Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal
|
|
- Dennis Atkins
- 5 years ago
- Views:
Transcription
1 Positive displacement flow fitting for continuous and batch control High accuracy ± 0.5% 1/2 TO 4 (DN 15 to 100) INLINE Quarter Turn technology For highly viscous fluids Electronics for indication, monitoring, transmitting, On/Off control and batch control Type 8070 can be combined with Type 8025 Type 8023 Type Type 2712 (8630) PLC Flow transmitter Wall mounted or Panel mounted version 4 20 m output module PI Flow Controller Continuous TopControl System This positive displacement fitting is specially designed for flow measurement or batch control of highly viscous fluids like glue, honey or oil. This measuring element must be associated to an electronic module SE30, SE32, SE35 with hall sensor principle only, quickly and easily connected together by a Quarter Turn. The design of this fitting is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of measuring flow. Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of that design. The low pressure drop and high pressure rating makes it suitable for both gravity and pump (in line) applications. urkert Quarter Turn Technology General data Compatibility Materials of wetted parts ody Rotor Shaft Seal with electronic SE30, SE32, SE35 with Hall sensor principle luminium, Stainless steel (316L/1.4401) PPS, luminium, St. steel (316L/1.4401) Stainless steel FKM (EPDM or PTFE on request) Complete device data (fitting + electronic module) Pipe diameter Threaded process connection Flanged process connection Measuring range viscosity >5 cps viscosity <5 cps Medium temperature max. luminium body Stainless steel body Fluid pressure max. DN 15 DN 25 DN 40 / DN 50 DN 80 DN 100 Viscosity ccuracy Repeatability 1/2 to 4 (DN 15 to 100) 1/2 ; 1 ; 1 1/2 ; 2 ; 3 (G or NPT) 25; 40; 50; 80 or 100 mm DIN 16 flange 1 ; 1 1/2 ; 2 ; 3 or 4 NSI 150L flange 0.50 to 320 gpm (2 to 1200 l/min) 0.78 to 320 gpm (3 to 616 l/min) 176 F (80 C) 248 F (120 C) 800 PSI (55 bar) (threaded process connection) 800 PSI (55 bar) or fl anges rules where fi tted 260 PSI (18 bar) 175 PSI (12 bar) 145 PSI (10 bar) 1000 cps. max (higher on request) ±0.5% of Reading 0.03% of Reading Environment mbient temperature operating and storage 32 F up to 140 F (0 C up to +60 C) Standards and approvals Protection class IP66 (NEM 6) usa.com Page 1/6
2 Installation and operation The fitting can handle particle sizes up to 0.25 mm. To prevent damage from dirt or foreign matter, we strongly recommend the installation of a 60 mesh strainer as close as possible to the inlet side of the meter. The pipe must be filled with liquid and free from air bubbles. void air purge of the system. Correct Ensure the fitting is installed so that the rotor shafts are always in a horizontal position. Flow direction is marked by an arrow on the body. Correct Incorrect When fluid passes through the fitting, rotors turn. This rotation produces a measuring frequency in the associated hall sensor, which is proportional to the flow. Dimensions [mm] Threaded connection C DN Stainless steel luminium C D E E D Flanged connection J K C G NSI Flansch (beidseitiger) DIN Flansch (beidseitiger) E H F L D DN St. St. l. C D E F G H J K L Page 2/6
3 Ordering chart for fitting S070 DN Process connection Flow Range > 5 cps < 5cps 15 NPT 1/ g/min g/min luminium PPS FKM ody material (2-30 l/min) (3-25 l/min) Stainless steel Stainless steel FKM G 1/ g/min g/min luminium PPS FKM (2-30 l/min) (3-25 l/min) Stainless steel Stainless steel FKM NPT g/min g/min luminium PPS FKM (6-120 l/min) ( l/min) Stainless steel Stainless steel FKM NSI 150 L fl ange g/min g/min luminium PPS FKM (6-120 l/min) ( l/min) Stainless steel Stainless steel FKM G g/min g/min luminium PPS FKM (6-120 l/min) ( l/min) Stainless steel Stainless steel FKM mm DIN 16 fl ange g/min g/min luminium PPS FKM (6-120 l/min) ( l/min) Stainless steel Stainless steel FKM NPT 1 1/ g/min g/min luminium PPS FKM ( l/min) ( l/min) Stainless steel Stainless steel FKM /2 NSI 150 L fl ange g/min g/min luminium PPS FKM ( l/min) ( l/min) Stainless steel Stainless steel FKM G 1 1/ g/min g/min luminium PPS FKM ( l/min) ( l/min) Stainless steel Stainless steel FKM mm DIN 16 fl ange g/min g/min luminium PPS FKM ( l/min) ( l/min) Stainless steel Stainless steel FKM NPT g/min g/min luminium PPS FKM ( l/min) ( l/min) 2 NSI 150 L fl ange g/min g/min luminium PPS FKM ( l/min) ( l/min) Stainless steel Stainless steel FKM G l/min l/min luminium PPS FKM ( l/min) ( l/min) 50 mm DIN 16 fl ange l/min l/min luminium PPS FKM ( l/min) ( l/min) Stainless steel Stainless steel FKM NPT g/min g/min luminium luminium FKM NSI 150 L fl ange g/min g/min luminium luminium FKM G g/min g/min luminium luminium FKM mm DIN 16 fl ange g/min g/min luminium luminium FKM NSI 150 L fl ange g/min luminium luminium FKM ( l/min) 100 mm DIN 16 fl ange g/min luminium luminium FKM ( l/min) Rotor material Gasket Page 3/6
4 Ordering chart spare parts for fitting Type S070 Description [mm] Size [inch] Rotor DN 15 1/2 PPS Materials Stainless steel DN25 1 PPS Stainless steel DN40 1 1/2 PPS Stainless steel DN50 2 PPS Stainless steel Description [mm] Size [inch] O-ring DN 15 1/2 EPDM Transmitter electronics compact Type SE35 for S070 fitting Specifications Power supply Electrical connection Flow transmitter with 4-20m, pulsed output, 2 totalizers V DC Cable grommet plug Y Flow transmitter with 4-20m, pulsed output, 2 totalizers V DC Cable grommet entry (1 ea) Z Flow transmitter with 4-20m, pulsed output, 2 totalizers, 2 relays V DC Cable grommet entry (1 ea) S atch controller with 2 totalizers, 1 flow, 2 relays V DC Cable grommet entry (2 ea) J Flow transmitter with 4-020m, pulsed output, 2 totalizers VC Cable grommet entry (2 ea) E Flow transmitter with 4-20m, pulsed output, 2 totalizers, 2 relays VC Cable grommet entry (2 ea) G atch controller with 2 totalizers, 1 flow, 2 relays VC Cable grommet entry (2 ea) Sensor electronics compact Type SE35 for S070 fitting Specifications Power supply Cable supply Hall sensor VDC Hall sensor low power, only connectable to Types 8025, 8021, 8023 and SE34 from 8025/8023 DIN PG 9 DIN PG D E Standard output signal accessories Specifications Power supply Cable supply Materials FKM DN25 1 EPDM FKM DN40 1 1/2 EPDM FKM DN50 2 EPDM FKM Calibrated pulse output module Type VDC 1x PG P 4-20m output module Type VDC 1x PG V Control unit for 4-20m output module Type VDC None X Page 4/6
5 Ordering chart for fitting S070 SE32 display and electronic for S070 fitting Voltage supply Input signal Output signal * NPN US08572 PNP US08571 NPN and PNP US08570 Relay US VDC 4-20m 1) Relay US08568 Si us SI SI + relay US VDC 4-20m 1) 4-20m 2) + relay US ) Ext. set point 2) Process value * Plugs included with part number Page 5/6
6 Interconnection possibilities with the sensor Type S070 Fitting Sensor Converter modules Compact electronic Remote electronics modules Type 8025 Transmitter / atch controller Wall-mounted or panel-mounted 4-20 m output Pulse output Type 8072* Switch 4-20 m output Transistor output 4-20 m input (external setpoint) Type 8023 lind transmitter 4-20 m output Type 8034 Indicator Panel-mounted only Type 8075* Transmitter / atch controller 4-20 m output Pulse output Type S070 INLINE fitting Type 8021 Pulse divider Pulse output Type 8032 Switch/Transmitter Wall-mounted Intrinsic safety barrier Type SE30Ex 2-wire current modulation according to NMUR or NPN/PNP output Type 8070* Frequency output * Use only version with Hll transducer In case of special application conditions, We reserve the right to make technical 0602/2_US-en please consult for advice. changes without notice. Page 6/6
Positive displacement flowmeter for continuous flow measurement
8070 Positive displacement flowmeter for continuous flow measurement High accuracy Medium with high viscosity Mounting and dismounting of the electronics by a quarter-turn Connection to Bürkert devices
More informationPositive displacement flowmeter
Positive displacement flowmeter Configurable outputs: one or two transistor output(s) and single or dual 4...20 ma current output(s) Removable backlit display of flow rate and/or 2 two totalized volumes
More informationPositive displacement batch controller
8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:
More informationFPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters
FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) SERIES LOW Flow Positive Displacement Flowmeters To the owner: Please take a few minutes to read through the manual
More informationINLINE fitting with paddle-wheel for flow measurement
INLINE fitting with paddlewheel for flow measurement 06 to 65 Closed pipe system, i.e. sensor inside fitting Quarterturn technology Type can be combined with... Electronics available for Indication, Monitoring,
More informationINLINE fitting with paddle-wheel for flow measurement
ININE fitting with paddlewheel for flow measurement Type can be combined with... N 06 to N 65 Closed pipe system, i.e. sensor inside fitting Quarterturn technology Electronics available for Indication,
More informationFPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters
FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters To the owner: Thank you for purchasing an OMEGA FPD Series Flowmeter. Please take a few minutes to read through the manual before installing
More informationPaddle-wheel flow controller with optical principle for On/Off control
Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )
INST-075M_R4 11/2012 OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationdisplay on the wall or in a panel away from the inline sensor SE30 for easy meter reading.
Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )
INST-012M_R4 11/2012 OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationOMP Positive Displacement Flowmeters
Flow Ranges From 0.53 to 26 GPH Through 4 to 132 GPH Handles Viscosities to 1,000,000 cps Handles Viscosities to 1,000,000 cps Low Head Loss Oval Gear Design OMP Series Medium & High Flow Meters OMP-1
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾
INST-019P_R4 11/2012 OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾ INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationMX-SERIES OVAL GEAR FLOW METERS
Data Sheet MX-SERIES OVAL GEAR FLOW METERS Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com MX-Series Oval Gear Flow Meters Features and Advantages P From ¼ DN8 at 0.5LPH to 4 DN100
More informationmacnaught flow measurement
macnaught flow measurement fuel and oil meters macnaught.com.au flow meters fuel and oil macnaught flow measurement The F range of oval gear fuel and oil meters from Macnaught are positive displacement
More informationOMP POSITIVE DISPLACEMENT FLOWMETERS
OMP POSITIVE DISPLACEMENT FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Flow Ranges from 0.53 to 26 GPH to 4 to 92 GPM Handles Viscosities to 1,000,000 cps Pressure Ratings
More informationINSERTION flowmeter with paddle wheel, ELEMENT design
INSERTION flowmeter with paddle wheel, design Up to PN, size of measurement pipes: DN to DN400 Configurable outputs: one or two transistor output(s) and single or dual 4... ma analog output(s) Removable
More informationOM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters
Oval Gear Meters OVAL GEAR METERS OM Series Oval Gear Meters are designed for low flow and high accuracy. OM Series Meters are great for viscous fluids. Units are available with from either a Reed Switch
More informationFPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters
FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters To the owner: Please take a few minutes to read through the manual before installing
More informationRUN ACCUM. TOTAL STOP BAT LOW HIGH
TURBOPULSE TURBINE FLOWMETER INSTRUCTION MANUAL gal RUN ACCUM. TOTAL STOP BAT LOW HIGH RESET > PROGRAM ENTER ACCUM TOTAL ^ RATE TOTAL TP050 TABLE OF CONTENTS 1. INTRODUCTION Overview 1 1.1 Model number
More informationmacnaught flow measurement
macnaught flow measurement industrial flow meters macnaught.com.au flow meters m-series industrial macnaught flow measurement The M & MH range from Macnaught are positive displacement oval gear flowmeters
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )
012 Mech 07.11 OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationPOSITIVE DISPLACEMENT FLOW METERS
POSITIVE DISPLACEMENT FLOW METERS ABOUT MACNAUGHT Macnaught Pty Ltd is a privately owned manufacturing company based in Australia, established in 1948. Macnaught s experience in Positive Displacement Flow
More informationFLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE
FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor FlowX3 F3.20 is a paddlewheel flow sensor suitable for system at high pressure and at critical temperature. F3.20 is designed for use with every kind
More informationINLINE sensor-fitting with paddle wheel for flow measurement
INLINE sensorfitting with paddle wheel for flow measurement Type S030 can be combined for... 06 to 65 Closed pipe system, i.e. sensor included in fitting Quarterturn technology Transmitter available also
More informationPOSITIVE DISPLACEMENT FLOW METERS
POSITIVE DISPLACEMENT FLOW METERS ABOUT MACNAUGHT Macnaught Pty Ltd is a privately owned manufacturing company based in Australia, established in 1948. Macnaught s experience in Positive Displacement Flow
More informationPositive Displacement Flowmeters GM020 series instruction manual
ACCURATE FLOWMETERS & INSTRUMENTATION PVT. LTD. Positive Displacement Flowmeters GM020 series instruction manual GM020 Pulse Meter From serial No. CXXXX Accurate Flowmeters & Instrumentation Pvt. Ltd.
More informationG2 Industrial Grade Meters
G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine
More informationDPT TARGET TYPE FLOWMETERS
DPT TARGET TYPE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control S3 Patented Target/Leaf-Spring Design Minimal Wear Components 1.5-8 to 225-500 GPM Water Line Sizes 3/8 to 3" Wide
More informationINSERTION fitting for flow measurement or analysis
INSERTION fitting for flow measurement or analysis Type S020 can be combined with... Universal fitting for INSERTION sensors, transmitters, batch controllers in pure, aggressive or contamined liquids arge
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )
INST-006/009P_R9 06/2015 OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ ) INSTRUCTION MANUAL F Serial Meters To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this
More informationSolenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections
/-way Diaphragm Valve with plastic body, pneumatically operated, 1/ 3 with true union 3 with fl ange pplications with aggressive media Flow optimised body with zero dead volume Self draining installation
More informationOperating Instructions for Oval Wheel Flowmeter. Model: DOC
Operating Instructions for Oval Wheel Flowmeter Model: DOC We don t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products. The document
More informationIM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL
IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist you in the operation
More informationMX06 - MX100 OVAL GEAR FLOWMETER SERIES
MXL-INST Rev 7 04/2016 MX06 - MX100 OVAL GEAR FLOWMETER SERIES INSTRUCTION MANUAL To the Owner Please read and retain this instruction manual to assist you in the operation and maintenance of this product.
More informationmacnaught flow measurement
macnaught flow measurement solvent flow meters macnaught.com.au flow meters solvent macnaught flow measurement The "S" range of oval gear fuel and oil meters from Macnaught are positive displacement oval
More informationPositive Displacement Flowmeters GM020 series instruction manual
MS244G 0603 0003 Positive Displacement Flowmeters GM020 series instruction manual GM020 Pulse Meter From serial No. CXXXX To the owner Thank you for purchasing a GPI GM Series Flow Meter. Please take a
More informationInsertion magnetic inductive flowmeter
Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1
025 Puls 07.11 OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1 INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist you
More informationMX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS
MXEX-INST Rev 9.0 04/2016 MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS INSTRUCTION MANUAL To the Owner Page 1 of 33 index Installation Pre-installation checks. Page 3 Operating
More informationAxial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25
Installation Instruction Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25 Table of contents Page 1 Function of Turbotron 1 2 Safety instructions 2 3 Important notes and requirements
More informationIndustrial OG meter series IOG Inline and flanged oval gear meter
Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Industrial OG meter series IOG Inline and flanged oval
More informationTurbotron // VTH15, VTM15, VTP15, VTI15
1 Flow Measuring Turbine flow sensors Turbotron // VTH15, VTM15, VTP15, VTI15 VTH15 BEST SELLER VTM15 Your advantages Series VTH15 VTM15 Cost optimized version For medium temperature up to 120 C Type VTH15
More informationOM004, OM006 & OM008 Oval Gear Meter
OM SERIES OM004, OM006 & OM008 Oval Gear Meter OM004 (1/8"), OM006 (1/4") and OM008 (3/8") Oval Gear Meters ACCURACY: ±1.0% OF READING Select Your Body Material: Aluminum or Stainless Steel The OM Small
More informationPositive Displacement Flowmeters GM007 series instruction manual
MS499G 0603 0003 Positive Displacement Flowmeters GM007 series instruction manual GM007 Pulse Meter From serial No. CXXXX To the owner Thank you for purchasing a GPI GM GPI by telephone or fax.] Series
More informationInstallation & Operation Manual
MFM/M0 Inlet/Outlet: (F) IN-LINE FLOW METER Installation & Operation Manual IMPORTANT! This manual contains important warnings and other information. READ AND KEEP FOR REFERENCE. S70, Rev A January 00
More informationFlow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue
Flow Meters & Instruments Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments Technical Catalogue PDF Published October 19, 2017 flow sensors Type F3.01 Direct Mount Flow Sensors
More informationInductive conductivity meter
Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values
More informationPOSITIVE DISPLACEMENT FLOWMETERS
MS589 0409 00 POSITIVE DISPLACEMENT FLOWMETERS M80 SERIES INSTRUCTION MANUAL M80 Pulse; Standard LCD; Deluxe LCD; From serial No.CXXXX TO THE OWNER Please take a few minutes to read through this manual
More informationINSTRUCTION MANUAL MN7 series
Badger Meter Europa GmbH INSTRUCTION MANUAL MN7 series September 2001 Version MN7-09/01-e Content Content Page 1. To the owner 1 2. Important information 1 3. Installation 3 4. Operation 4 5. Electrical
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications
INST-CR025P_R1 012/2011 OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1 Type CR for Corrosive Applications INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and
More information2/2 way Globe Control Valve, threaded connection, 3/8" 3"
2/2 way Globe Control Valve, threaded connection, 3/8" 3" Complete Burkert system using Type 2712 with TopControl 8630 New generation with interchangeable trims, 3 to 5 Cvs value per connection port Excellent
More informationPOSITIVE DISPLACEMENT FLOWMETER
Includes models IM019E-01 IM019E-02 IM019E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction
More informationMagnetic Paddle Flow Sensor/Switch for Easy On/Off Control
Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control INLINE Quarter-Turn ON/OFF Control System for Monitoring and Switching Mechanical adjustment of set point No contact to Fluid thanks to INLINE
More informationDTK. OEM Pelton Wheel Flow Sensor
OEM Pelton Wheel Flow Sensor measuring monitoring analyzing DTK Measuring Range: 0.8...9.5 to 6...90 GPH Water Measures Clear or Opaque Liquids Stainless Steel Body Pelton Wheel Design Requires No Inlet
More information25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS
TS- Rev. B Type S lowmeters 1, 1 1 2 & 2 mm (1 in), mm (1-1/2 in) & mm (2 in) TYPE S LOWMETERS WITH MODEL 7 AND 8 SERIES REGISTERS 1-1/2" Type S with Model 7 Register SPECIICATIONS 1" Type S with Model
More informationG2 SERIES INDUSTRIAL GRADE METERS
Industrial Grade Meters INDUSTRIAL GRADE METERS The unique modular approach of the Industrial Grade Meter line allows you to design a meter to match your specific application. Turbine choice depends on
More informationPositive Displacement Flowmeters GM50 series instruction manual
Positive Displacement Flowmeters GM50 series instruction manual GM50 Pulse GM50 Standard LCD G540 Deluxe LCD From serial No. CXXXX MS244G 0899 0001 To the owner means the GM Series flow meter is suitable
More informationTYPE MP OSCILLATING PISTON FLOWMETER
TS-150 (G) TYPE MP OSCILLATING PISTON FLOWMETER Flow Rates of 3.8 to 1,140 Liters/Min. (1 to 300 gpm) Accuracy of ±0.5% of Rate ±0.1% Repeatability Magnetically Coupled Output Shaft Proven Reliable Oscillating
More information2/2 way Globe Control Valve, flange connection, 1/2" 4"
2/2 way Globe Control Valve, flange connection, 1/2" 4" Complete Burkert system using Type 2712 with TopControl 8630 New generation with interchangeable trims, 3 to 5 Cvs value per connection port Excellent
More informationNTD. Volumetric flow meters with IP-55 or EExd protection. Nuevas Técnicas de Dispersión, S.L.
Nuevas Técnicas de Dispersión, S.L. Pol. Ind. La Esperanza, C/Comunidad de Murcia, 152 12400 Segorbe (Castellón) España Tel. +34 964714032 - info@ntdmaquinaria.com www.ntdmaquinaria.com NTD Volumetric
More informationPSF50 Paddle flow switch
Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up
More informationThe experts in fluid technology
MS85 1005 0007 The experts in fluid technology Positive Displacement Flowmeters M10 series instruction manual M10 Mechanical meter From serial No. CXXXX To the owner Please take a few minutes to read thorugh
More informationThe experts in fluid handling
The experts in fluid handling Positive Displacement Flowmeters M50 series instruction manual M50 Pulse M50 Standard LCD M50 Deluxe LCD From serial No. CXXXX MS244 1298 0001 To the owner Thank you for purchasing
More informationOperating Instruction for Flowmonitor. Model: DF-WM
Operating Instruction for Flowmonitor Model: DF-WM 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 5 6. Mechanical Connection...
More informationPOSITIVE DISPLACEMENT FLOWMETERS
MS345BR 0408 0001 POSITIVE DISPLACEMENT FLOWMETERS M4 BRONZE SERIES INSTRUCTION MANUAL M4 Pulse; M4 Standard LCD; M4 Deluxe LCD; From serial No.CXXXX TO THE OWNER Please take a few minutes to read through
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )
012 Puls 07.11 OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationINDUSTRIAL METER CATALOG version seven
INDUSTRIAL METER CATALOG version seven TABLE OF CONTENTS G Series Precision Meters... Build-Your-Own... 4 G Series Meter Number Reference... 5 Stainless Steel GBT, GIT & GNT... 6 Stainless Steel GBP, GIP
More informationInline Paddle Wheel Flow Switch
Inline addle Wheel Flow Switch Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type can be combined with... Valve Alarm
More informationFLOWX3 F3.60M.S Insertion Magmeter
FLOWX3 F3.60M.S Insertion Magmeter The FLOWX3 F3.60M.S Insertion Magmeters are suitable to measure flowrate in both metal and thermoplastic pipelines. No moving mechanical parts and the high quality materials
More informationMODEL MX75 3 OVAL GEAR FLOWMETER
Installation & Maintenance Instructions MODEL MX75 3 OVAL GEAR FLOWMETER Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com MXL-INST75 Rev 1 06/2013 MODEL MX75 3 OVAL GEAR FLOWMETER
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationPositive Displacement Flowmeters GM515 series instruction manual
MS103G 0603 0004 Positive Displacement Flowmeters GM515 series instruction manual GM515 Mechanical meter From serial No. CXXXX To the owner Please take a few minutes to read thorugh this manual before
More informationDRT. Ring Piston Flow Meter. for low/high Viscous Liquids
Ring Piston Flow Meter for low/high Viscous Liquids measuring monitoring analysing DRT Measuring range: 0.2... 10 L/min to 12... 330 L/min Viscosity range: low viscous to high viscous liquids Accuracy:
More informationA Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >
Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation Guided-wave
More informationSIGNET 7002 Vortex Flow Sensor ENGLISH
SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility
More informationFluxi 2000/TZ Turbine Gas Meter
Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The
More informationFlow. Oval Wheel Flowmeter Model DOE
Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DOE Measuring range: 0.5 36 l/h und 1 40 l/min Viscosity range: 1 1000 cp Accuracy: ±1% of reading Material: stainless
More informationThe experts in fluid technology
MS65BR 0302 0001 The experts in fluid technology Positive Displacement Flowmeters M40 Bronze series instruction manual M40 Pulse M40 Standard LCD M40 Deluxe LCD From serial No. CXXXX To the owner Thank
More informationInductive conductivity meter
Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct
More informationflow x3 flow monitoring
flow x3 flow monitoring The FlowX3 System includes a complete range of paddle wheel flow sensors, instruments and sensor installation fittings. Also included are insertion type electromagnetic flow transmitters.
More informationThe experts in fluid technology
MS489FA 1002 0001 The experts in fluid technology Positive Displacement Flowmeters M4 Encoder series instruction manual M4 Encoder series meter From serial No. CXXXX To the owner Please take a few minutes
More information2/2- or 3/2-way- Rocker Solenoid Valve
2/2- or /2-way- Rocker Solenoid Valve Direct acting Hermetic isolation of fluid 0 145 SI 1) DN 2 mm Type 6128 can be combined with... Sub-base, threaded port 22mm width per station Type 2507 Cable lug
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationCONTOIL VZFA/VZOA , versions for higher requirements / applications
CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing
More informationVHS... Screw Flow Meter
Member of the Group VHS... Screw Flow Meter The normal transmitter with block plug already has a push pull output to serve all NPN or PNP Inputs. It supplies a square wave signal. Those transducers are
More informationFlow. Oval Wheel Flowmeter Model DON
Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DON OO Measuring range: 0.5 36 l/h und 150 2500 l/min OO Viscosity range: 0 1000 cp (higher on request) OO Accuracy:
More informationTechnical Data. Series Oval Flowmeter. Model 9400
Technical Data Series Oval Flowmeter Model 9400 General The Brodie 9400 Series Oval Flowmeters, Models 9402 through 9459 (sizes 1/2-3 ), are mechanical, positive displacement meters designed for use in
More informationI N S T R U C T I O N M A N U A L
I N S T R U C T I O N M A N U A L Oval Gear Positive Displacement Mechanical Flowmeters Models: 3 (080), 3 (080E), 4 (100), 4 (100E) NSW TEL: (02) 9939 0711 FAX: (02) 9939 0411 QLD/PNG TEL: (07) 3204 9166
More informationIndustrial Meter Catalog
Industrial Meter Catalog SEE INSIDE FOR THESE NEW PRODUCTS: GBM Series Mini Batcher... page 66 LM50M Mechanical Lube Meter... page 52 TM Digital Pulse Meter... page 53 VERSION 6 2008 888-996-3837 www.gpi.net
More informationM SERIES Multi-Jet Cold Water Meter
M SERIES Multi-Jet Cold Water Meter /4 1 1-1/2" 2" Maximum Flow GPM 0 0 1 Minimum Flow GPM.2.7 1. 2.0 Maximum Operating Pressure 0 psi Maximum Operating Temperature F ( C) Also Available in Hot Water Applications
More informationIndex Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3
09-10 LEFLSFX10 Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3 F9.60M Insertion Magmeter with display
More informationINDUSTRIAL DYNAMICS CO
TS-150 Rev. B MP Oscillating Piston Flowmeter: 12.7 mm (1/2" Type MP) 25.4 mm (1" Type MP) 50.8 mm (2" Type MP) 76.2 mm (3" Type MP) TYPE MP OSCILLATING PISTON FLOWMETER 2 " Type MP with 800 Series Register,
More informationConductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands
Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationNessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT
Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT Valve program for small and medium flows: VDHT 3/8 E 2/2 VDHT 1/2 E 2/2 VDHT 3/8 EA 2/2 VDHT 1/2 EA 2/2 Valve program
More information