INTEGRAL Self-Protected Combination Motor Controllers

Size: px
Start display at page:

Download "INTEGRAL Self-Protected Combination Motor Controllers"

Transcription

1 INTEGRAL Self-Protected Combination Motor Controllers Class 8539 CONTENTS Schneider Electric Brands Description Page Product Descriptions Selection Application and General Information Specifications Wiring Diagrams Dimensions

2 Schneider Electric All Rights Reserved 0/00

3 Product Description COMBINATION MOTOR CONTROL IN ONE COMPACT PACKAGE! The INTEGRAL Self-Protected Combination Motor Controller (CMC) combines all the functions of a disconnect, circuit breaker, contactor, and overload relay in a coordinated motor controller. A wide variety of easy-toinstall auxiliary blocks and interface modules provides powerful communication and control capabilities. As much as 60% less panel space is required by the INTEGRAL CMC as compared to traditional combination motor control circuit installations. In addition, installation and wiring time is dramatically reduced simply snap the INTEGRAL onto a 35 mm DIN rail and connect load and line side wires. Integral 8 The entire family of INTEGRAL CMCs have proven their reliability and effectiveness in thousands of applications worldwide. By installing the INTEGRAL Self-Protected CMC, you are implementing the latest in motor control and protection technology, and assuring the lowest installed cost of any motor control scheme. Features Integral 32 Non-reversing and reversing combination motor controllers available in 8, 32, or 63 ampere ratings. NEMA Type and 2 enclosed combination motor controllers and open style combination motor controllers both available. Current-limiting short-circuit protection provides 42 ka interrupt rating. UL listed as a Type E combination motor controller. UL verified to meet Type 2 coordination protection per IEC Meets Total Coordination requirements of IEC no damage to contactor or overload relay, and no welding of contacts after interruption of short-circuit faults. Padlockable isolation knob. Minimum.5 million operation life expectancy. Proven reliability even after exposure to multiple short-circuit faults! Control direct from PLC or PC with optional interface modules. Integral 63 0/ Schneider Electric All Rights Reserved 3

4 Product Description INTEGRAL 8 INTEGRAL 32 Rated Operational Current for AC-3 Duty LDLB030 LD5LB LBLB03P LBLB03P 8 A 32 A Rated Breaking Capacity 42 KA at 480 Vac 42 KA at 480 Vac LDLC030 LD4LC030 LD5LC LBLC03M LBLC03M LBLC03M Approvals ASTA, BS, CSA, DEMKO, IEC, NEMKO, SEMKO, UL, VDE ASTA, BS, CSA, DEMKO, IEC, NEMKO, SEMKO, UL, VDE Number of Poles 3 3 Protection Module LBLB03P LBLC03M Magnetic Protection Fixed, 5 times maximum thermal current Adjustable, 6 to 2 times maximum thermal current Overload Protection 0. to 0.6 A: P0 0.6 to 0.25 A P to 0.4 A P to 0.4 A M to 0.63 A P to 0.63 A M to.0 A P to.0 A M05.0 to.6 A P06.0 to.6 A M06.6 to 2.5 A P07.6 to 2.5 A M to 4.0 A P to 4.0 A M to 6.0 A P0 4.0 to 6.3 A M0 6.0 to 0.0 A P 6.3 to 0.0 A M 0.0 to 6.0 A P7 0.0 to 6.0 A P7 2.0 to 8.0 A P2 6.0 to 25.0 A M to 32.0 A M Schneider Electric All Rights Reserved 0/00

5 Product Description INTEGRAL 63 Rated Operational Current for AC-3 Duty Rated Breaking Capacity Approvals Number of Poles 3 Protection Module Magnetic Protection Overload Protection 63 A 42 KA at 480 Vac LDLC030 LD4LC030 LD5LC LBLC03M LBLC03M LBLC03M ASTA, BS, CSA, DEMKO, IEC, NEMKO, SEMKO, UL, VDE LBLD03M Adjustable, 6 to 2 times maximum thermal current 0.0 to.0 A M6.0 to 8.0 A M2 8.0 to 25.0 A M to 32.0 A M to 40.0 A M to 50.0 A M to 63.0 A M6 0/ Schneider Electric All Rights Reserved 5

6 Selection To order an INTEGRAL CMC, complete these four steps: LDLB030 LD5LB0 LD4LC030 LD5LC030 LD4LD030. Select the correct combination motor controller from Table A (open) or Table B (enclosed). 2. Complete the catalog number by adding the coil voltage code from Table Choose the appropriate protection module from Table For enclosed combination motor controllers only, select any desired INSTA-KITS or factory modifications from Table on page 20. For factory modification, add the form number to the end of the catalog number. Table A: Open Style INTEGRAL CMC Base Unit Selection Table Continuous Current Rating Maximum 3-Phase HP Rating With Isolator Without Isolator Amperes 230 V 460 V 575 V Catalog Number Catalog Number Non-Reversing LDLB030* N/A LD4LC030* LDLC LD4LD030* LDLD030 Reversing LD5LB0* N/A LD5LC030* N/A LD5LD030* N/A Table B: Enclosed INTEGRAL CMC Selection Table Continuous Current Rating Maximum 3-Phase HP Rating Type Enclosure Type 2 Enclosure Amperes 230 V 460 V 575 V Catalog Number Catalog Number Non-Reversing LEUI846 LEUI LEUI3246 LEUI LEUI6346 LEUI6347 Reversing LE2UI846 LE2UI LE2UI3246 LE2UI LE2UI6346 LE2UI6347 Complete the catalog number by adding the voltage code from Table 2 Table 2: Coil Voltage Codes INTEGRAL I8 I32 I63 Control Voltage Frequency Hz B E F - M U Q N BC D K FC LC MC - - N S DC BD B E F - M U Q N BC D FC FC MC MC - - Q S DC BD ED FD B E F - M U Q N BC CE K FC LC MC - - Q S DC BD ED FD INTEGRAL Base Units ordered with DC voltage code (BD, ED or FD) are shipped with LL*080*D Voltage Converter Module already installed. Open Product Enclosed Product Open INTEGRAL CMC Dimensions page 48 Enclosed INTEGRAL CMC Dimensions page 5 File E6487 CCN NKJH NKJH7 File LR Class File E63364 CCN NKJH NKJH7 File LR Class Schneider Electric All Rights Reserved 0/00

7 Selection LBLB03P05 LBLC03M22 LBLD03M57 Table 3: Overload Protection Modules (Class 0, Ambient Compensated) Thermal Setting Range, Amperes c For 8 Ampere models Magnetic Setting Range, Amperes Standard Module with Thermal & Magnetic Trip Catalog No. c Thermal settings are based on motors with a service factor (S.F.) of.0. Specifications Magnetic only Module LBLB03P0 N/A LBLB03P02 N/A LBLB03P03 N/A LBLB03P04 N/A LBLB03P05 N/A -.6 LBLB03P06 N/A LBLB03P07 N/A LBLB03P08 N/A 4-6 LBLB03P0 N/A 6-0 LBLB03P N/A 0-6 LBLB03P7 N/A 2-8 LBLB03P2 N/A For 32 Ampere models LBLC03M03 LB6LC03M LBLC03M04 LB6LC03M LBLC03M05 LB6LC03M LBLC03M06 LB6LC03M LBLC03M07 LB6LC03M LBLC03M08 LB6LC03M LBLC03M0 LB6LC03M LBLC03M LB6LC03M LBLC03M7 LB6LC03M LBLC03M22 LB6LC03M LBLC03M53 LB6LC03M53 For 63 Ampere models LBLD03M22 LB6LD03M LBLD03M53 LB6LD03M LBLD03M55 LB6LD03M LBLD03M57 LB6LD03M LBLD03M6 LB6LD03M6 Operating Positions: UL Listed and CSA certified Conforms to IEC standards Shock resistance - 8 g (Duration of impulse: ms) Vibration resistance - 3 g (5 to 50 Hz) AC control circuit temperature limits: Storage -40 to +76 F/-40 to +80 C Rated voltage Vac Operation - to +04 F/-25 to +70 C Rated thermal current - 8 A (INTEGRAL 8), 32 A (INTEGRAL 32), 63 A (INTEGRAL 63) Interrupting current at 480 Vac: 42 ka ms Fixed magnetic trip is set at approximately 5 times full load current (FLC) INTEGRAL 8 INTEGRAL 32 INTEGRAL Mechanical life: 20 million operations 0 million operations 5 million operations 90 Operating current of magnetic trip is approximately 5 times maximum thermal trip (non-adjustable setting) File E6487 CCN NKJH NKJH7 File LR Class / Schneider Electric All Rights Reserved 7

8 INTEGRAL 8 Accessories O LLB09 LLB00 O LD5LB LLB07 LLB00 LLB02 LLB03 O LLB02 LDLB LLB05 LLB034 LLB03 LLB Schneider Electric All Rights Reserved 0/00

9 INTEGRAL 8 Accessories Auxiliary Contact Blocks for the INTEGRAL 8 CMC For Use On Mounting Location Type and Number of Contacts per Block Contact Type Catalog Number Right Side Block of 5 instantaneous contacts 3 signal contactor state 2 signal tripped status 2 N/O + N/C N/O + N/C LLB05 LDLB03FC + LBLB03P0 LD or LD5 LD LD5 Right Side Right Side Left or Right Side Block of 3 instantaneous contacts 2 signal contactor state signal tripped status Block of 3 instantaneous contacts 2 signal contactor state signal tripped status Complementary auxiliary block signal contactor state N/O + N/C N/O N/O + N/C N/C LLB07 LLB09 N/C LLB00a Left Side 2 signal operating handle not in Auto position 2 N/O LLB03 Left Side 2 signal operating handle not in Auto position N/O + N/C LLB03 Left Side Left Side Left Side Left Side Block of 3 instantaneous contacts 2 signal operating handle not in Auto position 2 signals tripped on short circuit status Block of 3 instantaneous contacts 2 signal operating handle not in Auto position 2 signals tripped on short circuit status Block of 5 instantaneous contacts 3 signal contactor state 2 signal operating handle not in Auto position Block of 5 instantaneous contacts 3 signal contactor state 2 signal operating handle not in Auto position 2 N/O N/O + N/C N/O + N/C N/O + N/C 2 N/O + N/C 2 N/O 2 N/O + N/C N/O + N/C LLB034 LLB034 LLB02 LLB02 a Use of auxiliary contact LLB00 requires combination with contact block LLB05, LLB02, LLB07, or LLB09. File E6487 CCN NKJH NKJH7 File LR Class / Schneider Electric All Rights Reserved 9

10 INTEGRAL 32/63 Accessories O LLC020 RESET LLC02 LLC03 LD5LC,LD LLC07 LLC00 LLC02 LLC052 O LLC030 (LD4) LLC030 (LD4) LDLC,LD LD4LC,LD LLC00 LLC00 LLC Schneider Electric All Rights Reserved 0/00

11 INTEGRAL 32/63 Accessories Auxiliary Contact Blocks for the INTEGRAL 32/63 CMC For Use On Mounting Location Type and Number of Contacts per Block Contact Type Catalog Number Right Side Block of 6 instantaneous contacts 3 signal contactor state signal tripped on short circuit signal tripped signal not in Auto position 2 N/O + N/C N/O-N/C (form C contact) N/O-N/C (form C contact) N/O-N/C (form C contact) LLC00 LLC030 LD, LD4 or LD5 Right Side Right Side Block of 5 instantaneous contacts 3 signal contactor state signal tripped on short circuit signal tripped Block of 4 instantaneous contacts 3 signal contactor state signal tripped 2 N/O + N/C N/O N/O 2 N/O + N/C N/O or N/C, User Selectable LLC02 LLC025 Right Side Block of 3 instantaneous contacts 3 signal contactor state 2 N/O + N/C LLC020 Left or Right Side Complementary auxiliary block signal contactor state N/C LLC00q LD4 Left Side Block of control circuit isolation contact N/O LLC030 Left Side Block of 3 instantaneous contacts 3 signal contactor state 2 N/O + N/C LLC02 LD5 Left Side Block of 2 control circuit isolation contact 2 N/O LLC03q q See table below. LLC02 Complementary blocks LLC00 and LLC03, as well as LLC052** reset modules and LLC07** trip modules on page 2 must be used with an additional auxiliary block. This following table shows all allowable combinations. Possible Combinations of Auxiliary Contact Blocks for the INTEGRAL 32/63 CMC LLC00 LLC07** LLC052* LLC03 LLC00 Block of 6 auxiliary contacts Right Side LLC02 Block of 5 auxiliary contacts Right Side f f LC4LC030+ LBLC03M22+ LLC030+ LLC00+ LLC070F LLC025 Block of 4 auxiliary contacts Right Side LLC02 Block of 3 auxiliary contacts Left Side t t f Only one attachment may be added -- either LLC00 or LLC052 t Only one attachment may be added -- either LLC00 or LLC03 File E6487 CCN NKJH NKJH7 File LR Class / Schneider Electric All Rights Reserved

12 INTEGRAL 32/63 Accessories O LLC020 RESET LLC02 LLC03 LD5LC,LD LLC07 LLC00 LLC02 LLC052 O LLC030 (LD4) LLC030 (LD4) LDLC,LD LD4LC,LD LLC00 LLC00 LLC Schneider Electric All Rights Reserved 0/00

13 INTEGRAL 32/63 Accessories The shunt and undervoltage trip modules are for use with any 32 A or 63 A INTEGRAL CMC fitted with either an LLC00 or LLC02 add-on block. Shunt and Undervoltage Trip Modules Description Trip Specifications Catalog Number Time Delay (0.2 seconds) LLC070k LLC070F Undervoltage Trip Module Instantaneous LLC072k Shunt Trip Module Instantaneous LLC07k k Complete the catalog number with the letter shown below for the required coil voltage Volts Hz B E F - M U Q N N 60 Hz B E F F M M Q - N The remote reset modules are for use with any 32 A or 63 A INTEGRAL CMC fitted with either an LLC00 or LLC02 add-on block. Remote Reset Modules Description Control Voltage Catalog Number 24 V 50/60 Hz LLC052B LLC052F 42 V 50 Hz 48 V 50/60 Hz LLC052E Remote Reset Module 00/27 V 50/60 Hz LLC052F 200/240 V 50/60 Hz LLC052M When adding a remote reset module to a LE UI enclosed device (page 6), an oversized enclosure is required. File E6487 CCN NKJH NKJH7 File LR Class / Schneider Electric All Rights Reserved

14 INTEGRAL 8/32/63 Accessories LA9D092 LA4D LA4DE2 O LA4DM LA4DR U LA4DL LA4DT U LA4DWB LA4DF LLB080BD O LD5LB O LA9D092 LDLB LL 080 D LL 80BD LL 580 D RESET LD5LC,LD O LDLC,LD LD4LC,LD 2000 Schneider Electric All Rights Reserved 0/00

15 INTEGRAL 8/32/63 Accessories The top-mounted, add-on voltage converter modules are required to allow operation of an INTEGRAL CMC with DC control voltage. The converters may only be used with the coils shown in the table below. NOTE: When INTEGRAL CMCs are factory ordered with a DC coil code (from Table A / B and Table 2, Page 6), these converter modules need not be ordered separately. Voltage Converter Modules c a Description Nominal Voltage For Use With Coils Catalog Number INTEGRAL 8 Converter Module 24 Vdc LXLB024 LLB080BD 24 Vdc LXLC0249 LLC080BD INTEGRAL 32 Converter Module 48 Vdc LXLC0489 LLC080ED LLC80BD INTEGRAL 63 Converter Module 0 Vdc LXLC09 LLC080FD 24 Vdc LXLD0249 LLD080BD 48 Vdc LXLD0489 LLD080ED 0 Vdc LXLD09 LLD080FD c When using a rectified AC supply, ripple must not exceed %. a Reversing INTEGRAL CMCs require use of two converter modules. The interface modules allow INTEGRAL CMCs to be energized from low voltage and low current signals. Solid state and mechanical relay versions are both available. The relay plus manual override version includes a slide switch for manually energizing the contactor. Interface Modules Description q Type Input Voltage Operational Voltage Catalog Number INTEGRAL 8 Interface Module Solid State Relay 5 to 24 Vdc 24 to 250 Vac LA4DWB File E6487 CCN NKJH NKJH7 Mechanical Relay 24 Vdc 24 to 250 Vac LA4DFB 48 Vdc 24 to 250 Vac LA4DFE 24 Vdc 24 to 250 Vac LA4DLB File LR Class Mechanical Relay plus manual override 48 Vdc 24 to 250 Vac LA4DLE Solid State Relay 5 to 24 Vdc 24 to 240 Vac LLC80BD INTEGRAL 32 Interface Module INTEGRAL 63 Interface Module 24 Vdc 24 to 240 Vac LLC580BD Mechanical Relay 48 Vdc 24 to 240 Vac LLC580ED Solid State Relay 5 to 24 Vdc 24 to 240 Vac LLD80BD 24 Vdc 24 to 240 Vac LLD580BD Mechanical Relay 48 Vdc 24 to 240 Vac LLD580ED q Reversing INTEGRAL CMCs require use of two interface modules. 0/ Schneider Electric All Rights Reserved 5

16 INTEGRAL 8/32/63 Accessories LA9D092 LA4D LA4DE2 O LA4DM LA4DR U LA4DL LA4DT U LA4DWB LA4DF LLB080BD O LD5LB O LDLB LA9D092 LL 080 D LL 80BD LL 580 D RESET LD5LC,LD O LDLC,LD LD4LC,LD Schneider Electric All Rights Reserved 0/00

17 Accessories The control modules allow local or remote operation of the 8 A INTEGRAL CMC. The module includes a slide switch to change from automatic (remote) operation to manual (local) operation. When in manual mode, a separate dial allows the user to locally energize and de-energize the combination motor controller. Automatic - Manual - Stop Control Module (for INTEGRAL 8 only) LA4DMU Description Control Voltage Catalog Number Vac LA4DMK Auto- Manual-Stop Module Vac LA4DMU These electronic timer modules delay the energization or de-energization of the 8 ampere INTEGRAL CMC. Electronic Timer Module (for INTEGRAL 8 only) LA4DROU Description Time Delay Operational Voltage c 50/60 Hz AC Catalog Number 0. to 2 sec. 24 to 240 Vac LA4DT0U On-Delay Timer Module.5 to 30 sec. 24 to 240 Vac LA4DT2U 25 to 500 sec. 24 to 240 Vac LA4DT4U 0. to 2 sec. 24 to 240 Vac LA4DR0U Off-Delay Timer Module.5 to 30 sec. 24 to 240 Vac LA4DR2U 25 to 500 sec. 24 to 240 Vac LA4DR4U c For 24 Vac operation, INTEGRAL CMCs requires a 2 volt coil, see coil table page 9. The coil suppressor modules reduce electrical noise generated by operation of the INTEGRAL CMC. Coil Suppressor Modules LA4DU Description For Use With Operational Voltage 50/60 Hz AC Catalog Number 24 to 48 Vac LA4DE RC Circuit 8A INTEGRAL 50 to 27 Vac LA4DG 0 to 250 Vac LA4DU 24 to 48 Vac LA4DE2E Varistor 8A INTEGRAL 50 to 27 Vac LA4DE2G 0 to 250 Vac LA4DE2E RC Circuit 8A, 32A, 63A INTEGRAL 24 to 250 Vac LA9D092 File E64353 CCN NKJH File LR Class / Schneider Electric All Rights Reserved 7

18 INTEGRAL 8/32/63 Accessories Other Accessories Description Usage Catalog Number Control Knob Padlocking Kit Attaches to front face of INTEGRAL 8 to allow attachment of up to 3 padlocks LA9LB390 Control Circuit Test Device Used on INTEGRAL 8 only LA9LB3 LA9LB930 Mounting Plate To mount I8 or I32 on two 32 mm Omega rails To mount I32 on one 75mm or two 32mm Omega rails LA9LC00 LA9LC02 To mount I63 on one 75mm Omega rail LA9LD00 DIN Rail, 35 mm AMDE200. DIN Rail, 75 mm Connection Accessories (INTEGRAL 8 Units Only) Description AMDL20 Catalog Number Set of 63 A 3-pole busbars to supply an additional INTEGRAL LA9LB930 (2) GVG09 Terminal to supply one or more LA9LB930 busbar sets; cables connected to top GVG09 () Terminal to supply one or more LA9LB930 busbar sets; cables connected to bottom LA9LB960 (2) Through the Door Operators (IP54) Description For Use With Knob Color Catalog Number I8 (LD or LD5) Red Black LA9LB330 LA9LB33 Adjustable Depth Operator t (from 0 to 85mm depth) I32, I63 (LD) Red Black LA9LC330 LA9LC33 I32, I63 (LD4 or LD5) Red Black LA9LC530 LA9LC53 LA9LB960 I8 (LD or LD5) Red Black LA9LB320 LA9LB32 Fixed Depth Operator t I32, I63 (LD) Red Black LA9LC320 LA9LC32 I32, I63 (LD4 or LD5) Red Black LA9LC520 LA9LC52 t See page 49 for mounting dimensions. LA9LC70 Protection Accessories Description For use with Sold in Lots of Catalog Number Finger Protection Cover for power terminals (L, L2, L3) Anti-tamper cover for: protection module LB INTEGRAL 32 5 LA9LC70 INTEGRAL 63 5 LA9LD70 INTEGRAL 8 LLB090 protection module LC or LD INTEGRAL 32 or 63 LLC090 LA9Lk090 For use with trip modules manufactured after January, 9. () (2) File E64864 CCN NLRV File E6487 CCN NKJH NKJH7 File LR 8630 Class File LR Class Schneider Electric All Rights Reserved 0/00

19 INTEGRAL 8/32/63 Accessories AC Coils DC Coils c Nominal Voltage 60 Hz Coil Cat. No. 50 Hz Coil Cat. No. Nominal Voltage Converter Cat. No. DC Coil Cat. No. 8 A Models 8 A model LXLBkkk 2 LXLB09 LXLB02 24 LXLB02 LXLB LXLB LXLB LXLB042 LXLB048 0 LXLB00 LXLB0 5/20 LXLB05 27 LXLB LXLB200 LXLB LLB080BD LXLB A models 24 LLC080BD LXLC LLC080ED LXLC LLC080FD LXLC09 63 A models 24 LLD080BD LXLD LLD080ED LXLD LLD080FD LXLD09 LXLCkkk 230/240 LXLB LXLB240 c INTEGRAL CMCs can operate on D.C. control voltage when fitted with a coil and converter from the table above. 380 LXLB LXLB LXLB380 LXLB /480 LXLB LXLB /600 LX LB LXLB A models LXLDkkk 24 LXLC020 LXLC LXLC0 20 LXLC LXLC90 LXLC LXLC90 LXLC LXLC A models 24 LXLD020 LXLD024 0 LXLD090 LXLD0 20 LXLD LXLD80 LXLD LXLD90 LXLD LXLD380-0/ Schneider Electric All Rights Reserved 9

20 Accessories LA9C6P2 All except Transformers Transformers File E839 CCN NKCR NKCR7 File LR Class File E 6239 CCN XPTQ XPTQ7 Pilot devices and control transformers for enclosed INTEGRAL CMCs can be ordered in one of two convenient ways. Telemecanique INSTA-KITS may be installed at our factory by attaching the form number suffix from the table below to the end of the catalog number selected in Table B on page 6. Alternatively, the INSTA-KIT may be ordered separately by choosing the appropriate catalog number from the right-most column below. INSTA-KITS are easily installed in the field by removing the existing cover plate on the enclosure, installing the INSTA-KIT plate, and plugging the pre-terminated wires into its mating connector. Table 4: INSTA-KITS Selection. f c a q e Description Complete the form number or catalog number with one of the following voltage codes: Voltage D D2 D3 D D33 Primary 480/ / /400/45 Secondary /230 Replace t with the suffix letter corresponding to the pilot light voltage. Factory-Installed Form Numbera On/Off Selector Switch C6 LA9C6 INSTA-KIT Catalog Number Hand-Off-Auto Selector Switch C LA9C Green Pilot Light P2 q LA9P2 q Red Pilot Light P q LA9P2 q Green Transformer Pilot Light P52 q LA9P552* c q Red Transformer Pilot Light P5 q LA9P552* c q Start/Stop Pushbutton A LA9A Start/Stop (Mushroom Head) Pushbuttons 2 LA9 I/O (Start/Stop) Pushbutton A6 On/Off Selector Switch with Green Pilot Light C6P2 LA9C6P2 On/Off Selector Switch with Red Pilot Light C6P LA9C6P2 Hand-Off-Auto Selector Switch with Green Pilot Light CP2 LA9CP2 Hand-Off-Auto Selector Switch with Red Pilot Light CP LA9CP2 H-O-A Selector Switch with Green Transformer Pilot Light CP52 LA9CP552t c H-O-A Selector Switch with Red Transformer Pilot Light CP5 LA9CP552t c Forward-Reverse-Stop Pushbuttons LA9 Start/Stop Pushbutton with Green Pilot Light AP2 LA9AP2 Start/Stop Pushbutton with Red Pilot Light AP LA9AP2 Start/Stop Pushbutton with Green Transformer Pilot Light AP52 LA9AP552t c Start/Stop Pushbutton with Red Transformer Pilot Light AP5 LA9AP552t c Standard Control Transformer with Top Mounted Fuse Block: 50 VA Transformer (Standard size for INTEGRAL 8 and 32) FF4TKF50f LA9FF4TKF50f 00 VA Transformer (Extra capacity for I8 or I32; Std. capacity for I63) FF4TKF00f LA9FF4TKF00f 50 VA Transformer (Extra capacity for INTEGRAL 63) FF4TKF50f LA9FF4TKF50f Local/Remote Adapter - Three Wire q LA93W Local/Remote Adapter - Four Wire q LA94W Local/Remote Adapter - Five Wire q LAW Local/Remote Adapter - Seven Wire q LA97W Fuse Kit for Remote e LA9FK Voltage 24 V 20 V 208/240 V 480 V Suffix Letter B K P W For factory modification, add form number to the end of the catalog number. kla93w required when START/STOP pushbutton remote station is used in conjunction with START/STOP local control OR if local pilot light only is used. kla94w required when FOR/REV/STOP is required for both local and remote control. klaw required when START/STOP pushbutton with pilot light remote station OR pilot light only remote is used with START/STOP pushbutton local control. kla97w required for remote control only applications. Required when local/remote adapters are used Schneider Electric All Rights Reserved 0/00

21 INTEGRAL 8/32/63 Technical Data Mechanical and Electrical Life Curves Based on Utilization Category and Number of Switching Cycles Alternating Current Utilization Category AC-3 Operating voltage 200 V 230 V 460 V 575 V Operating current at q 04 F (40 C) INTEGRAL 8 8 A 8 A 8 A 8 A INTEGRAL A 32 A 32 A 32 A INTEGRAL A 63 A 63 A 63 A Rated horsepower at q 04 F (40 C) INTEGRAL 8 5 hp 5 hp 0 hp 5 hp INTEGRAL 32 0 hp 0 hp 20 hp 30 hp INTEGRAL hp 20 hp 40 hp 60 hp Electrical life Motor control and protection in utilization categories AC-2, AC-3, AC-4, at Ue 400 volts Current Breaking Limit INTEGRAL 8 INTEGRAL 32 and 63 Millions of operating cycles Millions of operating cycles (32A) 4 (63A) Current broken in amperes Not having previously broken a short circuit current ➁ Having broken a short circuit current 0 times at 30 In a ➂ Having broken a short circuit current 20 times at 30 In a ➃ Having broken a short circuit current 0 times at 00 In a Most common value of short circuit current Current broken in amperes 0/ Schneider Electric All Rights Reserved 2

22 INTEGRAL 8/32/63 Technical Data Mechanical and Electrical Life Curves Based on Utilization Category and Number of Switching Cycles Electrical life curves CMC size Wire size (AWG) Maximum rate of operating cycles per hour Operating duty 85% - operation at maximum current - operation at 50% of maximum current Operating duty 25% - operation at maximum current Operating current (according to ambient temperature) q 04 F (40 C) 8 A 32 A 63 A q F (55 C) 6 A 28 A 55 A q 58 F (70 C) A 25 A 50 A Electrical Life Utilization category AC-, Ue 400 Volts Millions of operating cycles (8 A) (32 A) (63 A) Current broken in amperes Schneider Electric All Rights Reserved 0/00

23 PROTECTON MODULE TRIPPING SPECIFICATIONS Motor Protection By thermal magnetic modules LBLB03P INTEGRAL Self-Protected Combination Motor Controllers INTEGRAL 8 Technical Data 300 mn 00 mn 0 mn P0 P03 P02 P04 P05 P06 P07 P08 P0 P P7 P2 mn 0s The average operating times shown are for ambient temperature of 68 F (20 C), without prior current flow (cold state). The average operating time after prolonged current flow (hot state) can be calculated by applying a coefficient of 0.5. s 0.s s Current in amperes CURRENT LIMITATION AND THERMAL LIMIT ON SHORT CIRCUIT 3-Phase 380/45 V, 50 Hz Current limit on short circuit Max. I peak in KA Thermal limit I 2 t in ka 2 s in short circuit protection zone cos ϕ =0.7 =0.5 =0.3 = A 6-0 A 4-6 A A A -.6 A 0-6 A A Prospective Isc in ka rms A 0-6 A 6-0 A 4-6 A A A -.6 A Prospective Isc in ka rms 0/ Schneider Electric All Rights Reserved 23

24 INTEGRAL 32 Technical Data Motor Protection By thermal magnetic modules LBLC03M Motor Protection (frequent starting) By magnetic modules LB6LC03M 300 min 00 min 0 min min 0 s irth M03 M04 M05 M06 M07 M08 M0 M M7 M22 M min 00 min 0 min min 0 s M06 M08 M M22 s s M07 M0 M7 M s s s 0.0 s The average operating times shown are for ambient temperature of 68 F (20 C), without prior current flow (cold state). The average operating time after prolonged current flow (hot state) can be calculated by applying a coefficient of 0.5. Tripping Curve on Short Circuit Breaking time in ms V Prospective Isc in ka rms Schneider Electric All Rights Reserved 0/00

25 CURRENT LIMITATION AND THERMAL LIMIT ON SHORT-CIRCUIT 3-Phase 400/45 V, 50 Hz INTEGRAL Self-Protected Combination Motor Controllers INTEGRAL 32 Technical Data Current limitation on short-circuit Max. I peak in KA Maximum thermal limit on short-circuit Thermal limit I 2 t in ka 2 s in short circuit protection zone cosϕ=0.7 =0.5 =0.3 = a a Prospective rms short-circuit current in ka Prospective rms short-circuit current in ka 3-Phase 400/45 V, 50 Hz Current limitation on short-circuit Max. I peak in KA Maximum thermal limit on short-circuit Thermal limit I 2 t in ka 2 s in short circuit protection zone cosϕ=0.7 =0.5 = a a Prospective rms short-circuit current in ka Prospective rms short-circuit current in ka a Associated thermal protection rating. For -.6 A ratings, the thermal limit is less than x0 3 A 2 s -.6 A A The breaking capacity is unlimited on contactor breakers fitted A A with modules: - up to a rating of 0-6 A at 220/380/45 V A A - up to a rating of A at 440/500 V A A 0/ Schneider Electric All Rights Reserved 25

26 INTEGRAL 63 Technical Data PROTECTION MODULE TRIPPING SPECIFICATIONS Motor Protection (normal starting duty) By thermal magnetic modules LBLD03M 300 mn 00 mn 0 mn irth M6 M2 M22 M53 M55 M57 M6 mn 0 s s s 0.0s Current in amperes The average operating times shown are for ambient temperature of 68 F (20 C), without prior current flow (cold state). The average operating time after prolonged current flow (hot state) can be calculated by applying a coefficient of 0.5. Tripping Curve on Short Circuit Breaking time in ms V Prospective short-circuit current in ka rms Schneider Electric All Rights Reserved 0/00

27 CURRENT LIMITATION AND THERMAL LIMIT ON SHORT-CIRCUIT 3-Phase 400/45 V, 50 Hz INTEGRAL Self-Protected Combination Motor Controllers INTEGRAL 63 Technical Data Current limitation on short-circuit Maximum peak current in ka Maximum thermal limit on short-circuit Thermal limit I 2 t in ka 2 s in short circuit protection zone = cos ϕ = 0.7 = 0.5 = 0.3 a a Prospective rms short-circuit current in ka Prospective rms short-circuit current in ka 3-Phase 400/45 V, 50 Hz Current limitation on short-circuit Maximum peak current in ka Maximum thermal limit on short-circuit Thermal limit I 2 t in ka 2 s in short circuit protection zone = = cos ϕ = 0.7 = 0.5 a a Prospective rms short-circuit current in ka Prospective rms short-circuit current in ka 8-25 A up to 45-63A a LBLD03 22 to LD03 6: rating of associated thermal overload module. 0/ Schneider Electric All Rights Reserved 27

28 Specifications Specifications Type INTEGRAL 8 Rated operational current (Ie) Category AC-3 8 A Rated operational voltage (Ue) 600 Vac Breaking capacity at 480 Vac 42 ka RMS Electrical durability in AC-3 at 400 V 2 million operating cycles Mechanical durability at Uc 0 million operating cycles Maximum operating rate AC control voltage 200 operating cycles/hour at ambient temperature F (55 C) DC control voltage with converter 600 operating cycles/hour Environment Conforming to standards IEC: 364, 947-, 947-2, , UTE: NF C 63-0, C 63-20, C 63-0, C , C 79-00, C VDE: 000, 00, 0, 070, 07, 47, 0660 EN , , , NEN, NBN Product approvals UL File Number ASE, ASEFA, ASTA, CSA, DEMKO, DNV NEMKO, RINA, SEMKO, SETI, UL File E6487, CCN NKJH CSA File Number File LR43364 Class Protective treatment Ambient air temperature around the device Vibration resistance Permissible acceleration Shock resistance Permissible acceleration TH Operation - to + F (-25 to +55 C) Storage -40 to +76 F (-40 to +80 C) Operation - to +22 F (-25 to +50 C) Storage - to +58 F (-25 to +70 C) 5 to 00 Hz Energized state: 3 g De-energized state: 3 g Impulse duration: ms Degree of protection To IEC 4 and 529 To VDE 006 Energized state: 8 g De-energized state: 8 g IP 20B Protection against direct finger contact Flame resistance Conforming to IEC 2-2-, NF C , and to decree of (JO 27 NC of st and 2/2/2) Conforming to UL 94 - V0 and NF T Maximum operating altitude Without derating 9,580/3000 ft/m Operating position (without derating) In relation to normal vertical mounting plane From fixing plane (fore-aft tilt) From main axis (left-right tilt) Control Circuit Specifications Rated control circuit voltage (Uc) Voltage limits at θ F (55 C) Average consumption at 68 F (20 C) and at Uc Heat dissipation Operating time at 68 F (20 C) and at Uc 50 Hz 60 Hz DC with converter Operating Drop out AC Inrush Sealed DC Inrush Sealed 50/60 Hz C O DC with converter C O 2 to 660 Vac 2 to 600 Vac 24 Vdc 0.85 to. Uc 0.25 to 0.7 Uc 75 VA (50 Hz), 90 VA (60 Hz) 8 VA (50 Hz), 9 VA(60 Hz) 00 W.5 W 2.5 W (50 Hz), 2.8 W (60 Hz) 9 to 25 ms 7 to 25 ms 5 to 20 ms 20 to 25 ms With converter. The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measure from the moment the coil supply is switched off to the moment the main poles separate Schneider Electric All Rights Reserved 0/00

29 Specifications Specifications INTEGRAL 32 INTEGRAL A 63 A 600 Vac 600 Vac 42 ka RMS 42 ka RMS.5 million operating cycles.2 million operating cycles 0 million operating cycles 0 million operating cycles 3600 operating cycles/hour 3600 operating cycles/hour 600 operating cycles/hour 600 operating cycles/hour Environment IEC: 364, 947-, 947-2, , UTE: NF C 63-0, C 63-20, C 63-0, C , C 79-00, C VDE: 000, 00, 0, 070, 07, 47, 0660 EN , , , NEN, NBN ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, PTB, RINA, SCC, SETI, UL, USSR, LROS File E6487, CCN NKJH File E6487, CCN NKJH File LR43364 Class File LR43364 Class TH TH - to +58 F (-25 to +70 C) - to +58 F (-25 to +70 C) -40 to +76 F (-40 to +80 C) -40 to +76 F (-40 to +80 C) - to +22 F (-25 to +50 C) - to +22 F (-25 to +50 C) - to +58 F (-25 to +70 C) - to +58 F (-25 to +70 C) Energized state: 3 g De-energized state: 3 g Energized state: 8 g De-energized state: 8 g IP 20B Protection against direct finger contact Conforming to IEC 2-2-, NF C , and to decree of (JO 27 NC of st and 2/2/2) Conforming to UL 94 - V0 and NF T IEC: 364, 947-, 947-2, , UTE: NF C 63-0, C 63-20, C 63-0, C , C 79-00, C VDE: 000, 00, 0, 070, 07, 47, 0660 EN , , , NEN, NBN ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, RINA, SCC, SETI, UL, USSR, LROS pending Energized state: 3 g De-energized state: 3 g Energized state: 8 g De-energized state: 8 g 9,580/3000 ft/m 9,580/3000 ft/m From fixing plane (fore-aft tilt) IP 20B Protection against direct finger contact Conforming to IEC 2-2-, NF C , and to decree of (JO 27 NC of st and 2/2/2) Conforming to UL 94 - V0 and NF T From fixing plane (fore-aft tilt) Control Circuit Specifications 24 to 660 Vac 24 to 600 Vac 24, 48, 0 Vdc 0.85 to. Uc 0.25 to 0.7 Uc 60 VA (50 Hz), 85 VA (60 Hz) 2 VA (50 or 60 Hz) 250 W, duration 50 ms 4 W 24 to 660 Vac 24 to 600 Vac 24, 48, 0 Vdc 0.85 to. Uc 0.25 to 0.7 Uc 375 VA (50 Hz), 450 VA (60 Hz) 25 VA (50 or 60 Hz) 300 W, duration 50 ms 8 W 4 W (50 Hz), 5 W (60 Hz) 8 W (50 Hz), W (60 Hz) 9 to 25 ms 7 to 20 ms 25 to 35 ms 0 to 20 ms 2 to 35 ms 7 to 20 ms 25 to 40 ms 5 to 25 ms 0/ Schneider Electric All Rights Reserved 29

30 Specifications Specifications Type INTEGRAL 8 Pole Specifications Rated thermal current (Ith) θ 04 F (40 C) 8 A Frequency limits of operational current Hz Rated impulse withstand voltage To IEC kv in envelope Rated insulation voltage (Ui) To IEC 947- and NF C Vac Heat dissipation in the power circuits of the contactor breaker Operational current 0.6 A 0.25 A 0.4 A 0.6 A.0 A.6 A 2.5 A 4.0 A 6.0 A 0.0 A 6.0 A 8.0 A and its protection module Power per pole, hot state 2.3 W 2.3 W 2.3 W 2.3 W 2.3 W 2.3 W 2.3 W 2.4 W 2.9 W 3.2 W 3.8 W 3.8 W Rated making capacity I RMS To IEC and NF C x Ith (above this value, the breaker trips Total breaking time Electrical durability in AC-3 at Ie max, Ue = 45 V after P2 cycle (O-t-CO-t-CO) (short-circuit test) I Peak To IEC and NF C ka Prospective RMS short-circuit current at terminals of a new device 2.5 ms 3 ka 0 ka 25 ka 35 ka 42 ka Millions of operating cycles Maximum let-through energy With Isc max, at 45 V, 50 Hz 00 x 0 3 A 2 s Wiring Tightening torque Specifications of Thermal-magnetic or Magnetic Only Protection Modules Type Protection Maximum cross-sectional area (c.s.a.) Minimum cross-sectional area (c.s.a.) Flexible cable without cable end 2 x 6 mm 2 2 x.5 mm #6 to 2 - #0 Flexible cable with cable end 2 x 4 mm 2 or x 6 mm 2 2 x mm #6 to 2 - #0 Solid cable 2 x 6 mm 2 2 x.5 mm #6 to 2 - #0 2 lb-in (.7 N m) LBLB03P Standard motors Conforming to standards IEC type 2 (Iq = 80 ka except P2) and NF C Number of poles 3 Number of protection poles 3 Rated operational voltage 600 Vac Maximum continuous current 0.6 to 8 A Thermal protection Setting range (Irth min/irth max) 0./0.6 to 2/8 A Temperature compensation -4 to + F (-20 to +55 C) Protection against phase imbalance With Tripping class 0 Magnetic protection Instantaneous trip current setting range Fixed at 5 Irth max To IEC 58- and NF C IEC 947-/2/4 and NF C Tripping tolerance ± 20% Specifications of Versions without Isolator Function Conforming to standards IEC 947 Rated operational voltage 600 Vac Mechanical durability 0,000 operating cycle Padlocking facility padlock, 5 mm shank Specifications of Versions with Isolator Function Conforming to standards Rated operational voltage Mechanical durability Padlocking facility AWG Schneider Electric All Rights Reserved 0/00

31 Specifications Specifications INTEGRAL 32 INTEGRAL 63 Pole Specifications 32 A 63 A Hz Hz 6 kv in envelope 6 kv in envelope 600 Vac 600 Vac.6 A 2.5 A 4.0 A 6.3 A 0.0 A 6.0 A 25.0 A 32.0 A 25 A 32 A 40 A 50 A 63 A.6 W.8 W.8 W 2.0 W 2.0 W 3.4 W 4.8 W 6.0 W 4.4 W 5.0 W 5.8 W 7.0 W 9.0 W 2 x Ith (above this value, the breaker trips 2 or 5 x Ith (above this value, the breaker trips 05 ka 05 ka 4 ms 4 ms 3 ka 0 ka 25 ka 35 ka 42 ka 3 ka 0 ka 25 ka 35 ka 42 ka x 0 3 A 2 s 300 x 0 3 A 2 s Maximum cross-sectional area (c.s.a.) Minimum cross-sectional area (c.s.a.) AWG Maximum cross-sectional area (c.s.a.) Minimum cross-sectional area (c.s.a.) X 0 or 2 x 6 mm 2 x mm 2 #8 to #8 X 50 or 2 x 35 mm 2 x 6 mm 2 #0 to #2 x 6 or 2 x 4 mm 2 x mm 2 #8 to #8 2 x 25 mm 2 x 6 mm 2 #0 to #2 x 0 or 2 x 6 mm 2 x mm 2 #8 to #8 x 50 mm 2 x 6 mm 2 #0 to #2 lb-in (2.0 N m) 42 lb-in (6.0 N m) Specifications of Thermal-magnetic or Magnetic Only Protection Modules LBLC03M LB6LC03M LBLD03M LB6LD03M Standard motors Frequent starting motors Standard motors Frequent starting motors IEC type 2 (Iq = 50 ka) and NF C NF C NF C NF C Vac 600 Vac 600 Vac 600 Vac 0.4 to 32 A 0.4 to 32 A to 63 to /0.4 to 23/32 A 0/ to 45/63 A -4 to +58 F (-20 to +70 C) -4 to +58 F (-20 to +70 C) -4 to +58 F (-20 to +70 C) -4 to +58 F (-20 to +70 C) With Without With Without to 2 Irth max (Usual setting 9 to 0 Irth max) 6 to 2 Irth max 6 to 2 Irth max (Usual setting 9 to 0 Irth max) 6 to 2 Irth max ± 20% ± 20% ± 20% ± 20% Specifications of Versions without Isolator Function IEC 947 IEC Vac 600 Vac 0,000 operating cycles 0,000 operating cycle, 2, or 3 padlocks, 8 mm shank, 2, or 3 padlocks, 8 mm shank Specifications of Versions with Isolator Function IEC 947, NF C 63-0, VDE 0660, VDE 0 IEC 947, NF C 63-0, VDE 0660, VDE Vac 600 Vac 0,000 operating cycles 0,000 operating cycles, 2, or 3 padlocks (shank 8 mm max and 5 mm min). When flush mounting, interlocking of the enclosure or cabinet door is possible. AWG, 2, or 3 padlocks (shank 8 mm max and 5 mm min). When flush mounting, interlocking of the enclosure or cabinet door is possible. 0/ Schneider Electric All Rights Reserved 3

32 Specifications Instantaneous Auxiliary Contacts Rated thermal current (Ith) 0 A (INTEGRAL 8), 6 A (INTEGRAL 32 and 63) Rated insulation voltage (Ui) To IEC 947- and NF C Vac Switching capacity With U 7 V and I 0 ma 600 mva AC category AC-5 c Voltage 48 Vac 0/20 Vac 220/240 Vac 380/400 Vac 480 Vac Rated operational power million operating cycles 300 VA 500 VA 600 VA 520 VA 500 VA.5 million operating cycles 60 VA 300 VA 330 VA 300 VA 280 VA Making capacity AC category AC VA 3500 VA 6000 VA 7500 VA 7000 VA DC category DC- q Voltage 24 Vac 48 Vac 0 Vac 220 Vac 440 Vac Rated operational power million operating cycles 20 W 90 W 75 W 68 W 6 W.5 million operating cycles 70 W 50 W 38 W 33 W 28 W Making capacity DC category DC- 800 W 700 W 400 W 260 W 220 W Maximum c.s.a.: 2 x 2.5 mm 2. Minimum c.s.a.: 2 x mm 2 Wire size Maximum: 2 x AWG, Minimum: 2 x 6 AWG c Electrical durability on an inductive load such as the coil of an electromagnet: making capacity (cosϕ 0.7) = 0 times the breaking capacity (cos ϕ 0.4). q Electrical durability on an inductive load such as the coil of an electromagnet, the time constant increasing with the power. Signalling Contacts Rated thermal current (Ith) 6 A (INTEGRAL 8), 3 A (INTEGRAL 32 and 63) Rated insulation voltage (Ui) To IEC Vac (INTEGRAL 8), 250 Vac (INTEGRAL 32 and 63) Operational power AC Voltage 0/27 Vac 220 Vac for operating cycles Resistive load 600 VA 750 VA Lamp load k 90 VA 25 VA Inductive load f 875 VA 500 VA Motor p 60 VA 200 VA DC Voltage 24 Vac 48 Vac 0/25 Vac 200 Vac Resistive load 00 W 00 W 50 W 50 W Lamp load k 50 W 50 W 6 W 7.5 W Inductive load f 75 W 75 W 50 W 50 W Motor p 75 W 75 W 6 W 7.5 W Maximum c.s.a.: 2 x 2.5 mm 2. Minimum c.s.a.: 2 x mm 2 Wire size Maximum: 2 x AWG, Minimum: 2 x 6 AWG k Lamp load: peak current = 0 times the rated current. f Inductive load: cos ϕ 0.4 for AC operation; time constant 7 ms for DC operation. p Motor: peak current = 6 times the rated current. Isolating Auxiliary Contacts for INTEGRAL 32 and 63 Rated thermal current (Ith) 6 A Rated insulation voltage (Ui) to IEC 947 and NF C 63-0 Wire size AC supply DC supply 690 Vac 25 Vac Maximum c.s.a.: 2 x.5 or x 2.5 mm 2 Maximum: 2 x 6 AWG or x AWG Schneider Electric All Rights Reserved 0/00

33 Specifications Environment Type LA4DT (On-delay) LA4DR (Off-delay) Conforming to standards IEC IEC Product approvals Pending UL, CSA UL, CSA Protective treatment TH TH Degree of protection To VDE 006 Against direct finger contact Against direct finger contact Ambient air temperature around the device Rated insulation voltage (Ui) Time Delay Specifications Storage -40 to +76 F (-40 to +80 C) -40 to +76 F (-40 to +80 C) Operation - to + F (-25 to +55 C) - to + F (-25 to +55 C) Operation at Uc - to +58 F (-25 to +70 C) - to +58 F (-25 to +70 C) To IEC 947- and VDE 00 (group C) 250 Vac 250 Vac Timing ranges 0.-2/.5-0/ sec. 0.-2/.5-30/ sec. Repeat accuracy F (0-40 C) ± 3% (0 ms minimum) ± 3% (0 ms minimum) During the time delay 00 ms 225 ms Reset time After the time delay 50 ms During the time delay 0 ms 20 ms Immunity to micro-breaks After the time delay 2 ms Minimum control pulse duration 40 ms Time delay signalling By LED Illuminates during time delay Illuminates during time delay Control Circuit Specifications On input By varistor By varistor Built-in protection Contactor breaker coil suppression By varistor By peak limiting diode Rated control circuit voltage (Uc) Vac or Vdc Vac Voltage limits Uc Uc Control type Wire Size Switching Specifications (solid state type) Flexible or solid cable with or without cable end By mechanical contact only By mechanical contact only (connecting cable < 0 m) Minimum c.s.a.: x mm 2 Minimum c.s.a.: x mm 2 Maximum c.s.a.: 2 x 2.5 mm 2 Maximum c.s.a.: 2 x 2.5 mm 2 Minimum: x 6 AWG Maximum: 2 x AWG Maximum power dissipated 2 W 3.5 W Leakage current < 5 ma < 5 ma Residual voltage 3.3 Vac 3.3 V Minimum: x 6 AWG Maximum: 2 x AWG Overvoltage protection 3 kv; 0.5 joule 3 kv; 0.5 joule Electrical durability 30 million operating cycles 30 million operating cycles Operating diagrams Electronic on-delay timer LA4DT Electronic off-delay timer LA4DR Uc supply ( - ) 0 Uc supply ( - ) Control ( - B2) ms Time delay output Contactor breaker coil 0 t Time delay output Contactor breaker coil 0 t Red LED Red LED 0/ Schneider Electric All Rights Reserved 33

34 Specifications Type Interface modules Converters Used for direct control of the INTEGRAL 8 By a programmable controller, with AC control of the coil Protective treatment TH TH By a programmable controller, with DC control of the coil. Ambient air temperature Storage: -04 to + 76 F (- 40 to+ 80 C) Storage: -04 to + 76 F (- 40 to + 80 C) around the device Operation: - to + F (-25 to +55 C) Operation: - to +22 F (-25 to +50 C) Rated insulation voltage (Ui) 250 Vac to IEC 58- and 947- and VDE 00 (group C) Protection against direct finger contact Conforming to VDE 006 Conforming to VDE 006 Max: 2 x 2.5 mm 2, Min: x mm 2 Max: 2 x 2.5 mm 2, Min: x mm 2 Cabling Max: 2 x AWG, Min: x 6 AWG Max: 2 x AWG, Min: x 6 AWG Operating limits 0.8 to. Uc q Protection Of the input and against reverse polarity: by diode Against reverse polarity (by diode) and against overvoltage Control Circuit Specifications Type LA4DFB LA4DFE LA4DLB LA4DLE LA4DWB LLB080BD Technology Relay Relay + override Solid state Solid state Wiring Schematics c E + E2 c c E + E2 c c E + E2 c + (0V) E E3 E2 K K K Indication of input state Input signals (logic side) Voltage (E-E2) By built-in LED 24 Vdc 48 Vdc 24 Vdc 48 Vdc 5-24 Vdc 24 Vdc (E2-E3) Current 25 ma 5 ma 25 ma 5 ma 8.5 for 5 V 5 for 24 V State 0 guaranteed for U < 2.4 Vac < 4.8 Vac < 2.4 Vac < 4.8 Vac < 2.4 Vac < 7 Vac or I < 2 Vac <.3 Vac < 2 Vac <.3 Vac < 2 Vac < 5 Vac State guaranteed for U 7 < U < 30 Vac 33 < U < 60 Vac 7 < U < 30 Vac 33 < U < 60 Vac 5 < U < 30 U > Supply voltage Vac (-) 24 Vdc (E-E2) q Operating Specifications Electrical durability in Immunity to control circuit interruptions Average consumption at 86 F (30 C) Operating time c at 86 F (30 C) and at Uc 0 million operating cycles 0 million operating cycles 3 million operating cycles 3 million operating cycles 20 million operating cycles 4 ms 4 ms 4 ms 4 ms ms 0.6 W 0.6 W 0.6 W 0.6 W 0.4 W c The operating times depend on the type of electromagnet driving the contactor breaker and its control method. The closing time C is measured from the moment the INTEGRAL coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the main poles separate. q Warning: for supply from rectified AC, the power supply must exceed 50 VA and the maximum ripple must be %. 0 2 million operating cycles Inrush: 00 Sealed:.5 Pull-in 5-30 ms 5-30 ms 5-30 ms 5-30 ms 30 ms Drop-out ms ms ms ms 5 ms Schneider Electric All Rights Reserved 0/00

35 Specifications Type Interface modules Converters Used for direct control of the INTEGRAL 32 or 63 By a programmable controller, with AC control of the electromagnet By a programmable controller, with DC control of the coil Ambient air temperature around the device Storage: - to +58 F (- 25 to + 70 C) Operation: - to +22 F (- 25 to+ 50 C) Storage: - to +58 F (- 25 to + 70 C) Operation: - to +22 F (- 25 to + 50 C) Insulation rms voltage between inputs and outputs: 2.5 kv Common negative terminals Wiring Max: 2 x 2.5 mm 2, Min: x mm 2 Max: 2 x 2.5 mm 2, Min: x mm 2 Max: 2 x AWG, Min: x 6 AWG Operating limits Uc Uc q Max: 2 x AWG, Min: x 6 AWG Protection Against reverse polarity (by diode) and against overvoltage Against reverse polarity (by diode) and against overvoltage Indication of input state By LED Type INTEGRAL 32 INTEGRAL 63 INTEGRAL 32 INTEGRAL 63 LLC LLD LLC LLD 580BD 580ED 80BD 580BD 580ED 80BD 080BD 080ED 080FD 080BD 080ED 080FD LL 580 D LL 80BD LL 080BD LL 080FD LL 080ED Wiring Schematics c + E E2 c c + E E2 c + (0V) E E3 E2 + (0V) E E2 Input signals (logic side) Supply voltage 24 Vdc 48 Vdc 5-24 Vdc 24 Vdc 48 Vdc 5-24 Vdc 24 Vdc c 48 Vdc c 24 Vdc c 48 Vdc (E-E2) (E-E2) (E- E2) (E-E2) (E-E2) (E-E2) (E3-E2) (E3-E2) (E3-E2) (E3-E2) 30 ma 20 ma 8.5 at 5V 5 at 24V 50 ma 25 ma 8.5 at 5V 5 at 24V 20 ma 0 ma 20 ma 0 ma State 0 guaranteed for U < 2.4 Vac < 4.8 Vac < 2.5 Vac < 2.4 Vac < 4.8 Vac < 2.5 Vac < 7 Vac < Vac < 7 Vac < Vac I < 2 ma < 2 ma < 2 ma < 2 ma < 2 ma < 2 ma < 5 ma < 2.5 ma < 5 ma < 2.5 ma State guaranteed for U > 20.4 Vac > 40.8 Vac > 4 Vac > 20.4 Vac > 40.8 Vac > 4 Vac > Vac > 28 Vac > Vac > 28 Vac Electrical durability in millions of operating cycles Average consumption Operating time at 68 F (20 C) and at Uc Vac Vac Vac Vac Vac Vac 24 Vdc q 48 Vdc q 0 Vdc q 24 Vdc q 48 Vdc q 0 Vdc q (-) (-) (-) (-) (-) (-) (E-E2) (E-E2) (E-E2) (E-E2) (E-E2) (E-E2) 5 Inrush 50 Hz 60 VA 60 VA 60 VA 375 VA 375 VA 375 VA 60 Hz 85 VA 85 VA 85 VA 450 VA 450 VA 450 VA DC 250 W 250 W 250 W 300 W 300 W 300 W Sealed 50/60 Hz 2 VA 2 VA 2 VA 25 VA 25 VA 25 VA DC 4 W 4 W 4 W 8 W 8 W 8 W Pull-in 5-30 ms 5-30 ms 0-35 ms ms ms 0-45 ms 30 ms 30 ms 30 ms 35 ms 35 ms 35 ms Drop-out ms ms 8-30 ms ms ms 8-30 ms 5 ms 5 ms 5 ms 20 ms 20 ms 20 ms c For direct control by external contact: connect E-E3. q Warning: for supply from rectified a.c., the power supply must exceed 250 VA (300 VA for INTEGRAL 63) and the maximum ripple must be %. 0/ Schneider Electric All Rights Reserved 35

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

AS-i Metal Enclosed DOL Starters

AS-i Metal Enclosed DOL Starters Class 8340 CONTENTS Schneider Electric Brands Description Page Product Configuration and Introduction................................. 2 7 Selection........................................................

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Reduced Voltage Motor Starters

Reduced Voltage Motor Starters Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type

More information

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

CA Z-EN Overload relays, CT-operated overload relays

CA Z-EN   Overload relays, CT-operated overload relays Overload relays, CT-operated overload relays Electronic overload relays, thermistor overload relay for machine protection Setting ranges (A) (note max. current of the contactor) 0.1-12 0.1-16 0.1-38 6-75

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information