F-2700 SERIES INSERTION VORTEX FLOW METER

Size: px
Start display at page:

Download "F-2700 SERIES INSERTION VORTEX FLOW METER"

Transcription

1 F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C) standard 750 F (400 C) optional Compressed air Industrial gases CALIBRATION MADE IN THE USA Vortex flow meters detect the frequency of alternating low pressure vortices that are formed as flow is diverted around a bluff body. These swirling low pressure zones apply lateral pressure first to one side and then to the other of sensors located downstream of the bluff body. This causes the sensors to vibrate. The frequency of this vibration is directly proportional to the flow velocity. DESCRIPTION The ONICON F-2700 Series Insertion Vortex Flow Meter is a flexible design that delivers accurate, reliable flow measurement in a wide variety of applications. The integral temperature sensor and optional integral pressure sensor allow for direct mass flow measurement in steam and compensated flow measurement in compressed air and gases. A volumetric flow version of the meter is also available for liquid flow applications. ONICON insertion style vortex meters can be installed without disrupting flow making them ideal for retrofit applications. They are also a cost effective option in larger pipes as they are priced independent of the pipe diameter. A version of the F-2700 with temperature and optional pressure compensation is available as a DC loop powered (2-wire) device with analog and pulse outputs. Optional external DC and AC powered versions of the meter are also available. These versions offer additional options for serial communications and additional analog, pulse, frequency and alarm outputs. Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration accompanies every meter. FEATURES Mass flow measurement from a single instrument Optional steam energy flow measurement Integral 1,000 W platinum RTD for precise temperature measurement Optional integral pressure transducer for accurate pressure readings at the meter location DC loop powered operation Maintenance free non-moving parts design Wear resistant bluff body/sensor design Advanced signal processing algorithms ensure stable flow readings and reject noise. Easy-to-install meter arrives fully programmed and ready to use. Optional multi-analog output versions available. HART serial communication Optional BACnet MS/TP or MODBUS RTU RS485 serial communication GENERAL SPECIFICATIONS ACCURACY Steam and gases (Reynolds Number 10,000) Percent of reading accuracy to within: ± 1.0% for steam and gases (volumetric) ± 1.5% for steam and gases (mass) Repeatability: ± 0.2% Long term stability: ±0.2% over a period of 1 year Liquids ± 0.7% for liquids (volumetric) Repeatability: ± 0.2% Long term stability: ±0.2% over a period of 1 year Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) sales@onicon.com 02-15

2 EXIT SENSING METHOD Vortex shedding with integral piezoelectric sensors Integral 1,000 W platinum RTD (optional) provides instantaneous temperature Integral pressure transducer (optional) provides instantaneous pressure. OPERATING TEMPERATURE RANGE Ambient: -40 F (-40 C) to +185 F (+85 C) Process: -330 F (-200 C) to +500 F (+260 C) Optional high temperature limit +750 F (+400 C) MAXIMUM OPERATING PRESSURE Flange rating or 1500 psi (103 bar) PRESSURE LOSS loss varies with meter size and flow rate. Please contact ONICON for detailed information. CONNECTION TYPE NPT threads with Packing Gland 2" ANSI Class 150 Flange with Packing Gland 2" ANSI Class 300 Flange with Packing Gland MATERIALS Wetted Metal Parts Electronics Enclosure: 316L Stainless Steel Epoxy painted aluminum INPUT POWER OPTIONS Loop Power: VDC, 22 ma maximum current External DC Power: VDC, 300 ma maximum current Eternal AC power: VAC 50/60 Hz, 5W. maximum power ENCLOSURE NEMA 4X (IP66) DISPLAY 2-line, 16 character alphanumeric LCD with backlighting option. Standard saturated steam display menu provides: Mass Flow Rate, Temperature, (calculated), Mass Total and Alarms (if active). Optional remote mount transmitter version available (Standard cable length 50 ft., maximum 150 ft.) OUTPUT SIGNALS PROVIDED DC loop powered version Analog Rate: 2-wire, 4-20 ma, VDC, maximum loop resistance = RL ((V supply - 12 V) /.020 A) Totalization: 2-wire open collector scaled pulse, 50 ms duration, 5-36 VDC and 40 ma / 320 mw maximum Frequency: 2-wire open drain FET, 10 khz maximum frequency, 5-36 VDC and 40 ma / 200 mw maximum Digital: HART serial communications Optional Backlight Connection: Requires external VDC power supply, 35 ma maximum current Optional DC or AC powered version Analog Rate: Up to (3) 2-wire, 4-20 ma, VDC, maximum loop resistance = RL ((V supply - 12 V) /.020 A) Totalization: (1) 2-wire open collector scaled pulse, 50ms duration, 5-36 VDC and 40 ma / 320 mw maximum Frequency: (1) 2-wire open drain FET, 10 khz maximum frequency, 5-36 VDC and 40 ma / 200 mw maximum Alarm: Up to (3) opto-coupled relay alarm outputs Digital: HART serial communications Optional on DC or AC powered version BACnet MS/TP or MODBUS RTU RS485 serial communications in place of HART Specifications subject to change without notice. REMOTE MOUNT INSTALLATION 2.1 in 3.0 in 5.0 in 8.3 in 5.7 in 3.0 in REMOTE CABLE, 50 FT STANDARD LENGTH 5.0 in 0.6 in 2.8 in REMOTE ELECTRONICS OPTION AVAILABLE ON ALL MODELS.34 in DIA. U Bolt Provided F-2700 Series Insertion Vortex Flow Meter Catalog Sheet Page 2

3 EXIT STRAIGHT RUN REQUIREMENTS Insertion Vortex Flow Meter (for pipes 2 in diameter) PIPE RUN ECCENTRIC REDUCER UPSTREAM OPTIONAL FLOW STRAIGHTENER ECCENTRIC EXPANSION DOWNSTREAM PIPE RUN FLOW DIRECTION 2 DIAMETERS UPSTREAM STRAIGHT PIPE RUN TO FLOW STRAIGHTENER * MINIMUM UPSTREAM STRAIGHT PIPE RUN TO FIRST OBSTRUCTION MINIMUM DOWNSTREAM STRAIGHT PIPE RUN 5 DIAMETERS Obstruction Single bend preceded by 9 diameters of straight pipe * Upstream Straight Pipe Run Requirements Straight pipe run without flow straightener Straight pipe run to flow straightener 10 Dia NA Outflowing tee 10 Dia NA Pipe size reduction before meter 10 Dia NA Single bend preceded by 9 diameters of straight pipe 15 Dia 8 Dia Expansion before meter 20 Dia 8 Dia Multiple bends out of plane 30 Dia 13 Dia Partially open valve 30 Dia 13 Dia Control valve / P.R.V. 50 Dia 23 Dia F-2700 Series Insertion Vortex Flow Meter Catalog Sheet Page 3

4 FLOW METER OPERATING RANGES Insertion Meter Flow Rates for Saturated Steam Nominal diameter in inches and Saturated Steam Flow Specific Operating s Insertion Meter Flow Rates in lb/hr Nominal Diameter (in), Schedule (psig) Density (lb/ft 3 ) lbs / hr " " " " " Flow Rates for Water Rate Water and Flow Rates (GPM) Nominal Diameter (in) Min GPM Max GPM F-2700 Series Insertion Vortex Flow Meter Catalog Sheet Page 4

5 METER ORDERING INFORMATION Insertion Vortex Meter Codification = F-2700-ABC-DEFG A = Connection Type 0 = 2 Male NPT threads with retractor 1 = 2 ANSI class 150 flange with retractor 3 = 2 ANSI class 300 flange with retractor 6 = 2 ANSI class 600 flange with retractor 7 = 2 Male NPT threads without retractor ( 50psig maximum pressure) 8 = 2 ANSI class 150 flange without retractor ( 50psig maximum pressure) 9 = 2 ANSI class 300 flange without retractor ( 50psig maximum pressure) B = Integral or Remote Mount Transmitter 1 = Integral Mount 2 = Remote Mount C = Temperature / Compensation 0 = Integral temperature compensation 1 = Integral temperature & pressure sensor, 30 psia maximum 2 = Integral temperature & pressure sensor, 100 psia maximum 3 = Integral temperature & pressure sensor, 300 psia maximum 4 = Integral temperature & pressure sensor, 500 psia maximum 9 = None D = Input Power 0 = Loop powered (Only available with Output Signals option F=0) 1 = External VDC powered 2 = External VAC powered E = Output Signals 0 = 4-20mA output*, pulse output & frequency output 1 = 4-20mA output, pulse output & frequency output, alarm output & MODBUS 2 = 4-20mA output, pulse output & frequency output, alarm output & BACnet 3 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & MODBUS 4 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & BACnet 5 = (3) 4-20mA outputs*, (3) alarm outputs, (1) pulse output (1) frequency output 6 = 4-20mA output*, pulse output & frequency output, alarm output F = Operating Temperature 0 = 500 F 1 = 750 F G = Energy Meter 0 = None 1 = Gross energy meter 2 = Net energy meter (requires additional remote temperature sensor.) * Available with HART serial communications Remote Temperature Sensor and Thermowell Installation Kit (Required for Net Energy Meter) Part Number Description Remote Temperature Sensor, 1,000 Ohm 4-wire Class A Platinum RTD Remote Thermowell Kit for 1½" Welded Steel Pipe Remote Thermowell Kit for 2-5" Welded Steel Pipe Remote Thermowell Kit for 6-14" Welded Steel Pipe Note: Net energy meter requires 1 temperature sensor and 1 thermowell installation kit sized to pipe. F-2700 Series Insertion Vortex Flow Meter Catalog Sheet Page 5

6 EXIT EXIT INSERTION METER DIMENSIONS & WEIGHTS Retractor REMOVABLE Required RETRACTOR for Applications REQUIRED Over FOR 50 APPLICATIONS PSIG OVER 50 PSIG 8.0 in ( inmm) (203 mm) 5.0 in ( inmm) (127 mm) 3.0 in 3.0 (76 inmm) (76 mm) A A transducer transducer housing housing (empty on some (empty models) on some models) * Orientation Orientation lever lever 3/4" NPT 3/4" Conduit NPT Conduit entry entry Electronics Electronics enclosure enclosure clamp clamp Packing Packing gland gland 2 inch 2 inch Male 2 inch NPT B max. 2 male inch NPT Male NPT B max. male NPT Vortex Vortex sensor sensor head head *This dimension is the same for integral and remote mount meters. 2 inch 2 Mounting inch flange Mounting flange Depth marker Depth marker arrow arrow Stanchion Stanchion Scribe mark Scribe mark Insertion tool Insertion tool Upper retractor bracket Upper retractor bracket lock bolt lock (center) bolt Sensor (center) Sensor alignment alignment pointer pointer clamp nuts clamp nuts clamp bolts clamp bolts Packing gland nuts Packing (covered gland by stem nuts clamp) (covered Lower retractor by stem clamp) Lower bracket retractor bracket housing housing Mounting Option Standard Length Extended Length in (mm) A B A B Mounting Option in (mm) Standard Length Male NPT 40.5 (1029) 21.5 (546) 52.5 A(1334) 33.5 B(851) ANSI Packing Class Gland 150 Flange & Male NPT 40.5 (1029) 21.1 (536) 52.5 (1334) 40.5 (1029) 33.1 (841) 21.5 (546) ANSI Class 300 Flange 40.5 (1029) 21.1 (536) Packing Gland & ANSI Class 150 Flange 52.5 (1334) 40.5 (1029) 33.1 (841) 21.1 (536) Packing Gland & ANSI APPROXIMATE Class 300 Flange WEIGHT, LB (KG) 40.5 (1029) 21.1 (536) SL EL APPROXIMATE WEIGHT, LB (KG) NPT 16 (7.1) 17 (7.6) SL EL Class (9.4) NPT 22 (9.9) 16 (7.1) 17 (7.6) Class (11.3) 26 (11.8) Class (9.4) 22 (9.9) Add 11 LB (5 KG) for remote electronics Class (11.3) 26 (11.8) Add 11 LB (5 KG) for remote electronics Extended Len A 52.5 (1334) (1334) (1334) 33. Sensor head Sensor head F-2700 Series Insertion Vortex Flow Meter Catalog Sheet Page 6

7 FLOW STRAIGHTENER Gasket Thickness, Nominal Serrations show located under gasket, if provided Note: Dimension C indicates ID for serrations. Dim B Dim C Dim A # of holes - 35 Diameter Dim A Dim B Dim C Part # Each 2 (50mm) (80mm) (100mm) (150mm) (200mm) PRE-CUT GASKETS Pre-cut ⅛ gaskets for use with class 300 raised face flanges. Gaskets are suitable for use with water, inert gases and saturated steam up to 150 psig. For saturated steam applications above 150 psig, contact ONICON for assistance. Diameter Part # Each 2 (50mm) (80mm) (100mm) (150mm) (200mm) PRESSURE TRANSDUCER OPTIONS Full Scale Operating PSIa Overrange PSIa F-2700 Series Insertion Vortex Flow Meter Catalog Sheet Page 7

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

F-2500 SERIES VORTEX METER

F-2500 SERIES VORTEX METER F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

Vortex Flowmeter Model DVE

Vortex Flowmeter Model DVE Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in

More information

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VLM20 In-line Vortex Flowmeter

VLM20 In-line Vortex Flowmeter ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

The readings you need, right where you need them. AX Series Vortex Meters

The readings you need, right where you need them. AX Series Vortex Meters The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ

More information

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide FLOW AND ENERGY MEASUREMENT F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 www.onicon.com

More information

Vortex Flow Meter Model DVH

Vortex Flow Meter Model DVH Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400

More information

RIM20 Rotor Insertion Flowmeter

RIM20 Rotor Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid

More information

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C

More information

VORTEX IN-LINE FLOW METERS

VORTEX IN-LINE FLOW METERS VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting

More information

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter.   FEATURES DESCRIPTION Multivariable Mass Vortex Flow Meter FEATURES Mass and volumetric flow measurement of gas, liquid, and steam Multivariable outputs for five process parameters: mass flow rate volumetric flow rate temperature

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online... Multivariable Mass Vortex Flow Meter Features Volumetric or mass flow monitoring of gases, liquids and steam Smart electronics extends range down to a Reynolds number of 5000 Ideal for steam applications

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

Transmitting Transducer. Gas/Air Velocity Range:

Transmitting Transducer. Gas/Air Velocity Range: RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

Vortex Eggs Delta Flowmeter

Vortex Eggs Delta Flowmeter Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes

More information

Vortex Plate. Model VP General Specification. Product Features

Vortex Plate. Model VP General Specification. Product Features Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals

More information

VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters. Instruction Manual

VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters. Instruction Manual Table of Contents VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters Instruction Manual Document Number M-000-00010 Rev 8/2018 8475 W I-25 Frontage Rd Suite 300 Longmont, CO 80504

More information

Instruction Manual Vortex Flow Meter DVH / DVE

Instruction Manual Vortex Flow Meter DVH / DVE Instruction Manual Vortex Flow Meter DVH / DVE Customer Notice for Oxygen Service Unless you have specifically ordered Heinrichs` optional O 2 cleaning, this flow meter may not be fit for oxygen service.

More information

TURBINE FLOW METER SELECTION GUIDE

TURBINE FLOW METER SELECTION GUIDE TURBINE FLOW METER SELECTION GUIDE I. MODEL NUMBERING SYSTEM Format: F(B)-XX YY SERIES F-11 Single Turbine, Insertion Type (1¼" and larger pipes) F-12 Dual Turbine Insertion Type (2½" and larger pipes)

More information

240/241 Series Vortex Volumetric and Mass Flow Meters. Instruction Manual

240/241 Series Vortex Volumetric and Mass Flow Meters. Instruction Manual Sierra 240/241Series Instruction Manual Table of Contents 240/241 Series Vortex Volumetric and Mass Flow Meters Models: 240-V, VT, VTP, LP / 241-V, VT, VTP, LP, Cryogenic Instruction Manual Document Number

More information

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual Series M22/M23 Instruction Manual Table of Contents VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters Models M22-VT, M22-VTP, M23-VT, M23-VTP Instruction Manual Document

More information

DVH / DVE. Vortex Flow Meter. Instruction Manual. Page 1 of 102

DVH / DVE. Vortex Flow Meter. Instruction Manual. Page 1 of 102 Vortex Flow Meter DVH / DVE Instruction Manual Page 1 of 102 Contents 1 IDENTIFICATION... 5 1.1 Supplier / Manufacturer... 5 1.2 Producttype... 5 1.3 Issue date... 5 1.4 Version No.... 5 1.5 Tagging /

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual Table of Contents VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters Models M22-VT, M22-VTP, M23-VT, M23-VTP Instruction Manual Part Number IM-22-VT, VTP, IM-23-VT,VTP 04/05 8475 W-I25

More information

GE Sensing. PanaFlow MV. Vortex Flowmeter. User s Manual

GE Sensing. PanaFlow MV. Vortex Flowmeter. User s Manual GE Sensing PanaFlow MV Vortex Flowmeter User s Manual GE Sensing Panaflow MV Vortex Flowmeter User s Manual 910-279A June 2007 Warranty Each instrument manufactured by GE Sensing, Inc. is warranted to

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:

More information

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct MF200A Series Weather-Proof Thermal Mass Flow Meter for Pipe - Duct Feature & Application n Accuracy ±1.0% reading n Watch-dog software n Wide turn-down ratio 300 : 1 n Repeatability ±0.15% FS n 16 x 2

More information

Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters. Instruction Manual Series 24-HP Instruction Manual Table of Contents Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters Models 240-VT, 240-VTP, 241-VT, 241-VTP Instruction Manual Part Number: IM-24-HP,

More information

220 Series Innova-Flo o

220 Series Innova-Flo o Smart Vortex Flow Meter Features Volumetric flow monitoring of most gases, liquids and steam Smart electronics extends range down to a Reynolds number of 5000 Insertion style allows installation in any

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

SIGNET 7002 Vortex Flow Sensor ENGLISH

SIGNET 7002 Vortex Flow Sensor ENGLISH SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility

More information

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Installation and Operation Guide B Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control Accuracy: ±% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or Stainless

More information

RCM - Direct Reading Flowmeters

RCM - Direct Reading Flowmeters Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale

More information

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:

More information

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control

More information

Model 1000 Vortex Meter

Model 1000 Vortex Meter Model 1000 Vortex Meter Installation and Instruction Manual Table of Contents General Information... 1 1-1 General... 1 1-2 Principles of Operation... 1 1-3 Sensor Operation... 1 1-4 Calibration Factor...

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

F-5100 Insertion Thermal Mass Flow Meter Installation and Operation Guide

F-5100 Insertion Thermal Mass Flow Meter Installation and Operation Guide F-5100 Insertion Thermal Mass Flow Meter Installation and Operation Guide SAFETY INFORMATION This meter was calibrated at the factory before shipment. To ensure correct use of the meter, please read this

More information

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage

More information

Model 5000 Vortex Meter

Model 5000 Vortex Meter Model 5000 Vortex Meter Installation and Instruction Manual Table of Contents General Information... 1 1-1 General... 1 1-2 Principles of Operation... 1 1-3 Sensor Operation... 1 1-4 Calibration Factor...

More information

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flow Meters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 FLOW METER Wastewater Treatment Aeration Control Blower

More information

Product Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION

Product Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION VN2000 Flow Meters Compact Insertion Meter DESCRIPTION The VN2000 Compact Insertion Vortex Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

NC State University Design and Construction Guidelines Division 23 Energy Management

NC State University Design and Construction Guidelines Division 23 Energy Management 1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have

More information

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management

More information

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic

More information

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter The 10D1477 electrodeless ceramic lined wafer sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These

More information

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas

More information

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE VN2000 Flow Meters Hot Tap Insertion Meter DESCRIPTION The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow

More information

Hydro-Flow Model 3100

Hydro-Flow Model 3100 Hydro-Flow Model 3100 Installation and Operation Guide installation and operation guide Contents: Understanding Your Flow Meter... 1 Identifying Your Flow Meter...2 Installing Your Flow Meter...3,4 Making

More information

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE VN2000 Flow Meters Wafer Plate Inline Meter DESCRIPTION The VN2000 Wafer Plate Inline Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow range.

More information

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE VN2000 Flow Meters Hot Tap Insertion Meter DESCRIPTION The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow

More information

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279 Fax (951) 652-3078

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

imag 4700 SERIES FLANGED MAGMETER

imag 4700 SERIES FLANGED MAGMETER SERIES r (Remote Display) p Features Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated Right meter for Water & Wastewater Treatment Municipal

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2-

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available with optional MultiVariable output and temperature compensated mass flow for saturated steam. Available in wafer, flanged, dual, reducer

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

flow measurement solutions RIM10 series rotor insertion flowmeters

flow measurement solutions RIM10 series rotor insertion flowmeters flow measurement solutions RIM10 series rotor insertion flowmeters R I M 1 0 RIM10 series rotor insertion flowmeters Versatile enough for almost any challenge Spirax Sarco s RIM10 rotor insertion flowmeters

More information

Ultra Mag SUBMITTAL PACKAGE

Ultra Mag SUBMITTAL PACKAGE SUBMITTAL PACKAGE Date: McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 PHONE (951) 652-6811 TOLL FREE (800) 800-8804 FAX (951) 652-3078 www.mccrometer.com 3255 WEST STETSON AVENUE HEMET, CALIFORNIA

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

Ultrasonic Flow Meter Series Smart-IN US. Features. Description Features Series 7200 is single-board, self-contained and state-of -the-art ultrasonic flow meter. It has the notable characteristics of high precision, high reliability, high performance, low price etc..

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

M3500 Industrial Pressure Transmitter

M3500 Industrial Pressure Transmitter M3500 Industrial Pressure Transmitter The M3500 is a high accuracy industrial pressure transmitter featuring HART communications and a cast aluminum enclosure for indoor or outdoor use. Typical output

More information

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power

More information

SITRANS F X SITRANS FX300 3/355

SITRANS F X SITRANS FX300 3/355 Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure

More information