AAMAlALIINSULATING GLASS CERTIFICATION PROGRAM

Size: px
Start display at page:

Download "AAMAlALIINSULATING GLASS CERTIFICATION PROGRAM"

Transcription

1 AAMAlALIINSULATING GLASS CERTIFICATION PROGRAM Attn: Tony Pauly NOTICE OF CERTIFICATION AUTHORIZATION Test Method: ASTM E Specification: ASTM E The sealed insulating glass described below is hereby approved for listing in the current AAMAIALI Certified Products Directory. Plant Code Sealant Desiccant Spacer (2)* Corner Low-E Gas Fill VPC-1.Hot Melt Butyl Mol. Sieve Silicone Foam Bent** Yes (E/D) Argon "Triple glazed. **Final corner sealed with Mylar tape. Test Laboratory: Dallas Laboratories, Inc. Test Report No: Date Test Completed: August 7,2013 Certification Expiration Date: August 7,2015 Date: August 8, 2013 ACP-6 (Rev. 9110)

2 Consultants and Technologists / Quality Control Engineers / Consumer Certification Programs 1323 Wall Street, P.O. Box , Dallas, Texas (214) Man ufacturer: Address: City, State, Zip Telephone No.: Attention: Tony Pauly Code: VPC-1 Date: August 7,2013 Report: Description of Test Specimen: Triple Glazed Size (width by height): Type of Spacer: Type of desiccant: Type of Sealant(s): Other Features: Manufactured Date: 14" x 20" Silicone Foam (Quanex Premium). Mol. Sieve contained in foam spacer. Hot Melt Butyl (H. B. Fuller HL-5130). Corners bent; final corner sealed with Mylar tape. Low-E glass with edge deletion. December 13,2012 TEST METHOD: ASTM E SPECIFICATION: ASTM E Initial High Weather High Argon Specimen Frost Fogging Test Humidity Cycling Humidity Concentration Number Point ASTM E Days 63 Days 28 Days ASTM E 2649"()9 (DF) (DF) (OF) ("F) Initial Final 1 <_85 f <-85 <_85 f <_85 <_85 f <_85 <_85 f <-85 96% / 97% 86% f 84% 2 <-85 / <_85 <_85 c / <_85 <_85 f <-85 <_85 f <_85 98% f 95% 89% / 82% 3 <-85 f <_85 <_85 1 <_85 <_85 / <_85 <_85 / <_85 97% /97% 87% /85% 4 <_85 / <_85 <_85 / <_85 <_85 / <-85 <-85 / <-85 98% /97% 86% / 86% 5 <_85 / <_85 <_85 / <_85 <_85 / <-85 <-85 / <-85 96%/90% 84%/86% I I 6 <-85 / <-85 <-85 / <_85 <-85 / <_85 <-85 1 <_85 95% 196% 86% f 84% I 7 8 Average: Average: 9 Passed w/grids 97% 195% 86% /85% 10 Passedw/grids These results indicate compliance with the ASTM E requirements. ALIForm 992 A HALF OF A CENTURY EXPERIENCE AVAILABLE FOR INDUSTRY

3 AAMAlALIINSULATING GLASS CERTIFICATION PROGRAM Attn: John Seba NOTICE OF CERTIFICATION AUTHORIZATION Test Method: ASTM E Specification: ASTM E The sealed insulating glass described below is hereby approved for listing in the current AAMAIALI Certified Products Directory Plant Code Sealant Desiccant Spacer Corner Low-E Gas Fill VPC-1 Hot Melt Butyl Mol. Sieve Silicone Foam Bent* Yes (E/O) Argon L *Final corner sealed with Mylar tape. Test Laboratory: Dallas Laboratories, Inc. Test Report No: Date Test Completed: July 17, 2013 Certification Expiration Date: July 17, 2015 Date: July 19, 2013 ACP-6 (Rev. 9/10)

4 Consultants and Technologists / Quality Control Engineers / Consumer Certification Programs 1323 Wall Street, P.O. Box , Dallas, Texas (214) Manufacturer: Address: City, State, Zip Telephone No.: Attention: John Seba Code: VPC-1 Date: July 17, 2013 Report: Description of Test Specimen: Set 1 Size (width by height): Type of Spacer: Type of desiccant: Type of Sealant(s): Other Features: Manufactured Date: 14" x 20" Silicone Foam (Quanex Premium). Mol. Sieve contained in foam spacer. Hot Melt Butyl (H. B. Fuller HL-5130). Corners bent; final corner sealed with Mylar tape. Low-E glass with edge deletion. December 12, 2012 TEST METHOD: ASTM E SPECIFICATION: ASTM E Initial High Weather High Argon Specimen Frost Fogging Test Humidity Cycling Humidity Concentration Number Point ASTM E Days 63 Days 28 Days ASTM E (OF) (OF) (OF) (OF) Initial I Final 1 <-85 <-85 <-85 <-85 97% / 89% 2 <-85 <-85 <-85 <-85 98% / 90% 3 <-85 <_85 <-85 <-85 98% / 90% 4 <-85 <-85 <-85 <-85 97% / 89% 5 <-85 <-85 <-85 <-85 98% / 90% 6 <-85 <-85 <_85 <-85 96% / 88% 7 8 Average: 9 Passed w/grids 97% / 89% 10 Passed w/grids These results indicate compliance with the ASTM E requirements. )J, ALI Form 992 A HALF OF A CENTURY EXPERIENCE AVAILABLE FOR INDUSTRY

5 Sealed Insulated Glass Test Samples AI least twelve (12) test samples must be submitted. If you offer Low-E then Low-E must be used in the test samples. Ifwithin the NFRC program gas (argon) is offered then the cavity must be gas filled. The glass must be 14" x 20" in overall size. Oversized lest samples will not iii into the test equipment. Glass thickness must be at least 5132" (4mm) but not greater than 114" (6mm), The spacer must be at least 1/4" (6mm) in thickness but not greater than 112" (12mm). Note - Grids should not come within two (2) inches of the overall center of the 14" x 20" as this will make them unable 10 test for frost point. The lest samples should reflect normal product in all other aspects. For triple glazed IG fourteen (14) lest samples must be submitted. The glass must be 5/32" (4mm) and the spacers must be 114" (6mm) so the overall thickness of the units doesn't exceed one (I) inch. Both cavities must be gas filled and the center lite should be Low-E. Prior to shipping test samples. this form must be filled out and sent to A.L.1. (kcn'ii assoc-llihs.cum) for review. Witness/Contact: JOHN SESf;;r4 E-MlliI: vsaa@ V IVTt1A./,4PA-,CCJt!-1 SEALED INSULATED GLASS Cm,[PONENT DESCRIPTION Be specific when describing components. equipment, and process, ) Date of Sampling 12./1;Af;:2 Sample Set #I / ( /2 U!{/ / rs {I" 3/ _JJ:ircll! GLASS: Thickness fa IJ":7 - /lfoll/eyype; Film - Anneal - LOW-E (hard coat '8 Circle /.:") Edge Deletion: - No Film or Low-E Manufacture & Brand.:;S~B=--,foO>..=:O:::... _ DESSICANT: Type (\j,4- Manufacturer & product model # _ Lot Number ~ LOclll;on SEALANT: Type fti3 FL)~ Manufacturer & product model #I Ii L- f)130-/ Z.S J 105"'6:9 " 3000 Lot Number ~ g 65"'3 GAS FILLING: Type orgas!f~goj1...,} Equipment with model # & description of process _ EDIX. - R 5rdJ I E P _oj3e I I-HIA--, /-Se:IJS4L / / To be tested at: 11, L ' I I JJ 1[::X A- :5. ACP-28 {7/()9}

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.095 DH 143.195 DH 145.095 DH 145.195 DH Baseline

More information

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.191 Casement / Awning / Fixed Baseline Product

More information

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.095 SS 145.095 SS Baseline Product for Validation

More information

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.095 SH 145.095 SH 143.095 SH Common Head Baseline

More information

IEA SHC Task 27: Accelerated Aging of IG units: North American Test Methods

IEA SHC Task 27: Accelerated Aging of IG units: North American Test Methods IEA SHC Task 27: Accelerated Aging of IG units: North American Test Methods Hakim Elmahdy, Ph. D., MBA, P. Eng. Institute for Research in Construction National Research Council of Canada Introduction There

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY SERIES/MODEL: 4000 / 4500 DuraGard XT Double Hung Report Number: Original

More information

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: NCTL-110-16086-01 SIMULATION DATE: 08/30/13 REPORT DATE: 08/30/13 Client: Product

More information

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004 Comparison of IG Testing Standard IGMA Summer Meeting August 8, 2004 1 The Task Compare the new Harmonized standards to: Old ASTM stds. Canadian stds. CEN stds. (Europe) ISO std. (proposed) 2 The Standards

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: A6458.01 801 18 Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas PRODUCT TYPE: Fiberglass In Swing Glazed Double Doors SERIES/MODEL:

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: A6839.01 801 18 Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas PRODUCT TYPE: In Swing Fiberglass Double Doors with Speak Easy

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: A6457.01 801 18 Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas PRODUCT TYPE: In Swing Fiberglass Door with Side Lites SERIES/MODEL:

More information

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: NCTL-110-14975-01 SIMULATION DATE: 03/25/13 REPORT DATE: 03/25/13 Client: Product

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS Architectural Testing NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: PARAMOUNT WINDOWS SERIES/MODEL: 6700/ 6750/ 7700/ 8700/ 8750 Report Number: Report Date:

More information

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL TEST REPORT: SERIES 8220 ALUMINUM SINGLE HUNG WINDOW Prepared for: 5625 E. Firestone Boulevard South Gate, CA 90280 1601 Luna Road S-UNITED, INC. Office: (972) 242-0556 Carrollton, Texas 75006 A Quality

More information

QUALITY CONTROL PROCEDURES

QUALITY CONTROL PROCEDURES 11 Dansk Court Toronto, Ontario M9W 5N6 CANADA Tel: 416-674-3831 Fax: 416-674-9323 Toll Free: 1-866-899-6799 www.fenzi-na.com info@fenzi-na.com QUALITY CONTROL PROCEDURES Sealant RATIO CHECK: The sealant

More information

Solarban 70XL and Solarban 70XLVT Coated Glass Technical Considerations and Guidelines

Solarban 70XL and Solarban 70XLVT Coated Glass Technical Considerations and Guidelines General Vitro (formerly PPG Industries) Solarban 70XL and Solarban 70XLVT coated glass are another innovative improvement in energy efficient coated glass technology from Vitro Solarban 70XL low emissivity

More information

Manufacturer s Certification Ply Gem Replacement Windows

Manufacturer s Certification Ply Gem Replacement Windows Manufacturer s Certification Ply Gem Replacement Windows Ply Gem Windows, located at 4415 Pheasant Ridge Road, Suite 300, Roanoke, Virginia 24014, manufactures certain Premium and Pro Series exterior windows

More information

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC. AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT Rendered to: MASTER WINDOW SYSTEMS, INC. SERIES/MODEL: Master 2000 Double Hung Window PRODUCT TYPE: PVC Double Hung Window Summary of Results Title Test Specimen

More information

PENTAGON PROTECTION USA

PENTAGON PROTECTION USA PENTAGON PROTECTION USA Shock Tube Testing for Window Systems March 2009 San Antonio, Texas ABS Consulting Project Number 2127174 ABSG Consulting, Inc. 14607 San Pedro, Suite 215 San Antonio, TX 78232

More information

AAMA/WDMA/CSA 101/I.S.2/A440-08

AAMA/WDMA/CSA 101/I.S.2/A440-08 PERFORMANCE TESTS IN ACCORDANCE WITH AAMA/WDMA/CSA 101/I.S.2/A440-08 Product Manufacturer: Report No.: AI-04016-T1 Rev.1 ACRYLON PLASTICS 122 PAQUIN ROAD WINNIPEG, MANITOBA R2J 3V4 204-669-2345 Report

More information

Meeting ENERGY STAR Version 6.0

Meeting ENERGY STAR Version 6.0 Meeting ENERGY STAR Version 6.0 Presentation Outline What is ENERGY STAR Version 6? Why Change ENERGY STAR? What s New in Version 6 Meeting V6 U Factor & SHGC Requirements Meeting V6 Air Infiltration Requirements

More information

LUXURY SLIDING PATIO & SWINGING FRENCH DOORS

LUXURY SLIDING PATIO & SWINGING FRENCH DOORS M A L I B U LUXURY SLIDING PATIO & SWINGING FRENCH DOORS M A L I B U THE BEAUTY OF YOUR HOME Malibu Sliding Patio and Swinging French Doors enhance the beauty of your home, both inside and out. Each door

More information

AAMA/WDMA/CSA 101/I.S.2/A440-08

AAMA/WDMA/CSA 101/I.S.2/A440-08 PERFORMANCE TESTS IN ACCORDANCE WITH AAMA/WDMA/CSA 101/I.S.2/A440-08 Product Manufacturer: Report No.: AI-04016-U1 Rev.1 ACRYLON PLASTICS 122 PAQUIN ROAD WINNIPEG, MANITOBA R2J 3V4 204-669-2345 Report

More information

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES LOW PROFILE FIXED. Dominion Doors & Windows Ltd.

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES LOW PROFILE FIXED. Dominion Doors & Windows Ltd. COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES LOW PROFILE FIXED FOR Dominion Doors & Windows Ltd. IN ACCORDANCE WITH: CAN/CSA A440.2-14 Report to: Dominion Doors

More information

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent Architectural Testing PERFORMANCE TEST REPORT Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent This report contains in its entirety: Cover Page: 1 page Report Body: 6 pages

More information

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 * SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 * PRODUCT: Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC. FRC U-FACTOR, SHGC, VT, & CODESATIO RESISTACE COMPUTER SIMULATIO REPORT Rendered to: CR LAURECE CO., IC. SERIES/MODEL: StormWall XL Curtain Wall Report umber: Report Date: 10/14/16 FRC U-FACTOR, SHGC,

More information

Lifestyle Series Casement

Lifestyle Series Casement Product Selection Guide Size and Performance Data...LS-CM-2 Features and Options...LS-CM-3 Combination Assemblies...LS-CM-4 Glazing Performance Dual-Pane...LS-CM-8 Triple-Pane... LS-CM-10 Grille Types

More information

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES CASEMENT WINDOW. Dominion Doors & Windows Ltd.

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES CASEMENT WINDOW. Dominion Doors & Windows Ltd. COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES CASEMENT WINDOW FOR Dominion Doors & Windows Ltd. IN ACCORDANCE WITH: CAN/CSA A440.2-14 Report to: Dominion Doors

More information

AAMA THERMAL PERFORMANCE REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC.

AAMA THERMAL PERFORMANCE REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC. Archi t ectural Testing THERMAL PERFORMANCE REPORT Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC. SERIES/MODEL: S80 Bi-Fold Door (1" Dual Glazed) TYPE: Swinging Door - Double Report No:

More information

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina TEST REPORT Report No.: G4212.01-109-44 Rendered to: VELUX America LLC Greenwood, South Carolina PRODUCT TYPE: Skylight with Curb SERIES/MODEL: Specials Dome Skylight 0.118 thickness PC smooth/0.118 thickness

More information

1201 North Catalina Ave. #818 Redondo Beach, CA (310) FAX (866) Classification of Air Cleanliness

1201 North Catalina Ave. #818 Redondo Beach, CA (310) FAX (866) Classification of Air Cleanliness C E 1201 North Catalina Ave. #818 Redondo Beach, CA 90277 (310) 372-5011 FAX (866) 882-7457 John@ceccertify.com Classification of Air Cleanliness Company Test Specification Date of Certification Corona,

More information

AAMA THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM

AAMA THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM AAMA 507-07 THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM SERIES/MODEL: 7600 Projected Vent TYPE: Projecting (Awning - Single) Report No: Original Report Date: Revised Report

More information

Specifications... Quick Spec Guide...

Specifications... Quick Spec Guide... TABLE OF CONTENTS Specifications........................................... Quick Spec Guide....................................... Elevations/Sizes: 1/4" Scale Full Awning Units..................................

More information

Pella Impervia 350 Series Vinyl Awning Windows and Sliding Patio Doors

Pella Impervia 350 Series Vinyl Awning Windows and Sliding Patio Doors Pella Impervia 350 Series Vinyl Awning Windows and Sliding Patio Doors Pella 350 Series premium vinyl windows and patio doors are available in a variety of frame types to help ensure a smooth installation

More information

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description ncompass by Pella SCTION DIRCTORY SINGL-HUNG Size and performance summary Glazing performance Grille profiles and patterns Size tables Design Data Detailed Product Description Cross sections The information

More information

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2 FRAME SINGLE SLIDER LIFT OUT PERFORMANCE EVALUATION OF SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT For Dominion Doors & Windows Ltd. IN ACCORDANCE WITH: AAMA/WDMA/CSA 101/I.S.2/A440-11 AND A440S1-17 Report

More information

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION SAMPLE ORDINANCE 3/5/2012 Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION Section 1: Applicable Service Territory Net metering and electrical system interconnection is available on a first-come,

More information

BS EN ISO :2006

BS EN ISO :2006 Exova (UK) Ltd Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com BS EN ISO 10077-1:2006 Calculation

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information

Section 4 DMS-9203, Asphaltic Concrete Patching Material (Containerized)

Section 4 DMS-9203, Asphaltic Concrete Patching Material (Containerized) Section 4 DMS-9203, Asphaltic Concrete Patching Overview Effective Date: August 2004 - December 2005. This Specification governs for rapid curing containerized asphaltic concrete mixture intended primarily

More information

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website 3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio 43219 Toll Free 800-746-6686 Website www.simonton.com E-Mail archdetails@simonton.com Product Guide Specification Specifier Notes: This product guide

More information

Guide Specification SECTION VINYL WINDOWS

Guide Specification SECTION VINYL WINDOWS February 2018 3948 Townsfair Way, Suite 200 Columbus, Ohio 43219 Toll Free 800-746-6686 Website www.simonton.com Email archdetails@simonton.com Guide Specification Specifier Notes: This guide specification

More information

DF COLLECTION. Architectural Detail Guide Hybrid Awning Window DF 3113 TABLE OF CONTENTS

DF COLLECTION. Architectural Detail Guide Hybrid Awning Window DF 3113 TABLE OF CONTENTS TABLE OF CONTENTS Specifications... 1-2 Quick Spec Guide... 1-3 Clear Opening and Daylight Specifications... 1-5 General Information Multiple Assemblies... 1-6 Handing and Operation... 1-7 Elevation Drawing

More information

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description SCTIN DIRCTRY Size and performance summary Glazing performance Grille profiles and patterns Size tables Design Data Detailed Product Description Cross sections The information published in this document

More information

MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT

MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1712 FEBRUARY 1991 MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT 1712.01 SCOPE 1712.02 REFERENCES 1712.03 DEFINITIONS 1712.05 MATERIALS

More information

SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK

SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK Е70 WINDOW AND DOOR SYSTEM WITH THERMAL BREAK TABLE OF CONTENTS GENERAL INFORMATION page 9 BUILDING PHYSICS page 17 TABLES page 25 PROFILES page 31

More information

CONSTRUCTION & DEMOLITION (C&D) RECYCLING APPLICATION COMMERCIAL RECYCLING SERVICE PROVIDER

CONSTRUCTION & DEMOLITION (C&D) RECYCLING APPLICATION COMMERCIAL RECYCLING SERVICE PROVIDER CONSTRUCTION & DEMOLITION (C&D) RECYCLING APPLICATION COMMERCIAL RECYCLING SERVICE PROVIDER The Construction & Demolition Recycling Permit allows removal of recyclable materials from construction sites

More information

Sliding Patio Doors Flat Casing Vinyl

Sliding Patio Doors Flat Casing Vinyl TABLE OF CONTENTS Specifications... 5-2 QuickSpecGuide... 5-3 Elevations/Sizes: 1/4 Scale 2-PanelSlidingPatioDoors... 5-4 2-PanelSlidingPatioDoorswithTransoms... 5-5 Transoms... 5-7 Sidelights... 5-9 SectionDetails...

More information

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TORO ALUMINUM. SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TORO ALUMINUM. SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning Architectural Testing AAMA 507-12 THERMAL PERFORMANCE REPORT Rendered to: TORO ALUMINUM SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning Report No: Report Date: 130 Derry Court

More information

Physical Properties of Window Films

Physical Properties of Window Films Physical Properties of Window Films Name 3M Renewable Energy Date: July 3, 20104 Attn: Paul Neumann Revision Date: September 18, 2014 Address: 3M Center, 235-3D-02 Author: William Stegeman City, State,

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: EARTHWISE GROUP, L.L.C

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: EARTHWISE GROUP, L.L.C NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT (Revised) Rendered to: EARTHWISE GROUP, L.L.C SERIES/MODEL: 623.620 Patio Door Report Number: Original Report Date: Revised

More information

AAMA THERMAL PERFORMANCE REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System

AAMA THERMAL PERFORMANCE REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System AAMA 507-07 THERMAL PERFORMANCE REPORT Rendered to: UNITED STATES ALUMINUM SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System Report No: Report Date: 08/22/08 130 Derry Court York, PA 17406-8405

More information

General Information SECTION DIRECTORY

General Information SECTION DIRECTORY SECTION DIRECTORY General Information Product Summary... V-AW-2 Product Selection Guide... V-AW-3 Size and Performance Data... V-AW-3 Features and Options... V-AW-3 Sound Transmission Class and Outdoor-Indoor

More information

Double Hung. Power Lift 28,000 Constant Force

Double Hung. Power Lift 28,000 Constant Force Insul-Tec Double Hung Stylish Full 3¼ Depth Welded Mainframe with beveled colonial exterior curves that are not only beautiful, but also allow for maximum weld surface resulting in outstanding strength

More information

WELLINGTON, NEW ZEALAND. PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998

WELLINGTON, NEW ZEALAND. PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998 WELLINGTON, NEW ZEALAND PURSUANT to sections 152, 155(a) and (e) and 158(a)(i) of the Land Transport Act 1998 I, Gerry Brownlee, Minister of Transport, HEREBY make the following ordinary Rule: Land Transport

More information

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * PRODUCT: Heavy Duty Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

SECTION 916 (Pages ) is deleted and the following substituted: SECTION 916 BITUMINOUS MATERIALS

SECTION 916 (Pages ) is deleted and the following substituted: SECTION 916 BITUMINOUS MATERIALS 916 BITUMINOUS MATERIALS. (REV 7-28-03) (FA 1-13-04) (7-04) SECTION 916 (Pages 785-797) is deleted and the following substituted: SECTION 916 BITUMINOUS MATERIALS 916-1 Superpave PG Asphalt Binder: 916-1.1

More information

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 * SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 * PRODUCT: Driver Suits 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating and

More information

Submittal Requirements for Product Evaluation - Doors

Submittal Requirements for Product Evaluation - Doors TEXAS DEPARTMENT OF INSURANCE Engineering Services / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 Submittal Requirements for Product

More information

8400 SERIES THERMAL PERFORMANCE CHART

8400 SERIES THERMAL PERFORMANCE CHART Page 1 of 5 Pages LE-CL WCW-M-30-00386-00001 0.32 3.13 0.23 0.45 WCW-M-30-00386-00002 0.32 3.13 0.21 0.40 DS-LAMI (PVB030) LE-CL (Lami) WCW-M-30-00388-00001 0.32 3.13 0.23 0.44 WCW-M-30-00388-00002 0.32

More information

ThermaSeal TM220 SECTIONAL OVERHEAD DOORS

ThermaSeal TM220 SECTIONAL OVERHEAD DOORS ThermaSeal TM220 SECTIONAL OVERHEAD DOORS ** NOTE TO SPECIFIER ** Raynor; commercial sectional overhead doors. This section is based on the products of Raynor, which is located at: 1101 East River Rd.

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS INTERIM PRESIDENT E. FELICIA BRANNON JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

Geometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress.

Geometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress. Geometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress. George Fofeldea Power Engineer, 3M Canada August 2018 Abstract 3M invented cold shrink

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION Architectural Testing NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: PARAMOUNT WINDOWS CORPORATION SERIES/MODEL: ECO-View 6100/7100 Report Number: B6000.01-301-45

More information

SERVICE LETTER SERIAL NUMBERS. 550/ thru -0505, thru -0733, thru -0969

SERVICE LETTER SERIAL NUMBERS. 550/ thru -0505, thru -0733, thru -0969 TITLE FUSELAGE - DORSAL FIN VANE INSPECTION EFFECTIVITY MODEL SERIAL NUMBERS 550/551-0002 thru -0505, -0550 thru -0733, -0801 thru -0969 REASON The equivalent of this service letter has been incorporated

More information

FAA approval has been obtained on technical data in this publication that affects airplane type design.

FAA approval has been obtained on technical data in this publication that affects airplane type design. Caravan Service Bulletin July 20, 2010 TITLE RIGHT INBOARD FLAP BELL CRANK BEARING INSPECTION / REPLACEMENT EFFECTIVITY The airplanes that follow that have had part number S3952-5 Bearing(s) installed

More information

Strong windows. stronger value.

Strong windows. stronger value. C G I i m pa c t r e s i s ta n t windows & doors Strong windows. stronger value. Now you can. 0127-0009-sparta-launch-brochure-mo2.indd 1 7/1/2018 11:12:53 PM CGIwindows.com NOW YOU CAN. Strong in construction.

More information

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS SECTION DIRECTORY SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS The information published in this document

More information

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS SECTIN DIRECTRY SIZE AND PERFRMANCE SUMMARY GLAZING PERFRMANCE GRILLE PRFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRDUCT DESCRIPTIN CRSS SECTINS The information published in this document is

More information

Canadian Association of Rocketry Rocket Motor Certification

Canadian Association of Rocketry Rocket Motor Certification Rocket Motor Certification January 7th, 2010 Session Submitted to the CAR Executive January 19 th, 2010 2 Introduction A motor testing session was held at the facility in on January 7 th, 2010. Winter

More information

Architect Series Traditional

Architect Series Traditional SECTION DIRECTORY Product Selection Guide Size and Performance Data... OSBF-2 Glazing Performance... OSBF-3 Grille Types... OSBF-7 Design Data Vent... OSBF-11 Detailed Product Descriptions... OSBF-14 Unit

More information

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description SECTIN DIRECTRY Size and performance summary Glazing performance Grille profiles and patterns Size tables Design Data Detailed Product Description Cross sections The information published in this document

More information

Product Guide Specification

Product Guide Specification July 2013 3948 Townsfair Way, Suite 200 Columbus, Ohio 43219 Toll Free 800-746-6686 Website www.simonton.com E-Mail archdetails@simonton.com Product Guide Specification Specifier Notes: This product guide

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

HURRICANESHIELD IMPACT-RESISTANT GLASS SECTION DIRECTORY. Size and performance summary. Glazing performance. Grille profiles and patterns.

HURRICANESHIELD IMPACT-RESISTANT GLASS SECTION DIRECTORY. Size and performance summary. Glazing performance. Grille profiles and patterns. SECTIN DIRECTRY Size and performance summary Glazing performance Grille profiles and patterns Size tables Design Data Detailed Product Description Cross sections The information published in this document

More information

ALUMINUM. Yellow Dog Window. Windows & Doors. Visit our website at

ALUMINUM. Yellow Dog Window. Windows & Doors. Visit our website at ALUMINUM Windows & Doors Yellow Dog Window Visit our website at www.ydwindowinc.com A Tradition of Quality WE RE THE CALM BEFORE - AND AFTER - THE STORM It s unpredictable. It s inconvenient. And yes,

More information

GOLD LABEL CERTIFICATION

GOLD LABEL CERTIFICATION 2 Great Windows You Can See The Difference! Full Head Bevel Drip Cap These days, with so many choices, deciding on a window can be challenging. So we ve made it easy for you! We feature two extremely energy

More information

We are a reputed importer and distributor of a wide range of Pressure Sensitive Adhesive Tapes, Sealants & Adhesives and PU Foams. These products are

We are a reputed importer and distributor of a wide range of Pressure Sensitive Adhesive Tapes, Sealants & Adhesives and PU Foams. These products are We are a reputed importer and distributor of a wide range of Pressure Sensitive Adhesive Tapes, Sealants & Adhesives and PU Foams. These products are easy to use, resist humidity, possess high strength

More information

Casement Windows Builders Clad-Wood

Casement Windows Builders Clad-Wood TABL OF CONTNTS Specifications... 1-2 QuickSpecGuide... 1-3 levations: 1/4 Scale Casement... 1-4 CasementPicture... 1-13 CasementTransom... 1-15 CasementRadius... 1-18 Grille Patterns... 1-20 ClearOpeningandDaylightSpecifications...

More information

SL20C SL22C. ScreenLine. Technical Catalogue. english. double-glazed unit 20 mm 22 mm

SL20C SL22C. ScreenLine. Technical Catalogue. english. double-glazed unit 20 mm 22 mm VENETIAN SL20C SL22C BLIND english Technical Catalogue double-glazed unit 20 mm 22 mm dimensions technical specification SL20C SL22C System C C SL20C VENETIAN SL22C BLIND The venetian blinds SL20C / SL22C

More information

Product Selection Guide Size and Performance Data...W-HG-2 Features and Options...W-HG-3 Combination Assemblies...W-HG-4 Glazing Performance...

Product Selection Guide Size and Performance Data...W-HG-2 Features and Options...W-HG-3 Combination Assemblies...W-HG-4 Glazing Performance... SECTION DIRECTORY Product Selection Guide Size and Performance Data...W-HG-2 Features and Options...W-HG-3 Combination Assemblies...W-HG-4 Glazing Performance...W-HG-6 Grille Types Grille Profiles...W-HG-10

More information

Enhance the value & style of your home

Enhance the value & style of your home by As with all Monte Verde products, Bay View includes premium craftsmanship, beauty and features at a value price. Enhance the value & style of your home More Glass. More View. More Light. The low-profile

More information

SUBJECT: ELECTRICAL POWER SYSTEM UNIT AND ROTORCRAFT FLIGHT MANUAL TEMPORARY REVISION, CANCELLATION OF

SUBJECT: ELECTRICAL POWER SYSTEM UNIT AND ROTORCRAFT FLIGHT MANUAL TEMPORARY REVISION, CANCELLATION OF MODEL AFFECTED: 505 ALERT SERVICE BULLETIN 505-17-03 PSL 7000000247 28 November 2017 Revision A, 14 February 2018 Revision B, 6 March 2018 Revision C, 18 September 2018 SUBJECT: ELECTRICAL POWER SYSTEM

More information

STRONG WINDOWS. STRONGER VALUE.

STRONG WINDOWS. STRONGER VALUE. CGI IMPACT RESISTANT INDOS & DOORS STRONG INDOS. STRONGER VALUE. NO YOU CAN. CGIwindows.com NO YOU CAN. STRONG IN CONSTRUCTION. Built for heavy impact. STRONG IN AFFORDABILITY. A smart price for an exceptional

More information

Over Sixty Years of Quality

Over Sixty Years of Quality Over Sixty Years of Quality The Coeur d Alene Window Company is a division of McVay Brothers (f.1955), one of the oldest and most respected home improvement companies in America. Our Team - Experienced

More information

TERMS AND CONDITIONS

TERMS AND CONDITIONS XXV. NET METERING A. Applicability and Availability 1. The terms Net Metering Service, Demand Charge-based Time-of- Use Tariff, Net Metering Customer, Customer, Time-of-Use Customer, Time-of-Use Tier,

More information

PASS. Vincent Chow Wai Kit Manager, Chemical Laboratory

PASS. Vincent Chow Wai Kit Manager, Chemical Laboratory Recipient Email: DawnG@greaterchina-usa.com Pages: Page 1 of 6 SAMPLE INFORMATION: Description: Custom Stress Ball Assortment: - Purchase Order Number: 11866JD SKU/style No.: - Toy Co./Agency: - Factory

More information

MACHINERY & EQUIPMENT FOR THE FENESTRATION INDUSTRY. Specializing in...

MACHINERY & EQUIPMENT FOR THE FENESTRATION INDUSTRY. Specializing in... QUICK REFERENCE PRODUCT GUIDE MACHINERY & EQUIPMENT FOR THE FENESTRATION INDUSTRY Horizontal & Vertical Stretch Wrappers Custom Window Dollies Custom Glass Dollies Insulated Glass Dollies Glass Cutting

More information

Faulted Circuit Interrupting Tests on Type CMU Power Fuses

Faulted Circuit Interrupting Tests on Type CMU Power Fuses CP No.: CP0509 Rev.01 Page: 1 of 9 CERTIFIED TEST REPORT Faulted Circuit Interrupting Tests on Type CMU Power Fuses REV. 01 DATE: August 10, 2005 ORIGINAL REPORT DATE: May 25, 2005 Cooper Power Systems,

More information

Warranty, Parts & Install Info 1. Series 4600 Double Hung Windows 2. Series 4710 Casement Windows 3. Series 9000 Sliding Patio Door 4

Warranty, Parts & Install Info 1. Series 4600 Double Hung Windows 2. Series 4710 Casement Windows 3. Series 9000 Sliding Patio Door 4 Warranty, Parts & Install Info 1 Series 4600 Double Hung Windows 2 Series 4710 Casement Windows 3 Series 9000 Sliding Patio Door 4 Series 9200 Inswing Doors 5 Series 9300 Outswing Doors 6 Series 9380 Outswing

More information

Schüco SkyLine S 65. Glazing beads and cover caps. Glazing beads. Cover caps. Glazing, gaskets and. Art. No. pol. total. Art. No. pol.

Schüco SkyLine S 65. Glazing beads and cover caps. Glazing beads. Cover caps. Glazing, gaskets and. Art. No. pol. total. Art. No. pol. Glazing beads and cover caps Glazing beads Circumf. (mm) pol. total 336 410 57 149 Circumf. (mm) pol. total 336 420 106 208 Circumf. (mm) Cover caps pol. total 336 430 79 167 Circumf. (mm) pol. total 336

More information

Product Guide Specification

Product Guide Specification October 2011 3948 Townsfair Way, Suite 200 Columbus, Ohio 43219 Toll Free 800-746-6686 Website www.simonton.com E-Mail archdetails@simonton.com Product Guide Specification Specifier Notes: This product

More information

Single-Hung Windows Premium Atlantic Vinyl

Single-Hung Windows Premium Atlantic Vinyl TABL OF CONTNTS Specifications... 3-2 QuickSpecGuide... 3-3 levations/sizes: 1/4 Scale Single-Hung... 3-4 ImpactSingle-Hung... 3-10 GlazingOptions: Scale... 3-11 Grille Patterns... 3-12 SectionDetails:

More information

This Service Bulletin is applicable only to airplanes equipped with placards that are written in English.

This Service Bulletin is applicable only to airplanes equipped with placards that are written in English. Caravan Service Bulletin June 25, 2007 TITLE FUEL CAPACITY PLACARD REPLACEMENT EFFECTIVITY This Service Bulletin is applicable only to airplanes equipped with placards that are written in English. The

More information

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL THE CONTENT OF THIS DOCUMENT IS THE PROPERTY OF ALENIA AERONAUTICA S.p.A. THIS DOCUMENT IS SUPPLIED IN CONFIDENCE AND COMMERCIAL

More information

ALUMINUM HORIZONTAL ROLLER WINDOW

ALUMINUM HORIZONTAL ROLLER WINDOW ALUMINUM HORIZONTAL ROLLER WINDOW Series HR610 Monolithic glazing does not provide hurricane protection. Specifications: Window members are extruded from a minimum of 6063-T5 aluminum alloy Frame members

More information

Faulted Circuit Interrupting Tests on Type CMU Power Fuses

Faulted Circuit Interrupting Tests on Type CMU Power Fuses CP No.: CP0508 Rev. 01 Page: 1 of 9 CERTIFIED TEST REPORT Faulted Circuit Interrupting Tests on Type CMU Power Fuses REV. 01 DATE: August 10, 2005 ORIGINAL REPORT DATE: May 25, 2005 Cooper Power Systems,

More information

Primed Epicr Radius and Geometric Windows - In-Sash Custom Wood

Primed Epicr Radius and Geometric Windows - In-Sash Custom Wood TABLE OF CONTENTS Specifications... 20-2 QuickSpecGuide... 20-4 Elevations/Sizes:1/4 Scale... 20-6 Casement Half Round Units... 20-8 Casement Quarter Round Units... 20-9 Double-Hung Half Round Units...

More information