NEX - 24 kv Withdrawable Circuit Breaker
|
|
- Stanley Curtis
- 5 years ago
- Views:
Transcription
1 Air Insulated Medium Voltage Equipment NEX - 24 kv Withdrawable Circuit Breaker Installation drawings file
2
3 Contents bj Fitting the upper main busbars 1250 A busbar mm cubicle Assembly 1250 A busbar system of intermediate cubicle F0 (001/006) Assembly 1250 A busbar system of intermediate-lh END cubicle F0 (003/006) Assembly 1250 A busbar system of BOTH SIDE END cubicles F0 (006/006) 2000 A busbar mm cubicle Assembly 2000 A busbar system of intermediate cubicle F0 (002/006) Assembly 2000 A busbar system of intermediate-rh END cubicle F0 (004/006) Assembly 2000 A busbar system of intermediate-lh END cubicle F0 (005/006) 2000 A busbar mm cubicle Busbar assembly 2000A mm cubicle F0 (001/004) Assembly 2000 A busbar system of INTERMEDIATE-RH END cubicle F0 (002/004) Assembly 2000 Abusbar system of INTERMEDIATE-LH END cubicle F0 (003/004) Assembly 2000 A busbar system of BOTH SIDE END cubicles F0 (004/004) bj Fitting the lower busbars 1250 A busbar Lower busbar for coupler-riser A mm wide F0 (001/001) 2000 A busbar Lower busbar for coupler-riser A - Riser on the left side F0 (001/002) Lower busbar for coupler-riser A - Riser on the right side F0 (002/002) bj Installing the bus chamber deflector plates Busbar compartment IF, BC, RF, BM F0 (001/004) Busbar compartment lower BC-RF, RW F0 (002/004) Busbar compartment w/o dividerplate LHS F0 (003/004) Busbar compartment w/o dividerplate RHS F0 (004/004) bj Fitting the busbar joint covers Busbar shroud - 2x80x10 Busb 2x80x10 Conn - RH end opened F0 (001/001) Busbar shroud - 2x80x10 Busb 2x80x10 Conn - LH end opened F0 (001/001) Busbar shroud - 2x80x10 Busb 2x80x10 Conn - Both ends opened F0 (001/001) Busbar shroud - 2x80x10 Busb 2x60x10 Conn - RH end opened F0 (001/001) Busbar shroud - 2x80x10 Busb 2x60x10 Conn - LH end opened F0 (001/001) Busbar shroud - 2x80x10 Busb 2x60x10 Conn - Both ends opened F0 (001/001) Busbar shroud - 1x80x10 Busb 2x60x10 Conn - One side opened F0 (001/001) Busbar shroud - 1x80x10 Busb 2x60x10 Conn - Both ends opened F0 (001/001) bj Installing the end covers Assembly end cover left hand side F0 (001/002) Assembly end cover left hand side F0 (002/002) Assembly end cover right hand side F0 (001/002) Assembly end cover right hand side F0 (002/002) End cover assembly NEX 24 switchboards F0 (001/001) Schneider Electric F0EN - REV. F0-1
4 F0EN - REV. F0 Schneider Electric
5 Schneider Electric F0EN - REV. F0-3
6 F0EN - REV. F0 Schneider Electric
7 Notes Schneider Electric F0EN - REV. F0-5
8 F0EN - REV. F0 Schneider Electric
9 Schneider Electric F0EN - REV. F0-7
10 F0EN - REV. F0 Schneider Electric
11 Notes Schneider Electric F0EN - REV. F0-9
12 F0EN - REV. F0 Schneider Electric
13 Schneider Electric F0EN - REV. F0-11
14 F0EN - REV. F0 Schneider Electric
15 Schneider Electric F0EN - REV. F0-13
16 F0EN - REV. F0 Schneider Electric
17 Notes Schneider Electric F0EN - REV. F0-15
18 F0EN - REV. F0 Schneider Electric
19 Schneider Electric F0EN - REV. F0-17
20 F0EN - REV. F0 Schneider Electric
21 Schneider Electric F0EN - REV. F0-19
22 F0EN - REV. F0 Schneider Electric
23 Schneider Electric F0EN - REV. F0-21
24 F0EN - REV. F0 Schneider Electric
25 Schneider Electric F0EN - REV. F0-23
26 F0EN - REV. F0 Schneider Electric
27 Notes Schneider Electric F0EN - REV. F0-25
28 F0EN - REV. F0 Schneider Electric
29 Schneider Electric F0EN - REV. F0-27
30 F0EN - REV. F0 Schneider Electric
31 Notes Schneider Electric F0EN - REV. F0-29
32 F0EN - REV. F0 Schneider Electric
33 Schneider Electric F0EN - REV. F0-31
34 F0EN - REV. F0 Schneider Electric
35 Schneider Electric F0EN - REV. F0-33
36 F0EN - REV. F0 Schneider Electric
37 Schneider Electric F0EN - REV. F0-35
38 F0EN - REV. F0 Schneider Electric
39 Schneider Electric group service centers are there to provide: - engineering and technical assistance, - commissioning, - training, - preventive and corrective maintenance, - adaptation work, - spare parts. Call your sales representative who will put you in touch with your nearest Schneider Electric group service center or directly call the following telephone number: +33 (0) Grenoble France F0EN - REV. F0 a Schneider Electric Industries SAS All rights reserved. Schneider Electric Industries SAS 89, boulevard Franklin Roosevelt F Rueil-Malmaison Cedex Tel: +33 (0) As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper. Publishing: Schneider Electric Industries SAS. Design: Profil. Printing: F0EN - REV. F0 03/2008
Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient
Medium voltage NEX switchgear Withdrawable circuit breaker Quite simply efficient NEX, a simple and flexible solution NEX is the result of worldwide acquired experience and provides you with a high level
More informationMCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution
Medium Voltage Distribution MCset 17.5 kv ir insulated switchboard Withdrawable switchgear SF6 or vaccum technology Civil engineering guide pril 2012 Contents General 2 Glossary 2 Dimensions and weights
More informationEvolis offer Merlin Gerin
Medium voltage distribution Evolis offer Merlin Gerin Installation guide 200757a General contents Evolis circuit breaker full version 3 Circuit breaker installation 3 Cradle installation and earthing 3
More informationInformation for the modified document
Information for the modified document émetteur : Esref OZYUZUCULER date :03-05 - 2001 Recipient SM6 --- 36kV STT KG K ToK FaZ OrY MRK(TR) E&S S OyR MeM er Number : 7897176EN Index : D0 Product : SM6-36
More informationMCset 4-24 kv Withdrawable SF6 circuit breaker
Medium Voltage switchgear MCset 4-24 kv Withdrawable SF6 circuit breaker Instruction for use Contents General 2 Glossary 2 Symbols 2 Recommendations 3 General description 4 AD4 unit 4 AD4 unit with toroidal
More informationMCset kv Medium voltage equipment
Maintenance Guide PE90014 PE90006 MCset 1-2 - 3 17.5 kv Medium voltage equipment Air-insulated switchboards Metal-enclosed switchgear with moving parts PE90007 PE90008 PE90009 PE90007 Maintenance Guide
More informationI B D Q I B D Q O I B D Q O
Extension offer: new possible combinations 2 and 3 functions RM6 free combination: offers all types of configurations which fit to every application. Free choice: type of each functional unit. Free choice:
More informationSM6. instructions for use. GAM cubicle (1250A) MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use GAM cubicle (1250A) foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric
More informationSM6. instructions for use. SM cubicle. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use SM cubicle foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric service
More informationThe Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs
[ MV Air-insulated Switchgear Range ] 1 PIX CUSTOMER BENEFITS Compact, versatile and highly reliable designs Choice of vacuum or SF6 switching technology Wide range of applications Enhanced operator safety
More information0MV vacuum circuit breaker. 0Evolis 24 kv. 0User 0Manual. Creation Printed on 2008/07/17
0MV vacuum circuit breaker 0Evolis 24 kv 0User 0Manual 02008 07897530EN-C0.book Page 1 Jeudi, 15. mai 2008 11:34 11 Contents Evolis description 2 Front view circuit breaker 2 Front view lateral circuit
More informationMedium Voltage Distribution FBX. Assembling a 1250A busbar Instructions.
Medium Voltage Distribution FBX Assembling a 1250A busbar Instructions www.schneider-electric.com Contents Introduction... 3 Our Service Unit: our specialists, and suitably adapted services...... 3 Overview...
More informationPIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution
Medium Voltage Distribution PIX Withdrawable Voltage Transformer Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual Nr. Edition 11/2011 www.schneider-electric.com Schneider
More informationSM6. instructions for use. IMB cubicle without earthing switch. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use IMB cubicle without earthing switch foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the
More informationTeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications
TeSys Enclosed Starters Let TeSys ensure safety in your simple motor applications TeSys Innovative and intuitive solutions to protect, monitor and control The TeSys range is suitable for motor and power
More informationSM6. instructions for use. DMVL cubicle. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use DMVL cubicle foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric service
More informationCBGS-0. Medium voltage distribution
Medium voltage distribution CBGS-0 Gas Insulated metal-enclosed Switchgear SF6 circuit breaker technology Up to 24/36 kv - 1250/1600/2000 A - 25/31.5 ka Transmission Wind Airports Oil & Gas Mining & Distribution
More informationTeSys Enclosed Starters. Let TeSys watch over your machinery
TeSys Enclosed Starters Let TeSys watch over your machinery Standard offer applications: Fans, blowers, ventilators Pumps: water pumps, heat pumps, etc. Compressors Elevators Automatic gates, roof window
More informationSM6. instructions for use. QMB cubicles. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use QMB cubicles foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric service
More informationGHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel
Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Switchgear extension and replacement of a panel During this work, essential parts of the switchgear remain in operation No. AGS 535 066-01 Edition
More informationGalaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)
Installation 990 91076 001 12/2017 Galaxy VX Battery Breaker Trip Board (GVXBBTB) and The battery breaker trip board is the interface from the battery bank to the UPS battery auxiliary inputs/outputs and
More informationSoft starters Altistart 01 The starting solution
Soft starters Altistart 01 The starting solution For single-phase and 3-phase asynchronous motors from 0.37 to 75 kw /3to85A. Altistart 01 Welcome to the Simply Smart* world, compliments of Telemecanique...
More informationMedium Voltage Distribution Maintenance Guide I 2013 Premset. 15 kv compact modular vacuum switchgear with Shielded Solid Insulation System
Medium Voltage Distribution Maintenance Guide I 2013 Premset 15 kv compact modular vacuum switchgear with Shielded Solid Insulation System Schneider Electric Services, by your side all day long Installation
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationMedium Voltage Distribution PIX kv. Additional equipment Instructions.
Medium Voltage Distribution PIX 12-17.5-24 kv Additional equipment Instructions www.schneider-electric.com Contents 1 Schneider Electric at your service... 4 1.1 Your contacts... 4 2 State of delivery
More informationSM6. instructions for use. DMV S cubicle. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use DMV S cubicle foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric
More informationSimple and smart power factor correction
Simple and smart power factor correction VarSet Low voltage capacitor banks VarSet I 2 Do you need an easy solution to immediately boost your facility s energy efficiency and productivity? Are products
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationSM6. instructions for use. DM1 S cubicle. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use DM1 S cubicle foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric
More informationSM6. instructions for use. DMV A---DMV D cubicle (1250A range) MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use DMV A---DMV D cubicle (1250A range) foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the
More informationSFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker
SFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker Instructions for use 07897543EN01 Rev.04 11/2017 SFset- Instructions for use Table of contents Presentation Presentation...
More informationSM6. instructions for use. IMCandQMCcubicles. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use IMCandQMCcubicles foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric
More informationElectrical network management. Schneider Electric. Acti 9 iem2000 Technical Datasheet
Electrical network management Schneider Electric Acti 9 iem2000 Technical Datasheet PB110836 PB108401 The Acti 9 iem2000 and iem2100 Series offer a cost-attractive, competitive range of single-phase DIN
More informationElectrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices
Electrical distribution and safety for homes Catalogue 2013 SquareD Consumer units and protection devices SquareD EL Elegance and safety in perfect harmony 2 Innovation in residential switchboards Attractive
More informationSoft starters Altistart 01 The starting solution
Soft starters Altistart 01 The starting solution For single-phase and 3-phase asynchronous motors from 0.37 to 75 kw / 3 to 85 A. Altistart 01 Welcome to the Simply Smart* world, compliments of Telemecanique...
More informationGalaxy 300 Battery Breaker Kit G3HTBKIT1
Installation 990 5739 001 03/2016 990 5739 001 Galaxy 300 Battery Breaker Kit G3HTBKIT1 What s in This Document Important Safety Instructions SAVE THESE INSTRUCTIONS...1 Safety Precautions...2 Specifications...4
More informationGalaxy Receiving and Unpacking 09/
Galaxy 5500 20 120 kva 400 V Receiving and Unpacking 09/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS
More informationVariable speed drives Altivar 31 High performance. instinctively! For 3-phase asynchronous motors from 0.18 to 15 kw
Variable speed drives Altivar 31 High performance instinctively! For 3-phase asynchronous motors from 0.18 to 15 kw Welcome to the Simply Smart* world compliments of Telemecanique... The Altivar 31 opens
More informationHVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015
Medium Voltage Distribution Catalogue 205 HVX Series 36 kv Medium Voltage Vacuum circuit breaker Fixed, middle rolling and floor rolling ranges of circuit breaker and disconnector Make the most of your
More informationSchneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant
Schneider Electric PV Skid Optimized solar power conversion system tailored to enhance any North American PV power plant 1 PV Skid solution Integrated solution designed for optimal performance in any environment
More informationThe PowerLogic wireless range is designed to retrofit existing switchboards, and enhance energy efficiency of buildings in operation for many years.
em4300 series The PowerLogic wireless range is designed to retrofit existing switchboards, and enhance energy efficiency of buildings in operation for many years. It achieves this by monitoring energy
More informationPower Supplies & Transformers Phaseo Bring energy to your automated systems!
Power Supplies & Transformers Phaseo Bring energy to your automated systems! Simply Smart! Leveraging ingenuity and intelligence for ease of use Power Supplies Universal range single/three-phase 100-500
More informationVariable speed drives Altivar 21 Stimulate your HVAC. solutions! For 3-phase asynchronous motors from 0,75 to 75 kw
Variable speed drives Altivar 21 Stimulate your HVAC solutions! For 3-phase asynchronous motors from 0,75 to 75 kw Simply Smart! Leverage ingenuity and intelligence for ease of use The essential connection
More informationIdentify electrical hazards and operation on an electrical installation. Valhabilis
Identify electrical hazards and operation on an electrical installation Valhabilis 1. Presentation of the Equipment The Valhabilis equipment is made up of two complementary cases representing an electrical
More informationBC IMPREGO Impregnated dry type transformers and autotransformers
atalogue B IMPREGO Impregnated dry type transformers and autotransformers Low Voltage Distribution schneider-electric.com LV transformers and autotransformers Tailored to your needs ontents Your requirements
More informationMotor management system TeSys T Give your motor starters a sixth sense!
The efficiency of Telemecanique branded solutions Used in combination, Telemecanique products provide quality solutions, meeting all your Automation & Control applications requirements. Motor management
More informationProtection and control VIP30, VIP35. Relays technical manual
Protection and control VIP30, VIP35 Relays technical manual contents 1. presentation of the VIP30 and VIP35...3 2. use and settings...4 3. sensors and operating ranges... 4. connection scheme...9 5. assembly
More informationSymmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.
Symmetra PX 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V Receiving and Unpacking 01/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks
More informationGalaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.
Galaxy 3500 10-40 kva 3:3 and 3:1 Receiving and Unpacking 380/400/415 and 208/220 V 04/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider
More informationLow Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM
Low Voltage Systems MNS BS - front & rear access switchboards Tested, tried & trusted solutions Power and productivity for a better world TM MNS BS Tested, tried and trusted MNS - Global system design
More informationSecondary Distribution Switchgear FBX. SF6 Gas-insulated switchboards. Instructions Operation - Maintenance
Secondary Distribution Switchgear FBX SF6 Gas-insulated switchboards Instructions Operation - Maintenance Contents 1 Schneider Electric at your service................... 1 1.1 Our Service Unit: our specialists,
More informationat a reduced size!...
Telemecanique Altivar 11 Real efficiency at a reduced size!... Altivar 11 variable speed drives for asynchronous motors from 0.18 to 2.2 kw Building a New Electric World Altivar 11 : The little one with
More informationSolutions. for large buildings and power plants
s for large buildings and power plants Renewable energy from solar panels s for photovoltaic arrays In recent years photovoltaic electricity generation has met the growing demand for energy. There is a
More informationStudy and operate the protection features associated with the neutral plans with manual troubleshooting. S.L.T.-TR22 Bench
Study and operate the protection features associated with the neutral plans with manual troubleshooting S.L.T.-TR22 Bench 1. Presentation of the kit This bench illustrates the rationale underlying the
More informationThe vacuum circuit breaker for commercial buildings, industrial plants and utilities
The vacuum circuit breaker for commercial buildings, industrial plants and utilities EasyPact EXE The easy choice for more value 2 EasyPact EXE EasyPact EXE, a medium voltage vacuum circuit breaker optimizing
More informationUniGear. Technical Guide
UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating
More informationFloor outlet boxes British Standard
Mita floor boxes British Standard Product catalogue 2009 P117622 Mita floor boxes > + High capacity Quick-Fix function Pre-wired options Provision for RCD protection All plastic parts are halogen-free
More informationDim your energy consumption
Dim your energy consumption Less energy and more comfort with new solutions P121220 Dimmer as an energy saver? Lighting makes up 40% of the energy consumption in private homes P121135 2 Energy efficiency
More informationCircuit-Breaker Design
8PT2751 CircuitBreaker Design Contents Page ACB Circuitbreaker design with 3W. Incoming feeder, couplers and outgoing feeder cubicles 4/2 General 4/2 Structure and Functions 4/2 Auxiliary Compartment 4/2
More informationThe switchboard that your installation deserves
The switchboard that your installation deserves Blokset : Low voltage switchboard for electrical distribution and motor control 2 A tried and tested switchboard Blokset switchboards have long guaranteed
More informationMedium Voltage Distribution Catalogue Flusarc Make the most of your energy
Medium Voltage Distribution Catalogue 2012 Flusarc 40.5 Make the most of your energy Flusarc switchgear 40.5 kv - 630 A - 20 ka General contents Overview 3 General characteristics 7 Description 11 Installation
More informationCertified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers
Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind
More informationMetal Clad Switchgears
SNC Series Metal Clad Switchgears > up to 36 kv Rated Voltage > up to 2500 A Rated Current > up to 40 ka Rated Short Time Withstand Current > LSC-2B, PM, AFLR > In Confirmity with IEC 62271-1, 100, 102,
More informatione 2 ALPHA Medium Voltage Switchgear K Catalogue EN
e 2 ALPHA Medium Voltage Switchgear K-1.2.3 Catalogue EN WE CREATE IDEAS WITH POWER! ELEKTROMETAL ENERGETYKA SA provides solutions for electrical power engineering. Our services are carried out by a team
More informationPIX-H Metal-clad switchgear up to 17.5kV
AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...
More informationMedium Voltage Switchgear. Gas-Insulated switchgear up to 36 kv. Operation - Maintenance Technical Instruction. No. AGS
Medium Voltage Switchgear WS Gas-Insulated switchgear up to 36 kv Operation - Maintenance Technical Instruction No. AGS 53 59-0 Edition 04/203 www.schneider-electric.com Manufacturer: Schneider Electric
More informationAdak Behin Niroo. co.com
Adak Behin Niroo www.adakbn co.com PRODUCTS LOW VOLTAGE SWITCHGEARS MEDIUM VOLTAGE SWITCHGEARS PRODUCTS LOW VOLTAGE SWITCHGEARS www.adakbn co.com High Standard Type Tested Know How
More informationWiring devices Asfora 2015 catalogue
Wiring devices 05 catalogue Contents Presentation Products with cover frame (white, cream) Switches and push-buttons 6 Socket-outlets 8 Communication outlets 9 Dimmers 0 ccessories Products without cover
More information33KV INDOOR SWITCHGEAR
33KV INDOOR SWITCHGEAR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:
More informationOperating conditions. Generalities. Normal operating conditions
Generalities Operating conditions In addition to its technical characteristics, SM6 meets requirements concerning safety of life and property as well as ease of installation, operation and protecting the
More informationMEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV
CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection
More informationGalaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/
Galaxy VM Installation GVMMODBCW, GVMMODBCN 09/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred
More informationSecondary Distribution Switchgear FBX. SF6 Gas-insulated switchboards CB function. Instructions Installation - Commissioning Operating - Maintenance
Secondary Distribution Switchgear FBX SF6 Gas-insulated switchboards CB function Instructions Installation - Commissioning Operating - Maintenance Contents 1 Schneider Electric at your service... 1 1.1
More informationGAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura
GAE CLAD \ METALCLAD SWITCHGEAR up to 24 kv \ M600204.15 PT Guna Era Manufaktura Catalogue 2015 GAE CLAD Vacuum Circuit Breaker With Embedded Poles Metal - Clad Switchgear Up To 24 kv General Description
More informationMedium-Voltage Switchgear and Switches
edium-voltage Switchgear and Switches G edium-voltage Switchgear up to 6 kv, 2.500A Product overview Switchgear for primary distribution level type CPG.0, CPG.1, AC Switchgear for secondary distribution
More informationExiway Easyled. Emergency lighting
Exiway Easyled So Emergency lighting Exiway Easyled Contents Exiway Easyled Presentation 4 Technical specifications 8 Product catalogue numbers 8 Accessories 10 Spare parts 11 Dimensions 11 Technical
More informationMedium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU
Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal
More informationEnergy Australia Chamber Substation indoor switchgear. installation,operation and maintenance instructions version 1.
Energy Australia Chamber Substation indoor switchgear installation,operation and maintenance instructions version 1.6 / February 2009 1 Details of revision Version Comment Date 1.0 First Draft Issue May
More information10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36
10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36 Gdańsk, October 2015 Improving the competitiveness of the company ELMOR through investments introducing
More information24 kv. A brief summary of the. range
Medium-Voltage distribution - 24 kv Metal-enclosed withdrawable switchgears MCset4 - SF6 technology NEX24 - vacuum technology 2008 Maintenance and Services Guide October 2008 PE90002 24 kv A brief summary
More informationMCCB Plug-in Chassis Type HBC
MCCB Plug-in Chassis Type HBC Low Voltage Switchboard Equipment Publication HBC 2015 Since product improvement is a continuing policy, we reserve the right to change specifications without notice. Contents
More informatione 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN
e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K-11.1.2 Catalogue EN We Create Ideas With Power! e 2 ALPHA-2S double busbar switchgear is designed for use in primary and secondary electric energy
More informationREMOVAL AND INSTALLATION
303-03-1 Engine Cooling 303-03-1 REMOVAL AND INSTALLATION Radiator, Cooling Fan and Shroud Special Tool(s) Wrench, Fan Clutch Nut 303-240 (T84T-6312-D) Holding Wrench, Fan Pulley 303-239 (T84T-6312-C)
More informationElectrical network protection VIP30, VIP35. User s manual 12/2008
Electrical network protection VIP30, VIP35 User s manual 1/008 Safety instructions ANSI symbol. IEC symbol. Safety symbols and messages Read these instructions carefully and look at the equipment to become
More informationMaximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops
Maximize your ROI Conext CL-60 String Inverter The ideal solution for decentralized power plants and commercial rooftops solar.schneider-electric.com 2016 Schneider Electric. All rights reserved. All trademarks
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT
An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:
More informationCubicles Frameworks. Enclosures W=400mm. System P. 400 mm deep framework. 600 mm deep framework. Hinged front plate support frame.
Frameworks DD380800 400 mm deep framework DD380572 DD380573 DD380574 08407. Framework width W = 300 mm 08403 W = 400 mm 08404 W = 650 mm 08406 W = 800 mm 08408 W = 800 mm (650 + 150) 08407 b composition
More informationMinera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards
Minera Oil distribution transformers up to 3 150 kva Minera at a glance Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: Hermetically sealed with integral
More information(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:
10111. 4711M1 An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY Corrigendum 1
More informationSchneider Electric Conext SW
Schneider Electric Inverter/Charger Applications for the New Value in off-grid solar and backup power solutions Conext TM SW delivers new value and a new price point to the marketplace in 2013. is a pure
More informationFuse contactor drawer CVX for PIX Switchgear (12kV)
Medium Voltage Distribution Fuse contactor drawer CVX for PIX Switchgear (12kV) Operating Instruction NTV133 Edition 09/09 Important Note The Operating Instructions, which are exclusively valid, are always
More informationGreen approach to fuel savings
Green approach to fuel savings Schneider Electric PV Hybrid solution in cooperation with DEIF This solution offers high PV penetration over diesel power generation with superior installation flexibility
More informationATLV MaxSG. Low Voltage Metal Enclosed Switchgear
ATLV MaxSG Low Voltage Metal Enclosed Switchgear ABB, INC. Product General Description MaxSG Switchgear ABB MaxSG switchgear is a further continuation in the development of innovative products from ABB,
More informationSchneider Electric Powering the U.S. Department of Energy Solar Decathlon 2011
Schneider Electric Powering the U.S. Department of Energy Solar Decathlon 2011 Washington D.C., U.S.A. Make the most of your energy sm Schneider Electric: Proud sustaining sponsor of the U.S. Department
More informationYour TeSys guide. TeSys Advanced. new. TeSys Rotary Handle for TeSys GV2 and GV3 circuit breakers and TeSys U starters.
TeSys Advanced Your TeSys guide Up to 32 A Up to 38 A Up to 65 A Up to 800 A TeSys Rotary Handle LUCB or LUCD.. LUCM LR97D LT47 LT3 LTMR new TeSys Rotary Handle for TeSys GV2 and GV3 circuit breakers and
More informationAIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE
AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly
More informationcircuit-- breaker instructions for use SF1 fixed or in SM6 circuit --- breaker MV distribution circuit breaker at your service Anglais
circuit-- breaker Anglais MV distribution circuit breaker at your service instructions for use SF1 fixed or in SM6 circuit --- breaker foreword... 3 symbols and conventions... 3 as per iso 3864---2...
More informationUniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard
UniSafe 36 Medium voltage, arc-proof, air-insulated, metal-clad switchboard CHARACTERISTICS AND APPLICATIONS DESCRIPTION APPARATUS SWITCHBOARD CHARACTERISTICS REF 542 PLUS UNIT INSTRUMENT TRANSFORMERS
More informationMNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems
MNS Light F Low-voltage switchgear with fixed units ABB LV Systems Cubicle design MNS Light F switchgear is a flexible system with a large selection of cubicle variants that can be built together in optional
More informationCustomized drive solutions
Customized drive solutions Low-Voltage Drive Systems Ready-to-use from 0.75 1200 kw schneider-electric.com/drives 2 schneider-electric.com/drives schneider-electric.com/drives 3 What will you get with
More information