BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual
|
|
- Ross Wilcox
- 5 years ago
- Views:
Transcription
1 BIN & SEN Annular Pitot Tube Flow Meter Form: 1-PTT-UM-349 (December 212) Installation & Operation Manual
2 Installation Instructions 1. The primary station can be installed in any position on vertical or horizontal lines. However for best result, on Horizontal liquid lines where the risk of air/gas entrapment in the meter tubing is prevalent, install the element with the head under the horizontal centerline. For Horizontal Air or Gas lines the head should be above the center line to prevent condensation. 2. Leave the protective caps in place to protect the valves against construction debris, dust, paint, etc. Close the valves after installation to prevent leakage on start-up. 3. For pipes 2" to 6". A) Pipes 2", 2-1/2", 3", 3-1/2" and 4", drill a 3/8" hole into pipe. B) Pipes 5" and 6" drill a 7/16" hole. C) Weld the coupling to the pipe in line with the hole. D) Pass the probe through the packing gland and insert it into the pipe through the coupling. Tighten hex nut to the coupling. E) Push the probe until it touches the opposite side of the pipe and tighten hex nut of the packing gland. 4. For pipes 8" to 24" -with double support. A) Pipes measuring 8" and 1" - Drill a 1/2" hole on side where reading will be taken and 13/32" on other side. Pipe measuring 12" - Drill a 5/8" hole on side where reading will be taken and 17/32" on other side. Pipe measuring 14" and 16"- Drill a 7/8" hole on side where reading will be taken and 25/32" on other side. Pipe measuring 18", 2" and 24"- Drill a 1-1/8" hole on side where reading will be taken and 1-1/16" on other side. B) Weld a coupling to the pipe in line with the hole making sure it is in line with opposite hole. C) Pass the probe through the packing gland and insert it into the pipe through the coupling. Tighten hex nut to the coupling. D) Push the probe through the pipe until it passes through opposite hole to insure alignment. E) Withdraw probe and weld other coupling to the pipe. F) Push the probe through the packing gland until it enters other hole and is flush with outside wall of the pipe and tighten hex nut of the packing gland. G) Install the plug into the coupling. Page 2 Form 1-PTT-UM /12
3 FLOW FLOW STRAIGHTENING VANE STRAIGHTENING VANE Form 1-PTT-UM /12 Page 3
4 ANNULAR ROUND: BIN NOMINAL PIPE SIZE - SCHED. 4. (For other sizes consult factory).5".75" 1" 1.25" 1.5" 2" 2.5" 3" 4" 5" 6" 8" 1" 12" 14" 16" 18" 2" 24" 2 3 P INCHES OF H2O WATER 6 F SCH. 4 PIPE USGPM Page 4 Form 1-PTT-UM /12
5 NOMINAL PIPE SIZE ANNULAR ROUND: BIN ".75" 1" 1.25" 1.5" 2" 2.5" 3" 4" 5" 6" 8" 1" 12" 14" 16" 18" 2" 24" 2 3 P INCHES OF H2O AIR, 1 PSIG, 7 F SCFM Form 1-PTT-UM /12 Page 5
6 NOMINAL PIPE SIZE ANNULAR ROUND: BIN ".75" 1" 1.25" 1.5" 2" 2.5" 3" 4" 5" 6" 8" 1" 12" 14" 16" 18" 2" 24" 2 3 P INCHES OF H2O AIR, 14.7 PSIA, 7 F SCFM Page 6 Form 1-PTT-UM /12
7 Badger Meter Warranty BIN & SEN Annular Pitot Tube PRODUCTS COVERED The Badger Meter warranty shall apply to the Preso BIN & SEN Annular Pitot Tube Flow Meter ( Product ). MATERIALS AND WORKMANSHIP Badger Meter warrants the Product to be free from defects in materials and workmanship for a period of 12 months from the original purchase date. PRODUCT RETURNS Product failures must be proven and verified to the satisfaction of Badger Meter. The Badger Meter obligation hereunder shall be limited to such repair and replacement and shall be conditioned upon Badger Meter receiving written notice of any asserted defect within 1 (ten) days after its discovery. If the defect arises and a valid claim is received within the Warranty Period, at its option, Badger Meter will either (1) exchange the Product with a new, used or refurbished Product that is at least functionally equivalent to the original Product, or (2) refund the purchase price of the Product. DO NOT RETURN ANY PRODUCT UNTIL YOU HAVE CALLED THE BADGER METER CUSTOMER SERVICE DEPARTMENT AND OBTAINED A RETURN AUTHORIZATION. Product returns must be shipped by the Customer prepaid F.O.B. to the nearest Badger Meter factory or distribution center. The Customer shall be responsible for all direct and indirect costs associated with removing the original Product and reinstalling the repaired or replacement Product. A replacement Product assumes the remaining warranty of the original Product or ninety (9) days from the date of replacement, whichever provides longer coverage. LIMITS OF LIABILITY This warranty shall not apply to any Product repaired or altered by any Product other than Badger Meter. The foregoing warranty applies only to the extent that the Product is installed, serviced and operated strictly in accordance with Badger Meter instructions. The warranty shall not apply and shall be void with respect to a Product exposed to conditions other than those detailed in applicable technical literature and Installation and Operation Manuals (IOMs) or which have been subject to vandalism, negligence, accident, acts of God, improper installation, operation or repair, alteration, or other circumstances which are beyond the reasonable control of Badger Meter. With respect to products not manufactured by Badger Meter, the warranty obligations of Badger Meter shall in all respects conform and be limited to the warranty extended to Badger Meter by the supplier. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES WHATSOEVER, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (except warranties of title). Any description of a Product, whether in writing or made orally by Badger Meter or its agents, specifications, samples, models, bulletins, drawings, diagrams, engineering sheets or similar materials used in connection with any Customer s order are for the sole purpose of identifying the Product and shall not be construed as an express warranty. Any suggestions by Badger Meter or its agents regarding use, application or suitability of the Product shall not be construed as an express warranty unless confirmed to be such, in writing, by Badger Meter. EXCLUSION OF CONSEQUENTIAL DAMAGES AND DISCLAIMER OF OTHER LIABILITY Badger Meter liability with respect to breaches of the foregoing warranty shall be limited as stated herein. Badger Meter liability shall in no event exceed the contract price. BADGER METER SHALL NOT BE SUBJECT TO AND DISCLAIMS: (1) ANY OTHER OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR OF WARRANTY, (2) ANY OBLIGATIONS WHATSOEVER ARISING FROM TORT CLAIMS (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR ARISING UNDER OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD OR SERVICES RENDERED BY BADGER METER, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATING THERETO, AND (3) ALL CONSEQUENTIAL, INCIDENTAL AND CONTINGENT DAMAGES WHATSOEVER. 1-PTT-UM /12 Badger Meter Warranty
8 Trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. 212 Badger Meter, Inc. All rights reserved. Phone: Fax: The Americas Badger Meter 4545 West Brown Deer Rd PO Box Milwaukee, WI México Badger Meter de las Americas, S.A. de C.V. Pedro Luis Ogazón N 32 Esq. Angelina N 24 Colonia Guadalupe Inn CP 15 México, DF México Europe, Middle East and Africa Badger Meter Europa GmbH Nurtinger Str Neuffen Germany Czech Republic Badger Meter Czech Republic s.r.o. Maříkova 282/ Brno, Czech Republic Slovakia Badger Meter Slovakia s.r.o. Racianska 19/B Bratislava, Slovakia Asia Pacific Badger Meter 8 Marine Parade Rd 21-4 Parkway Parade Singapore China Badger Meter Rm 51, N 11 Longyue Apartment N 18 Longjin Rd, Jiuting Songjiang District Shanghai, China
Model 200 Multi-Jet Flow Meter. 02-PDM-UM (July 2012) Installation & Operation Manual
Model 200 Multi-Jet Flow Meter 02-PDM-UM-00109 (July 2012) Installation & Operation Manual TABLE OF CONTENTS Introduction...3 Operating Principle...3 Specifications...4 Operating Limitations...5 Installation
More informationParts List. Recordall Turbo Series Meters
Recordall Turbo Series Meters Models 160 (1-1/ in.), 00 ( in.), 450 (3 in.), 1000 (4 in.), 000 (6 in.), 3500 (8 in.), 5500 (10 in.), 600 (1 in.) Models without Integral Strainers, Sizes 1-1/ 1 in. Models
More informationProduct Data Sheet. Industrial Oval Gear. Inline and Flanged Meters, 1/2", 3/4", 1", 1" HF, 1-1/2", 2", 3" DESCRIPTION OPERATING PRINCIPLE
Industrial Oval Gear Inline and Flanged Meters, 1/2", 3/4", 1", 1" HF, 1-1/2", 2", 3" DESCRIPTION The Badger Meter Industrial Oval Gear Meter, Model IOG is a modular flow meter design, economical yet highly
More informationProduct Data Sheet DESCRIPTION
Turbo Series Meters Models 16 (11/2"), 2 (2"), 4 (3"), (4"), 2 (6"), 3 (8"), ("), & 62 (12"); NSF/ANSI Standards 61 and 372 Certified DESCRIPTION Turbo Series meters meet or exceed the most recent revision
More informationControl Valves. Type HP-10, 10,000 PSI. User Manual. RCV-UM EN-01 (August 2014)
Control Valves Type HP-10, 10,000 PSI RCV-UM-01034-EN-01 () User Manual Control Valves Type HP-10, 10,000 PSI Page ii User Manual CONTENTS Overview...........................................................................
More informationProduct Data Sheet DESCRIPTION
Turbo Series Meters Models 16 (11/), 2 (), 4 (3 in.), (4 in.), 2 (6 in.), 3 (8 in.), ( in.) and 62 (1) NSF/ANSI Standards 61 and 372 Certified DESCRIPTION Turbo Series meters meet or exceed the most recent
More informationUser Manual. Ellipse Pitot Tube Meter. PFA Fire Pump System. PTT-UM EN-03 (March 2017) 2500 GPM 3000 F M
Ellipse Pitot Tube Meter PFA Fire Pump System 500 GPM 3000 000 3500 1500 1000 PFA-XXX X inch 50 SWP X/XX S/N AXXXXXXX 4000 METERS PTT-UM-0053-EN-03 () User Manual Ellipse Pitot Tube Meter, PFA Fire Pump
More informationVariable Area Flow Meters and Flow Switches. Easy-to-Use and Reliable Flow Measurement.
Variable Area and Flow Switches Easy-to-Use and Reliable Flow Measurement. Variable Area and Flow Switches The Hedland product line features over 15,000 inline, variable area flow meters to measure oil,
More informationProduct Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8", 5/8" x 3/4", 3/4" & 1" NSF/ANSI Standards 61 and 372 Certified
Recordall Disc Meters LeadFree Bronze Alloy, Sizes /8", /8" x 3/4", 3/4" & " NSF/ANSI Standards 6 and 372 Certified LP /8", /8" 3/4" 2 /8", /8" 3/4" 3 3/4" " 7 " DESCRIPTION The Recordall Disc Series meters
More informationProduct Data Sheet. Recordall Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass DESCRIPTION
Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass UL Certified & FM Standard Approved for Fire Service Applications NSF/ANSI Standards and Certified DESCIPTION Fire Series assemblies
More informationProduct Data Sheet. Recordall Fire Series Assembly (FSAA) Cold Water Meter & Strainer with Turbine Bypass DESCRIPTION
Fire Series Assembly (FSAA) Cold Water Meter & Strainer with Turbine Bypass UL Certified & FM Standard Approved for Fire Service Applications NSF/ANSI Standards and Certified DESCIPTION Fire Series assemblies
More informationApplication Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.
Chemical Compatibility Chart 6 Stainless Acetic Acid Acetone Acetylene Acidic Mine Water Acrylonitrile Ammonium Chloride Ammonium Hydroxide Ammonium Sulfate Ammonium Thio-Sulfate Anhydrous Ammonia Anhydrous
More informationProduct Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY
DESCRIPTION Flow Sensors Insert Style Flow Sensors SDI Series The Data Industrial SDI Series insert flow sensors from Badger Meter offer accurate liquid flow measurement in closed pipe systems in an easy
More informationProduct Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION
VN2000 Flow Meters Compact Insertion Meter DESCRIPTION The VN2000 Compact Insertion Vortex Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow
More informationProduct Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE
VN2000 Flow Meters Wafer Plate Inline Meter DESCRIPTION The VN2000 Wafer Plate Inline Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow range.
More informationAutomotive Flow Measurement and Control Products
Automotive Flow Measurement and Control Products Control. Manage. Optimize. Automotive Flow Measurement and Control Products When every drop counts, choose automotive flow measurement and control products
More informationProduct Data Sheet. Recordall Disc Meters. Lead-Free Bronze Alloy, Sizes 5/8, 5/8 x 3/4, 3/4 & 1 inch NSF/ANSI Standards 61 and 372 Certified
Recordall Disc Meters LeadFree Bronze Alloy, Sizes /8, /8 x 3/4, 3/4 & inch NSF/ANSI Standards 6 and 372 Certified 2 /8 in., /8 3/4 in. 3 3/4 in. in. 7 in. DESCRIPTION The Recordall Disc Series meters
More informationProduct Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS
DESCRIPTION Turbine Flow Meter QuikSert The QuikSert in-line turbine flow meter was developed for liquid applications where accuracy and dependability are needed. QuikSert s stainless steel body incorporates
More informationProduct Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE
VN2000 Flow Meters Hot Tap Insertion Meter DESCRIPTION The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow
More informationTurbine Flow Meter. Model User Manual. TRB-UM EN-03 (December 2015)
Turbine Flow Meter Model 1200 TRB-UM-00290-EN-03 () User Manual Turbine Flow Meter, Model 1200 CONTENTS Scope of This Manual 3 Unpacking and Inspection 3 Safety 3 Terminology and Symbols 3 Considerations
More informationElectronic Preset Meter. Model EPM2-ADV-SF, Advanced Series, Special Fluids. User Manual. AUT-UM EN-05 (August 2015)
Electronic Preset Meter Model EPM2-ADV-SF, Advanced Series, Special Fluids AUT-UM-00916-EN-05 () User Manual Electronic Preset Meter, Model EPM2-ADV-SF, Advanced Series, Special Fluids Page ii AUT-UM-00916-EN-05
More informationUser Manual. Industrial Meters. Oscillating Piston, Sizes 1/2", 1" and 2" Model OP Sanitary (3A Approved) and Model OP Chemical
Industrial Meters Oscillating Piston, Sizes 1/2", 1" and 2" Model OP Sanitary (3A Approved) and Model OP Chemical OPM-DS-00291-EN-03 () User Manual Industrial Meters, Oscillating Piston, Sizes 1/2", 1"
More informationIndustrial Meters. Oscillating Piston, Model OP Chemical & Sanitary, Sizes 1/2", 1", 2" User Manual. OPM-UM EN-02 (August 2013)
Industrial Meters Oscillating Piston, Model OP Chemical & Sanitary, Sizes 1/2", 1", 2" OPM-UM-00291-EN-02 (August 2013) User Manual Industrial Meter, Oscillating Piston, Sizes 1/2" through 2" Model OP
More informationProduct Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE
VN2000 Flow Meters Hot Tap Insertion Meter DESCRIPTION The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow
More informationRecordall Combo Meter Lead-Free Bronze Alloy, Size 8" (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM EN-02 (October 2013) User Manual
Recordall Combo Meter Lead-Free Bronze Alloy, Size 8" (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM-00077-EN-02 (October 2013) User Manual Recordall Combo Meter, 8" Page ii October 2013 User
More informationFlow-Alert Flow Switch
Flow-Alert Flow Switch GPM LPM OIL FLOW-ALERT FLOW SWITCH 6000 PSI / 414 BARS MAX FORM #04-VAM-UM-00229 (September 2012) Installation & Operation Manual I - INTRODUCTION The Flow-Alert flow meter combines
More informationProduct Data Sheet. Positive Displacement Flow Meter B1750 DESCRIPTION
ESRIPTION Positive isplacement Flow Meter 175 The lancett Model 175 positive displacement flow meter provides high measurement accuracy, trouble-free operation and long service life for fluids over a wide
More informationPFM Portable Hydraulic Testers. PFM6, PFM6BD, and PFM8. Badger Meter. Installation & Operation Manual. 05-TUR-UM EN (September 2012)
PFM Portable Hydraulic Testers PFM6, PFM6BD, and PFM8 Badger Meter 5-TUR-UM-193-EN (September 12) Installation & Operation Manual Page ii September 12 CONTENTS INTRODUCTION 5 PFM6 Digital Hydraulic Tester
More informationProduct Data Sheet. Electronic Valve Actuator. SEVA (Smart Electronic Valve Actuator) DESCRIPTION FEATURES APPROVALS / RATINGS OPERATION
Electronic Valve ctuator SEV (Smart Electronic Valve ctuator) DESCRIPTION The SEV is our next generation Smart Electric Valve ctuator that provides our customers with an electric actuator with best-in-class
More informationTurbine Flow Meter. B16N Series FloClean Tri-Clover End Fitting. User Manual. TRB-UM EN-01 (December 2016)
Turbine Flow Meter B16N Series FloClean Tri-Clover End Fitting TRB-UM-02253-EN-01 () User Manual Turbine Flow Meter, B16N Series FloClean Tri-Clover End Fitting CONTENTS Scope of This Manual 3 Unpacking
More informationProduct Data Sheet. Turbine Flow Meter. B16D Series FloClean Sanitary DESCRIPTION INSTALLATION REPAIR KITS
DESCRIPTION Turbine Flow Meter The FloClean Sanitary turbine flow meter was developed for use in the food, beverage and pharmaceutical industries. The 36L stainless steel construction provides a durable
More informationPVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables
PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria
More informationWIRING DIAGRAMS FOR BRIDGE CONTROL PANELS
WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS Bridge W/D's Panel Part # Page No. Nema-4/12 1-Speed 444231-** 2 Nema-4/12 1-Speed with Soft-Start 444711-** 3 Nema-4/12 2-Speed 444232-** 4 Nema-4/12 2-Speed
More informationIndustrial Turbo Meters. Sizes 2 in. through 6 in. User Manual. TUR-UM EN-21 (October 2017)
Industrial Turbo Meters Sizes 2 in. through 6 in. TUR-UM-00530-EN-21 () User Manual Industrial Turbo Meters, Sizes 2 in. through 6 in. Page ii TUR-UM-00530-EN-21 User Manual CONTENTS Scope of the Manual
More informationLevel Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions
Level Alert Model 2000 Multi-Switch Liquid Level Sensor Assembly and Installation Instructions Kit Form Each unit is provided in kit form with step-by-step instructions, making it extremely easy to custom
More informationHR-20P Pneumatically Controlled Pressure Regulator
HR-20P Pneumatically Controlled Pressure Regulator Instruction and Service Manual Hydroplex Corporation 230 West Gloria Switch Rd. Lafayette, LA 70507 337-233-0626 www.hydroplexpumps.com I. General Instructions
More informationGC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY
GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for
More informationManufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1
STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com
More informationInstallation & Operation Manual. Impeller Flow Sensors. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.
Impeller Flow Sensors 250 and 228 Metal Tee IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. 872021-EN (August 2012) Rev. 8 Installation & Operation Manual 250 and 228
More informationTurbine Flow Meter B1500. User Manual. TRB-UM EN-02 (June 2016)
Turbine Flow Meter B1500 TRB-UM-01789-EN-02 () User Manual Turbine Flow Meter, B1500 Page ii TRB-UM-01789-EN-02 User Manual CONTENTS Safety information 5 Safety Symbol Explanations 5 Unpacking & Inspection
More informationU500w Ultrasonic Meter. Cold Water Meters. User Manual. ESM-UM EN-04 (September 2017)
U500w Ultrasonic Meter Cold Water Meters ESM-UM-02205-EN-04 () User Manual U500w Ultrasonic Meter CONTENTS About the U500w Ultrasonic Meter 3 Safety Information 3 Product Unpacking and Inspection 3 Meter
More informationVariable Area Flow Meters. Inline Pneumatic Flow Meter. User Manual. VAM-UM EN-02 (August 2014)
Variable Area Flow Meters Inline Pneumatic Flow Meter VAM-UM-00593-EN-02 () User Manual Variable Area Flow Meters, Inline Pneumatic Flow Meter CONTENTS Introduction.........................................................................
More informationOPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE
OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE GENERAL Units are intended to be used within 30 days after receipt. If they are to be stored for a longer period of time, contact the factory
More information80PK-2A Type K Immersion Probe
80PK-2A Type K Immersion Probe Instruction Sheet WARNING TO AVOID ELECTRICAL SHOCK, DO NOT USE THIS PROBE WHEN VOLTAGES EXCEEDING 24V AC RMS OR 60V DC ARE PRESENT. THE PROBE TIP IS ELECTRICALLY CONNECTED
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationEquipment Operation Manual. Loctite 250ml Bottle Hand Pump Part No Loctite 50ml Bottle Hand Pump Part No
Equipment Operation Manual Loctite 250ml Bottle Hand Pump Part No. 97001 Loctite 50ml Bottle Hand Pump Part No. 98414 Description The Loctite 250ml Bottle Hand Pump (item # 97001) is a hand-held bottle-top
More informationInstallation / Operation Instructions Sunnex ORION Series Exam Lights
Installation / Operation Instructions Sunnex ORION Series Exam Lights OR-120 OR-127 OR-220 OR-227 Models: OR-300 OR-400 OR-500 OR-600 1. APPLICATIONS The Sunnex ORION Series light was designed specifically
More informationINSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure
INSTALLATION/OWNER'S MANUAL DP1000 10" Woofer in Enclosure Installation Thank you for purchasing the DP1000 10" Woofer with enclosure. Although Dual has attempted to make sure all of the information contained
More informationSTAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications
STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform
More informationUSER MANUAL. Revision 1.0.1
9ABCDEF08 NMEA2000 EXHAUST MULTIFUNCTION GAS TEMPERATURE DISPLAY Part MODULE Numbers: & PROBE3345 USER Part Numbers: MANUAL 4510 USER MANUAL 1234567 Revision 1.0.1 Revision History 1 1 Introduction 3
More informationProduct Data Sheet. Flow Monitor. B2800 Series DESCRIPTION OPERATION FEATURES
Flow Monitor 2800 Series SRIPTION The 2800 flow monitor is designed to be comprehensive, user-friendly, flexible and cost efficient. This microprocessor-based display comes pre-calibrated when purchased
More information60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60
60 PSI Boost Gauge For Product Numbers: MT-DV01_60, MT-WDV01_60 Red: 12v Constant (un-switched) Source (+) Orange: 12v Dimmer (switched) Source (+) (optional) White: 12v Ignition (switched) Source (+)
More information7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide
7.3L POWERSTROKE BANJO BOLT KIT Fits 94-03 7.3L Powerstroke Diesel Installation Guide INSPECT CONTENTS OF THIS KIT THOROUGHLY BEFORE STARTING THE INSTALLATION PROCESS! IF YOU FIND A PROBLEM WITH YOUR PACKAGE:
More informationOPERATING INSTRUCTIONS AND PARTS LIST
OPERATING INSTRUCTIONS AND PARTS LIST SHAW-BOX HELICAL, HOLLOW SHAFT, TRAVERSE REDUCER GENERAL The reducer uses an adapter that goes between the reducer and the face mounted motor. For a triple reduction
More informationEWS FLUID END PARTS LIST
GARDNER DENVER Rev C September 2005 WELL SERVICING PUMP MODEL C-2500 QUINTUPLEX EWS FLUID END PARTS LIST ECN 1027623 C-2500 WELL SERVICING PUMP MAINTAIN PUMP RELIABILITY AND PERFORMANCE WITH GENUINE GARDNER
More informationOperating and Installation Instructions
Model Number 20902 Fabricator's Power Module Kit - Aluminum Operating and Installation Instructions CAUTION! This product is to be installed only by persons knowledgeable in the repair and modification
More informationBlinkerBeam Solar Controller
Blinker Division Solar LED Solutions The Route To Safety, One Solution At A Time BlinkerBeam Solar Controller BlinkerSign, BlinkerBeacon or RRFB 2.0 with 55 W Solar Panel User Guide TAPCO Traffic & Parking
More informationSPARTAN ERV WARRANTY LISTING. Chassis Frame Rails Lifetime of vehicle to original owner (includes crossmembers)
SPARTAN ERV WARRANTY LISTING Spartan ER Complete Vehicle Base Warranty Five (5) years Apparatus Body Ten (10) years Chassis Cab Ten (10) years Chassis Frame Rails Lifetime of vehicle to original owner
More informationTurbine Flow Meter. User Manual. Top Load 1 in. and 2 in. Meters. TRB-UM EN-01 (September 2018)
Turbine Flow Meter Top Load 1 in. and 2 in. Meters TRB-UM-02597-EN-01 () User Manual Turbine Flow Meter, Top Load 1 in. and 2 in. Meters CONTENTS Unpacking and Inspection.........................................
More informationWARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN
WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter
More informationINSTALLATION INSTRUCTION & OWNER S MANUAL
CS-2500 & CS-2500P Water Filtration System INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 1.2 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful
More informationInstallation Guide. Marine Filter SURT023M SURT024M
Installation Guide Marine SURT023M SURT024M suo0738a Product Description The APC by Schneider Electric Marine Application reduces the EMI (electro magnetic interference), produced by a connected that
More informationTERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)
TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for
More informationEQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number
EQUIPMENT Instructions Loctite Pneumatic 300 ml Cartridge Dispenser Part Number 1294304 1. Unpacking and Inspection Carefully unpack the Loctite Pneumatic 300 ml Cartridge Dispenser and examine the items
More informationS8JX-N/S8JX-G Series Replacement Brackets
Original model mounting method Bottom mounting Front mounting Side mounting Original model: S8JX-N/S8JX-G Replacement model: S8FS-G Replacement bracket Model scheduled to be discontinued Recommended replacement
More informationDUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual
Installation Instructions Tech Support: 856.768.8300 TechSupport@GlowShiftGauges.com DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual (1) Gauge (2) Controllers
More informationModel FM2642 Wall Mount. Full Motion Television Wall Mount
Model FM2642 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions FM2642 Television Wall Mount. For maximum benefit, please
More informationASSEMBLY OF TROLLEY TO HOIST
INSTRUCTIONS AND PARTS LIST RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS) GENERAL Yale Rigid Mount I-Beam Trolleys are designed especially for use on
More informationINVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA
FOR FREIGHTLINER CASCADIA Part #: P808 1004FC 08/05/2014 Doc 1.04 INST065 Page 1 Step 1: Unpack the plate assembly and both positive and negative cables. INSTALLATION INSTRUCTIONS Step 2: Insert the negative
More informationFranklin Fueling Systems
Submersible Pumping and Fuel Management Systems Limited Warranty - FE Petro and INCON Fueling Systems Limited Warranties. 90-Day Warranty Coverage (Applicable Only to Tank Gauge Software, OEM Equipment
More informationII DISTRIBUTION & SUBSTATION TYPE C
CapCheckIII DISTRIBUTION & SUBSTATION TYPE Ca p a c i t o r C h e c ke r Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e
More informationV200D VERIS Verabar (Double Rod) Installation and Maintenance Manual
V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual 173-EN Please read and save these instructions Contents General Safety Information...3 Product Information...3 Section 1: Scope...3
More informationDual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev
Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How
More informationSOLAR DASH CHARGING SYSTEM USER GUIDE
SOLAR DASH CHARGING SYSTEM Doc 1.01 INST049 INSTALLATION STEP 1 Place 20 watt solar panel in the dash of the vehicle facing up. Note: For ideal results position the vehicle in a manner in which the solar
More informationFREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC
FREQUENTLY ASKED QUESTION SERIES BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC Ihave been getting a bunch more comments and questions from customers
More informationEMISSION CONTROL WARRANTY STATEMENT
EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board, U.S. EPA and Zenith Power Products LLC (ZPP) are pleased to explain the emission control system
More informationV400D VERIS Verabar (Double Rod) Installation and Maintenance Manual
V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual 168-EN Please read and save these instructions Contents General Safety Information...3 Product Information...3 Section 1: Scope...3
More informationModel AS-FM64 Wall Mount. Full Motion Television Wall Mount
Model AS-FM64 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions AS-FM64 Television Wall Mount. For maximum benefit, please
More informationModel T2642 Wall Mount. Television Wall Mount with Tilt Option
Model T2642 Wall Mount Television Wall Mount with Tilt Option Getting Started Introduction Congratulations on the purchase of your new Audio Solutions T2642 Television Wall Mount. For maximum benefit,
More informationSHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)
SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS) GENERAL SHAW-BOX Rigid Mount I-Beam Trolleys are designed
More informationPCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems
O P E R A T I O N S Environmental Systems PCC Pump Cycle Counter M A N U A L PO Box 3726 Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America Only (734) 995-2547 Tele. (734) 995-1170 Fax info@qedenv.com
More informationMM10 Dual Cartridge Dispenser 1:1 & 2:1 A Style Cartridges MM10 Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridges
EQUIPMENT Operation Manual Loctite MM10 Dual Cartridge Dispensers 1633364 MM10 Dual Cartridge Dispenser 1:1 & 2:1 A Style Cartridges 1633365 MM10 Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridges 1633366
More informationml Dual Cartridge Dispenser 10:1 B Style Cartridge ml Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridge
EQUIPMENT Operation Manual Loctite 50ml Dual Cartridge Dispenser 1444133 50ml Dual Cartridge Dispenser 10:1 B Style Cartridge 1444134 50ml Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridge 1444135 50ml
More informationPLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.
PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.. (1) RG1000 EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY (1) 3-IN-1 USB CABLE (1) RG1000 EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY
More informationFrekote Adjustable Spray Applicator 6 Extension Extension Extension EQUIPMENT Operation Manual
Frekote Adjustable Spray Applicator 6 Extension 98183 12 Extension 98184 24 Extension 98185 EQUIPMENT Operation Manual 1 Please Observe The Following 1.1 Emphasized Sections Warning! Refers to safety regulations
More informationUser Manual. Recordall Compound Series Meter. Lead-Free Bronze Alloy, Sizes 2", 3", 4" & 6" NSF/ANSI Standards 61 and 372 Certified
Recordall Compound Series Meter Lead-Free Bronze Alloy, Sizes 2", 3", 4" & 6" NSF/ANSI Standards 61 and 372 Certified RCS-UM-00076-EN-04 (June 2016) User Manual Recordall Compound Series Meter, Lead-Free
More informationPMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks
- 1 - PMD DRIVER RELOCATION KIT For 1994-1999 Chevy 6.5L Diesel Trucks Part# 1036520 -- Installation Instructions -- PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. - 2 - Kit Contents BD P/N#
More informationGM Specification Annual Test Data
GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing
More informationV500 and V510 VERIS Verabar Installation and Maintenance Manual
V500 and V510 VERIS Verabar Installation and Maintenance Manual 167-EN Please read and save these instructions Contents General Safety Information...3 Product Information...3 Section 1: Scope...3 Purpose
More informationINSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA
www.dtimotors.com INSTRUCTION MANUAL Rotary Unidirectional Piezoelectric Motor Evaluation Kit (Model: UPM-28) Made in USA Rev. 6/2/2017 Table of Contents 1.0 Introduction... 2 2.0 Properties... 3 3.0 Unpacking
More informationMooney* Type 24/24S Restrictor
GE Oil & Gas Mooney* Type 24/24S Restrictor Installation, Operation and Maintenance Manual (Rev. C) GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC
More informationHeavy Duty Four Wheeled Walker
Heavy Duty Four Wheeled Walker Weight Capacity: 500 lbs. ITEM # W1802 Made in China 2011 ESSENTIAL MEDICAL SUPPLY, INC. Manufactured for Orlando, FL 32822 -- SAVE THESE INSTRUCTIONS -- Do not attempt to
More informationAdjustable Angled Incline Conveyor Owners Manual with Operating Instructions
Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions Revision 012211 Table of Contents Basic Conveyor Features 3 Getting Started 4 Setting Up the Incline Conveyor 5 Belt Removal
More informationDODGE CUMMINS GDP Twin CP-3 Big Line Kit
Installation Manual P/N 0306-TCP3 2003-07 DODGE CUMMINS GDP Twin CP-3 Big Line Kit Installation Instructions P/N 0306-TCP3 GDP Twin CP-3 Big Line Kit Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationLoctite Control Timer Part Number EQUIPMENT Operation Manual. Control Timer SEC. Technologies
I EQUIPMENT Operation Manual Warning: Electrical Hazard Disconnect Power Cord Before Removing Cover. Advertencia: Peligro eléctrico Desconecte el cable eléctrico antes de quitar la cubierta. 115 VAC, 50/60
More informationProduct Data Sheet. Turbine Flow Meters. Precision Series DESCRIPTION CALIBRATIONS APPLICATIONS
Turbine Flow Meters Precision Series DESRIPTION ox Precision Turbine Flow Meters have unprecedented mechanical linearity, resulting in minimizing, or negating, temperature induced viscosity influence.
More informationInstruction Sheet SRSR SERIES. Rotating Sliding Rail System
Instruction Sheet SRSR SERIES Rotating Sliding Rail System THANK YOU Thank you for purchasing the SRSR Series Rotating Sliding Rail System. Please read these instructions thoroughly before assembling this
More informationEASY CONNECT CRANE KIT Festoon Conductor Systems
ASSEMBLY INSTRUCTION MANUAL EASY CONNECT CRANE KIT Festoon Conductor Systems October, 2005 Copyright 2005, Yale Lift-Tech, division of Columbus McKinnon Corporation Part No. 117463-05 Mounting Instructions
More informationModel AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs
Model AS-RC3260 TV Cart Rolling Cart for Audio Mount System & Flat Panel TVs GETTING STARTED Introduction Congratulations on the purchase of your new Helios AS-RC3260 Rolling Cart. For maximum benefit,
More informationService Guide. E DRIVE Design Inc. Linear Actuators. Quality Since 1980
Service Guide E DRIVE Design Inc. Linear Actuators VecTac VT R DRIVE Quality Since 1980 Contents www.edriveactuators.com Important Information for Users 2 Installation Considerations 3 Air Purge and Vent
More information