1 Identify electrical hazards and operation on an electrical installation Valhabilis
2
3 1. Presentation of the Equipment The Valhabilis equipment is made up of two complementary cases representing an electrical installation of an equipment room. It allows to introduce the accreditation of electrical hazards and to perform operations. 1.1 Overview This equipment comes in the form of two cases: The first case Electrical distribution includes a small electric board supplying standard plugs for measuring and connection work. The second case motor starter is supplied by the first case. As an example, the motor starter simulates a ventilation system, and the students can perform checking and maintenance operations of the electrical circuit in compliance with relevant standards. A kit (optional) containing a no-voltage multimeter, a padlocking device, and PPE (Personal Protective Equipment insulating gloves, face guard), is used to perform operations in compliance with relevant standards. 3/17
4 1.2 Characteristics Mechanical data Dimensions of both cases: Height: 450 mm Width: 390 mm Depth: 310 mm Weight of distribution case: 10 kg Weight of Motor Starter case: 13 kg Electrical data Power supply: 230 Vac (± 10 %) Frequency: 50 Hz ± 5 % Input power: 50 VA Rated surge withstand voltage: 2.5 kv Electric shock protection class: I (according to standard IE ) Installation class: II Measuring class: I (according to standard IE ) 4/17
5 Technical data of the main components Case Electrical distribution It contains a case with a cover that provides locations for accessories storage and electrical equipment installed on a white Lamica plate. This electrical equipment is fitted with a small electric board with a 16A main 30mA differential circuit breaker This main circuit breaker protects three outputs: two house plugs and one plug for the Motor Starter kit. The first 10A circuit breaker protects a house plug and the output fitted with a cable gland plate located below. The second 10A circuit breaker only protects the second house plug. At bottom left, there is the 2P + Earth stub for main supply that is fitted with a red light On/Off switch. A 2-position key selector named without phase allows to reverse the neutral and the phase on the supply. A left spring return key selector named Differential defect allows when it is in right position to proceed to a differential test of the main circuit breaker. Circuit breakers Selectors Supply input and switch 5/17
6 The motor starter case contains the following equipment: A lockable separator switch A kit of load bars fitted with a protection plate. A protection thermal magnetic circuit breaker. A contactor with auxiliary contacts additive. Two loops to perform current measurements. The power cable single-line diagram that represents the motor starter. A 1A circuit breaker for the protection of the control circuit. A fuse holder that only protects the green indicator of the push button. This fuse holder is fitted with a 8,5x23 2Agf fuse, the nine others are provided with the equipment in their original package. Several control indicator lights. A green illuminated push button named On. One key mushroom emergency stop button. An electrical motor simulating a fan. Lockable switch 1A circuit breaker and fuse holder Kit of load bars Illuminated indicators Push button Mushroom stop button Motor Thermal magnetic circuit breaker Contactor Single-line diagram Measureing loops 6/17
7 1.3 Main functions The equipment is made up of two cases designed for the simulation of an electrical installation. They allow to familiarise non-electro-technical high school students with the accreditation of electrical hazards. The introduction to the accreditation allows to perform B0V and B1V operations for Energy and Fluid in Industrial Maintenance or Electronic fields. A non electrical operation in vicinity zone. A connection operation in the vicinity of live parts. A setting and measuring operation. A replacing operation. An operation following a failure on a control or power circuit. A commissioning of the equipment. 7/17
8 2. Teaching 2.1 Presentation of teaching The aim of this equipment is to identify and to increase the users awareness of electrical hazards and to train in operations of levels B0V and B1V. The subjects that can be handled are: A non electrical operation in vicinity zone. A connection operation in the vicinity of live parts. A setting and measuring operation. A replacing operation. An operation following a failure on a control or power circuit. A commissioning of the equipment. It is intended for the following channels: PROFESSIONAL UNIVERSITY SCHOOL LOWER HIGH SCHOOL SECTION HIGH SCHOOL Automation systems and IT for industrial systems Electrical engineering Mechanical engineering The hands-on exercises that can be carried out using the Valhabilis teaching equipment consist of a teacher's document with answers and a trainee document. Exercise list: Ex1: Level B0V-T1 Objective: Reset on order a protection device in a live electrical cabinet. Ex2: Level B0V-T2 Objective: Perform non-electrical operations inside a live electrical cabinet. Ex3: Level B0V-T1 and T2 Objective: T1 : Reset on order a protection device in a live electrical cabinet. T2 : Perform non-electrical operations inside a live electrical cabinet. Ex4: Level B1V-T1 Objective: Perform electrical operations in vicinity zone. Ex5: Level B1V-T2 Objective: Perform electrical operations out of the vicinity zone after insulation. Ex6: Level B1V-T4 Objective: Measure electrical values. 8/17
9 Ex7: Level B0V-T1-T2-T3-T4 Objective: T1 : Perform electrical operations in the vicinity zone. T2 : Perform electrical operations out of the vicinity zone after insulation. T3 : Watch over the electrical safety of people. T4 : Measure electrical values. 9/17
10 2.2 Teaching examples 10/17
11 11/17
12 12/17
13 13/17
14 14/17
15 15/17
16 16/17
17 3. Elements supplied with the equipment 3.1 Equipment supplied The Valhabilis assembly, reference MD1AA630 is composed with: An Electrical distribution case, A Motor starter case, A mains supply cable 2P + Earth, Two protections of bars kit (one is installed on the case), A box with nine 2A Gf fuses (one is installed on the fuse holder), Four contact blocks additive 2 F, A kit of insulation device for MG circuit breaker, A cable with a receptacle 2P + Earth. Option: A kit of safety material, reference MD1AG630, containing: All the material included in the reference MD1AA630, A blocking padlocking, A pair of gloves, A face guard, A VAT CA760 CHAUVIN ARNOUX with measuring cables. 3.2 Equipment not supplied All other items that are not listed in the paragraph "equipment supplied". 3.3 Documents A technical manual, reference MD1AD631EN. An exercise manual, reference MD1AD632EN. 4. Contact Schneider Electric France Activité Didactique 3F 35 rue Joseph Monier CS Rueil Malmaison - France FR-didactic@fr.schneider-electric.com 17/17
Study and operate the protection features associated with the neutral plans with manual troubleshooting. S.L.T.-TR22 Bench
Study and operate the protection features associated with the neutral plans with manual troubleshooting S.L.T.-TR22 Bench 1. Presentation of the kit This bench illustrates the rationale underlying the
More informationTeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications
TeSys Enclosed Starters Let TeSys ensure safety in your simple motor applications TeSys Innovative and intuitive solutions to protect, monitor and control The TeSys range is suitable for motor and power
More informationTeSys Enclosed Starters. Let TeSys watch over your machinery
TeSys Enclosed Starters Let TeSys watch over your machinery Standard offer applications: Fans, blowers, ventilators Pumps: water pumps, heat pumps, etc. Compressors Elevators Automatic gates, roof window
More informationGalaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)
Installation 990 91076 001 12/2017 Galaxy VX Battery Breaker Trip Board (GVXBBTB) and The battery breaker trip board is the interface from the battery bank to the UPS battery auxiliary inputs/outputs and
More informationI B D Q I B D Q O I B D Q O
Extension offer: new possible combinations 2 and 3 functions RM6 free combination: offers all types of configurations which fit to every application. Free choice: type of each functional unit. Free choice:
More informationMCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution
Medium Voltage Distribution MCset 17.5 kv ir insulated switchboard Withdrawable switchgear SF6 or vaccum technology Civil engineering guide pril 2012 Contents General 2 Glossary 2 Dimensions and weights
More informationEVlink Parking EVF1 - EVW1
EVlink Parking EVF1 - EVW1 Parking Charging Stations User Manual 07/2013 EVF1ppppppp EVW1ppppppp DOCA0063EN-01 www.schneider-electric.com This document contains general descriptions and/or general technical
More informationBC IMPREGO Impregnated dry type transformers and autotransformers
atalogue B IMPREGO Impregnated dry type transformers and autotransformers Low Voltage Distribution schneider-electric.com LV transformers and autotransformers Tailored to your needs ontents Your requirements
More informationThe Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs
[ MV Air-insulated Switchgear Range ] 1 PIX CUSTOMER BENEFITS Compact, versatile and highly reliable designs Choice of vacuum or SF6 switching technology Wide range of applications Enhanced operator safety
More informationGalaxy VM. Battery Breaker Box Installation 09/
Galaxy VM Battery Breaker Box Installation 09/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred
More informationHVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015
Medium Voltage Distribution Catalogue 205 HVX Series 36 kv Medium Voltage Vacuum circuit breaker Fixed, middle rolling and floor rolling ranges of circuit breaker and disconnector Make the most of your
More informationSchneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant
Schneider Electric PV Skid Optimized solar power conversion system tailored to enhance any North American PV power plant 1 PV Skid solution Integrated solution designed for optimal performance in any environment
More informationElectrical network protection VIP30, VIP35. User s manual 12/2008
Electrical network protection VIP30, VIP35 User s manual 1/008 Safety instructions ANSI symbol. IEC symbol. Safety symbols and messages Read these instructions carefully and look at the equipment to become
More informationBOXES, ENCLOSURES, SHELTERS & KIOSKS FOR SOLAR APPLICATIONS
BOXES, ENCLOSURES, SHELTERS & KIOSKS FOR SOLAR APPLICATIONS Boxes, enclosures, shelters and kiosks designed according to customer need, conceived for every type of solar application: * Grid connected Installation
More informationGHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel
Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Switchgear extension and replacement of a panel During this work, essential parts of the switchgear remain in operation No. AGS 535 066-01 Edition
More informationSoft starters Altistart 01 The starting solution
Soft starters Altistart 01 The starting solution For single-phase and 3-phase asynchronous motors from 0.37 to 75 kw / 3 to 85 A. Altistart 01 Welcome to the Simply Smart* world, compliments of Telemecanique...
More informationGalaxy 300 Battery Breaker Kit G3HTBKIT1
Installation 990 5739 001 03/2016 990 5739 001 Galaxy 300 Battery Breaker Kit G3HTBKIT1 What s in This Document Important Safety Instructions SAVE THESE INSTRUCTIONS...1 Safety Precautions...2 Specifications...4
More informationCBGS-0. Medium voltage distribution
Medium voltage distribution CBGS-0 Gas Insulated metal-enclosed Switchgear SF6 circuit breaker technology Up to 24/36 kv - 1250/1600/2000 A - 25/31.5 ka Transmission Wind Airports Oil & Gas Mining & Distribution
More informationSecondary Distribution Switchgear FBX. SF6 Gas-insulated switchboards CB function. Instructions Installation - Commissioning Operating - Maintenance
Secondary Distribution Switchgear FBX SF6 Gas-insulated switchboards CB function Instructions Installation - Commissioning Operating - Maintenance Contents 1 Schneider Electric at your service... 1 1.1
More informationSchneider Electric Conext SW
Schneider Electric Inverter/Charger Applications for the New Value in off-grid solar and backup power solutions Conext TM SW delivers new value and a new price point to the marketplace in 2013. is a pure
More informationMedium Voltage Distribution FBX. Assembling a 1250A busbar Instructions.
Medium Voltage Distribution FBX Assembling a 1250A busbar Instructions www.schneider-electric.com Contents Introduction... 3 Our Service Unit: our specialists, and suitably adapted services...... 3 Overview...
More informationDOCA /2015. TeSys H. Motor Starter User Guide 08/2015 DOCA0111EN-00.
TeSys H DOCA0111-00 08/2015 TeSys H Motor Starter User Guide 08/2015 DOCA0111EN-00 www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical
More informationR820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017
R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating
More informationMCset kv Medium voltage equipment
Maintenance Guide PE90014 PE90006 MCset 1-2 - 3 17.5 kv Medium voltage equipment Air-insulated switchboards Metal-enclosed switchgear with moving parts PE90007 PE90008 PE90009 PE90007 Maintenance Guide
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationABB s new control and protection devices
ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for
More informationDim your energy consumption
Dim your energy consumption Less energy and more comfort with new solutions P121220 Dimmer as an energy saver? Lighting makes up 40% of the energy consumption in private homes P121135 2 Energy efficiency
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationSFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker
SFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker Instructions for use 07897543EN01 Rev.04 11/2017 SFset- Instructions for use Table of contents Presentation Presentation...
More informationEBS PRODUCTS
EBS PRODUCTS WWW.ebsproducts.com OPERATIONS MANUAL EPG-1 Power Steering - Gear Oil Fluid Service Equipment #1000-0060 1-1-16 TABLE OF CONTENTS I. SAFETY INFORMATION... 2 1.01 IMPORTANT SAFETY NOTICE...
More informationPIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution
Medium Voltage Distribution PIX Withdrawable Voltage Transformer Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual Nr. Edition 11/2011 www.schneider-electric.com Schneider
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationElectrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices
Electrical distribution and safety for homes Catalogue 2013 SquareD Consumer units and protection devices SquareD EL Elegance and safety in perfect harmony 2 Innovation in residential switchboards Attractive
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationSecondary Distribution Switchgear FBX. SF6 Gas-insulated switchboards. Instructions Operation - Maintenance
Secondary Distribution Switchgear FBX SF6 Gas-insulated switchboards Instructions Operation - Maintenance Contents 1 Schneider Electric at your service................... 1 1.1 Our Service Unit: our specialists,
More information8036-A0 Motor Drives Training System (Stand-Alone)
8036-A0 Motor Drives Training System (Stand-Alone) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Table of
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationGalaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.
Galaxy VM Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks
More informationGalaxy Receiving and Unpacking 09/
Galaxy 5500 20 120 kva 400 V Receiving and Unpacking 09/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS
More informationElectrical network management. Schneider Electric. Acti 9 iem2000 Technical Datasheet
Electrical network management Schneider Electric Acti 9 iem2000 Technical Datasheet PB110836 PB108401 The Acti 9 iem2000 and iem2100 Series offer a cost-attractive, competitive range of single-phase DIN
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationR.C.B.O. SP / 1 module
87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...
More informationNEX - 24 kv Withdrawable Circuit Breaker
Air Insulated Medium Voltage Equipment NEX - 24 kv Withdrawable Circuit Breaker Installation drawings file Contents bj Fitting the upper main busbars 1250 A busbar - 800 mm cubicle Assembly 1250 A busbar
More informationIndustrial Controls Training Systems
Industrial Controls Training Systems LabVolt Series Datasheet Festo Didactic en 220 V - 50 Hz 04/2018 Table of Contents General Description 2 Integration into 8001 and 8006 Electromechanical Training Systems
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More informationSoft starters Altistart 01 The starting solution
Soft starters Altistart 01 The starting solution For single-phase and 3-phase asynchronous motors from 0.37 to 75 kw /3to85A. Altistart 01 Welcome to the Simply Smart* world, compliments of Telemecanique...
More informationMedium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient
Medium voltage NEX switchgear Withdrawable circuit breaker Quite simply efficient NEX, a simple and flexible solution NEX is the result of worldwide acquired experience and provides you with a high level
More informationIntelligent Choice for Prestigious Buildings
Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationTeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com
TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic
More informationMotor Drives Training System (Stand-Alone, 120 V Version) (8036-C0)
Motor Drives Training System (Stand-Alone, 120 V Version) 581526 (8036-C0) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 11/2018 Table of Contents General Description 2 List of Equipment 2 List
More informationSimple and smart power factor correction
Simple and smart power factor correction VarSet Low voltage capacitor banks VarSet I 2 Do you need an easy solution to immediately boost your facility s energy efficiency and productivity? Are products
More informationComponents for EEx e Panels
Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37
More informationMCset 4-24 kv Withdrawable SF6 circuit breaker
Medium Voltage switchgear MCset 4-24 kv Withdrawable SF6 circuit breaker Instruction for use Contents General 2 Glossary 2 Symbols 2 Recommendations 3 General description 4 AD4 unit 4 AD4 unit with toroidal
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationSM6. instructions for use. IMB cubicle without earthing switch. MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use IMB cubicle without earthing switch foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationIndustry Automation Control Components
Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements
More informationMedium Voltage Distribution Maintenance Guide I 2013 Premset. 15 kv compact modular vacuum switchgear with Shielded Solid Insulation System
Medium Voltage Distribution Maintenance Guide I 2013 Premset 15 kv compact modular vacuum switchgear with Shielded Solid Insulation System Schneider Electric Services, by your side all day long Installation
More informationSM6. instructions for use. GAM cubicle (1250A) MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use GAM cubicle (1250A) foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric
More informationThermal magnetic and trip-free switches
87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/
More informationWUEKRO. Training & Didactic Systems. Protection Schemes DIN VDE 0100
Training & Didactic Systems Protection Schemes DIN VDE 0100 Catalog WA2E/08 Table of Contents Page Our Services, Customers and Scope of Supply 2 Introduction 4 Protection Schemes according to DIN VDE 0100
More informationMaximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops
Maximize your ROI Conext CL-60 String Inverter The ideal solution for decentralized power plants and commercial rooftops solar.schneider-electric.com 2016 Schneider Electric. All rights reserved. All trademarks
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informationCertified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers
Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationMinera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards
Minera Oil distribution transformers up to 3 150 kva Minera at a glance Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: Hermetically sealed with integral
More informationCustomized drive solutions
Customized drive solutions Low-Voltage Drive Systems Ready-to-use from 0.75 1200 kw schneider-electric.com/drives 2 schneider-electric.com/drives schneider-electric.com/drives 3 What will you get with
More informationReliable. Let TeSys be your drive. Protection. Available. Connected. Compliant. Smart. Overview of solutions to protect, monitor and control
Let TeSys be your drive Overview of solutions to protect, monitor and control Flexible Safety Smart Connected Protection Compliant Energy efficiency Reliable Available TeSys Advanced Up to 32 A Up to 38
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationAccelerate your grid modernization with smart RMUs. Ring main units with smart grid-ready feeder automation
Accelerate your grid modernization with smart RMUs Ring main units with smart grid-ready feeder automation schneider-electric.com/smart-rmu Contents > Take charge of your grid evolution For deployment
More informationUV Transilluminator Dual Wavelength (Large)
BT505 A Geno Technology, Inc. (USA) brand name UV Transilluminator Dual Wavelength (Large) Cat. No. BT505 1-800-628-7730 1-314-991-6034 info@btlabsystems.com INTRODUCTION BT Lab Systems UV Transilluminators
More informationTable of Contents. For latest version, visit:
Table of Contents 1.0 Introduction... 1.0 Overview... 1 3.0 Test Set Controls... 6 3.1 Power... 6 3. Time Display... 6 3.3 Timer Clear Push Button... 6 3.4 Start Push Button and LED... 6 3.5 Stop Push
More informationOutdoor vacuum breaker for railway applications - FSK II
Outdoor vacuum breaker for railway applications - FSK II Single or two-pole outdoor vacuum breaker with magnetic actuator 27.5 kv - 250 kv BIL - 1250 A. 2000 A - 25.0 ka - 50/60 Hz 27.5 kv - 200 kv BIL
More informationElectric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2011 Class 2800 CONTENTS Description............................................ Page 3 Catalog Numbering
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationMPA Chassis for Multi-Probe Magnetic Transducers
DESCRIPTION: TYPICAL APPLICATIONS: The MPA chassis is utilized for multi-probe SENIS Magnetic Field-to-Voltage Transducer system with any of SENIS Hall Probes. Characterization and quality control of permanent
More informationInstruction Manual. Standard Controller # # for
Instruction Manual for Standard Controller #510-3000 #510-3010 1. Accessories Included Accessories A. Two 2A Fuses with 115V model; Two 1A Fuses with 230V model. B. One Slide-On Handpiece Holder (#510-3130)
More informationMedium Voltage Distribution Catalogue Flusarc Make the most of your energy
Medium Voltage Distribution Catalogue 2012 Flusarc 40.5 Make the most of your energy Flusarc switchgear 40.5 kv - 630 A - 20 ka General contents Overview 3 General characteristics 7 Description 11 Installation
More informationMetal Clad Switchgears
SNC Series Metal Clad Switchgears > up to 36 kv Rated Voltage > up to 2500 A Rated Current > up to 40 ka Rated Short Time Withstand Current > LSC-2B, PM, AFLR > In Confirmity with IEC 62271-1, 100, 102,
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More informationQUALITY ASSURANCE & DOCUMENTATION
QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical
More informationCondensation monitor
QXA2101 QXA2100 Condensation monitor QXA2100 QXA2101 Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power. Can also be used with extension module AQX2000
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationMultistandard offer for OEM applications. Single solution source for business without borders
Multistandard offer for OEM applications Single solution source for business without borders 1 Improving customer satisfaction means producing industrial machines that are compliant to international standards,
More informationGalaxy Installation 08/
Galaxy 5000 40 130 kva 480 V Installation 08/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to
More informationExercise 1-1. Lockout/Tagout Procedure EXERCISE OBJECTIVE DISCUSSION. Become familiar with the Industrial Controls Training System.
Exercise 1-1 Lockout/Tagout Procedure EXERCISE OBJECTIVE Become familiar with the Industrial Controls Training System. Understand and perform proper lockout/tagout procedures during industrial servicing
More informationThe PowerLogic wireless range is designed to retrofit existing switchboards, and enhance energy efficiency of buildings in operation for many years.
em4300 series The PowerLogic wireless range is designed to retrofit existing switchboards, and enhance energy efficiency of buildings in operation for many years. It achieves this by monitoring energy
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationWORK BENCHES FOR ELECTRIC INSTALLATIONS. index
index WORK BENCHES TWO PLACE WORK BENCH WITH 2 INDEPENDENT SUPPLIES DL 1101 FOUR PLACE WORK BENCH WITH 4 INDEPENDENT SUPPLIES DL 1103 FOUR PLACE WORK BENCH WITH 2 INDEPENDENT SUPPLIES DL 1104 TWO PLACE
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationMizer Single Pump and Starter Box
Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationSDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual
SDM320D / SDM320A DIN Rail Single Phase Two Wire Energy Meter with S0 Pulse Output (Four modular) User Manual ------------------- 1.1 Safety instruction 1.2 Introductions 1.3 Performance criteria 1.4 Specifications
More information