rings PTFE Core and Plugnut 3F Stainless Steel Springs* 3 Stainless Steel Shading Coil Copper * For 8H6, 8H7, 8H8, spring material is 7-7 PH NC Electrical Solenoid Enclosures Watt Rating and Power Standard Consumption Spare Coil Part Number Coil and AC General Purpose Explosionproof Class of VA VA Insulation Watts Holding Inrush AC AC F F Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). Must be specified when ordering. Other voltages available when required. Standard: RedHat II - Watertight, Types,, 3, 3S,, and X. Optional: RedHat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) Approvals CSA certified, UL listed and FM approved. Meets applicable CE directives.

4 -WAY / 8 Specifications Pipe Orifice Cv Flow Factor Min. NORMALLY CLOSED (Closed when de-energized) Operating Pressure Differential (psi) AC Fluid Temp. F Aluminum Body Watt Rating/ Class of Coil Insulation ➀ Air-Inert Gas AC Catalogue Number Ref. AC DC /8 5/ H6 6./F - / 5/ H7 6./F - 3/8 5/ H8 6./F - / 3/ G 3A./F - 3/ 3/ G3 3B./F - ➀ On 5 hertz service, the watt rating for the 6./F solenoid is 8. watts. Dimensions: inches (mm) Ref. H K L P W ins mm A ins mm B ins mm NPT BOTH ENDS Ref. 3A, 3B P K H / NPT IMPORTANT: Valves may be mounted in any position. L FLOW W.66 [] MOUNTING HOLES Ø.8 [Ø 7.] Ref. W / NPT CORED HOLES.35 [8.9] DEEP FOR.6-3 TH D FORMING SCREW.8 [.3].6 [5] NPT BOTH ENDS P H K.6 [.3] R.88 [R.] PLACES.9 [3].5 [6.] IN BOTTOM VIEW OF BODY L.5 [.9] PLACES.75 [9.].97 [5] FLOW 3

5 Pilot Operated High Pressure Solenoid Valves Stainless Steel Bodies /" NPT / 83 -WAY Features Rugged piston construction built to withstand pressure ratings to 5 psi Angle body design for high flows Ideal for high-pressure applications Mountable in any position Construction Body Seals and Disc Core Tube Core and Plugnut Core Spring Shading Coil Valve Parts in Contact with Fluids 3 Stainless Steel PTFE, NBR 35 Stainless Steel 3F Stainless Steel 3 Stainless Steel Silver NC Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC Explosionproof DC Watts Watts VA Holding VA Inrush AC DC F Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives.

6 -WAY / 83 Specifications Operating Pressure Differential (psi) AC DC Fluid Temp. F Stainless Steel Body Watt Rating/ Class of Coil Insulation Pipe Orifice Cv Flow Factor NORMALLY CLOSED (Closed when de-energized) Min. Air-Inert Gas Air-Inert Gas AC DC Catalogue Number Ref. AC DC / 3/ EFX83GMF/ /F.6/F Dimensions: inches (mm) Ref. H K L P W ins mm ins mm / NPT Ref. & 5 K P H OUTLET NPT PLACES INLET L W INLET LOCATED ON BOTTOM FOR 5

7 Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies Normally Open /8" to 3/8" NPT / WAY Features Reliable, proven design with high flows Small poppet valves for tight shutoff Wide range of elastomers for specialty service Mountable in any position Brass and stainless steel constructions Construction Valve Parts in Contact with Fluids Body Brass 33/3 Stainless Steel Seals and Discs NBR or Cast UR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Springs 3 Stainless Steel Shading Coil Copper Silver Stem PA NO Electrical Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number) See Optional Features Section for other available options. Options Mounting bracket (suffix MB) High Vacuum service (suffix VH; see Vacuum Section for more details.) Oxygen service (suffix N) Silicone Free (suffix SF) Elastomers: Low Temp. NBR (suffix A) Nominal Fluid Temp. Range AC & DC: - F to 67 F (- C to 75 C) Nominal Ambient Temp. Ranges AC Class F Coil Option: - F to 3 F (- C to 55 C) AC Class H Coil Option: - F to F (- C to 6 C) DC Class H Coil Option: - F to 3 F (- C to 55 C) Refer to Engineering Section for fluid and temperature compatibility. Note: ambient for explosionproof (EF) is 5 F (5 C) for AC, 3 F (55 C) for DC. Refer to Engineering Section for details. Approvals CSA certified. UL listed, as indicated. Meets applicable CE directives. Refer to Engineering Section for details. 6

8 -WAY / Specifications (English units) Operating Pressure Differential (psi) Fluid Watt Rating/Class Pipe Orifice Cv Max AC@3 F Max DC@3 F Temp F Catalogue Number of Coil Insulation Flow Air-Inert Lt. Air-Inert Lt. UL (in) (mm) Factor Gas Water 3 SSU Gas Water 3 SSU AC DC Brass Stainless Steel Ref Listing AC DC NORMALLY OPEN (Open when de-energized) /8 3/ H5A➀ - l 7./H.6/H /8 3/ H67A➀ l 7./H.6/H /8 3/ H55A➀ 86H68A➀ l./f.6/h /8 3/ H56A 86H69A l./f.6/h /8 3/ H57A 86H7A l 7./H.6/H /8 3/ H8A 86H36A l./f.6/h /8 / H58A 86H73A l 7./H.6/H /8 / H9A 86H37A l./f.6/h / 3/ H59A➀ - l 7./H.6/H / 3/ H98A➀ l 7./H.6/H / 3/ H6A➀ 86H99A➀ l./f.6/h / 3/ H6A 86H3A l./f.6/h / 3/ H6A 86H5A l 7./H.6/H / 3/ H6A 86H3A l./f.6/h / / H63A 86H9A l 7./H.6/H / / H6A 86H38A l./f.6/h / 5/ H6A 86H3A l 7./H.6/H / 5/ H63A 86HA l./f.6/h / 7/ H65A 86HA l 7./H.6/H / 7/ H6A 86H8A l./f.6/h / 9/ H66A 86H5A l 7./H.6/H / 9/ H65A 86H5A l./f.6/h 3/8 / HA 863HA 3 l 7./H.6/H 3/8 / H7A 863H8A 3 l./f.6/h 3/8 5/ HA 863H5A 3 l 7./H.6/H 3/8 5/ H7A 863H8A 3 l./f.6/h 3/8 7/ HA 863H6A 3 l 7./H.6/H 3/8 7/ H7A 863H8A 3 l./f.6/h 3/8 9/ H3A 863H7A 3 l 7./H.6/H 3/8 9/ H73A 863H83A 3 l./f.6/h ➀ Cast UR disc supplied as standard. l General Purpose Valve. Dimensions: inches (mm) Ref. H K L P W ins mm ins mm ins mm IMPORTANT: Valves may be mounted in any position. Ref. -3 W.3 [8] Ref. (/8" Pipe).59 [5] MOUNTING HOLES Mounting Dimensions Ref. 3 (3/8" Pipe).69 [8] MOUNTING HOLES FLOW M5 THREAD.5 [6.] MIN. FULL THREAD DEPTH. HOLES FOR MOUNTING.57 [].75 [9] MOUNTING HOLES K P H.3 [9] Ref. (/" Pipe).87 [.] MOUNTING HOLES.8 [.6] MOUNTING HOLES FLOW M5 THREAD. [6] MIN. FULL THREAD DEPTH HOLES FOR MOUNTING L ANPT PIPE THREAD ( PLACES).87 [.] MOUNTING HOLES FLOW M5 THREAD.3 [7.6] MIN. FULL THREAD DEPTH HOLES FOR MOUNTING Note: Mounting holes will accept a standard #-3 machine screw. 7

9 Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies Normally Closed /8" to 3/8" NPT / WAY Features Welded core tube provides higher pressure ratings F M APPROVED Reliable, proven design with high flows Small poppet valves for tight shutoff Wide range of elastomers for specialty service applications Mountable in any position Tapped mounting holes in body standard Construction Valve Parts in Contact with Fluids Body Brass Cast 3 Stainless Steel Seals and Discs NBR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Springs 3 Stainless Steel Shading Coil Copper Silver Electrical DC Watts Watt Rating and Power Consumption Spare Coil Part No. AC General Purpose Explosionproof VA Watts Holding VA Inrush AC DC AC DC Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages available when required. NC Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number) See Optional Features Section for other available options. 863 Nominal Ambient Temp. Ranges The nominal limitation of 3 F ( C) is advisable for any valve that might contain moisture (water vapour). AC: - F to 3 F (- C to 55 C) DC: - F to F (- C to C) - F to 3 F (- C to 55 C) Note: Max ambient for explosionproof (EF) is 5 F (5 C) for AC, 3 F (55 C) for DC. Optional: For AC, the max. ambient temperature is F (6 C) with Class H coil (with or without prefix EF) Refer to Engineering Section for details. Approvals CSA certified. UL listed, as indicated. Meets applicable CE directives. 8

10 -WAY / Specifications Pipe Orifice size Cv Flow Factor Operating Pressure Differential (psi) Catalogue Number Watt Rating/ Fluid Class of Coil AC@3 F DC@ F DC@3 F Temp. F Insulation Air-Inert Gas Water Lt. 3ssu Air-Inert Gas Water Lt. 3ssu Air-Inert Gas Water Lt. Oil 3ssu AC DC Brass Stainless Steel Ref. AC DC NORMALLY CLOSED (Closed when de-energized), NBR Disc /8 3/ H77A 86H78A 7./F.6/H /8 3/ H77A -.6/H /8 / H5A 86H7A 7./F.6/H /8 / H79A./F - / 3/ H9A 86H83A 3 7./F.6/H / 3/ H8A 86H8A 3./F.6/H / / HA 86H85A 3 7./F.6/H / / H3A - 3./F.6/H / / H8A 3./F - / 5/ HA 86H87A 3 7./F.6/H / 5/ HA - 3./F.6/H / 5/ HA 3./F - / 7/ HA 86H88A 3 7./F.6/H / 7/ H8A - 3./F.6/H / 7/ H6A 3./F - / 9/ HA 86H3A 3 7./F.6/H / 9/ HA - 3./F.6/H / 9/ H89A 3./F - 3/8 / H5A 863H9A 5 7./F.6/H 3/8 / H3A - 5./F.6/H 3/8 / H9A 5./F - 3/8 5/ H8A 863H93A 5 7./F.6/H 3/8 5/ HA - 5./F.6/H 3/8 5/ H33A 5./F - 3/8 7/ H6A 863H33A 5 7./F.6/H 3/8 7/ HA - 5./F.6/H 3/8 7/ H95A 5./F - 3/8 9/ HA 863H333A 5 7./F.6/H 3/8 9/ H5A 863H97A 5./F - For dimensions, consult factory. Dimensions: inches (mm) Ref. H K L P W ins mm ins mm ins mm Ref., 3, 5 K P W H L ANPT PIPE THREAD ( PLACES) Mounting Dimensions (/8" Pipe) (/" Pipe) (3/8" Pipe).3 [8].59 [5] MOUNTING HOLES.3 [9].87 [.] MOUNTING HOLES.57 [].75 [9] MOUNTING HOLES.69 [8] FLOW MOUNTING HOLES M5 THREAD.5 [6.] MIN.FULL THREAD DEPTH. HOLES FOR MOUNTING.87 [.] MOUNTING HOLES FLOW Note: Mounting holes will accept a standard #-3 machine screw. M5 THREAD.3 [7.6] MIN.FULL THREAD DEPTH HOLES FOR MOUNTING.8 [.6] MOUNTING HOLES FLOW M5 THREAD. [6] MIN. FULL THREAD DEPTH HOLES FOR MOUNTING 9

11 Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies /8" to /" NPT 3/ 83 Features Designed for high flow and high pressure service Direct acting, requires no minimum operating pressure Metal seating materials 3-WAY Construction Valve Parts in Contact with Fluids Body Brass 3 Stainless Steel Disc 33 Stainless Steel (Metal) Seats Phosphor Bronze 33 Stainless Steel Core Tube Core and Plugnut Springs 35 Stainless Steel 3F Stainless Steel 3 Stainless Steel, 7-7PH, or Iconel Shading Coil Copper Silver Gaskets NBR PTFE NC 3 NO Electrical Watt Rating and Power Consumption Spare Coil Part Number U Standard Coil AC Explosionproof and Class of Insulation DC Watts Watts VA Holding VA Inrush AC DC F H Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Solenoid Enclosures Standard: RedHat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9; RedHat - Explosionproof and Watertight, Types 3,, X, 7, and 9. See footnote on next page. For Optional Features, consult factory. Nominal Ambient Temp. Ranges Class F Coils AC: - F to 5 F (- C to 5 C) Class H Coils AC: - F to F (- C to 59 C) Class H Coils DC: - F to 77 F (- C to 5 C) ( F/ C occasionally) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives.

12 3/ 83 3-WAY Specifications Pipe Orifice METAL SEATS AND DISCS Cv Flow Factor AC Operating Pressure Differential (psi) Air-Inert Gas DC Fluid Temp. F Brass Body NC/NO Univ. NC/NO Univ. AC DC Catalogue Number Stainless Steel Body Add Suffix "F" for NC, "G" for NO, "U" for Univ. ➀ ➂ Ref. Catalogue Number Watt Rating/ Class of Coil Insulation ➂ Ref. AC DC /8 / EFX83D55MF/ /H /8 / EFX83G55MF/ /F - /8 3/ EFX83D3MF/ /H /8 3/ EFX83G3MF/ /F - / 3/ EFX83D58MF/ /H / 3/ EFX83G58MF/ /F - / / EFX83A8MF/ /H / / EFX83G8MF/ /F - / / EFX83D6MF/666 ➁ - - 8/H - 3/8 / EFX83BMF/ /H 3/8 / EFX83GMF/666./F - 3/8 / EFX83A8MF/ /H 3/8 / EFX83G8MF/ /F - 3/8 / EFX83D9MF/666 ➁ - - 8/H - 3/8 / EFX83BMF/666 ➁ 8/H - 3/8 5/ EFX83D6MF/666 EFX83BMF/ /H 3/8 5/ EFX83G6MF/666 EFX83GMF/666./F - 3/8 3/ EFX83D7MF/666 EFX83B3MF/ /H 3/8 3/ EFX83G7MF/666 EFX83G3MF/666./F - / 5/ EFX83D68MF/666 EFX83B3MF/ /H / 5/ EFX83G68MF/666 EFX83G3MF/666 3./F - / 3/ EFX83D76MF/666 EFX83BMF/ /H / 3/ EFX83G76MF/666 EFX83GMF/666 3./F - ➀ NC = Normally Closed: Exhaust pressure when de-energized. NO = Normally Open: Applies pressure when de-energized. Univ. = Universal: Pressure at any port. ➁ "EF" Prefix variations are suitable for enclosures Types 3,, 7 (C&D), and 9 (E) only and have a temperature range code T3A. ➂ For dimensions, consult factory. Dimensions: inches (mm) Ref. H K L P R S W T ins mm ins mm ins mm IMPORTANT: Valves must be mounted vertical and upright. Ref.,, 3 Flow Diagrams Normally Closed (Suffix "F") De-energized Energized SOL PRESS. SOL CYL. CYL. EXH. 3 Normally Open (Suffix "G") De-energized Energized PRESS. EXH. 3 SOL SOL EXH. EXH. CYL. CYL. PRESS. 3 Universal (Suffix "U") De-energized Energized PRESS. 3 SOL SOL 3 3

13 Air Piloted Spring Return Shutdown System General Service Solenoid Valves Brass or Stainless Steel Bodies Air and Inert Gas /" to /" NPT 3/ 836 Features Brass body construction for general atmospheres; stainless steel for corrosive atmospheres Can be internally piloted, or externally piloted When externally piloted, loss of electrical power or auxiliary air exhausts air from the actuator and shifts process valve to its original position When internally piloted, loss of electric power returns the valve to its original position 3-WAY Construction Valve Parts in Contact with Fluids Body Brass 36 Stainless Steel End Plate 3 Stainless Steel 36 Stainless Steel Seals and Discs Low Temp NBR NC E P A Core Tube 35 Stainless Steel NO Core Guide POM Shading Coil Copper Silver Electrical Watt Rating and Power Consumption Spare Coil Part Number Standard Coil and Class of Insulation Solenoid Enclosures AC Explosionproof (EF) Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Explosionproof (EV) DC VA Watts Watts Holding VA Inrush AC DC AC DC F Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts, AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives. Installation All valves may be mounted in any position. 36 Stainless Steel mounting brackets available from ASCO. Add suffix MB.

14 3/ WAY Specifications Pipe Orifice CV Flow Factor Min. NORMALLY CLOSED (Closed when de-energized) Air Press.(psi) Catalogue Number Fluid Temp. F Watt Rating/ Class of Coil Insulation AC DC Brass Body Stainless Steel Ref. AC DC AC DC / 5/6.5 ➀ 5 EFX836GMF/5 EVX836G8MF/5 8./F.6/F 3/8 5/6.6 ➀ 5 EFX836GMF/5 EVX836G8MF/5 8./F.6/F 3/8 5/8 ➁ 5 EFX836G3MF/5-3 8./F.6/F / 5/8 ➁ 5 EFX836GMF/5 EVX836G8MF/5 3 8./F.6/F ➀ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph below for pilot line pressure vs. mainline pressure. Minimum psi operating pressure differential when selection gasket is in the internal position. ➁ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph below for pilot line pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. IMPORTANT: Internal mode Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area and unrestricted. ASCO flow controls and similar components must be installed in the cylinder lines only. Dimensions: inches (mm) MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION Ref. PILOT LINE PRESSURE (psi) MAINLINE PRESSURE (psi) Ref. 3 INTERNAL PILOTING MODE FLOW DIAGRAMS De-Energized Energized PILOT EXH PILOT EXH (main) EXH (main) EXH CYL CYL PRESS PRESS EXTERNAL PILOTING MODE FLOW DIAGRAMS De-Energized with Auxiliary Pressure Applied (main) EXH PILOT EXH AUX Energized with Auxiliary Pressure Applied (main) EXH PILOT EXH AUX CYL CYL PRESS PRESS 3

15 Pilot Operated Quick Exhaust Solenoid Valves Brass or Stainless Steel Bodies /" NPT 3/ 837 Features Designed for quick venting to psi through the exhaust orifice 3-WAY Resilient seated poppets for tight shutoff Air is exhausted to quickly shift control valves Multi-industry applications Mountable in any position Construction Valve Parts in Contact with Fluids Body Brass 3 Stainless Steel Seals and Disc NBR (PA upper disc) Diaphragm CR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel and 7-7 PH Stainless Steel Shading Coil Copper Silver NC NO 3 Electrical Watt Rating and Power Spare Coil Standard Consumption Part Number Coil and AC Explosionproof Class of VA VA Insulation Watts Holding Inrush AC F Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives. Important A Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only.

16 3/ WAY Specifications Pipe Orifice Cv Flow Factor Operating Pressure Differential (psi) AC Fluid Temp. F Brass Body Stainless Steel Body Watt Rating/ Class of Coil Insulation Press. Exh. Press. Exh. Min. Air-Inert Gas AC Catalogue Number Ref. Catalogue Number Ref. AC NORMALLY CLOSED (Closed when de-energized) / 3/3 / EFX837G35MF/883 EFX837G36MF/883./F NORMALLY OPEN (Open when de-energized) / 3/3 / EFX837G53MF/ /F Dimensions: inches (mm) Ref. H K L P W ins mm ins mm Ref., 5

17 Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies /8" to /" NPT 3/ 83 Features All NPT connections are in the valve body to allow in-line piping 3-WAY No Minimum Operating Pressure Differential required Broadest range of applications Mountable in any position Construction Valve Parts in Contact with Fluids Body Brass 33 Stainless Steel Seals and Disc NBR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Shading Coil Copper Silver Disc-Holder POM Core Guide POM (. and 7. Watt only) NC NO 3 U Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F F Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. 83 /" NPT Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals Brass Body: CSA certified, UL listed solenoid. Meets applicable CE directives. Stainless Steel: CSA certified. UL listed General Purpose Valves. Meets applicable CE directives. 6

18 3/ 83 3-WAY Specifications Pipe Orifice Cv Flow Factor UNIVERSAL OPERATION (Pressure at any port) Operating Pressure Differential (psi) Fluid Temp. F Brass Body ➁ Stainless Steel Body Watt Rating/ Class of Coil Insulation AC DC Air-Inert Gas Air-Inert Gas AC DC Catalogue Number ➀ Ref. Catalogue Number ➀ Ref. AC DC /8 / EFX83GMF/5 83G 7./F.6/F /8 3/ EFX83G3MF/5 83G 7./F.6/F /8 / EFX83GMF/5 83G3 7./F.6/F / / EFX83G7MF/5 - -./F.6/F / / G3 3 7./F.6/F / 3/ EFX83G7MF/5 83G 3 7./F.6/F / / EFX83G76MF/5 83G 3 7./F.6/F / / EFX83G78MF/5 - -./F.6/F NORMALLY CLOSED (Closed when de-energized) /8 / EFX83G5MF/5 83G 7./F.6/F /8 3/ EFX83G6MF/5 83G5./F.6/F /8 / EFX83G7MF/5 83G6./F.6/F / / EFX83G8MF/5 83G3 3 7./F.6/F / 3/ EFX83G8MF/5 83G 3./F.6/F / / EFX83G86MF/5 83G3 3./F.6/F / / EFX83G88MF/5 - -./F.6/F NORMALLY OPEN (Open when de-energized) /8 / EFX83G8MF/5 83G7 7./F.6/F /8 3/ EFX83G9MF/5 83G8./F.6/F /8 / EFX83GMF/5 83G9./F.6/F / / EFX83G9MF/5 83G3 3 7./F.6/F / 3/ EFX83G9MF/5 83G 3./F.6/F / / EFX83G96MF/5 83G5 3./F.6/F / / EFX83G98MF/5 - -./F.6/F ➀ For dimensions, consult factory. ➁ Stainless steel constructions standard rated - F (- C) ambient temperature. EFX prefix and TPL # not required. 7

19 Direct Acting Direct Mount Pilot Valves Brass or Stainless Steel Bodies /" NPT 3/ 83 Direct Mount Features Mount directly to spring return actuators with NAMUR interface 3-WAY Same poppet valve performance as in standard 83 valves Integral breather block prevents ingestion of contaminates or corrosives Variety of flow and pressure ratings Mountable in any position Construction Valve Parts in Contact with Fluids ➀ Body Brass 33 Stainless Steel Seals and Discs Core Tube Core and Plugnut NBR 35 Stainless Steel 3F Stainless Steel Core Springs 3 Stainless Steel Shading Coil Copper Silver Disc-Holder POM NC 3 Core Guide POM (. and 7. watts only) ➀ Consult factory for constructioin details on catalogue numbers 83P7 and 83P7. Electrical Standard Coil and Class of Insulation DC Watts ➀ Watt Rating and Power Consumption Watts Spare Coil Part Number AC General Purpose Explosionproof VA Holding VA Inrush AC DC AC DC F F F Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. ➀ Consult factory for electrical information on Watt catalogue numbers 83P7 and 83P7. Solenoid Enclosures RedHat II Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) For Optional Features, consult factory. RedHat Next Generation Standard: Watertight, Types,, 3, 3S, 3R,, and X. Optional: Class I, Division for Hazardous Locations/Watertight. Meets Types through X and UL listed and CSA certified for Class I, Division, Groups A, B, C and D and Class II, Division, Groups F and G. (To order, add prefix EE to catalogue number.) Nominal Ambient Temp. Ranges RedHat II AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) RedHat Next Generation AC/DC: - F to F (- C to 6 C) Approvals 83: UL component and CSA certified. EFX83: UL component and CSA certified solenoid. 8

20 3/ 83 Direct Mount 3-WAY Specifications Pipe Orifice Cv Flow Factor NORMALLY CLOSED (Closed when de-energized) Operating Pressure Differential (psi) Watt Rating/ Air-Inert Gas Fluid Temp. F Brass Body Stainless Steel Body Class of Coil Insulation AC DC AC DC Catalogue Number Catalogue Number Ref. AC DC / / EFX83G7MF/5 EFX83G7MF/5 6./F.6/F / 3/3. 8 EFX83G7MF/5 EFX83G7MF/5 6./F.6/F / / EFX83G73MF/5 83G73 ➀ 7./F.6/F / 3/ EFX83G7MF/5 83G7 ➀./F.6/F / 3/ P7 ➁ 83P7 ➁ 8 /H /H / / EFX83G75MF/5 83G75 ➀ 7./F - ➀ Standard rated - F (- C) ambient temperature. EFX prefix and TPL # not required. ➁ RedHat Next Generation Valve. Dimensions inches (mm) Ref. Ref. Ref. 8 C B 3 D / NPT.9.95 / ANPT H / ANPT 3 Ø. x.5 DEEP FOR POSITIONING DOWEL FOR M5 SCREWS, PLACES.8 FOR.9-3 UNC-A &.9-3 UNF-A SCREWS, PLACES 9

21 Balanced Poppet Type High Flow Direct Acting Valves Brass, Aluminum and 36 Stainless Steel Bodies /" NPT 3/ 837 Features Designed for high flow piloting with no minimum operating pressure required; e.g. power plants, refineries, chemical processing 3-WAY Balanced Poppet construction for high flow at minimum power levels PTFE rider rings and graphite-filled seals reduce friction and eliminate sticking to provide exceptional service life 36 Stainless Steel construction for highly corrosive atmospheres NAMUR direct mount construction available. See specification chart Construction Valve Parts in Contact with Fluids Body Brass 36 Stainless Steel Aluminum Core Tube 35 Stainless Steel Stem and Insert 33 Stainless Steel Core and Plugnut 3F Stainless Steel O-ring Holder 3F Stainless Steel Springs 3 Stainless Steel Seals and Discs VMQ Rider Ring PTFE Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F F-NAMUR Standard Voltages: /5-6, /5-6, /5-6, and 8/5-6, or 6,,,, and DC. U 3 Solenoid Enclosures Standard: For Brass and Aluminum Valves: Standard Solenoid enclosure is Types,,, 3, 3S,, and X. For 36 Stainless Steel valves: Standard Solenoid enclosure is Explosionproof and Watertight Types 3, 3S,, X, 6, and 6P. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF or, for Explosionproof Stainless Steel trim and hub on Brass-Bodied valves, add EV to catalogue number.) For Optional Features, consult factory. Nominal Ambient Temp. Ranges - F to 3 F (- C to 55 C) Approvals CSA certified. UL listed General Purpose Valves. Meets applicable CE directives.

22 3/ WAY Specifications Pipe Orifice Cv Flow Factor Maximum Operating Pressure Differential (psi) Brass Body 36 Stainless Steel Body Watt Rating/ Class of Coil Insulation Ports - Ports -3 Air-Inert Gas Fluid Temp. F Catalogue Number Catalogue Number Ref. AC DC UNIVERSAL LOW-TEMPERATURE OPERATION (pressure at any port) - SIL 3 Certified by Exida ➀ / / G5./F.6/F / / EV837G5./F.6/F ➀ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. SIL 3 Certified by Exida, only valid when used as Normally Closed. Pipe Orifice Cv Flow Factor Maximum Operating Pressure Differential (psi) Aluminum Body Stainless Steel Body Watt Rating/ Class of Coil Insulation Ports - Ports -3 Air-Inert Gas Fluid Temp. F Catalogue Number Catalogue Number Ref. AC DC UNIVERSAL LOW-TEMPERATURE OPERATION - NAMUR Direct Mount / / G53 EV837G55./F.6/F Dimensions: inches (mm) FLOW DIAGRAMS Ref. OPERATION DE-ENERGIZED ENERGIZED NORMALLY CLOSED PRESSURE AT NORMALLY OPEN PRESSURE AT 3 3 UNIVERSAL PRESSURE AT ANY PORT 3 3 IMPORTANT: Valves may be mounted in any position. Ref.

23 Pilot Operated High FLow RedHat II Spool Valves Brass and Stainless Steel Bodies /" NPT 3/ 855 Features Compact Spool Valve 3-WAY Single and dual solenoid constructions available Unique design combines hard T-seals and flexible o-rings, provides bubble-tight shutoff, resistance to dirt and multimillion cycle life controlling air or inert gas Construction Valve Parts in Contact with Fluids Body Brass 36L Stainless Steel End Cover (Spring end) Brass 36L Stainless Steel Spool Valve Internals Brass, POM Pilot End Covers Brass 36L Stainless Steel Core Tube Stainless Steel Core and Plugnut Stainless Steel Springs Stainless Steel Seals and Discs NBR Top Disc PA Core Guide POM Seat and Seat Insert Brass, POM Shading Coil Copper Rider Ring (low power) PTFE Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F Standard Voltages:,,, 8 volts AC, 6 Hz (, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges Body Material Brass Stainless Steel Description AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Approvals CSA certified, UL listed solenoids. Meets applicable CE directives.

24 3/ WAY Specifications Body Material Pipe Orifice Cv Flow Factor Single Solenoid Dual Solenoid Operating Pressure Operating Pressure Watt Rating/ Differential (psi) Fluid Differential (psi) Fluid Class of Coil Air-Inert Gas Temp. F Air-Inert Gas Temp. F Insulation Min. AC DC AC DC Catalogue Number Ref. Min. AC DC AC DC Catalogue Number Ref. AC DC Brass EF855G7 ➀➂ EF855G8 ➀ / / L Stainless Steel EV855G3 ➁ EV855G ➁./F.6/F ➀ Brass construction supplied standard with EF solenoid. ➁ Stainless steel construction supplied standard with EV solenoid. ➂ SIL 3 Certified by EXIDA - Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. Dimensions inches (mm) Series 855 NPT / L ➀ 5. (3) L ➀ 6.73 (7) H.38 () H. (8) W.77 (5) Ref. 3. (76.7).3 (5.6) / NPT ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H 3 /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand 3

25 Pilot Operated Piston/Poppet Solenoid Valves Brass Body /" to " NPT / 83 Features Sturdy, robust construction Piston-operated poppet design provides high flow Wide range of sizes and flow rates Single or dual solenoid constructions Dual solenoid can be shifted with a momentary signal and remain in position even if electrical power is lost Mountable in any position -WAY Construction Valve Parts in Contact with Fluids Body Brass Seals and Disc NBR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Springs 3 Stainless Steel / 7-7PH Stainless Steel Shading Coil Copper Pilot Seat Cartridge and Disc-Holder POM Shaft Gasket PA B E B E A P A P Electrical Standard Coil and Class of Insulation DC Watts Watt Rating and Power Consumption AC Spare Coil Part Number Explosionproof Watts VA Holding VA Inrush AC DC F F F Dual Solenoid Operation: Minimum coil on-time for dual solenoid valves is.3 seconds on air service and. seconds on liquids. Caution: Do not energize both solenoids simultaneously. Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals CSA certified solenoid. Meets applicable CE directives. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Important A Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. Loss of air pressure may allow valve to shift on dual solenoid constructions.

26 / 83 Specifications -WAY Pipe SINGLE SOLENOID Orifice Press. Cv Flow Factor Exh. ➀ Min. Operating Pressure Differential (psi) AC Air-Inert Gas DC Fluid Temp. F Brass Body Air-Inert Gas AC DC Catalogue Number Watt Rating/ Class of Coil Insulation Ref. AC DC / / EFX83G7MF/8897./F.6/F 3/8 3/ EFX83G7MF/8897./F.6/F / 3/ EFX83G7MF/8897./F.6/F 3/ 3/ EFX83G76MF/ /F.6/F 3/ EFX83G78MF/ /F.6/F DUAL SOLENOID ➀ / / EFX83GMF/ /F.6/F 3/8 3/ EFX83G8MF/ /F.6/F / 3/ EFX83G8MF/ /F.6/F ➀ On 5 hertz service, the watt rating for the 6./F solenoid is 8. watts. Dimensions inches (mm) Ref. ØD E F G H J K L N P W X Y Z Exhaust Pipe ins. Ø /8 mm Ø /8 ins. Ø / mm Ø / 3 ins. Ø mm Ø ins. Ø /8 mm Ø /8 6 ins. Ø / mm Ø / Ref - 3 Ref - 6 Ref. - 6 / NPT N X E PRESS EXH. MTG. HOLES DIA D / NPT H P K L F K P H CYL B J CYL A PRESS EXH. Z Y G W PRESS EXH. 5

27 Pilot Operated High Flow RedHat II Spool Valves Brass and Stainless Steel Bodies /" NPT 5/ 5/3 855 Features Compact Spool Valve Single and dual solenoid constructions available Unique design combines hard T-seals and flexible o-rings, provides bubble-tight shutoff, resistance to dirt and multimillion cycle life controlling air or inert gas -WAY Construction Valve Parts in Contact with Fluids Body Brass 36L Stainless Steel End Cover (Spring end) Brass 36L Stainless Steel Spool Valve Internals Brass, POM Pilot End Covers Brass 36L Stainless Steel Core Tube Stainless Steel Core and Plugnut Stainless Steel Springs Stainless Steel Seals and Discs NBR Top Disc PA Core Guide POM Seat and Seat Insert Brass, POM Shading Coil Copper Rider Ring (low power) PTFE 5/ Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption AC Spare Coil Part Number Explosionproof VA Inrush AC DC DC Watts Watts VA Holding F Standard Voltages:,,, 8 volts AC, 6 Hz (, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges Body Material Brass Stainless Steel Description AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Approvals CSA certified, UL listed solenoids. Meets applicable CE directives. 6

28 5/ 5/3 855 Specifications Body Material Pipe Orifice Cv Flow Factor Single Solenoid Dual Solenoid Operating Pressure Operating Pressure Watt Rating/ Differential (psi) Fluid Differential (psi) Fluid Class of Coil Air-Inert Gas Temp. F Air-Inert Gas Temp. F Insulation Min. AC DC AC DC Catalogue Number Ref. Min. AC DC AC DC Catalogue Number Ref. AC DC -WAY Brass 5/ EF855G9 ➀ EF855G ➀ / / L Stainless Steel 5/ EV855G ➁ EV855G ➁./F.6/F ➀ Brass construction supplied standard with EF solenoid. ➁ Stainless steel construction supplied standard with EV solenoid. Dimensions inches (mm) Series 855 NPT / L ➀ 5.63 (3) L ➀ 7. (83) H.38 () H. (8) W.77 (5) ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Ref. 3. (76.7).3 (5.6) / NPT Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H H 3 /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand 7

29 Pilot Operated High Flow Direct Mount Spool Valves Brass and Stainless Steel Bodies /" NPT 3/ 5/ 855 Direct Mount Features Compact Spool Valve convertible from 3/ to 5/ with flow plates Mount directly to actuators with NAMUR interface per VDI/VDE 385 Single and dual solenoid constructions available Integral Breather Block vents to spring side of actuator to exhaust, preventing corrosion of the actuator Unique design combines hard T-seals and flexible o-rings, provides bubble-tight shutoff, resistance to dirt and multimillion cycle life controlling air or inert gas -WAY Construction Valve Parts in Contact with Fluids ➀ Body Brass 36L Stainless Steel End Cover (Spring end) Brass 36L Stainless Steel Spool Valve Internals Brass, POM Pilot End Covers Brass 36L Stainless Steel Core Tube Stainless Steel Core and Plugnut Stainless Steel Springs Stainless Steel Seals and Discs NBR Top Disc PA Core Guide POM Seat and Seat Insert Brass, POM Shading Coil Copper Rider Ring (low power) PTFE ➀ Consult factory for construction details on catalogue numbers EE855P and EE855P9. 3/ 5/ Electrical Standard Coil and Class of Insulation Solenoid Enclosures ➀ Watt Rating and Power Consumption AC Spare Coil Part Number Explosionproof VA Inrush AC DC DC Watts Watts VA Holding F Standard Voltages:,,, 8 volts AC, 6 Hz (, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. ➀ Consult factory for electrical information and standard voltages on catalogue numbers EE855P and EE855P9. RedHat II Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. RedHat Next Generation Standard: Class I, Division for Hazardous Locations/Watertight. Meets Types through X and UL listed and CSA certified for Class I, Division, Groups A, B, C and D and Class II, Division, Groups F and G. Nominal Ambient Temp. Ranges RedHat II AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) RedHat Next Generation AC/DC: - F to F ( C to 6 C) Approvals CSA certified, UL listed solenoids. Meets applicable CE directives. 8

30 3/ 5/ 855 Direct Mount -WAY Specifications Body Material Pipe Orifice Cv Flow Factor Operating Pressure Differential (psi) Air-Inert Gas Min. AC Single Solenoid Fluid Temp. F Catalogue DC AC DC Number Ref. Min. Operating Pressure Differential (psi) Air-Inert Gas AC Fluid Temp. F Dual Solenoid Watt Rating/ Class of Coil Insulation Catalogue DC AC DC Number Ref. AC DC Brass 3/, 5/ ➂ / / EF855G3 ➃ 3 5 EF855G ➃./F.6/F 36L Stainless Steel 3/, 5/ ➂ / / EE855P9 ➀ ➁ /H /H / / EV855G9 ƒ 3 5 EV855G ƒ./f.6/f ➀ RedHat Next Generation Valve. ➁ Consult factory for dimensions. ➂ /8 inch NPT exhaust. ➃ Brass construction supplied with EF solenoid. ƒ Stainless steel construction supplied standard with EV solenoid. Dimensions inches (mm) Series 855 NPT / L ➀.96 (6) L ➀ 6.5 (65) H.38 () H.57 () W.77 (5) ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Ref. H H 3. (76.7).3 (5.6) 3 /8 NPT / NPT / NPT Add Suffix MO MI MH MS Optional Manual Operators ➀ Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot Momentary push in by hand Push and turn to lock by hand ➀ For construction references and only 855 NAMUR Footprint.95 ().6 (3) H H 3. (76.7).3 (5.6).95 () W 855 NAMUR Footprint Ref. (855) / NPT (8553) / NPT (3) / NPT /8 NPT AUX. PRESSURE PORT L Add Suffix MO MI MH L Optional Manual Operators Series 855 (5/3) NPT / L ➀ - L ➀ 7. (89) H.38 () H.57 () W.77 (5) ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot Momentary push in by hand W /8 NPT AUX. PRESSURE PORT L MS Push and turn to lock by hand L 9

31 Direct Acting Pilot Operated Cryogenic and Liquid CO Valves Brass Body /8" to /" NPT / Cryo/ LCO Features LT suffix valves are built to control cryogenic fluids, including liquid nitrogen (-3 F/-9 C), liquid argon (-33 F/-8 C), and liquid oxygen (-97 F/-8 C) All suffix LT valves are degreased, cleaned, tested free of moisture, and black light tested for hydrocarbons Liquid CO valves are suitable for remote mounting or for direct mounting to the refrigerated component by using four-hole bracket, provided Construction Body: Cryogenic Valves Valve Parts in Contact with Fluids Brass % ) SPECIAL SERVICE VALVES Body: LCO Valves Seals Disc Core and Plugnut Core Spring Shading Coil Seats Nickel-Plated Brass PTFE and/or Clad Copper/UR PTFE/UR (86 only) 3F Stainless Steel or 9 FM Alloy 3 Stainless Steel Copper Stainless Steel (86 Series) NC Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Solenoid Enclosures Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F F F H Standard Voltages:,,, 8 volts AC, 6 Hz. 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) See Optional Features Section for other available options. Nominal Fluid Temp. Ranges AC Cryogenic Valves: -3 F to 5 F (-96 C to 66 C) DC Cryogenic Valves: -3 F to F (-96 C to 9 C) All Liquid CO Valves: -75 F to F (-59 C to 9 C) Refer to Engineering Section for details. Nominal Ambient Temp. Ranges AC Construction: - F to 5 F (- C to 5 C) 86/863 Series: - F to 3 F (- C to 55 C) DC Construction: - F to F (- C to C) 86/863 Series: - F to 3 F (- C to 55 C) Refer to Engineering Section for details. Approvals CSA certified. Meets applicable CE directives. Refer to Engineering Section for details. 3

32 / Cryo/ LCO SPECIAL SERVICE VALVES Specifications (English units) Operating Pressure Differential (psi) Watt Rating/ Class of Coil Pipe Orifice Cv Insulation Flow Factor Min. AC F 3 F Catalogue Number Ref. AC DC CRYOGENIC SERVICE - NORMALLY CLOSED (Closed when de-energized) /8 / HLT./F.6/H /8 / H5LT 7./F.6/H / / H3LT./F.6/H / / HLT 7./F.6/H / 7/ H8LT./F.6/H / 7/ HLT 7./F.6/H / 9/ HLT./F.6/H / 9/ HLT 7./F.6/H 3/8 / H3LT./F.6/H 3/8 / H5LT 7./F.6/H 3/8 7/ HLT./F.6/H 3/8 7/ H6LT 7./F.6/H 3/8 9/ H5LT./F.6/H 3/8 9/ HLT 7./F.6/H / 5/ GLT 3 7./H.6/H 3/ 3/ G3LT 3 7./H.6/H G78LT 7./F.6/H / / G8LT 5 7./F.6/H / /.5 5-8G8LT 6 7./F.6/H LIQUID CO SERVICE - NORMALLY CLOSED (Closed when de-energized) /8 3/6.6-86G /F 8.6/F /8 3/ G 7 3.8/F 8.6/F Must use tubing with an I.D. no larger than the outlet port orifice to locate the refrigeration point downstream and to prevent freezing of the CO inside the valve. For 86 & 863 Series, AC pressure ratings are at 3 F ambient; for all other series, AC pressure ratings are at 5 F. Consult factory for dimensions. Specifications (Metric units) Operating Pressure Differential (bar) Watt Rating/ Class of Coil Pipe Orifice Kv Flow Insulation Factor (mm) (m 3 /h) Min. AC C 55 C Catalogue Number Ref. AC DC CRYOGENIC SERVICE - NORMALLY CLOSED (Closed when de-energized) / HLT./F.6/H / H5LT 7./F.6/H / H3LT./F.6/H / HLT 7./F.6/H / H8LT./F.6/H / HLT 7./F.6/H / HLT./F.6/H / HLT 7./F.6/H 3/ H3LT./F.6/H 3/ H5LT 7./F.6/H 3/ HLT./F.6/H 3/ H6LT 7./F.6/H 3/ H5LT./F.6/H 3/ HLT 7./F.6/H / GLT 3 7./H.6/H 3/ G3LT 3 7./H.6/H G78LT 7./F.6/H / G8LT 5 7./F.6/H / G8LT 6 7./F.6/H LIQUID CO SERVICE - NORMALLY CLOSED (Closed when de-energized) / G /F 8.6/F /8.7-86G 7 3.8/F 8.6/F Must use tubing with an I.D. no larger than the outlet port orifice to locate the refrigeration point downstream and to prevent freezing of the CO inside the valve. For 86 & 863 Series, AC pressure ratings are at 55 C ambient; for all other series, AC pressure ratings are at 5 C. 3

33 Universal Operation Manual Reset Solenoid Valves Brass or Stainless Steel Bodies /" to /" NPT 3/ Manual Reset Features High flow/high-pressure bodies with manual reset to prevent inadvertent valve start-up Once tripped, can only be manually reset Electrically Tripped (trips when energized) or No Voltage Release (trips when de-energized) Available for Latched Open or Latched Closed operation Ideal for controlling critical processes Construction Valve Parts in Contact with Fluids Body Brass Stainless Steel Stem 33 Stainless Steel Springs 3 Stainless Steel Pilot Seat Cartridge POM (when listed) Disc, Diaphragm, Seat NBR, PA, PTFE, or Stainless Steel, as listed SPECIAL SERVICE VALVES Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number VA Inrush AC DC AC DC Watts Watts VA Holding F H Standard Voltages:,,, 8 volts AC, 6 Hz. 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 7 (C and D), and 9. For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to F (- C to C) DC: - F to 77 F (- C to 5 C) Approvals CSA certified solenoid. Some constructions meet shock and vibration ISA S7.3C. Operation Alternatives Electrically Tripped Manually move the lever to the latched position with the solenoid de-energized. Trips when solenoid is energized. Once tripped, the lever may be cycled causing the valve discs to open and close. No Voltage Release Manually move the lever to the latched position with the solenoid energized. Trips when solenoid is de-energized. Once tripped, the lever may be cycled causing the valve discs to open and close. 3

34 3/ Manual Reset SPECIAL SERVICE VALVES Specifications Pipe Orifice Cv Flow Factor Watt Rating/ Operating Pressure Fluid ➂ Class of Coil Differential (psi) Temp. F No Voltage Release Electrically Tripped Flow Insulation Min. AC DC AC DC Catalogue Number Catalogue Number Ref. Diagram AC DC UNIVERSAL OPERATION (Except as Noted ➀ ), Brass Body with NBR Disc/Diaphragm (CA Pilot Cartridge) for Air-Inert Gas. This group of valves meets shock and vibration ISA S7.3C. / / EFX838BMF/7687 EFX83BMF/7687 B /F 36./H / 5/8 ➃ EFX838CMF/7687 ➀➁ EFX83CMF/7687 ➀➁ C /F 36./H UNIVERSAL OPERATION, Brass Body with Stainless Steel Seats and Discs for Air-Inert Gas / / EFX838MF/7687 EFX83MF/7687 A /F 36./H UNIVERSAL OPERATION, Stainless Steel Body with FKM Discs for Air-Inert Gas / / EFX838AMF/7687 EFX83AMF/7687 B /F 36./H UNIVERSAL OPERATION, Stainless Steel Body with Stainless Steel Seats and Discs for Corrosive Service / 5/ EFX8387MF/757 EFX837MF/ A /F - / 5/ EFX8387MF/7687 EFX837MF/ A - 36./H ➀ When ordering, specify suffix "F" for Normally Closed construction or Suffix "G" for Normally Open construction. ➁ Supplied with CA pilot cartridge. ➂ For dimensions, consult factory. ➃ -5 mainline pressure. Valve is externally piloted and requires a minimum pilot/auxiliary pressure of 5- psi. See graph below for mainline vs. pilot line pressure requirements. Flow Diagrams PILOT LINE PRESSURE (psi) MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION MAINLINE PRESSURE (psi) Electrically Tripped and No Voltage Release Constructions Flow Diagram A Latched Unlatched Flow Diagram B Latched Unlatched Port Port 3 3 Port Port 3 Port Port 3 Flow Diagram C Normally Open Normally Closed Unlatched Latched Unlatched Latched A (Cyl.) A (Cyl.) A (Cyl.) A (Cyl.) E (Exh.) P (Press.) E (Exh.) P (Press.) E (Exh.) P (Press.) E (Exh.) P (Press.) 33

35 . W Low Power Solenoid Valves Brass or Stainless Steel Bodies /" to " NPT / 3/ / Low Power Features Moulded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Designed for use in automation of plant control systems to provide: - PLC compatibility - Reduced battery drain - Reduced heat rise - Reduced wiring cost Wide selection includes / normally closed, 3/ normally closed (including Quick Exhaust), 3/ universal, and / Air or inert gas only Lower-cost alternative to intrinsically safe valves in critical applications not requiring a safety barrier Construction Valve Parts in Contact with Fluids Body Brass Stainless Steel Seals and Discs NBR Sleeve 3L Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Pilot Seat Cartridge (Series 836 & 83 only) POM Rider Rings PTFE Spring Retainer POM Electrical Nominal Ambient Temp. Ranges Series Body Material Temperature Range 836/ /8897 Brass & Stainless Steel - F to F (- C to 6 C) 83 Stainless Steel - F to F (- C to 6 C) SPECIAL SERVICE VALVES Ambient Insulation Description Wattage Temp. T Code Class TPL Standard Ambient Version.W F(6 C) T6 F - High Ambient Version.8W 79 F(8 C) T5 F TPL #333 Surge Suppression Version.7W F(6 C) T5 F - Surge Suppression High Ambient Version Description Standard Ambient Version High Ambient Version Surge Suppression Version Surge Suppression High Ambient Version Wattage.W.8W.7W.W.W 79 F(8 C) T5 F TPL #333 Voltage Min. Pull 3way Drop way Drop Coil resistance (DC) In (ma) Out (ma) Out F( C) (ohms) V V V V V V V V V V V V V VDC Spare Coil P/N Standard Ambient Temp. Version High Ambient Temp. Version General Purpose D* D* Explosionproof D* D* Explosionproof, Corrosion Resistant 77-9-D* D* Explosionproof, Surge Suppression D* D* Explosionproof, Corrosion Resistant, Surge Suppression D* D* 836/ / Approvals Stainless Steel -59 F to F (-5 C to 6 C) 837/83: UL listed General Purpose Valves (MP68), CSA certified (38). Meets applicable CE directives. 833/8897, 836 as 5,7596 & : UL listed solenoid (Hazardous Location Classified), CSA certified solenoid only, nonincendive for Class I, Division UL E6 for - F (- C). Meets applicable CE directives. 837/83 with EF/EV Prefix: UL listed (Hazardous Location Classified), Class I, Division UL E559. Certified CSA valve (3976). Meets applicable CE directives. SIL 3 capable per IEC 658 on 836 const. Third party certification provided by EXIDA. Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number. For explosionproof with 36 Stainless Steel hub and trim, specify prefix EV.) Surge suppression coils also available MF prefix. For Optional Features, consult factory. 3

36 / 3/ / Low Power Specifications SPECIAL SERVICE VALVES Pipe Orifice Pressure to Cylinder Cv Flow Factor / VALVES, NORMALLY CLOSED, with NBR Disc Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Brass Body Cylinder to Exhaust Min. Catalogue Number Ref. Stainless Steel Body Catalogue Number / 3/ G3 3/ VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc - SIL 3 Certified by Exida» / 5/6.5.5 ➃ 5 EFX836G3MF/5 ➂ 3 EVX836G38MF/5 ➂ 3 / 5/6.5.5 ➆ - - EVX836G38MB/7596 ➇ 3 / 5/ ➅ - - EVX836G38MB/ ➇ 3 3/8 5/6.6.6 ➃ 5 EFX836G3MF/5 ➂ 3 EVX836G38MF/5 ➂ 3 3/8 5/6.6.6 ➆ - - EVX836G38MB/7596 ➇ 3 3/8 5/ ➅ - - EVX836G38MB/ ➇ 3 3/8 5/8 ƒ 5 EFX836G33MF/5 ➂ 3A - - / 5/8 ƒ 5 EFX836G3MF/5 ➂ 3A EVX836G38MF/5 ➂ 3A 3/ VALVES, UNIVERSAL (Normally Closed or Normally Open) "Quick Exhaust" with NBR Diaphragm and NBR Disc / ➁ G37 ➀ 6 837G38 ➀ 7 / VALVES, Brass Body with NBR Disc Ref. Pipe Orifice Cv Flow Factor Pressure to Cylinder to Cylinder Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Single Solenoid Exhaust Min. Catalogue Number Ref. Dual Solenoid Catalogue Number / / EFX83G37MF/8897 ➀➂ 9 EFX83G3MF/8897 ➂ 3/8 3/8.. 5 EFX83G37MF/8897 ➀➂ EFX83G38MF/8897 ➂ / 3/8.. 5 EFX83G37MF/8897 ➀➂ EFX83G38MF/8897 ➂ 3/ 3/ EFX83G376MF/8897 ➀➂ / EFX83G378MF/8897 ➀➂ ➀ There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to atmosphere. ➁ For "Quick Exhaust" valves, pressure port is /6", exhaust port is /". ➂ IMPORTANT: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➃ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph on page 36 for auxiliary pressure vs. mainline pressure. Minimum psi operating pressure differential when selection gasket is in the internal position. ƒ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph on page 36 for auxiliary pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. ➅ IMPORTANT: Internal Pilot Construction: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➆ IMPORTANT: External Pilot Construction: Zero minimum operating pressure differential when the gasket is in the external position and proper auxiliary air pressure is applied. See graph on page 36 for pilot line pressure vs. mainline pressure. ➇ At -59 F (-5 C), these constructions have a reduced life expectancy. Consult factory for details.» SIL 3 Certified by Exida, only valid when used as Normally Closed. Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. IMPORTANT: Supervisory and leakage current above the drop out current of 7mA for V DC will cause improper operation. Consult your local ASCO sales office for additional assistance. Ref. 35

37 / 3/ / Low Power Dimensions: inches (mm) Ref. 3A Ref SPECIAL SERVICE VALVES Ref. 3 MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION PILOT LINE PRESSURE (psi) MAINLINE PRESSURE (psi) 36

38 / 3/ / Low Power Dimensions: inches (mm) SPECIAL SERVICE VALVES Ref. Dia D E F G H J K L N P W X Y Z 9 ins. Ø mm ins. Ø mm ins. Ø mm ins. Ø mm ins. Ø mm Ref. 9,,,, 3 Exhaust Pipe 3/8 / / 3/8 Ref. 37

39 .55 W Low Power Solenoid Valves Brass or Stainless Steel Bodies /" to /" NPT / 3/ 5/ 5/3 Low Power Features Moulded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard ambient temperature of 9 F (65 C) Optional 76 F (8 C) high ambient temperature version Designed for use in automation of plant control systems to provide: - PLC and DCS compatibility for BUS network and traditional wiring - Reduced temperature rise - Increase battery life - Reduce wiring cost - Energy savings Wide selection includes / normally closed, 3/ universal, 5/, and 5/3 Construction Valve Parts in Contact with Fluids Body Brass Stainless Steel Seals and Discs PUR, NBR, FKM, CR, as listed Sleeve 3L Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Rider Rings PTFE Spring Retainer POM Electrical Description Wattage Ambient Temp. T Code Insulation Class Prefix Standard Ambient Version.55 W 9 F (65 C) T6 F - High Ambient Version.7 W 76 F (8 C) T6 H HT Surge Suppression Version.75 W 9 F (65 C) T6 F MF Description Wattage Standard Ambient Version.55W High Ambient Version.7W Surge Suppression Version.75W Min. Pull In (ma) Drop Out (ma) Coil F ( C) (ohms) Voltage (DC) V V V V** , V V V V** V. 65* V * 8V * 5V** * Note: * Surge suppression contains diode bridge. ** Not for battery applications VDC Spare Coil P/N Standard Ambient Temp. Version High Ambient Temp. Version General Purpose D* D* Explosionproof D* D* Explosionproof, Corrosion Resistant D* D* Explosionproof, Surge Suppression D* Not Available Explosionproof, Corrosion Resistant, Surge Suppression D* Not Available Note: For VDC, 8VDC and 5VDC coil PN consult factory 83 Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number. For explosionproof with 36 Stainless Steel hub and trim, specify prefix EV.) Surge suppression coils also available MF prefix. For Optional Features, consult factory. Approvals UL & CSA Approved for Class I Div. Locations & Class I Div. Nonincendive. UL Listed General Purpose Valves. Meets applicable CE directives. Brass 855 & 8553: UL listed solenoid (Hazardous Location Classified, E6), CSA certified solenoid only (3976), nonincendive for Class I, Division, - F (- C). Meets applicable CE directives. Stainless Steel 855 with EF prefix: UL listed (Hazardous Location Qualified), Class I Division UL E559. Certified CSA valve (3976). Meets applicable CE directives. SIL 3 capable per IEC 658 on 83, 836, 855, and 8553 const. Third party certification provided by EXIDA. 38 SPECIAL SERVICE VALVES

40 / 3/ 5/ 5/3 Low Power SPECIAL SERVICE VALVES Nominal Ambient Temp. Ranges Specifications P ipe Series Body Material Normal Temperature Range High Ambient Temp. Version 8553 Stainless Steel 855 Brass Orifice Cv Flow Factor Pressure to Cylinder to Cylinder - F to F (- C to 6 C) Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Not Available 855 Stainless Steel 83 - F to 9 F (- C to 65 C) Low Limit is the same as Brass / Stainless Steel Normal Temperature Ratings, 837 but High Limit is 76 F (8 C) 836 Stainless Steel -59 F to 9 F (-5 C to 65 C) Brass Body Important These solenoids are intended for use on clean, dry air or inert gas filtered to 5 microns or better. To prevent freezing, the dew point of the media should be at least 8 F (-8 C) below the minimum temperature to which any portion of the clean air or gas system could be exposed. Instrument air in compliance with ANSI/ISA Standard S (R98) exceeds the above requirements and is, therefore, an acceptable medium for these valves. Stainless Steel Body Exhaust Min. Catalogue Number Ref. Catalogue Number Ref. 3/ VALVES, UNIVERSAL OPERATION (Normally Closed or Normally Open) with NBR Disc SIL 3 Certified by Exida ➁ / /.6.6 3/5 9 83H3 83H3 3/ VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc - SIL 3 Certified by Exida ➁ / 5/6.5.5 ➂ EV836H385 ➄ 5 / 5/ EV836H386 ➄ 5 3/8 5/6.6.6 ➂ EV836H387 ➄ 5 3/8 5/ EV835H388 ➄ 5 Normally closed = 3 psi. Normally open = 5 psi. ➁ SIL 3 Certified by Exida, only valid when used as Normally Closed. Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. ➂ IMPORTANT: Internal Pilot Construction: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. IMPORTANT: External Pilot Construction: Zero minimum operating pressure differential when the gasket is in the external position and proper auxiliary air pressure is applied. See graph on page 36 for pilot line pressure vs. mainline pressure. ➄ At -59 F (-5 C), these constructions have a reduced life expectancy. Consult factory for details. IMPORTANT: Supervisory and leakage current above the drop out current of.89 ma for V DC will cause improper operation. Consult your local ASCO sales office for additional assistance. Single Solenoid SIL 3 Certified by Exida Dual Solenoid Body Material Pipe Orifice 3/, 5/ VALVES, with NBR and PUR Seals Brass 3/ Cv Flow Factor Operating Pressure Differential (psi) Air-Inert Gas Operating Pressure Differential (psi) Air-Inert Gas Min. Fluid Temp. F Catalogue Number Ref. Min. EF855H37 ➁ Fluid Temp. F Catalogue Number Brass 5/ EF855H39 ➁ EF855H3 ➁ / /.86 36L Stainless Steel 3/ EV855H33 ➂ EV855H3 ➂ L Stainless Steel 5/ EV855H3 ➂ EV855H3 ➂ Ref. EF855H38 ➁ 36L Stainless Steel 3/ EV8553H33 ➂ EV8553H3 ➂ / / L Stainless Steel 5/ EV8553H3 ➂ EV8553H3 ➂ 3/, 5/, 5/3 VALVES, with NBR and PUR Seals, NAMUR Mount Brass 3/, 5/ EF855H33 ➁ 3 EF855H3 ➁ 3 / /.86 36L Stainless Steel 3/, 5/ EV855H39 ➂ EV855H3 ➂ 36L Stainless Steel 3/, 5/ / / 3.7 EV8553H39 ➂ EV8553H3 ➂ /8" NPT exhaust for /" aluminum and brass. ➁ Brass construction supplied standard with EF solenoid. ➂ Stainless steel construction supplied standard with EV solenoid. SIL 3 Certified by Exida, only valid when used as Normally Closed. Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. 39

41 / 3/ 5/ 5/3 Low Power Dimensions: inches (mm) Ref.,.5 [.3]. [9.56] M5 THREAD n3. MIN FULL THREAD DEPTH.5 `.5 MIN. TAP DRLL DEPTH PLACES.9 [.] / NPT.7 [.7] 3.7 [8.].9 [.] SPECIAL SERVICE VALVES.59 [.5].9 [3.]

42 / 3/ 5/ 5/3 Low Power Dimensions: inches (mm) Series NPT / / L 5. (3) 6. (53) L 6.73 (7) 7.8 (98) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Ref. 3. [77].3 [5] SPECIAL SERVICE VALVES Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H H 3 /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand Series NPT / / L 5.63 () 7.6 (8) L 7. (83) 8.86 (5) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref. 3. [77].3 [5] 5 3 Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand

43 / 3/ 5/ 5/3 Low Power Dimensions: inches (mm) Series 855 (Brass) NPT / L.96 (6) L 6.9 (65) H.38 () H.57 () W.77 (5) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H H Ref [77].3 [5] /8 NPT 3 /8 NPT AUX. PRESSURE PORT / NPT L L 855 NAMUR Footprint SPECIAL SERVICE VALVES MH Momentary push in by hand.6 (3) MS Push and turn to lock by hand.95 ()

44 / 3/ 5/ 5/3 Low Power Dimensions: inches (mm) SPECIAL SERVICE VALVES Series 855 (36L SS) 8553 NPT / / L 5. (3) 7.8 (8) L 6.73 (7) 8.85 (5) H.38 ().77 () H.57 ().8 (53) W.77 (5).87 (73) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Add Suffix MO MI MH MS Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot Momentary push in by hand Push and turn to lock by hand 3. [77].3 [5] (855) / NPT (8553) / NPT H 5 3 H W /8 NPT AUX. PRESSURE PORT L L 8553 NAMUR Footprint 855 NAMUR Footprint Ref..77 (5).95 ().6 (3).57 () Ref [78].6 [5] S.95 [5] / NPT B R Ø8 [7] ( Places) C P H F K A N W M L Catalogue Number A B C F H K L M N P R S W in H3, 3 mm

45 Intrinsically Safe and Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ IS & NIFW Features Available in different coil terminations H Class coil construction Designed solely for installation in intrinsically safe or NIFW areas, with properly approved and sized limiting barriers Compatible with supervisory current applications Mountable in any position F M APPROVED Enclosure Ratings Catalogue Prefix Valve Construction Valve Parts in Contact with Fluids Body Aluminum Brass Stainless Steel Seals and Discs PUR, NBR, FKM as listed Sleeve 3 Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Pilot Seat Insert (Series 836 & 83 only) POM Rider Rings PTFE Spring Retainer POM Electrical Nominal voltage before the barrier VDC +/- %. Maximum Allowable Off State Leakage Current or Supervisory Current.6mA I loop I loop Where: R coil R coil R loop - Loop current in the circuit, which may be calculated as follows: = R barrier V supply V supply (R coil + R loop + R barrier ) - The resistance of the solenoid coil at T ambient in degrees C = 3 ohms x (T ambient + 3) 5 - Resistance of the lead wires - Internal resistance of the barrier - Supply voltage Enclosure Type Rating This current must always be greater than or equal to.3 amps for proper operation of the solenoid valve. Enclosure IP Rating Description 3, 3S IP55 IS /" NPT Conduit, X IP66 6, 6P IP67 JPIS Aluminum Junction Box, X IP66 with /" NPT Conduit 6, 6P IP67 JSIS 36L Stainless Steel Junction Box, X IP66 with /" NPT Conduit 6, 6P IP67 VT 5-Pin (Male M) NA IP ISSC DIN (Form A) NA IP Ordering Information Example: With Junction Box JPIS83B3 With 36L Stainless Steel Junction Box JSIS83B3 With Conduit IS83B3 With Quick Disconnect ISVT83B3 With DIN Connector ISSC83B3 Approvals FM and CSA approved for IS - Class I, Div. &, Groups A, B, C, and D; Class II, Groups E, F, and G. FM approved only for NIFW - Class I, Div. (US only) FM (US & Canada) approved under & C CSA certified under File 3976, Class 38- (C of C 993) ATEX Approved for: II G Ex ia IIC T6 under FMATEX5X IECEx Approved for: Ex ia IIC T6 under IECExFMG.8X Meets applicable CE directives. Refer to Engineering Section for details. Entity Parameters Vmax = 3 VDC Ci = nf Imax = 5 ma Imax = 5 ma Pi =.5 W JPIS/JSIS Nominal Ambient Temp. Range Series Body Material Normal Temperature Range 8553 Stainless Steel 855 Brass - F to F (- C to 6 C) 836/5 Brass / Stainless Steel 855 Stainless Steel 83 - F to 9 F (- C to 65 C) Brass / Stainless Steel /5 836/6 Stainless Steel -59 F to 9 F (-5 C to 65 C) WBIS Nominal Ambient Temp. Range Series Body Material Normal Temperature Range 86 Brass / 83MF Stainless Steel - F to F (- C to 6 C) 83 Stainless Steel - F to F (- C to 6 C) SPECIAL SERVICE VALVES

46 / 3/ / 5/ IS SPECIAL SERVICE VALVES Specifications / VALVES, NORMALLY CLOSED, with NBR Disc Operating Pressure Differential (psi) Pipe Orifice Air-Inert Gas Brass Body Stainless Steel Body Cv Flow Factor Min. Fluid and Ambient Temp. F Catalogue Number Ref. Catalogue Number Ref. / /6.8 5 WBIS86A3 WBIS86A386 A / 3/ WBIS83A3 3 3/ VALVES Cv Flow Factor Pressure to Cylinder to Cylinder Operating Pressure Differential (psi) Pipe Orifice Air-Inert Gas Brass Body Exhaust Min. Fluid and Ambient Temp. F Catalogue Number UNIVERSAL OPERATION (Pressure at any port) with NBR Disc Ref. Stainless Steel Body Catalogue Number / / /5» 9 JPIS83B3 JPIS83B3 A NORMALLY CLOSED (Closed when de-energized) / 5/ JPISX836B3MF/5 ➂ 5 JPISX836B38MF/5 ➂ 8 / 5/ ➅ JPISX836B38/5 ➇ 8 / 5/6.5.5 ➆ JPISX836B38/6 ➇ 8 3/8 5/ JPISX836B3MF/5 ➂ 5 JPISX836B38MF/5 ➂ 8 3/8 5/ ➅ JPISX836B38/5 ➇ 8 3/8 5/6.6.6 ➆ JPISX836B38/6 ➇ 8 3/8 5/8 ➄ 3 9 JPISX836B33MF/5 ➂ / 5/8 ➄ 3 9 JPISX836B3MF/5 ➂ 6 JPISX836B38MF/5 ➂ 9 UNIVERSAL OPERATION (Normally Closed or Normally Open) Quick Exhaust with NBR Diaphragm and NBR Disc / ➁ JPIS837B37 JPIS837B38 / VALVES, Brass Body with NBR Disc Single Solenoid Ref. Dual Solenoid Ref. / / WBIS83A37MF ➂ 3 WBIS83A3MF ➂ 6 3/8 3/8.. 5 WBIS83A37MF ➂ WBIS83A38MF ➂ 7 / 3/8.. 5 WBIS83A37MF ➂ WBIS83A38MF ➂ 7 3/ 3/ WBIS83A376MF ➂ / WBIS83A378MF ➂ There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to the atmosphere. ➁ For Quick Exhaust valves, pressure port is /6", exhaust port is /". ➂ IMPORTANT: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph with dimensional drawings for auxiliary pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. Ref. ➄ At temperatures below 3 F: 5 psi minimum mainline operating differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph with dimensional drawings for auxiliary pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. ➅ IMPORTANT: Internal Pilot Construction: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➆ IMPORTANT: External Pilot Construction: Zero minimum operating pressure differential when the gasket is in the external position and proper auxiliary air pressure is applied. See graph on page 8 for pilot line pressure vs. mainline pressure. ➇ At -59 F (-5 C), these constructions have a reduced life expectancy. Consult factory for details.» Normally closed = 3 psi. Normally open = 5 psi. 5

47 / 3/ / 5/ IS Specifications Body Material Pipe Orifice Cv Flow Factor Single Solenoid Operating Pressure Operating Pressure Differential (psi) Differential (psi) Air-Inert Gas Fluid Catalogue Air-Inert Gas Min. Temp. F Number Ref. Min. Dual Solenoid Fluid Temp. F Catalogue Number 3/, 5/ VALVES, with NBR and PUR Seals Brass 3/ JPIS855B37 9 JPIS855B38 9 Brass 5/ JPIS855B39 JPIS855B3 / / L Stainless Steel 3/ JPIS855B33 9 JPIS855B3 9 36L Stainless Steel 5/ JPIS855B3 JPIS855B3 Ref. Body Material Pipe Orifice Cv Flow Factor Single Solenoid Operating Pressure Operating Pressure Differential (psi) Differential (psi) Air-Inert Gas Fluid Catalogue Air-Inert Gas Min. Temp. F Number Ref. Min. Dual Solenoid Fluid Temp. F Catalogue Number 3/, 5/ VALVES, with NBR and PUR Seals, NAMUR Mount Brass 3/, 5/ JPIS855B33 JPIS855B3 / / L Stainless Steel 3/, 5/ JPIS855B39 JPIS855B3 /8" NPT exhaust for /" aluminum and brass. Ref. SPECIAL SERVICE VALVES Dimensions: inches (mm) Ref., A 6

48 / 3/ / 5/ IS Dimensions: inches (mm) Ref. 3 Ref., A SPECIAL SERVICE VALVES Ref. 5 7

49 / 3/ / 5/ IS Dimensions: inches (mm) Ref. 6 Ref. 8 SPECIAL SERVICE VALVES Ref. 9 Ref. Refer to note ➆. For all 836. MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION PILOT LINE PRESSURE (psi) MAINLINE PRESSURE (psi) 8

50 / 3/ / 5/ IS Dimensions: inches (mm) Ref. SPECIAL SERVICE VALVES Ref All Catalogue No. ØC E F G H J K L M N P W X Y Z WBIS83A37 ins mm WBIS83A38, 38 ins mm WBIS83A37, 37 ins mm WBIS83A3 ins mm WBIS83A376, 378 ins mm IMPORTANT: Valves can be mounted in any position. Exhaust Pipe 3/8" /" /" 3/8" " 9

51 / 3/ / 5/ IS Dimensions: inches (mm) Series NPT / / L 5. (3) 6. (53) L 6.73 (7) 7.8 (98) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref. 9.5 (5) 3.6 (8) / NPT 3.96 (8) 3. (77) Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H /8 NPT AUX. PRESSURE PORT L L SPECIAL SERVICE VALVES MH Momentary push in by hand MS Push and turn to lock by hand Series NPT / / L 5.63 () 7.6 (8) L 7. (83) 8.86 (5) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref..5 (5) 3.6 (8) / NPT (8) 3. (77) Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand 5

52 / 3/ / 5/ IS Dimensions: inches (mm) Series 855 (Aluminum, Brass) NPT / L.96 (6) L 6.9 (65) H.38 () H.57 () W.77 (5) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref..5 (5) 3.6 (8) / NPT.96 (8) 3. (77) SPECIAL SERVICE VALVES Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W 3 H /8 NPT AUX. PRESSURE PORT L L 855 NAMUR Footprint MH Momentary push in by hand.6 (3) MS Push and turn to lock by hand.95 () Series 855 (36L SS) 855 (5/3) 8553 NPT / / / L 5. (3) (8) L 6.73 (7) 7. (89) 8.85 (5) H.38 ().38 ().77 () H.57 ().57 ().8 (53) W.77 (5).77 (5).87 (73) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref..5 (5) 3.6 (8) / NPT (8) 3. (77) Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot H W /8 NPT AUX. PRESSURE PORT L 8553 NAMUR Footprint L 855 NAMUR Footprint MH MS Momentary push in by hand Push and turn to lock by hand.77 (5).95 ().6 (3).57 () 5

53 No Voltage Release Air and Inert Gas Intrinsically Safe Manual Reset Valves Stainless Steel Bodies /" to /" NPT 3/ ISMR Features Intrinsically safe solenoid. When energized, holds the manual reset mechanism in the latched position Normally closed, normally open, or universal constructions Valve operates when the solenoid has been energized and the lever latched while holding in the yellow button Valve trips when power is interrupted. Valve can be manually cycled, but must be manually reset for automatic operation Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting safety barriers Acceptable for use in hazardous locations as classified by the National Electrical Code: Classes I, II, and III, Division, including Groups A through G F M APPROVED SPECIAL SERVICE VALVES Construction Valve Parts in Contact with Fluids Body Seals and Disc Core and Plugnut Core Springs Core Tube Pilot Seat Cartridge Rider Rings Spring Retainer Stainless Steel NBR 3F Stainless Steel 3 Stainless Steel 35 Stainless Steel POM (Series WPIS838C) PTFE POM Electrical Standard Voltages: volts DC Coil: Continuous duty moulded Class A. Minimum Operating Current:. amps Parameters Groups A-D Groups C-D Entity V max - 8 VDC V max - 3 VDC I max - 9 ma I max - 5 ma Capacitance = Capacitance = Inductance = Inductance = IMPORTANT: Electrical parameters are unique to the manual reset line and will differ from other Intrinsically Safe valve s electrical data. Nominal Ambient Temp. Ranges - F to F (- C to 93 C). Approvals FM approved under J. I. 3WA7.AX (36). CSA certified under File LR FM Nonincendive approved for Class, Division. Enclosure Standard: RedHat Type, Watertight Splice Box enclosure. Optional: No standard options are available. Consult local sales office for your needs. 5

54 3/ ISMR Specifications Pipe Orifice Cv Flow Factor 3/ UNIVERSAL OPERATION, Stainless Steel Body with NBR Discs Min. Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Catalogue Number / / WPIS838AMF 3/ UNIVERSAL OPERATION, Stainless Steel Body with Stainless Steel Seats and Discs / 5/ WPIS8387MF 3 For dimensions, consult factory. Ref. SPECIAL SERVICE VALVES 53

55 Tamper Proof Manual Reset Valves Stainless Steel Bodies /", 3/8" and /" NPT 3/ ISMR Features 3 Way constructions -59 F (-5 C) constructions available Low Power or IS with Limit Switch 36SS (CF-8M) Stainless Steel externals with NBR elastomers Wide range of Cv flow rates.5,.8 and Solenoid operator CSA certified, UL Listed for Hazardous Locations Used by numerous refineries as emergency shut down SPECIAL SERVICE VALVES Model shown HV837- VDC Ambient rating -59 F (-5 C) 3 Way Tamper Proof Manual Reset Valve General Description This unique tamper proof manual reset valve has the special ability that once tripped the latching handle, if moved will not change the position of the valve. Conversely, if the handle is held in the up position and the control room de-energizes the solenoid, the valve will go to the shut-off position. It will also automatically trip to the closed position if the auxiliary instrument air pressure drops below 5 psi. 5

56 3/ 5/ NF ATEX Solenoid Valves Brass or Stainless Steel Bodies /" NPT Features ATEX 9/9/EC directive approved Can be used in Zone and Zone hazardous areas Direct acting and indirect acting valves available Available voltages of volts DC and 3 volts, 5 Hz AC All constructions have functional safety data per IEC 658 available SPECIAL SERVICE VALVES Construction Valve Parts in Contact with Fluid Valve Series Body Br or 36 SS 36 SS Core and Plugnut 3F SS Core Tube 33 SS Disc and Seals VMQ PUR & VMQ Rider Ring PTFE Springs 33 SS Series 837 Body Material All Materials 855 SS ATEX Safety Code II G/D Eex d IIC Voltage Min. Ambient Temp. F ( C) T Amb. T F ( C) T Cable T Amb. T5 F ( C) T Cable T Amb. T6 F ( C) T Cable AC () 58 (7) - (-) - DC () 58 (7) AC (6) 9 (9) () 58 (7) 77 (5) 58 (7) - (-) DC - 9 (9) (6) 76 (8) () 58 (7) Solenoid Enclosures Standard: Electrical Enclosure Protection (EN659): Aluminum IP-67 Approvals Directive ATEX 9/9/EC II G/D Eex d IIC T6. T IP67 EC type examination certificate no. LCIE ATEX 68 X 55

57 ATEX Solenoid Valves Brass or Stainless Steel Bodies /" NPT 3/ 5/ NF Specifications 3/ VALVES, UNIVERSAL (Normally Closed or Normally Open), Direct Acting Pipe (ins) Orifice (ins) Cv Flow Factor Operating Pressure Differential (psi) AC Fluid Temp. F Ports - Ports -3 Min. Air-Inert Gas Water Light 3 SSU Air-Inert Gas Water Light 3 SSU AC DC ➁ Catalogue Number Body Material AC DC / / NF837B BR NF837B 36 SS. 3/ VALVES, NORMALLY CLOSED (Closed when de-energized), Indirect Acting Pipe (ins) Orifice (ins) Cv Flow Factor DC Wattage Operating Pressure Differential (psi) Wattage Min. Air-Inert Gas Fluid Temp. F ➁ Catalogue Number Body Material AC DC / / NF855A3 36 SS.5. 5/ VALVES, Indirect Acting Pipe (ins) Orifice (ins) Cv Flow Factor Operating Pressure Differential (psi) Wattage Min. Air-Inert Gas Fluid Temp. F ➁ Catalogue Number Body Material AC DC / / NF855A 36 SS.5. 3/, 5/ NAMUR MOUNT VALVES, Indirect Acting Pipe (ins) Orifice (ins) Cv Flow Factor Operating Pressure Differential (psi) Wattage Min. Air-Inert Gas Fluid Temp. F ➁ Catalogue Number Body Material AC DC / / NF855A9 36 SS.5. SPECIAL SERVICE VALVES Zero minimum when end cap gasket is in external position and proper auxiliary air pressure is applied. Minimum 3 psi Operating Pressure Differential when end cap gasket is in the external position. See I&M sheet for details. ➁ For dimensions, consult factory. 56

58 Accessories Lightweight, High Flow Air Only Quick Exhaust Shuttle Valve Stainless Steel Bodies /" NPT Features Compact, 3-ported valves have oversized orifice for quick exhaust of cylinders, brakes, actuators, clutches, etc. Allow use of smaller pipe lines and control components When used as a shuttle valve, high pressure from the two inlets exits through the common outlet Mountable in any position Construction Valve Parts in Contact with Fluids Body and Bonnet 36 Stainless Steel ACCESSORIES Seat Specifications TEEE Nominal Ambient Temp. Ranges - F to 5 F (- C to 5 C) Pipe Pressure to Cylinder Cv Flow Factor Cylinder to Exhaust Opening Pressure (psi) Maximum Operating Pressure Differential (psi) Air Temp. F Quick Exhaust/ Shuttle Valve Body Material Catalogue Number / V3 5 S.S 3 Ref. Dimensions inches (mm) Ref. 3 Flow Diagrams Inlet Pressure Inlet Pressure Common Outlet Common Outlet Inlet Pressure Inlet Pressure Inlet Pressure Cylinder Cylinder Exhaust 57

59 Optional Explosionproof Junction Box for Hazardous Locations Features Features Junction Box Enclosures for the wiring of ASCO solenoids are Raintight Type 3 and 3S, Watertight Type and X, Submersible Type 6 and 6P, Explosionproof Type 7, Class I, Groups B, C, and D Dust-Ignition proof Type 9, Class II, Div., Groups E, F and G, Nonincendive Class I, Div. (. watts only) Approvals: UL, CSA Electrostatic powder paint, stainless steel screws, and moulded epoxy coils provide excellent protection in corrosion environments Factory pre-wired and assembled to any explosionproof ASCO RedHat II solenoid valve Reduces installation costs by eliminating the need to use a separate explosionproof splice box to terminate the solenoid valve s wiring % ^ Stainless Steel Captive Screws Materials of Construction Housing and Cover Epoxy painted die-cast aluminum Gasket NBR Cover Screws Stainless Steel Coil Epoxy Moulded Ground Screws Steel Terminal Block Plastic Lock Nut Zinc Captive Gasket Electrostatic Powder Painted Aluminum Housing & Cover OPTIONAL FEATURES Electrical Standard Voltages AC:,,, 8 volts, 6 Hz or (, volts, 5 Hz) pt. Terminal Strip Ground Screws Conduit/Cable Connection DC: 6,,,, Note: Valves with JBEF housing maintain wattage and current ratings as shown on individual catalogue sheets. Conduit s Approvals Agency UL CSA /" NPT JBEF Prefix (Standard) 3/" NPT JCEF Prefix (Optional) Explosionproof Junction Box Agency Approvals Temperature Range Gas Groups JBEF (/ ) JCEF (3/ ) Class I, Groups B, C, & D Class I, Group B Class I, Groups C & D - F to 75 F (- C to 8 C) -3 F to 75 F (-5 C to 8 C) - F to 75 F (- C to 8 C) Dust Groups Class II, Groups E, F, & G Ordering Information Add prefix corresponding to specific conduit size required to any RedHat II valve catalogue numbers & specify the voltage. Example: JBEF83H3, VDC. Dimensions Consult factory. 58

60 Canada Main Office, Manufacturing, Marketing 7 Airport Road, P.O. Box 6 Brantford ON N3T 5M8 Phone: (59) Fax: (59) Website: USA Hanover Road Florham Park, NJ 793 Phone: (973) 966- Fax: (973) Website: For Western Provinces Phone: District Sales Offices Canada: Quebec, Ottawa Valley, Atlantic Provinces 3 Douglas. - B. - Floreani St. St. Laurent QC HS Y7 Phone: (5) 33-6 Fax: (5) For Atlantic Provinces Phone: (9) 89-5 Fax: (9) 89-7 Germany Tel (9) Australia Tel (6) United Kingdom Tel () Brazil Tel (55) -8-7 China Tel (85) Mexico Tel (5) Singapore Tel (65) France Tel (33) Japan Tel (8) CAT # LA.R3 5/3

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4 NPT. Features. Construction. Direct Acting Direct Mount Pilot Valves Brass or Stainless Steel Bodies /" NPT / 83 Direct Mount Features NAMUR direct mount version of the rugged, dependable 83 Series valves Direct acting, high flow

More information

3 Way/2 Position Valves

3 Way/2 Position Valves Way/ Position Valves Three way valves have three pipe connections and two orifices. When one orifice is open, the other is closed, and vice versa. They are commonly used to alternately apply pressure to

More information

Constructions Suitable for -40 C to -50 C Ambient

Constructions Suitable for -40 C to -50 C Ambient Constructions Suitable for -40 C to -50 C Ambient 2, 3 and 4 Way Constructions Available Brass and Stainless Steel Bodies Air and Inert Gas Service AIR/INERT GAS QUALITY STATEMENT FOR LOW AMBIENT VALVES

More information

Control & Power, Inc

Control & Power, Inc Way/ 2 and 3 Position Four ported valves are generally used to operate double-acting cylinders or actuators. They have four or five pipe connections, commonly called ports: One pressure inlet. Two cylinder

More information

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4 to 1 NPT. Features .4 W Solenoid Valves Brass or Stainless Steel Bodies /4" to " NPT 4/ Features Moulded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Designed for use in automation

More information

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft) . W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased

More information

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8 to 2 1/2 NPT. Features. Construction. 4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide

More information

2-Way/2 Position Valves

2-Way/2 Position Valves 4 2-Way/2 Position Valves Two-way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply Normally Closed (NC) Fluid is shut off when

More information

Proveedor Integral de Soluciones para la Industria. Desde1963

Proveedor Integral de Soluciones para la Industria. Desde1963 Proveedor Integral de Soluciones para la Industria Desde1963 4 Vías uso general ASCO cuenta con la más amplia gama de válvulas solenoides de usos generales, en 2, 3, 4, y 5 vías, para el manejo de fluidos

More information

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F 4.4 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased

More information

Proveedor Integral de Soluciones para la Industria

Proveedor Integral de Soluciones para la Industria Desde96 Proveedor Integral de Soluciones para la Industria Vías uso general ASCO cuenta con la más amplia gama de válvulas solenoides de usos generales, en,, 4, y 5 vías, para el manejo de fluidos tales

More information

4 N E X T G E N E R A T I O N

4 N E X T G E N E R A T I O N N X T G N R A T I O N lectronically nhanced Solenoid Valves and Stainless Steel Bodies /" - " NPT / 3/ / SRIS Next Generation Features Increase in DC pressure ratings to AC levels on all products (up to

More information

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT Air and Inert Gas Non-Incendive Field Wiring Valves Brass, Aluminum, or Stainless Steel Bodies /" to " NPT / 5/ 5/3 Features solenoid enclosures to provide corrosion resistance in harsh environments Designed

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.55 Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NT / 3/ 4/ 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 low wattage coil Standard ambient

More information

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NT / 3/ / 5/ 5/3 Features Available in different coil terminations H Class coil construction Designed

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT Normally Closed or Normally Open Hot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT 2/2 Features Handle the challenges of high-temperature fluids PTFE and EPDM discs, stainless steel

More information

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical. qwer Normally Closed or Normally Open and Hot Water Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Handle the challenges of high-temperature fluids. PTFE and EPDM discs,

More information

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4 to 3 NPT. 4 qwer High Flow Main Pulse Valves Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT NC 2/2 SERIES Features Specially designed for reverse jet-type dust collector systems. High flow Cv s to 140 for effective

More information

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT ^ % )

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT ^ % ) 888-87-6711 Normally Closed or Normally Open ot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT Features ot water service to 210 psi differential @ 210 F; sevice to 125 psi differential

More information

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F 4.55 Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NT / 3/ 4/ 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 low wattage coil Standard ambient

More information

2/2 ^ % ) Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

2/2 ^ % ) Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8 to 2 1/2 NPT. Features. Construction. 4 ilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" 8210 2-AY Features ide range of pressure ratings, sizes, and resilient materials provide long service life

More information

2/2 3/2 4/2 SERIES Air Operated. General Service Air Operated Valves. Brass Body 1/4" to 2" NPT. Features. Construction.

2/2 3/2 4/2 SERIES Air Operated. General Service Air Operated Valves. Brass Body 1/4 to 2 NPT. Features. Construction. General Service Valves Brass Body 1/" to 2" NPT 2/2 3/2 /2 Features Unique sealing member isolates pilot air pressure from mainline fluid Variations in pilot air pressure do not affect valve operation

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Engineering Design, Plans, and Specifications for an Air-Assisted Filter Backwash System at the Thomas Hill Energy Center Water Treatment Plant

Engineering Design, Plans, and Specifications for an Air-Assisted Filter Backwash System at the Thomas Hill Energy Center Water Treatment Plant Engineering Design, Plans, and Specifications for an Air-Assisted Filter Backwash System at the Thomas Hill Energy Center Water Treatment Plant submitted January, 2009 H2O C Engineering 877-22-WATER www.h2oc.com

More information

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4" to 1" NPT

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4 to 1 NPT 4 Solenoid and Piloted Piston Series Condensate Drain Brass or Stainless Steel Bodies 1/4" to 1" NPT 2/2 Features Designed to automatically drain condensate in compressed air systems Piloted piston assemblies

More information

4 qwer. Air Operated Valves 2/2 3/2 4/2 SERIES. Air Operated. General Service. Brass or Stainless Steel Bodies 1/4" to 2" NPT. Features.

4 qwer. Air Operated Valves 2/2 3/2 4/2 SERIES. Air Operated. General Service. Brass or Stainless Steel Bodies 1/4 to 2 NPT. Features. qwer General Service Valves Brass or Stainless Steel Bodies 1/" to 2" NPT 2/2 3/2 /2 SERIES Features Unique sealing member isolates pilot air pressure from mainline fluid. Variations in pilot air pressure

More information

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1 SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1 NC 2/2 Series 220 FEATURES Small compact d valves particularly designed for hot water and steam, compatible with the seal materials

More information

深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4.

深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4. SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, / / Series FEATURES The monostable spool valves, series, have TÜV certifi ed IEC 60 Functional

More information

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 U 2 1 3 3/2 Series 327 FEATURES The valves are certified according to IEC 61508 Functional Safety data and have SIL-3 capability

More information

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2) Installation & Maintenance Instructions -- WAY DIRECT-- ACTING SOLENOID VALVES REVISION H & R NORMALLY OPEN OR NORMALLY CLOSED OPERATION BRASS OR STAINLESS STEEL CONSTRUCTION -- 1/8I, 1/4I, OR3/8I PIPE

More information

Asia Pacific Express Catalog

Asia Pacific Express Catalog Asia Pacific Express Catalog TABLE OF CONTENTS Page 110 :... 2 210 :...3 215 :...5 220 :...6 223 :...7 238 :...8 256 :...9 262 :...10 X282 :...11 284 :...12 291 :...13 292 :...14 353 :...15 356 :...16

More information

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D..65 to 9.5 mm U / Series 84 FEATURES Solenoid valve suitable for cutting off the flow of a fluid by pinch For sterile, aseptic, physiological

More information

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Quic-Pics Catalogue Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Contents: Product Line Overviews 2 Manually Operated Valves 5 Pushbuttons 6 Toggle Switch 8 Knob

More information

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

DIRECT OPERATED SOLENOID PILOT VALVES Product Index DIRECT OPERATED SOLENOID PILOT VALVES Product Index ports/positions Function pipe connections * - instant fittings O.D. (mm) w - internal thread (ØG) x - external thread (ØG) n - pad mount : - pad mount,

More information

Over 2000 of today's most popular products

Over 2000 of today's most popular products Over 2000 of today's most popular products www.ascovalve.com Table of Contents General Service 2-Way Normally Closed 1-6 2-Way Normally Open 7 2-Way Slow Closing 10 3-Way Normally Closed 11-1 3-Way Normally

More information

Valve Reference C5. Valve Reference C6. 4-Way. 4-way direct acting

Valve Reference C5. Valve Reference C6. 4-Way. 4-way direct acting Valve Reference C5.86 3.25.53 1.31 1.62 E 3.25 4.31 2.37 2.56 1.73 2.24 P 1/4 Thru Bolt Holes 4 PLC s 2.69 4-way direct acting V933xx: Normally Closed-Normally Closed v935xx: Normally Closed-Normally Open

More information

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, / 0 0 /-/ Série FEATURES The monostable spool valves have TÜV certified IEC 608 Functional

More information

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2 POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2 NC 2/2 Series 353 X003GB2009/R8 EATURES The piston cartridge pulse valves are especially designed for

More information

GUARANTEED SAME DAY SHIPMENT General Service - 2/2 NC 1/" Kit Coil Weight (ins.) (ins.) Flow Min. Air Water Oil Temp. F Number Material Material Volta

GUARANTEED SAME DAY SHIPMENT General Service - 2/2 NC 1/ Kit Coil Weight (ins.) (ins.) Flow Min. Air Water Oil Temp. F Number Material Material Volta GUARANTEED SAME DAY SHIPMENT Two way (2/2) general service solenoid valves have one inlet port and one outlet port. Control of air, water, light oil, non-corrosive media Normally Closed (opens when energized)

More information

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472 Data sheet 2-way solenoid valves with Clip-on coils for neutral liquids and gases January 200 DKACV.PD.200.K.22 520B472 2 DKACV.PD.200.K.22 Danfoss A/S 0-200 Contents 2-way solenoid valves with Clip-on

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

Solenoid Valves. Options/Accessories - ASCO offers a wide variety of accessories and optional features to meet your specific application requirements.

Solenoid Valves. Options/Accessories - ASCO offers a wide variety of accessories and optional features to meet your specific application requirements. Solenoid Valves The solenoid is an electromagnetic part of a valve, comprised of a coil, coretube, core and enclosure. ASCO Redhat brand offers the worlds largest selection of 2-, 3- and 4-way solenoid

More information

ACCESSORIES FOR AIR VALVES & AIR SYSTEMS

ACCESSORIES FOR AIR VALVES & AIR SYSTEMS ACCESSORIES FOR AIR VALVES & AIR SYSTEMS BULLETIN ACC-2000R AIR VALVES FOR INDUSTRY SINCE 1949 ISO 9001 CERTIFIED FOOT GUARDS Page 8 QUICK EXHAUST & ELECTRIC QUICK EXHAUST VALVES Pages 6 & 7 SHUTTLE VALVES

More information

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15 MINI-SOLENOID VALVES ISO 58 (CNOMO, size 5) interface direct operated, pad mounting body connector size 5 NC / Series 0 FEATURES Compact, monobloc solenoid pilot valve with spade-plug connector type EN

More information

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT FEATURES Compact design, high fl ow rates Visual position indicator standard For temperatures from 22 F to +430 F / -30 C to 221 C Working pressures up

More information

Miniature Multimedia Valves

Miniature Multimedia Valves 2 Inert Isolation PTFE 3-Way Solenoid Valve Series 1 The Series 1 diaphragm type valve has a low internal volume and rapid response time, which enables users to get readings quickly for their analysis.

More information

4 Series 298 Air Operated Stainless Steel Piston Valves For Steam and Aggressive Fluid Service

4 Series 298 Air Operated Stainless Steel Piston Valves For Steam and Aggressive Fluid Service Series 98 Air Operated Steel Piston Valves For Steam and Aggressive Fluid Service Applications Rubber Vulcanization/Tire Presses Industrial Autoclaves Foundries Laundry Food & Beverage Chemical Processing

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 3/2-way Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2 W 142 = 24 V DC, 4.2 W 152 = 24 V AC, 7/4 VA 156 = 115 V AC,

More information

SKINNER Intrinsically Safe Series Four-Way

SKINNER Intrinsically Safe Series Four-Way SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air

More information

MINIATURE SOLENOID GENERAL SERVICE VALVES

MINIATURE SOLENOID GENERAL SERVICE VALVES MINIATURE SOLENOID GENERAL SERVICE VALVES SERIES The Series solenoid valves are designed for use with air and inert gases Highly customizable construction that is suitable for a wide variety of gas applications

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

An example of an ASCO valve catalog number with prefixes and suffixes: EF HT 8210 G 002 V MO. Construction Features. Number

An example of an ASCO valve catalog number with prefixes and suffixes: EF HT 8210 G 002 V MO. Construction Features. Number 4 Optional Features How to Select and Specify Not all optional features are appropriate or available for all valves. Table 1 lists the optional electrical feature prefixes available for each RedHat II

More information

LIMIT SWITCH Axiom - AX

LIMIT SWITCH Axiom - AX LIMIT SWITCH Axiom - AX with SST Switching Sensors Installation, Maintenance and Operating Instructions (AX33 ) Publication# 10532revB 2 Table of Contents Publication# 10532revB Table Of Contents... Page

More information

Condensate Drain Valve Assemblies

Condensate Drain Valve Assemblies 4 Condensate Drain Valve Assemblies 2-way normally closed operation Compact design Adjustable timers with status indication www.ascovalve.com 1 4 Condensate Drain Valve Assemblies Compressed air is used

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2) ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2) BRASS OR STAINLESS STEEL BODY POLYMER OR METAL ACTUATOR HERION USA Inc. Valve Technology and Systems Brochure N-285 Multi-Accessory Polymer Head versions Increased

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

WELCOME TO MAGNATROL

WELCOME TO MAGNATROL Catalog 6 BULLETIN 6-INDEX WELCOME TO MAGNATROL Process Control Solenoid Valves For Water Oil Air Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936

More information

Direct-acting 2/2-way plunger valve

Direct-acting 2/2-way plunger valve Direct-acting 2/2-way plunger valve Type can be combined with Direct-acting and compact valve up to diameter of DN 6.0 Vibration-proof, bolted coil system Increased leak-tightness with welded plunger guiding

More information

Motorised Valve Range

Motorised Valve Range Motorised Valve Range Contents Motorised Valves... 2 Fail Safe Motorised Valves for Bio Diesel and Bio Fuels... 2 Fail Safe Motorised Valves... 3 Motor-Open Motor-Close... 6 Electro-Thermal Links... 9

More information

Glove Box Instrumentation Specifications

Glove Box Instrumentation Specifications Glove Box Instrumentation Specifications April 11, 2006 The following is a brief list of the major technical specifications of the instrumentation for the Glove Box (GB). The spec sheets for the various

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2

More information

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c The 188 is a 3 Way, 10 mm wide micro solenoid valve designed to be used in fluid power applications. Using air or other neutral gasses the 188 can be used to pilot other valves or cylinders. ompact manifold

More information

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them

More information

Redundant Control System

Redundant Control System Redundant Control System Safety instrumented system applications up to SIL 3 Process reliability Process valve diagnostics COMPLETE FUNCTIONAL SAFETY WITH ENHANCED RELIABILITY The Redundant Control System

More information

Electronic Control Valves

Electronic Control Valves MODEL 131 Series (Full Internal Port) 631 Series (Reduced Internal Port) Electronic Control Valves Model 131-01/631-01 Simple Proven Design Quality Solenoid Pilot Controls Ideal For SCADA Systems Multi-Function

More information

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated > > Port size: G/8 & G/4 > > Low and high power solenoid coil options > > End, side or face mounting solenoids > > Light weight corrosion resistant materials > > Option for manual override acting directly

More information

SOLENOID CONTROL VALVE

SOLENOID CONTROL VALVE PROJECT NAME LOCATION SOLENOID CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 4 in. (100 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard

More information

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2 SOLENOI VLVES no voltage release (lever type) manual reset construction 1/4 to 1/2 U 1 3 2 3/2 Series 307 FETURES Lever type Manual Reset function which means that the valve has to be energized as well

More information

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE PROJECT NAME LOCATION COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900

More information

Customized Solutions. Safety & Reliability Stainless steel 316 products

Customized Solutions. Safety & Reliability Stainless steel 316 products Customized Solutions Safety & Reliability Stainless steel 316 products REDUNDANT CONTROL SYSTEM (RCS) Applications Emergency Shutdown Systems Burner Management Systems Isolation and Venting Systems High

More information

PROCESS & AUTOMATED VALVES

PROCESS & AUTOMATED VALVES Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline

More information

Hazardous Location Solutions for the Process Control Industry. UL CSA FM ATEX IECEx NEPSI INMETRO TR CU

Hazardous Location Solutions for the Process Control Industry. UL CSA FM ATEX IECEx NEPSI INMETRO TR CU 4 Hazardous Location Solutions for the Process Control Industry UL CSA FM ATEX IECEx NEPSI INMETRO TR CU w w w. a s c o v a l v e. c o m ^ # % Global Approvals Fluid automation equipment must operate flawlessly

More information

Transmitters: Relay Valve

Transmitters: Relay Valve Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications

More information

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated ICOS - /, / or 5/ Exia poppet valves > > Port size: /... / (ISO G/NPT) /... (Flanged) > > Zone 0, Exia solenoid pilot operated valve > > Safety integrity level and > > Reliable and long life, ideal for

More information

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT SERIES Features Spring Return or Double Acting Actuators Lead Free Brass Ball Valve with ISO5211 direct mounting Full port design

More information

AIR RIDE SUSPENSION SYSTEMS

AIR RIDE SUSPENSION SYSTEMS AIR RIDE SUSPENSION SYSTEMS Solenoid Valves (Fast Valves) Valve Manifold Systems Pressure Switches Filters (Water Traps) Air Bellows & Fittings www.asconumatics.com 1 ASCO Numatics Air Ride Components

More information

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4 SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 NC 0 0 / Series 55 FEATURES The monostable spool valves have TÜV certified IEC 6508

More information

2/2-way Solenoid Valve for liquids and gases

2/2-way Solenoid Valve for liquids and gases 2/2-way Solenoid Valve for liquids and gases Type 6213EV can be combined with... Coupled spring diaphragm system opened without differential pressure Waterhammer free and low noise HP00 version with increased

More information

Direct-acting 2/2- or 3/2-way pivoted armature valve

Direct-acting 2/2- or 3/2-way pivoted armature valve 0330 Direct-acting 2/2- or 3/2-way pivoted armature valve Direct-acting, media-separated valve with diameter of up to DN 5 Maintenance-free pivoted armature technology Vibration-proof, block screwed coil

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance AUTOMATIC FLOW CONTROL VALVE INSTRUCTIONS Installation - Operation - Inspection - Maintenance 4" - 36" ROSS MODEL - 42AFCV FIGURE 14A Serial #L AUTOMATIC FLOW CONTROL VALVE GLOBE FLAT SEAT STYLE ROSS VALVE

More information

Solenoid Valves Catalogue

Solenoid Valves Catalogue Solenoid Valves Catalogue lcon Solenoid Valve Range US Keeping the World Flowing Contents Section Page Section Page Introduction 3 U Series 4 U Series Exd 6 U3/U33 Series 8 U3/U33 Series Exd 0 68 Series

More information

LIMIT SWITCH Axiom - AX

LIMIT SWITCH Axiom - AX LIMIT SWITCH Axiom - AX with AS-Interface (Standard Addressing) Installation, Maintenance and Operating Instructions (AX9 ) 2 Table of Contents Table Of Contents... Page 2 Axiom Model Guide... Page 3 Dimensions

More information

2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam

2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam cryogenic extended stem 2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam Type 2000 can be combined with Spring return closed or open, double-acting, manual operation Materials:

More information

3-Way. Direct Acting & Pilot Operated Quick Exhaust Valves 1/4" - 3/8" NPT. General Description: Applications: Electrical Characteristics:

3-Way. Direct Acting & Pilot Operated Quick Exhaust Valves 1/4 - 3/8 NPT. General Description: Applications: Electrical Characteristics: Direct Acting & Pilot Operated Quick Exhaust Valves 1/4" - 3/8" General Description: Direct Acting & Pilot Operated Quick Exhaust Valves are designed to provide a large orifice for quick exhaust. Increased

More information

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE FEATURES The bronze ZEUS valve is intended for the automatic shutoff of networks of fluids. The full-bore inclined-seat body and the excellent flow-rate coefficients allow for very low pressure drops.

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

Control Valve Specifications

Control Valve Specifications Control Valve Specifications Available in two-way, three-way and four-way configuration and with port sizes from 10-32UNF through to 1/2"NPT. The N2V & N3V1 offering is a direct acting solenoid poppet

More information

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4 SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 4 2 5 4 2 5 4 2 5 4 2 5 5/2 Series 55 FEATURES The monostable spool valves have TÜV certified

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC SPECIFICATIONS 2-WAY 3-WAY EXPLOSION PROOF VALVES OPERATG CONDITIONS Media: Air, water, and other fluids, compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline inline hazardous location Manifold mounting 35 sub-base non plug-in sub-base with pressure regulators sub-base hazardous

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For

More information

Control Valve Specifications

Control Valve Specifications Control Valve Specifications Available in two-way, three-way and four-way configuration and with port sizes from 10-32UNF through to 1/2"NPT. The N2V & N3V1 offering is a direct acting solenoid poppet

More information

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port. Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 00 Phone 76-559-077 Fax 76-559-0547 Features Single stem design Compact size Four input options Numerous porting configurations Fully ported

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information