Masterpact. Dimensions and connection. Masterpact NT06 to NT16 Fixed 3/4-pole device 54 Drawout 3/4-pole device 58
|
|
- John McKenzie
- 5 years ago
- Views:
Transcription
1 52
2 Dimensions and connection Presentation 1 unctions and characteristics 9 T06 to T16 ixed 3/4-pole device 54 Drawout 3/4-pole device 58 W08 to W32 ixed 3/4-pole device 62 Drawout 3/4-pole device 64 W40 ixed 3/4-pole device 66 Drawout 3/4-pole device 68 W40b to W63 ixed 3/4-pole device Drawout 3/4-pole device 72 T/W accessories 74 T/W external modules 76 Electrical diagrams 81 Installation recommendations 91 Additional characteristics References
3 Dimensions and connection T06 to T16 circuit breakers ixed 3/4-pole device Dimensions E (3P) 175 (4P) E ,5 39 0,5 3 1 (3P) 195 (4P) 1 ottom mounting (on base plate or rails) Rear mounting detail (on upright or backplate) E193A E192 6 Ø6,5 100 E194 4 Ø6,5 18 mini 39 maxi ,5 1 (3P) 195 (4P) , (3P) 195 (4P) 1 Safety clearances Door cutout Rear panel cutouts E59443A A (*) E195A A (*) E196A 194 mini (3P) 264 mini (4P) 194 mini E197A (1) 266 (2) (1) 244 (2) 97 (1) 122 (2) 108 (1) 3 (2) 100 (3P) 1 (4P) : Datum. Insulated Metal Energised parts parts parts A (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. A(*) An overhead clearance of 50 mm is required to remove the arc chutes. An overhead clearance of mm is required to remove the terminal block. 54
4 E210A Connections Horizontal rear connection E198A E199A 43,5 E4A ,5 67,5 123 E1 44 9,5 167, Ø11 Vertical rear connection E2A E3A 43,5 E4A ,5 E5 60 9, Ø11 detail ront connection E6A E7 12 E8A 0 Top connection ottom connection 326 E9 44 9,5 2 Ø Ø ,5 164 detail ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer 55
5 Dimensions and connection T06 to T16 circuit breakers ixed 3/4-pole device Connection ront connection with spreaders E211A E212A E2A E214A Rear connection with spreaders E219A E2A 98 E221A ,5 52,5 219,5 123 E222A ,5 Spreader detail Middle left or middle right spreader for 4P Middle spreader for 3P Left or right spreader for 4P Left or right spreader for 3P E234A 77 38,5 = =,5 E292A 77 38,5 = =,5 E293A 77 38,5 = =,5 E294A 77 38,5 = =, Ø Ø Ø Ø detail : Datum ote: and are the symmetry planes for a 3-pole device. 56
6 Connections ront connection via vertical connection adapters E2A E216A E217A E218A E210A 116, = 89 = (1) Ø ,5 3 detail ront connection via vertical connection adapters fitted with bare cable connectors. E231A E232A E233A E230A Ø 5 Ø11 detail ,5 357,5 ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer (1) 2 connection possibilities on vertical connection adapters (21 mm between centres) 57
7 Dimensions and connection T06 to T16 circuit breakers Drawout 3/4-pole device Dimensions E171C 210 mini E172A 1,5 (3P) 197,5 (4P) ,5 46 (*) mini 45, (3P) 160 (4P) 90 (*) disconnected position ottom mounting (on base plate or rails) Rear mounting detail (on upright or backplate) E174 E173 E175 4 Ø6,5 6 Ø6, (3P) 160 (4P) (3P) 179 (4P) 109 Safety clearances Door cutout Rear panel cutout E59444A A E176 C C E177 1 mini (3P) 240 mini (4P) 230 mini E178A 9 (1) 303 (2) (1) 183 (2) 109 (1) 0,8 (2) 9 (1) 307 (2) 102,5 (3P) 172,5 (4P) 102,5 Insulated Metal Energised parts parts parts A C : Datum. (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. 58
8 Connections Horizontal rear connection E179A E180A E181A E1 E189A 49 67, , ,5 44 9, Ø11 Vertical rear connection E182A E183A E184A ,5 E5 60 9, Ø11 detail ront connection E185A E186 E187A Top connection ottom connection 140 9, Ø11 37,9 9,5 235 E ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer 26 37,9 9,5 detail 44 2 Ø11 9,5 59
9 Dimensions and connection T06 to T16 circuit breakers Drawout 3/4-pole device Connection ront connection with spreaders E223A E224A E2A E226A Rear connection with spreaders Middle left or middle right spreader for 4P Middle spreader for 3P Left or right spreader for 4P Left or right spreader for 3P E234A 77 38,5 = =,5 E292A 77 38,5 = =,5 E293A 77 38,5 = =,5 E294A 77 38,5 = =, Ø Ø Ø Ø detail : Datum ote: and are the symmetry planes for a 3-pole device. 60
10 Connections ront connection via vertical connection adapters fitted with bare cable connectors. E2A E228A E189A 50 E229A E2230A detail 5 Ø 5 Ø11 193,5 ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer 61
11 Dimensions and connection W08 to W32 circuit breakers ixed 3/4-pole device Dimensions E46050A 189 (3P) 304 (4P) E46055A (3P) 3 (4P) 0 11 Mounting on base plate or rails Mounting detail E46051A E46052A Ø9, mini 60 maxi ,5 0 (3P) 3 (4P) 0 Ø9,5 Safety clearances Door cutout E59445A A (*) E46054A A (*) E46053A 295 mini (3P) 410 mini (4P) 295 mini 2 (1) 316 (2) 5 (1) 8 (2) 5 3 (1) 364 (2) 162,5 (1) 182 (2) : Datum. Insulated Metal Energised parts parts parts A (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. A(*) An overhead clearance of 110 mm is required to remove the arc chutes. An overhead clearance of mm is required to remove the terminal block. 62
12 MERLI GERI masterpact II Ue 690 (V) 50kA/1s Connections Horizontal rear connection Détail E46086A E46351A E46056A E46004A 08 HA10 Ui 1000V Uimp 12kV IEC9-2 50/60Hz E UTEVDE S CEI UEASMA E46087A Vertical rear connection E46089A 233, E46059A E46058A E46057A = = 3 Ø11,5 233,5 = = Ø11,5 detail ront connection E46088A E46090A E46060A 230,5 Top connection ottom connection 5 E ,5 3 Ø11,5 3 Ø11,5 219 detail ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer 63
13 Dimensions and connection W08 to W32 circuit breakers Drawout 3/4-pole device Dimensions E46506A 400 mini E46352A 2,5 (3P) 335,5 (4P) ,5 56 (*) 238,5 0, mini , (*) Disconnected position Mounting on base plate or rails Mounting detail E46354A E Ø11,5 x Ø11, Ø10, ,5 (3P) 282,5 (4P) 162,5 Safety clearances Door cutout E59446A A E46356A A E46355A 300 mini (3P) 4 mini (4P) 300 mini 2 (1) 379 (2) 5 (1) 222 (2) 3,3 (1) : Datum. Insulated Metal Energised parts parts parts A (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. A(*) An overhead clearance of 110 mm is required to remove the arc chutes. 3 (1) 364 (2) 162,5 (1) 182 (2) (1)
14 MERLI GERI masterpact II 08 HA10 Ui 1000V Uimp12kV Ue (V) kA/1s IEC9-2 50/60Hz E UTEVDESCEIUEASMA E46005A Connections Horizontal rear connection E46357A E46360A E46363A E46057A = = 3 Ø11,5 298,5 Vertical rear connection E46358A E46361A E46364A E46059A = = ,5 3 Ø11,5 detail ront connection E46359A E46362A E46365A E46819 Top connection 76 ottom connection Ø11,5 3 Ø11,5 284 ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer detail 65
15 Dimensions and connection W40 circuit breakers ixed 3/4-pole device Dimensions E46050A 189 (3P) 304 (4P) E46055A (3P) 3 (4P) 0 11 Mounting on base plate or rails Mounting detail E46051A E46052A Ø9, mini 60 maxi ,5 0 (3P) 3 (4P) 0 Ø9,5 Safety clearances Door cutout E59445A A (*) E46054A A (*) E46053A 295 mini (3P) 410 mini (4P) 295 mini 2 (1) 316 (2) 5 (1) 8 (2) 5 3 (1) 364 (2) 162,5 (1) 182 (2) : Datum. Insulated Metal Energised parts parts parts A (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. A(*) An overhead clearance of 110 mm is required to remove the arc chutes. An overhead clearance of mm is required to remove the terminal block. 66
16 MERLI GERI masterpact II Ue 690 (V) 50kA/1s E46484A 08 HA10 Ui 1000V Uimp 12kV IEC9-2 50/60Hz E UTEVDESCEI UEASMA Connections Horizontal rear connection E46485A E46351A ,5 E , ,5 17,5 52,5 E46490A 5 4 Ø11,5 332,5 (4P) 217,5 E46550A 100 Vertical rear connection E46486A E46488A 117,5 190,5 233,5 E46058A E46491A 1 ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer 5 Ø11,5 67
17 Dimensions and connection W40 circuit breakers Drawout 3/4-pole device Dimensions E46506A 400 mini E46352A 2,5 (3P) 335,5 (4P) ,5 56 (*) 238,5 0, mini , (*) Disconnected position Mounting on base plate or rails Mounting detail E46354A E Ø11,5 x Ø11, Ø10,5 167,5 (3P) 282,5 (4P) 162,5 Safety clearances Door cutout E59446A A E46356A A E46355A 300 mini (3P) 4 mini (4P) 300 mini 2 (1) 379 (2) 5 (1) 222 (2) 3,3 (1) : Datum. Insulated Metal Energised parts parts parts A (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. The safety clearances take into account the space required to remove the arc chutes. 3 (1) 364 (2) 162,5 (1) 182 (2) (1)
18 MERLI GERI masterpact II 08 HA10 Ui 1000V Uimp12kV Ue (V) kA/1s IEC9-2 50/60Hz E UTEVDESCEIUEASMA E46005A Connections Horizontal rear connection E46360A E46492A ,5 E ,5 0 17, ,5 52,5 E46490A 5 4 Ø11,5 332,5 217,5 E46550A 100 Vertical rear connection E46493A E46495A 117,5 E46491A 1 5 Ø11,5 190,5 detail 298,5 E46364A ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer 69
19 Dimensions and connection W40b to W63 circuit breakers ixed 3/4-pole device Dimensions E46282A 534 3P) 764 (4P) E46055A (3P) 775 (4P) 0 11 Mounting on base plate or rails Mounting detail E46284A E46283A Ø9, mini 60 maxi ,5 545 (6P) 775 (8P) 0 Ø9,5 Safety clearances Door cutout E59445A A (*) E46286A A (*) 639 mini (3P) 839 mini (4P) 295 mini E46285A 2 (1) 316 (2) 5 (1) 8 (2) 5 3 (1) 364 (2) 162,5 (1) 182 (2) : Datum Insulated Metal Energised parts parts parts A (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. A(*) An overhead clearance of 110 mm is required to remove the arc chutes. An overhead clearance of mm is required to remove the terminal block.
20 MERLI GERI masterpact II Ue HA (V) Icw 85kA/1s IEC9-2 50/60Hz E UTEVDESCEIUEASMA E46281A Ui 1000V Uimp 12kV Connections Horizontal rear connection (W40b - W50) E46551A E46289A E46287A 0 3, E46057A = = 3 Ø11,5 Prises arrière verticales (W40b - W50) Détail E46288A E46552A 68 E46290A ,5 141 E46059A = 76 = 38 3 Ø11,5 detail Vertical rear connection (W63) E59535A E59536A 117,5 E46290A ,5 3,5 E46491A 1 ote: Recommended connection screws: M10 s/s class A4 80 Tightening torque: 50 m with contact washer. detail 5 Ø11,5 71
21 Dimensions and connection W40b to W63 circuit breakers Drawout 3/4-pole device Dimensions E46487A 400 mini E46498A 565,5 (3P) 795,5 (4P) ,5 56 (*) 238,5 0, mini ,5 (*) Disconnected position Mounting on base plate or rails Mounting detail E46508A E46499A Ø11 x 34 3 (3P) 450 (4P) 174 (3P) 287,5 (4P) 1 (3P) 162,5 (4P) Safety clearances Door cutout E59446A A E46501A A 646 mini (3P) 876 mini (4P) 300 mini E46500A 2 (1) 379 (2) 5 (1) 222 (2) 3,3 (1) 0 5 : Datum. Insulated Metal Energised parts parts parts A (1) 364 (2) (1) Without escutcheon (2) With escutcheon ote: and are the symmetry planes for a 3-pole device. 162,5 (1) 182 (2) (1) 72
22 MERLI GERI masterpact II 08 HA10 Ui 1000V Uimp12kV Ue (V) kA/1s IEC9-2 50/60Hz E UTEVDESCEIUEASMA E46497A Connections Horizontal rear connection (W40b - W50) E46507A E46502A E46504A E46057A = = 348,5 3 Ø11,5 Vertical rear connection (W40b - W50) E46503A E46494A 68 E46505A 141 E46059A 348,5 = 76 = 38 3 Ø11,5 detail Vertical rear connection (W63) E59533A E59534A E46505A 117,5 190,5 E46491A 348,5 1 ote: Recommended connection screws: M10 s/s class A4 80 Tightening torque: 50 m with contact washer detail 5 Ø11,5 73
23 Dimensions and connection T/W accessories Mounting on backplate with special brackets ( W08 to W32 fixed). E46805A 429 (3P) 544 (4P) E46806A 4 Ø ,5 4, (3P) 522 (4P) 3,5 11 Disconnectable front-connection adapter ( W08 to W32 fixed) Horizontal rear connection E46807A E46809A 67 E46812A 183 E46057A = = Ø11,5 3,5 Vertical rear connection E46808A E46810A 67 E46811A 231 E46059A 2 = = ote: Recommended connection screws: M10 class 8.8 Tightening torque: 50 m with contact washer Datum 3,5 3 Ø11,5 detail 74
24 Rear panel cutout (drawout devices) W08 to W40 E462A E461A ,5 401 (3P) 516 (4P) W40b to W63 0,5 (3P) 3,5 (4P) 264 E464A E463A ,5 679 (3P) 909 (4P) 8,5 (3P) 8,5 (4P) 314 Escutcheon T ixed device E59885A Drawout device E59887A W ixed device E59890A E59889A Drawout device Datum
25 Dimensions and connection T/W external modules Connection of auxiliary wiring to terminal block E683A S : 0,6 mm 2 E684A S : 2,5 mm Ø3,5 One conductor only per connection point M6C relay module 99 E688A M6c S1 S2 24V 0V com. S3 S4 S5 S S1 S2 S3 S4 S5 S E689A M6c S1 S2 24V 0V com. S3 S4 S5 S S1 S2 S3 S4 S5 S6 46 External power supply module (AD) E690A 60 2 Ø6 L3 AD 2A Input 24VDC G1 Output 24VDC L4 + G E691A AD 2A L3 G1 Input 24VDC Output 24VDC + G2 L4 attery module (AT) Mounting 60 2 Ø6 E692A H3 Input 24VDC H AT 24V + Output H2 24VDC H E693A AT 24V H3 H2 Input 24VDC + Output 24VDC H4 + H1 76
26 Delay unit for M release MR 57 2 Ø4,2 E694A A A A A , M UVR 100/0V AC/DC S Retardateur de M Time delay for UVR E695A M UVR 100/0 V AC/DC 1012 S Retardateur de M Time delay for UVR Craddle communication module ModUS atius CT CCM modbus CD ault Com. Address sync. CE Réseau shield Disjoncteur + etwork reaker External sensor for source ground return (SGR) protection Sensor MGD summer module E58561 E687A E685A E686A MDG
27 Dimensions and connection T/W external modules External sensor for external neutral Dimensions 400/1600 A (T06 to T16) 400/00 A (W08 to W) 4 Ø14 4 Ø14 E699 H1 GD V VC 2 1 SG2 SG H E0 H1 SG1 SG2 1 2 GD V VC H /4000 A (W0 to W40) 00/6300 A (W40b to W63) 8 Ø14 16 Ø14 E1 H1 SG1 SG2 1 2 GD V VC H E2 H1 SG1 SG2 1 2 GD V VC H H1 SG1 SG2 1 2 GD V VC H Installation 400/1600 A (T06 to T16) 400/00 A (W08 to W) E697A E /4000 A (W to W40) 00/6300 A (W40b to W63) E696A E identical external sensor shipped as loosed part 78
28 Rectangular sensor for earth leakage protection (Vigi) 280 x mm window 4 Ø9 E3A M1 M2 M3 E M1 M2 M x 160 mm window 8 Ø9 E717A E M1 M2 M3 M1 M2 M usbars I i 1600 A I i 30 A window (mm) 280 x 4 x 160 weight (kg) usbars path 280 x window usbars spaced mm centre-to-centre 4 x 160 window usbars spaced mm centre-to-centr E679 E7 E8 M1 M2 M3 2 bars 50 x 10 M1 M2 M3 4 bars 100 x 5 E67971 M1 M2 M3 2 bars 100 x 5 M1 M2 M3 4 bars 1 x 5 79
Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationLV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity
LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationMasterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A
Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationLow voltage electrical distribution. Compact NS. Circuit breakers and switch-disconnectors from 630 to 1600 A. User manual 10/2017
Low voltage electrical distribution Compact NS Circuit breakers and switch-disconnectors from 630 to 1600 A User manual 10/2017 User manual for circuit breakers and switch-disconnectors Compact NS630b-1600
More informationMasterpact NT and NW LV power circuit breakers and switch-disconnectors
Low oltage Masterpact NT and NW LV power circuit reakers and switch-disconnectors Catalogue 2009 Presentation Masterpact NT and NW The standard for power circuit reakers around the world. Oer the years,
More informationMiniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures
.2....6 special versions High performance range H for 000V/AC Circuit breaker for 7V/DC DC circuit breaker up to 0V/DC Miniature circuit breakers A.7.8.0 Technical data Economy range N, V/AC Standard range
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationCDW9 Air Circuit Breaker
Main Characteristics rame():1600, 4000H1, 4000H2, 6300L In ():630 ~ 6300 Ue (V):400/4, 690 Poles: 3P & 4P Type: fixed type & draw-out type Certificates: CE KEM Standards:IEC 60947-2 Intelligent Control
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationCircuit protection and control devices 0.5 to 6300 A
Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access
More informationCompact NS. Installation recommendations
Compact NS Installation recommendations Presentation 6 Functions and characteristics Operating conditions 144 Installation in switchboards 145 Power supply and weights 145 Safety clearances and minimum
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationCompact Merlin Gerin 80 to 3200 A
LV power air circuit breakers and switch-disconnectors Catalogue Compact Merlin Gerin 80 to 3200 A 2005 Industries SA 5, rue Nadar 92506 Rueil-Malmaison Cedex France Tel : +33 (0)1 41 29 82 00 Fax : +33
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage
Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144
More informationEssential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.
The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.
More informationLow voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue
Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationHDW9 Air Circuit Breaker
Main Characteristics rame():1600n, 4000H1, 4000H2, 6300L In ():630 ~ 6300 Ue (V):400/4, 690 Poles: 3P & 4P Type: fixed type & draw-out type Certificates: CE KEM Standards:IEC 60947-2 Intelligent Control
More informationCompact NSX100 to 630
Low Voltage Compact NSX00 to 30 Circuit reakers and switch-disconnectors Sustitution guide - Technical characteristics 200 Sustitution guide Technical characteristics Performance levels and trip units
More informationPrisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter
3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice
More informationTECHNICAL DESCRIPTION
DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and
More informationCABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More informationC1251N DC and C1251N 1000 V
T I Catalogue numbers C25N DC and C25N 000 V E2409 Compact C25N DC with magnetic trip unit (complete device - fixed/fc) Compact C25N DC P2 46034 P4 46036 C25N 000 V basic frame (separate components - fixed/fc)
More informationMasterpact NW DC Circuit Breakers
Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................
More informationMANUALLY OPERATED CHANGEOVER SWITCHES
are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,
More informationLow Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011
Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationCircuit protection and control devices 0.5 to 6300 A
Electrical distriution LV product characteristics Circuit protection and control devices 0.5 to 6300 A Overview of solutions Main power distriution oard for commercial applications Main power distriution
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationOSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage
Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationLow voltage. EasyPact EZC. Moulded-case circuit breakers from 15 to 630 A. Catalogue 2013
Low voltage EasyPact EZC Moulded-case circuit breakers from 15 to 630 A Catalogue 2013 EasyPact EZC General contents Presentation 2 Functions and characteristics A-1 Busbars B-1 Installation guide C-1
More informationThe need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted
110 The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.
More informationMasterpact NW DC Circuit Breakers
Masterpact NW DC Circuit Breakers Catalog 0613CT0501R1/07 2007 Class 0613DC CONTENTS Description..............................................Page Contents General Information Line 1.........................................
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics
More informationSpectronic-SP Air Circuit Breaker
Spectronic- Air Circuit Breaker Circuit Breakers 800 to 2500A Series Rated Short circuit breaking capacity : lcs 50 to 55KA ( 4 15V) Complete range Fixed with manual control 3 or 4 poles Electrical control
More informationATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A
TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS
More informationMemshield - ACB Ratings & Specifications
Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY
More informationMagnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data
Effective May 2003 Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data Magnum IEC Air Circuit Breaker Product Family The New Magnum Narrow Frame Drawout Breaker and Cassette TD030003E
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationACB/ATS Air Circuit Breaker / Automatic Transfer Switch
ACB/ATS Air Circuit Breaker / Automatic Transfer Switch ACB/ATS Air Circuit Breaker / Automatic Transfer Switch CREATING VALUE 02_03 No matter where you are in the world or in which industrial field, Daeryuk
More informationC60H-DC C curve. Catalogue numbers
distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More informationMOULDED CASE CIRCUIT BREAKERS 16A TO 630A
TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions*
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationInstallation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue
FAQs I have installed the ATS panel but it won t go into the mains supply? First check all cables are in place and properly installed and that the control fuses (A-C on page 4) have not blown. If it still
More informationsirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed
site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on
More informationMagnum IEC Low Voltage Air Circuit Breakers
Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationCable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.
Transportation and storage.. 3 General. 3 Unpacking at installation site....... 3 Transfer of cubicles at installation site... 3 Weight.. 4 Temporary storage. 4 Erection at site 5 General. 5 The switchgear
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V
Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics
More informationSpectronic SP Air Circuit Breaker. Protecting people, property & productivity
Protecting people, property & productivity Circuit Breakers 800 to 2500A Series SP Rated short circuit breaking capacity : lcs 50 / 55KA ( 415V) Complete range Fixed with manual control 3 or 4 Poles The
More informationMagnetic Overcurrent Circuit Breaker
Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A
Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection
More informationModular contactor for installation into distribution boards
Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,
More informationImportant Safety Notice
Technical Data: MCC-0 (S0-SCJ) IPX Enclosed MCCs Imptant Safety otice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of
More informationMoulded Case Circuit Breakers
Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field
More informationFuse switch disconnectors
SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED
More informationBREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker
BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to
More informationUTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB
PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L
More informationCircuit protection and control devices. 0.5 to 6300 A. LV product characteristics
Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2006 This international site allows you to access all the Merlin Gerin products in just 2 clicks via comprehensive range
More informationTechnical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :
55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationSpectronic SP Air Circuit Breaker. Protecting people, property & productivity
Spectronic SP Air Circuit Breaker Protecting people, property & productivity Spectronic SP Air Circuit Breaker Circuit Breakers 800 to 2500A Series SP Rated short circuit breaking capacity : lcs 50 / 55KA
More information