1 Solenoid Valves Catalogue lcon Solenoid Valve Range US Keeping the World Flowing

2 Contents Section Page Section Page Introduction 3 U Series 4 U Series Exd 6 U3/U33 Series 8 U3/U33 Series Exd 0 68 Series (Cryogenic) UCD 4 UCD Exd 6 UCDN 8 UCDN Exd 0 UCP UCP Exd 4 UCPX (Steam) 6 UGB 8 Namur 30 Namur Exd, Exia 3 Conversions 34 Corrosion Reference Guide 3 Viscosity Reference Guide 37 Copper winding classification 38 Metals 39 Modes of Operation 40 Protection Class, IP ratings and Hazardous reas 4 Sealing Solutions 43 Solenoid Enclosures 44 Rotork is the global market leader in valve automation and flow control. Our products and services are helping organisations around the world to improve efficiency, assure safety and protect the environment. We strive always for technical excellence, innovation and the highest quality standards in everything we do. s a result, our people and products remain at the forefront of flow control technology. Uncompromising reliability is a feature of our entire product range, from our flagship electric actuator range through to our pneumatic, hydraulic and electro-hydraulic actuators, as well as instruments, gearboxes and valve accessories. Rotork is committed to providing first class support to each client throughout the whole life of their plant, from initial site surveys to installation, maintenance, audits and repair. From our network of national and international offices, our engineers work around the clock to maintain our position of trust. Rotork. Keeping the world flowing.

3 Introduction lcon, a brand of Rotork Midland, designs and manufactures general purpose, specialty and customized solenoid valves and components in a wide variety of materials and configurations to meet a broad range of applications. These valves can be found in oil and gas, industrial process, potable water control, HVC, automotive aftermarket, irrigation, industrial equipment and other industries and are available through a network of stocking distributors and factory direct sales managers. lcon has manufacturing facilities in North merica and Europe and global direct sales and distribution coverage. These facilities are fully integrated with Lean and Six Sigma practices and employ best-in-class engineering and system design capabilities. In the following pages, you will find an extensive selection of our standard product lines. If your application requires customization, please contact your direct sales representative or our factory. ir Water Potable Water Steam Cryogenics Gases Oil & Fuel ctuation Hazardous rea ggressive Media Selection chart Series ir Water Potable Water Gas Oil & Fuel Steam Cryogenics ctuation Hazardous rea Operating Pressure Differential Range (psi) CV Range / (Normally Closed) U (¼ ) UCD ( 3 /8 to ) UCP (½ to ) UGB (¼ to ) UCPX (½ to ) (¼ to ) / (Normally Open) CDN ( 3 /8 to ) / (Normally Closed) U3 (¼ ) / Universal U33 (¼ ) / - / NMUR NMUR (¼ ) lcon maintains the highest certifications on all relevant product lines. These certifications include UL and CS. The icons will designate the certifications of each valve series on the following pages. Canadian Standards ssociation Underwriters Laboratory, Inc. Keeping the World Flowing 3

4 U Series / Normally Closed Mode of Operation Maximum Viscosity Body Material Flange Tube Plunger and top stop Springs Seal Material Connection Type Shading Ring Specifications Normally Closed, energise to open Out () In () SSU Brass or option Nitrile (BunaN) (Std) other options available NPT Copper (std), Silver (stainless steel option) Features and Benefits Direct cting Compact valve design Zero pressure rated Wide range of available Orifices Choice of valve body material and seals Exd options (see separate datasheet) Suitable for vacuum applications when fitted with Viton seals Response time - ms Electrical Characteristics Coil Voltage DC (=) V, 4 V Coil Voltage C 60 Hz (~) 4 V, 0 V Voltage Tolerance +0% or -0% Port Size Cv Kv C OPD (psi) DC P. Max psi Orifice (mm) Weight (lbs) Duty Cycle 00% ED ¼ Electrical Connection Coil Insulation ½ NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H ¼ ¼ ¼ ¼ Power Rating 4. Watts ¼ Options vailable EExd T6 (NEM 6 equivalent) EExd T4 (NEM 6 equivalent) Solenoid Enclosure Protection Class See separate datasheet See corrosion reference guide and sealing solutions for material compatability. Seal Material and Media Temp. Range mbient Temperature Range Min Max Nitrile (4 ºF to +76 ºF) 4 ºF ºF EPDM (-8 ºF to 48 ºF) 4 ºF ºF Viton (-4 ºF to +30 ºF) 4 ºF ºF PTFE (-38 ºF to +36 ºF) 4 ºF ºF Main valve body options 36 Manual Override Tagging (consult factory for product code) Pressure Drop (Bar) &. mm orifice.4 mm orifice 4. mm orifice 3.0 mm orifice 6.0 mm orifice 0 0. Pressure Drop (PSI) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model

5 U Series / Normally Closed 3" Coil Rotation 360º Preferred Valve Mounting Options 3 /8" 3 /4" 3 /4" Dimensions given in inches Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Size Connection Type Operation Orifice (mm) Body Material Seals Style Enclosure Type Voltage / Frequency Electrical connection pproval U Series B ¼ 3 NPT UTO MNUL OVERIDE B. C.6 E.4 F 3.0 H 4. Brass 36 Stainless Steel B C E Nitrile EPDM VITON PTFE Standard S4 type enclosure -metal can (IP0) UL pproved F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT UL/CS J 6.0 B 3-9 Product coding example: B3B-H9: Series /4 NPT, uto,. mm orifice, Brass body, Nitrile seals, 0 V / 60 Hz, / NPT electrical connection UL/CS approval Keeping the World Flowing

6 U Series Exd / Normally Closed Specifications Normally Closed, energise to open Out () Mode of Operation In () Maximum Viscosity SSU Body Material Brass or option Flange Tube Plunger and top stop Springs Seal Material Nitrile (BunaN) (Std) other options available Connection Type NPT Shading Ring Copper (std), Silver (stainless steel option) Electrical Characteristics Features and Benefits Compact valve design Zero pressure rated Wide range of available orifices Choice of valve body material and seals Choice of electrical connections TEX approved Response time - ms Tested in accordance with BS-EN 66- Coil Voltage DC (=) Coil Voltage C 60 Hz (~) V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Protection Class (Exd) Electrical Connection (Exd) Coil Insulation Power Rating 00% ED II G Ex d IIC T4 Tamb (-8 F to +8 F) II G Ex d IIC T6 Tamb (-8 F to +04 F) Class Zone Groups II, IIB, IIC gases ½ NPT Port (Std) Class H 4. Watts Port size Cv Kv C OPD (psi) DC P. Max psi Orifice (mm) Protection Class ¼ Exd T6 ¼ Exd T6 ¼ Exd T6 ¼ Exd T6 ¼ Exd T6 ¼ Exd T6 Weight (lbs) excluding solenoid 0.8 Options vailable Protection Class Exd T4 (NEM 6 equivalent) Exd T6 (NEM 6 equivalent) Solenoid Enclosure Electrical Entry ½ NPT conduit (std) M0 X. conduit (option) See corrosion reference guide and sealing solutions for material compatability. Enclosure Material luminium (Std) optional Seal Material and Media Temp. Range mbient Temperature Range Min Max (T6) Max (T4) Nitrile (4 ºF to +76 ºF) 4 ºF 04 ºF 8 ºF EPDM (-8 ºF to +48 ºF) -8 ºF 04 ºF 8 ºF Viton (-4 ºF to +30 ºF) -4 ºF 04 ºF 8 ºF PTFE (-38 ºF to +36 ºF) -8 ºF 04 ºF 8 ºF Main valve body options 36 Manual Override Tagging (consult factory for product code) Pressure Drop (Bar) &. mm orifice.4 mm orifice 4. mm orifice 3.0 mm orifice 6.0 mm orifice 0 0. Pressure Drop (PSI) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model

7 U Series Exd / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options 4 /64" 3 /64 /" NPT (std) conduit entry 4 /6" 4 /64" Exd luminium enclosure as standard 47 /64" Dimensions given in inches Solenoid enclosures Exd S4 type enclosure Power consumption: External material: Electrical entry: Holding 9 V, V to 30 V 0 / 60 Hz. 4. W, V to VDC Powder coated aluminium or 36 st.st. enclosure with st.st. nameplate M0 x. or / NPT conduit entry Protection Class: II G Exd IIC T6 for ambient temp -8 F to +04 F Optional: II G Exd IIC T4 for ambient temp -8 F to +8 F Weight:.8 lbs luminium or 3.3 lbs - CS approval lcon flame proof enclosures are suitable for the following areas / gases: Zones & Class Division Class Division Groups: II, IIB, IIC gases Main Valve ssembly Coil options Model Size Connection Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection T Rating pproval U Series B ¼ 3 NPT UTO MNUL OVERIDE B. C.6 E.4 F 3.0 H 4. Brass 36 Stainless Steel B C E Nitrile EPDM VITON PTFE 3 Exd 6 Exd luminium Exd Stainless Steel F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz M0x. 9 / NPT 9 tex T6 949 tex T4 G (CS) J 6.0 B G Product coding example: B3E3-H99G: Series ¼ NPT, uto,.4 mm orifice, brass body, nitrile seals, Exd luminium housing 0 V / 60 Hz, / NPT electrical connection, T6 CS approved. Keeping the World Flowing 7

8 U3/U33 Series 3/ Normally Closed / Universal Mode of Operation Maximum Viscosity Body Material Flange Tube Plunger and top stop Springs Seal Material Connection Type Shading Ring Specifications 3 series 3/ Normally Closed 33 series 3/ Universal SSU Brass or option Nitrile (BunaN) (Std) other options available NPT Copper (std), Silver (stainless steel option) Features and Benefits Direct acting For mixing, diverting and venting applications Compact valve design Wide range of available orifices Zero Pressure Rated choice of valve body material and seals Exd options (see separate datasheet) Response time - ms Tested in accordance with BS EN 66- Electrical Characteristics Coil Voltage DC (=) Coil Voltage C 60 Hz (~) V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Electrical Connection 00% ED / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Port size Cv Kv C OPD (psi) DC ¼ P. Max psi Orifice (mm).6 Weight Desc. N/C Coil Insulation Power Rating Options vailable Class H 4. Watts ¼ N/C ¼ N/C ¼ Universal ¼ Universal ¼ Universal EExd T6 (NEM 6 equivalent) EExd T4 (NEM 6 equivalent) Solenoid Enclosure Protection Class See separate datasheet Seal Material and Media Temp. Range mbient Temperature Range Min Max Nitrile (4 ºF to +76 ºF) 4 ºF ºF EPDM (-8 ºF to +48 ºF) 4 ºF ºF Viton (-4 ºF to +30 ºF) 4 ºF ºF Main valve body options 36 Manual Override Tagging (consult factory for product code) See corrosion reference guide and sealing solutions for material compatability Pressure Drop (Bar) 0..6 mm orifice.4 mm orifice 3.0 mm orifice Pressure Drop (PSI) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model

9 U3/U33 Series 3/ Normally Closed / Universal Coil Rotation Preferred Valve Mounting Options 360º 3" 3 9 /6" 3 /6" 3 /4" Dimensions given in inches Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Size Connection Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval 9 3 Series 3 33 Series B ¼ 3 NPT UTO MNUL OVERIDE C.6 E.4 F 3.0 Brass 36 Stainless Steel B C Nitrile EPDM VITON Standard S4 type enclosure -metal can (IP0) UL pproved F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT UL/CS B 3-9 Product coding example: 9B3C-H9: 3 Series /4 NPT, uto,.6mm orifice, Brass body, Nitrile seals, 0 V / 60 Hz, / NPT electrical connection UL/CS approval Keeping the World Flowing 9

10 U3/U33 Series Exd 3/ Normally Closed / Universal Specifications 3 series 3/ Normally Closed 3 Mode of Operation 3 33 series 3/ Universal Maximum Viscosity SSU Body Material Brass or option Flange Tube Plunger and top stop Springs Seal Material Nitrile (BunaN) (Std) other options available Connection Type NPT Shading Ring Copper (std), Silver (stainless steel option) Electrical Characteristics Features and Benefits Direct cting Zero pressure rated Compact Valve Design Ideal for mixing, diverting and venting applications Choice of valve body material and seals Wide range of available orifices Response time - ms Tested in accordance with BS-EN 66- Coil Voltage DC (=) Coil Voltage C 0 Hz (~) V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Protection Class (Exd) Electrical Connection (Exd) Coil Insulation Power Rating 00% ED II G Ex d IIC T4 Tamb (-8 F to + 8 F) II G Ex d IIC T6 Tamb (-8 F to + 04 F) Class Zone Groups II, IIB, IIC gases ½ NPT Port (Std) Class H 4. Watts Port Size Cv Kv C OPD (psi) DC ¼ P. Max psi Orifice (mm) Weight (lbs) excluding solenoid Desc. ¼ N/C ¼ N/C ¼ Universal ¼ Universal ¼ Universal.6 N/C Options vailable Protection Class Exd T4 Exd T6 Solenoid Enclosure Electrical Entry ½ NPT conduit (std) M0 X. conduit (option) Enclosure Material luminium (Std) optional Seal Material and Media Temp. Range mbient Temperature Range Min Max (T6) Max (T4) Nitrile (4 ºF to +76 ºF) 4 ºF 04 ºF 8 ºF EPDM (-8 ºF to +48 ºF) -8 ºF 04 ºF 8 ºF Viton (-4 ºF to +30 ºF) -4 ºF 04 ºF 8 ºF Main valve body options 36 Manual Override Tagging (consult factory for product code) See corrosion reference guide and sealing solutions for material compatability Pressure Drop (Bar) 0..6 mm orifice.4 mm orifice 3.0 mm orifice Pressure Drop (PSI) How to use the flow chart Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model

11 U3/U33 Series Exd 3/ Normally Closed / Universal Coil Rotation 360º Preferred Valve Mounting Options 4 /64" 9 /3 37 /64 /64" /3 3 /64" 3 /64" 47 /64" Dimensions given in inches Solenoid enclosures Exd S4 type enclosure Power consumption: External material: Electrical entry: Holding 9 V, V to 30 V 0 / 60 Hz. 4. W, V to VDC Powder coated aluminium or 36 st.st. enclosure with st.st. nameplate M0 x. or / NPT conduit entry Protection Class: II G Exd IIC T6 for ambient temp -8 F to +04 F Optional: II G Exd IIC T4 for ambient temp -8 F to +8 F Weight:.8 lbs luminium or 3.3 lbs - CS approval lcon flame proof enclosures are suitable for the following areas / gases: Zones & Class Division Class Division Groups: II, IIB, IIC gases Main Valve ssembly Coil options Model Size Connection Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection T Rating pproval 9 3 Series 3 33 Series B ¼ 3 NPT UTO MNUL OVERIDE C.6 E.4 F 3.0 Brass 36 Stainless Steel B C Nitrile EPDM VITON 3 Exd 9 3 way Exd luminium 3 way Exd Stainless Steel F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz M0x. 9 / NPT 9 tex T6 949 tex T4 G (CS) B G Product coding example: 9B3E3-9H99G: 3 Series ¼ NPT, uto,.4 mm orifice, brass body, nitrile seals, Exd luminium housing, 0 V / 60Hz, / NPT electrical connection, T6 CS approved. Keeping the World Flowing

12 68 Series: Cryogenic / Normally Closed Mode of Operation Special Features Maximum Viscosity ¼" to " Body Material Flange Tube Plunger and top stop Springs Seal Material Connection Type Specifications Normally Closed, energise to open Out () In () Oxygen degreased and individually packed for use with liquids down to -3 F 6 cst Brass (Std) or option ¼" to " Body Material Bronze PTFE (Teflon) NPT Features and Benefits Controls Cryogenic Media down to -3 ºF Degreased and individually Packaged for Cryogenic Service Larger Porting for High Kv Teflon - PTFE seals Choice of Brass or Stainless steel valve body Tested in accordance with BS-EN 66- Coil Voltage DC (=) Coil Voltage C 60 Hz (~) Electrical Characteristics V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Electrical Connection 00% ED /" NPT metal conduit hub with 8" leads (NEM equivalent protection class) Port size Cv Kv C OPD (psi) DC P. Max psi Orifice (mm) ¼ ¼ / ½ Weight (lbs).8 Coil Insulation Power Rating Class H 4. Watts ¾ ¼ ½ Options vailable EExd T6 EExd T4 Solenoid Enclosure Protection Class Consult Rotork Midland for product codes Seal Material and Media Temp. Range mbient Temperature Range Min Max PTFE (-38 ºF to +36 ºF) 4 ºF ºF See corrosion reference guide and sealing solutions for material compatability. Main valve body options 36 Tagging (consult factory for product code) Water Flow (GPM) Pressure Drop (Bar) 4. mm orifice 6.0 mm orifice 6.0 mm orifice 6.0 mm orifice.0 mm orifice 6.0 mm orifice mm orifice Pressure Drop (PSI) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model Water Flow (L/Min). 000

13 68 Series: Cryogenic / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options C D B Port size B C D ¼ 3 /4 3 /4 9 /6" 3 /6" 3 /8-3 /4 / 4 /8" /6" 4 3 /6" 4 7 /6" 4 /6" 3 /6" 3 /4 ¼ -½ 4 /8" ¼ 7 /8" 7 /6" " 3 /4" /6" 3 3 /4" 8 /4" Dimensions given in inches Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Valve Body Conn. Size Connection Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval series B ¼ C 3 /8 D ½ E ¾ F G ¼ H ½ J 3 NPT UTO H 4. J 6.0 Z Default Brass (standard on valves up to and including Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) E PTFE Standard S4 type enclosure -metal can (IP0) UL pproved F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT 8 Non UL 37 3 E Product coding example: 37D3ZE-H98: 68 series ½" NPT, auto, brass body, PTFE seals, 0 V / 60 Hz, ½" NPT electrical connection, Non UL. Keeping the World Flowing 3

14 UCD Series / Normally Closed Mode of Operation Maximum Viscosity 3 /8 - Body Material (Std) /4 - Body Material (Std) Flange Tube Plunger and top stop Springs Seal Material Connection Type Shading Ring Coil Voltage DC (=) Coil Voltage C 60 Hz (~) Specifications Normally Closed, energise to open Out () In () SSU Brass (Std) or option Bronze (Std) Nitrile (BunaN) (Std) other options available NPT Copper (std), Silver (stainless steel option) Electrical Characteristics V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Electrical Connection options 00% ED / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Features and Benefits Two way shut-off valves for the control of gases and liquids compatible with max viscosity and materials Zero bar minimum operating pressure Satisfy all relevant EC directives Robust Valve Design Diaphragm Operation Fully Ported Orifices for high flow Choice of valve body material seals Sizes 3 /8-3 /4 approved to BS EN for household use when used with EPDM seals Response time -60 ms Response time 60-0 ms EN64 for fuel oils Tested in accordance with BS-EN 66- Suitable for vacuum applications when fitted with Viton seals (0-3 TORR) - 0 rated models only Port size Cv Kv C OPD (psi) DC 3 / P. Max psi Orifice (mm) Weight (lbs) 6.0 ½ Coil Insulation Power Rating Class H 4. Watts ¾ ¼ ½ Options vailable EExd T6 EExd T4 Seal Material and Media Temp. Range Solenoid Enclosure Protection Class See separate datasheet mbient Temperature Range Min Max Nitrile (4 ºF to +76 ºF) 4 ºF ºF ¼ ½ Pressure assisted to achieve a greater OPD. e.g. code 9G3Z-F9. Main valve body options 36 (up to and including ") Manual Override Oxygen Cleaning (consult factory for product code) Tagging (consult factory for product code) EPDM (-8 ºF to +48 ºF) 4 ºF ºF Viton (-4 ºF to +30 ºF) 4 ºF ºF. Water Flow (GPM) See corrosion reference guide and sealing solutions for material compatability. How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model. Pressure Drop (Bar) 6.0 mm orifice 6.0 mm orifice 6.0 mm orifice 0.0 mm orifice 40.0 mm orifice 40.0 mm orifice Water Flow (L/Min) 0 3 Pressure Drop (PSI) 4

15 UCD Series / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options D B C Dimensions Port size B C D 3 /8 - ¾ ¾ 3 7 /6 3" 4 3 /8 3 3 /8 3 7 /6 3" 3 /8 ¼ - 3 /8 4 /8 4¾ 7/8" Dimensions given in inches Stainless steel option dimensions vary from table - consult factory. Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Valve Body Conn. Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical Connection pproval C VOLTGE DC 3 VOLTGE Pressure assisted option ¼"to " C 3 /8 D ½ E ¾ F G ¼ H ½ J 3 NPT UTO MNUL OVERIDE Z Default Brass (standard on valves up to and including ) Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) B C Nitrile EPDM VITON Standard S4 type enclosure -metal can (IP0) UL pproved F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT UL/ CS 3 Z ¼ to " '0' pressure rated options are not available in DC voltages Product coding example: 7C3ZB-H9: UCD Series 3 /8 NPT, uto, Brass body, EPDM (WRS approved) seals, 0 V / 60 Hz / NPT electrical connection UL/CS approval. Keeping the World Flowing

16 UCD Series Exd / Normally Closed TEX Mode of Operation Maximum Viscosity 3 /8 - Body Material (Std) /4 - Body Material (Std) Flange Tube Plunger and top stop Springs Seal Material Connection Type Specifications Normally Closed, energise to open Out () SSU In () Brass (Std) or option Bronze (Std) Nitrile (BunaN) (Std) other options available NPT Features and Benefits Robust Valve Design Diaphragm Operation Fully Ported orifices for high Kv Choice of valve body material seals TEX pproved Response time up to -60 ms Response time up to 60-0 ms Tested in accordance with BS-EN 66-z Shading Ring Coil Voltage DC (=) Coil Voltage C 60 Hz (~) Copper (std), Silver (stainless steel option) Electrical Characteristics V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Protection Class (Exd) Electrical Connection (Exd) Coil Insulation 00% ED II G Ex d IIC T4 Tamb (-8 F to + 8 F) II G Ex d IIC T6 Tamb (-8 F to + 04 F) Class Zone Groups II, IIB, IIC gases ½ NPT Port (Std) Class H Port size Cv Kv C OPD (psi) DC 3 / P. Max psi Orifice (mm) Weight (lbs) excluding solenoid 6.0 ½ ¾ ¼ ½ ¼ ½ Power Rating 4. Watts Options vailable Pressure assisted to achieve a greater OPD. e.g. code 9G3Z3-F9G. Protection Class Exd T4 Exd T6 Solenoid Enclosure Electrical Entry ½ NPT conduit (std) M0 X. conduit (option) See corrosion reference guide and sealing solutions for material compatability. Enclosure Material luminium (Std) optional Seal Material and Media Temp. Range mbient Temperature Range Min Max (T6) Max (T4) Nitrile (4 ºF to +76 ºF) 4 ºF 04 ºF 8 ºF EPDM (-8 ºF to +48 ºF) -8 ºF 04 ºF 8 ºF Viton (-4 ºF to +30 ºF) -4 ºF 04 ºF 8 ºF Main valve body options 36 (up to and including ") Manual Override Oxygen Cleaning (consult factory for product code) Tagging (consult factory for product code). Water Flow (GPM) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model. Pressure Drop (Bar) 6.0 mm orifice 6.0 mm orifice 6.0 mm orifice 0.0 mm orifice 40.0 mm orifice 40.0 mm orifice Water Flow (L/Min) 3 Pressure Drop (PSI) 6

17 UCD Series Exd / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options /" NPT (std) luminium enclosure as standard 3 /64" 4 /64" 7 /64" Dimensions Port size B C D Exd 3 /8 - ¾ 47 / /3" 6 /64" 33 /64" 47 /64" 4 7 /3" 6 /64" 33 /64" ¼ - /64" /3" 4 3 /3" 7 3 /3" Dimensions given in inches Solenoid enclosures Exd S4 type enclosure Power consumption: External material: Electrical entry: Holding 9 V, V to 30 V 0 / 60 Hz. 4. W, V to VDC Powder coated aluminium or 36 st.st. enclosure with st.st. nameplate M0 x. or / NPT conduit entry Protection Class: II G Exd IIC T6 for ambient temp -8 F to +04 F Optional: II G Exd IIC T4 for ambient temp -8 F to +8 F Weight:.8 lbs luminium or 3.3 lbs - CS approval lcon flame proof enclosures are suitable for the following areas / gases: Zones & Class Division Class Division Groups: II, IIB, IIC gases Main Valve ssembly Coil options Model Valve Body Conn. Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection T Rating pproval C VOLTGE DC 3 VOLTGE Pressure assisted option ¼ to " C 3 /8 D ½ E ¾ F G ¼ H ½ J 3 NPT UTO MNUL OVERIDE Z Default Brass (standard on valves up to and including Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) B C Nitrile EPDM VITON 3 Exd 6 Exd luminium Exd Stainless Steel F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz M0x. 9 / NPT 9 tex T6 949 tex T4 G (CS) 3 Z 3 - G 3 ¼ to " '0' pressure rated options are not available in DC voltages. Product coding example: 7C3ZB3-H99G: UCD Series Exd 3 /8, NPT uto, Brass body, EPDM seals, 0 V / 60Hz, luminium Exd enclosure, / NPT electrical connection, T6, CS approval. Keeping the World Flowing 7

18 CDN Series / Normally Open Mode of Operation Maximum Viscosity 3 /8 - Body Material (Std) /4 - Body Material (Std) Flange Tube Plunger and top stop Springs Seal Material Connection Type Specifications Normally Closed, energise to close Out () In () SSU Brass (Std) or option Bronze (Std) Nitrile (BunaN) (Std) other options available NPT Features and Benefits Robust Valve Design Diaphragm Operation Fully Ported Orifices for high flow Choice of valve body material seals Sizes 3 /8-3 /4 dvantica approved to BS EN for household use when used with EPDM seals Response time -60 ms Response time 60-0 ms Tested in accordance with BS-EN 66- Shading Ring Coil Voltage DC (=) Coil Voltage C 60 Hz (~) Copper (std), Silver (stainless steel option) Electrical Characteristics V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Electrical Connection options Coil Insulation 00% ED / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Port size Cv Kv C OPD (psi) DC 3 / P. Max psi Orifice (mm) Weight (lbs) 6.0 ½ ¾ ¼ ½ Power Rating 4. Watts Options vailable EExd T6 EExd T4 Solenoid Enclosure Protection Class See separate datasheet Seal Material and Media Temp. Range mbient Temperature Range Min Max Nitrile (4 ºF to +76 ºF) 4 ºF ºF EPDM (-8 ºF to +48 ºF) 4 ºF ºF Viton (-4 ºF to +30 ºF) 4 ºF ºF Main valve body options 36 (up to and including ") Oxygen Cleaning (consult factory for product code) Tagging (consult factory for product code) See corrosion reference guide and sealing solutions for material compatability.. Water Flow (GPM) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model. Pressure Drop (Bar) 6.0 mm orifice 6.0 mm orifice 6.0 mm orifice 0.0 mm orifice 40.0 mm orifice 40.0 mm orifice Water Flow (L/Min) 3 Pressure Drop (PSI) 8

19 CDN Series / Normally Open Coil Rotation 360º Preferred Valve Mounting Options D B Dimensions Port size B C D 3 /8 - ¾ ¾ 3 7 /6" 3" 4 3 /8" C 3 3 /8 3 7 /6" 3" 3 /8" ¼ - 3 /8 4 /8" 4¾ 7 /8" Dimensions given in inches Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Valve Body Conn. Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval 7 6 CDN (¼ and above) CDN ( 3 /8"-") C 3 /8 D ½ E ¾ F G ¼ H ½ J 3 NPT UTO Z Default Brass (standard on valves up to and including ) Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) B C Nitrile EPDM VITON Standard C N/O standard metal can F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT 8 Non- UL 3 Z - C 9 8 Product coding example: 6C3Z-CH98: CDN Series 3 /8 NPT, uto, Brass body, nitrile seals, 0 V / 60Hz, / NPT electrical connection, non-ul. Keeping the World Flowing 9

20 CDN Series Exd / Normally Open Mode of Operation Maximum Viscosity 3 /8 - Body Material (Std) /4 - Body Material (Std) Flange Tube Plunger and top stop Springs Seal Material Connection Type Shading Ring Specifications Normally open, energise to close Out () In () SSU Brass (Std) or option Bronze (Std) Nitrile (BunaN) (Std) other options available NPT Copper (std), Silver (stainless steel option) Features and Benefits Robust Valve Design Diaphragm Operation Fully Ported Orifices for high Kv Choice of valve body material seals Sizes 3 /8 - dvantica approved to BS EN for household use. Response time up to -60 ms Response time up to 60-0 ms Tested in accordance with BS-EN 66- Electrical Characteristics Coil Voltage DC (=) V, 4 V Coil Voltage C 60 Hz (~) 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Protection Class (Exd) Electrical Connection (Exd) 00% ED II G Ex d IIC T4 Tamb (-8 F to + 8 F) II G Ex d IIC T6 Tamb (-8 F to + 04 F) Class Zone Groups II, IIB, IIC gases ½ NPT Port (Std) Port size Cv Kv C OPD (psi) DC 3 / P. Max psi Orifice (mm) Weight (lbs) excluding solenoid 6.0 ½ ¾ ¼ Coil Insulation Power Rating Class H 4. Watts ½ Options vailable Protection Class Exd T4 Exd T6 Solenoid Enclosure Electrical Entry ½ NPT conduit (std) M0 X. conduit (option) Enclosure Material luminium (Std) optional Seal Material and Media Temp. Range mbient Temperature Range Min Max (T6) Max (T4) Nitrile (4 ºF to +76 ºF) 4 ºF 04 ºF 8 ºF EPDM (-8 ºF to +48 ºF) -8 ºF 04 ºF 8 ºF Viton (-4 ºF to +30 ºF) -4 ºF 04 ºF 8 ºF Main valve body options 36 (up to and including ") Oxygen Cleaning (consult factory for product code) Tagging (consult factory for product code) See corrosion reference guide and sealing solutions for material compatability.. Water Flow (GPM) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model. Pressure Drop (Bar) 6.0 mm orifice 6.0 mm orifice 6.0 mm orifice 0.0 mm orifice 40.0 mm orifice 40.0 mm orifice Water Flow (L/Min) 3 Pressure Drop (PSI) 0

21 CDN Series Exd / Normally Open Coil Rotation 360º Preferred Valve Mounting Options /" NPT (std) 3 /64" luminium enclosure as standard 4 /64" 7 /64" Dimensions Port size B C D Exd 3 /8 - ¾ 47 /64" 4 7 /3" 6 /64" 33 /64" 47 /64" 4 7 /3" 6 /64" 33 /64" ¼ - /64" 4 /6" 4 3 /3" 7 3 /3" Dimensions given in inches Solenoid enclosures Exd S4 type enclosure Power consumption: External material: Electrical entry: Holding 9 V, V to 30 V 0 / 60 Hz. 4. W, V to VDC Powder coated aluminium or 36 st.st. enclosure with st.st. nameplate M0 x. or / NPT conduit entry Protection Class: II G Exd IIC T6 for ambient temp -8 F to +04 F Optional: II G Exd IIC T4 for ambient temp -8 F to +8 F Weight:.8 lbs luminium or 3.3 lbs - CS approval lcon flame proof enclosures are suitable for the following areas / gases: Zones & Class Division Class Division Groups: II, IIB, IIC gases Main Valve ssembly Coil options Model Valve Body Conn. Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval 7 6 CDN (¼ and above) CDN ( 3 /8"-") C 3 /8 D ½ E ¾ F G ¼ H ½ J 3 NPT UTO Z Default Brass (standard on valves up to and including ) Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) B C Nitrile EPDM VITON 3 Exd D E N/O Exd luminium N/O Exd Stainless Steel F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 M0 x. / NPT 8 T6 849 T4 3 Z 3 - Product coding example: 6C3Z3-DH98: CDNEXD 3 /8 NPT, auto, brass body, nitrile seals, aluminium housing, 0 V / 60 Hz, ½ NPT electrical connection ExdT6. Keeping the World Flowing

22 UCP Series / Normally Closed Mode of Operation Maximum Viscosity 3 /8 - Body Material (Std) /4 - Body Material (Std) Flange Tube Plunger and top stop Springs Seal Material Connection Type Shading Ring Specifications Normally Closed, energise to open Out () In () SSU Brass (Std) or option Bronze (Std) Nitrile (BunaN) (Std) other options available NPT Copper (std), Silver (stainless steel option) Features and Benefits Heavy duty valve design Piston operation Choice of valve body material and seals Wide temperature range capabilities Response time up to ms Response time up to ms Tested in accordance with BS-EN 66- Electrical Characteristics Coil Voltage DC (=) Coil Voltage C 60 Hz (~) V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Electrical Connection options Coil Insulation 00% ED / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Port size Cv Kv C OPD (psi) DC ½ P. Max psi Orifice (mm) Weight (lbs) ¾ ¼ Power Rating 4. Watts ½ Options vailable EExd T6 EExd T4 Solenoid Enclosure Protection Class See separate datasheet Seal Material and Media Temp. Range mbient Temperature Range Min Max Nitrile (4 ºF to +76 ºF) 4 ºF ºF EPDM (-8 ºF to +48 ºF) 4 ºF ºF Viton (-4 ºF to +30 ºF) 4 ºF ºF Main valve body options 36 (up to and including ") Oxygen Cleaning (consult factory for product code) Tagging (consult factory for product code) See corrosion reference guide and sealing solutions for material compatability.. Water Flow (GPM) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model. Pressure Drop (Bar) 6.0 mm orifice 6.0 mm orifice.0 mm orifice 30.0 mm orifice 3.0 mm orifice Water Flow (L/Min) 0 3 Pressure Drop (PSI)

23 UCP Series / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options D B Dimensions C Port size B C D 3 /4" /" 4 /8" /4" 4 3 /6" " 4 /4" 4 /6" 3" 3 /4" /4" - /" 4 /8" /4" 3 /4" 8 /4" " 3 /4" 3 /4" 4" 8 /4" Dimensions given in inches Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Valve Body Conn. Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval UCP D ½ E ¾ F G ¼ H ½ J 3 NPT UTO Z Default Brass (standard on valves up to and including ) Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) B C Nitrile EPDM VITON Standard S4 type enclosure -metal can (IP0) UL pproved F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT UL/CS 3 Z - 9 Product coding example: D3Z-H9: UCP Series ½ NPT, uto, Brass body, nitrile seals, 0 V / 60 Hz, / NPT electrical connection UL/CS approval. Keeping the World Flowing 3

24 UCP Series Exd / Normally Closed Mode of Operation Maximum Viscosity 3 /8 - Body Material (Std) /4 - Body Material (Std) Flange Tube Plunger and top stop Springs Seal Material Connection Type Specifications Normally closed, energise to open Out () In () SSU Brass (Std) or option Bronze (Std) Nitrile (BunaN) (Std) other options available NPT Features and Benefits Heavy duty valve design Piston Operation Wide temperature range capabilities Choice of valve body material seals TEX approved. Response time up to ms Response time up to ms Tested in accordance with BS-EN 66- Shading Ring Copper (std), Silver (stainless steel option) Electrical Characteristics Coil Voltage DC (=) Coil Voltage C 60 Hz (~) V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Protection Class (Exd) Electrical Connection (Exd) Coil Insulation 00% ED II G Ex d IIC T4 Tamb (-8 F to + 8 F) II G Ex d IIC T6 Tamb (-8 F to + 04 F) Class Zone Groups II, IIB, IIC gases ½ NPT Port (Std) Class H Port size Cv Kv C OPD (psi) DC ½ P. Max psi Orifice (mm) Weight (lbs) excluding Solenoid Protection Class Exd T6 ¾ Exd T Exd T6 7 ¼ Exd T6 ½ Exd T6 Power Rating 4. Watts Exd T6 Options vailable Protection Class Exd T4 Exd T6 Solenoid Enclosure Electrical Entry ½ NPT conduit (std) M0 X. conduit (option) Enclosure Material luminium (Std) optional Seal Material and Media Temp. Range mbient Temperature Range Min Max (T6) Max (T4) Nitrile (4 ºF to +76 ºF) 4 ºF 04 ºF 8 ºF EPDM (-8 ºF to +48 ºF) -8 ºF 04 ºF 8 ºF Viton (-4 ºF to +30 ºF) -4 ºF 04 ºF 8 ºF Main valve body options 36 (up to and including ") Oxygen Cleaning (consult factory for product code) Tagging (consult factory for product code) See corrosion reference guide and sealing solutions for material compatability.. Water Flow (GPM) How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model. Pressure Drop (Bar) 6.0 mm orifice 6.0 mm orifice.0 mm orifice 30.0 mm orifice 3.0 mm orifice Water Flow (L/Min) 0 3 Pressure Drop (PSI) 4

25 UCP Series Exd / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options 3 /64" 4 /64" 9 /3" Exd Dimensions Port size B C D 3 /4 3 /3" /64" 6 /64" 6½" 3 /3" 7 3 /64" 6 /64" 7 /64" ¼ - ½ 4 39 /64" 6 3 /3" 3 7 /64" 9 9 /64" 3 /4" 7 7 /6" 4 /6" 9 9 /64" Dimensions given in inches Solenoid enclosures Exd S4 type enclosure Power consumption: External material: Electrical entry: Holding 9 V, V to 30 V 0 / 60 Hz. 4. W, V to VDC Powder coated aluminium or 36 st.st. enclosure with st.st. nameplate M0 x. or / NPT conduit entry Protection Class: II G Exd IIC T6 for ambient temp -8 F to +04 F Optional: II G Exd IIC T4 for ambient temp -8 F to +8 F Weight:.8 lbs luminium or 3.3 lbs - CS approval lcon flame proof enclosures are suitable for the following areas / gases: Zones & Class Division Class Division Groups: II, IIB, IIC gases Main Valve ssembly Coil options Model Valve Body Conn. Size Connection Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection T Rating pproval UCP D ½ E ¾ F G ¼ H ½ J 3 NPT UTO Z Default Brass (standard on valves up to and including ) Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) B C Nitrile EPDM VITON 3 Exd 6 Exd luminium Exd Stainless Steel F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz M0x. 9 / NPT 9 tex T6 949 tex T4 G CS 3 Z 3 - G Product coding example: D3Z3-H9G: UCP EXD Series ½ NPT, uto, Brass body, nitrile seals, 0 V / 60 Hz, / NPT electrical connection, T6, CS approval. Keeping the World Flowing

26 UCPX Series: Steam / Normally Closed Mode of Operation Maximum Viscosity 3 /8 - Body Material (Std) /4 - Body Material (Std) Flange Tube Plunger and top stop Springs Seal Material Connection Type Shading Ring Specifications Normally closed, energise to open Out () In () SSU Brass (Std) or option Bronze (Std) PTFE NPT Copper (std), Silver (stainless steel option) Features and Benefits Heavy Duty Valve Design Piston Operation Wide temperature range capabilities Choice of valve body material seals Tested in accordance with BS-EN 66- Electrical Characteristics Coil Voltage DC (=) Coil Voltage C 60 Hz (~) V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Electrical Connection options Coil Insulation Power Rating 00% ED / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H 4. Watts Port size Cv Kv C OPD (psi) DC ½ P. Max psi Orifice (mm) Weight (lbs) ¾ ¼ ½ Options vailable Protection Class EExd T6 EExd T4 Solenoid Enclosure Consult Rotork Midland for product codes Seal Material and Media Temp. Range mbient Temperature Range Min See corrosion reference guide and sealing solutions for material compatability. Max PTFE (-38 ºF to +36 ºF) 4 ºF ºF Main valve body options 36 (up to and including ") Oxygen Cleaning (consult factory for product code) Tagging (consult factory for product code). 0 0 Steam flow lb/hr How to use the flow chart. Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model. Pressure drop (Bar) 0. Flow shown is with steam at 8 psi 6.0 mm orifice.0 mm orifice 30.0 mm orifice 3.0 mm orifice Steam flow kg/hr Pressure drop (PSI) 6

27 UCPX Series: Steam / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options D B Dimensions C Port size B C D 3 /4" /" 4 /8" /4" 4 3 /6" " 4 /4" 4 /6" 3" 3 /4" /4" - /" 4 /8" /4" 3 /4" 8 /4" " 3 /4" 3 /4" 4" 8 /4" Dimensions given in inches Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated ½ NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Valve Body Conn. Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval UCPX D ½ E ¾ F G ¼ H ½ J 3 NPT UTO Z Default Brass (standard on valves up to and including ) Bronze (standard on valves above ) 36 Stainless Steel (option available up to and inc ) E PTFE Standard S4 type enclosure -metal can (IP0) UL pproved F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT UL/ CS 3 Z E - 9 Product coding example: D3ZE-H9: UCPX Series ½ NPT, uto, Brass body, PTFE seals, 0 V / 60 Hz, / NPT electrical connection UL/CS approval. Keeping the World Flowing 7

28 UGB Series / Normally Closed Mode of Operation Body Material Flange Tube Plunger and top stop Springs Seal Material Connection Type Shading Ring Coil Voltage C 60 Hz (~) Specifications Normally closed, energise to open Out () luminium Nitrile (BunaN) (Std) other options available NPT Copper Electrical Characteristics 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle In () 00% ED Features and Benefits pproved for mains gas safety shut off Suitable for automatic burners Suitable for fire protection systems Ideal for low pressure Natural gas pproved to EN6 Compliant with Gas ppliance directive Fully ported Orifices for high flow Zero pressure rated Optional pressure test points Suitable for st, nd and 3rd family gases Suitable for LPG Response time up to ½ - ms Response time up to 0-40 ms Consult factory for pressure rating Panic buttons & electro thermal links available for controlling valve Electrical Connection Options / NPT metal conduit hub with 8 leads (NEM equivalent protection class) Coil Insulation Class H Power Rating ¼ - ½ - 4 Watts ¾ - - Watts Port size Cv Kv OPD (psi) C P. Max psi Orifice (mm) Weight (lbs) / / / / Options vailable Seal Material and Media Temp. Range mbient Temperature Range Min Max Nitrile (4 ºF to +76 ºF) 3 ºF 40 ºF Kv = flow rate measured with differential pressure at psi Main valve body options Tagging (consult factory for product code) See corrosion reference guide and sealing solutions for material compatability. Natural gas flow Ft³/hr How to use the flow chart Pressure drop (mbar).7 mm orifice.7 mm orifice.7 mm orifice 9.0 mm orifice 9.0 mm orifice Pressure drop ( WG). Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model Natural gas flow M³/hr

29 UGB Series / Normally Closed Coil Rotation 360º Preferred Valve Mounting Options C B D Dimensions Port size B C D ¼ ¼ 3" 3" 3 /8" 3 /8 ¼ 3" 3" 3 /8" ½ ¼ 3" 3" 3 /8" 3 /4 3 3 /8" 3 9 /6" 9 /6" 4¼ 4 3 /8" 3 9 /6" 9 /6" 4 7 /6" Dimensions given in inches Solenoid enclosures S4 Type enclosure protection class IP0 External material: Electrical entry: Winding Insulation: Pressed steel powder coated ½ NPT metal conduit hub with 8 leads (NEM equivalent protection class) Class H Main Valve ssembly Coil options Model Valve Body Conn. Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval 34 UGB B ¼ C 3 /8 D ½ E 3 /4 F 3 NPT UTO Z Default 3 luminium Nitrile Standard S4 type enclosure -metal can (IP0) UL pproved H H H 4 V / 60 Hz 0 V / 60 Hz ( /4" to /" only) 0 V / 60 Hz ( 3 /4" to " only) 9 / NPT UL 34 3 Z 3-9 Product coding example: 34B3Z3-H9: UGB Series /4 NPT, uto, brass body, Nitrile seals, 0 V / 60 Hz, ½ NPT electrical connection, UL. Keeping the World Flowing 9

30 Namur Series 3/, / Universal Mode of Operation Media Body Material Flange Tube Plunger and top stop Springs Seal Material Specifications Normally Closed, energise to open 3/ Orientation / Orientation ir nodised luminium Brass Nitrile (BunaN) (Std) Features and Benefits Zero pressure rated Ideal for in-line system service and repair Manual Overide Low power LED Light Dual Coil option Exd and Exia compatible Max cycle frequency /sec Electrical Characteristics Coil Voltage DC (=) Coil Voltage C 60 Hz (~) 4 V 0 V Voltage Tolerance +0% or -0% Duty Cycle Electrical Connection Options Coil Insulation Power Rating 00% ED 9mm din connector (NEM 4 equivalent protection class) Class F Watts Port size Cv Kv C OPD (psi) DC P. Max psi Weight (lbs) ¼ Options vailable Solenoid Enclosure Protection Class Seal Material and Media Temp. Range mbient Temperature Range Min Max EExd T6 EExd T4 See separate datasheet Nitrile (4 ºF to +76 ºF) 4 ºF ºF See corrosion reference guide and sealing solutions for material compatability. Universal Series - / ir flow (Ft³/H) How to use the flow chart Pressure Drop (Bar) CV =.4, KV= Pressure Drop (PSI). Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model Flow (M³/H)

31 Namur Series 3/, / Universal /4" Preferred Valve Mounting Options Discs shown in 3/ 37 /64" Manual override - off ¼ NPT exhaust connections - off /8" x /64" O rings to seal on Namur interface /6" Discs shown in / ¼ NPT for inlet pilot supply pressure 7 /64" Dimensions given in inches /6" Solenoid enclosures S7 enclosure protection class IP6 (NEM 4 equivalent) External material: Nylon Electrical connection: DIN Plug to ISO 4400 Winding: Insulation Class F Conforms to IP6 when correct plug seal gasket is fitted. Main Valve ssembly Coil options Model Size Connection Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval 6 Namur B ¼ 3 NPT MNUL OVERRIDE Z Default 3 luminium Nitrile Standard Weather Proof IP6 (NEM 4) QY R 0 V / 60 Hz 4 VDC Din plug 9mm 8 Non UL 6 B 3 Z 3-8 Not needed for DC option Product coding example: 6B3Z3-QY8: Namur, IP6 (NEM 4 equivalent), /4 NPT, manual override, luminium body, Nitrile seals, 0 V / 60 Hz, electrical connection 9 mm DIN. Keeping the World Flowing 3

32 Namur Series Exd & Exia 3/, / Universal Mode of Operation Media Body Material Flange Tube Specifications 3/ or / 3/ Orientation / Orientation ir nodised luminium Brass Features and Benefits Zero pressure rated Ideal for in-line system service and repair Choice of valve body material seals Manual Overide Low power LED Light Dual Coil option Exd, Exia compatible CS approval (for Exd only) Max cycle frequency /sec Plunger and top stop Springs Seal Material Coil Voltage DC (=) Coil Voltage C 60 Hz (~) Nitrile (BunaN) (Std) Electrical Characteristics V, 4 V 4 V, 0 V Voltage Tolerance +0% or -0% Duty Cycle Protection Class (Exd) Protection Class (Exia) 00% ED II G Ex d IIC T4 Tamb (-8 F to + 8 F) II G Ex d IIC T6 Tamb (-8 F to + 04 F) Class Zone Groups II, IIB, IIC gases Exia IIC T6 (-40 F to + F) (NEM 4 equivalent) Port size Cv Kv C OPD (PSI) DC P. Max Bar Protection Class Weight (lbs) excluding Solenoid ¼ Exd 0.4 Options vailable Solenoid Enclosure Protection Class Electrical Entry Enclosure Material EExd T6 EExd T4 Exia ½ NPT conduit (std) M0 X. conduit (option) 9 mm DIN connector luminium Thermoset resin Weather Proof (NEM 4 equivalent) Electrical Connection (Exd) Electrical Connection (Exia) Coil Insulation Power Rating (Exd) Power Rating (Exia) ½ NPT Port (Std) PG9 via Din Plug connector Class F Watts.6 Watts Seal Material and Media Temp. Range mbient Temperature Range Min Max (T6) Max (T4) Max (Exia) Nitrile (4 ºF to +76 ºF) 4 ºF 04 ºF 8 ºF ºF See corrosion reference guide and sealing solutions for material compatability. Universal Series - / ir flow (Ft³/H) How to use the flow chart Pressure Drop (Bar) CV=.4, KV= Pressure Drop (PSI). Select the required flow.. Note the corresponding pressure drop. 3. Based on where the two points intersect select the most appropriate model Flow (M³/H)

33 Namur Series Exd & Exia 3/, / Universal 3 /64" Solenoid enclosures 7 /64" 3 /64" ½" NPT (std) Cable Entry Exhaust ports ¼ BSP or NPT Inlet port ¼ BSP or NPT Exd S4 type enclosure Power consumption: External material: Electrical entry: Holding 9 V, V to 30 V 0 / 60 Hz. 4. W, V to VDC Powder coated aluminium or 36 st.st. enclosure with st.st. nameplate / NPT conduit entry (standard) Protection Class: II G Exd IIC T6 for ambient temp -8 F to +04 F Optional: II G Exd IIC T4 for ambient temp -8 F to +8 F Weight:.8 lbs luminium or 3.3 lbs - Manual override Exd ½" For Exm and Exia dimensions consult customer services 3 /6" /3" 7 /64" 3 /64" M 7 /64" 43 /64" 3 /64" /6" CS approval lcon flame proof enclosures are suitable for the following areas / gases: Zones & Class Division Class Division Groups: II, IIB, IIC gases Disc arrangement 3/ mode /6" /64" 3 /64" 9 /3" lcon solenoid operator Exd IIC T6 - IP67 NEM 6 Equivalent TEX approved 37 /64" Intrinsically safe enclosure (TEX approved) External material: Thermoset resin Electrical connection: PG9 via DIN plug connector Din Max power consumption: Winding: Protection class: Exia.6 Watts DC. Insulation Class F Exia IIC T6, TEX approved for ambient temperatures -40 ºF to + ºF Disc arrangement / mode O rings /8" x /64" to seal on Namur interface For Exia option use product code 6B3Z3E-QJ. For all other coding options see below: Main Valve ssembly Coil options Model Size Conn. Type Operation Orifice (mm) Body Material Seals Style Enclosure Voltage / Frequency Electrical connection pproval 6 Namur B ¼ 3 NPT Manual Override Z Default 3 luminium Nitrile 3 Exd 9 Exd luminium F F4 H H 4 VDC VDC 4 V / 60 Hz 0 V / 60 Hz 9 / NPT 9 K tex T6 tex T4 6 B 3 Z Product coding example: 6B3Z33-9H99: Namur Exd /4 NPT, manual override, luminium body, Nitrile seals 0 / 60 Hz / NPT electrical connection T6. Keeping the World Flowing 33

34 CONVERSIONS Capacity & flow rate Multiply number of by to obtain Cubic metres/ hour Litres /sec Litres /min Cubic metres/sec (cumec) UK gpm US gpm Cubic ft/sec (cusec) UK ton/h m 3 /h l/s l/m x m 3 /s ,000 3,00,800 3, UK gpm US gpm ft 3 /s UK ton/h tonne/h Water tonne/h Volumetric rate of flow Multiply number of by to obtain Litres /sec Litres /min Cubic metres/ hour Cubic ft/ hour Cubic ft/ min Imperial Gallons/min U.S. Gallons/min U.S. Barrels/day Litres per sec Litres per min Cubic metres per hour Cubic Feet per hour Cubic Feet per min Imperial Gallons per min U.S. Gallons per min U.S. Barrels per day MGD = 89.4 m 3 /h scfm =.699 Nm 3 /h Temperature To convert from To Fahrenheit To Celcius To Kelvin Fahrenheit (F) F (F-3) * /9 (F-3) * / Celcius (C) (C*9/) + 3 C C Kelvin (K) (K - 73.) * 9/ + 3 K K Pressure Multiply number of by to obtain bar psi (lbf/in ) Cm water (39. F, 4 C) Inch of water (39. F, 4 C) Foot of water (39. F, 4 C) Kilopascal (kpa) Bar Psi (lbf/in) Cm water (39. F, 4 C) Inch of water (39. F, 4 C) Foot of water (39. F, 4 C) Kilopascal (kpa)

35 CORROSION REFERENCE GUIDE This chart is for general recommendation only. When ordering valves for corrosive duty application details are to be given, particularly media, % concentration, temperature and ambient temperature. For additional support please contact us. Valve Body Seals Notes Material lum Brass Brz CI Stainless Nitrile EPDM Viton PTFE cetic cid 0% NR NR NR NR NR NR cetone NR NR cetylene NR NR NR ir mmonia Gas nhydrous 0% NR NR NR NR NR rgon Gas NR NR Beer NR NR NR NR NR Benzene NR NR NR Bromine (Liquid) NR NR NR NR NR NR NR NR Butane NR Carbon Dioxide (Gas).. Carbon Dioxide (Liquid) NR NR NR NR NR NR NR Carbon Tetrachloride (Dry) NR NR NR NR Carbonated Water NR NR NR NR NR Caustic Soda 30% NR NR NR NR NR NR Chrome cid 0% - 0C NR NR NR NR NR NR Chlorine Gas (Dry) NR NR NR NR NR NR NR Chlorine Liquid NR NR NR NR NR NR NR Chlorine in Water NR NR NR Coke Oven Gas NR NR. NR NR Coolant NR NR NR Creosote NR NR NR NR NR Crude Oil NR NR NR NR De-ionized Water NR NR NR NR De-mineralised Water NR NR NR NR Detergents NR NR Diesel Oil NR Distilled Water NR NR Ethyl lchohol NR NR Ethylene Glycol NR. Ethylene Oxide NR NR NR NR NR NR NR NR Food Products NR NR NR NR NR NR Freon NR NR NR NR Freon NR NR NR NR NR NR NR Freon Solvents NR NR NR NR Fuel Oil NR NR Gasoline NR NR NR NR Helium NR Hydraulic Fluids NR NR NR NR Hydrochloric cid NR NR NR NR NR NR NR NR Hydrogen Gas 3 Hydrogen Sulphide (dry) NR NR NR NR NR Jet Fuel NR NR NR NR Kerosene NR Notes:. Non-standard materials of construction are required.. Chlorine must not exceed parts per million. 3. lcon is required to provide industry standard degreasing, cleaning and individual packaging with appropriate label. = Recommended NR = Not Recommended Keeping the World Flowing 3

36 CORROSION REFERENCE GUIDE This chart is for general recommendation only. When ordering valves for corrosive duty application details are to be given, particularly media, % concentration, temperature and ambient temperature. For additional support please contact us. Valve Body Seals Notes Material lum Brass Brz CI Stainless Nitrile EPDM Viton PTFE LPG NR NR Lubricating Oil NR Methane Gas NR Methyl lcohol NR Mineral Oil NR Natural Gas Natural Gas Liquid NR NR NR NR NR 3 Nitric cid 0% 0C NR NR NR NR NR NR Nitrogen gas Nitrogen Liquid NR NR NR NR NR 3 Nitrous Oxide NR NR NR NR NR NR Oxygen Gas NR NR NR NR 3 Oxygen Liquid NR NR NR NR 3 Paraffin NR Perchlcrenthylene 0C NR NR NR NR Phosperic cid 30% NR NR NR NR NR Photographic solution NR NR NR NR NR NR NR NR Potable water NR NR Potassium Sulphate NR NR NR Propane NR NR Salt Water NR NR NR Sea Water NR NR NR Soapy Water NR NR NR Sodium Hydroxide 70% NR NR NR NR NR Sodium Hypochorite % NR NR NR NR NR Steam 0-0 psi NR NR NR NR Steam 0 - psi NR NR NR NR NR Steam Condensate NR NR NR NR Sulphur Dioxide NR NR NR NR NR NR Sulphuric cid 40% NR NR NR NR NR Sulphurous cid % - 0C NR NR NR NR NR NR NR Toluene NR NR NR NR Town Gas NR Trichlorethylene (Dry) NR NR NR NR NR NR Turpentine NR NR Vegetable Oil NR NR NR NR NR Vinegar NR NR NR NR NR NR Water (mains) NR Water 80-0 C NR NR NR Water 0-0 C NR NR NR NR Water 0-80 C NR NR NR NR NR Water boiler feed NR NR NR NR NR Water/Glycol Solutions NR NR NR White Spirit NR NR Notes:. Non-standard materials of construction are required.. Chlorine must not exceed parts per million. 3. lcon is required to provide industry standard degreasing, cleaning and individual packaging with appropriate label. = Recommended NR = Not Recommended 36

37 VISCOSITY REFERENCE GUIDE Redwood (Seconds) Redwood (Seconds) Saybolt Universal SSU (Seconds) Saybolt Fural (Seconds) Engler (Degrees) Kinematic (Centistrokes) Keeping the World Flowing 37

38 COPPER WINDING TEMPERTURE CLSSIFICTION Insulation systems are arranged in order of their insulation level and classified by a letter symbol or by a numerical value. The numerical value relates to the temperature classification of the insulation system. The temperature classification indicates the maximum (hotspot) temperature at which the insulation system can be operated for normal expected service life. In general, all materials used in a given insulation system should be rated for temperatures equal to, or exceeding, the temperature classification of the system. Features and Benefits Zero pressure rated Ideal for in-line system service and repair Choice of valve body material seals Manual Overide Low power LED Light Dual Coil option Exd, Exia and Exm compatible Max cycle frequency /sec Insulation Systems* Temperature Classification Class Class 0 0 C / F Class E** Class 0 0 C / 48 F Class B Class C / 66 F Class F Class C / 3 F Class H Class C / 36 F Class N Class C / 39 F * IEEE Std.7. ** Used in European equipment 38

39 METLS g (silver) Silver is a soft, malleable metal with a characteristic sheen. It has the highest thermal and electrical conductivity of all metals. lcon provide shading coil material for stainless steel valves in silver. I (aluminium) Derived from the Latin LUMEN for LUM (Potassium aluminium sulphate). lightweight material that offers high strength and rigidity along with good corrosion resistance and heat dissipation. lcon provide die-cast bodies, solenoid enclosures and shading coils made from aluminium. Cu (copper) Copper is an important engineering material since it is widely used in its pure state and also in alloys with other metals. In its pure state it is the most important material in the electrical industry. It has high electrical conductivity and corrosion resistance and is easy to fabricate. It has reasonable tensile strength, controllable annealing properties and general soldering and joining characteristics. lcon provide as standard shading rings produced from Copper. CU Sn (bronze) Bronze alloys consist of copper and tin primarily and these can be known as "tin bronzes". Since phosphorus is usually added to these alloys as a deoxidising agent during casting, the tin bronzes are commercially known as "phosphor bronzes". These alloys possess desirable properties such as high strength, wear resistance, and good sea water resistance. lcon provide bodies from bronze. Fe CrNi 300 Series (8-8) ustenitic 303 is essentially low-carbon steel to which chromium has been added. It is the addition of chromium, in amounts of 8%, that adds strength and gives stainless steel its unique 'stainless', corrosion-resisting properties. The corrosion resistance, as well as other useful properties of the steel, is enhanced by the addition of other elements such as 8% nickel. lcon provide flange tubes, bodies & springs in 300 series stainless steel is essentially low-carbon steel to which chromium has been added. It is the addition of chromium, in amounts of 8%, that adds strength and gives stainless steel its unique stainless, corrosion-resisting properties. The corrosion resistance, as well as other useful properties of the steel, is enhanced by the addition of other elements such as % nickel. lcon provide valve bodies flange tubes and coil enclosures in 36L series stainless steel. 430F & 430FR Magnetic Type 430F is a solenoid grade stainless steel that has the best magnetic properties and lowest residual magnetism. Type 430FR stainless, used for corrosive service for many years, also offers improved wear resistance, higher electrical resistivity and increased hardness. lcon s plunger and top stop materials are produced using the 430F series. Basic composition 8% chromium, remainder iron. Cu Zu (brass) Brass is probably the best known of the yellow metals and it is produced in a wide variety of forms with many different characteristics and attributes. It is a basic alloy of copper and zinc and it finds many engineering applications. lcon provide forged bodies from brass this forging brass has a composition of 8% copper, % lead and 40% zinc. Keeping the World Flowing 39

40 MODES OF OPERTION / N/C Normally Closed Solenoid Operated Direct cting Solenoid Pilot Operated way, normally closed, energise to open, on/off operation (de-energise to close), with one inlet and one outlet connection. There are types of valve operation Direct cting and Pilot Operated. a) Direct cting The coil supplies all the power to open the valve and the valve will operate from zero pressure. b) Pilot Operated this can either be diaphragm or piston operated. These valves have a pilot hole which is opened/closed by the coil acting upon a plunger and diaphragm or piston used to control the main Orifice (mm). The operation relies on the media pressure difference between the inlet and outlet and a minimum operating pressure is required to operate these valves unless stated as zero. / N/O Normally Open Solenoid Direct cting Solenoid Pilot Operated way, normally open, energise to close, de-energise to open, with one inlet and one outlet connection. Can be either direct acting or pilot operated. 3/ N/C Normally Closed Valve open when energised, closed when de-energised. This valve operates on the same principle as the / N/C version except the valve has 3 connections, orices, one permanently open, one permanently closed. The use of these are for operation of actuators for large valves where single cylinder spring return system is employed. 3/ N/O Normally Open Valve open when de-energised, closed when energised. 3/ UNI Universal Valve may be used as normally closed, normally open or diversion/selector valve. / These valves are available in forms; a) Single Solenoid position, spool and sleeve type, which is based on an air pilot return mechanism. When de-energised, the valve allows one inlet and one outlet to be connected, exhausting the other inlet/outlet connection through an exhaust port. On energisation, the action reverses. b) Dual Solenoid Valves these spool and sleeve type solenoid valves are momentary contact type. When one coil is energised, one inlet is connected to one outlet, with the other inlet/outlet connection connected to an exhaust port, when the coil is de-energised and other coil energised, the action is reversed. These valves are for use on double acting cylinder applications. 40

41 MODES OF OPERTION / N/C Normally Closed Pneumatic way, normally closed, pressurise to open, de-pressurise to close with the aid of a return spring, having one inlet and one outlet connection. Can be direct acting air operated against a return spring. Note: These valves are operated via a 3 way solenoid valve which is always required. / N/O Normally Open Pneumatic way, normally open, pressurise to close, de-pressurise to open with the aid of a return spring, having one inlet and one outlet connection. Can be direct acting air operated against a return spring. Note: These valves are operated via a 3 way solenoid valve which is always required / N/C Normally Closed Motorised m way, normally closed, energise to open (slow opening) de-energise to close (quick closing) with one inlet and one outlet connection. Motor driven against a return spring. / N/O Normally Open Motorised m way, normally open, energise to close (slow closing) de-energise to open (quick opening). / N/C Normally Closed Manual Reset (Solenoid) These valves operate on the same principle as / N/C direct acting version except once the coil is energised the valve will not open until manually opened by either a lever or push reset device. / N/C Normally Closed Manual Reset (Motorised) m The operation is similar to / N/C Normally Closed Manual Reset (Solenoid) except, once the motor is energised the valve will not open till a manual reset/relay button is operated, either remote or integral to the actuator. General use is for both manual reset or safety systems where knowledge of an electrical failure is required. Keeping the World Flowing 4

42 PROTECTION CLSS, IP RTINGS & HZRDOUS RES Enclosure Protection - Non Hazardous locations, Comparison of merican Nema classification & European CENELEC IP classification Nema type & relevant tests Description Equivalent degree of protection General purpose - indoor IP30 Drip proof - indoor IP3 3 Dust and rain tight - outdoor IP4 3R Rain proof - outdoor IP4 4 Water tight and dust tight - indoor and outdoor IP6 4X Water tight, dust tight and corrosion resistant - indoor and outdoor 6 Submersible, water tight and dust tight - indoor and outdoor IP67 Industrial use, dust tight and drip proof - indoor IP 3 Oil tight and dust tight - indoor IP IP6 IP No. First number - protection again solids Second number - protection against liquids 0 No protection No protection 3 4 Protected against solid objects over 0mm Ø Protected against solid objects over mm Ø Protected against solid objects over.mm Ø Protected against solid objects over mm Ø Protected against dust-limited ingress permitted 6 Totally protected against dust 7 8 Protected against vertically falling drops of water Protected against direct sprays up to from vertical Protected against direct sprays up to 60 from vertical Protected against direct sprays from all directions limited ingress permitted. Protected against low pressure jets from all directions limited ingress permitted Protected against strong jets from all directions limited ingress permitted Protected against effects of immersion from cm - m Protected against long periods of immersion under pressure International Standards - Temperature classification IEC 79-8 & CENELEC Class Max. surface temp (ºC) Class mercian NEC Max. surface temp (ºC) T 40 T 40 T 300 T3 00 T4 3 T T TB TC TD T3 T3B T3C T4 T T 00 T 00 T6 8 T6 8 Zones & divisions - Define the likelihood of the hazard being present in potentially explosive concentrations US & CND US & CND Hazardous continuously present (>000 hrs / year) Zone 0 Hazard likely to be present Zone Division Hazard likely to be present: N.B. where the hazard is continuously present, electrcial apparatus is avoided if possible. Hazard unlikely to be present: typically only for short periods or under fault conditions (<0 Hrs/year) Fully defined in BS34 and IEC 79-0 (Guideline figures) Zone Division Hazard unlikely to be present - likely to be confined. n area adjacent to a Division area. Fully described in rticle 00 of the National Electrical Code. 4

43 SELING SOLUTIONS Nitrile (BunaN) (NBR) Trade Names: Chemigum Hycar (Zeo (Goodyear)n Chemical), Ny Syn (Copolymer), Paracril (Uniroyal), Krynac (Polysar), PerNitrilen (Mobay) This is the most widely used O-Ring elastomer. It has excellent resistance to petroleum products. Excellent compression set, tear and abrasion resistance. Suitable for air, oil, water, acetylene, kerosene, lime solutions, liquefied petroleum gases and turpentine. Nitrile / BunaN is lcon s preferred sealing solution unless otherwise stated. lcon recommends that Nitrile is used within the temperature range of -0 C to +80 C (4 F to 76 F). Please note Nitrile is not recommended for highly aromatic petroleum / gasoline s or acids. EPDM (EPR or EPDM) Excellent resistance to weathering and ozone, water and steam, with good performance in castor and some phosphate ester based fluids and poor on petroleum / gasoline. It s low and high temperature capabilities are good, having excellent resistance to set with good resilience, this low compression set provides a suitable solution for steam sealing. EPDM is suitable for temperatures above the Nitrile range. Ethylene-propylene is generally suitable for most photographic solutions as well as numerous chemical solutions. EPDM has served to replace the formerly used butyl. lcon recommends that EPDM is used within the temperature range of -0 C to +0 C (-8 F to +48 F). Please note EPDM should NEVER be used in contact with mineral based fluids or DI ester based lubricants, due to excessive swell and deterioration. When lubrication is required silicone grease or fluids should be used. *VITON (FPM FLUOROELSTOMER) It has high temperature capabilities, excellent resistance to hydraulic oils, petrol and many other chemicals. Viton O-Rings are used in automobile and other mechanical devices requiring maximum resistance to elevated temperature and to many functional fluids. Viton is a fluorocarbon elastomer. Primarily developed for handling hydrocarbons such as jet fuels, gasoline s, solvent, etc., which normally caused detrimental swelling to NBR. Viton has a high temperature range similar to ethylene propylene but is more resistant to dry heat. Viton has a rather wide range of chemical compatibility. lcon recommends that Viton is used within the temperature range of -0 C to +0 C (-4 F to +30 F). *Viton is a registered trademark of Du-Pont * PTFE / TEFLON PTFE is a fluorocarbon resin known as a disc sealing material solution where all other synthetic materials have failed. Rulon is a form of Teflon having fillers which have been added for improved mechanical properties. Teflon with fillers are considered more of a plastic than a resilient-type material. They are virtually unattacked by any fluid. PTFE provides sealing solutions for cryogenic and steam applications. lcon recommends that PTFE is used within the temperature range of -00 C to +80 C (-38 F to + 36 F). *TEFLON is a registered trademark of Du-Pont. It must be noted that PTFE sealing will allow slight let-by. Silicone This elastomer provides high and low temperature solutions under certain conditions for numerous applications (it must be noted that silicone is not suitable for steam applications). It can handle hydrogen peroxide and some acid solutions. Silicone s retention of properties at high temperatures is superior to other elastic materials. lcon recommends that Silicone is used within the temperature range of -6 C to +0 C (-8 F to +48 F). It must be noted that Silicone has poor tensile strength, tear resistance and abrasion resistance. Neoprene Neoprene is commonly used for refrigeration systems sealing as an external seal. Suitable for alcohol, mild acids, water, air, ammonia, argon gas and other gases. lcon recommends that Neoprene is used within the temperature range of -0 C to +90 C (-4 F to +94 F). Consideration lthough lcon state a temperature range for it s elastomers, limitations are also dependent on their specific function within the valve. n example of this would be with a diaphragm and an O-Ring at a low temperature, both will stiffen, however, the sealing capabilities of the diaphragm will be reduced but the O-Ring, of similar material, which stiffens at low temperature may still perform its sealing function. lcon recommend that temperatures down to -0 C (-4 F) can be considered tolerable. Elastomers such as low temperature EPDM must be selected for use below this temperature along with the application. These can extend the low limit to approximately minus -40 C (-40 F) depending on specific usage. Generally the upper temperature limit for elastomers is +00 C ( F). Viton and EPDM can support higher temperatures up to +0 C depending upon application. When applications arise that are below or above the temperature capabilities of lcon s elastomers we can provide PTFE / PCTFE sealing solutions. These unique chemical-resistant materials can be used from -00 C to +80 C (-38 F to +36 F) when used considering specific design constraints. Keeping the World Flowing 43

44 Solenoid Enclosures S4 Type Enclosure Protection Class IP0 External Material: Pressed steel Powder Coated Electrical Connection: ½"NPT conduit hub with 8" leads (NEM equivalent protection class) Winding insulation Class H S7 Type Enclosure Protection Class IP6 Material: Nylon Electrical Connection: DIN Plug to ISO 4400 Standard Enclosure for /, Universal Namur Valves Winding insulation Class F This enclosure conforms to IP6 when correct plug seal gasket is fitted. 44

GTV Series High Pressure Control Valves

GTV Series High Pressure Control Valves For primary and secondary shut off of fuel control lines Keeping the World Flowing Contents Section Page Technical Specification 3 ¾" & " 2-Way Poppet Valve 4 ¾" & " 3-Way Poppet Valve 5 /2", 2" & 3" 2-Way

More information

Poppet Valves Series. Keeping the World Flowing

Poppet Valves Series. Keeping the World Flowing Poppet Valves 750 Series Keeping the World Flowing Contents Section Page Introduction 750 Series Poppet Valve Pilot operated 4 /4 to / Pilot operated 5 /4 to Pilot operated 6 Pilot operated 7 /4 to / Pilot

More information

Your Global Source for Today s Most Popular Solenoid Valves

Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International

More information

Poppet Valves Series

Poppet Valves Series Poppet Valves 750 Series ontents Section Page Introduction 750 Series Poppet Valve Pilot operated 4 /4 to / Pilot operated 5 /4 to Pilot operated 6 Pilot operated 7 /4 to / Pilot solenoid operated 8 /4

More information

PROCESS & AUTOMATED VALVES

PROCESS & AUTOMATED VALVES Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline

More information

Poppet Valve Catalogue

Poppet Valve Catalogue Poppet Valve Catalogue Poppet Valves 750 series pilot operated 750 series pilot solenoid operated 750 series plunger or lever roller operated Redefining Flow Control Contents Section Page Introduction

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT FEATURES Compact design, high fl ow rates Visual position indicator standard For temperatures from 22 F to +430 F / -30 C to 221 C Working pressures up

More information

Air Actuated 3-Way Ball Valves T-Port, Lead Free Brass, Full Port 1/4 to 2 NPT

Air Actuated 3-Way Ball Valves T-Port, Lead Free Brass, Full Port 1/4 to 2 NPT Air Actuated 3-Way Ball Valves T-Port, Lead Free Brass, Full Port 1/4 to 2 NPT SERIES Features Full Port Lead Free Brass Diverter Valve Spring return or double acting actuators Ball Valve direct mounted

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way valve program is especially to

More information

ROM and ROMpak Range. Quarter-turn Direct Drive Electric Actuators. Established Leaders in Actuation Technology

ROM and ROMpak Range. Quarter-turn Direct Drive Electric Actuators. Established Leaders in Actuation Technology ROM and ROMpak Range Quarter-turn Direct Drive Electric ctuators Established Leaders in ctuation Technology Contents Section Page Product Overview 3 Features of the ROM and RM Range 4 Mechanical and Electrical

More information

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT SERIES Features Spring Return or Double Acting Actuators Lead Free Brass Ball Valve with ISO5211 direct mounting Full port design

More information

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT Features Full Port direct mount 316 SS ball valve Functions as a diverter valve 1000 PSI working pressure at 100 F (38 C) Visual valve position

More information

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT Features Industrial quality miniature actuator Full Port direct mount 3-way stainless steel ball valve

More information

Economy Air Operated Brass Ball Valve

Economy Air Operated Brass Ball Valve Type: PA1101E Type: PA1111E Type: PA1121E Pneumatic actuator direct mounted Actuator fitted via mounting kit Actuator fitted via TSM stem extension Pneumatic Actuator features: Rack and pinion construction

More information

Motorised Valve Range

Motorised Valve Range Motorised Valve Range Contents Motorised Valves... 2 Fail Safe Motorised Valves for Bio Diesel and Bio Fuels... 2 Fail Safe Motorised Valves... 3 Motor-Open Motor-Close... 6 Electro-Thermal Links... 9

More information

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65. NAMUR 1/4 & 1/2 High Flow valves for actuator control Catalogue 4921/GB INDEX General Information...page 2 G 1/4 Series...page 4 G 1/2 Serie...page 6 Accessories...page 8 TECHNICAL DATA Function : Manual

More information

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2) ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2) BRASS OR STAINLESS STEEL BODY POLYMER OR METAL ACTUATOR HERION USA Inc. Valve Technology and Systems Brochure N-285 Multi-Accessory Polymer Head versions Increased

More information

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System Remote Process Actuation Control System AirLINE - Rockwell 1734 Type 8644 can be combined with... Fully compatible with Rockwell 1734 Point I/O System Combination of Fieldbus, pilot valves and I/O modules

More information

2/2-way assisted lift operated solenoid valve type EV250B

2/2-way assisted lift operated solenoid valve type EV250B MAKING MODERN LIVING POSSIBLE Data sheet 2/2-way assisted lift operated solenoid valve type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way valve

More information

3/2-way Solenoid Valve for pneumatics

3/2-way Solenoid Valve for pneumatics 656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511

More information

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED BC 4.3 Gas Tight Dampers GTD-GB40-B-E Table Of Contents S. No Description Page No 1 Gas Tight Damper with Electric Drive 1 2 Electric Drive - Details 2-3 3 Gas Tight Damper with Pneumatic Drive 4 4 Pneumatic

More information

2/2 Pressure operated valves

2/2 Pressure operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54

More information

Angle Seat Valve /2" up to 3"

Angle Seat Valve /2 up to 3 1/ up to up to 428 F Pneumatically operated angle seat valve for the control of neutral and aggressive gases, liquids and steam. Compact design For temperatures from -22 F up to +428 F Working pressure

More information

2/2- and 3/2-way solenoid valve for aggressive fluids

2/2- and 3/2-way solenoid valve for aggressive fluids 2/2- and 3/2-way solenoid valve for aggressive fluids Type 0121 can be combined with Direct-acting, media-separated valve with diameter of up to DN 8 Maintenance-free pivoted armature technology Vibration-proof,

More information

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Remote Process Actuation Control System AirLINE - Siemens ET 200S Remote Process Actuation Control System AirLINE - Siemens ET 200S Type 8644 can be combined with... Fully compatible with Siemens ET 200S Combination of Fieldbus, pilot valves and I/O modules High flexibility

More information

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems 66 /2-way Miniature Rocker Solenoid Valve for pneumatic systems Direct-acting High cycling rate Reduced power consumption CNOMO and Bürkert flange interface Type 66 can be combined with TEX Ex ia on request

More information

Direct-acting 2/2- or 3/2-way pivoted armature valve

Direct-acting 2/2- or 3/2-way pivoted armature valve 0330 Direct-acting 2/2- or 3/2-way pivoted armature valve Direct-acting, media-separated valve with diameter of up to DN 5 Maintenance-free pivoted armature technology Vibration-proof, block screwed coil

More information

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems 66 /2-way Miniature Rocker Solenoid Valve for pneumatic systems Direct-acting High cycling rate Reduced power consumption CNOMO and Bürkert flange interface Type 66 can be combined with TEX Ex ia on request

More information

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base 3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base Sub-base Direct-acting, normally closed and normally open Brass and stainless steel body Electrical cable plug Form A With or without manual override

More information

Solenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections

Solenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections /-way Diaphragm Valve with plastic body, pneumatically operated, 1/ 3 with true union 3 with fl ange pplications with aggressive media Flow optimised body with zero dead volume Self draining installation

More information

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves Sc h rader Bellows 2 & 3-Way, Inline, Manifold & Stacking Direct cting Solenoid Valves INDEX PGE Features Inline Valves... 3 Stacking Valves... 4 Manifold Valves... 5 Valve Model Number System... 6 Solenoid

More information

Servo-operated 2/2-way solenoid valves Type EV220A

Servo-operated 2/2-way solenoid valves Type EV220A Data sheet Servo-operated 2/2-way solenoid valves Type is a compact servo-operated 2/2-way solenoid valve program, especially designed for use in machines and equipment with limited space. Features and

More information

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated ICOS - /, / or 5/ Exia poppet valves > > Port size: /... / (ISO G/NPT) /... (Flanged) > > Zone 0, Exia solenoid pilot operated valve > > Safety integrity level and > > Reliable and long life, ideal for

More information

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C) Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.

More information

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2 2/2-way Compact Solenoid Valve, G 1/4 - G 1/2 Stainless steel body Type 6027 Compact can be combined with Direct-acting, normally closed Brass and stainless steel body Electrical connection cable plug

More information

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED BC 4.2 Tunnel Ventilation Dampers TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S Type : Tunnel Ventilation Fire Damper Model : TVFD-GB-40-B;TVFD-SB-40-B Fire Rating :

More information

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

Solenoid valves, 2/2-way servo-operated type EV220B 6-22 MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves, 2/2-way servo-operated type EV220B 6-22 EV220B 6-22 is a direct servo-operated 2/2-way solenoid valve program with connections from 1/4 to 1. This

More information

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

High Flow Valve Actuation Range. NAMUR Valves G1/4 & G1/2 Piped Valves G1/4 & G1/2 Banjo Valves G1/8 & G1/4 31-37 High flow NAMUR valves G1/ and G1/ aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding High Flow Valve Actuation

More information

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65. Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx

More information

Technical Principles of Valves

Technical Principles of Valves Technical Principles of Valves Symbols and Circuit Functions Symbol to DIN-ISO 1219 The circuit function illustrations are defined to the DIN-ISO 1219 Standard. These can be used to show other switching

More information

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504 Data sheet Solenoid valves 2/2-way direct-operated Type EV210B February 2002 DKACV.PD.200.A5.02 520B1504 closed Type EV210B NC for neutral liquids and gases DN 1.5-25 B - G1 Features Technical data 1 )

More information

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65 2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65 Standard valve body Type 2000 can be combined with Short valve body High flow rate and long life cycle Very high cycle

More information

Solenoid valves 2/2-way servo operated type EV220B 15 50

Solenoid valves 2/2-way servo operated type EV220B 15 50 MAKING MODERN LIVING POSSIBLE Datasheet Solenoid valves 2/2-way servo operated type EV220B 15 50 EV220B 15 50 is a universal indirect servo-operated 2/2-way solenoid valve program. Valve body in brass,

More information

3-Way Solenoid Valve - Direct Acting

3-Way Solenoid Valve - Direct Acting 3-Way Solenoid Valve - Direct Acting General application valves for dry or lubricated air, neutral gases and liquids Description: Applications: 3-Way Solenoid Valve - Direct Acting - Normally Closed. Coil

More information

Control Valve Specifications

Control Valve Specifications Control Valve Specifications Available in two-way, three-way and four-way configuration and with port sizes from 10-32UNF through to 1/2"NPT. The N2V & N3V1 offering is a direct acting solenoid poppet

More information

Solenoid valve Types EV220B 15 - EV220B 50

Solenoid valve Types EV220B 15 - EV220B 50 Solenoid valve Types EV220B 15 - EV220B 50 EV220B 15 EV220B 50 is a universal indirect servo-opera ted 2/2-way solenoid valve program. Valve body in brass, dezincification resistant brass and stainless

More information

SKINNER Intrinsically Safe Series Four-Way

SKINNER Intrinsically Safe Series Four-Way SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air

More information

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe 1/2 to 4 inch Pipe Features Direct mount ISO5211 Full Port stainless steel ball valve 2-piece ANSI Class 150 flanged body 275 PSI working pressure at 100 F (38 C) Highly visual dome style valve position

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet Type 52 2/2-way solenoid valve NC - Valve normally closed (as standard) NO - Valve normally open (as option) Direct operated piston design valve. No differential pressure is necessary

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical. qwer Normally Closed or Normally Open and Hot Water Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Handle the challenges of high-temperature fluids. PTFE and EPDM discs,

More information

Servo piston operated 2/2-way solenoid valves for steam Type EV245B

Servo piston operated 2/2-way solenoid valves for steam Type EV245B Data sheet Servo piston operated 2/2-way solenoid valves for steam EV245B EV245B is a servo piston operated 2/2-way solenoid valve for use in steam applications. The servo piston operated design with PTFE

More information

Solenoid valve Types EV220B 15 - EV220B 50

Solenoid valve Types EV220B 15 - EV220B 50 Data sheet Solenoid valve Types EV220B 15 - EV220B 50 EV220B 15 EV220B 50 is a universal indirect servo-opera ted 2/2-way solenoid valve program. Valve body in brass, dezincification resistant brass and

More information

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8 to 2 1/2 NPT. Features. Construction. 4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide

More information

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG Productinformatie A.U.K. MÜLLER GMBH & CO. KG Description 14.025.126 series water inlet valves are 2/2-way solenoid valves with an orifice size of 25 mm. They have been developed to control potable water

More information

Servo-operated 2/2-way solenoid valves for steam Type EV225B

Servo-operated 2/2-way solenoid valves for steam Type EV225B Data sheet Servo-operated 2/2-way solenoid valves for steam EV225B EV225B is a servo-operated 2/2-way solenoid valve for use in steam applications. The design is based on a PTFE diaphragm concept, ensuring

More information

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve Angle-seat Valve System for continuous control Type 8802/2300 electro-pneumatically operated angle-seat valve + = TWO YEAR WARRANTY on this valve system Burkert 8802 continuous control valve + = 2300 series

More information

2/2-way Globe Valve for media up to +180 C, DN

2/2-way Globe Valve for media up to +180 C, DN 2/2-way Globe Valve for media up to +180 C, DN 10-100 Compact globe valve version Flange, threaded and welded ports as standard Stainless steel 316L valve body vailable with flow direction below and above

More information

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe SERIES Features Industrial quality miniature actuator Industrial grade True Union ball valve Visual valve position indicator

More information

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1 SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1 NC 2/2 Series 220 FEATURES Small compact d valves particularly designed for hot water and steam, compatible with the seal materials

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm / or 3/-way Solenoid Valve, with pivoted armature and isolating diaphragm Type 0330 can be combined with Lockable manual override as standard For liquid, gaseous and aggressive media Long service life,

More information

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4 NPT. Features. Construction. Direct Acting Direct Mount Pilot Valves Brass or Stainless Steel Bodies /" NPT / 83 Direct Mount Features NAMUR direct mount version of the rugged, dependable 83 Series valves Direct acting, high flow

More information

3-Way Brass Ball Valves L or T Port Design, 400 PSI WOG 1/4 to 3 NPT

3-Way Brass Ball Valves L or T Port Design, 400 PSI WOG 1/4 to 3 NPT 3-Way Brass Ball Valves L or T Port Design, 400 PSI WOG 1/4 to 3 NPT SERIES Features Standard Port 3-way L or T flow path Four seat design allows for full pressure at any port Hand lever operator Actuator

More information

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function DIRECTIONL CONTROL VLVES Directional Control Valves PS-SERIES 3/2, 5/2 and 5/3-way Single and double acting control Long lifespan Low energy consumption Standard manual override Wide range of operating

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

Assisted lift operated 2/2-way solenoid valves Type EV251B

Assisted lift operated 2/2-way solenoid valves Type EV251B Data sheet Assisted lift operated 2/2-way solenoid valves Type EV251B EV251B with assisted lift is especially suitable for applications such as closed systems with low and fluctuating pressure conditions

More information

CONDENSED CATALOG CC

CONDENSED CATALOG CC CONDENSED CATALOG CC-2004 THE COMMITMENT CONTINUES Fluid Power is our business. It is our only business, so we have to be good at it. Since its beginning in 1949, Versa has maintained its commitment to

More information

Valves For Process Industry. Engineered Pneumatic Solutions.

Valves For Process Industry. Engineered Pneumatic Solutions. Valves For Process Industry Engineered Pneumatic Solutions www.pneumatrol.com Pneumatrol Limited (formerly RGS Davis) is a specialist manufacturer accredited to ISO 9001. Operating from its headquarters

More information

2-Way/2 Position Valves

2-Way/2 Position Valves 4 2-Way/2 Position Valves Two-way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply Normally Closed (NC) Fluid is shut off when

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

2/2-way Globe Valve for media up to +180 C, DN

2/2-way Globe Valve for media up to +180 C, DN 2/2-way Globe Valve for media up to +180 C, DN 10-100 Compact globe valve version Flange, threaded and welded ports as standard Stainless steel 316L valve body Available with flow direction below and above

More information

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT 1/4 to 3 NPT Features Direct mount ISO5211 Full Port stainless steel ball valve 3-piece swing out body designed for easy maintenance 1000 PSI working pressure at 100 F (38 C) Highly visual dome style valve

More information

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe 2 to 6 Pipe Features Direct mount wafer butterfly valve with ISO5211 mount 3-layer epoxy coated ductile iron body with 316 SS disc Unique wave line seat reduces torque and extends seal life Visual valve

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT Normally Closed or Normally Open Hot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT 2/2 Features Handle the challenges of high-temperature fluids PTFE and EPDM discs, stainless steel

More information

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE FEATURES The bronze ZEUS valve is intended for the automatic shutoff of networks of fluids. The full-bore inclined-seat body and the excellent flow-rate coefficients allow for very low pressure drops.

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

Valve Reference C5. Valve Reference C6. 4-Way. 4-way direct acting

Valve Reference C5. Valve Reference C6. 4-Way. 4-way direct acting Valve Reference C5.86 3.25.53 1.31 1.62 E 3.25 4.31 2.37 2.56 1.73 2.24 P 1/4 Thru Bolt Holes 4 PLC s 2.69 4-way direct acting V933xx: Normally Closed-Normally Closed v935xx: Normally Closed-Normally Open

More information

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B Pilot operated port solenoid valve (general purpose valve) P/P Series NC (normally closed) type, NO (normally open) type Port size: Rc/4 to Rc Piston structure Refer to Ending 7 for more details. JIS symbol

More information

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe with EPS Positioner

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe with EPS Positioner 2 to 6 Pipe with EPS Positioner Features EPS- Electronic Positioning System with 4-20mA/0-10V input Lug body valve with ISO5211 direct mount actuator 3-layer epoxy coated ductile iron body with 316 SS

More information

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk Black Teknigas Powerseat Eco Gas Safety Shut-Off Valve Technical, and Maintenance Details WattsIndustries.co.uk Safety shut off valves for gas, air and oil EN161 approved; EC certificated Robust construction

More information

Solenoid Valves. Product Information. It s all at Albion

Solenoid Valves. Product Information. It s all at Albion Solenoid Valves Product Information It s all at Albion General Information SLP 2/2 WAY SOLENOID VALVE SERIES A:Product Applications. SLP 2/2 way series solenoid valves are commonly used actuators in automation

More information

2-way pilot operated solenoid valves for water, hot water and steam. Catalogue 8658/GB December 1999

2-way pilot operated solenoid valves for water, hot water and steam. Catalogue 8658/GB December 1999 -way pilot operated solenoid valves for water, hot water and steam Catalogue 88/GB December 999 88/GB Technical specifications General description The Water Valves are diaphragm operated valves and require

More information

Air Operated 3 Way Brass Ball Valve

Air Operated 3 Way Brass Ball Valve Type: PA1302 Type: PA1312 Type: PA1322 Pneumatic actuator direct mounted Actuator fitted via mounting kit Actuator fitted via stem extension Pneumatic Actuator features: Rack and pinion construction Hard

More information

Direct-acting 2/2-way plunger valve

Direct-acting 2/2-way plunger valve Direct-acting 2/2-way plunger valve Type can be combined with Direct-acting and compact valve up to diameter of DN 6.0 Vibration-proof, bolted coil system Increased leak-tightness with welded plunger guiding

More information

2/2-way Solenoid Valve for liquids and gases

2/2-way Solenoid Valve for liquids and gases 2/2-way Solenoid Valve for liquids and gases Type 6213EV can be combined with... Coupled spring diaphragm system opened without differential pressure Waterhammer free and low noise HP00 version with increased

More information

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel CATALOGUE > Release 8.8 > Series A solenoid valves Series A directly operated solenoid valves /-way - Normally Closed (NC) and Normally Open (NO) 3/-way - Normally Closed (NC) and Normally Open (NO)»»

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm 2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm Lockable manual override as standard For liquid, gaseous and aggressive media Long service life, even in non-lube conditions

More information

3-Way Lead Free Brass Ball Valves Full Port, L or T Flow Path, 400 PSI CWP 1/4 to 2 NPT

3-Way Lead Free Brass Ball Valves Full Port, L or T Flow Path, 400 PSI CWP 1/4 to 2 NPT 3-Way Lead Free Brass Ball Valves Full Port, L or T Flow Path, 400 PSI CWP 1/4 to 2 NPT SERIES Features FULL PORT 3-way L or T flow path Functions as a diverter, selector or mixing valve Four ball seat

More information

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT Valve program for small and medium flows: VDHT 3/8 E 2/2 VDHT 1/2 E 2/2 VDHT 3/8 EA 2/2 VDHT 1/2 EA 2/2 Valve program

More information

DIECT MOUNT CTUTO VLVES LUMINUM CONSTUCTION SEIES C5 NMU General Description The Versa C5 NMU mount control valve is a high flow, 5-port, solenoid/pil

DIECT MOUNT CTUTO VLVES LUMINUM CONSTUCTION SEIES C5 NMU General Description The Versa C5 NMU mount control valve is a high flow, 5-port, solenoid/pil NMU DIECT MOUNT PNEUMTIC CTUTO VLVES I VLVES FO INDUSTY SINCE 1949 BULLETIN NMce-2004 SOLENOID CTUTION 1/4 NPT or G1/4 DIECT MOUNT TO MNY DIFFEENT CTUTOS 10 YE WNTY C5 Series: E5 Series: 3-way or 4-way,

More information

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE CHARACTERISTICS The ZEUS bronze pneumatic actuated valve is dedicated to the automatic shut-off of fluid pipework. The full bore angle body and the great flow rates permit to have very limited pressure

More information

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50 2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, 10-50 (2652) (2655) 2 or ball valve Pneumatic actuator Compact design Visual position indicator Types 2652/2655 can be

More information

STC Manual & Actuated Process Valves

STC Manual & Actuated Process Valves STC Manual & Actuated Process Valves Fine Quality Precision Engineered Excellent Prices Advanced Design connects fluid power to industrial automation Table of Contents STC Valve Numbering System.......2

More information

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15 MINI-SOLENOID VALVES ISO 58 (CNOMO, size 5) interface direct operated, pad mounting body connector size 5 NC / Series 0 FEATURES Compact, monobloc solenoid pilot valve with spade-plug connector type EN

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

/2-way piston valves

/2-way piston valves > > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring

More information

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions Data sheet Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions EV220W is a range of compact indirect servo- operated 2/2 way solenoid valves with connections

More information

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 316SS diverter valve Polyamide IP67 weatherproof enclosure with UV protection Multi-voltage

More information