MANHOLE INDEX INDEX CONCRETE MANHOLE SPECIFICATIONS ASTM SPECIFICATIONS

Size: px
Start display at page:

Download "MANHOLE INDEX INDEX CONCRETE MANHOLE SPECIFICATIONS ASTM SPECIFICATIONS"

Transcription

1 MANHOLE INDEX INDEX M1...STANDARD STORM MANHOLE ASSEMBLY A1 M2...STANDARD MANHOLE ASSEMBLY A2 M3...CONICAL MANHOLE ASSEMBLY A3 M4...CONICAL MANHOLE ASSEMBLY A4 M5...CONICAL MANHOLE ASSEMBLY A5 M6...CONICAL MANHOLE ASSEMBLY A6 M7...DOUBLE CONICAL MANHOLE ASSEMBLY A7 M8...REDUCING SLAB ASSEMBLY A8 M9...STANDARD TYPE 5 CATCHBASIN M10...STANDARD TYPE 6 CATCHBASIN M11...STANDARD SQUARE CATCHBASIN M12...STANDARD SLUICE BOX M13...VALVE CHAMBER ASSEMBLY M14...STANDARD SEWAGE LIFT STATION M15...APPLICATIONS FOR LARGE DIAMETER UNITS M16...STANDARD INTERNAL DROP SECTIONS M17...STANDARD BASE SECTIONS M18...STANDARD INTERMEDIATE SECTIONS M19...STANDARD ECCENTRIC CONES M20...STANDARD COVERS M21...CATCHBASIN COVERS M22...STANDARD REDUCING SLABS M23...STANDARD GRADE RINGS M24...MANHOLE TEE BASE M25...MANHOLE TEE BASE BEND M26...MANHOLE BENCHING WITH GASKETS M27...MAXIMUM PIPE SIZES FOR MANHOLES M28...SINGLE OFFSET JOINT DETAIL M29...STANDARD MANHOLE JOINT SEALS CONCRETE MANHOLE SPECIFICATIONS CSA SPECIFICATIONS CSA A257.3 Joints for Circular Concrete Sewer, Manholes and Culvert Pipe Using Rubber Gaskets CSA A257.4 Precast Reinforced Concrete Manhole Sections ASTM SPECIFICATIONS C478 Precast Reinforced Concrete Manhole Sections C497 Standard Methods of testing Concrete Pipe, Manhole Sections or Tile C923 Resilient Connections Between Reinforced Concrete Manhole Structures and Pipes C443 Joints for Circular Concrete Sewer and Culvert Pipe Using Rubber Gaskets C990 Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants

2 STANDARD STORM MANHOLE ASSEMBLY A to 3600 mm DIAMETER 42 to 144 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Offset or Center Hole As Required) See chart page M20 INTERMEDIATE SECTION FLAT BASE See chart page M17 SUMP AS REQUIRED M1

3 STANDARD MANHOLE ASSEMBLY A to 3600 mm DIAMETER 42 to 144 in. DIAMETER CAST IRON FRAME AND GRATE. GRADE RING See chart page M23 COVER (Offset or Center Hole As Required) See chart page M20 INTERMEDIATE SECTION BENCHED BASE See chart page M17 NOTE: FOR LIFTING PURPOSES mm/120" and 3600mm/144" bases should be benched on site due to excessive weight of the bases. M2

4 CONICAL MANHOLE ASSEMBLY A Reduced to 1050 mm DIAMETER 48 Reduced to 42 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Center Hole As Required) See chart page M20 INTERMEDIATE SECTION mm/42 in. Available in mm/12 in. laid height increments ECCENTRIC CONE - EC1 610mm/24 in. Laid height See chart page M19 INTERMEDIATE SECTION mm/48 in. Available in mm/12 in. laid height increments BENCHED BASE mm/48 in. Available in mm/12 in. laid height increments See chart page M17 M3

5 CONICAL MANHOLE ASSEMBLY A Reduced to 750 mm DIAMETER 48 reduced to 30 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Center Hole As Required) See chart page M20 INTERMEDIATE SECTION - 750mm/30 in. mm/12 in. laid height ECCENTRIC CONE - EC2 1219mm/48 in. laid height See chart page M19 INTERMEDIATE SECTION mm/48 in. Available in mm/12 in. laid height increments BENCHED BASE mm/48 in. Available in mm/12 in. laid height increments See chart page M17 Other section heights not recommended M4

6 CONICAL MANHOLE ASSEMBLY A Reduced to 750 mm DIAMETER 42 reduced to 30 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Center Hole As Required) See chart page M20 INTERMEDIATE SECTION - 750mm/30 in. mm/12 in. laid height ECCENTRIC CONE - EC3 915mm/36 in. laid height See chart page M19 INTERMEDIATE SECTION mm/42 in. Available in mm/12 in. laid height increments BENCHED BASE mm/42 in. Available in mm/12 in. laid height increments See chart page M17 Other section heights not recommended M5

7 CONICAL MANHOLE ASSEMBLY A Reduced to 600 mm DIAMETER 42 reduced to 24 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Center Hole As Required) See chart page M20 INTERMEDIATE SECTION - 600mm/24 in. mm/12 in. laid height ECCENTRIC CONE - EC4 1219mm/48 in. laid height See chart page M19 INTERMEDIATE SECTION mm/42 in. Available in mm/12 in. laid height increments BENCHED BASE mm/42 in. Available in mm/12 in. laid height increments See chart page M17 Other section heights not recommended M6

8 CONICAL MANHOLE ASSEMBLY A7 1200/48 Reduced to 750 mm / 30 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Center Hole As Required) See chart page M20 INTERMEDIATE SECTION - 750mm/30 in. mm/12 in. laid height ECCENTRIC CONE - EC3 915mm/36 in. laid height See chart page M19 INTERMEDIATE SECTION mm/42 in. Available in mm/12 in. laid height increments ECCENTRIC CONE - EC1 610mm/24 in. laid height See chart page M19 BENCHED BASE mm/48 in. Available in mm/12 in. laid height increments See chart page M17 Other section heights not recommended M7

9 REDUCING SLAB ASSEMBLY A8 750 to 3600 mm DIAMETER 30 to 144 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Offset or Center Hole As Required) See chart page M20 INTERMEDIATE SECTION REDUCING SLAB See chart page M22 INTERMEDIATE SECTION FLAT or BENCHED BASE See chart page M17 M8

10 STANDARD TYPE 5 CATCHBASIN 750 mm DIAMETER 30 in DIAMETER CAST IRON FRAME AND GRATE. GRADE RING See chart page M23 COVER (Center Hole As Required) See chart page M20 INTERMEDIATE SECTION - 750mm/30 in. /12, 1219/48 and 1524mm/60 in. laid heights BASE - 750mm/30 in. 1524mm/60 in. laid height See chart page M17 SUMP AS REQUIRED 118mm (4 5/8 in.) BASE (Metric / Imperial) BASE DIAMETER 750/30 FLAT BASE HEIGHT 1219/48 MASS/WEIGHT kg/lbs. 1214/ / / /3220 M9

11 STANDARD TYPE 6 CATCHBASIN 1050 to 3600 mm DIAMETER 42 to 144 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER (Offset or Center Hole/Square Opening As Required) See chart page M20 / M21 INTERMEDIATE SECTION FLAT BASE See chart page M17 SUMP AS REQUIRED M10

12 STANDARD SQUARE CATCHBASIN 600 mm Square 24 in. Square 610mm 24 in. 610mm 24 in. TOP VIEW Cast iron frame and grate. 864mm 34 in. 610mm 24 in. 127mm 5 in. 610mm 24 in. 127mm 5 in. 432mm 17 in. 1727mm 68 in. 457mm 18 in. or as required 762mm 30 in. SQUARE CATCHBASIN (Metric / Imperial) CATCHBASIN DIAMETER CATCHBASIN MASS/WEIGHT HEIGHT kg/lbs. 600x600/24x24 600x600/24x / / / /2825 M11

13 STANDARD SLUICE BOX 750 mm Square 30 in. Square 254mm 762/30 10 in. 250mm/10 in. DIAMETER OPENING STANDARD 762/30 254mm 10 in. TOP VIEW Cast iron frame and grate. GROUT AS REQUIRED 152mm 6 in. 610mm 24 in. 457mm 18 in. 152mm 6 in. 457mm 18 in. 152mm 6 in. 762mm 30 in. SLUICE BOX (Metric / Imperial) SLUICE BOX DIAMETER FLAT BASE HEIGHT MASS/WEIGHT kg/lbs. MASS/WEIGHT C/W FRAME AND GRATE kg/lbs. 450x450/18x18 610/24 635/ /1215 M12

14 VALVE CHAMBER ASSEMBLY 1050, 1200 and 1500 mm DIAMETER 42, 48 and 60 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING See chart page M23 COVER See chart page M20 INTERMEDIATE SECTION BASE See chart page M17 OPTIONAL 406mm 16 in. VALVES BY OTHERS 508mm 20 in. 1524mm 60 in. OPTIONAL BASE PADS 406mm 16 in. 203mm 8 in. TOP VIEW OF BASE PADS M13

15 STANDARD SEWAGE LIFT STATION 1200 to 3600 mm DIAMETER 48 to 144 in. DIAMETER VARIES ACCESS FRAME AND COVER (optional) COVER See page M20 CAST-IN GASKET INTERMEDIATE SECTION FLAT BASE See chart page M17 CONCRETE GROUT (SLOPED AS REQUIRED) NOTE: Mechanical and Electrical equipment to be supplied by others. M14

16 APPLICATIONS FOR LARGE DIAMETER UNITS 3000 to 3600 mm DIAMETER 120 to 144 in. DIAMETER FLAT COVER FLAT COVER HALF SECTION Inlet STANDARD STORMCEPTOR Outlet SECTION REDUCING COVER SECTION LIFT STATIONS OPTIONAL MONOBASE SECTION STORMCEPTORS STANDARD FLAT BASE MECHANICAL SERVICES HALF SECTION SECTION SECTION FLAT BASE TUNNELS CONTAINMENT CHAMBER M15

17 STANDARD INTERNAL DROP SECTIONS 1200 and 1500 mm DIAMETER 48 and 60 in. DIAMETER TYPICAL PLAN VIEW 203 to 533 8" to 21" Standard pipe diameter Standard diameter Standard wall thickness Standard laid height 150mm (6") Min. 51mm (2") FLOW Standard pipe diameter Standard wall thickness INTERMEDIATE INTERNAL TOP DROP SECTION Standard diameter Standard laid height 51mm (2") or 381mm (12" or 15") Standard wall thickness INTERMEDIATE INTERNAL DROP SECTION NOTE: Custom sizes available upon request M16

18 M17 THICKNESS WALL HEIGHT FLAT BASE MASS/WEIGHT kg/lbs. HEIGHT LAID THICKNESS BASE SLAB MASS/WEIGHT BASES MANHOLE DIAMETER BASE HEIGHT BENCHED kg/lbs. / /5 178/7 152/6 1219/48 915/36 610/24 /12 915/36 610/ / /48 / / /48 610/24 915/36 /12 915/ / /60 610/ /72 / / / / / / / / / / / / / / / / / / / / / /8 203/8 152/6 152/6 229/9 203/8 298/ / /48 /12 610/24 915/ / /48 915/36 610/24 / / /96 610/ /48 915/36 /12 / /48 915/36 610/ / / / / / / / / / / / / / / / / / / / / / / /96 203/8 203/8 /12 / / / / / / / / / / / / / / / / / / / /72 457/18 610/24 915/ /48 610/24 915/ / / / / / / /48 915/36 610/ / / / / / / / / / / / / / / / / / / / /72 - (metric/imperial) STANDARD BASE SECTIONS 1050 to 3600 mm DIAMETER 42 to 144 in. DIAMETER

19 STANDARD INTERMEDIATE SECTIONS 600 to 3600 mm DIAMETER 24 to 144 in. DIAMETER LAID HEIGHT INTERMEDIATE SECTIONS (Metric) mm SECTION DIAMETER HEIGHTS MASS WALL kg/m THICKNESS SIZES AVAILABLE INTERMEDIATE SECTIONS (Imperial) in. SECTION DIAMETER HEIGHTS WEIGHT lbs./foot WALL THICKNESS SIZES AVAILABLE M18

20 STANDARD ECCENTRIC CONES LAID HEIGHT WALL ECCENTRIC CONES CONE TYPE CONE DIAMETER (Metric) mm LAID HT. MASS kg WALL THICKNESS EC to EC to EC to to EC to ECCENTRIC CONES (Imperial) in. CONE TYPE CONE DIAMETER LAID HT. WEIGHT lbs. WALL THICKNESS EC1 48 to EC2 48 to EC3 42 to to EC4 42 to M19

21 STANDARD COVERS 600 to 3600 mm DIAMETER 24 to 144 in. DIAMETER TOP VIEW OPENING DIAMETER AS REQUIRED STANDARD OPENINGS: 600mm/24 in. 675mm/27 in. 750mm/30 in. RECESS OPTIONAL OPENING DIAMETER AS REQUIRED LAID HEIGHT OFFSET OPENING Cover thickness CENTERED OPENING STANDARD ACCESS HOLE PATTERNS AS SHOWN ABOVE. OTHER LOCATIONS FOR HOLES AVAILABLE BY REQUEST. NOTES: COVERS COVER DIAMETER 600/24 242/ /24 300/12 750/30 242/ /30 300/ / /42 267/ / / /48 267/ / / / /84 324/ /13 330/ /96 330/ / /144 Special sizes upon request (Metric / Imperial) LAID HEIGHT 457/18 457/18 COVER THICKNESS 152/6 152/6 152/6 190/ /3 152/6 616/ / / /8 203/8 203/8 203/8 MASS/WEIGHT kg/lbs. 113/ / / / / / / / / / /7720 / /18345 / /25545 The weights provided are calculated using a 600mm diameter opening. M20

22 CATCH BASIN COVERS 1050 to 1800 mm DIAMETER 42 to 72 in. DIAMETER TOP VIEW TWIN 600mm/24" SQUARE OPENING 600mm/24" SQUARE OPENING Cover thickness OFFSET OPENING Laid height Cover thickness CENTERED OPENING Laid height COVERS NUMBER OF OPENINGS (Metric / Imperial) COVER DIAMETER 1050/ / / / / / / / /42 LAID HEIGHT 267/ / / /13 267/ / / /13 572/22.5 COVER THICKNESS 152/6 152/6 203/8 203/8 152/6 152/6 203/8 203/8 457/18 The weights provided are calculated using a 600mm square opening. Cover thickness MASS/WEIGHT kg/lbs. 589/ / / / / / / /4254 3/2520 CENTERED OPENING Standard access hole patterns as shown above. Other locations for holes available by request. Laid height NOTES: Special sizes upon request M21

23 STANDARD REDUCING SLABS 750 to 3600 mm DIAMETER 30 to 144 in. DIAMETER LAID HEIGHT WALL SLAB REDUCING SLABS SLAB DIAMETER Metric Imperial 1050 to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to 48 (Metric / Imperial) mm / in. LAID HT. Metric Imperial to MASS/WEIGHT Kg Lbs SLAB THICKNESS Metric Imperial WALL THICKNESS Metric Imperial M22

24 STANDARD GRADE RINGS 600 to 750 mm DIAMETER and 610 x 610 mm SQUARE 24 to 30 in. DIAMETER and 24 x 24 in. SQUARE GRADE RINGS (Metric) mm A B TOP VIEW STANDARD OPENINGS 600mm/24 in. 675mm/27 in. 750mm/30 in. ROUND GRADE RINGS GRADE RING DIA. / SIZE x 610 Nova Scotia only OUTSIDE DIAMETER x x x LAID HT. A WALL THK. B New Brunswick only MASS kg A B STANDARD OPENING 610 x 610 / 24" x 24" GRADE RINGS GRADE RING DIA. / SIZE x 24 OUTSIDE DIAMETER (Imperial) in. LAID HT. A WALL THK. WEIGHT B lbs x x x Nova Scotia only New Brunswick only + SQUARE GRADE RINGS M23

25 MANHOLE TEE BASE 750 to 3600 mm DIAMETER 30 to 144 in. DIAMETER 2438mm 96 in. AS REQUIRED 1397 or 1575mm SQUARE 55 or 62 in. SQUARE TOP VIEW SINGLE OFFSET JOINT 1050 or 1200mm SHAFTING 42 or 48 in. SHAFTING 152mm 6 in. 191mm 7.5 in. 750 to 3600mm 30 to 144 in. OPTIONAL SUPPORT BASE NOTE: See manhole assembly chart page M17 M24

26 MANHOLE TEE BASE BEND 750 to 3600 mm DIAMETER 30 to 144 mm DIAMETER AS REQUIRED TOP VIEW SINGLE OFFSET JOINT 1050 or 1200mm SHAFTING 42 or 48 in. SHAFTING 152mm 191mm 6 in. 7.5 in. 750 to 3600mm 30 to 144 in. 102mm MINIMUM 4 in. MINIMUM OPTIONAL SUPPORT BASE NOTE: See manhole assembly chart page M17 M25

27 MANHOLE BENCHING WITH GASKETS Standard configurations - Available from stock SINGLE OFFSET JOINT BENCHING T-JUNCTION CAST-IN GASKET o 90 BEND BENCHING 610mm (24 in.) 1219mm (48 in.) o 180 or DEAD END NOTE: 2% GRADE ACROSS MANHOLE BENCHING (Metric / Imperial) o o MANHOLE T-JUNCTION 90 BEND 180 /DEAD END DIAMETER PVC PVC PVC 203/8 203/8 203/8 1050/ /10 254/10 -- /12 /12 LAID HEIGHT 610/24 610/24 610/ / /8 610/24 and 1219/ /10 610/24 and 1219/ /12 610/24 and 1219/ /15 915/36 and 1219/ /18 915/36 and 1219/48 M26

28 MAXIMUM PIPE SIZES FOR MANHOLES 1050 to 3600 mm DIAMETER 42 to 144 in. DIAMETER MIN. ANGLE BETWEEN PIPE 150 mm 6" min. 150mm 6" min. 150 mm 6" min. IN CONCRETE PIPE MANHOLE DIAMETER 1050 / / / / / / / / / 42 & 1200 / 48 & 1500 / 60 BASE or SECTION MAX. PIPE SIZE C/W G-LOCK GASKET 533 / / / 15 / / / / / / / / / / / / / / 60 (SO) 1219 / / / 72 (SO) 1524 / 60 (S0) 1219 / / 72 (SO) 1524 / 60 (SO) 1219 / 48 PVC \ DUCTILE IRON (DI) PIPE 457 / / / 24 ECONO GASKET 102 / / / 8 254/ 10 / / 14 (DI) 381 / mm 6" min. MIN. ANGLE BETWEEN PIPE MAX. ROUGH CUT ACCESS 724 / / / / / / / / / / / / / / / / / / / / / / / / / 60 - (SO) designates special order units The minimum concrete required between pipe openings in all directions = 150mm / 6 in. - See page M17 for base units, M18 for intermediate sections and page M26 for benching and gaskets OUT 521 / / / / / / / / / /17.5 MIN. ANGLE BETWEEN PIPE MIN. BASE HEIGHT 1200 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 30 M27

29 SINGLE OFFSET JOINT DETAIL 600 / 24 and 750 mm / 30 in. DIAMETER CAST IRON FRAME AND COVER. GRADE RING COVER INTERMEDIATE SECTION SEE JOINT SEALS PAGE M29 ECCENTRIC CONES EC2, EC3 AND EC4 INTERMEDIATE SECTION M28

30 STANDARD MANHOLE JOINT SEALS Manholes, sewage lift stations, catchbasins and valve chambers SINGLE OFFSET GASKET NOTES: 1) The BELL and SPIGOT must be cleaned and lubricated, if required, prior to assembling each unit. 2) The SINGLE OFFSET GASKET must be placed as per manufacturer s recommendations around the spigot end of the pipe. The gasket must be placed tight to the spigot shoulder. (See pages P11 and P12) BUTYL SEALANT 3) Each unit must be placed squarely on top of the other to prevent the gasket from unseating itself and damaging the unit. SINGLE OFFSET GASKET AND BUTYL SEALANT CONFINED "O"-RING DETAIL NOTE: From time to time we may have to revert back to our old gasket system to meet supply and demand conditions (see page P13). M29

1E0 T: F: T: F:

1E0 T: F: T: F: UNDERGROUND PRODUCTS 2018A PRICE LIST 2150 Richardson Side Road Carp, Ontario K0A 1L0 T: 1-800-267-5515 F: 613-831-2048 SalesCarp@mconproducts.com 2691 Greenfield Road Ayr, Ontario N0B 1E0 T: 1-866-537-3338

More information

PRICE LIST UNDERGROUND PRODUCTS Greenfield Road Ayr, Ontario N0B 1E Richardson Side Road Carp, Ontario K0A 1L0

PRICE LIST UNDERGROUND PRODUCTS Greenfield Road Ayr, Ontario N0B 1E Richardson Side Road Carp, Ontario K0A 1L0 UNDERGROUND PRODUCTS 2018 PRICE LIST 2150 Richardson Side Road Carp, Ontario K0A 1L0 T: 1-800-267-5515 F: 613-831-2048 SalesCarp@mconproducts.com 2691 Greenfield Road Ayr, Ontario N0B 1E0 T: 1-866-537-3338

More information

PRICE LIST UNDERGROUND PRODUCTS Greenfield Road Ayr, Ontario N0B 1E Richardson Side Road Carp, Ontario K0A 1L0

PRICE LIST UNDERGROUND PRODUCTS Greenfield Road Ayr, Ontario N0B 1E Richardson Side Road Carp, Ontario K0A 1L0 UNDERGROUND PRODUCTS 2017 PRICE LIST 2150 Richardson Side Road Carp, Ontario K0A 1L0 T: 1-800-267-5515 F: 613-831-2048 SalesCarp@mconproducts.com 2691 Greenfield Road Ayr, Ontario N0B 1E0 T: 1-866-537-3338

More information

INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS

INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS 2.1 Sanitary Sewer Design Sheet 2.2 Hydraulic Elements Graph for Circular Sewers 2.3 Standard Servicing Locations for

More information

CONCRETE PIPE SPECIFICATIONS

CONCRETE PIPE SPECIFICATIONS CONCRT INX INX P...SINGL OFFST JOINT (Metric) P...SINGL OFFST JOINT (Imperial) P...CONCRT SHIPPING WIGHTS (Canadian) P4...CONCRT SHIPPING WIGHTS (State of Maine) P5...ALTRNAT CONCRT LNGTHS P6... BNS P7...T

More information

Road + Civils AG.UK.COM

Road + Civils AG.UK.COM Road + ivils AG.UK.OM Road + ivils Road + ivils drainage products AG.UK.OM DRAINAG PRODUTS PRODUT RANG Manhole Rings oncrete access chambers Shaft / Available depth of section chamber section DN 0.25m

More information

DWV PVC DWV Drain Waste Vent Fittings

DWV PVC DWV Drain Waste Vent Fittings STANDARDS & SPECIFICATIONS Standards provide greater assurance of product performance and consistency, and are available to assist design engineers in system specification. The most frequently referenced

More information

PRODUCT DESCRIPTION 1500 RECT 2/C Gallon 2 Compartment Septic Tank TOP VIEW. Rectangular lid has optional

PRODUCT DESCRIPTION 1500 RECT 2/C Gallon 2 Compartment Septic Tank TOP VIEW. Rectangular lid has optional 1500 Gallon 2 Compartment Septic Tank 52.0 1.0 Taper Outlet and Inlet 24 O.D. with manhole cover. 4500psi @ 28 days Our septic tanks have 3 optional inlets and 1 outlet 55 from bottom of tank to bottom

More information

CATALOGUE SEWAGE MANHOLES

CATALOGUE SEWAGE MANHOLES CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch

More information

Flexible Couplings & Saddles

Flexible Couplings & Saddles Revised 6/01 Flexible Sewer couplings are the result of many years of experience with sewer pipe connections. Today's couplings are made of specially formulated elastomeric PVC with high tear and shear

More information

ADDENDUM #1 NWIT Watermain Replacement Program New Westminster, BC

ADDENDUM #1 NWIT Watermain Replacement Program New Westminster, BC June 20, 207 ADDENDUM # NWIT723 207 Watermain Replacement Program New Westminster, BC This addendum modifies the Invitation to Tender only as noted: INSTRUCTIONS TO TENDERERS PART I 3.0 Submission of Tenders

More information

ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS.

ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS. ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS www.bow-group.com dimension item Ctn Skid list price dimension item Ctn Skid list price SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007

More information

Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE)

Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE) Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE) July 2013 1 Material July 2013 7 Production Material Polyethylene (PE) Virgin material 100 % Recycling-contents Foam-contents

More information

Reference Data. Schedule 40 Steel Pipe Data. Schedule 80 Steel Pipe Data

Reference Data. Schedule 40 Steel Pipe Data. Schedule 80 Steel Pipe Data Schedule 40 Steel Pipe Data Maximum Recommended Pipe Size Pipe O.D. Thickness Weight of Pipe Filled With Water Span* Hanger Rod Ft. Meter Sizes 3/8" (10).675 (17.1).091 (2.3).6 (.9).7 (1.0) 7 (2.13) 3/8"-16

More information

DRAINAGE. December

DRAINAGE. December DRAINAGE December 2017-1 TAB - 2501 STATEMENT OF ESTIMATED QUANTITIES TAB SHT NO ITEM DESCRIPTION UNITS ARPONS TOTAL ESTIMATED QUANTITY D 25 2104.502 CATCH BASIN EACH 1 D 25 2104.502 S EACH 9 D 25 2104.503

More information

TENDER FOR COUNTY ROAD 44 MULTI-USE PATHWAY PHASE 1A & 1B. Tender No.: NG16-19 ADDENDUM #1. October 31, 2016

TENDER FOR COUNTY ROAD 44 MULTI-USE PATHWAY PHASE 1A & 1B. Tender No.: NG16-19 ADDENDUM #1. October 31, 2016 TENDER FOR COUNTY ROAD 44 MULTI-USE PATHWAY PHASE 1A & 1B Tender No.: NG16-19 ADDENDUM #1 October 31, 2016 A copy of this addendum must be enclosed with your tender. Failure to comply with this requirement

More information

Macon Plastics, Inc Fax

Macon Plastics, Inc Fax Macon Plastics, Inc. 888.782.2722 478.743.6828 Fax 478.743.6819 Surface Drainage Products Catalog The Starting Point for your Storm Water Drainage Solutions! Drain Basins, Inline Drains, Curb Inlets, Road

More information

Grate Sq. In. 3-Sided 4-Sided Grate Description Frame Option Option Opening Perimeter Perimeter

Grate Sq. In. 3-Sided 4-Sided Grate Description Frame Option Option Opening Perimeter Perimeter drainage tables round grates drainage tables catch basin grates drainage Tables round grates (continued) Grate Manhole Catch Basin Sq. In. Grate Wier Grate Description Frame Series Option Grate Dia. Grate

More information

ABS-C0219 FEB SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS.

ABS-C0219 FEB SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS. ABS-C0219 FEB. 2019 SUPERSEDES ABS-C0717R CSA B181.1 ABS DWV FITTINGS www.bow-group.com DIMENSION ITEM CTN SKID LIST PRICE DIMENSION ITEM CTN SKID LIST PRICE SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007

More information

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation Reliable backwater protection Protection from backwater Backwater Protection - things you need to know Prevention Not properly protecting a building against backwater can result in damage that is extremely

More information

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries Septic tanks A septic tank from Ri-Industries offers a number of benefits: Engineer-designed and built from fine tolerance steel moulds Tanks are made from 40 MPa concrete to give additional strength and

More information

SUPERSEDES ABS-C0811/AUG.

SUPERSEDES ABS-C0811/AUG. ABS-C0612/R JUNE 2012 SUPERSEDES ABS-C0811/AUG. 2011 SANITARY TEE REDUCING TEE TEE - Left Side Inlet 600007 1 1/4" 0 62852 60000 5 50 4,800 15.41 600015 1 1/2" 0 62852 60001 2 90 2,880 8.27 600023 2"

More information

Concrete Pipes 62 Traditional Manholes Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69

Concrete Pipes 62 Traditional Manholes Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69 Concrete Drainage & Accessories CPM Concrete Pipes 62 Traditional Manholes 63-65 Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69 F P McCann Concrete Pipes / Precast

More information

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC)

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC) LINEAR CAPTURE Perpendicular collection across the full width of a drainage surface such as a parking deck, street or sloped residential driveway. Excavation area and depth are less than for conventional

More information

516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS

516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS Date Printed: November 2010 FIRE HYDRANTS or Tyton (6"),6, or 8" A EDDY FIRE HYDRANTS PARTS LIST WORKING PRESSURE: 150 PSI Note: Discontinued For Reference Only 350 PSI Working Pressure

More information

13-17 Endurance Avenue Queanbeyan NSW 2620 Ph: Fax:

13-17 Endurance Avenue Queanbeyan NSW 2620 Ph: Fax: 13-17 Endurance Avenue Queanbeyan NSW 2620 Ph: 02 6299 3422 Fax: 02 6299 3423 Situated in Queanbeyan, NSW, and a leading supplier to the ACT and local region, Capital Precast and Drainagestocks the complete

More information

REGIONAL CATALOG: TEXAS

REGIONAL CATALOG: TEXAS REGIONAL CATALOG: TEXAS Thank you for your interest in US Foundry Products. This Regional Catalog has been developed to show the most commonly used and specified Municipal Castings for the Texas area.

More information

INDEX. Growing Beyond Boundaries 03

INDEX. Growing Beyond Boundaries 03 INDEX Company Profile 01 Facilities 02 Product Selector 04 Products at a glance 05 Category Carriageway/Telecom Covers 06 Square/Rectangular Frames and Covers 11 Circular Frames and Covers 22 Recessed

More information

Ductile Iron. Fittings and Accessories for pressure pipelines. 1 st issue

Ductile Iron. Fittings and Accessories for pressure pipelines. 1 st issue Ductile Iron Fittings and Accessories for pressure pipelines 1 st issue INTRODUCTION Tawakol Metal Industries is Egypt's main manufacturer of Grey and Ductile Cast Iron products since 1975. TMI's reputation

More information

Industries. Septic Tanks

Industries. Septic Tanks Industries Septic Tanks South Australia s leading manufacturer of pre-cast concrete products including Ri Treat waste water treatment, trades waste arrestors, septic tanks and rainwater tanks www.ri-industries.com.au

More information

UBC Watermain as shown on Sheet 202 : Sub total 97,050

UBC Watermain as shown on Sheet 202 : Sub total 97,050 Preliminary Cost Estimate Brock Commons Phase 1 Watermain replacement UBC Portion of Works only Replace existing 150mm dia CI and 200mm dia AC watermain with 200mm & 250mm dia DI (ductile iron) watermain

More information

h Technical Product Data CC Pressure Pipe Systems

h Technical Product Data CC Pressure Pipe Systems h Technical Product Data CC Pressure Pipe Systems Amiblu Holding GmbH All rights reserved. Publication: 09/2018 This version replaces all previous versions. For all current data please visit our website

More information

Project Book Worksheet for Cost Estimation

Project Book Worksheet for Cost Estimation 001.01 MOBILIZATION LS $34,716.18 007 3/17/2039 001.02 INCIDENTAL LS $23,929.43 019 3/17/2039 001.03 CONSTRUCTION STAKING LS $10,504.39 201 5/9/2013 001.04 REESTABLISH PROPERTY CORNERS EA $496.08 201 5/9/2013

More information

Basins, Floats & Accessories

Basins, Floats & Accessories Basins, Floats & Accessories Aqua Pro Pump Systems a Tomiko Inc. Company APPS Basins, Floats & Accessories BasinS Basin Size Gallons Weight 24 X 48 94 55 24 X 60 118 63 24 X 72 141 70 24 X 84 165 88 30

More information

SANITARY SCHEDULE ALIGNMENT CODES: 'ES'= EAU CLAIRE AVENUE SB UTILITY REPLACEMENT WITH STREET RESURFACING - 2015 PROJECT NO. 53W1793 EAU CLAIRE AVE SANITARY SEWER SCHEDULE SHEET NO. U-6 CITY OF MADISON

More information

CITY OF STANDARD SPECIFICATIONS

CITY OF STANDARD SPECIFICATIONS CITY OF Published May 4, 2016 CALIFORNIA Stephan Kiefer, Community Development Director Cheri Sheets, City Engineer CITY OF LIVERMORE 1052 South Livermore Avenue Livermore, CA 94550 4DEV0001.doc 03/12

More information

Fiberglass Basins with Ballast Support Flange 24" thru 72" Dia. (.6m thru 1.8m)

Fiberglass Basins with Ballast Support Flange 24 thru 72 Dia. (.6m thru 1.8m) Specifications: Fiberglass Basins with Ballast Support Flange 24" thru 72" Dia. (.6m thru 1.8m) Standard: Basin construction is custom molded fi berglass reinforced polyester resin. The wall thickness

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTNTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

McCRORY & WILLIAMS, INC. HILLCREST ROAD CONNECTOR MCR ROADWAY ITEMS

McCRORY & WILLIAMS, INC. HILLCREST ROAD CONNECTOR MCR ROADWAY ITEMS BID TABULATION Hillcrest Road Connector John G. Walton Construction M. C. Williams Contracting Hosea. Weaver & Sons, Inc. BID OPENING: March 25, 29 Company, Inc. Company, Inc. QTY DESCRIPTION DOLLARSjCTS

More information

APCO SURGE RELIEF ANGLE VALVES (SRA)

APCO SURGE RELIEF ANGLE VALVES (SRA) BULLETIN 3000 MARCH 2018 APCO SURGE RELIEF ANGLE VALVES (SRA) Design & Construction APCO Surge Relief Angle Valves (SRA) are designed to limit surge pressure and the potential damage to the pump system.

More information

CP #CP218 NAIL SOFT GROUND N= E= ELEV= GUY WIRE. + WV CP #CP175 Old Magnail N= E= ELEV=858.

CP #CP218 NAIL SOFT GROUND N= E= ELEV= GUY WIRE. + WV CP #CP175 Old Magnail N= E= ELEV=858. O R IG IN A T O R : C IT Y OF M A D IS O N, S T R E E T S DIV IS IO N 805 4906 802 813 4910 821 825 DELAWARE LN 1 2 3 EROSION CONTROL MEASURES SHALL BE IN PLACE PRIOR TO ANY OTHER CONSTRUCTION ACTIVITY

More information

Maine Turnpike Authority

Maine Turnpike Authority Interchange 44 Barrier Toll Plaza Open Road Tolling Conversion Mile 44.3 201.11 CLEARING 3.50 AC 202.071 REMOVING ASBESTOS CONTAINING MATERIALS, TOLL BOOTH LAB TOPS 1.00 LS 202.081 REMOVING EXISTING BUILDING

More information

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe Joint Restraint Products PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe INFORMATION The PVC Stargrip Mechanical Joint Restraint System is a unique product with

More information

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe INFORMATION The PVC Stargrip Mechanical Joint Restraint System is an exceptional restraint system for mechanical

More information

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates Flexible Couplings Transitions all types of DWV plastic, copper, steel, cast iron and clay pipe. 300 series stainless steel clamps Flexibility - Sleeve is manufactured of molded natural and synthetic rubber

More information

ACO Qmax Unit size

ACO Qmax Unit size ACO Qmax 50 ACO Qmax 50 ACO Qmax 50 The ACO Qmax 50 channel is manufactured from recycled MDPE which is lightweight, chemically resistant and extremely robust. Its circular bore, ed push fit channel connections

More information

PRECAST CONCRETE SPECIALISTS. Product Catalogue

PRECAST CONCRETE SPECIALISTS. Product Catalogue PRECAST CONCRETE SPECIALISTS Product Catalogue Roodepoort Pipe s manufacturing and storage facility. HEAD OFFICE, P O Box 92, Roodepoort 1725, Tel: (011) 670-7600, Fax: (011) 472-5754 E-mail: info@rocla.co.za

More information

Series G. STI Gasketed Sewer Fittings SDR 35 STI. Injection Molded in Sizes 4 12 Fabricated in Sizes STI Gasketed Sewer SDR 35 G Series

Series G. STI Gasketed Sewer Fittings SDR 35 STI. Injection Molded in Sizes 4 12 Fabricated in Sizes STI Gasketed Sewer SDR 35 G Series Gasketed Sewer ittings SDR 35 Third party tested and listed by NS, UPC and CSA to meet specifications defined in ASTM D3034, 1336 and CSA B182.2. Gasketed Sewer ittings SDR 35 Gasketed Injection Molded

More information

Introduction. Eccles (UK Foundries FE) Ltd has a group experience of some 77 years in the manhole cover industry.

Introduction. Eccles (UK Foundries FE) Ltd has a group experience of some 77 years in the manhole cover industry. Introduction Eccles (UK Foundries FE) Ltd has a group experience of some 77 years in the manhole cover industry. All products are manufactured in accordance with the industry standard BS EN 124: 1994 which

More information

2018 CATALOGUE CONCRETE PITS COVERS & GRATES ...& A WEALTH OF KNOWLEDGE. Phone:

2018 CATALOGUE CONCRETE PITS COVERS & GRATES ...& A WEALTH OF KNOWLEDGE.   Phone: 2018 CATALOGUE CONCRETE PITS COVERS & GRATES...& A WEALTH OF KNOWLEDGE www.civilcast.com.au Phone: 02 9833 4999 ABOUT CIVILCAST Civilcast is an Australian owned company specialising in the supply of stormwater,

More information

2150 F&I 4" PVC pipe LF 100 $ F&I 6" PVC pipe LF 100 $ F&I 8" PVC pipe LF 100 $ 90.00

2150 F&I 4 PVC pipe LF 100 $ F&I 6 PVC pipe LF 100 $ F&I 8 PVC pipe LF 100 $ 90.00 1 of 5 2100 F&I 4" ductile iron pipe LF 200 $ 143.00 $28,600.00 2102 F&I 6" ductile iron pipe LF 200 $ 135.00 $27,000.00 2104 F&I 8" ductile iron pipe LF 200 $ 141.00 $28,200.00 2105 F&I 10" ductile iron

More information

Water, Sewer & Drain Fittings

Water, Sewer & Drain Fittings Why Compact? Compact Joint are manufactured from a high strength, impact resistant ductile iron that offers a great margin of safety against service failures and provides vastly increased resistance to

More information

MIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax:

MIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax: Product Catalog Table of Contents Item Page # Septic Tanks 1 Septic System Accessories 2 Frost Free Stock Tank 3 Feed Bunks 4 Storm Shelter 5 Parking Blocks 6 Pads & Blocks 7 Tiles 8 Pump Pit 9 Steps 10

More information

Joint Restraint System

Joint Restraint System Joint Restraint System For IPS, DPS & DIN Plastic Pipe 10-YEAR Warranty Parts & Labor ask for details PIPE TO FITTING LH-Series 2-12 IPS Pipe s LHD-Series 4-24 DPS Pipe s DLH-Series 63-400MM DIN Pipe s

More information

POWER & INFRASTRUCTURE SOLUTIONS

POWER & INFRASTRUCTURE SOLUTIONS POWER & INFRA- STRUCTURE POWER & INFRASTRUCTURE SOLUTIONS v.2.2 CABLE DUCTING BT COMMS BOXES CABLE TROUGH SYSTEMS FIRE & BLAST WALLS FPMCCANN.CO.UK Magherafelt UddingSton Alnwick Lisnaskea ARMAGH Weston

More information

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649

More information

AUTOMATION ACCESSORIES IN-PLANT VALVE PRODUCTS EXTENSION STEMS FLOORBOX STEM GUIDES FLOORSTANDS COMMITTED TO ENVIRONMENTAL RESPONSIBILITY FLAP VALVES

AUTOMATION ACCESSORIES IN-PLANT VALVE PRODUCTS EXTENSION STEMS FLOORBOX STEM GUIDES FLOORSTANDS COMMITTED TO ENVIRONMENTAL RESPONSIBILITY FLAP VALVES INCREASING SWING CHECK VALVES FLAP VALVES SWING CHECK VALVES AUTOMATION ACTUATION CLOW VALVE has furnished valves with many assorted types of motorized to operate our valves. The gate valves use multi-turn,

More information

A u t o matic Backw ater V alve

A u t o matic Backw ater V alve A u t o matic Backw ater V alve P R O TECT YOUR I N V E S TMENT S INDEX PAGE FLOOD-GATE FEATURES Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Fully mechanical

More information

Whapmagoostui First Nation. Main access ("B" street) Residential expansion - Phase 1 option D LIST OF MATERIALS. Revision Art.

Whapmagoostui First Nation. Main access (B street) Residential expansion - Phase 1 option D LIST OF MATERIALS. Revision Art. 1.0 Water distribution system Ductile cast iron pipe Ø150mm pre-insulated pipe (insulation thickness = 1.1 50 mm), Class 52 Tyton joints, conductivity stripe, (including insulation kit m 780 $ for joints)

More information

INSERTA VALVE SLEEVE INSERTA VALVE ASSEMBLY. Valve insertion, simplified MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS.

INSERTA VALVE SLEEVE INSERTA VALVE ASSEMBLY. Valve insertion, simplified MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS. MADE IN U.S.A. Valve insertion, simplified 10-12 installations in cast iron, ductile iron, A/C, PVC C-900 and steel pipe No Loss of Pressure Minimal Water Loss Completion time is less than 2 hours Much

More information

INSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents

INSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents INSTALLATION GUIDE Model #GB2 35/50 GPM Grease For Indoor Use Contents Special Precautions............................................ 2 Getting to Know the GB2....................................... 3

More information

CASING SPACERS DESIGNED FOR WATER, SEWER, OIL & GAS

CASING SPACERS DESIGNED FOR WATER, SEWER, OIL & GAS CASING SPACERS DESIGNED FOR WATER TER,, SEWER,, OIL & GAS The BWM Company P.O. Box 1 Forest City, North Carolina 2803 Phone: 828.27.030 Toll Free 8 5 SPACER Fax: 828.25.59 www.bwmcompany.com BWM will provide

More information

GENERAL FOUNDRIES

GENERAL FOUNDRIES GENERAL FOUNDRIES 00--9555 INDEX MANHOLE COVER TYPES NEW JERSEY 1 MANHOLE RINGS AND COVERS 3 CATCH BASINS 6 CURB AND GUTTER 10 NJDOT INLETS SUMMARY 1 NEW YORK 1 MANHOLE RINGS AND COVERS 15 CATCH BASINS

More information

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL Item No.s/Description Item No. Description Material Specification HYDRANT Qty. Req d Item No. Description Material Specification 1 Operating

More information

ABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT ABS DWV FITTINGS.

ABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT ABS DWV FITTINGS. ABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT. 2018 ABS DWV FITTINGS www.bow-group.com COUPLING 1 1/4" 601112 125 9,000 5.63 1 1/2" 601120 125 9,000 3.48 2" 601138 100 4,800 4.65 3" 601146 45 1,440 13.07

More information

TABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44

TABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44 TABLE OF CONTENTS Item Page Item Page ANSI/AWWA Compact & Full Body Pipe Fittings: Product Submittals and Installation: Mechanical & Flange Joint C153. 3-9 20U Protective Fusion Bonded Epoxy....5,5 Mechanical

More information

Project # & Name: # CDBG - Pugh Street Streetscape - East College Ave to East Beaver Ave & East Beaver Ave/Locust Lane Improvements

Project # & Name: # CDBG - Pugh Street Streetscape - East College Ave to East Beaver Ave & East Beaver Ave/Locust Lane Improvements Bid Opening Date: May 6, 2014 Time: 11:00 a.m. Surety NCA Surety NCA Yes Yes Yes Yes Total Amount Bid: $1,358,851.00 Total Amount Bid: $1,386,098.72 Item Nos. Approx. Quantities Unit Item & Unit Prices

More information

ABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661

ABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661 ABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661 COUPLING 1 1/4" 601112 125 9,000 3.36 1 1/2" 601120 125 9,000 2.25 2" 601138 100 4,800 3.03 3" 601146 45 1,440 8.49 4" 601153 25 800

More information

Table of Contents. Item Page #

Table of Contents. Item Page # Product Catalog 1 Table of Contents Item Page # Septic Tanks 2 Septic System Accessories 3 Frost Free Stock Tank 4 Feed Bunks 5 Storm Shelter 6 Parking Blocks 7 Pads & Blocks 8 Tiles 9 Pump Pit 10 Steps

More information

MODEL 5A SPECIFICATION

MODEL 5A SPECIFICATION MODEL 5A SPECIFICATION 1.0 General Specifications There shall be furnished one (1) one only Grind Hog TM Model 5A HEAVY DUTY Comminutor as manufactured by G.E.T. Industries Inc. with rotation in a counter-clockwise

More information

water management product catalog

water management product catalog water management product catalog INTRODUCTON Our Thinking Continues to Make Waves. From construction and agriculture to residential and recreation, Hancor offers innovative drainage solutions for a variety

More information

HYDRA-CELL PIT SYSTEM KNOCK-OUT PIT

HYDRA-CELL PIT SYSTEM KNOCK-OUT PIT HYDRA-CELL - 1050 PIT SYSTEM Page Ref: HC 01 C-M ROAD GULLY UNIT RISER MODULES for HYDRA-CELL 1050 Module Height 150mm 300mm 600mm 900mm 1200mm Jump pit Ø 1050 RISER ASPRO Ø 1050 HYDRA-CELL Ø 1050 HYDRA-CELL

More information

JUST PIPING, JUST FITTING. A Comprehensive Integrated Solution For Piping Systems

JUST PIPING, JUST FITTING. A Comprehensive Integrated Solution For Piping Systems JUST PIPING, JUST FITTING A Comprehensive Integrated Solution For Piping Systems SF 01 DUCTILE IRON PIPE FITTINGS FD1011 FD1021 FD1022 FD1031 FD1102 FD1103 FD1111 FD1121 Double Flanged Piece Flanged spigot

More information

Iron Check Valves Illustrated Index

Iron Check Valves Illustrated Index Iron Check Valves Illustrated Index Iron Body Swing Check Valve Bronze Mounted or All Iron 125 lb. SWP 200 lb. CWP Iron Body Swing Check Valve Bronze Mounted 250 lb. SWP 500 lb. CWP Iron Body Silent Check

More information

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY For the most up-to-date version of this price list, EFFECTIVE MARCH 4, 2019 ENGINEERED FOR DURABILITY HARRINGTON CORPORATION P.O. BOX 10335 LYNCHBURG, VIRGINIA 24506-0335 For the most up-to-date version

More information

MODEL 7ASX-8 SPECIFICATION

MODEL 7ASX-8 SPECIFICATION MODEL 7ASX-8 SPECIFICATION 1.0 General Specifications There shall be furnished one (1) one only Grind Hog TM Model 7ASX-8 HEAVY DUTY Comminutor as manufactured by G.E.T. Industries Inc. with rotation in

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

PRESSURE UTILITIES. Pipe flow occurs due to contents of the pipe being pressurized System cannot have a free connection to the atmosphere

PRESSURE UTILITIES. Pipe flow occurs due to contents of the pipe being pressurized System cannot have a free connection to the atmosphere PRESSURE UTILITIES Pipe flow occurs due to contents of the pipe being pressurized System cannot have a free connection to the atmosphere Types of Pressure Utilities Domestic Water: Clean/drinkable water

More information

ABS DWV FITTINGS APRIL 1, 2013

ABS DWV FITTINGS APRIL 1, 2013 LIST C10-11-111 ABS DWV FITTINGS APRIL 1, 2013 SUPERSEDES C10-11-110 (JUNE 1, 2012) Our website pricing is the current list price and may vary from our printed price list. Please visit our website for

More information

Maine Turnpike Authority

Maine Turnpike Authority York Toll Plaza Mile 8.8 201.11 Clearing 17.00 AC 202.15 Removing Existing Manhole or Catch Basin 22.00 EA 202.151 Abandoning Existing Manhole or Catch Basin 10.00 EA 202.16 Removing Existing Pipe 575.00

More information

EMCO WHEATON RETAIL CORPORATION

EMCO WHEATON RETAIL CORPORATION Manholes A0721 Monitoring Well Manholes 2-3 A0717 Standard Manholes, Round 8-9 A0717 Square Manholes & Vaults 4-6 A0716 Composite Manholes 10-11 A0727/A0728 Well Protectors 7 EMCO WHEATON RETAIL CORPORATION

More information

PVC Pressure Piping Systems for Water Transmission

PVC Pressure Piping Systems for Water Transmission PVC Pressure Piping Systems for Water Transmission MUNICIPAL SYSTEMS PVC PRESSURE PIPING SYSTEM MANUFACTURED TO AWWA & CSA STANDARDS IPEX Centurion 14" 60" (350mm 1,500mm), AWWA C905 and CSA Standards

More information

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve CSO/STORMWATER MANAGEMENT HYDROVEX CCV Check Valve HYDROVEX CCV CIRCULAR CHECK VALVE APPLICATION The HYDROVEX CCV Check Valve is designed for use in water and sewage. It has no reinforcement and is especially

More information

BID TABULATION REPORT McKINNEY STREET DRAINAGE IMPROVEMENTS PROJECT No. PWDR10012 BID OPENED : TUESDAY, AUGUST 13, :00 P.M.

BID TABULATION REPORT McKINNEY STREET DRAINAGE IMPROVEMENTS PROJECT No. PWDR10012 BID OPENED : TUESDAY, AUGUST 13, :00 P.M. PAVING IMPROVEMENTS McKINNEY 101 Rightofway Preparation LS 1 75,000.00 75,000.00 200,000.00 200,000.00 67,000.00 67,000.00 110,000.00 110,000.00 102 12inch HMAC Street Pulvermix SY 11,650 3.00 34,950.00

More information

Ford Brass Saddles Style 101B and 202B

Ford Brass Saddles Style 101B and 202B 101B Ford Brass Saddles 101B and 202B 101B, 3/4" and 1" Taps 202B, 3/4" through 2" Taps Specifications Body - 85-5-5-5 brass alloy as per ASTM B62, ASTM B584 and AW WA C800. Threads may be FIP, AW WA,

More information

Mid-States Concrete Industries flexicore

Mid-States Concrete Industries flexicore 2" STRUCTURAL TOPPING (2 HOUR FIRE RATING) COMPOSITE DESIGN 1.75-108 10-1/2 1.530 254.02 229 219 209 200 192 183 168 155 143 131 121 111 1.75-28410 2-1/2,4-.6 1.174 204.16 326 308 292 278 264 251 231 210

More information

The Pump Matic Range

The Pump Matic Range The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality

More information

B U I L D I N G C O N N E C T I O N S T H AT L A S T

B U I L D I N G C O N N E C T I O N S T H AT L A S T B U I L D I N G C O N N E C T I O N S T H AT L A S T pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior

More information

GWE Street Expansion (Phase 2) LIST OF MATERIALS. Unit Qty Unit price Total. unit 3 $

GWE Street Expansion (Phase 2) LIST OF MATERIALS. Unit Qty Unit price Total. unit 3 $ 1.0 Water distribution system Ductile cast iron pipe Ø150mm pre-insulated pipe (insulation thickness = 50 1.1 mm), Class 52 Tyton joints, conductivity stripe, (including insulation kit for m 540 $ joints)

More information

BIDDER'S PROPOSAL (continued) CITY OF BERKELEY BID PROPOSAL ITEM NO. A: BASE BID

BIDDER'S PROPOSAL (continued) CITY OF BERKELEY BID PROPOSAL ITEM NO. A: BASE BID SPECIFICATION 16-11031-C CITY OF BERKELEY BID PROPOSAL A: BASE BID 1 MOBILIZATION 1 LS 2 TRAFFIC CONTROL 1 LS 3 CONTRACTOR INFORMATION SIGN 2 EA 4 CONSTRUCTION AREA SIGN 18 EA 5 PROJECT IDENTIFICATION

More information

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com RESILIENT SEATED BUTTERFLY VALVES Howell Valve & Automation Toll Free: 1-888-469-3557 Howellvalve.com TABLE OF CONTENTS Description Page Index 2 Resilient Standard Features 3 ST Boot Series with BUNA-N

More information

Section 200 Page 1 Effective: January 15, 2013 Supersedes: June 1, 2012

Section 200 Page 1 Effective: January 15, 2013 Supersedes: June 1, 2012 Section 200 Page 1 HPG200 - Submersible Grinder Pump Model Volt/Ph Imp Dia-in. Cord Wt. (lbs.) Part Number List Price HPG200M2-2 230/1 5.5 20' 82 526031007 $2,549 HPG200M3-2 230/3 5.5 20' 82 526031017

More information

Design Aids For Structural Welded Wire Reinforcement (Metric Units for WWR/Rebar Comparison Tables)

Design Aids For Structural Welded Wire Reinforcement (Metric Units for WWR/Rebar Comparison Tables) TF 209-R-08 Metric Design Aids For Structural Welded Wire Reinforcement (Metric Units for WWR/Rebar Comparison Tables) INTRODUCTION This Tech Fact* provides basic information on coldworked wire and welded

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD channel drainage system Technical Data ACO MultiDrain MD Introduction to the

More information

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN TECNICA type SE The polyester concrete drainage with 4mm protective edge profi le IMC SE 5-5 EN TECNICA SE - SE5 - SE2 - SE3 EN 433 Class D4 - E6 Due to their low weight, high strength, good chemical resistance

More information

Pipe gasket range. Designed to make a difference. Designed to make a difference 1

Pipe gasket range. Designed to make a difference. Designed to make a difference 1 Pipe gasket range Designed to make a difference Designed to make a difference 1 How Gulf gaskets can make a difference to you Water, drainage, sewerage - when it comes to sealing pipes, it s clear that

More information

EN1401 Pipe & Fittings EN1401 Pipe & Fittings Quantum Pipe & Fittings 26-29

EN1401 Pipe & Fittings EN1401 Pipe & Fittings Quantum Pipe & Fittings 26-29 Plastic Drainage Polypipe Building s EN1401 Pipe & Fittings 10-20 Underground Drainage Systems Marley Plumbing & Drainage EN1401 Pipe & Fittings 22-24 Quantum Pipe & Fittings 26-29 Wavin OSMA EN1401 Pipe

More information

ABS DWV FITTINGS MARCH 1, 2017

ABS DWV FITTINGS MARCH 1, 2017 LIST U10-0317-IP ABS DWV FITTINGS MARCH 1, 2017 SUPERSEDES U10-1116-IP (NOVEMBER 1, 2016) Our website pricing is the current list price and may vary from our printed price list. Please visit our website

More information

Rated to the New, Higher Pressure Classes in Latest Editions of AWWA C900 and C909. Joint Restraint Products

Rated to the New, Higher Pressure Classes in Latest Editions of AWWA C900 and C909. Joint Restraint Products Pipe Restrainers series 1000G2 1000G2C Restrainers for AWWA CI OD C900/C909 PVC/PVCO Pipe with MJ or Ductile Iron Push-On Fittings (Formerly Series 9000) INFORMATION Second Generation (Gen 2) PVC Restrainers

More information

Design and Construction Standards SECTION PLUMBING PIPING

Design and Construction Standards SECTION PLUMBING PIPING SECTION 15420 PLUMBING PIPING PART 1 GENERAL 1.1 SCOPE A. Work consists of all plumbing work indicated on drawings and specified herein. Included are requirements for fees/permits for installation and

More information