1 Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2006

2 This international site allows you to access all the Merlin Gerin products in just 2 clicks via comprehensive range data-sheets, with direct links to: complete lirary: technical documents, catalogs, FAQs, rochures selection guides from the e-catalog. product discovery sites and their Flash animations. You will also find illustrated overviews, news to which you can suscrie, the list of country contacts According to IEC This guide, part of the Guiding System, is the essential tool to "guide" you any time in your usiness: design office, consultant contractor, paneluilder teacher, trainer. Comprehensive and concrete information on: all the new technical solutions all the components of an installation from a gloal point of view all the IEC standards modifications all the fundamental electrotechnical knowledge all the design stages, from medium to low voltage.

3 Circuit protection and control devices Contents Multi 9 Multi 9 circuit reakers from 0.5 to 125 A 6 NG160 Characteristics of NG160 circuit reakers and switch-disconnectors 8 EasyPact EasyPact circuit reakers from 15 to 250 A 10 Compact NS Compact NS AC circuit reakers up to 630 A 14 Compact NS AC circuit reakers from 630 up to 3200 A 16 Compact NS DC circuit-reakers from 100 to 630 A 18 Masterpact NT and NW Masterpact NT06 to NT16 AC circuit reakers and switch-disconnectors from 630 to 1600 A 20 Masterpact NW08 to NW63 AC circuit reakers and switch-disconnectors from 800 to 6300 A 22 Masterpact NW10 to NW40 DC circuit reakers from 800 to 6300 A 24 Micrologic control units - Overview of functions 26 Interpact INS Interpact INS40 to 160 switch-disconnectors 28 Interpact INS to 630 switch-disconnectors 32 Interpact INS630 to 2500 switch-disconnector 36 Interpact INV Interpact INV100 to 630 switch-disconnectors 40 Interpact INV630 to 2500 switch-disconnectors 44 Manual source-changeover sytems Interpact INS and Compact NS 40 A to 630 A 48 Compact NS and Masterpact NT/NW 630 A to 6300 A 49 Remote-operated source-changeover systems Compact NS100/ A to 1600 A 50 Masterpact NT/NW 630 A to 6300 A 51 Fupact Fupact INF.32 to INF.800 switch-disconnector fuse 52 Fupact ISFT100 to ISFT630 fuse-switch disconnectors 56 Fupact ISFL160 to ISFL630 fuse-switch disconnectors 60 Vigirex Protection and monitoring relays 64 1

4 The Guiding System, the new way to create your electrical installations 0 A comprehensive offer of products with consistent design The Guiding System is first and foremost a Merlin Gerin product offer covering all electrical distriution needs. However, what makes all the difference is that these products have een designed to operate togheter: mechanical and electrical compatiility, interoperaility, modularity, communication. Thus the electrical installation is oth optimised and more efficient: etter continuity of supply, enhanced safety for people and equipment, guaranteed upgradeaility, effective monitoring and control. Tools to simplify design and implementation With the Guiding System, you have a comprehensive range of tools - the Guiding Tools - that will help you increase your product knowledge and product utilisation. Of course this is in compliance with current standards and procedures. These tools include technical ooklets and guides, design aid software, training courses, etc. and are regularly updated. For a genuine partnership with you Because each electrical installation is unique, there is no standard solution. With the Guiding System, the variety of cominations allows for genuine customisation solutions. You can create and implement electrical installations to meet your creative requirements and design knowledge. You and Merlin Gerin s Guiding System form a genuine partnership. For more details on the Guiding System, consult 2

5 A consistent design of offers from Medium Voltage to Low Voltage All Merlin Gerin offers are designed according to electrical, mechanical and communication consistency rules. The products express this consistency y their overall design and shared ergonomics. 0 Electrical consistency: Discrimination guarantees co-ordination etween the operating characteristics of serial-connected circuit-reakers. Should a fault occurs downstream, only the circuit-reaker placed immediately upstream from the fault will trip. Each product complies with or enhances system performance at coordination level: reaking capacity, Isc, temperature rise, etc. for more safety, continuity of supply (discrimination) or economic optimisation (cascading). The leading edge technologies employed in Merlin Gerin s Guiding System ensure high performance levels in discrimination and cascading of protection devices, electrodynamic withstand of switches and current distriutors, heat loss of devices, distriution locks and enclosures. Likewise, inter-product ElectroMagnetic Compatiilty (EMC) is guaranteed. Mechanical consistency: Each product adopts dimensional standards simplifying and optimising its use within the system. It shares the same accessories and auxiliaries and complies with gloal ergonomic choices (utilisation mode, operating mode, setting and configuration devices, tools, etc.) making its installation and operation within the system a simpler process. Direct connection of the Canalis KT usar trunking on the Masterpact 3200 A circuit reaker. Communication consistency: Thanks to the use of standard We technologies, you can offer your customers intelligent Merlin Gerin switchoards allowing easy access to information: follow-up of currents, voltages, powers, consumption history, etc. Each product complies with gloal choices in terms of communication protocols (Modus, Ethernet, etc.) for simplified integration in the management, supervision and monitoring systems. Guiding Tools for more efficient design and implementation of your installations. 3

6 0 SM6 Medium voltage switchoard system from 1 to 36 kv Sepam Protection relays Masterpact Protection switchgear from 100 to 6300 A Trihal MV/LV dry cast resin transformer from 160 to 5000 kva Evolis MV vacuum switchgear and components from 1 to 24 kv. The Technical guide These technical guides help you comply with installation standards and rules i.e.: The electrical installation guide, the protection guide, the switchoard implementation guide, the technical ooklets and the co-ordination tales all form genuine reference tools for the design of highperformance electrical installations. For example, the LV protection co-ordination guide - discrimination and cascading - optimises choice of protection and connection devices while also increasing markedly continuity of supply in the installations. CAD software and tools The CAD software and tools enhance productivity and safety. They help you create your installations y simplifying product choice through easy rowsing in the Guiding System offers. Last ut not least, they optimise use of our products while also complying with standards and proper procedures. 4

7 0 Compact Protection switchgear system from 100 to 630 A Multi 9 Modular protection switchgear system up to 125 A Prisma Plus Functional system for electrical distriution switchoards up to 3200 A Pragma Enclosures for distriution switchoards up to 160 A Canalis Prefaricated Busar Trunking from 25 to 4000 A PowerLogic Power management Training Training allows you to acquire the Merlin Gerin expertise (installation design, work with power on, etc.) for increased efficiency and a guarantee of improved customer service. The training catalogue includes eginner s courses in electrical distriution, knowledge of MV and LV switchgear, operation and maintenance of installations, design of LV installations to give ut a few examples. merlin-gerin.com This international site allows you to access all the Merlin Gerin products in just 2 clicks via comprehensive range data-sheets, with direct links to: complete lirary: technical documents, catalogs, FAQs, rochures selection guides from the e-catalog product discovery sites and their Flash animations. You will also find illustrated overviews, news to which you can suscrie, the list of country contacts 5

8 Multi 9 Multi 9 circuit reakers from 0.5 to 125 A NR_ R_21 PB100270_ NR_14 DPN Vigi C60 C120 NG125 Multi 9 circuit reakers Numer of poles 1 + N Electrical characteristics Rated current (A) In 4-40 Rated insulation voltage (V) Ui 300 Impulse withstand voltage (kv) Uimp 4 Maximum operational voltage (V) Ue AC 50/60 Hz 230 Fast closing Suitaility for isolation and positive contact indication AC reaking capacity (ka rms) IEC (EN 60898) Icn 230/400 V 6 IEC (EN ) Icu 130 V V V V V V - Ics (% of Icu) - Trip units (non adjustale) Curve type B (lm = 3 to 5 ln) C (lm = 5 to 10 ln) D (lm = 10 to 14 ln) - K (lm = 10 to 14 In) - Z (lm = 2.4 to 3.2) - MA (lm = 12 ln) - Earth leakage protection Add-on rcd's (Vigi module) - Integrated Sensitivity type (ma) a AC A 30 k A si A si E - Electrical auxiliaries Auxiliary and alarm switches (OF-SD) Shunt trip (MX); undervoltage release (MN) Emergency stop opening switch (MNx) Voltage threshold release (MSU) Connection Cale maxi capacity (mm 2 ) Flexile 10 Rigid 16 Installation Plug in ase - Terminal shieds - Padlocking device Rotary handle - Dimensions (mm) W 36 H 81 D 70 DPN N Vigi 6

9 Multi 9 C60N C60H C60L C120N C120H NG125N NG125H NG125L % 50 % 50 % 50 % 50 % 75 % 50 % 75 % 75 % 75 % y 40 A (y 25 A) 25 (> 25 A) (y 63 A) 50 (> 63 A) 25 (y 25 A) 35 (> 25 A) (y 63 A) 70 (> 63 A) y 63 A y 63 A per pole 18 per pole 18 per pole 18 per pole 18 per pole 27 per pole 27 per pole 27 per pole 27 per pole 27 per pole

10 NG160 Characteristics of NG160 circuit reakers and switch-disconnectors 0 Incomer for modular switchoards PB and 4 pole circuit reakers and switchdisconnectors specially designed for use upstream of Multi 9 modular devices: reinforcement of reaking capacities of downstream devices y cascading up to 25 ka easy installation in Pragma or Prisma Plus type G enclosures: v standard 45 mm front cut-out v clip-on installation on a DIN rail v reduced depth (82.5 mm). NG160 circuit reaker. NG160 circuit reaker Electrical characteristics as per IEC Rated current (A) In 40 C 160 Rated insulation voltage (V) Ui 800 Rated impulse withstand voltage Uimp 8 (kv) Rated operational voltage (V) Ue AC 50/60 Hz 500 Type of circuit reaker E N H Ultimate reaking capacity Icu AC 220/240 V (ka rms) 50/60 380/415 V Hz 440 V V Service reaking capacity Ics % Icu 75 % Suitaility for isolation Duraility (C-O cycles) mechanical electrical (In -440 V) 5000 Protection Built-in thermal-magnetic trip unit Ratings In Thermal protection Ir fixed threshold adjustale threshold 0.8 to 1 In Magnetic protection lm NG160NA switch-disconnector Electrical characteristics as per IEC Conventional thermal current (A) Ith 40 C 160 Rated insulation voltage (V) Ui 800 Rated impulse withstand voltage Uimp 8 (kv) Rated operational voltage (V) Ue AC 50/60 Hz 500 Rated operational current Ie AC 50/60 Hz AC22A AC23A 220/240 V /415 V /480 V V Short-circuit lcm (ka peak) 2.1 making capacity min. for switchdisconnector alone max. with protection y upstream circuit reaker 330 Short-time withstand current Icw (A rms) 1 s s 1500 Suitaility for isolation Coordination etween circuit reakers and switch-disconnectors The switch-disconnector must e protected against downstream short-circuits. The choice of the right switch-disconnector therefore depends on coordination with the protective device installed upstream. The tale elow indicates the maximum short-circuit current in karms for which the switch-disconnector is protected y coordination with the circuit reaker located upstream. Important: the switch-disconnector must e protected against overloads. The rating of the switch-disconnector must e greater than or equal to that of the upstream circuit reaker. Upstream protection NR100F NS100 - NS160 NR160F N SX H NG160NA downstream V Isc max ka rms Making capacity ka peak V Isc max ka rms Making capacity ka peak

11 NG160 PD Installation and connections Connections Connectors Bare cales from 1.5 to 70 mm² cales Dimensions (mm) W x H x D Width in 9 mm modules NG160 3P 90 x 120 x P 120 x 120 x NG160 3P 210 x 120 x with Vigi 4P 240 x 120 x Weight (kg) Device 3P 1.1 4P 1.4 Device + Vigi 3P 2.6 module 4P 2.9 NG160 in modular enclosure. 9

12 EasyPact Characteristics 0 PB EasyPact circuit reakers Numer of poles Rated current (A) In at 40 C PB PB EZC100 1P EZC100 2P EZC100 3P Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Electrical characteristics as per IEC , EN , JIS Ultimate reaking capacity (ka rms) Icu AC 50/60 Hz 110/130 V 220/230/240 V 380 V 400/415 V 440 V 550 V DC 125 V (1P) 250 V (2P in series) Rated service reaking capacity Ics % Icu V V Suitaility for isolation Utilisation category Pollution degree Endurance (C-O cycles) Mechanical Electrical In/415 V Electrical characteristics as per NEMA-AB1 Breaking capacity (ka) HIC AC 50/60 Hz 240 V 277/480 V Protection Overload protection Bimetal Instantaneous protection Magnetic Auxiliaries Indication contacts Auxiliary switch AX Alarm switch AL Comined AX + AL AXAL Voltage releases Shunt trip release SHT Undervoltage release UVR Installation Connection Crimp lugs/ars Accessories Box lugs for are cales Rotary handles direct extended Terminal extensions Spreaders Phase arriers Terminal shields Padlocking system DIN rail plate Dimension and weight Dimensions (mm) D x H W Weight (kg) 10

13 EasyPact 0 EZC100B EZC100F EZC100N EZC100H , 16, 20, 25, 30, 32, 40, 45, 50, 60, 63 15, 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, , 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, , 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, , 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, , 16, 20, 25, 30, 32, 40, 45, 50, 60, 63, 75, 80, (1) % 50 % 50 % 50 % 50 % 50 % 25 % 50 % 50 % 50 % 50 % 25 % A A A A A A (2) (2) 18 (3) fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed (3) - - (3) (3) 60 x x x x x x (2P), 75 (3P) (2P), 0.78(3P) (1) 50 ka for 2 poles. (2) For 277 V only. (3) For 3 poles only. 11

14 EasyPact Characteristics 0 PB EasyPact circuit reakers Numer of poles Rated current (A) In 40 C PB EZC250 3P EZCV250 4P EZC400 3P Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Electrical characteristics as per IEC and EN Electrical characteristics as per JIS C / Ultimate reaking capacity (ka rms) Icu AC 50/60 Hz 110/130 V 220/230/240 V 380 V 400/415 V 440 V 550 V DC 125 V (1P) 250 V (2P in series) Rated service reaking capacity (ka rms) Ics % Icu Suitaility for isolation Utilisation category Pollution degree Endurance (C-O cycles) Mechanical Electrical In / 415 V Electrical characteristics as per NEMA-AB1 Breaking capacity (ka) HIC AC 50/60 Hz 240 V 277/480 V Protection Overload protection Bimetal Instantaneous protection Magnetic fixed (+ 20 %) Earth-leakage protection Adjustale Sensitivities I n (ma) Time-delay (s) Max reaking time (s) Auxiliaries Indication contacts Auxiliary switch AX Alarm switch AL Comined AX + AL AXAL Earth- Alarm switch ALV Voltage releases Shunt trip release SHT Undervoltage release UVR Installation Connection Crimp lugs / ars Accessories Dimension and weight Dimensions (mm) Box lugs for are cales Rotary handles Terminal extensions Spreaders Phase arriers Terminal shields Rear connections Padlocking system D x H W Direct Extended Weight (kg) 12

15 EasyPact 0 EZC250F EZC250N EZC250H EZCV250N EZCV250H EZC400N EZC400H , 125, 150, 160, 175, 200, 225, , 125, 150, 160, 175, 200, 225, , 80, 100, 125, 150, 160, 175, 200, 225, , 125, 150, 160, 175, 200, 225, , 80, 100, 125, 150, 160, 175, 200, 225, , 80, 100, 125, 150, 160, 175, 200, 225, , 80, 100, 125, 150, 160, 175, 200, 225, , 300, 350, , 300, 350, % 50 % 50 % 50 % 50 % 50 % 50 % 50 % 50 % A A A A A A A A A (1) fixed fixed fixed fixed fixed fixed fixed fixed fixed 10 In 10 In 10 In 10 In 10 In 10 In 10 In 10 In 10 In /300/500/ /300/500/ /0.2/0.5/1 0/0.2/0.5/ /0.4/1/2 0.15/0.4/1/ x x x x x x x x x (3P) 140 (4P) (2P) 1.3 (3P) (3P) 2.1 (4P) 105 (3P) 140 (4P) 1.6 (3P) 2.1 (4P) 140 (3P) 185 (4P) 5 (3P) 7.5 (4P) 140 (3P) 185 (4P) 5 (3P) 7.5 (4P) (1) For 3 poles only. 13

16 Compact NS Compact NS AC circuit reakers up to 630 A PB101050_33 PB101044_42 Compact NS250H Compact NS630N (1) 2P in 3P case for type N only (2) specific trip units are availale for operational voltages > 525 V (3) NS100N et U u 500 V: Ics = 50 % Icu (4) operational voltage y 500 V Compact circuit reakers Numer of poles Control manual toggle direct or extended rotary handle electric Connections fixed front connection rear connection plug-in (on ase) front connection rear connection withdrawale (on chassis) front connection rear connection Electrical characteristics as per IEC and EN Rated current (A) In 40 C 65 C Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Type of circuit reaker Ultimate reaking capacity (ka rms) lcu AC 220/240 V 50/60 Hz 380/415 V 440 V 500 V 525 V 660/690 V Service reaking capacity (ka rms) lcs % Icu Suitaility for isolation Utilisation category Duraility (C-O cycles) Electrical characteristics as per NEMA AB1 (H.I.C.) Breaking capacity (ka) Electrical characteristics as per UL508 Breaking capacity (ka) mechanical electrical 440 V In/2 In 240 V 480 V 600 V 240 V 480 V 600 V Protection Trip units Overload protection long time Ir (In x ) Short-circuit protection short time lsd (Ir x ) instantaneous Ii (In x ) Earth-fault protection lg (In x ) Zone selective interlocking ZSI Add-on earth-leakage protection add-on Vigi module comination with Vigirex relay Current measurements Additional measurement, indication and control auxiliaries Indication contacts MX shunt and MN undervoltage releases Voltage-presence indicator Current-transformer module and ammeter module Insulation-monitoring module Remote communication y us Device-status indication Device remote operation Transmission of settings Indication and identification of protection devices and alarms Transmission of measured current values Installation Accessories terminal extensions and spreaders terminal shields and interphase arriers escutcheons Dimensions (mm) W x H x D fixed, front connections 2-3P / 4P Weight (kg) fixed, front connections 3P / 4P Source changeover system (see section on source changeover systems) Manual, remote-operated and automatic source changeover systems 14

17 Compact NS NS100 NS160 NS250 NS400 NS630 2 (1), 3, 4 2 (1), 3, 4 2 (1), 3, 4 3, 4 3, N SX H L N SX H L N SX H L N H L N H L (2) 20 (2) 75 (2) 10 (2) 20 (2) 35 (2) 100 % (3) 100 % 100 % 100 % 100 % (4) A A A A A N SX H L N SX H L N SX H L N H L N H L N SX H L N SX H L N SX H L N H L N H L TM (thermal-magnetic) STR22 (electronic) STR23 (electronic) STR53 (electronic) x 161 x 86 / 140 x 161 x x 255 x 110 / 185 x 255 x to 2.2 / 2.6 to to

18 Compact NS Compact NS AC circuit reakers from 630 to 3200 A PB101669R_38 E45178R_68 Compact NS800L Compact NS2000H (1) 65 C with vertical connections. See the temperature derating tales for other types of connections. (2) Ics: 100 % Icu for reaking capacity 440V/500V/660V Ics: 75 % Icu for reaking capacity 220V/380V. Compact circuit reakers Numer of poles Control manual toggle direct or extended rotary handle electric Type of circuit reaker Connections fixed front connection rear connection front connection with are cales withdrawale (on chassis) front connection rear connection Electrical characteristics as per IEC and EN Rated current (A) In 50 C 65 C (1) Rated insulation voltage (V) Ui Rated impulse withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz Type of circuit reaker Ultimate reaking capacity (ka rms) lcu AC 220/240 V 50/60 Hz 380/415 V 440 V 500/525 V 660/690 V Service reaking capacity (ka rms) lcs Value or % Icu manual operation electrical operation Short-time withstand current (ka rms) lcw AC 50/60 Hz 1 s 3 s Integrated instantaneous protection ka peak ±10 % Suitaility for isolation Utilisation category Duraility (C-O cycles) Pollution degree Electrical characteristics as per Nema AB1 Breaking capacity at 60 Hz (ka) mechanical electrical 440 V In/2 In 690 V In/2 In 240 V 480 V 600 V Protection and measurements Interchangeale control units Overload protection long time Ir (In x ) Short-circuit protection short time Isd (Ir x ) instantaneous Ii (In x ) Earth-fault protection lg (In x ) Residual earth-leakage protection I n Zone selective interlocking ZSI Protection of the fourth pole Current measurements Remote communication y us Device-status indication Device remote operation Transmission of settings Indication and identification of protection devices and alarms Transmission of measured current values Additional indication and control auxiliaries Indication contacts Voltage releases MX shunt release/mn undervoltage release Installation Accessories Dimensions fixed devices, front connections (mm) H x W x D Weight fixed devices, front connections (kg) terminal extensions and spreaders terminal shields and interphase arriers escutcheons 3P 4P 3P 4P Source changeover system (see section on "source changeover systems") Manual, remote-operated and automatic source changeover systems 16

19 Compact NS NS630 NS800 NS1000 NS1250 NS1600 NS1600 NS2000 NS2500 NS3200 3, 4 3, 4 3, 4 3, 4 3, 4 - (except LB) - N H L LB N H L N H N H N H N H L LB N H L N H N H N H % 75 % 100 % 100 % 100 % 75 % 100 % 100 % 75 % 75 % 50 % 100 % (2) 75 % 75 % 50 % 100 % - 75 % 50 % 100 % 75 % 50 % 75 % 50 % 100 % (2) 75 % B B A A B B A B B B B B B III III III III III N H L LB N H L N H N H N H Micrologic 2.0 Micrologic 5.0 Micrologic 2.0 A Micrologic 5.0 A Micrologic 6.0 A Micrologic 7.0 A x 210 x x 420 x x 280 x x 535 x

20 Compact NS Compact NS DC circuit-reakers from 100 to 630 A 0 PB PB PB PB Compact circuit reaker Numer of poles Electrical characteristics as per IEC / and EN / Rated current at 40 C In (A) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kv peak) Rated operational voltage Ue (V DC) Type of circuit reaker Ultimate reaking capacity (L/R = 5 ms and L/R = 15 ms) Icu (ka rms) V DC V (1P) (1) Service reaking capacity Ics % Icu Rated making capacity Icm % Icu Utilisation category Breaking time (ms) Suitaility for isolation Pollution degree (as per IEC ) Protection against overcurrents (see "LV circuit reakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Protection Duraility (O/F cycles) Indication and control auxiliaries Auxiliary contacts Voltage release Installation and connections Fixed Plug-in (ase) Withdrawale (chassis) Dimensions and weight Dimensions H x W x D (mm) connected in series Weight (kg) connected in series Mechanical Electrical MX shunt release MN undervoltage release Fixed Fixed (1) Numer of poles taking part in current interruption. Example. The NS100N circuit reaker exists in the following versions: - 1 pole with an Icu of 50 ka, for systems y 250 V - 2 poles with an Icu of 85 ka, for systems y 500 V; 1 pole can e used in a 250 V system. 250 V (1P) (1) 500 V (2P) (1) 750 V (3P) (1) Built-in Interchangeale Overloads Short-circuits 250 V In 250 V In/2 500 V In 500 V In/2 750 V In 750 V In/2 Front connection Rear connection Front connection Rear connection Front connection Rear connection 1P 2P 3P 4P 1P 2P 3P 4P 18

21 Compact NS NS100 NS160 NS250 NS400 NS / /4 3/4 3/4 3/ N H N H DC N H N H DC DC DC DC % 100 % A < 10 ms III x 35 x x 35 x x 70 x x 70 x x 105 x x 105 x x 140 x x 140 x x 140 x x 185 x to to to to

22 Masterpact NT and NW Masterpact NT06 to NT16 AC circuit reakers and switch-disconnectors from 630 to 1600 A 0 PB Common characteristics Numer of poles 3/4 Rated insulation voltage (V) Ui 1000 Impulse withstand voltage (kv) Uimp 12 Rated operational voltage (V AC 50/60 Hz) Ue 690/1000 Suitaility for isolation IEC Degree of pollution IEC Basic sweatchgear Circuit-reaker as per IEC Rated current (A) In at 40 C/50 C (1) Rating of 4th pole (A) Sensor ratings (A) Type of circuit reaker Ultimate reaking capacity (ka rms) Icu 220/415 V V AC 50/60 Hz 440 V 525 V 690 V 1000 V Rated service reaking capacity (ka rms) Ics % Icu Utilisation category Rated short-time withstand current (ka rms) V AC 50/60 Hz Icw 0.5 s 1 s 3 s Integrated instantaneous protection (ka peak ±10 %) Rated making capacity (ka peak) Icm 220/415 V V AC 50/60 Hz 440 V 525 V 690 V 1000 V Break time (ms) etween tripping order and arc extinction Closing time (ms) Circuit-reaker as per NEMA AB1 Breaking capacity (ka) V AC 50/60 Hz 240 V 480 V 600 V (1) 50 C: rear vertical connected. Refer to temperature derating tales for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) SELLIM system. (4) Availale for 480 V NEMA. (5) Suitale for motor control (direct-on-line starting). Switch-disconnector as per IEC and Annex A Type of switch-disconnector Rated making capacity (ka peak) Icm 220 V AC23A/AC3 category V AC 50/60 Hz 440 V 525/690 V 1000 V Rated short-time withstand current (ka rms) Icw 0.5 s AC23A/AC3 category V AC 50/60 Hz 1 s 3 s Ultimate reaking capacity Icu (ka rms) with an external protection relay 690 V Maximum time delay: 350 ms Mechanical and electrical duraility as per IEC /3 at In/Ie Service life Mechanical without maintenance C/O cycles x 1000 Type of circuit reaker Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC V 1000 V Type of circuit reaker or switch-disconnector Rated operationnal current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC V Type of circuit reaker or switch-disconnector Rated operationnal current Ie (A) AC3 (5) Motor power 380/415 V (kw) 440 V (kw) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC Annex M/IEC V 20

23 Masterpact NT and NW Sensor selection Sensor rating (A) 250 (1) Ir threshold setting(a) 100 to to to to to to to 1600 (1) For circuit-reaker NT02, please consult us. NT06 NT08 NT10 NT12 NT to to to to to 1600 H1 H2 L1 (2) H10 H1 H2 H % 100 % B B A B B B B x In (3) < 50 < HA HA10 HA HA H1 H2 L1 H10 H1 H2 L1 H10 H1 H2 L1 H10 H1 H2 H10 H10 H1 H H1/H2/HA H1/H2/HA y to to to to 560 y to to to to

24 Masterpact NT and NW Masterpact NW08 to NW63 AC circuit reakers and switch-disconnectors from 800 to 6300 A 0 PB Common characteristics Numer of poles 3/4 Rated insulation voltage (V) Ui 1000/1250 Impulse withstand voltage (kv) Uimp 12 Rated operational voltage (V AC 50/60 Hz) Ue 690/1150 Suitaility for isolation IEC Degree of pollution IEC (1000 V) / 3 (1250 V) Basic circuit-reaker Circuit-reaker as per IEC Rated current (A) at 40 C / 50 C (1) Rating of 4th pole (A) Sensor ratings (A) PB Type of circuit reaker Ultimate reaking capacity (ka rms) V AC 50/60 Hz Rated service reaking capacity (ka rms) Ics % Icu Utilisation category Rated short-time withstand current (ka rms) V AC 50/60 Hz Icw 1 s 3 s Integrated instantaneous protection (ka peak ±10 %) Rated making capacity (ka peak) V AC 50/60 Hz Break time (ms) etween tripping order and arc extinction Closing time (ms) Circuit-reaker as per NEMA AB1 Breaking capacity (ka) V AC 50/60 Hz Icu Icm 220/415/440 V 525 V 690 V 1150 V 220/415/440 V 525 V 690 V 1150 V 240/480 V 600 V Unprotected circuit-reaker Tripping y shunt trip as per IEC Type of circuit reaker Ultimate reaking capacity (ka rms) V AC 50/60 Hz Icu V Rated service reaking capacity (ka rms) Ics % Icu Rated short-time withstand current (ka rms) Icw 1 s 3 s Overload and short-circuit protection External protection relay: short-circuit protection, maximum delay: 350 ms (4) Rated making capacity (ka peak) V AC 50/60 Hz Icm V (1) 50 C: rear vertical connected. Refer to temperature derating tales for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) Equipped with a trip unit with a making current of 90 ka peak. (4) External protection must comply with permissile thermal constraints of the circuit reaker (please consult us). No fault-trip indication y the SDE or the reset utton. (5) Availale for 480 V NEMA. (6) Suitale for motor control (direct-on-line starting). Switch-disconnector as per IEC and Annex A Type of switch-disconnector Rated making capacity (ka peak) AC23A/AC3 category V AC 50/60 Hz Rated short-time withstand current (ka rms) AC23A/AC3 category V AC 50/60 Hz Icm Icw V 1150 V 0.5 s 1 s 3 s Mechanical and electrical duraility as per IEC /3 at In/Ie Service life Mechanical with maintenance C/O cycles x 1000 without maintenance Type of circuit reaker Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC V 1150 V Type of circuit reaker or switch-disconnector Rated operational current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC V Type of circuit reaker or switch-disconnector Rated operational current Ie (A) AC3 (6) Motor power 380/415 V (kw) 440 V (5) (kw) 690 V (kw) C/O cycles x 1000 Electrical without maintenance 440/690 V (5) IEC Annex M/IEC

25 Masterpact NT and NW Sensor selection Sensor rating (A) 250 (1) Ir threshold setting(a) to 250 to 400 to 630 to 800 to 1000 to 1250 to 1600 to 2000 to 2500 to 3200 to 4000 to 5000 to 6300 (1) For circuit-reaker NW02, please consult us. NW08 NW10 NW12 NW16 NW20 NW25 NW32 NW40 NW40 NW50 NW to to to to to to to to to to to 6300 N1 H1 H2 L1 (2) H10 H1 H2 H3 L1 (2) H10 H1 H2 H3 H10 H1 H % 100 % 100 % 100 % B B B B < 70 < 70 < 70 < HA HF (3) HA HF (3) HA HF (3) HA % 100 % 100 % 100 % NW08/NW10/NW12 NW16 NW20 NW25/NW32/NW40 NW40/NW50/NW63 NA HA HF HA10 HA HF HA10 HA HF HA10 HA HF HA10 HA N1/H1/H2 L1 H10 H1/H2 H3 L1 H10 H1/H2 H3 H10 H1 H2 800/1000/1250/ /3200/ /5000/ H1/H2/HA/HF H1/H2/H3/HA/HF H1/H2/H3/HA/HF H1/H2/HA 800/1000/1250/ /3200/ /5000/ H1/H2/HA/HF H1/H2/H3/HA/HF to to to to to to to to to to 1300 y to to to to

26 Masterpact NT and NW Masterpact NW10 to NW40 DC circuit reakers from 800 to 6300 A 0 E PB NW10DC 4P. Masterpact circuit reaker Numer of poles Version C or D Version E Electrical characteristics as per IEC / and EN / Rated current at 40 C / 50 C (1) In (A) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kv peak) Rated operational voltage Ue (V DC) Type of circuit reaker Ultimate reaking capacity L/R = 5 ms Icu (ka) V DC L/R = 15 ms Icu L/R = 30 ms Icu Service reaking capacity Ics % Icu Rated making capacity Icm % Icu Short-time withstand current Icw 1 s Utilisation category Breaking time (ms) Making time (ms) Suitaility for isolation Pollution degree (as per IEC ) Protection against overcurrents (see "LV circuit reakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Built-in Protection Overloads Short-circuits Duraility (O/F cycles) Mechanical With maintenance Without maintenance Electrical Without maintenance 500 V CC 900 V CC Indication and control auxiliaries Auxiliary contacts Voltage release MX shunt release MN undervoltage release Characteristics of switch-disconnectors as per IEC and EN Type of switch-disconnector Rated making capacity Icm (ka) Rated short-time withstand current Icw (ka) 1 s Installation and connections Connection Drawout 3P RC Horizontal 4P Vertical Fixed 3P RC Horizontal 4P Vertical Dimensions and weight Dimensions H x W x D (mm) connected in series Weight (kg) connected in series (approximate values) (1) 50 C - see the derating tale for the NW40. Drawout Fixed Drawout Fixed 3P 4P 3P 4P 3P 4P 3P 4P 24

27 Masterpact NT and NW 0 NW10 NW20 NW / / /900 N H N H N H % 100 % B 30 to 75 < HA HA HA x 441 x x 441 x x 556 x x 556 x x 422 x x 422 x x 537 x x 537 x to to to to

28 Masterpact NT and NW Micrologic control units Overview of functions 0 All Masterpact circuit reakers are equipped with a Micrologic control unit that can e changed on site. Control units are designed to protect Power circuits and loads. Alarms may e programmed for remote indications. Measurements of current, voltage, frequency, power and power quality optimise continuity of service and energy management. Dependaility Integration of protection functions in an ASIC electronic component used in all Micrologic control units guarantees a high degree of reliaility and immunity to conducted or radiated disturances. On Micrologic A, P and H control units, advanced functions are managed y an independent microprocessor. Accessories Certain functions require the addition of Micrologic control unit accessories, descried on "LV circuit reakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN. The rules governing the various possile cominations can e found in the electronic catalogue (E-catalogue) accessile via the Products menu of the we site. Micrologic name codes Current protection 2.0 A X Y Z X: type of protection 2 for asic protection 5 for selective protection 6 for selective + earth-fault protection 7 for selective + earth-leakage protection. Y: control-unit generation Identification of the control-unit generation. "0" signifies the first generation. Z: type of measurement A for "ammeter" P for "power meter" H for "harmonic meter". DB Micrologic 2: asic protection Protection: long time + instantaneous Micrologic 5: asic protection DB Protection: long time + short time + instantaneous PB DB Micrologic 6: selective + earth-fault protection DB Protection: long time + short time + instantaneous + earth fault up to 3200 A Micrologic 7: selective + earth-leakage protection DB DB Protection: long time + short time + instantaneous + earth leakage up to 3200 A 26

29 Masterpact NT and NW Measurements and programmale protection A: ammeter I 1, I 2, I 3, I N, I earth-fault, I earth-leakage and maximeter for these measurements fault indications settings in amperes and in seconds. P: A + power meter + programmale protection measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, V peak, A peak, power factor and maximeters and minimeters IDMTL long-time protection, minimum and maximum voltage and frequency, voltage and current imalance, phase sequence, reverse power load shedding and reconnection depending on power or current measurements of interrupted currents, differentiated fault indications, maintenance indications, event histories and time-stamping, etc. H: P + harmonics power quality: fundamentals, distortion, amplitude and phase of harmonics up to the 31st order waveform capture after fault, alarm or on request enhanced alarm programming: thresholds and actions. 2.0 A DB A 5.0 P 5.0 H DB DB DB A 6.0 P 6.0 H DB DB DB A 7.0 P 7.0 H DB DB DB

30 Interpact INS Interpact INS40 to 160 switch-disconnectors a a a a-38 Interpact INS80 switch-disconnector. Interpact INS40 emergency-off switch-disconnector. Interpact INS160 switch-disconnector. Interpact INS160 emergency-off switch-disconnector. Interpact INS switch-disconnectors Numer of poles Electrical characteristics as defined y IEC / and EN / Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz V V V (1) 500 V V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz V 230 V (NEMA) V 440 V 480 V (NEMA) V V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz V V 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. 28

31 Interpact INS INS40 INS63 INS80 INS100 INS125 INS AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A , , class % class % class % class % class % class % AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A III III III III III III

32 Interpact INS Interpact INS40 to 160 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB

33 Interpact INS INS40 INS63 INS80 INS100 INS125 INS < Nm < < Nm < < Nm < < Nm < < Nm < < Nm < x 90 x x 90 x x 90 x x 135 x x 135 x x 135 x x 90 x x 90 x x 90 x x 135 x x 135 x x 135 x x 115 x x 115 x x 115 x x 160 x x 160 x x 160 x 55 31

34 Interpact INS Interpact INS to 630 switch-disconnectors a a a a-41 Interpact INS250 switch-disconnector. Interpact INS250 emergency-off switch-disconnector. Interpact INS400 switch-disconnector. Interpact INS switch-disconnectors Numer of poles Electrical characteristics as defined y IEC / and EN / Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz V V V (1) V V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz V 230 V (NEMA) V 440 V 480 V (NEMA) V V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) 550 A (DC). Interpact INS400 emergency-off switch-disconnector. 32

35 Interpact INS INS INS INS INS250 INS320 INS400 INS500 INS (2) AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC23B class % class % class % class % class % class % class % class % AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC23A DC23B DC23A DC23B DC23A DC23B DC23A DC23B III III III III III III III III - 33

36 Interpact INS Interpact INS to 630 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB

37 Interpact INS INS INS INS INS250 INS320 INS400 INS500 INS < Nm < < Nm < < Nm < < Nm < < Nm < < Nm < < Nm < < Nm < x 140 x x 140 x x 140 x x 140 x x 185 x x 185 x x 185 x x 185 x x 140 x x 140 x x 140 x x 140 x x 185 x x 185 x x 185 x x 185 x x 300 x x 300 x x 300 x x 300 x x 400 x x 400 x x 400 x x 400 x

38 Interpact INS Interpact INS630 to 2500 switch-disconnector 0 PB100016a-55 Interpact INS switch-disconnectors Numer of poles Electrical characteristics as defined y IEC / and EN / Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz V Interpact INS1600 switch-disconnector V V (1) PB100018a V V PB100020a-65 Interpact INS1600 emergency-off switch-disconnector. Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz V V 415 V V V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 0.5 s 0.8 s 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz V V V (1) V V Interpact INS2500 switch-disconnector. Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) For vertical connection usars only. For horizontal connection usars, see derating charts in the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue. 36

39 Interpact INS INS630 INS800 INS1000 INS1250 INS1600 INS2000 INS (2) (2) AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23A AC21B AC22B AC23B AC21B AC22B AC23B DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 1600/2 2000/2 2000/2-2500/2 2500/2-630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 1600/4 2000/4 2000/4-2500/4 2500/ class % class % class % class % class % class % class % AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23B AC21B AC22B AC23B AC21B AC22B AC23B DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23B DC21B DC22B DC23B DC21B DC22B DC23B III III III III III III III 37

40 Interpact INS Interpact INS630 to 2500 switch-disconnector 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB

41 Interpact INS INS630 INS800 INS1000 INS1250 INS1600 INS2000 INS x 340 x x 340 x x 340 x x 340 x x 340 x x x x x x 410 x x 410 x x 410 x x 410 x x 410 x x x x x

42 Interpact INV Interpact INV100 to 630 switch-disconnectors a a a-54 Interpact INV250 switch-disconnector. Interpact INV250 emergency-off switch-disconnector. Interpact INV400 Std. Interpact INV switch-disconnectors Numer of poles Electrical characteristics as defined y IEC / and EN / Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz V V V (1) V V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz V 230 V (NEMA) V 440 V 480 V (NEMA) V V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) 550 A (DC) a-52 Interpact INV400 emergency-off switch-disconnector. 40

43 Interpact INV INV100 INV160 INV200 INV250 INV320 INV400 INV500 INV (2) AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B / / / / /630 DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B / / class % class % class % class % class % class % class % class % AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B / / /200 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B /200 III III III III III III III III - 41

44 Interpact INV Interpact INV100 to 630 switch-disconnectors 0 Interpact INV switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB

45 Interpact INV INV100 INV160 INV200 INV250 INV320 INV400 INV500 INV < Nm < < Nm < < Nm < < Nm < < Nm < < Nm < < Nm < < Nm < x 140 x x 140 x x 140 x x 140 x x 185 x x 185 x x 185 x x 185 x x 140 x x 140 x x 140 x x 140 x x 185 x x 185 x x 185 x x 185 x x 300 x x 300 x x 300 x x 300 x x 400 x x 400 x x 400 x x 400 x

46 Interpact INV Interpact INV630 to 2500 switch-disconnectors 0 PB100017a-55 Interpact INV switch-disconnectors Numer of poles Electrical characteristics as defined y IEC / and EN / Conventional thermal current (A) Ith at 60 C Conventional thermal current in enclosure Ithe at 60 C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz V Interpact INV1600 switch-disconnector V V (1) PB100019a V V PB100021a-65 Interpact INV1600 emergency-off switch-disconnector. Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kw) Electrical AC 50/60 Hz V V 415 V V V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (ka peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit reaker) Short-time withstand current (A rms) Icw 0.5 s 0.8 s 1 s 3 s 20 s 30 s Suitaility for isolation Duraility (O-F cycles) Mechanical Electrical AC 50/60 Hz V V V (1) V V Interpact INV2500 switch-disconnector. Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visile reak Emergency-off switch disconnector Degree of pollution Upstream protection See the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue (1) Suitale for 480 V NEMA. (2) For vertical connection usars only. For horizontal connection usars, see derating charts in the LV switch-disconnectors - Interpact INS/INV 40 to 2500 A catalogue. 44

47 Interpact INV INV630 INV800 INV1000 INV1250 INV1600 INV2000 INV (2) (2) AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23A AC21B AC22B AC23B AC21B AC22B AC23B DC21A DC22A DC23A DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 1600/2 2000/2 2000/2-2500/2 2500/2-630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 1600/4 2000/4 2000/4-2500/4 2500/ class % class % class % class % class % class % class % AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23B AC21B AC22B AC23B AC21B AC22B AC23B DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B III III III III III III III 45

48 Interpact INV Interpact INV630 to 2500 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a ackplate Connection By cales By cales with lugs Flat-facing ars Edgewise ars Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module To are cale connectors Directly to terminals To spreaders To vertical-connection adapters via cale-lug adapters Directly to terminals To spreaders To vertical-connection adapters Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assemly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cale connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-arrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) Approximate weight (kg) Enclosure dimensions for Ithe 3 poles 4 poles 3 poles 4 poles H x W x D (mm) DB

49 Interpact INV INV630 INV800 INV1000 INV1250 INV1600 INV2000 INV x 340 x x 340 x x 340 x x 340 x x 340 x x x x x x 340 x x 340 x x 340 x x 340 x x 340 x x x x x

50 O OFF ON I O OFF ON I Manual source-changeover sytems Interpact INS and Compact NS 40 A to 630 A 0 Range Interpact Compact Models INS40 to INS80 NS100 to INS160 INS250 to INS630 INV250 to INV630 NS100 to NS250 NS400 to NS630 Rating (A) 40 to to to 630 Type of device Switch-disconnectors with Switch-disconnectors N/H/L circuit reakers extended handles NA switch-disconnectors Manual source-changeover systems Interlocking via toggles DB DB devices side-y-side 3 devices side-y-side Interlocking via rotary handles DB DB DB DB devices side-y-side Interlocking via keylocks with captive keys DB DB DB A numer of different devices Interlocking on a ase plate DB DB devices side-y-side Complete source-changeover assemlies DB DB devices side-y-side 48

51 push OFF O O OFF O OFF push ON I discharged O push OFF push ON I O push OFF push ON I Manual source-changeover sytems Compact NS and Masterpact NT/NW 630 A to 6300 A0 Range Compact Masterpact Models NS630 to NS1600 NT06 to NT16 NW08 to NW63 Rating (A) 630 to to to 6300 Type of device Manual source-changeover systems Interlocking via extended rotary handles N/H/L circuit reakers NA switch-disconnectors H1/L1 circuit reakers HA switch-disconnectors N1/H1/H2/H3/L1 circuit reakers NA/HA/HF switchdisconnectors DB devices side-y-side DB Interlocking via keylocks with captive keys DB DB DB O OFF discharged DB O OFF discharged A numer of different devices Mechanical interlocking using connecting rods DB DB push OFF O push ON I DB DB devices one aove the other discharged Mechanical interlocking using cales (1) DB DB DB DB or 3 devices one aove the other DB or 3 devices side-y-side For this case and other cases, please consult us (1) (2) DB (1) Implemented with NS630 to NS1600 electrically-operated devices only. (2) For source-changeover systems using cales, always respect the installation conditions. 49

52 O OFF push ON I push OFF O discharged O OFF discharged Remote-operated source-changeover systems Compact NS100/ A to 1600 A 0 Range Compact Models NS100 to NS630 NS630 to NS1600 Rating (A) 100 to to 1600 Type of device Remote-operated source-changeover system Mechanical interlocking on ase plate + electrical interlocking N/H/L circuit reakers NA switch-disconnectors N/H/L circuit reakers NA switch-disconnectors DB DB electrically-operated devices side-y-side comined with an electrical interlocking system Mechanical interlocking using connecting rods + electrical interlocking DB DB push OFF O push ON I 2 electrically-operated devices one aove the other comined with an electrical interlocking system Mechanical interlocking using cales + electrical interlocking DB DB electrically-operated devices one aove the other comined with an electrical interlocking system DB DB electrically-operated devices side-y-side comined with an electrical interlocking system Automatic source-changeover systems Remote-operated source-changeover system comined with an automatic-control system The automatic controller operates the devices depending on external parameters. DB (2) DB BA: Simple controller that manages the changeover function. UA: Controller that also manages engine generator sets. UA150: UA controller with a communication option. (2) For source-changeover systems using cales, always respect the installation conditions. DB BA controller UA and UA150 controller 50

53 Remote-operated source-changeover systems Masterpact NT/NW 630 A to 6300 A0 Range Masterpact Models NT06 to NT16 NW08 to NW63 Rating (A) 630 to to 6300 Type of device H1/L1 circuit reakers HA switch-disconnectors Remote-operated source-changeover system Mechanical interlocking using connecting rods + electrical interlocking N1/H1/H2/H3/L1 circuit reakers NA/HA/HF switch-disconnectors DB DB DB electrically-operated devices side-y-side comined with an electrical interlocking system Mechanical interlocking using cales + electrical interlocking DB DB DB or 3 electrically-operated devices one aove the other comined with an electrical interlocking system (1) DB DB or 3 electrically-operated devices side-y-side comined with an electrical interlocking system (1) (2) Automatic source-changeover systems Remote-operated source-changeover system comined with an automatic-control system The automatic controller operates the devices depending on external parameters. DB DB BA: Simple controller that manages the changeover function. BA controller UA: Controller that also manages engine generator sets. UA150: UA controller with a communication option. (1) Three devices with Masterpact NW only. (2) For source-changeover systems using cales, always respect the installation conditions. For other cases, please consult us. DB UA and UA150 controller 51

54 Fupact Fupact INFp32 to INFp800 switch-disconnector fuses INFB32. INFC63. INFD160. INFD400. Fupact INFp switch-disconnector fuses Numer of poles / type of fuse-link 3 poles / 3 fuse-links 4 poles / switched neutral 4 poles / 4 fuse-links Electrical characteristics as defined y IEC / IEC and EN / EN Conventional thermal current (A) In free air Ith at 40 C Maximum fuse power dissipation (W) In enclosure Ithe at 40 C Maximum fuse power dissipation (W) Rated insulation voltage (V) Ui AC 50/60 Hz / DC Rated impulse-withstand voltage (kv) Uimp Rated operational voltage (AC20 and DC20) (V) Ue Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational current (A) Ie AC 50/60 Hz 220/240 V 380/415 V 440/480 V (1) 500/525 V 660/690 V DC 125 V/nr of poles in series 250 V/nr of poles in series 440 V/nr of poles in series 500 V/nr of poles in series 750 V/nr of poles in series Rated operational power (kw) (3) AC 220/240 V (motor power given for direct on-line starting) 380/400 V 415 V 500/525 V 660/690 V Rated duties Uninterrupted duty Intermittent duty Rated short-circuit making capacity (ka peak) Switch-disconnector without fuse (refer to singlephase fuse limitation curves) Icm 415 V 500 V 690 V Rated short-circuit reaking capacity (ka rms) / Rated short-circuit making capacity (ka peak) (4) Icn / Icm 415 V (BS) 500 V (DIN) 690 V (DIN) Rated short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Endurance (category A) (CO cycles) Mechanical Elec. AC AC22A 500 V AC22A 690 V AC23A 500 V AC23A 690 V Suitaility for isolation Positive contact indication Pollution degree Control Direct front rotary handle Extended front rotary handle Extended lateral rotary handle Locking y padlocks Operating torque (typical for 3 poles switch-disconnector fuses) (Nm) Indication auxiliaries Auxiliary contacts Blown-fuse indicator Fuse monitor Auxiliary contact test position (1) Suitale for 480 V NEMA. (2) AC23B. (3) Some fuse-links limit these values. Motor starting current must e considered separately. (4) Switch-disconnector comined with fuses. (5) Only for NFC fuse-links. (6) Only for DIN fuse-links. 52

55 Fupact 0 INFp32 INFD40 INFp63 INFB100 INFC125 INFp160 INFp250 INFp400 INFp630 INFp800 NFC-BS DIN NFC-DIN-BS BS NFC DIN-BS DIN-BS DIN-BS DIN-BS DIN-BS NFC-BS DIN NFC-DIN-BS BS NFC DIN-BS DIN-BS DIN-BS DIN-BS DIN-BS NFC - NFC-DIN - NFC DIN DIN DIN DIN DIN AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A (2) (2) (2) (2) DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A 32/2 32/2 40/2 40/2 63/3 63/3 100/2 100/2 125/2 125/2 160/2 160/2 250/2 250/2 400/2 400/2 630/2 630/2 800/2 800/2 32/4 32/4 40/4 40/4 63/3 63/3 100/2 100/2 125/2 125/2 160/2 160/2 250/2 250/2 400/2 400/2 630/2 630/2 800/2 800/2 32/4 32/4 40/4 40/4 63/3 63/3 100/2 100/2 125/2 125/2 160/2 160/2 250/2 250/2 400/2 400/2 630/2 630/2 800/2 800/ /4 100/4 100/4 100/4 100/4 100/4 250/3 250/3 400/3 400/3 630/3 630/3 800/3 800/ /3 250/3 400/3 400/3 630/3 630/3 800/3 800/ class % class % class % class % class % class % class % class % class % class % /176 80/176 80/176 80/176 80/176 80/176 80/176 80/176 80/176 80/ / / / / / / / / / /220 50/105 50/105 50/105 50/105 50/105 50/105 50/105 50/105 50/105 50/ yes yes yes yes yes yes yes yes yes yes III III III III III III III III III III (5) - (5) - - (6) (6) (6) (6) (standard) (standard) (standard) (standard) (standard) (standard) (optional) (optional) (optional) (optional) 53

56 Fupact Fupact INFp32 to INFp800 switch-disconnector fuses 0 Fupact INFp switch-disconnector fuses Type of fuse-link NFC 10 x x x 58 DIN (NH) NH000 NH00 NH0,1 NH0,1,2 NH3 BS (fixing centres in mm) (3) A1 (44,5) F1 A2 (73,0) A3 (73,0) A4 (93,7) B1 (111) B2 (111) B3 (111) B4 (111) C1 (133) C2 (133) C3 (133) Installation and connection Fixed front connection Terminal tightening torque (Nm) Fuse-link olts tightening torque (Nm) Installation and connection accessories Bare-cale connectors Terminals Neutral link Terminal shields Dimensions and weight Overall dimensions H x W x D (mm) 3P 4P Approximate weight without fuses (kg) 3P 4P Enclosure dimensions for Ithe H x W x D (mm) Temperature derating (4) (5) "Vertical mounting" fuse-links in vertical position "Horizontal mounting" fuse-links in horizontal position (1) Maximum fuse ody diameter : Ø32 mm. (2) Maximum fuse ody diameter : Ø55 mm. (3) A: fuse-link with centre olted tags. B: fuse-link with offset olted tags. (4) Derating data is ased on: - the maximum rating for fuse-links intended for the device, - maximum heat loss. (5) For installation on a ceiling, derate an additional 10 %. Ith (A) Ith (A)

57 Fupact INFp32 INFD40 INFp63 INFB100 INFC125 INFp160 INFp250 INFp400 INFp630 INFp (1) - (1) (2) M5: 3.5 M8: 5 - M5: 3.5 M8: (standard) (standard) (standard) (optional) (optional) (optional) (optional) (optional) (optional) (optional) x 106 x x 106 x x 143 x x 180 x x 180 x x 180 x x 278 x x 302 x x 378 x x 408 x x 142 x x 142 x x 188 x x 215 x x 215 x x 215 x x 340 x x 372 x x 458 x x 498 x x350x x 350 x 300 / 500 x 400 x x 700 x 300 / 800 x 600 x 270 NFC-BS DIN NFC-DIN-BS BS NFC DIN-BS DIN-BS DIN-BS DIN-BS DIN-BS

58 Fupact Fupact ISFT100 to ISFT630 fuse-switch disconnectors ISFT100. ISFT160. ISFT630. Fupact ISFT fuse-switch disconnectors Numer of poles / type of fuse-link IEC Section 1 Electrical characteristics as defined y IEC / IEC and EN / EN Conventional thermal current (A) In free air Ith at 40 C Maximum fuse power dissipation (W) In enclosure Ithe at 40 C Maximum fuse power dissipation (W) Rated insulation voltage (V) Ui AC 50/60 Hz / DC Rated impulse-withstand voltage (kv) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage (AC20 and DC20) (V) Ue Rated operational current (A) Ie AC 50/60 Hz 220/240 V 380/415 V 440/480 V (2) 500 V 660/690 V DC/poles in series 125 V /Nr of poles 220 V /Nr of poles 440 V /Nr of poles Rated duties Uninterrupted duty Rated short-circuit reaking capacity (ka rms) / Rated short-circuit making capacity (ka peak)/ In fuse-link (A) (3) Endurance (category B) (CO cycles) Icn/Icm/In fuse-link Mechanical Electrical AC Suitaility for isolation Visile reak Pollution degree Control Direct front rotary handle (operator-dependent opening and closing) Locking Padlocks Lead seal Indication auxiliary Auxiliary contacts Blown-fuse indicator Installation and connection accessories Mounting position Horizontal Vertical Bare-cale connectors Other connectors For are Cu/Al cales For flexile ars Distriution connector Lugs for copper cales Com usars Insulated com covers Incoming connector for com usars Terminal shields Dimensions and weight Overall dimensions H x W x D (mm) 3P Approximate weight without fuse-links (kg) 3P (1) With 95 mm 2 connector. (2) Suitale for 480 V NEMA. (3) Fuse-switch disconnector with fuse-links. 415 V 500 V 690 V AC22B 415 V AC21B 690 V 56

Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access

More information

Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A Electrical distriution LV product characteristics Circuit protection and control devices 0.5 to 6300 A Overview of solutions Main power distriution oard for commercial applications Main power distriution

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06

More information

EasyPact from 15 A to 400 A

EasyPact from 15 A to 400 A LV circuit breakers 0 EasyPact from 15 A to 400 A Catalogue 2007 EasyPact General contents 0 Presentation 6 Circuit breakers 9 Installation guide 47 Busbars 71 1 The Guiding System, the new way to create

More information

Masterpact NT and NW LV power circuit breakers and switch-disconnectors

Masterpact NT and NW LV power circuit breakers and switch-disconnectors Low oltage Masterpact NT and NW LV power circuit reakers and switch-disconnectors Catalogue 2009 Presentation Masterpact NT and NW The standard for power circuit reakers around the world. Oer the years,

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

C60H-DC C curve. Catalogue numbers

C60H-DC C curve. Catalogue numbers distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011 Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

Compact NSX100 to 630

Compact NSX100 to 630 Low Voltage Compact NSX00 to 30 Circuit reakers and switch-disconnectors Sustitution guide - Technical characteristics 200 Sustitution guide Technical characteristics Performance levels and trip units

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Compact Merlin Gerin 80 to 3200 A

Compact Merlin Gerin 80 to 3200 A LV power air circuit breakers and switch-disconnectors Catalogue Compact Merlin Gerin 80 to 3200 A 2005 Industries SA 5, rue Nadar 92506 Rueil-Malmaison Cedex France Tel : +33 (0)1 41 29 82 00 Fax : +33

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Low voltage. EasyPact EZC. Moulded-case circuit breakers from 15 to 630 A. Catalogue 2013

Low voltage. EasyPact EZC. Moulded-case circuit breakers from 15 to 630 A. Catalogue 2013 Low voltage EasyPact EZC Moulded-case circuit breakers from 15 to 630 A Catalogue 2013 EasyPact EZC General contents Presentation 2 Functions and characteristics A-1 Busbars B-1 Installation guide C-1

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

Cascading & Discrimination

Cascading & Discrimination Cascading & Discrimination Typical LV System Level 1 ACBs - 6300A General LV Switchboard Level 2 ACB - 3200A MCCB 3200A Level 3 MCCB 1250A Fuses 630A Switchboard, Panelboard or MCC Level 4 MCBs - 100A

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

NS Feeder pillar up to 3200A

NS Feeder pillar up to 3200A NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

Medium Voltage Distribution. NEX 17.5 kv. Withdrawable vacuum circuit breaker. Catalogue November 2008

Medium Voltage Distribution. NEX 17.5 kv. Withdrawable vacuum circuit breaker. Catalogue November 2008 Medium Voltage Distriution NEX 17.5 kv Withdrawale vacuum circuit reaker Catalogue Novemer 2008 A new path for achieving your electrical installations A comprehensive offer The NEX 17.5 range is part of

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

Compact NS. Installation recommendations

Compact NS. Installation recommendations Compact NS Installation recommendations Presentation 6 Functions and characteristics Operating conditions 144 Installation in switchboards 145 Power supply and weights 145 Safety clearances and minimum

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

EasyPact TM : Build your complete solution with Schneider Electric

EasyPact TM : Build your complete solution with Schneider Electric Easy to choose EasyPact TM brings you easy solutions > From 15 A to 400 A > Up to 50 ka at 415 V > Up to 4 poles > In only three frame sizes > With a complete range of auxiliaries: rotary commands, auxiliaries,

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma... Contents Acti 9 MCBs, RCCB ic60h circuit breakers (curve B, C, D)... pages / to /4 ic60h and ic60h RCB0 10, 30 and 100 ma.... pages /5 to /8 Vigi ic60 add-on residual current devices.... pages /9 to /1

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Low voltage distribution products

Low voltage distribution products Price List Low voltage distribution products With effect from June 03, 2013 Price List Contents Prisma ipm: A range of Kit based LV panels.............. 1 EasyPact EZC: Range Overview...................................

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

C1251N DC and C1251N 1000 V

C1251N DC and C1251N 1000 V T I Catalogue numbers C25N DC and C25N 000 V E2409 Compact C25N DC with magnetic trip unit (complete device - fixed/fc) Compact C25N DC P2 46034 P4 46036 C25N 000 V basic frame (separate components - fixed/fc)

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

4. CIRCUIT BREAKERS (Continued)

4. CIRCUIT BREAKERS (Continued) 4. CIRCUIT BREAKERS (Continued) 4.3 Other Characteristics of a circuit breaker: Familiarity with the following less-important characteristics of LV circuit breakers is, however, often necessary when making

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A Extract of the technical catalogue - 20.10 SACE Tmax XT New low voltage molded-case circuit breakers up to 250A Circuit breakers for power distribution Main characteristics SACE Tmax XT molded-case circuit

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................

More information

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501R1/07 2007 Class 0613DC CONTENTS Description..............................................Page Contents General Information Line 1.........................................

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

Cascading. Complementary technical information

Cascading. Complementary technical information Cascading What is cascading? Cascading is the use of the current limiting capacity of circuit breakers at a given point to permit installation of lower-rated and therefore lower-cost circuit breakers downstream.

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

Price List. Low Voltage Distribution Products. With effect from December 29, schneider-electric.co.in

Price List. Low Voltage Distribution Products. With effect from December 29, schneider-electric.co.in Price List Low Voltage Distribution Products With effect from December 29, 2016 schneider-electric.co.in Price List Contents Smart Panels Introduction to Smart Panels............................... 5

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

Price List. Low Voltage Distribution Products. With effect from March 12, schneider-electric.co.in

Price List. Low Voltage Distribution Products. With effect from March 12, schneider-electric.co.in Price List Low Voltage Distribution Products With effect from March 12, 2018 schneider-electric.co.in Price List Contents Smart Panels Introduction to Smart Panels............................... 5 Moulded

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information