Product Data Sheet. Coriolis Flow Meter RCT1000 DESCRIPTION APPLICATIONS MAINTENANCE OPERATION FLUID DIAGNOSTICS ADVANTAGES

Size: px
Start display at page:

Download "Product Data Sheet. Coriolis Flow Meter RCT1000 DESCRIPTION APPLICATIONS MAINTENANCE OPERATION FLUID DIAGNOSTICS ADVANTAGES"

Transcription

1 oriolis Flow Meter ESRIPTION RT1000 The RT1000 oriolis mass flow meter identifies flow rate by directly measuring mass flow and density of fluids over a wide range of process temperatures with a high degree of accuracy. For homogenous fluids consisting of two components like sugar and water, the RT1000 oriolis system can derive the concentration and mass of each component based on fluid properties and density measurement. Furthermore, the unobstructed, open flow design makes it suitable for a variety of fluids such as slurries and other viscous, nonconductive fluids that are difficult to measure with other technologies. PPLITIONS The oriolis design and measurement principle allows the meter to be an exceptional device in measuring: Vegetable oils and fats Homogeneous suspensions and slurries dhesives, glues or binding materials oatings and hardeners yes, fragrances, vitamins and other additives OPERTION oriolis flow meters simultaneously measure mass flow rate, density and temperature. s fluid flows through the vibrating sensor tube, forces induced by the flow cause the tube to twist slightly. These small deflections are measured by carefully placed sensors. phase shift occurs between sensor signals that is directly proportional to mass flow rate. s the fluid density varies, the resonant frequency at which the tube vibrates changes which is also measured by the sensors. Larger sensors have two tubes that are vibrated in opposing directions in order to reduce the effect of process vibration on the flow measurement. Temperature is measured by an internal RT in order to calculate thermal effects on the tube vibrating frequency. ONTROLS SYSTEM INTEGRTION RT1000 transmitters provide a variety of means to integrate the meter s output into new and existing operations. The batch and PI functionality enables direct control of devices, such as valves, by use of digital or analog outputs. dditionally, programmable digital outputs can indicate low and high alarm conditions. Network options are available including EtherNet/IP, Modbus TP/IP and Modbus RTU. MINTENNE With no internal moving parts, the vibrating tube design has little impact on mechanical wear, resulting in a longer life expectancy and in fewer repairs than many other flow technologies. FLUI IGNOSTIS RT onsole software offers much more than configuration features. Users can obtain advanced data logging and performance trending analysis, as well as system verification provided by the unique HealthTrack feature, which captures critical operation parameters. VNTGES Highly accurate measurement of: Mass flow ensity erive concentration of homogenous liquids containing two components Open flow path Low maintenance operation Flexible integration options dvanced fluid diagnostic software RL-S EN-08 () Product ata Sheet

2 oriolis Flow Meter, RT1000 SPEIFITIONS System RS005, RS008 ±0.1% of reading ±0.05% of full scale RS018, RS025, RS050 ±0.2% of reading ±0.05% of full scale Uncertainty Mass Flow Rate (Liquids) RS100, RS200, RS300 (option 1) ±0.1% of reading ±0.025% of full scale RS100, RS200, RS300 (option 6) ±0.1% of reading* RS005, RS008 Mass Flow Rate (Gas) RS018, RS025, RS050 ±0.5% of reading ± 0.05% of full scale; 7:1 typical RS100, RS200, RS300 ±0.5% of reading ± 0.025% of full scale; 7:1 typical ensity RS005, RS008, RS018, RS025, RS050 ± lb/ft 3 (0.002 g/cm 3 ) RS100, RS200, RS300 ± lb/ft 3 ( g/cm 3 ) Repeatability RS005, RS008, RS018, RS025, RS050, RS100, RS200, RS300 ±0.05% of reading ± zero stability RS005, RS008, RS018, RS025, RS050 ±0.05% of full scale RS100, RS200, RS300 (option 1) ±0.025% of full scale Zero Stability RS100 (option 6) ±0.123 lb/min (3.35 kg/hr) RS200 (option 6) ±0.360 lb/min (9.79 kg/hr) RS300 (option 6) ±0.320 lb/min (8.71 kg/hr) Safety ertifications Ordinary Location UL /S 22.2 No :2010 ensity Measurement Flowing, referenced, PI, rix, aume and net oil onformance E * When flow rate is less than 10% of full scale, accuracy = ±[0.1% + (zero stability / flow rate) 100%] of rate. Flow Rate Specifications Sensors Nominal Line and Equivalent Pipe Size Number of Flow Tubes Flow Range Volumetric Equivalent 1g/cm 3 lb/min kg/hr gal/min l/h RS005 1/4 in., 1/16 in RS008 1/4 in., 3/32 in RS018 1/2 in., 3/16 in RS025 1/2 in., 1/4 in RS050 1/2 in., 1/2 in RS100 1 in , ,716 RS200 2 in , ,266 RS300 3 in , ,520 Maximum llowable Pressure by onnection Type O-Ring Face Sealing NPT lass 150 Flange lass 300 Flange RS psi (190 bar) RS psi (124 bar) Pressure RS psi (238 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS psi (238 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS psi (229 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS psi (148 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS psi (152 bar) 275 psi (19 bar) 720 psi (49.6 bar) RS psi (19 bar) 720 psi (49.6 bar) Wetted Materials Standard 316L stainless steel Fluid Range F ( ) Temperature ccuracy ±1.8 F (1 ) Repeatability ±0.54 F (0.3 ) Process onnections NSI Flange: 150 lb, 300 lb, (RS ) NPT; (RS ) 1/4 in. O-ring face sealing (RS005 RS008) onformance SME 31.3 Pressure Piping Hydro Test NE MR0175/ISO Page 2 RL-S EN-08

3 Product ata Sheet Transmitter Enclosure Power Requirements (Standard with Every RTN Transmitter) NEM 4 [IP-65]; powder coated aluminum, polycarbonate, urethane and stainless steel 115/230V ±15% 50/60 Hz 25 W maximum 20 28V mbient Temperature F ( ) onfiguration isplay RT Input nalog I/O uxiliary Power Frequency/Pulse Output igital I/O Industrial ommunications Modular Port 15 W maximum Four button HMI or RT onsole configuration 4 line 20 character; alpha-numeric; dot matrix; LE backlighting Standard (1 input) Optional (1 auxiliary input) Outputs Inputs uilt in 100 Ω Platinum RT within the sensor body dditional 100 Ω 3 wire Platinum RT input for the secondary RT is used by customers who want to be able to calibrate their RT Three 4 20 m (0 22 m capable), maximum load 500 Ω, approximately 16 bit resolution outputs; assignable to mass flow, volume, density, temperature, concentration, PI and similar measurements. User defined fault condition output value anywhere in the 0 22 m range. Two 0 5V inputs. 20k Ω input impedance, approximately 12 bit resolution Internal 24V supply, 100 m maximum (for batching functions, frequency output channel and like applications) One open collector transistor, user configurable as rate (3 khz max output), accumulator 0 10 Hz; PWM with 1 khz carrier User assignable to rate, any totalizer, PI, temperature, density, concentration or other similar measurements. Outputs Inputs Standard Optional Module Four 5 28V, 50 m maximum current draw (external pullup resistor required) Four 5 24V, 1k Ω impedance Modbus RTU (EI 485/RS485) Modbus TP/IP & EtherNet/IP Standard onfiguration Port larms Transmission istance Other Functions US 2.0 interface (through a Mini receptacle) for RT onsole software Six Hi/Lo larms; larm status on display by default, assignable to digital I/O (limit 2 or 4) and available via digital communications Up to 100 ft (30 meters); contact factory if longer length is needed atch control, PI control. User configuration of all I/O functions LE KITS The kits include the cable assembly, cable protector and sensor cable connection cover. R R R R R R R R R R Kit, PV jacketed cable 20 ft Kit, PV jacketed cable 35 ft Kit, PV jacketed cable 50 ft Kit, PV jacketed cable 70 ft Kit, PV jacketed cable 100 ft Kit, FEP jacketed cable 20 ft Kit, FEP jacketed cable 35 ft Kit, FEP jacketed cable 50 ft Kit, FEP jacketed cable 70 ft Kit, FEP jacketed cable 100 ft Temp range: F ( ) Temp range: F ( ) RL-S EN-08 Page 3

4 oriolis Flow Meter, RT1000 IMENSIONS Electronics Enclosure 8.25 in. Minimum Top learance RTN F E 0.19 in. iameter Mounting Holes E F 9.80 in. (249.9 mm) 8.00 in. (203.2 mm) in. (261.6 mm) 4.30 in. (109.2 mm) 3.66 in. (93.0 mm) 8.32 in. (211.2 mm) Pipe Mount racket #8-32 UN-2 Screws Pipe Mount racket #8-32 UN-2 Screws Vertical Pipe Mount RTN Pipe Mounting Options Horizontal Pipe Mount E H G F Pipe racket imensions E F G H 5.50 in. (139.7 mm) 4.00 in. (101.6 mm) 1.11 in. (28.2 mm) in. (15.9 mm) 1.25 in. (31.8 mm) 3.80 in. (96.5 mm) 5.25 in. (133.6 mm) 6.00 in. (152.4 mm) Page 4 RL-S EN-08

5 Product ata Sheet Sensor imensions, RS018 RS300 Threaded Ends Threaded Ends Flanged Ends Flanged Ends RS RS Sensor Nominal Size RS018 1/2 in in. (346 mm) 7.1 in. (180 mm) 8.5 in. (217 mm) 4.5 in. (113 mm) RS025 1/2 in in. (406 mm) 9.0 in. (228 mm) 10.0 in. (253 mm) 4.5 in. (113 mm) RS050 1/2 in in. (470 mm) 11.7 in. (296 mm) 15.9 in. (405 mm) 5.2 in. (131 mm) RS100 1 in in. (590 mm) 16.8 in. (426 mm) 27.6 in. (700 mm) 6.4 in. (163 mm) RS200 2 in in. (670 mm) 18.6 in. (472 mm) 28.6 in. (726 mm) 8.0 in. (203 mm) RS300 3 in in. (1040 mm) 28.7 in. (728 mm) 40.5 in. (1028 mm) 9.6 in. (243 mm) Sensor imensions, RS005 E F G Sensor Nominal Size E F G RS005 1/4 in in. (149.9 mm) 5.00 in. (127 mm) 1.00 in. (25.4 mm) 3.60 in. (85.3 mm) 7.93 in. (201.7 mm) 2.42 in. (61.6 mm) 1.23 in. (31.2 mm) RL-S EN-08 Page 5

6 oriolis Flow Meter, RT1000 Sensor imensions, RS008 Figure 1: RS008 dimensions Sensor RS008 Nominal Size 1/4 in. E F G H J 8.48 in. (215.3 mm) 5.72 in. (145.3 mm) 6.60 in. (167.7 mm) 1.50 in. (38.1 mm) 8.70 in. (221 mm) 2.67 in. (67.8 mm) 0.98 in. (24.9 mm) 4.65 in. (118 mm) 2.48 in. (63 mm) PPROXIMTE WEIGHTS Sensor Only RS lb 2.49 kg RS lb 4.4 kg RS lb 6.80 kg RS lb 6.80 kg RS lb kg RS lb kg RS lb kg RS lb kg Transmitter Only RTN 6.5 lb 2.95 kg ables Only R820*** 20 6 lb 2.7 kg R820*** 35 8 lb 3.6 kg R820*** lb 4.5 kg R820*** lb 5.9 kg R820*** lb 7.7 kg Page 6 RL-S EN-08

7 Product ata Sheet OMPLETE REMOTE MOUNT METERING SYSTEM The complete remote mount metering system consists of the following; each component must be purchased separately: 1. Sensor 2. Transmitter 3. able assembly NETWORK OPTIONS RS-485 Network ll RT1000 meters come equipped an EI-485 port with Modbus RTU.. 10/100 ase-t Network n optional Ethernet module allows communications via Modbus TP/IP or EtherNet/IP. SOFTWRE UTILITY RT onsole software is a P based software that can be used to configure, operate and diagnose the RT1000 oriolis meter. dditionally, the software can log and graph fluid characteristics and parameters for historical comparisons. RT onsole software is included with the RT1000 oriolis meter. ESSORIES Please consult the factory for the availability, pricing and delivery estimates of additional accessories. SENSORS PRT NUMER ONSTRUTION Sensors 005 and 008 ONLY adger Meter oriolis Flow Meter Nominal Line and Equivalent Pipe Size RS 1/4 in., 1/16 in /4 in., 3/32 in. 008 Wetted Material 316L Stainless Steel Process onnection Type NPT O-Ring, Face Sealing ody, 9/16-18 Threads O-Ring, Face Sealing Gland Electronic Mounting Options Remote Mount Transmitter ertifications General/Ordinary rea alibration/meter Uncertainty Liquids (Gases) Mass Flow: 0.1% (0.5%) ± 0.05% of FS zero stability; ensity: ± g/cm3 3 Reserved None (Reserved) Specials Special ode (leave blank for non-custom orders) S NPT FSM FSF R G N XXX RL-S EN-08 Page 7

8 Sensor Part Number onstruction, Sensors adger Meter oriolis Flow Meter Nominal Line and Equivalent Pipe Size RS 1/2 in., 3/16 in. (4.76 mm) 018 1/2 in., 1/4 in. (6.35 mm) 025 1/2 in., 1/2 in. (12.70 mm) in., 1 in. (25.40 mm) in., 2 in. (50.80 mm) in., 3 in. (76.20 mm) 300 Wetted Material 316L Stainless Steel Process onnection Type NPT ( sensors only) 150 lb SME 16.5 Flange ( sensors only) F 300 lb SME 16.5 Flange ( sensors only) F Electronic Mounting Options Remote Mount Transmitter ertifications General/Ordinary rea alibration/meter Uncertainty Liquids Mass Flow: 0.1% of reading ± 0.025% of full scale (100, 200, 300 sensors only) 1 Mass Flow: 0.2% of reading ± 0.05% of full scale ( sensors only) 2 Mass Flow: 0.1% of reading (200, 300 sensors only) 6 Reserved None (Reserved) Specials Special ode (leave blank for non-custom orders) S NPT R G N XXX *Higher flange ratings and other process connection types can be provided. onsult factory for pricing and delivery estimates. TRNSMITTER PRT NUMER ONSTRUTION adger Meter oriolis Transmitter RT Enclosure Type NEM 4 [IP 65] Transmitter Options isplay and Keyboard rea lassification General rea Electronic Mounting Option Remote Mount Transmitter ommunication Protocol Modbus RTU & Modbus TP/IP Modbus RTU (Standard on all models) Sensor onnection Ordinary reas Specials 3-igit Special ode (leave blank for non-custom orders) N K 2 R E M N XXX ontrol. Manage. Optimize. Trademarks appearing in this document are the property of their respective entities. ue to continuous research, product improvements and enhancements, adger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists adger Meter, Inc. ll rights reserved. The mericas adger Meter 4545 West rown eer Rd PO ox Milwaukee, WI México adger Meter de las mericas, S.. de.v. Pedro Luis Ogazón N 32 Esq. ngelina N 24 olonia Guadalupe Inn P México, F México Europe, Middle East and frica adger Meter Europa GmbH Nurtinger Str Neuffen Germany Europe, Middle East ranch Office adger Meter Europe PO ox ubai Silicon Oasis, Head Quarter uilding, Wing, Office #209 ubai / UE zech Republic adger Meter zech Republic s.r.o. Maříkova 2082/ rno, zech Republic Slovakia adger Meter Slovakia s.r.o. Racianska 109/ ratislava, Slovakia sia Pacific adger Meter 80 Marine Parade Rd Parkway Parade Singapore hina adger Meter Hangzhong Road Minhang istrict Shanghai hina

Product Data Sheet. Positive Displacement Flow Meter B1750 DESCRIPTION

Product Data Sheet. Positive Displacement Flow Meter B1750 DESCRIPTION ESRIPTION Positive isplacement Flow Meter 175 The lancett Model 175 positive displacement flow meter provides high measurement accuracy, trouble-free operation and long service life for fluids over a wide

More information

Product Data Sheet. Flow Monitor. B2800 Series DESCRIPTION OPERATION FEATURES

Product Data Sheet. Flow Monitor. B2800 Series DESCRIPTION OPERATION FEATURES Flow Monitor 2800 Series SRIPTION The 2800 flow monitor is designed to be comprehensive, user-friendly, flexible and cost efficient. This microprocessor-based display comes pre-calibrated when purchased

More information

Product Data Sheet. Electronic Valve Actuator. SEVA (Smart Electronic Valve Actuator) DESCRIPTION FEATURES APPROVALS / RATINGS OPERATION

Product Data Sheet. Electronic Valve Actuator. SEVA (Smart Electronic Valve Actuator) DESCRIPTION FEATURES APPROVALS / RATINGS OPERATION Electronic Valve ctuator SEV (Smart Electronic Valve ctuator) DESCRIPTION The SEV is our next generation Smart Electric Valve ctuator that provides our customers with an electric actuator with best-in-class

More information

Product Data Sheet. Turbine Flow Meters. Precision Series DESCRIPTION CALIBRATIONS APPLICATIONS

Product Data Sheet. Turbine Flow Meters. Precision Series DESCRIPTION CALIBRATIONS APPLICATIONS Turbine Flow Meters Precision Series DESRIPTION ox Precision Turbine Flow Meters have unprecedented mechanical linearity, resulting in minimizing, or negating, temperature induced viscosity influence.

More information

Product Data Sheet. Exact Dual Rotor. Turbine Flow Meters DESCRIPTION CALIBRATIONS APPLICATIONS

Product Data Sheet. Exact Dual Rotor. Turbine Flow Meters DESCRIPTION CALIBRATIONS APPLICATIONS Exact Dual Rotor Turbine Flow Meters DESRIPTION The ox Exact Dual Rotor Turbine Flow Meter is the pinnacle of turbine meter technology that delivers results not attainable with single rotor designs. The

More information

Parts List. Recordall Turbo Series Meters

Parts List. Recordall Turbo Series Meters Recordall Turbo Series Meters Models 160 (1-1/ in.), 00 ( in.), 450 (3 in.), 1000 (4 in.), 000 (6 in.), 3500 (8 in.), 5500 (10 in.), 600 (1 in.) Models without Integral Strainers, Sizes 1-1/ 1 in. Models

More information

Product Data Sheet. Industrial Oval Gear. Inline and Flanged Meters, 1/2", 3/4", 1", 1" HF, 1-1/2", 2", 3" DESCRIPTION OPERATING PRINCIPLE

Product Data Sheet. Industrial Oval Gear. Inline and Flanged Meters, 1/2, 3/4, 1, 1 HF, 1-1/2, 2, 3 DESCRIPTION OPERATING PRINCIPLE Industrial Oval Gear Inline and Flanged Meters, 1/2", 3/4", 1", 1" HF, 1-1/2", 2", 3" DESCRIPTION The Badger Meter Industrial Oval Gear Meter, Model IOG is a modular flow meter design, economical yet highly

More information

Product Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION

Product Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION VN2000 Flow Meters Compact Insertion Meter DESCRIPTION The VN2000 Compact Insertion Vortex Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow

More information

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY DESCRIPTION Flow Sensors Insert Style Flow Sensors SDI Series The Data Industrial SDI Series insert flow sensors from Badger Meter offer accurate liquid flow measurement in closed pipe systems in an easy

More information

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE VN2000 Flow Meters Wafer Plate Inline Meter DESCRIPTION The VN2000 Wafer Plate Inline Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow range.

More information

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE VN2000 Flow Meters Hot Tap Insertion Meter DESCRIPTION The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow

More information

Product Data Sheet. Turbine Flow Meter. B16D Series FloClean Sanitary DESCRIPTION INSTALLATION REPAIR KITS

Product Data Sheet. Turbine Flow Meter. B16D Series FloClean Sanitary DESCRIPTION INSTALLATION REPAIR KITS DESCRIPTION Turbine Flow Meter The FloClean Sanitary turbine flow meter was developed for use in the food, beverage and pharmaceutical industries. The 36L stainless steel construction provides a durable

More information

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE VN2000 Flow Meters Hot Tap Insertion Meter DESCRIPTION The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow

More information

Variable Area Flow Meters and Flow Switches. Easy-to-Use and Reliable Flow Measurement.

Variable Area Flow Meters and Flow Switches. Easy-to-Use and Reliable Flow Measurement. Variable Area and Flow Switches Easy-to-Use and Reliable Flow Measurement. Variable Area and Flow Switches The Hedland product line features over 15,000 inline, variable area flow meters to measure oil,

More information

Product Data Sheet DESCRIPTION

Product Data Sheet DESCRIPTION Turbo Series Meters Models 16 (11/2"), 2 (2"), 4 (3"), (4"), 2 (6"), 3 (8"), ("), & 62 (12"); NSF/ANSI Standards 61 and 372 Certified DESCRIPTION Turbo Series meters meet or exceed the most recent revision

More information

Automotive Flow Measurement and Control Products

Automotive Flow Measurement and Control Products Automotive Flow Measurement and Control Products Control. Manage. Optimize. Automotive Flow Measurement and Control Products When every drop counts, choose automotive flow measurement and control products

More information

Product Data Sheet DESCRIPTION

Product Data Sheet DESCRIPTION Turbo Series Meters Models 16 (11/), 2 (), 4 (3 in.), (4 in.), 2 (6 in.), 3 (8 in.), ( in.) and 62 (1) NSF/ANSI Standards 61 and 372 Certified DESCRIPTION Turbo Series meters meet or exceed the most recent

More information

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS DESCRIPTION Turbine Flow Meter QuikSert The QuikSert in-line turbine flow meter was developed for liquid applications where accuracy and dependability are needed. QuikSert s stainless steel body incorporates

More information

Product Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8", 5/8" x 3/4", 3/4" & 1" NSF/ANSI Standards 61 and 372 Certified

Product Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8, 5/8 x 3/4, 3/4 & 1 NSF/ANSI Standards 61 and 372 Certified Recordall Disc Meters LeadFree Bronze Alloy, Sizes /8", /8" x 3/4", 3/4" & " NSF/ANSI Standards 6 and 372 Certified LP /8", /8" 3/4" 2 /8", /8" 3/4" 3 3/4" " 7 " DESCRIPTION The Recordall Disc Series meters

More information

Turbine Flow Meter. Model User Manual. TRB-UM EN-03 (December 2015)

Turbine Flow Meter. Model User Manual. TRB-UM EN-03 (December 2015) Turbine Flow Meter Model 1200 TRB-UM-00290-EN-03 () User Manual Turbine Flow Meter, Model 1200 CONTENTS Scope of This Manual 3 Unpacking and Inspection 3 Safety 3 Terminology and Symbols 3 Considerations

More information

Product Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8, 5/8 x 3/4, 3/4 & 1 inch NSF/ANSI Standards 61 and 372 Certified

Product Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8, 5/8 x 3/4, 3/4 & 1 inch NSF/ANSI Standards 61 and 372 Certified Recordall Disc Meters LeadFree Bronze Alloy, Sizes /8, /8 x 3/4, 3/4 & inch NSF/ANSI Standards 6 and 372 Certified 2 /8 in., /8 3/4 in. 3 3/4 in. in. 7 in. DESCRIPTION The Recordall Disc Series meters

More information

Product Data Sheet. Recordall Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass DESCRIPTION

Product Data Sheet. Recordall Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass DESCRIPTION Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass UL Certified & FM Standard Approved for Fire Service Applications NSF/ANSI Standards and Certified DESCIPTION Fire Series assemblies

More information

Product Data Sheet. Recordall Fire Series Assembly (FSAA) Cold Water Meter & Strainer with Turbine Bypass DESCRIPTION

Product Data Sheet. Recordall Fire Series Assembly (FSAA) Cold Water Meter & Strainer with Turbine Bypass DESCRIPTION Fire Series Assembly (FSAA) Cold Water Meter & Strainer with Turbine Bypass UL Certified & FM Standard Approved for Fire Service Applications NSF/ANSI Standards and Certified DESCIPTION Fire Series assemblies

More information

Control Valves. Type HP-10, 10,000 PSI. User Manual. RCV-UM EN-01 (August 2014)

Control Valves. Type HP-10, 10,000 PSI. User Manual. RCV-UM EN-01 (August 2014) Control Valves Type HP-10, 10,000 PSI RCV-UM-01034-EN-01 () User Manual Control Valves Type HP-10, 10,000 PSI Page ii User Manual CONTENTS Overview...........................................................................

More information

Electronic Preset Meter. Model EPM2-ADV-SF, Advanced Series, Special Fluids. User Manual. AUT-UM EN-05 (August 2015)

Electronic Preset Meter. Model EPM2-ADV-SF, Advanced Series, Special Fluids. User Manual. AUT-UM EN-05 (August 2015) Electronic Preset Meter Model EPM2-ADV-SF, Advanced Series, Special Fluids AUT-UM-00916-EN-05 () User Manual Electronic Preset Meter, Model EPM2-ADV-SF, Advanced Series, Special Fluids Page ii AUT-UM-00916-EN-05

More information

User Manual. Ellipse Pitot Tube Meter. PFA Fire Pump System. PTT-UM EN-03 (March 2017) 2500 GPM 3000 F M

User Manual. Ellipse Pitot Tube Meter. PFA Fire Pump System. PTT-UM EN-03 (March 2017) 2500 GPM 3000 F M Ellipse Pitot Tube Meter PFA Fire Pump System 500 GPM 3000 000 3500 1500 1000 PFA-XXX X inch 50 SWP X/XX S/N AXXXXXXX 4000 METERS PTT-UM-0053-EN-03 () User Manual Ellipse Pitot Tube Meter, PFA Fire Pump

More information

Series TFXL ULTRASONIC CLAMP-ON FLOW METER DIMENSIONAL SPECIFICATIONS PRODUCT INSTALLATION

Series TFXL ULTRASONIC CLAMP-ON FLOW METER DIMENSIONAL SPECIFICATIONS PRODUCT INSTALLATION Series PROUT INSTLLTION Series IMENSIONL SPEIFITIONS MEHNIL IMENSIONS: INHES (MM) Installation onsiderations 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight

More information

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene. Chemical Compatibility Chart 6 Stainless Acetic Acid Acetone Acetylene Acidic Mine Water Acrylonitrile Ammonium Chloride Ammonium Hydroxide Ammonium Sulfate Ammonium Thio-Sulfate Anhydrous Ammonia Anhydrous

More information

BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual

BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual BIN & SEN Annular Pitot Tube Flow Meter Form: 1-PTT-UM-349 (December 212) Installation & Operation Manual Installation Instructions 1. The primary station can be installed in any position on vertical or

More information

Product Data Sheet. Transit Time Ultrasonic Flow Meters. TFX-500w Clamp-On Meter DESCRIPTION FEATURES BENEFITS OPERATION APPLICATION

Product Data Sheet. Transit Time Ultrasonic Flow Meters. TFX-500w Clamp-On Meter DESCRIPTION FEATURES BENEFITS OPERATION APPLICATION Transit Time Ultrasonic low Meters TX-500w Clamp-On Meter ECRIPTION The TX-500w transit time ultrasonic flow meter measures volumetric flow of clean water in pipes 10 in. or smaller. y clamping on the

More information

User Manual. Industrial Meters. Oscillating Piston, Sizes 1/2", 1" and 2" Model OP Sanitary (3A Approved) and Model OP Chemical

User Manual. Industrial Meters. Oscillating Piston, Sizes 1/2, 1 and 2 Model OP Sanitary (3A Approved) and Model OP Chemical Industrial Meters Oscillating Piston, Sizes 1/2", 1" and 2" Model OP Sanitary (3A Approved) and Model OP Chemical OPM-DS-00291-EN-03 () User Manual Industrial Meters, Oscillating Piston, Sizes 1/2", 1"

More information

Industrial Meters. Oscillating Piston, Model OP Chemical & Sanitary, Sizes 1/2", 1", 2" User Manual. OPM-UM EN-02 (August 2013)

Industrial Meters. Oscillating Piston, Model OP Chemical & Sanitary, Sizes 1/2, 1, 2 User Manual. OPM-UM EN-02 (August 2013) Industrial Meters Oscillating Piston, Model OP Chemical & Sanitary, Sizes 1/2", 1", 2" OPM-UM-00291-EN-02 (August 2013) User Manual Industrial Meter, Oscillating Piston, Sizes 1/2" through 2" Model OP

More information

Turbine Flow Sensors. Activa, Ultima, Classic and Quad. User Manual. SEN-UM EN-02 (March 2015)

Turbine Flow Sensors. Activa, Ultima, Classic and Quad. User Manual. SEN-UM EN-02 (March 2015) Turbine Flow Sensors ctiva, Ultima, Classic and Quad SEN-UM-00987-EN-02 () User Manual Turbine Flow Sensors, ctiva, Ultima, Classic and Quad Page 2 User Manual CONTENTS Introduction.........................................................................

More information

HTTF Transit Time Ultrasonic Flow Meter

HTTF Transit Time Ultrasonic Flow Meter Installation onsiderations imensional Specifications 1. Select the optimum mounting location on the piping system a full pipe with at least 10 straight pipe diameters upstream and 5 pipe diameters downstream

More information

Electromagnetic amplifier type ModMAG M10 for all detectors

Electromagnetic amplifier type ModMAG M10 for all detectors Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Electromagnetic amplifier type ModMG M10 for all detectors

More information

Turbine Flow Meter. B16N Series FloClean Tri-Clover End Fitting. User Manual. TRB-UM EN-01 (December 2016)

Turbine Flow Meter. B16N Series FloClean Tri-Clover End Fitting. User Manual. TRB-UM EN-01 (December 2016) Turbine Flow Meter B16N Series FloClean Tri-Clover End Fitting TRB-UM-02253-EN-01 () User Manual Turbine Flow Meter, B16N Series FloClean Tri-Clover End Fitting CONTENTS Scope of This Manual 3 Unpacking

More information

Electromagnetic amplifier Primo Advanced for all detectors

Electromagnetic amplifier Primo Advanced for all detectors Electromagnetic amplifier Primo dvanced for all detectors Features ccuracy ±0,25% Flow range 0,03 12 m/s 6 2000 LC display Power supply 85 2 VC / 24 VC escription imensions The amplifier type Primo dvanced

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

Turbine Flow Meter B1500. User Manual. TRB-UM EN-02 (June 2016)

Turbine Flow Meter B1500. User Manual. TRB-UM EN-02 (June 2016) Turbine Flow Meter B1500 TRB-UM-01789-EN-02 () User Manual Turbine Flow Meter, B1500 Page ii TRB-UM-01789-EN-02 User Manual CONTENTS Safety information 5 Safety Symbol Explanations 5 Unpacking & Inspection

More information

RV SYSDrive AC Inverters

RV SYSDrive AC Inverters 7160_Omron 3/31/04 4:38 PM Page 1 OMRON IM ONTROLS, IN. RV SYSrive Inverters High-Value, 4-in-1 Inverter Solutions for General-Purpose & High-End pplications 7160_Omron 3/31/04 4:38 PM Page RV Inverter

More information

TM 301 TM 308 In-Line Torque Transducers

TM 301 TM 308 In-Line Torque Transducers ata Sheet In-Line Torque Transducers Features Integrated Torque and Speed onditioning Torque Range: 0.1 N m to 20 N m (0.07 lb ft to 15 lb ft) ccuracy: < 0.1% Overload apacity: 200% Overload Limit: 400%

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Industrial Turbo Meters. Sizes 2 in. through 6 in. User Manual. TUR-UM EN-21 (October 2017)

Industrial Turbo Meters. Sizes 2 in. through 6 in. User Manual. TUR-UM EN-21 (October 2017) Industrial Turbo Meters Sizes 2 in. through 6 in. TUR-UM-00530-EN-21 () User Manual Industrial Turbo Meters, Sizes 2 in. through 6 in. Page ii TUR-UM-00530-EN-21 User Manual CONTENTS Scope of the Manual

More information

Paddle Wheel Flow Meter

Paddle Wheel Flow Meter www.fine-tek.com Paddle Wheel Meter FineTek Lab FineTek is the company who owns a Second lass flow test laboratory in Taiwan. With the most professional R& team, FineTek develops various high precision

More information

Model 200 Multi-Jet Flow Meter. 02-PDM-UM (July 2012) Installation & Operation Manual

Model 200 Multi-Jet Flow Meter. 02-PDM-UM (July 2012) Installation & Operation Manual Model 200 Multi-Jet Flow Meter 02-PDM-UM-00109 (July 2012) Installation & Operation Manual TABLE OF CONTENTS Introduction...3 Operating Principle...3 Specifications...4 Operating Limitations...5 Installation

More information

VN2000 Flow Meters. Hot Tap Insertion Meter. User Manual. VRX-UM EN-03 (April 2018)

VN2000 Flow Meters. Hot Tap Insertion Meter. User Manual. VRX-UM EN-03 (April 2018) VN2000 Flow Meters Hot Tap Insertion Meter VRX-UM-02217-EN-03 () User Manual VN2000 Flow Meters, Hot Tap Insertion Meter Page 2 VRX-UM-02217-EN-03 User Manual CONTENTS Purpose of this Document................................................................

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES Online data sheet FLOWSIC100 VOLUME FLOW MESURING DEVICES VOLUME FLOW MESURING DEVICES B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type FLOWSIC100 Part no.

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

PFM Portable Hydraulic Testers. PFM6, PFM6BD and PFM8. User Manual. TUR-UM EN-02 (August 2014)

PFM Portable Hydraulic Testers. PFM6, PFM6BD and PFM8. User Manual. TUR-UM EN-02 (August 2014) PFM Portable Hydraulic Testers PFM6, PFM6BD and PFM8 TUR-UM-73-EN-2 () User Manual PFM Portable Hydraulic Testers, PFM6, PFM6BD and PFM8 CONTENTS Introduction.........................................................................iii

More information

U500w Ultrasonic Meter. Cold Water Meters. User Manual. ESM-UM EN-04 (September 2017)

U500w Ultrasonic Meter. Cold Water Meters. User Manual. ESM-UM EN-04 (September 2017) U500w Ultrasonic Meter Cold Water Meters ESM-UM-02205-EN-04 () User Manual U500w Ultrasonic Meter CONTENTS About the U500w Ultrasonic Meter 3 Safety Information 3 Product Unpacking and Inspection 3 Meter

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Siemens G 2017 SITRS US lamp-on Overview SITRS U1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either Wideeam

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview Flow Measurement SITRNS F US lamp-on Siemens G 2011 Overview SITRNS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can

More information

Micro Motion Technical Overview and Specification Summary

Micro Motion Technical Overview and Specification Summary Product Data Sheet PS-00232, Rev. J June 2009 Micro Motion Technical Overview and Specification Summary Emerson s world-leading Micro Motion Coriolis flow and density measurement devices have set the standard

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

Variable speed drives

Variable speed drives 5 192 Variable speed drives SED2 Variable speed drives for speed control of three-phase a.c. motors actuating fans or pumps. Range: 0.75 kw to 90 kw for IP20/21 version, 1.1 kw to 90 kw for IP54 version.

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

Turbine Flow Meter. User Manual. Top Load 1 in. and 2 in. Meters. TRB-UM EN-01 (September 2018)

Turbine Flow Meter. User Manual. Top Load 1 in. and 2 in. Meters. TRB-UM EN-01 (September 2018) Turbine Flow Meter Top Load 1 in. and 2 in. Meters TRB-UM-02597-EN-01 () User Manual Turbine Flow Meter, Top Load 1 in. and 2 in. Meters CONTENTS Unpacking and Inspection.........................................

More information

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal Positive displacement flow fitting for continuous and batch control High accuracy ± 0.5% 1/2 TO 4 (DN 15 to 100) INLINE Quarter Turn technology For highly viscous fluids Electronics for indication, monitoring,

More information

Recordall Combo Meter Lead-Free Bronze Alloy, Size 8" (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM EN-02 (October 2013) User Manual

Recordall Combo Meter Lead-Free Bronze Alloy, Size 8 (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM EN-02 (October 2013) User Manual Recordall Combo Meter Lead-Free Bronze Alloy, Size 8" (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM-00077-EN-02 (October 2013) User Manual Recordall Combo Meter, 8" Page ii October 2013 User

More information

Variable Area Flow Meters. Inline Pneumatic Flow Meter. User Manual. VAM-UM EN-02 (August 2014)

Variable Area Flow Meters. Inline Pneumatic Flow Meter. User Manual. VAM-UM EN-02 (August 2014) Variable Area Flow Meters Inline Pneumatic Flow Meter VAM-UM-00593-EN-02 () User Manual Variable Area Flow Meters, Inline Pneumatic Flow Meter CONTENTS Introduction.........................................................................

More information

Spiraflo Steam flowmeters

Spiraflo Steam flowmeters Spiraflo Steam flowmeters Using a Spiraflo steam meter from Spirax Sarco will enable you to measure steam use accurately under all load conditions. It will provide vital information on usage and associated

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

User Manual. Intrinsically Safe Flow Meters. RWG/RWBG Wafer Style Flow Meters RNG Insertion Style Flow Meters. VRX-UM EN-03 (October 2014) Flow

User Manual. Intrinsically Safe Flow Meters. RWG/RWBG Wafer Style Flow Meters RNG Insertion Style Flow Meters. VRX-UM EN-03 (October 2014) Flow Intrinsically Safe Meters RWG/RWBG Wafer Style Meters RNG Insertion Style Meters FLOW VRX-UM-00374-EN-03 () User Manual Intrinsically Safe Meters, RWG/RWBG Wafer Style Meters & RNG Insertion Style Meters

More information

Model DFX Doppler ultrasonic flow meter

Model DFX Doppler ultrasonic flow meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model DFX Doppler ultrasonic flow meter Features Badger

More information

Installation & Operation Manual. Impeller Flow Sensors. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Installation & Operation Manual. Impeller Flow Sensors. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. Impeller Flow Sensors 250 and 228 Metal Tee IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. 872021-EN (August 2012) Rev. 8 Installation & Operation Manual 250 and 228

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001 Micro Motion T-Series Straight-Tube Mass Flow and Density Meters Product Data Sheet PS-00371 July 2001 Micro Motion T-Series Straight-Tube Meters Micro Motion is proud to offer you the first single-straight-tube

More information

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control

More information

F6700 ELECTROMAGNETIC METER

F6700 ELECTROMAGNETIC METER EETROMAGNETI FOW TRANSMITTER Special Features: F6700 Full Bore type Simple and ost effective onstruction Absolutely Maintenance free Suitable for all conductive liquids and slurries Outstanding Accuracy

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in

More information

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications M2800 Series Inline Ultrasonic Flow Meter Description The M2800 consists of an inline flow sensor and electronics in one package. The flow sensor is a straightthrough PFA tube with a pair of assemblies

More information

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters EMF Series ELECTROMAGNETIC FLOWMETER Description Introduction for EMF Series of Electromagnetic Flowmeters The Electromagnetic Flowmeters(EMF) can be used to accurately measure the flowrate of liquids,

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values

More information

Flow meter Type Recordall (RCDL)

Flow meter Type Recordall (RCDL) Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Flow meter Type Recordall (RCDL) Bronze model Features

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Sensors do not overheat at zero flow by using a unique constant temperature control method and power limiting design

Sensors do not overheat at zero flow by using a unique constant temperature control method and power limiting design TECHNICL SPECIFICTIONS Multipoint Insertion Flow Meter Series K-BR 2000B The Kurz K-BR 2000B multipoint insertion flow meter for combustion control and emissions monitoring includes the qualities and features

More information

Ultrablend UB 975. Dosing and Blending: Gravimetric Dosing Systems. Description. Rugged, modular construction

Ultrablend UB 975. Dosing and Blending: Gravimetric Dosing Systems. Description. Rugged, modular construction 170 / T Esc Run Enter Stop U 75 Typical application of a gravimetrich batch blender. Gravimetric atch lender osiersteuerung Printer Host omponent is described below. escription olortronic's gravimetric

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

SV321 & SV Way Normally Closed and Normally Open Pilot Operated Solenoid Valves

SV321 & SV Way Normally Closed and Normally Open Pilot Operated Solenoid Valves SV321 & SV421 2-Way and Pilot Operated Solenoid Valves Valcor General Purpose Series ESRIPTION pplication Features These 2-way piloted diaphragm solenoid valves are available in normally closed and normally

More information

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS). PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water

More information

VB-7000 Series 1/2 to 2 Globe Valves

VB-7000 Series 1/2 to 2 Globe Valves V-7000 Series 1/2 to 2 Globe Valves with MG350V Series SmartX ctuators schneider-electric.com 1 Product Description Schneider Electric MG350V non-spring actuators and V-7000 series two and three-way globe

More information

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type Stepping Motor Driver Package High-Efficiency R Series DC Power-Supply Input Built-in Type Type The extensive R Series DC Power-Supply Input lineup that utilizes high-efficiency technology. Two types are

More information

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: Rosemount 1810 Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: A cleanable and compact stainless steel design An innovative patented venting configuration that prevents gauge reference

More information

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors. Product Data Sheet PS 00388 February 2002 Model D and DT Mass Flow and Density Sensors www.micromotion.com Model D and DT sensors Micro Motion Model D sensors set the standard for Coriolis flowmeters nearly

More information

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508 Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview. Level Measurement Pointek LS200 Standard Siemens A 20 Overview onfiguration Installation Pointek LS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable

More information

GTEC Transfer switch Open transition

GTEC Transfer switch Open transition GTE Transfer switch Open transition 40-2000 amp Description GTE transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

CZ-200P PG500 PCT-300. General Description. Features. Resin Pressure Measuring System CZ-200P. Resin Pressure Sensor CZ-200P

CZ-200P PG500 PCT-300. General Description. Features. Resin Pressure Measuring System CZ-200P. Resin Pressure Sensor CZ-200P 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 P5 P5 5 Resin Pressure Measuring System Z-2P Z-2P P5 PT-3 eneral escription Resin pressure indicator P5 Resin pressure sensor : Z-2P Output converter : PT-3 RK's resin pressure

More information