RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

Size: px
Start display at page:

Download "RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled"

Transcription

1 RELIEF VALVES Remote ontrol / Direct ype ilot Operated / Solenoid ontrolled Up to 5 Ma (3630 SI), 0 L /m in (06 U.S.GM) ub. E-00 Remote ontrol Relief Valves... age 3 his valve is used as a remote control valve for pilot operated type pressure control valves. Direct ype Relief Valves age 6 his valve is used in a hydraulic circuit to prevent damage due to over pressure and to adjust the maximum circuit pressure of small capacity. ilot Operated Relief Valves... age 9 hese valves protect the hydraulic system from excessive pressure, and can be used to maintain constant pressure in a hydraulic system. Remote control and unloading are permitted by using vent circuits. Low Noise ype ilot Operated Relief Valves... age 6 ilot operated relief valves here have been particularly develop-ed as low-noise types. Able to protect pumps and control valves against excessive pressures, they are used to control the pressure in the hydraulic system to a constant level. Remote control and unloading are permitted by using vent circuits. Solenoid ontrolled Relief Valves... age 0 hese valves are a combination of a pilot operated relief valve and a solenoid operated directional valve. iping between the two is eliminated as the solenoid valve is directly mounted on the relief valve and connected with the relief valve vent. ump pressure may be unloaded remotely by an electrical signal to the solenoid, or by connecting pilot relief valves to the solenoid valve ports. a "A" "B" b Low Noise ype Solenoid ontrolled Relief Valves... age 3 he low-noise solenoid controlled relief valve is a combination of a low-noise type pilot operated relief valve and a solenoid operated directional valve. It is used for no-load pump operation by using electric signals or, together with a remote control relief valve, for two or three pressure control of the hydraulic system. a "A" "B" b No.

2 RELIEF VALVES Remote ontrol / Direct ype ilot Operated / Solenoid ontrolled Instructions / Hydraulic Fluids AUION When making replacement of seals or solenoid assemblies, please do it carefully after reading through the relevant instructions in the Operator's Manual. Instructions o adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressures or anti-clockwise for lower pressures. After adjustments, do not forget to tighten the lock nut. iping of the tank line should not be connected to any tank line of the other valves, but connected directly to the tank. Hydraulic Fluids Fluid ypes Any type of hydraulic fluids listed in the table below can be used. etroleum base oils Sy nthetic fluids Water containing fluids Use fluids equivalent to ISO VG 3 or VG 46. Use phosphate ester or poly ol ester fluid. When phosphate ester fluid is used, prefix "F-" to the model number because the special seals (fluororubber) are required to be used. Use water-gly col fluid. Note: For use with hy draulic fluids other than those listed above, please consult y our Yuken representatives in advance. Recommended Viscosity and Oil emperatures Viscosity ranging between 5-0 mm /s ( SSU). Oil temperatures between -5/+70 (5-58 F). Use hydraulic fluids which satisfy the recommended viscosity and oil temperatures given above. ontrol of ontamination Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead to breakdowns and shorten the life of the valves. lease maintain the degree of contamination within NAS 638-Grade. Use 5 µm or finer line filter. No.

3 Remote ontrol Relief Valves D / DG-0 hreaded onnections / Specifications / Model Number Designation / others Specifications hreaded onnection D-0- Mounting DG-0- Max. Operating res. Ma (SI) 5 (3630) Approx. Mass kg (lbs.) D type DG type.6 (3.5).4 (3.) Model Number Designation F- D Special Seals Series Number y pe of Mounting -0 Valve - Design Number Design Standards F: Special Seals for hosphate Ester ype Fluids (Om it if not required) D: Rem ote ontrol Relief Valves : hreaded onnection G: Mounting 0 None: Japanese Std. "JIS" 80: European Design Std. 90: N. American Design Std. None: Japanese Std. "JIS" and European Design Std. 90: N. American Design Std. Instructions is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). If the internal volume of the vent line is too large, chattering is likely to occur. Graphic Symbol Attachment Mounting bolts Valve Model Socket Head ap Screw Qty. Numbers Japanese Std. "JIS" and European Design Std. N. American Design Std. DG-0 M5 45 Lg. No.0-4UN -3/4 Lg. 4 Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread Approx. Mass kg (lbs.) DG-0 DGM-0-0 Rc /4 DGM /4 BS.F DGM /4 N 0.7 (.5) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. hread hread No.3

4 D-0-/80/90 Remote ontrol Relief Valves D / DG-0 Installation Drawings Lock Nut 4(.55) Hex. DIMENSIONS IN MILLIMERES (INHES) wo ollars 5 (.05) 6(.0) D-0- "A" hd. Rc /4 D-0-80 /4 BS.F (.97) D-0-90 /4 N Fully Extended 93 (7.60) 4.5 (5.57) Adjustment Handle IN. Dimensions of he anel Mounting Hole Max. 0(.39) 47 (.85) 6(.0) 45(.77) Dia. (.83) Dia. ort "A" hd. 74 (.9) ank ort "A" hd. Lock Nut 4(.94) Hex. DG-0-/90 : DGM-0-0/080/090 7 (.8) 9 (.75) 30 (.8) 5.5(.) Dia. hrough 9(.35) Dia. Spotface 4 laces 60 (.36) Lock Nut 4(.55) Hex. wo ollars (.97) 30 (.8) 7 (.06) 5 (.59) (.08) 0 (.39) 6.(.4) Dia. "A" hd. laces (From Rear) 7.5 (.30) 4 (.94) 5 (.05) 38 (.) 45(.77) Dia. 4 (.55) 3.5 (.53) ort ank ort (.97) 0 (.39) 5 (.05) 9 (.75) 38 (.) 65 (.56) 80 (3.5) Fully Extended 4.5 (5.6) 00 (3.94) Adjustment Handle IN. "B" hd. 0(.39) Deep 4 laces 47 (.85) 38 (.) 37 (.45) 6 (.0) 48.5 (.9) 7(.8) Dia. hrough (.43) ' bore 7(.8) Deep laces Mounting Surface (s Furnished) "A" hd. "B" hd. DGM-0-0 DGM Rc /4 /4 BS.F M5 DGM /4 N No. 0-4 UN No.4

5 Remote ontrol Relief Valves D / DG-0 Spare arts List D-0-/80/90 AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual List of Seals Item 3 4 Name of arts arts Numbers SO-NA- SO-NB-.4 Qty. Note: When ordering the seals, please specify the seal kit number from the table below List of Seal Kits D-0 DG-0 Seal Kit Numbers KS-D-0- KS-DG-0- DG-0-/ List of Seals Item Name of arts arts Numbers Qty. SO-NA-9 SO-NB-9 Note: When ordering the seals, please specify the seal kit number from the table below. 4 5 No.5

6 Direct ype Relief Valves D / DG-0 hreaded onnections / Specifications / Model Number Designation / others Specifications Max. Operat- res. Adj. Max. Flow Approx. Mass hreaded ing Range L/min kg (lbs.) onnections Mounting Ma (SI) Ma (SI) (U.S.GM) D type DG type 6 D-0- - DG-0- (30) Note) (4.).5 (3.3).5 (3.3) Note: Refer to the Model Num ber Designation. Model Number Designation F- Special Seals F: Special Seals for hosphate Ester ype Fluids (Om it if not required) D Series Number D: Direct ype Relief Valves y pe of Mounting : hreaded onnection G: Mounting -0 Valve 0 -B res. Adj. Range Ma (SI) B: -7 ( -00) : (-0) H: 7- (00-30) - Design Number Design Standards None: Japanese Std. "JIS" 80: European Design Std. 90: N. American Design Std. None: Japanese Std. "JIS" and European Design Std. 90: N. American Design Std. Refer to the Minimum Adjustment haracteristics. Graphic Symbol Attachment Mounting bolts Valve Model Numbers Socket Head ap Screw Japanese Std. "JIS" and European Design Std. N. American Design Std. DG-0 M5 45 Lg. No.0-4UN -3/4 Lg. 4 Qty. Valve Model Numbers DG-0 Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) DGM-0-0 Rc /4 DGM /4 BS.F DGM /4 N 0.7 (.5) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for remote control relief valves. For dimensions, see page 4. No.6

7 Direct ype Relief Valves D / DG-0 haracteristics / Installation Drawings Min. Adjustment Min. Adjustment SI Ma L/min U.S. GM Flow Rate Nominal Override haracteristics SI Ma 7.5 D-0-H DG-0-H D-0- DG D-0-B DG-0-B L/min U.S. GM Flow Rate Lock Nut 4(.55) Hex. 5 (.05) 6(.0) (.97) D-0- - D "A" hd. Rc /4 /4 BS.F /4 N ort "A" hd. Fully Extended 63 (6.4) (4.4) Adjustment Handle IN. Max. 0(.39) 47 (.85) 6(.0) 45(.77) Dia. (.83) Dia. 74 (.9) Lock Nut 4(.94) Hex. 5 (.05) 9(.75) 7 (.8) ank ort "A" hd. 5.5(.) Dia. hrough 9(.35) Dia. Spotface 4 laces 45(.77) Dia. Lock Nut 4(.55) Hex. ort (.97) 0 (.39) ank ort Fully Extended 63 (6.4) 00 (3.94) Adjustment Handle IN. 47 (.85) 38 (.) 6 (.0) 48.5 (.9).0 Hy draulic fluid: Viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 D-0- -/80/90 Dimensions of he anel Mounting Hole DG-0- -/90 DIMENSIONS IN MILLIMERES (INHES) Mounting Surface (s Furnished) Note: For dimensions of the valve mounting surface, see the dimensional drawing (.4) of the sub-plate used together. No.7

8 Direct ype Relief Valves D / DG-0 Spare arts List D-0- -/80/90 DG-0- -/90 AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual List of Seals Item Name of arts art Numbers Qty. Remarks 3 4 SO-NB-9 SO-NA- SO-NB-.4 Use only for DG-0 Note: When ordering the seals, please specify the seal kit number from the table below. List of Seal Kits D-0 DG-0 Seal Kit Numbers KS-D-0- KS-DG-0- No.8

9 ilot Operated Relief Valves B / BG- / 06 /0 hreaded onnections / Specifications / Model Number Designation Graphic Symbols Vent onnection Specifications hreaded onnection B-- -3 B B Mounting BG-- -3 BG BG Max. Operating Ma (SI) 5 (3630) res. Adj. Range Ma (SI) Note) -5 ( -3630) Max. Flow L/min (U.S.GM) 00 (6.4) 00 (5.8) 0 (06) Approx. Mass kg (lbs.) B ty pe BG ty pe 5.0 (.0) 5.0 (.0) 8.5 (8.7) 4.7 (0.4) 5.6 (.3) 8.7 (9.) Note: Refer to the Minimum adjustment characteristics on page 4. Yuken can offer flanged connection valves described below. For details, contact us. BF BF BF Max Operating res. Ma (SI) 5 (3630) (30) Max Flow L /m in (U.S.GM) 0 (06) 800 () 00 (37) Model Number Designation F- B Special Seals F: Special Seals for hosphate Ester ype Fluids (Om it if not required) Series Number B: ilot Operated Relief Valves y pe of Mounting : hreaded onnection G: Mounting - Valve V High Venting res. Feature V: For High Venting Feature (Om it if not required) Use high venting pressure ty pe to reduce the response time from unload to onload. -3 Design Number Design Standards None: Japanese Std. "JIS" 80: European Design Std. 90: N. American Design Std. None: Japanese Std. "JIS" and European Design Std. 90: N. American Design Std. No.9

10 ilot Operated Relief Valves B / BG- / 06 / 0 Attachment / / Instructions Attachment Mounting Bolts Valve Socket Head ap Screw Japanese Std. "JIS" and European Design Std. N. American Design Std. BG- BG-06 BG-0 M 70 Lg. ( pcs.), M 95 Lg. ( pcs.) M6 60 Lg. ( pcs.), M6 80 Lg. ( pcs.) M0 70 Lg. ( pcs.), M0 90 Lg. ( pcs.) /-3UN -3/4 Lg. ( pcs.), /-3UN 3-3/4 Lg. ( pcs.) 5/8-UN -/4 Lg. ( pcs.), 5/8-UN 3-/4 Lg. ( pcs.) 3/4-0UN -3/4 Lg. ( pcs.), 3/4-0UN 3-/ Lg. ( pcs.) Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) BG- BGM--0 BGM-X-0 Rc 3/8 Rc / BGM BGM-X /8 BS.F / BS.F BGM--090 BGM-X-090 3/8 N / N.4 (5.3) 3. (6.8) BG-06 BGM-06-0 BGM-06X-0 Rc 3/4 Rc BGM BGM-06X /4 BS.F BS.F BGM BGM-06X-090 3/4 N N 4.7 (0.4) 5.7 (.6) BG-0 BGM-0-0 BGM-0X-0 Rc -/4 Rc -/ BGM BGM-0X /4 BS.F -/ BS.F BGM BGM-0X-090 -/4 N -/ N 8.4 (8.5) 0.3(.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good ma-chined finish. Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 8 L/min (. U.S. GM) and model 0 with 5 L/min (4.0 U.S. GM). here are two threaded connection pressure ports. hey can be connected each other in-line; one as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports. No.0

11 ilot Operated Relief Valves hreaded onnections:b- / 06 / 0 Installation Drawings B-- -3/380/390 B /380/390 B-0- -3/380/390 Lock Nut 4(.55) Hex. DIMENSIONS IN MILLIMERES (INHES) wo ollars "A" SQ. 4 positions of pressure adjustment handle are available by rotating cover assembly as shown. Vent ort "" hd. 380 Design Only 5 (.0) B Fully Extended Adjustment Handle IN. D F 45(.77) Dia. L J H K ort "S " hd. laces ank ort "S " hd. E Gauge onnection "U" hd. Q N A Dimensions mm (Inches) B D E F H J K L N Q B-- -3/380/390 B /380/390 B-0- -3/380/ (.95) 85 (3.35) (.57) (.97) 05 (4.3) 0 (3.98) 5 (.05) 80 (3.5) 78 (3.07) 96 (3.78).5 (5.93) 83 (7.0) 68.5 (.70) 89 (3.) 6 (.44) 74 (.9) 36 (.4) 49 (.93) 5 (.05) 80 (3.5) 90 (3.54) 0 (4.7) 45 (.77) 60 (.36) B-- B-- -3 B B B B B B B hread "S" hd. "" hd. "U" hd. Rc 3/8 Rc 3/8 Rc /4 3/8 BS.F 3/8 N Rc 3/4 3/4 BS.F 3/4 N Rc -/4 -/4 BS.F -/4 N 3/8 BS.F 3/8 N Rc 3/8 3/8 BS.F 3/8 N Rc 3/8 3/8 BS.F 3/8 N /4 BS.r /4 N Rc /4 /4 BS.r /4 N Rc /4 /4 BS.r /4 N No.

12 ilot Operated Relief Valves Mounting:BG- / 06 / 0 Installation Drawings BG-- -3/390 BG /390 BG-0- -3/390 MENSIONS IN MILLIMERES (INHES) Mounting Surface (s Furnished) Lock Nut 4(.55) Hex. wo ollars "A" SQ. 3 positions of pressure adjustment handle are available by rotating cover assembly as shown. B Fully Extended Adjustment Handle IN. Vent ort Locating in 6(.4) Dia. 45(.77) Dia. Gauge onnection "X " hd. Q 6 (.4) In case of BG-, no spotface are made at those two holes. N H U D V E F ort ank ort L K J "S " Dia. hrough "" Dia. Spotface 4 laces BG-- -3/390 BG /390 BG-0- -3/ (.95) 75 (.95) 85 (3.35) (.57) (.57) 45 (.77) 05 (4.3) 05 (4.3) 0 (3.98) 57 (.4) (.57) 47 (.85) 78 (3.07) 60 (.36) 67 (.64) 78 (3.07) 78 (3.07) 84 (3.3) 37 (5.39) 6 (6.34) 95 (7.68) Dimensions mm (Inches) A B D E F H J K L N Q S U V 4. (.56) 7 (.67) 0.7 (.8) 4 (.6) 5 (.05) 6 (.44) 8 (3.3) 04 (4.09) 4 (4.88) 7 (4.6) 4 (5.55) 75 (6.89) 77 (3.) 83.5 (3.9) 0 (4.33) (.87) 4.5 (.8) 6 (.4) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) 55 (.7) 38 (.) 45 (.77) 58 (.8) 65 (.56) BG-- -3 BG BG BG BG BG hread "X" hd Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N Mounting Surface ISO 664-AR-06--A ISO 664-AS-08--A ISO 664-A-0--A No.

13 for ilot Operated Relief Valves Installation Drawings BGM-,X-0 / 3080 / 090 BGM-06,06X-0 / 3080 / 090 BGM-0,0X-0 / 3080 / 090 "d" Dia. hrough "e" Dia. Spotface 4 laces "h" 4 laces J A B D F E "t" hd. 6.(.4) Dia. DIMENSIONS IN MILLIMERES (INHES) Z a H K X U S Q L Y V N 7(.8) Dia. 0(.39) Deep "n" hd. laces "b" Dia. laces f BGM- BGM-X BGM-06 BGM-06X BGM-0 BGM-0X BGM- BGM-X BGM-06 BGM-06X BGM-0 BGM-0X Dimensions mm (Inches) A B D E F H J K L N Q S (3.39) 3 6 (.0) (3.39) (.36) (.5) (.) (.) (.06) (5.87) (.5) (4.84) 95 (.6) (3.8) (.) (3.74) (.83) 08 (4.5) 6 (4.96) 78 (3.07) 94 (3.70) 5 (.59) 6 (.63) 70 (.76) 8.6 (3.5) 4 (.6) 5.7 (.) 35 (.38) 4.3 (.63) 80 (7.09) 7 (8.94) Dimensions mm (Inches) 5 (.59) 6 (.63) (5.9) 95 (7.68) 06.5 (4.9) 9 (4.69) 38. (5.44) 58 (6.) U V X Y Z a b d e f 9 (.75) 37 (.46) 4 (.65) 47.4 (.87) 55.5 (.9) 76. (3.00) 0 (0) 3.8 (.94) 3.8 (.5) (.87) 33.4 (.3) 44.5 (.75) (.87) (.43).7 (.) 3 (.6) (.57) (.57) (.97) (.97) 63 (.48) 0 (.79) 5 (.98) 3 (.6) 4.5 (.57) 3 (.9) 8 (.0) (.43) 3.5 (.53) 7.5 (.69) 7.5 (.69) (.83) 6 (.0) 5 (.0) 6 (.44) 9 (.75) 4 (.94) 3 (.) 7. (.07) 8 (.7) 30. (.9) 7 (.67) (4.76) 54 (6.06) 66.7 (.63) 88.9 (3.) Model Numbers BGM- BGM-X BGM-06 BGM-06X BGM-0 BGM-0X Japanese Standard "JIS" Design "0" European Design Standard Design "3080" N. American Design Standard Design "090" "h" "n" hd. "t" hd. "h" "n" hd. "t" hd. "h" "n" hd. "t" hd. Rc 3/8 Rc / M hd. 0(.79) Deep 3/8 BS.F / BS.F /-3UN hd. (.87) Deep 3/8 N / N Rc 3/4 3/4 BS. F 3/4 N Rc /4 M6 hd. /4 BS.F 5/8-UN hd. Rc 5(.98) Deep BS.F 7(.06) Deep N /4 N Rc-/4 Rc -/ M0 hd. 8(.0) Deep -/4 BS.F -/ BS.F 3/4-0UN hd. 8(.0) Deep -/4 N -/ N M hd. 0(.79) Deep M6 hd. 5(.98) Deep M0 hd. 8(.0) Deep No.3

14 ilot Operated Relief Valves B / BG- / 06 / 0 erformance haracteristics Nominal Override haracteristics B-, BG- SI SI Ma B-0, BG-0 Ma L/min U.S. GM Flow Rate L/min Hy draulic fluid:viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 B-06, BG-06 SI Ma L/min U.S. GM Flow Rate U.S. GM Flow Rate Min. Adj. & Vent vs. Flow SI Ma B-, BG- High Venting ype Vent Min. Adjustment Low Venting ype L/min U.S. GM Flow Rate Hy draulic fluid:viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 B-06, BG-06 SI Ma High Venting ype Vent Min. Adjustment Low Venting ype L/min U.S. GM Flow Rate B-0, BG-0 SI Ma High Venting ype Vent Min. Adjustment Low Venting ype L/min U.S. GM Flow Rate No.4

15 ilot Operated Relief Valves B / BG- / 06 / 0 Spare arts List B-- -3/380/390 B /380/390 B-0- -3/380/390 A AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual Item List of Seals Name of arts Bonded Seal art Numbers B- B-06 B-0 SO-NA-9 SO-NB-3 SG-FB-3/8 SO-NA-9 SO-NB-3 SG-FB-3/8 SO-NA-9 SO-NB-4 SG-FB-3/8 Qty. Note: When ordering the seals, please specify the seal kit number from the table below. BG-- -3/390 BG /390 BG-0- -3/ Section "A" for Design 380 List of Seal Kits B- B-06 B-0 Seal Kit Numbers KS-B--3 KS-B-0-3 Note: No bonded seals are included in the seal kits List of Seals Item Name of arts art Numbers Qty. BG- BG-06 BG-0 SO-NA-9 SO-NA-9 SO-NB-9 SO-NB- SO-NB-8 SO-NB-8 SO-NB-3 SO-NB-3 SO-NA-9 SO-NB-9 SO-NB-3 SO-NB-4 Note: When ordering the seals, please specify the seal kit number from the table below. List of Seal Kits Seal Kit Numbers BG- KS-BG--3 BG-06 KS-BG-06-3 BG-0 KS-BG-0-3 No.5

16 Low Noise ype ilot Operated Relief Valves S-BG- / 06 / 0 Specifications / Model Number Designation / Sub- Graphic Symbols Vent onnection Specifications Max. Operating Ma (SI) res. Adj. Range Ma (SI) Max. Flow L/min (U.S.GM) S-BG S-BG (3630) Note) (6.4) 00 (5.8) S-BG-0- - ( -3630) 0 (06) Note: See minimum adjustment pressure characteristics on page 8. Approx. Mass kg (lbs.) 4. (9.0) 5.0 (.0) 0.5 (3.) Model Number Designation F- S- B Special Seals Low Noise ype Series Number G y pe of Mounting - Valve -V -L High Venting res. Feature Direction of Handle - Design Number Design Std. F: Special Seals for hosphate Ester y pe Fluids (Om it if not required) S: Low Noise ype B: ilot Operated Relief Valves G: Mounting 06 0 V: For High Venting Feature (Om it if not required) Viewed from pressure gauge connection L: Left (Normal) R: Right Refer to. Use the high venting pressure ty pe where it is necessary to reduce the response time from unloading to onloading.. Design Standards: None... Japanese Standard "JIS" and European Design Standard N. American Design Standard Valve Model Numbers S-BG- S-BG-06 S-BG-0 Japanese Standard "JIS" European Design Standard N. American Design Standard BGM--0 BGM-X-0 BGM-06-0 BGM-06X-0 BGM-0-0 BGM-0X-0 hread Rc 3/8 Rc / Rc 3/4 Rc Rc -/4 Rc -/ BGM BGM-X-3080 BGM BGM-06X-3080 BGM BGM-0X-3080 hread 3/8 BS.F / BS.F 3/4 BS.F BS.F -/4 BS.F -/ BS.F BGM--090 BGM-X-090 BGM BGM-06X-090 BGM BGM-0X-090 hread 3/8 N / N 3/4 N N -/4 N -/ N Approx. Mass kg (lbs.).4 (5.3) 3. (6.8) 4.7 (0.4) 5.7 (.6) 8.4 (8.5) 0.3 (.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for pilot operated relief valves. For dimensions, see page 3. No.6

17 Attachment Mounting Bolts Valve Model Num bers S-BG- S-BG-06 S-BG-0 Low Noise ype ilot Operated Relief Valves Attachment / Instructions / Installation Drawings Japanese Std. "JIS" and European Design Std. M Lg. M6 Lg. M0 60 Lg. Socket Head ap Screw N. American Design Std. /-3 UN -/ Lg. 5/8- UN Lg. 3/4-0 UN -/4 Lg. Qty Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 5 L/min (.3 U.S. GM) and model 0 with 8 L/min (. U.S. GM). S-BG-- -L-/90 S-BG-06- -L-/90 S-BG-0- -/90 DIMENSIONS IN MILLIMERES (INHES) Fully Extended J Fully Extended F E "K" Dia. hrough "N" Dia. Spotface 4 laces ort D B A Mounting surface S-BG-: ISO 664-AR-06--A S-BG-06: ISO 664-AS-08--A S-BG-0: ISO 664-A-0--A Opposite Handle osition S-BG R Z Fully Extended J Q Adjustment Handle IN. 45(.77) Dia. ank ort H wo ollars Lock Nut 4(.55) Dia. Vent ort Gauge onnection "Y " hd Note:For other dimensions, see the figures shown left. Note:For dimensions of the valve mounting surface, see the dimensional drawing (. 3) of the sub-plate used together. S "Y" hd. 6 (.4) Locating in 6(.4) Dia. Mounting Surface (s Furnished) V U X S-BG S-BG S-BG S-BG S-BG-0- - S-BG Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N Rc /4 = /4 BS.r /4 N S-BG- S-BG-06 S-BG-0 A 76 (.99) 98 (3.86) 0 (4.7) Dimensions mm (Inches) B D E F H J K N Q S U V X Z 53.8 (.) 70 (.76) 8.6 (3.5). (.44) 4 (.55) 8.7 (.74) 6.9 (.06) 35 (.38) 4.3 (.63) 53.8 (.) 66.7 (.63) 88.9 (3.) 73.6 (.90) 58.8 (.3).6 (.99) 6.9 (.06) 33.7 (.33) 44.9 (.77) 63.5 (6.44) 63.5 (6.44) 80 (7.09) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) (.97) (.97) 65 (.56) 30 (5.) 30 (5.) 67 (6.57) (4.06) (4.06) 35 (5.3).5 (.85) 6 (.0) 33.5 (.3) 06 (4.7) (4.80) 55 (6.0) 6. (.) 9.3 (.76). (.83) 3 (.5) 3 (.5) 8 (.7) 36. (.4).3 (.84) No.7

18 Low Noise ype ilot Operated Relief Valves erformance haracteristics SI Ma Nominal Override haracteristics Hy draulic fluid: Viscosity : 35 mm /s (64 SSU) S-BG- S-BG-06 Specific Gravity : 0.8 S-BG U.S. GM Flow Rate SI Ma L/min L/min U.S. GM Flow Rate SI Ma L/min Flow Rate U.S. GM Min. Adj. and Vent vs. Flow Hy draulic fluid: Vent Min. Adjustment Viscosity : 35 mm /s (64 SSU) Specific Gravity : 0.8 S-BG- S-BG-06 S-BG-0 SI Ma 0.9 High Vent 0.8 ype Low Vent 0.3 ype L/min Flow Rate 5 U.S. GM SI Ma High Vent ype Low Vent 0 ype 0 00 L/min Flow Rate U.S. GM SI Ma High Vent ype Low Vent ype L/min Flow Rate U.S. GM Noise Level M easuring condition Viscosity : 35 mm /s (64 SSU) Measuring position: At m (3.3 ft.) back from the valve front. Back pressure : 0. Ma (4.5 SI) S-BG- S-BG-06 S-BG-0 db(a) 80 Flow rate : L/min (3. U.S.GM) db(a) 80 Flow rate : L/min (39.6 U.S.GM) db(a) 80 Flow rate : 00 L/min (5.8 U.S.GM) Noise Level Noise Level Noise Level Ma Ma Ma SI SI SI No.8

19 Low Noise ype ilot Operated Relief Valves Spare arts List S-BG-,06,0- -/ AUION When making replacement of seals, please do it carefully after reading through the relevant instructions in the Operator's Manual. S-BG List of Seals Item Name of arts art Numbers S-BG- S-BG-06 S-BG-0 5 SO-NB-9 SO-NB-9 SO-NB-9 6 SO-NA-9 SO-NA-9 SO-NA-9 7 SO-NB-9 SO-NB- SO-NB-9 8 SO-NB-8 SO-NB-8 SO-NB-3 9 SO-NB-A04 SO-NB-A04 SO-NB-A8 30 SO-NB-8 SO-NB-8 SO-NB-36 3 SO-NB-3 SO-NB-3 SO-NB-4 3 SO-NB-4 Note: When ordering the seals, please specify the seal kit number from the table below. Qty. List of Seal Kits Seal Kit Numbers S-BG- KS-S-BG-- S-BG-06 KS-S-BG-06- S-BG-0 KS-S-BG-0- Interchangeability in Installation betw een onventional ype and Low -noise ype he design of low-noise S-BG-, -06, and -0 is interchangeable for installation with design 3 of conventional BG-, -06 and -0. heir exterior shapes such as the position of the pressure adjustment handles are different. U V W onventional ype: BG Fully Extended 45 (5.7) 45(.77) Dia. Adjustment Handle Vent ort Gauge onnection ort ank ort, Design B A E "K" Dia. hrough "N" Dia. Spotface 4 laces ort Fully Extended J E Fully Extended F A B DIMENSIONS IN MILLIMERES (INHES) Low-noise type: S-BG- 06, Design 0 Vent ort Gauge onnection "K" Dia. hrough "N" Dia. Spotface 4 laces ank ort 45 (.77) Dia. W Adjustment Handle A B E K N U V A B E F K N J W BG- BG-06 BG-0 8 (3.3) 04 (4.09) 4 (4.88) 53.8 (.) 70 (.76) 8.6 (3.5) 53.8 (.) 66.7 (.63) 88.9 (3.) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) 7 (4.6) 4 (5.55) 75 (6.89) 55 (.6) 38 (.) 45 (.77) 78 (3.07) 58 (.8) 65 (.56) S-BG- S-BG-06 S-BG-0 76 (.99) 98 (3.86) 0 (4.7) 53.8 (.) 70 (.76) 8.6 (3.5) 53.8 (.) 66.7 (.63) 88.9 (3.) 73.6 (.90) 58.8 (.3).6 (.99) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 6 (.0) 3 (.6) 63.5 (6.44) 63.5 (6.44) 80 (7.09) 0.5 (.8) 5 (.98) 3.5 (.8) No.9

20 Specifications Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 hreaded onnections / Specifications / Model Number Designation hreaded onnection Mounting BS BS BSG BSG Max. Operating Adj. Range Max. Flow L/min Ma (SI) Ma (SI) (U.S.GM) 5 (3630) 5 (3630) Note) -5 ( -3630) Note) -5 ( -3630) 00 (6.4) 00 (5.8) 0 (06) 00 (6.4) 00 (5.8) 0 (06) Double Sol. 7.4 (6.3) 7.4 (6.3). (4.5) 7. (5.7) 8.0 (7.6).3 (4.9) Approx. Mass kg (lbs.) Single Sol. 6.8 (5.0) 6.8 (5.0) 0.5 (3.) 6.5 (4.3) 7.4 (6.3) 0.7 (3.6) W ith Vent Restrictor 7.8 (7.) 7.8 (7.).5 (5.4) 7.5 (6.5) 8.4 (8.5).7 (5.8) Note: For relief valves, standard pilot operated relief valves are used. For minimum adjustment pressures and other characteristics, see page 4. Solenoid Ratings Electric Source A D (K Series) A D Rectified oil Frequency ype (Hz) A00 A0 A00 A D D4 D48 R00 R /60 Voltage (V) Source Rating Serviceable Range 80~0 90~0 96 ~3 08 ~44 60~0 80~ 9 ~64 6 ~ ~3..6 ~ ~ ~0 80~0 urrent & ower at Rated Voltage Inrush (A) Holding (A) Inrush current in the above table shows rms values at maximum stroke. he coil type numbers in the shaded column are handled as optional extras. In case these coils are required to be chosen, please confirm the time of delivery with us before ordering. ower (W) 9 9 Yuken can offer flanged connection valves described below. onsult Yuken for the details. BSF BSF Max. Operating Ma (SI) 5 (3630) Max. Flow L/min (U.S.GM) 0 (06) 800 () Model Number Designation F- Special Seals A- W ith Vent Restrictor BS - -V -B3A -A00 -N -47 Series Number y pe of Mounting Valve High Venting res. Feature Vent ype oil y pe y pe of Electrical on. Design Number Design Standards F: Special Seals for hosphate Ester ype Fluids (Om it if not required) A: W ith Vent Restrictor (Option) BS: Solenoid ontrolled Relief Valves : hreaded onnection G: Mounting 06 0 V: For High Venting Feature (Om it if not required) B3A B3B BB B A: A00, A0 A00, A D: D, D4 D48 A D: R00, R00 None: erminal Box y pe N: W ith lug-in onnector (DIN) N: W ith lug-in onnector (DIN) 47 None: Japanese Std. "JIS" 90: N. American Design Std. 80: European Design Std.. Models with vent restrictor are applicable only for the vent ty pe B3A and B3B. For details, see page.. 3. Use high-venting-pressure ty pes to reduce response time from unloading to onloading. For the details of the vent ty pes, see the following page. No.0

21 Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 Vent ypes / Attachment Vent ypes Vent y pe Graphic Sy mbols Solenoid Operated Directional Valve Model Number SOL "a" Operation SOL "b" Vent onnecting B3A "A" b DSG-0-B3A OFF onnected to port "A". ON onnected to tank (no-load) "B" b OFF onnected to tank (no-load) B3B DSG-0-B3B ON onnected to port "B". "B" b OFF losed state (relief valve setting pressure) BB DSG-0-BB ON onnected to port "B". "A" "B" b OFF onnected to port "A". B DSG-0-B ON onnected to port "B". a "A" "B" b OFF OFF losed state (relief valve setting pressure) 3 DSG-0-3 ON OFF onnected to port "A". OFF ON onnected to port "B". a "A" "B" b OFF OFF onnected to tank (no-load) 33 DSG-0-33 ON OFF onnected to port "A". OFF ON onnected to port "B". Attachment Mounting Bolts Valve Model Socket Head ap Screw Numbers Japanese Std. "JIS" and European Design Std. N. American Design Std. BSG- BSG-06 BSG-0 M 70 Lg. ( pcs.), M 95 Lg. ( pcs.) M6 60 Lg. ( pcs.), M6 80 Lg. ( pcs.) M0 70 Lg. ( pcs.), M0 90 Lg. ( pcs.) /-3UN -3/4 Lg. ( pcs.), /-3UN 3-3/4 Lg. ( pcs.) 5/8-UN -/4 Lg. ( pcs.), 5/8-UN 3-/4 Lg. ( pcs.) 3/4-0UN -3/4 Lg. ( pcs.), 3/4-0UN 3-/ Lg. ( pcs.) No.

22 Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 / Option / Instructions Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) BSG- BSG-06 BSG-0 BGM--0 BGM-X-0 BGM-06-0 BGM-06X-0 BGM-0-0 BGM-0X-0 Rc 3/8 Rc / Rc 3/4 Rc Rc -/4 Rc -/ BGM BGM-X-3080 BGM BGM-06X-3080 BGM BGM-0X /8 BS.F / BS.F 3/4 BS.F BS.F -/4 BS.F -/ BS.F BGM--090 BGM-X-090 BGM BGM-06X-090 BGM BGM-0X-090 3/8 N / N 3/4 N N -/4 N -/ N.4 (5.3) 3. (6.8) 4.7 (0.4) 5.7 (.6) 8.4 (8.5) 0.3(.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for pilot operated relief valves. For dimensions, see page 3. Option Models with vent restrictor he type with a vent restrictor has a vent restrictor in vent types B3A and B3B added between a relief valve and a solenoid operated directional valve. If prevents shock to the main circuit by gradually lowering the venting pressure in the shift from the set pressure to unloading. Unloading pressure are the same as without a vent restrictor. A-BS - -B3A A-BS - -B3B b b Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 8 L/min (. U.S. GM) and model 0 with 5 L/min (4.0 U.S. GM). here are two threaded connection pressure ports. hey can be connected each other in-line; one as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports. Interchangeability in Installation betw een Old and New Design. Design 47 valve is one on which DSG-0,design 60 is mounted as a pilot valve. It is interchangeable with old design (design 46) with respect to specifications, exterior shape and mounting dimensions. No.

23 Solenoid ontrolled Relief Valves hreaded onnections:bs- / 06 / 0 Installation Drawings BS-- -47/4790 BS /4790 BS /4790 erminal Box ype Solenoid Indicator Light DIMENSIONS IN MILLIMERES (INHES) "" SQ. Vent ort "k" hd. ank ort "X " hd. D 48 (.89) "E " Sq. F Fully Extended H osition can be shifted by 90 Steps. Lock Nut 4(.55) Hex. 45(.77) Dia. wo ollars Adjustment Handle IN. Remote ontrol ort "B" "W " hd. ort "X " hd. laces Gauge onnection "h" hd. 0.5 (.0) D/R :0(8.7) A :9.4(7.54) SOLa 45 D/R :05(4.3) (.77) A :95.7(3.77) 45(.77) K L SOLb V Space Needed to Remove Solenoid-Each End D/R :55(.7) A :45.5(.79) U S Electrical onduit onnection "r" hd. laces Q N Remote ontrol ort "A" "W " hd. Manual Actuator Both Ends 6(.4) Dia. D E Dimensions mm (Inches) F H K L N Q S U V BS-- -47/4790 BS / (.95) (.57) 5 (.05) 78 (3.07) 45 (5.7) 45 (.77) 90 (3.54).8 (9.48) 68.5 (.70) 54 (6.06) 36 (.4) 07 (4.) 69 (.7) 6 (.44) BS / (3.35) (.97) 80 (3.5) 96 (3.78) 5 (5.94) 60 (.36) 0 (4.7) 73.3 (0.76) 89 (3.) 66 (6.54) 49 (.93) 9 (4.69) 8 (3.9) 74 (.9) BS- BS-06 BS-0 Japanese Standard "JIS" Design 47 N. American Design Standard Design 4790 "W " hd. "X" hd. "h" hd. "k" hd. "r" hd. "W " hd. "X" hd. "h" hd. "k" hd. "r" hd. Rc 3/8 3/8 N Rc /8 Rc 3/4 Rc -/4 Rc /4 Rc 3/8 G / /8 /4 3/8 / 3/4 N N N N N -/4 N No.3

24 Models with lug-in onnector BS N-47/4780/ ort "X " hd. laces SOL a Remote ontrol ort "B" "W " hd. Vent ort "m" hd. (Rear Side) D/R A 48.5 (.9) :0(8.7) :9.4(7.54) 48.5 (.9) ank ort "X " hd. h Solenoid ontrolled Relief Valves hreaded onnections:bs- / 06 / 0 Installation Drawings Design 4780 Only able Departure able Applicable: Outside Dia. 8-0mm( in.) onductor Area Not Exceeding.5mm (.00 SQ. in.) QQ NN Remote ontrol ort "A" "W " hd Gauge onnection "k" hd DIMENSIONS IN MILLIMERES (INHES) BS-- -A BS-06- -N -A -N BS-0- -A -N BS-- -D -N BS-06- -D -N BS-0- -D -N BS-- -R -N BS-06- -R -N BS-0- -R -N 68.5 (.70) 89 (3.) 68.5 (.70) 89 (3.) 68.5 (.70) 89 (3.) Dimensions mm(inches) NN QQ h 07 (4.) 9 (4.69) 07 (4.) 9 (4.69) 07 (4.) 9 (4.69).5 (9.47) 73 (0.75) 5.5 (9.90) 84 (.8) 54.5 (0.0) 87 (.30) 60 (6.30) 7 (6.77) 7 (6.73) 83 (7.0) 64. (6.46) 76. (6.94) 39 (.54) 39 (.54) 53 (.09) "W " hd. "X" hd. "k" hd. "m" hd. BS N-4780 BS N-4780 BS N-4780 /8 BS.F 3/8 BS.F 3/4 BS.F -/4 BS.F /4 BS.r 3/8 BS.r See the installation drawing of terminal box ty pe on page 3 for design 47 and 4790 port screws and other dimensions. Options - Models w ith Vent Restrictor erminal Box ype A-BS B3A B3B - -47/ D/R :05(4.3) A :95.7(3.77) lug-in onnector ype A-BS B3A B3B - -N-47/4780/ D/R :05(4.3) A :95.7(3.77) NN QQ N Q Item A-BS- A-BS-06 A-BS (.70) 89 (3.) 37 (5.39) 49 (5.87) lug-in onnector y pe erminal Box y pe A Solenoid D Solenoid R (A D) Solenoid N Q NN QQ NN QQ NN QQ 70.8 (0.66) 3.3 (.94) 84 (7.4) 96 (7.7) 70.5 (0.65) 3 (.93) 90 (7.48) 0 (7.95) 8.5 (.08) 34 (.36) 0 (7.9) 3 (8.39) 84.5 (.0) 37 (.48) 94. (7.65) 06. (8.) For other dimensions, see the models without vent restrictor ty pe on page 3 and 4. No.4

25 BSG-- -47/4790 BSG /4790 BSG /4790 erminal Box ype Solenoid ontrolled Relief Valves Mounting:BSG- / 06 / 0 Installation Drawings Solenoid Indicator Light Mounting surface BSG-: ISO 664-AR-06--A BSG-06: ISO 664-AS-08--A BSG-0: ISO 664-A-0--A DIMENSIONS IN MILLIMERES (INHES) "" SQ. Mounting Surface (s Furnished) Locating in 6(.4) Dia. 6 (.4) D 48 (.89) wo ollars 45(.77) Dia. Lock Nut 4(.55) Hex. Adjustment Handle IN. 0.5 (.0) SOLa Remote ontrol ort "B" "d" hd. Vent ort Gauge onnection "e" hd. D/R :0(8.7) A :9.4(7.54) 45 (.77) D/R :05(4.3) A :95.7(3.77) 45 (.77) SOLb X V Space Needed to Remove Solenoid-Each End U D/R :55(.7) A :45.5(.79) Electrical conduit connection "f" hd. laces S Q Manual Actuator Both Ends 6(.4) Dia. Remote control port "A" "d" hd. In case of BSG-, no spotface are made at those two holes. a E b F H Fully Extended J ort ank ort N L K "Y " Dia. hrough "Z" Dia. Spotface 4 laces Model Numbers BSG- BSG-06 BSG-0 D E F H J K L N Q S U V X Y Z a b 75 (.95) 75 (.95) 85 (3.35) (.57) (.4) (3.07) (3.07) (5.7) (.57) (.57) (.36) (3.07) (5.7) (.77) (.85) (.64) (3.3) (5.75) 4. (.56) 7 (.67) 0.7 (.8) 4 (.6) 5 (.05) 6 (.44) Dimensions mm (Inches) 8 (3.3) 04 (4.09) 4 (4.88) 7.3 (8.95) 5.3 (9.89) 77 (3.) 83.5 (3.9) (.3)(4.33) 3 (5.0) 49.5 (5.89) 57 (6.8) (.87) 4.5 (.8) 6 (.4) (3.35) (.85) (4.04) (.54) 0 7 (4.33) (.83) (.57) 57.5 (.6) 65 (.56) 3.5 (.53) 7.5 (.69).5 (.85) (.83) 55 (.7) 6 38 (.0) (.) 3 45 (.6) (.77) 58 (.8) 65 (.56) BSG- BSG-06 BSG-0 Japanese Standard "JIS" Design 47 N. American Design Standard Design 4790 "d" hd. "e" hd. "f" hd. "d" hd. "e" hd. "f" hd. Rc /8 Rc /4 G / /8 N /4 N / N Note: For dimensions of the valve mounting surface, see the installation drawing (.3) of the sub-plate used together. No.5

26 Solenoid ontrolled Relief Valves Mounting:BSG- / 06 / 0 Installation Drawings Models with lug-in onnector BSG N-47/4780/ Remote ontrol ort "B" "d" hd. Vent ort SOLa D/R :0(8.7) A :9.4(7.54) 48.5 (.9) 48.5 (.9) h SOLb Design 4780 Only able Departure able Applicable: Outside Dia. 8-0mm( in.) onductor Area Not Exceeding.5mm (.00 SQ. in.) U SS Q BSG-- -A -N BSG-06- -A -N BSG-0- -A -N BSG-- -D -N BSG-06- -D -N BSG-0- -D -N BSG-- -R -N BSG-06- -R -N BSG-0- -R -N 77 (3.) 83.5 (3.9) 0 (4.33) 77 (3.) 83.5 (3.9) 0 (4.33) 77 (3.) 83.5 (3.9) 0 (4.33) Dimensions mm(inches) Q U SS h 85 (3.35) 0.5 (4.04) 0 (4.33) 85 (3.35) 0.5 (4.04) 0 (4.33) 85 (3.35) 0.5 (4.04) 0 (4.33) 7 (8.94) 5 (9.88) 85 (.) 38 (9.37) 6 (0.3) 96 (.65) 4 (9.49) 65 (0.43) 99 (.77) 38 (5.43) 55.5 (6.) 63 (6.4) 49 (5.87) 66.5 (6.56) 74 (6.85) 4. (5.60) 59.7 (6.9) 67. (6.58) 39 (.54) 39 (.54) 53 (.09) ort ank ort DIMENSIONS IN MILLIMERES (INHES) D/R :05(4.3) A :95.7(3.77) Remote ontrol ort "A" "d" hd. Gauge onnection "e" hd Options - Models w ith Vent Restrictor erminal Box ype A-BSG B3A B3B - -47/ BSG N-4780 BSG N-4780 BSG N-4780 "d" hd. /8 BS.F "e" hd. /4 BS.r See the installation drawing of terminal box ty pe on page 5 for design 47 and 4790 port screws and other dimensions. lug-in onnector ype A-BSG B3A - -N-47/4780/4790 B3B 0 D/R :05(4.3) A :95.7(3.77) Q Q U U S SS Item A-BSG- A-BSG-06 A-BSG-0 Q 77 (3.) 83.5 (3.9) 0 (4.33) U 5 (4.53) 3.5 (5.) (5.5) lug-in onnector y pe erminal Box y pe A Solenoid D Solenoid R (A D) Solenoid S SS SS SS 57.3 (0.3) 8.3 (.07) 35.3 (.4) 6 (6.38) 79.5 (7.07) 87 (7.36) 57 (0.) 8 (.06) 35 (.) 68 (6.6) 85.5 (7.30) 93 (7.60) 68 (0.55) 9 (.) 36 (.83) 79 (7.05) 96.5 (7.74) 04 (8.) 7 (0.67) 95 (.6) 39 (.95) 7. (6.78) 89.7 (7.47) 97. (7.76) For other dimensions, see the models without vent restrictor ty pe on page 5 and 6.

27 Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 Lead Wire onnection Details of Receptacle y pe of Electrical onduit onnection Double Solenoid y pe Single Solenoid y pe ower Supply (For SOL.a) Ground 3 ower Supply (For SOL.b) 3 ower Supply 3 erminal Box y pe Indicator Light SOL. a SOL. b SOL. b ommon late Indicator Light Indicator Light ommon 3 Ground Ground lug-in onnector ype -ower Supply 3 3 Ground -ower Supply 3 3. here are two grounding terminals. You can use either one.. If y ou do not need the common plate, remove it. 3. With D solenoids, polarity is no question. DANGER Do not perform wiring while the power is on. Doing so may result in electric shock, burns or death. Make the wiring properly. Improper wiring will cause an irregular movement of the machine, resulting in a grave accident. Electrical ircuit y pe of Electrical onduit onnection Electric Source A D A D Rectified erminal Box y pe ower Supply Indicator Light ower Supply Indicator Light ower Supply Indicator Light Voltage-Surge Suppressor SOL. SOL. SOL. ommon Ground ommon Ground Voltage-Surge Suppressor ommon Ground Rectifier ircuit lug-in onnector ype -ower Supply -ower Supply Ground Indicator Light (Integrated in "N" model only) SOL. -ower Supply -ower Supply Ground Indicator Light (Integrated in "N" model only) SOL. Voltage-Surge Suppressor (ircuit composed in coil) -ower Supply -ower Supply Ground Voltage-Surge Suppressor Rectifier ircuit SOL. No.7

28 Solenoid ontrolled Relief Valves BS-,06,0 Spare arts List hreaded onnections erminal Box ype BS / AUION When making replacement of seals or solenoid assemblies, please do it carefully after reading through the relevant instructions in the Operator's Manual SOL a Models with lug-in onnector BS N-47/4780/ Option Models with Vent Restrictor 47/4790 A-BS N-47/4780/ SOL a Design 4780 Only List of Seals Item Name of arts Bonded Seal art Numbers BS- BS-06 BS-0 SO-NA-9 SO-NB-3 SG-FB-/8 SO-NA-9 SO-NB-3 SG-FB-/8 SO-NB-8 SO-NB-4 SO-NA-9 SO-NB-4 SG-FB-/8 Qty. he s for Item 38, are used only for the models with the vent restrictor. Note: When ordering the seals, please specify the seal kit number from the table right. In addition to the above seals, seals for the pilot valves are included in the seal kit. For the detail of the pilot valve seals, see the catalogue No. ub.e- 0. List of Seal Kits BS- BS-06 BS-0 A-BS- A-BS-06 A-BS-0 Seal Kit Numbers KS-BS--46 KS-BS-0-46 KS-A-BS--46 KS-A-BS-0-46 Note: No bonded seals are included in the seal kits. ilot Valves See page 30 for the pilot valve model numbers to be used. No.8

29 Mounting erminal Box ype BSG / Solenoid ontrolled Relief Valves BSG- / 06 / 0 Spare arts List AUION When making replacement of seals or solenoid assemblies, please do it carefully after reading through the relevant instructions in the Operator's Manual SOL a Models with lug-in onnector BSG N-47/4780/ Option Models with Vent Restrictor 47/4790 A-BSG N-47/4780/ SOL a 3 3 Design 4780 Only List of Seals Item Name of arts Bonded Seal art Numbers BSG- BSG-06 BSG-0 SO-NA-9 SO-NA-9 SO-NA-9 SO-NB-9 SO-NB- SO-NB-9 SO-NB-8 SO-NB-8 SO-NB-3 SO-NB-3 SO-NB-3 SO-NB-4 SG-FB-/8 SG-FB-/8 SG-FB-/8 SO-NB-8 SO-NB-4 Qty. he s for item 38, are used only for the models with the vent restrictor. List of Seal Kits BSG- BSG-06 BSG-0 A-BSG- A-BSG-06 A-BSG-0 Seal Kit Numbers KS-BSG--46 KS-BSG KS-BSG-0-46 KS-A-BSG--46 KS-A-BSG KS-A-BSG-0-46 Note:No bonded seals are included in the seal kits. ilot Valves See page 30 for the pilot valve model numbers to be used. Note: When ordering the seals, please specify the seal kit number from the table right. In addition to the above seals, seals for the pilot valves are included in the seal kit. For the detail of the pilot valve seals, see the catalogue No. ub. E- 0. No.9

30 Solenoid ontrolled Relief Valves BS / BSG- / 06 / 0 Spare arts List List of ilot Valves y pe of Electrical onduit onnection Valve Model Num bers -BS/BSG-/06/0- -B3A BS/BSG-/06/0- -B3B BS/BSG-/06/0- -BB BS/BSG-/06/0- -B BS/BSG-/06/ BS/BSG-/06/ BS/BSG-/06/0- -B3A BS/BSG-/06/0- -B3B BS/BSG-/06/0- -BB BS/BSG-/06/0- -B BS/BSG-/06/ BS/BSG-/06/ BS/BSG-/06/0- -B3A- -N-47 -BS/BSG-/06/0- -B3B- -N-47 -BS/BSG-/06/0- -BB- -N-47 -BS/BSG-/06/0- -B- -N-47 -BS/BSG-/06/ N-47 -BS/BSG-/06/ N-47 -BS/BSG-/06/0- -B3A- -BS/BSG-/06/0- -B3B- -BS/BSG-/06/0- -BB- -BS/BSG-/06/0- -B- -N BS/BSG-/06/ N BS/BSG-/06/ N BS/BSG-/06/0- -B3A- -BS/BSG-/06/0- -B3B- -BS/BSG-/06/0- -BB- -BS/BSG-/06/0- -B- -N BS/BSG-/06/ N BS/BSG-/06/ N-4790 ilot Valve DSG-0-B3A- -60 DSG-0-B3B- -60 DSG-0-BB- -60 DSG-0-B- -60 DSG DSG erminal Box y pe DSG-0-B3A DSG-0-B3B DSG-0-BB DSG-0-B DSG DSG DSG-0-B3A- -N-60 DSG-0-B3B- -N-60 DSG-0-BB- -N-60 DSG-0-B- -N-60 DSG N-60 DSG N-60 -N-4780 DSG-0-B3A- -N-60 -N-4780 DSG-0-B3B- -N-60 lug-in onnector y pe -N-4780 DSG-0-BB- -N-60 DSG-0-B- -N-60 DSG N-60 DSG N-60 -N-4790 DSG-0-B3A- -N N-4790 DSG-0-B3B- -N N-4790 DSG-0-BB- -N-6090 DSG-0-B- -N-6090 DSG N-6090 DSG N-6090 Note:. Fill a coil ty pe (a sy m bol representing current/voltage) in section m arked.. For the details of the pilot valves, see the atalogue No. ub. E-0. Rem arks Japanese Standard "JIS" N. American Design Std. Japanese Standard "JIS" European Design Std. N. American Design Std. No.30

31 Low Noise ype Solenoid ontrolled Relief Valves Specifications / Model Number Designation Specifications Mounting S-BSG S-BSG S-BSG Max. Operating Ma (SI) 5 (3630) Adj. Range Ma (SI) - 5 ( ) Max. Flow L/min (U.S.GM) 00 (6.4) 00 (5.8) 0 (06) Double Sol. 6.3 (3.9) 7. (5.9).7 (8.0) Approx. Mass Single Sol. 5.7 (.6) 6.6 (4.6). (6.7) kg (lbs.) W ith Vent Restrictor 6.7 (4.8) 7.6 (6.8) 3. (8.9) For relief valves, low-noise ty pe pilot operated relief valves are used. For minimum adjustment pressures and other characteristics, see page 8. Solenoid Ratings Solenoid ratings are the same as for the conventional type. See Solenoid Ratings on page 0. Model Number Designation F- A- S- BS G Special Seals W ith Vent Restrictor Low Noise ype Series Number ype of Mtg. - Valve size -V High Venting res. Feature -B3A Vent ype -A00 oil ype -N y pe of Electrical onnections -L Direction of Handle 5 Design Number Design Standards F: Special Seals for hosphate Ester ype Fluids (Om it if not required) A: W ith Vent Restrictor (option) S: Low Noise ype BS: Solenoid ontrolled Relief Valves G: Sub -plate Mtg V: For High Venting Feature (Om it if not required) 3 B3A B3B BB B 3 33 A: A00 A0 A00 A D: D D4 D48 A D: R00 R00 4 None: erminal Box y pe N: W ith lug-in onnector (DIN) N: W ith lug-in onnector (DIN) Viewed from pressure gauge onnection L: Left (Normal) R: Right 5 None: Japanese Std. "JIS" 90: N. American Design Std. 80: European Design Std.. Models with vent restrictor are applicable only for the vent ty pe B3A and B3B. For details, see page 3.. Use high-venting-pressure ty pes to reduce response time from unloading to onloading. 3. he vent ty pes are the same as for the conventional ty pe solenoid controlled relief valves. For the details of the vent ty pes, see page. 4. he coil codes are the same as for the conventional ty pe solenoid controlled valves. See the solenoid ratings on page 0. No.3

32 Low Noise ype Solenoid ontrolled Relief Valves Mounting : S-BSG- / 06 / 0 Option / / Attachment / Instructions Option Models with vent restrictor he type with a vent restrictor has a vent restrictor in vent types B3A and B3B added between a relief valve and a solenoid operated directional valve. It prevents shock to the main circuit by gradually lowering the venting pressure in the shift from the setting pressure to unloading. Unloading pressures are the same as without a vent restrictor. A-S-BSG- -B3A b A-S-BSG- -B3B b Valve Model Numbers Japanese Standard "JIS" European Design Standard N. American Design Standard hread hread hread Approx. Mass kg (lbs.) S-BSG- BGM--0 BGM-X-0 Rc 3/8 Rc / BGM BGM-X /8 BS.F / BS.F BGM--090 BGM-X-090 3/8 N / N.4 (5.3) 3. (6.8) S-BSG-06 BGM-06-0 BGM-06X-0 Rc 3/4 Rc BGM BGM-06X /4 BS.F BS.F BGM BGM-06X-090 3/4 N N 4.7 (0.4) 5.7 (.6) S-BSG-0 BGM-0-0 BGM-0X-0 Rc -/4 Rc -/ BGM BGM-0X /4 BS.F -/ BS.F BGM BGM-0X-090 -/4 N -/ N 8.4 (8.5) 0.3(.7) s are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. he sub-plates are those for pilot operated relief valves. For dimensions, see page 3. Attachment Mounting Bolts Valve Model Socket Head ap Screw Numbers Japanese Std. "JIS" and European Design Std. N. American Design Std. Qty. S-BSG- M Lg. /-3 UN -/ Lg. 4 S-BSG-06 M6 Lg. 5/8- UN Lg. 4 S-BSG-0 M0 60 Lg. 3/4-0 UN -/4 Lg. 4 Instructions If a remote control relief valve is used in the vent circuit, see page 3. In addition, if the internal volume of the vent line is too large, chattering is likely to occur. hus, as far as possible reduce the inside Dia. and the length of the pipe. is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 0 Ma (4 SI). With a small flow, the setting pressure may be unstable. Use models numbered and 06 with a flow rate above 5 L/min (.3 U.S. GM) and model 0 with 8 L/min (. U.S. GM). No.3

33 erminal Box ype Opposite Handle osition S-BSG R 06 SOL a B j A Low Noise ype Solenoid ontrolled Relief Valves Installation Drawings S-BSG L-5/ S-BSG /590 "N" Dia. hrough " " Dia. Spotface 4 laces Fully Extended J Fully Extended h H Mounting surface S-BSG-: ISO 664-AR-06--A S-BSG-06: ISO 664-AS-08--A S-BSG-0: ISO 664-A-0--A Solenoid Indicator Light ort E D F r m Note: For other dimensions, see the figures shown right Electrical onduit onnection Design Std. hd. 5 G / 590 / N laces 48 (.89) ank ort Space Needed to Remove Solenoid-Each End D/R :55(.7) A :45.5(.79) D/R :60(.36) A :.7(.00) L K D/R :0(8.7) A :9.4(7.54) (3.54) (.0) Vent ort Gauge onnection "nn" hd. Q S Remote ontrol ort "A" "ff" hd. U V Manual Actuator Both Ends 6(.4) Dia. Remote ontrol ort "B" "ff" hd. Adjustment Handle IN. 45(.77) Dia. wo ollars Lock Nut 4(.55) Hex. SOL a A B f X Mounting Surface Locating in Y (s Furnished) e 6(.4) Dia. Z d Model Dimensions mm (Inches) Numbers D E F H J K N Q S U V X Y Z d e f h m r S-BSG (.99)(.) (.44) (.06)(.)(.90)(.06) (.53) (.83) (8.59)(7.87)(6.0)(4.6)(4.06) (.85) (.67) (.44)(4.7)(.) (.5) (6.44)(5.0)(.4) S-BSG (3.86)(.76) (.55) (.38)(.63)(.3)(.33) (.69) (.0)(8.59)(7.87)(6.0)(4.6)(4.06)(.0)(.6)(.0)(4.80) (.76) (.5) (6.44)(5.60) (.84) S-BSG (4.7)(3.5) (.74) (.63)(3.)(.8)(.77) (.85) (.6)(9.97)(9.5)(7.)(5.87)(5.3)(.34)(.70)(.47)(6.0) (.83) (.7) (7.09) 6 (.4) Item S-BSG- S-BSG-06 S-BSG-0 L 68.8 (.7) 54 (.3) 4.8 (.65) A Solenoid j 58.7 (6.5) 58.7 (6.5) For the port screws, see the lug-in onnector ty pe on page 34. L 78. (3.07) 63.3 (.49) 5. (.0) D/R Solenoid j 68 (6.6) 68 (6.6) Note: For dimensions of the valve mounting surface, see the installation drawing (.3) of the subplate used together. DIMENSIONS IN MILLIMERES (INHES) No.33

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol. Specifications hreaded Connection Mounting BS-- - - - -47 BS-06- - - - -47 BS-0- - - - -47 BSG-- - - - -47 BSG-06- - - - -47 BSG-0- - - - -47 BS / BSG- / 06 / 0 hreaded Connections / Mounting Specifications

More information

Solenoid Controlled Relief Valves

Solenoid Controlled Relief Valves hese valves are a comination of a pilot operated relief valve and a solenoid operated directional valve. Piping etween the two is eliminated as the solenoid valve is directly mounted on the relief valve

More information

Low Noise Type Solenoid Controlled Relief Valves

Low Noise Type Solenoid Controlled Relief Valves he low-noise solenoid controlled relief valve is a combination of a low-noise type pilot operated relief valve and a solenoid operated directional valve. It is used for no-load pump operation by using

More information

Hydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

Hydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance. Hydraulic Fluids Fluid Types Any type of hydraulic fluids listed in the table below can be used. Petroleum base oils Use fluids equivalent to ISO VG 32 or VG 46. Use phosphate ester or polyol ester fluid.

More information

PRESSURE REDUCING AND RELIEVING VALVES

PRESSURE REDUCING AND RELIEVING VALVES REDUING AND RELIEVING VALVES RBG-3 / 6 (3/8, 3/4) Mounting Specifications / Model Number Designation / Others Up to 25 (363 ), 25 (33 U.S.GPM) reducing and relieving valves are composite pressure control

More information

Pressure Reducing and Relieving Valves

Pressure Reducing and Relieving Valves reducing and relieving valves are composite pressure control valves having pressure reducing and counterbalancing functions developed for hydraulic balancing circuits. Specifications RBG-- * - * RBG-6-

More information

UNLOADING RELIEF VALVES

UNLOADING RELIEF VALVES UNLOADING RELIEF VALVES BUG-6/1 (3/4, 1-1/4) Specifications / Model Number Designation Up to 21 (35 ), L /min (66 ) Pub. E- These valves are used to operate the pumps with minimum load in accumulator circuits

More information

PRESSURE REDUCING AND RELIEVING VALVES

PRESSURE REDUCING AND RELIEVING VALVES REDUING AND RELIEVING VALVES RBG-3 / 6 (3/8, 3/4) Mounting Specifications / Model Number Designation / Others Up to 5 (363 ), (33 U.S.GPM) reducing and relieving valves are composite pressure control valves

More information

SHUT-OFF TYPE SOLENOID OPERATED DIRECTIONAL VALVES DSPC/DSPG-01/03(1/8,

SHUT-OFF TYPE SOLENOID OPERATED DIRECTIONAL VALVES DSPC/DSPG-01/03(1/8, SHUT-OFF TYP SOLNOID OPRATD VALVS DSPC/DSPG-/(/8, /8) Cartridge Type / Mounting Up to 5 MPa (6 PSI), 8 (. U.S.GPM) Pub. C- The shut-off type solenoid operated directional valves are poppet type solenoid

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -

More information

Max. Operating Pressure Kgf/cm 2. F- YB T -01 -F Max. Operating Design Pressure Kgf/cm 2 Number. Panel. Mounting

Max. Operating Pressure Kgf/cm 2. F- YB T -01 -F Max. Operating Design Pressure Kgf/cm 2 Number. Panel. Mounting Remote ontrol Relief Valves his valve is used as a remote control valve for pilot operated type pressure control valves. EI--1-0 Graphic Symbol Specifications hreaded onnection Designation F- YB -01 -F

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -

More information

Vent Connection. Pres. Adj. Range BT BG * ~ BG F- B T -03 P -V -32.

Vent Connection. Pres. Adj. Range BT BG * ~ BG F- B T -03 P -V -32. These valves protect the hydraulic system from excessive pressure, and can e used to maintain constant pressure in a hydraulic system. Remote control and unloading are permitted y vent circuit. PRESSURE

More information

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

G SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) G SERIES SHOCKLESS TYPE "G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS

More information

01 SERIES MODULAR VALVES. Pub. EC-1402

01 SERIES MODULAR VALVES. Pub. EC-1402 SERIES General Information Mounting Surface : ISO --3--, CEO-3, N-D Up to 3.5 Ma (57 SI), 35 L /m in (9.5 U.S.GM) ub. EC- MODULR VLVES he modular valves are functional elements with which a hydraulic system

More information

High Pressure, High Flow Rate Modular Valves

High Pressure, High Flow Rate Modular Valves eatures Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly and easily. roblems such

More information

EMechanically Operated Directional Valves

EMechanically Operated Directional Valves E DIRECIONL CONROLS Cam Operated Directional Valves hese valves may be used to shift the direction of oil flow by depressing the spool by way of a cam. Specifications Max. Operating Max. -Line Max. Flow

More information

Series Proportional Electro-Hydraulic Controls

Series Proportional Electro-Hydraulic Controls Proportional Electro-ydraulic Controls Types Graphic Symbols Max. Operating Pressure () Maximum Flow U.S.GPM. 3 3 3 L/min Page Pilot Relief Valves. (3) EDG 67 Relief Valves. (3) EBG 3 6 676 Relieving and

More information

06 SERIES MODULAR VALVES. Pub. EC-1404

06 SERIES MODULAR VALVES. Pub. EC-1404 6 SERIES General Information Mounting Surface : ISO -AE-8--A, CETOP-8, NPA-D6 Up to 5 MPa (363 PSI), 5 L /m in (3 U.S.GPM) Pub. EC- The modular valves are functional elements with which a hydraulic system

More information

EH SERIES PROPORTIONAL ELECTRO-HYDRAULIC CONTROL VALVES

EH SERIES PROPORTIONAL ELECTRO-HYDRAULIC CONTROL VALVES Pub. EC- E SERIES ELECTRO-YDRAULIC CONTROL VALVES Pilot Relief / Relief / Reducing and Relieving / Flow Control / Flow Control and Relief / Directional and Flow Control Up to. ( PSI), L/min (6 U.S.GPM)

More information

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S. 3 SERIES General Information Mounting Surface : ISO 44-C--4-, CETO-, N-DO Up to Ma (363 SI), 7 L /min (8. U.S.GM) ub. EC-43 MODULR VLVES The modular valves are functional elements with which a hydraulic

More information

Proportional Electro-Hydraulic Pilot Relief Valves

Proportional Electro-Hydraulic Pilot Relief Valves Proportional Electro-Hydraulic This valve consists of a small DC solenoid and a direct-acting relief valve. It serves as a pilot valve for a low flow rate hydraulic system or a proportional electro-hydraulic

More information

FLOW CONTROLS. Maximum Flow U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. Page. Valve Type.

FLOW CONTROLS. Maximum Flow U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. Page. Valve Type. FLOW CONTROLS Valve Type Graphic Symbols Maximum Operating Pressure MPa (PSI) Maximum Flow U.S.GPM 5 5 5 5 5 5 5 Page Flow Control Valves (5) 77 Flow Control and Check Valves (5) 77 Pilot Operated Flow

More information

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating

More information

Proportional Electro-Hydraulic Flow Control and Relief Valves

Proportional Electro-Hydraulic Flow Control and Relief Valves Ω Ω Proportional Electro-ydraulic Flow ontrol and Relief Valves This flow control and relief valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since

More information

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination 3

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination 3 T,T,F SERIES Fixed Displacement-Single, Double, Combination Up to 7 MPa ( PSI), 9 cm /rev (. CU.IN./rev) Single Pumps These pumps are widely used as a source of hydraulic power. They combine stable performance

More information

Restrictors / One Way Restrictors

Restrictors / One Way Restrictors FLOW CONTROLS This valve is used to regulate an actuator speed in a circuit where line pressure is almost steady and small fluctuation of oil flow due to pressure changes is permitted. Integrated check

More information

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination T,T,F SERIES Fixed Displacement-Single, Double, Combination Up to 7 MPa ( PSI), 9 cm /rev (. CU.IN./rev) Single Pumps These pumps are widely used as a source of hydraulic power. They combine stable performance

More information

" " Series Variable Displacement Piston Pumps

  Series Variable Displacement Piston Pumps " " Series Variable Displacement Piston Pumps AR Axial Port Type AR Side Port Type "AR" series variable displacement pump has been developed which the aim of even further the quientness in operation, smaller

More information

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22-FR01

AR SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22-FR01 "AR" SERIES Variable Displacement-Single Pumps Compensator Type, / AR-FR1 Up to 1 MPa ( PSI),. cm /rev ( CU.IN./rev) Pub. EC- A Compensator Valve Adj. Screw Spool Control Piston Drain Port Flow Adj. Screw

More information

10 SERIES MODULAR VALVES. Pub. EC-1405

10 SERIES MODULAR VALVES. Pub. EC-1405 SERIES General Information Mounting Surface : ISO ----, CETOP-, NP-D Up to 5 MPa (363 PSI), 8 L /m in ( U.S.GPM) Pub. EC-5 The modular valves are functional elements with which a hydraulic system can be

More information

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications ilot Operated Directional s DIRECIONL CONROLS hese valves perform a change over of spool by hydraulic pilot and shift the direction of oil flow. EIC-E-04-0 Specifications Model Numbers Maximum Flow L/min.

More information

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct

More information

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22- FR01 3

AR SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22- FR01 3 "AR" SERIES Variable Displacement-Single Pumps Compensator Type,AR / AR- FR Up to MPa ( PSI),. cm /rev (.5 CU.IN./rev) Pub. EC- A Compensator Valve Adj. Screw Spool Control Piston Drain Port Flow Adj.

More information

Pilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves

Pilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves FLOW CONTROLS Flow control of these valves is continuously made by a hydraulically operated pilot piston mechanism which controls opening area of the orifice of the valve. With the use of these valves,

More information

EMulti Purpose Control Valves

EMulti Purpose Control Valves IRCTIONAL CONTROLS The Yuken Multi-Purpose Valves Comply with The Needs of Reducing Cost and Size of Your Machine YUKN's Multi Purpose Valve s are compound valves composed of the main valve having four

More information

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8 DIRCINL CNRLS Manually perated Directional s hese valves may be used to manually shift the spool position and change the direction of oil flow. IC--1005-0 Specifications Numbers DMG-01-C -10 DMG-01-D -10

More information

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS H PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS Hydraulic Controls H-3 H-1 E Series Hydraulic Controls Hydraulic Controls Max. Maximum Flow Types KS Graphic Symbols Operating L/min 1 2 3 5 10 20 30 50 100 200

More information

Throttle Modules / Throttle and Check Modules

Throttle Modules / Throttle and Check Modules FLOW CONTROLS Used as pilot choke valves for solenoid controlled pilot operated directional valves and pilot operated directional valves. Graphic Symbols Valve Size 3 Standard Type P AB T TCG- P A B T

More information

Direct Operated Type Directional and Flow Control Valves

Direct Operated Type Directional and Flow Control Valves Specifications igh Response Type Proportional Electro-ydraulic Directional and Flow Control Valves igh response, high precision and high reliability are achieved be a combination of a compact and powerful

More information

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS H PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS Hydraulic Controls H-3 H-1 E Series Hydraulic Controls Hydraulic Controls Max. Maximum Flow Types KS Graphic Symbols Operating L/min 1 2 3 5 10 20 30 50 100 200

More information

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts ydraulic Relief s The electro hydraulic relief valve is designed for compactness and high efficiency. The valve provides fast proportional response to the input current. For linear pressure control a special

More information

Proportional Electro-Hydraulic Flow Control (and Check) Valves

Proportional Electro-Hydraulic Flow Control (and Check) Valves Ω Proportional Electro-ydraulic Flow Control (and Check) Valves Since the preselected flow rate continuously varies in proportion to the current input to the valve, the system flow rate can be remotecontrolled

More information

Poppet Type Directional Valves

Poppet Type Directional Valves IRCTIONAL CONTROLS Poppet Type irectional Valves Valve Type Graphic Symbols Max. Operating Pressure MPa (PSI) Maximum Flow U. S. GPM.5 5 5 5 5 5 L/min Page Poppet Type Solenoid Operated irectional Valves

More information

PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS

PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS H PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS -Hybrid Components...Page Proportional Electro-Hydraulic Control Valves...Page 7 Proportional Electro-Hydraulic Controls High-accuracy, simple, convenient realizes

More information

"A" Series Variable Displacement Piston Pumps Single Pump, Pressure Compensator Type

A Series Variable Displacement Piston Pumps Single Pump, Pressure Compensator Type A"A" Series PISTON PUMPS Single Pump, Compensator Graphic Symbol M O Specifications Model s A-FRB- A-FRC/H- A- -R-- - -K- A- -R-- - -K- A- -R-- - -K- A- -R-- - -K- A- R S- A9- R S- A- R S- Geometric Displacement

More information

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance. PRESSURE CONTROLS Fluid Types Any type of hydraulic fluids listed in the table below can be used Petroleum base oil Synthetic Fluids Water Containing Fluids Use equivalent to ISO VG32 or VG46. Use phosphate

More information

" " Series Variable Displacement Piston Pumps

  Series Variable Displacement Piston Pumps " " Series Variable Displacement Piston Pumps Compensator Type Constant Power (Torque) Control Type Load Sensing Type Pump Type Graphic Symbol Geometric Displacement cu. in./rev...5 5 5 5 5 cm /rev Maximum

More information

AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps

AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps Variable Displacement Piston Pumps AR Series Variable Displacement Piston Pumps Geometric Displacement Maximum cm 3 /rev Operating Pump Type Graphic Symbol Pressure Page 1 2 5 10 20 50 100 150 MPa Variable

More information

A Series Variable Displacement Piston Pumps

A Series Variable Displacement Piston Pumps A Series Variable Displacement Piston Pumps A37 A56 A1637 A16 A10 A Series Variable Displacement Piston Pumps Pump Type Graphic Symbol Geometric Displacement cm 3 /rev 1 5 10 0 50 100 00 300 Maximum Operating

More information

High Pressure, High Flow Rate Modular Valves

High Pressure, High Flow Rate Modular Valves High Pressure, High Modular Valves EIC-F-14- MODULR VLVES The modular valves are functional elements with which a hydraulic system can be composed and built easily by stacking them with the mounting bolts.

More information

Modular Valves. Ratings

Modular Valves. Ratings High Pressure, High Flow Rate Features Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly

More information

Proportional Electro-Hydraulic Directional and Flow Control Valves

Proportional Electro-Hydraulic Directional and Flow Control Valves Proportional Electro-Hydraulic s These valves are double-deck directional and flow control valves employing as their pilot the electro-hydraulic proportional pressure reducing valves with two proportional

More information

10 SERIES MODULAR VALVES

10 SERIES MODULAR VALVES General Information Mounting Surface : ISO 441-A-1-4-A, CETOP-1, NPA-D1 Up to 5 MPa (363 PSI), 8 L /min (11 U.S.GPM) Pub. EC-145 The modular valves are functional elements with which a hydraulic system

More information

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts s The electro hydraulic relief valve is designed for compactness and high efficiency. The valve provides fast proportional response to the input current. For linear pressure control a special venting feature

More information

Max. Operating Pressure Kgf/cm 2

Max. Operating Pressure Kgf/cm 2 In-Line Check Valves DIRCTIONAL CONTROLS These valves allow free flow in one direction and prevent flow in the reverse direction. Cracking pressure specified is the pressure required to open the valve

More information

Directional Controls

Directional Controls VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................

More information

Flow Control Valves / Flow Control and Check Valves

Flow Control Valves / Flow Control and Check Valves LOW CONTROLS These valves are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (viscosity of the fluid).

More information

VANE PUMPS. Output Flow at 1200 r/min at No-Load U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols.

VANE PUMPS. Output Flow at 1200 r/min at No-Load U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. B VANE PUMPS Pump Type "PVR" Series Single Pumps Graphic Symbols at r/min at No-Load.. PVR PVR PVR PVR Maximum Operating MPa (PSI) () Page Fixed Displacedment "PVRA" Series Single Pumps "PVR" Series Double

More information

ISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090

ISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090 Spare Parts List PVR-* - * -RAA-4/4 PVR-* - * -RAA-4/4 PVR-* - * -RAA-/ PVR4-* - * -RAA-/ 4 5 4 6 8 8 6 5 4 Y Section Y-Y Y 6 5 Section - 8 Cartridge Kits Model Numbers PVR-6- * -RAA-4 * PVR-8- * -RAA-4

More information

Max. Reversed Free Flow. Max. Operating. Pressure MPa (PSI) Fine Feed 20 (5.3) 14 (2030) 40 (10.6) ( ) 40 (10.6) (

Max. Reversed Free Flow. Max. Operating. Pressure MPa (PSI) Fine Feed 20 (5.3) 14 (2030) 40 (10.6) ( ) 40 (10.6) ( These valves are the combination of flow control valve, a deceleration valve and a check valve and used mainly for controlling rapid traverse and feed cycles machine tools. Switching from rapid traverse

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Controls

Directional Controls VICKERS Directional Controls DG3V-7, 20 Series, ilot Operated DG5V-7, 40 Series, Solenoid Controlled, ilot Operated ISO 440 Size 07 ypical Section DG5V-7-2C Spring-Centered Valve Example Basic Characteristics

More information

VARIABLE DISPLACEMENT PISTON PUMPS

VARIABLE DISPLACEMENT PISTON PUMPS VRIBLE DISPLCEMENT Pump Type "R" Series Variable Displacement Piston Pumps Maximum Operating MPa (PSI) () Geometric Displacement cu. in./rev... cm /rev R R Catalogue No. Pub. EC- "" Series Variable Displacement

More information

A Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics.

A Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics. EIC--12- PISTON PUMPS Series Variable Features High efficiency Under the conditions of pressure 16 Kgf/cm² and speed 18 r/min. volumetric efficiency is over 98% and the overall efficiency is over 9%. Low

More information

Proportional Electro-Hydraulic Relieving and Reducing Valves

Proportional Electro-Hydraulic Relieving and Reducing Valves These valves consist of a small size but high performance EH series electro-hydraulic proportional pilot relief valve and reducing valve with relief function. The valves control the system pressure proportionally

More information

AR Series Variable Displacement Piston Pumps. [Comparison of AR16 with A16 ] A16,32 Design 188. AR16,22 Design 130. Ratio of Mass (AR16/A16) 74%

AR Series Variable Displacement Piston Pumps. [Comparison of AR16 with A16 ] A16,32 Design 188. AR16,22 Design 130. Ratio of Mass (AR16/A16) 74% PISTON PUMPS EIC--11- Features Smaller in Size and Lighter in Mass s indicated in the dimensional comparison presented below, the R1 is smaller than the 1(3 design). lso, the mass of R1 is substantially

More information

Variable Displacement Piston Pumps

Variable Displacement Piston Pumps A3HG Series High Pressure Variable Displacement Piston Pumps A3HG71 A3HG1 A3HG Through Drive A3HG Series High Pressure Variable Displacement Piston Pumps Pump Type Graphic Symbol Geometric Displacement

More information

"PV11R" SERIES Fixed Displacement- Single PV11R10/PV11R20

PV11R SERIES Fixed Displacement- Single PV11R10/PV11R20 "PVR" SERIES Fixed Displacement- Single PVR/PVR Up to MPa ( ),. cm /rev (. CU.IN./rev) Pub. EC- These pumps are of completely unique design for extra high pressure applications. The excessive wear to the

More information

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31. F MODULES YUKEN's are stack type valves, and require no piping. They not only rationalise system build, but they also meet the technical requirements for a variety of hydraulic systems. Stacking systems

More information

5.2 to 79 gpm 3000, 3600, 5000 psi

5.2 to 79 gpm 3000, 3600, 5000 psi Modular Valve Series Modular Valve Series. to 79 gpm 000, 600, 000 Overview he modular valve is designed and engineered to integrate multiple hydraulic valve operations into a single unit, which eliminates

More information

NDR Series Rotor Pack

NDR Series Rotor Pack efore using the product, please check the DR Series Rotor ack Features Low noise chieves a noise level of no greater than 0 d () and there is no need to worry about hydraulic noise even at factories in

More information

ARL1 Series Piston Pumps. ARL1 Series Piston Pumps. Geometric Displacement. Maximum cm 3 /rev

ARL1 Series Piston Pumps. ARL1 Series Piston Pumps. Geometric Displacement. Maximum cm 3 /rev ARL1 Series Piston Pumps Geometric Displacement Maximum cm 3 /rev Operating Pump Type Graphic Symbol Pressure Page 1 2 5 10 20 50 100 150 MPa ARL1-6 Piston Pump ARL1-8 ARL1-12 7 8 ARL1-16 5 Hydraulic Fluids

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D61VW General Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D101VW General Series D101VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are

More information

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min. Flow Control These are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (Viscosity of the fluid). They

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2502/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

EHBG-03 EHBG-06 EHBG-10. Refer to Model No. Designation. 2% or Less(1%) 1% or Less *2. Refer to frequency Response on page V DC

EHBG-03 EHBG-06 EHBG-10. Refer to Model No. Designation. 2% or Less(1%) 1% or Less *2. Refer to frequency Response on page V DC Proportional Electro-ydraulic These valves, consist of a small size but high performance E series electro-hydraulic proportional pilot relief valve and a low noise type relief valve. The valves control

More information

Modular Throttle Valve MST MT MTC MCT Solenoid Operated Throttle Valve Throttle Valve Throttle and Check Valve Counter Restrictors Valve

Modular Throttle Valve MST MT MTC MCT Solenoid Operated Throttle Valve Throttle Valve Throttle and Check Valve Counter Restrictors Valve Modular Throttle MST MT MTC MCT Solenoid Operated Throttle Throttle Throttle and Check Counter Restrictors Modular Relief MGS MBR MCB MRB MSV MRV Two Section Reducing Reducing Counter Balance Balance Sequence

More information

Series Variable Displacement Piston Pump

Series Variable Displacement Piston Pump AH Series Variable Displacement Piston Pump AH AH7 AH AH45 KS Geometric Displacement Max. Operating Series Graphic cm 3 /rev Pres. Page Symbol 3 4 5 6 7 8 9 3 4 5 MPa {kgf/cm 2 } AH-F-R--K-S- AH AH45-F-R--K-S-

More information

PISTON PUMPS. A3H Series High Pressure Variable Displacement Piston Pumps. Features. A3H Series Variable Displacement Piston Pumps.

PISTON PUMPS. A3H Series High Pressure Variable Displacement Piston Pumps. Features. A3H Series Variable Displacement Piston Pumps. 3H Series High Variable EIC--13- Features 1 Control System for Wide Range pplication: 1 Compensator Type 3H Series High Variable 9 Constant Power Control Type 1 Load Sensing Type For these controls system,

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Solenoid directional valves type DPHI, DPHU

Solenoid directional valves type DPHI, DPHU www.atos.com Table E0805/E Solenoid directional valves type, two stage, ISO 4401 size 10, 16, 25 and 32 37**/HM..... and are spool type, two or three position directional two stage solenoid valves designed

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.

More information

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Application. Features. Operation. Catalog HY14-2500/US Introduction pplication Series D101 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

"A" Series Piston Pumps Variable Displacement-Single Pumps Electro-Hydraulic Proportional Pressure & Flow Control. Type

A Series Piston Pumps Variable Displacement-Single Pumps Electro-Hydraulic Proportional Pressure & Flow Control. Type Variable Displacement-Single Pumps Electro-Hydraulic Proportional & Flow Type 6 / / 7 / 6 / 7 / 9 / Model Number Designation Safety valve Input Signal for Flow Input Signal for mplifier Proportional Solenoid

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

Model (kg) CIT CRG-06 CIT : CIT CRG-10 CIT : CIT CIT

Model (kg) CIT CRG-06 CIT : CIT CRG-10 CIT : CIT CIT check valve OUT IN RG - 06-5 1 3 1 RG: Sub-plate mounting IT: Thread connection Valve size 03: 3/8" 04: 1/" 06: 3/4" 08: 1" 10: 1-1/4" 1: 1-1/" 16: " 3 racking pressure (bar) 5: 0.5 50: 5 Rated Flow Max.

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position

More information

Max. Reversed Free Flow L/min

Max. Reversed Free Flow L/min These Valves are the combination of flow control valve, a deceleration valve and a check valve and used mainly for controlling rapid traverse and feed cycle in machine tools. Switching from rapid traverse

More information

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA Series V irect Operated Port Solenoid Valve for Oil Series V VX VN V VW V V P.-9 Multipurpose Valve for Oil irect Operated Port Solenoid Valve for Oil Series V Kerosene, uel oil class (fuel oil ), Silicone

More information

Differential Lock Valve

Differential Lock Valve Differential Lock Valve Series M..DVV (for 4 motors) robust and reliable energy-optimised over the whole flow range simple control compact design offers space-saving installation reliable, uniform motion

More information

Pump Safety Block Model DBA... / DBAW, Series 1X

Pump Safety Block Model DBA... / DBAW, Series 1X ump Safety lock odel D... / DW, Series X Sizes to 6 SI ( bar) 7 G (65 L/min) R 5 88/.95 Replaces:.9 ermits low pressure start-up and by-pass of pump Direct mounting to SE pressure port of pump Light biasing

More information

Directional Control Valves

Directional Control Valves echnical Information General Description he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available

More information

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire ulletin 2544-1/US Introduction pplication arker D1M Series hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3 position styles. hey are

More information

Bankable Control Valves

Bankable Control Valves Hydraulics ankable Control Valves Catalog 3123/US Catalog 3123/US Contents ankable Control Valves WRNING FILURE OR IMROER SELECION OR IMROER USE OF HE RODUCS ND/OR SYSEMS DESCRIED HEREIN OR RELED IEMS

More information