EMulti Purpose Control Valves
|
|
- Sharlene Cain
- 5 years ago
- Views:
Transcription
1 IRCTIONAL CONTROLS The Yuken Multi-Purpose Valves Comply with The Needs of Reducing Cost and Size of Your Machine YUKN's Multi Purpose Valve s are compound valves composed of the main valve having four poppets, / Solenoid Operated irectional Valves for pilot and Pilot Selector Valves. This valve is multifunctionalized by having individual poppet had functions such as directional control, flow control or pressure control according to the combination of the main valve and pilot selector valve. Features Multi-purpose control valves The valves combine three functions of directional control, flow control and of pilot operated check valve (or counterbalance valve). The valves contribute for reducing a number of valves in applications and space for installation and then eventually leads to reduction in size and cost of your machines. Quick response, High reliability Changeover response time is very quick as the valves are poppet type, there is no over-lap. No hydraulic lock occurs as there is no leakage of pressurised oil from the seat parts. asy to reduce shock in your hydraulic system By selecting proper diameter of orifice for pilot, the open/close timing of the flow passage can be set freely. Therefore, smooth starting and stopping of actuator can be done combined with using shockless type poppet. Noise of ON/OFF and vibration of piping in hydraulic system can be also reduced. For regenerative circuit position- way type, which is to compose regenerative circuit, is available. By adopting regenerative circuit, gaining fast feed speed by using smaller volume pump is possible. Therefore saving electric power of system is possible. The mounting dimensions are conformed with ISO standard The valves are interchangeable with our conventional valves in mounting. Solenoid Operated irectional Valve for Pilot Orifice By selecting proper diameter of orifice for pilot, the open/close timing of the flow passage can be set freely. Pilot Selector Valve X Y Section X-X X T T Y Section Y-Y A B Flow Adjustment Screw P Main Valve Seat Spring Shockless Type Poppet 9
2 Specifications SLHG--- - SLHG--- - SLHG--- - SLHG SLHG SLHG SLHG SLHG SLHG SLHG SLHG--- - SLHG--- - SLHG--- - SLHG SLHG Max. Flow L/min (U.S.GPM) (9.6) {} (9.6 {6.}) (79.) {} (79. {.}) () {} ( {79.}) Max. Operating Pressure MPa (PSI) Max. Pilot Pressure MPa (PSI) Max. T-Line Back Pres. MPa (PSI) (6) (6) 6 () (6) (6) 6 () (6) (6) 6 () In case of counterbalance function line, maximum flow is limited to the values in brackets. Pressure Adj. Range of Counterbalance MPa (PSI) Refer to Model No. esignation Refer to Model No. esignation Refer to Model No. esignation Ratio of Poppet Area (Seat Area: Annular Area) irection & Flow : Pressure : : : : : : : : Approx. Mass kg (lbs.) () () 9 () (). () 6. (9) 6. (9) (6) (6). (76) 9 () 9 () 6 (7) 6. () 67 () Solenoid Ratings Refer to Pilot Valve (SG- Series Solenoid Operated irectional Valve) Solenoid Ratings on page. Model Number esignation F- Special Seals SLH Series Number F: SLH: For phosphate Multi-Purpose ester type fluids Valve (Omit if not required). See "Min. Adjustment Pressure", page 6, for information on minimum adjustment pressure. G Type of Mounting G: Sub-plate Mounting - Valve Size 6 - Type of Pilot A Counterbalance Function A : AT Line W: AT & BT Lines A : AT Line W: AT & BT Lines A : AT Line W: AT & BT Lines See page 6 for functions and purpose of use. -B Pressure Adj. Range of Counterbalance MPa (PSI) B : - 7 ( - ) H : 6 - (7-6) None: None: - ( - 6) - ( - 6) 6
3 IRCTIONAL CONTROLS Sub-plate Valve Model Numbers SLHG- SLHG-6 SLHG- Japanese Standard "JIS" uropean esign Standard N. American esign Standard Sub-plate Model Numbers HGM-- HGM-X- HGM-6- HGM-6X- HGM-- HGM-X- Thread Size Rc / Rc / Rc / Rc Rc -/ Rc -/ Approx. Mass kg (lbs.) (9.7) (9.) (6.) (6.). (7.). (7.) Sub-plate Model Numbers HGM-- HGM-X- HGM-6- HGM-6X- HGM-- HGM-X- Thread Size / BSP.F / BSP.F / BSP.F BSP.F -/ BSP.F -/ BSP.F Approx. Mass kg (lbs.).... (9.7) (9.) (.7) (.7). (7.). (7.) Sub-plate Model Numbers HGM--9 HGM-X-9 HGM-6-9 HGM-6X-9 HGM--9 HGM-X-9 Thread Size / NPT / NPT / NPT NPT -/ NPT -/ NPT Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should have a good machined finish. These sub-plates are sharable with those for SHG Series Solenoid led Pilot Operated irectional Valve. For dimensions, see pages to. Approx. Mass kg (lbs.) (9.7) (9.) (6.) (6.). (7.). (7.) Mounting Bolts Socket head cap screws in the table below are included. Socket Head Cap Screw Model Numbers Japanese Standard "JIS" and N. American esign Standard Qty. uropean esign Standard SLHG- SLHG-6 SLHG- M6 Lg. M Lg. /- UNC -/ Lg. /-6 UNC -/ Lg. M 6 Lg. /- UNC -/ Lg. M 7 Lg. /- UNC Lg. 6 6 Tightening Torque Nm (In. lbs.) - (6-) -7 (-67) - (-9) 7- (6-77) - Pilot Connection T rain Connection -A Coil Type -C Manual Override -N lectrical Conduit Connection - esign Number esign Standards None: Internal Pilot : xternal Pilot None: xternal rain T: Internal rain AC: A A A A C: R: (AC C) R R None: Manual Override Pin C: Push Button & Lock Nut (Options) None: Terminal Box Type N: Plug-in Connector Type None: Japanese Std. "JIS" 9: N.American esign Std. None: Japanese Std. "JIS" & uropean esign Std. 9: N.American esign Std.. In case of lines with counterbalance function (- A A W, - W ), xternal rain must be selected for rain Connection. The coil type numbers in the shaded column are handled as optional extras. In case these coils are required to be chosen, please confirm the time of delivery with us before ordering. 6
4 Function and Purpose of Use Type of Pilot Model No. Graphic Symbols irectional Function Flow Pilot Operated Check Valve Pressure Purpose of Use Type "" SLHG- - b a # # # AB Functions as Three Position Four-Way Valve (Spring Centred Model). Type "" Type "" SLHG- - SLHG- - T A P B Y b a T A P B Y a b T A P B Y PT Position # # # ON OFF OFF OFF OFF ON # # # # AB PT Position # # # # ON OFF ON OFF OFF OFF ON ON A B irectional P T Both Metre-in and Metre-out are possible A B irectional P T To get a function of pilot operated check valve, the following conditions should be fulfilled. Internal pilot type ("P" port pressure) >= ("A""B" ports pressure) xternal pilot type (Pilot pressure) >= ("A""B" ports pressure) Functions as Three Position Four-Way Valve (Spring Centred Model) as well as Two Position Valve which uses positions # and #. ffective especially when the actuator has inertia force. Functions as Four Position Four-Way Valve. Regenerative circuit can be constructed at the Position #. Type "" SLHG- -A SLHG- -W b a T A P B Y b a T A P B Y # # # AB PT Position # # # ON OFF OFF OFF OFF ON A B irectional P T A B irectional P T A B irectional P T A B irectional P T Pressure control function (counterbalance valve) has been added to Type "" to make this type. Used to control the back pressure of the actuator. a b Type "" SLHG- -A SLHG- -W T A P B Y a b # # # # AB PT Position # # # # ON OFF ON OFF OFF OFF ON ON A B irectional P T A B irectional P T A B irectional P T A B irectional P T Pressure control function (counterbalance valve) has been added to Type "" to make this type. Used to control the back pressure of the actuator. T A P B Y 6
5 IRCTIONAL CONTROLS Instructions Pilot Pressure Pilot pressure of external pilot drain models must always exceed the pressure of the main pressure port "P". Pilot rain Port Avoid connecting the pilot drain port to a line with possible surge pressure. rain Connection when with Counterbalance Function When a valve having counterbalance function is used with internal drain type, the counterbalance pilot valve is subjected to pressure fluctuation and the pressure setting becomes unstable. For this reason, be sure to use external drain type valve. Flow Adjustment To perform the flow adjustment, loosen the lock nut, then turn the flow adjustment screw clockwise to decrease the flow. Be sure to re-tighten the lock nut after the adjustment. Pressure Adjustment To perform the pressure adjustment, loosen the lock nut, then turn the pressure adjustment screw clockwise to increase the pressure. Be sure to re-tighten the lock nut after the adjustment. Min. led Flow for Types "" and "A" at The Time of Metre-out Minimum controlled flow at the time of metre-out control is limited (this does not happen during metre-in control) as shown in the figure below only in the case of pilot control types "" (SLHG- -) and "A" (SLHG- -A). Min. led Flow for Types "" and "A" at The Time of Metre-out U.S.GPM L/min SLHG-- Min. Flow Rate SLHG-6- SLHG--, SLHG- 6-A SLHG--A 6 MPa ifferential Pressure PSI 6
6 Pressure rop Hydraulic Fluid: Viscosity m m /s (6 SSU), Specific Gravity. Pressure rop P PSI 7 SLHG- MPa.. P A, P B.6.. A T, B T 6 L /min Pressure rop P PSI 7 MPa SLHG-6 P A P B A T B T L /min Pressure rop P PSI 7 MPa SLHG- B T P A, P B A T L /min Flow Rate U.S.GPM 6 7 Flow Rate U.S.GPM 6 Flow Rate U.S.GPM For any other viscosity, multiply the factors in the table below. Viscosity Factor mm /s SSU For any other specific gravity (G'), the pressure drop ( P') may be obtained from the formula below. P'= P (G'/.) Flow vs. Adjustment Revolutions U.S.GPM Flow Rate L /min SLHG- P: ifferential Pres. P=MPa(PSI) P=() P=() 6 P=7() P=() P=.() 6 Fully Position Closed (Number of Turns) U.S.GPM Flow Rate 7 6 L /min SLHG-6 SLHG- P: ifferential Pres. U.S.GPM L /min P: ifferential Pres. P=MPa(PSI) P=() P=() P=7() P=() P=.() 6 Fully Closed Position (Number of Turns) Flow Rate 6 P= () P= () P=MPa(PSI) P=7() P=() P=.() 6 7 Fully Position Closed (Number of Turns) Minimum Adjustment Pressure Because the minimum adjustment pressure varies with the tank line back pressure, add the tank line back pressure to the value on the following lines. PSI MPa. SLHG-- PSI MPa. SLHG-6- PSI MPa. SLHG-- Min. Adj. Pressure.. 7 L /min Min. Adj. Pressure.. L /min Min. Adj. Pressure.. L /min Flow Rate U.S.GPM Flow Rate U.S.GPM 6 Flow Rate U.S.GPM 6
7 IRCTIONAL CONTROLS SLHG-- - -/9 Tank Port "T" Pressure Port "P" Terminal Box Type SLHG--- -/9 Mounting Surface: ISO -A-7--A Fully xtended 77(.9) Fully xtended.6(.) 96(.7).(.) Pilot Pressure Port "X" (For xternal Pilot Type only) (.) 69.9 (.7) 69.9 (.7) 9 (.) lectrical Conduit Connection "C" Thd. (Both nds) (.) 99(.9) (.9) (.) ia. Through 7.(.69) ia. Spotface Places Cylinder Port "A" (.97).6 (.6) Pilot rain Port "Y" 7(.) ia. Through (.) ia. Spotface Places (For xternal rain Type only) Cylinder Port "B" C/R :.(.) lectrical Conduit Connection AC : 96.(7.7) "C" Thd. (Both nds) 9(.7) C/R :.7(.) AC :.7(.) (.6) 7 (.7) 9. (7.6). (9.6). (.9) 7 (.6) (.) 6 (.) Manual Actuator 6(.) ia. SLHG SLHG (.) 6. (.7). (.9) For other dimensions, see "SLHG-- " drawing left. "C" Thd. G / / NPT Lock Nut 7(.67) Hex. (.) Hex. Soc. C. Mounting Surface (s Furnished) (.6) (.) ia. Two Locating Pins IMNSIONS IN MILLIMTRS (INCHS) SLHG--W- - -/9 SLHG--A- - -/9 Lock Nut (.) Hex. (.) Hex. Soc. INC. Lock Nut 7(.67) Hex. (.). (.) 6. (.6) 7. (.9) (.) Hex. Soc. C. Fully xtended 96(.7) Fully xtended.(.) For other dimensions, see "SLHG-- " drawing above. SLHG--W- - -/9 (.) 99(.9) (.9) 7 (.7) Fully xtended 77(.9) For other dimensions, see "SLHG--W" drawing left. SLHG--A- - -/9 Lock Nut (.) Hex. (.) Hex. Soc. INC. Lock Nut 7(.67) Hex. (.) Hex. Soc. C. Fully xtended 96(.7) Fully xtended.(.) For other dimensions, see "SLHG-- " drawing above. 6(.) 6. (.). (.) 6. (.7) Fully xtended 77(.9) For other dimensions, see "SLHG--W" drawing left. 6
8 SLHG-- - -N-/9 Plug-in Connector Type Mounting Surface: ISO -A-7--A Tank Port "T" Fully xtended 77(.9) Fully xtended.6(.) 96(.7). (.) Pressure Port "P" Pilot Pressure Port "X" (For xternal Pilot Type only) (.) ia. Through 7.(.69) ia. Spotface Places Cylinder Port "A" (.97) 7(.) ia. Through (.) ia. Spotface Places C/R :.(.) AC : 96.(7.7) (.) C (.) 69.9 (.7).6 (.6) 7. (.) 9(.) Pilot rain Port "Y" (For xternal rain Type only) Cylinder Port "B" C/R :.7(.) AC :.7(.) Cable eparture Cable Applicable: Outside ia mm (. -.9 in.) Conductor Area... Not xceeding.mm (. sq. In) F The position of the Plug-in connector can be changed as illustrated left by loosening the lock nut. After completion of the change, be sure to tighten the lock nut with the torque as specified left. (.6) 7(.7) 9.(7.6) (.) Manual Actuator 6(.) ia. Lock Nut 7(.67) Hex. (.) Hex. Soc. C. Mounting Surface (s Furnished) (.6) (.) ia. Two Locating Pins SLHG-- -A -N SLHG-- - -N SLHG-- -R -N imensions mm (Inches) C F 9 (.) 9 (.) (.9) (.9) 6 (.) 7. (.).(.) 69.(.6) 7.(.7) 7. (.) 7. (.) (.) SLHG--- -N-/9 (.) 99(.9) (.9) 6. (.) SLHG---A -N SLHG--- -N SLHG---R -N imensions mm (Inches) (.9) 6 (.) 7. (.). (.) 9. (.) 99. (.6) For other dimensions, see "SLHG-- - -N" drawing above. IMNSIONS IN MILLIMTRS (INCHS) 66
9 IRCTIONAL CONTROLS Plug-in Connector Type Mounting Surface: ISO -A-7--A SLHG--W- - -N-/9 SLHG--A- - -N-/9 Lock Nut (.) Hex. (.) Hex. Soc. INC. Lock Nut 7(.67) Hex. (.) Hex. Soc. C. (.). (.) 7 (.7) Fully xtended 96(.7) Fully xtended.(.) Fully xtended 77(.9) SLHG--W- -A -N SLHG--W- - -N SLHG--W- -R -N imensions mm (Inches) (.9) 7. (.96) 6 (.) 9. (.) 7. (.) 9. (.) For other dimensions, see "SLHG--W- - -N" drawing left. For other dimensions, see SLHG-- - -N on the previous page. SLHG--W- - -N-/9 SLHG--A- - -N-/9 (.) 99(.9) (.9) Lock Nut (.) Hex. (.) Hex. Soc. INC. Lock Nut 7(.67) Hex. 6. (.) (.) Hex. Soc. C. 6 (.) Fully xtended 96(.7) Fully xtended.(.) Fully xtended 77(.9) SLHG--W- -A -N SLHG--W- - -N SLHG--W- -R -N imensions mm (Inches) (.9) 6. (.) 6 (.) 7. (.) 7. (.). (.) For other dimensions, see SLHG-- - -N on the previous page. For other dimensions, see "SLHG--W- - -N" drawing left. IMNSIONS IN MILLIMTRS (INCHS) 67
10 Tank Port "T" Fully xtended (.7) Fully xtended. 97.(.) (.). (.9) Pressure Port "P" Terminal Box Type SLHG /9 SLHG-6-- -/9 Pilot rain Port "Y" (For xternal rain Type only) Mounting Surface: ISO-A---A lectrical Conduit Connection "C" Thd. (Both nds) 99(.9) (.) (.9) Pilot Pressure Port "X" (For xternal Pilot Type only).(.) ia. Through (.79) ia. Spotface 6 Places 77 (.) C/R :.(.) AC : 96.(7.7) 9(.7) Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. Cylinder Port "B" Cylinder Port "A" 6. (.) 9. (.6) (.6) lectrical Conduit Connection "C" Thd. (Both nds) C/R :.7(.) AC :.7(.) (.97) 9(.) Mounting Surface (s Furnished). (.6) 6. (.). (.7) 6 (.) Manual Actuator 6(.) ia. 7 (.6) 6(.) ia. Two Locating Pins (.6) 6 (.). (9.). (.6) 6. (.) For other dimensions, see "SLHG-6- " drawing left. "C" Thd. SLHG G / SLHG / NPT IMNSIONS IN MILLIMTRS (INCHS) SLHG-6-W- -/9 Lock Nut (.) Hex. (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. Fully xtended 9(.7) 6 (6.). (9.). (.6) 6. (.) SLHG-6-A- -/9 Fully xtended.(6.) SLHG-6-W- -/9 Lock Nut (.) Hex. For other dimensions, see "SLHG-6- " drawing above. Fully xtended 9(.7) (.) 99(.9) (.9) For other dimensions, see "SLHG-6-W" drawing left. SLHG-6-A- -/9 Fully xtended.(6.) (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. 6(6.) 96. (.67). (.) 6. (.) For other dimensions, see "SLHG-6- " drawing above. For other dimensions, see "SLHG-6-W" drawing left. 6
11 IRCTIONAL CONTROLS SLHG N-/9 Tank Port "T" Fully xtended (.7) Fully xtended.(.) 97.(.). (.9) Plug-in Connector Type Pressure Port "P" Pilot rain Port "Y" (For xternal rain Type only) Mounting Surface: ISO-A---A Pilot Pressure Port "X " (For xternal Pilot Type only).(.) ia. Through (.79) ia. Spotface 6 Places 77 (.) C/R :.(.) AC : 96.(7.7) (.) C 6. (.) 9.(.6) Cylinder Port "B" Cylinder Port "A" C/R :.7(.) AC :.7(.) Cable eparture Cable Applicable: Outside ia mm (. -.9 in.) Conductor Area... Not xceeding.mm (. sq. In) F Manual Actuator 6(.) ia. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. (.97) 9(.). (.6) 7 (.6) (.6) Mounting Surface (s Furnished) 6(.) ia. Two Locating Pins 6 (.) SLHG-6-- -N-/9 SLHG-6- -A -N SLHG N SLHG-6- -R -N imensions mm (Inches) C F (.9). (.6) 6 (.) 9. (.9) 7. (.) 97. (.7) 9 (.) 9 (.) (.9) 7. (.) 7. (.) (.) Position of cable departure can be changed. For the details, refer to SLHG- valve on page 66. (.) 99(.9) (.9).(9.) SLHG-6--A -N SLHG-6-- -N SLHG-6--R -N imensions mm (Inches) (.9) 6 (.) 7. (.) 6. (.7) 7. (.). (.6) For other dimensions, see "SLHG N" drawing above. IMNSIONS IN MILLIMTRS (INCHS) 69
12 Plug-in Connector Type Mounting Surface: ISO-A---A SLHG-6-W- -N-/9 SLHG-6-A- -N-/9 Fully xtended 9(.7) Fully xtended.(6.) Lock Nut (.) Hex. (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. 6 (6.). (9.) SLHG-6-W-A -N SLHG-6-W- -N SLHG-6-W-R -N imensions mm (Inches) (.9) 6 (.) 7. (.) 6. (.7) 7. (.). (.6) For other dimensions, see "SLHG-6-W- -N" drawing left. For other dimensions, see SLHG N on the previous page. SLHG-6-W- -N-/9 SLHG-6-A- -N-/9 Fully xtended 9(.7) (.) 99(.9) (.9) Fully xtended.(6.) Lock Nut (.) Hex. (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. 6 (6.) 96. (.67) SLHG-6-W-A -N SLHG-6-W- -N SLHG-6-W-R -N imensions mm (Inches) (.9) 6. (.) 6 (.) 7. (.67) 7. (.) 7. (.7) For other dimensions, see SLHG N on the previous page. For other dimensions, see "SLHG-6-W- -N" drawing left. IMNSIONS IN MILLIMTRS (INCHS) 7
13 IRCTIONAL CONTROLS Fully xtended (7.) Fully xtended 9.(7.) 6.7(.) 76.(.) Tank Port "T".(.) ia. Through (.6) ia. Spotface 6 Places Pilot Pressure Port "X" (For xternal Pilot Type only) 6(.) Hex. Soc. C. Lock Nut 9(.7) Hex.. (.) Pressure Port "P" 79. (.).(6.) Cylinder Port "B" Cylinder Port "A" Terminal Box Type Pilot rain Port "Y" (For xternal rain Type only) C/R :.(.) lectrical Conduit Connection AC : 96.(7.7) "C" Thd. (Both nds) 9(.7) C/R :.7(.) 6 AC :.7(.) (.) 7 (.) (.). (.). (.9). (.) (.77) 7 (.6) Manual Actuator 6(.) ia. Mounting Surface: ISO -AF---A SLHG-- - -/9 SLHG--- -/9 9(7.) lectrical Conduit Connection "C" Thd. (Both nds). (.). (.) SLHG SLHG (.7) (.) "C" Thd. G / / NPT 99(.9) (.9) For other dimensions, see "SLHG-- " drawing left Mounting Surface (s Furnished) 6 (.) 6(.) ia. Two Locating Pins IMNSIONS IN MILLIMTRS (INCHS) SLHG--W- -/9 SLHG--A- -/9 Lock Nut (.) Hex. (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. Fully xtended 9(.7) (9.). (.). (.) 7. (.7) Fully xtended.(6.) For other dimensions, see "SLHG-- " drawing above. For other dimensions, see "SLHG--W" drawing left. SLHG--W- -/9 Fully xtended 9(.7) 99(.9) (.) (.9) SLHG--A- -/9 Lock Nut (.) Hex. (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. (9.) 6. (.). (6.6). (6.) For other dimensions, see "SLHG-- " drawing above. For other dimensions, see "SLHG--W" drawing left. 7
14 SLHG-- - -N-/9 Fully xtended (7.) Fully xtended 9. (7.) Tank Port "T" 6.7(.) 76. (.) Plug-in Connector Type Pressure Port "P" Pilot rain Port "Y" (For xternal rain Type only) Mounting Surface: ISO -AF---A.(.) ia. Through (.6) ia. Spotface 6 Places Pilot Pressure Port "X" (For xternal Pilot Type only). (.) C/R :.(.) AC : 96.(7.7) (.) C Cylinder Port "B" Cylinder Port "A" Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. 7 (.) (.).(.) (.77) Manual Actuator 6(.) ia. Mounting Surface (s Furnished) 6 (.) 6(.) ia. Two Locating Pins SLHG-- -A -N SLHG-- - -N SLHG-- -R -N imensions mm (Inches) C F 9 (.) 9 (.) (.9) (.9) 6 (.) 7. (.) 7. (.) 7. (.) (.) 79. (.). (6.) 9 (7.) C/R :.7(.) AC :.7(.) Cable eparture Cable Applicable: Outside ia mm (. -.9 in.) Conductor Area... Not xceeding. mm (. sq. in.) F 7 (.6) SLHG--- -N-/9. (.) 6. (.) 6. (.) Position of cable departure can be changed. For the details, refer to SLHG- valve on page 66. (.) 99 (.9) (.9). (.) SLHG---A -N SLHG--- -N SLHG---R -N imensions mm (Inches) (.9) 6 (.) 7. (.) 7. (.7). (.) 7. (.6) For other dimensions, see "SLHG-- - -N" drawing above. IMNSIONS IN MILLIMTRS (INCHS) 7
15 IRCTIONAL CONTROLS Plug-in Connector Type Mounting Surface: ISO -AF---A SLHG--W- -N-/9 SLHG--A- -N-/9 Fully xtended 9(.7) Fully xtended.(6.) Lock Nut (.) Hex. (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. (9.). (.) SLHG--W-A -N SLHG--W- -N SLHG--W-R -N imensions mm (Inches) (.9) 6 (.) 7. (.) 7. (.7). (.) 7. (.6) For other dimensions, see "SLHG--W- -N" drawing left. For other dimensions, see SLHG-- - -N on the previous page. SLHG--W- -N-/9 SLHG--A- -N-/9 Lock Nut (.) Hex. Fully xtended 9(.7) (.) 99 (.9) (.9) Fully xtended.(6.) (.) Hex. INC. Lock Nut 9(.7) Hex. 6(.) Hex. Soc. C. (9.) 6. (.) SLHG--W-A -N SLHG--W- -N SLHG--W-R -N imensions mm (Inches) (.9) 6 (.) 7. (.). (6.7) 9. (7.). (7.) For other dimensions, see "SLHG--W- -N" drawing left. For other dimensions, see SLHG-- - -N on the previous page. IMNSIONS IN MILLIMTRS (INCHS) 7
16 List of Seals for Main Valve, Pilot Selector Valve and Orifice SLHG-/6/- - -/9 Y Orifice for AT Orifice for PA Z Orifice for BT Orifice for PB Section Y-Y Y Z Section Z-Z SLHG-/6/-- -/9 6 Note) Main valve is same as above drawings. List of Seals for Main Valves Item Name of Parts Back Up Ring Orifice Type SLHG- SLHG-6 SLHG- Part Numbers SLHG- SLHG-6 SLHG- SO-NB-P SO-NB-P SO-NB-P9 SO-NA-P SO-NB-P SO-BB-P SO-NB-G SO-NB-P SO-NB-P SO-NA-P SO-NB-P9 SO-BB-P SO-NB-G SO-NB-P SO-NB-P SO-NA-P6 SO-NB-P SO-BB-P6 Qty. Note: When ordering the seals, please specify the seal kit number listed on page 7. Item Orifice The timing of flow path opening/closing can be adjusted as required by selecting the appropriate pilot orifice diameter. When the diameter of the orifice is to be changed, another orifice should be ordered. Standard built-in orifice diameters and selectable orifice diameters are listed in the table below. TP-OPT-/6 x d Orifice iameter "d" mm Standard Max. ia. at Pressure Selectable Built-in over MPa(9 PSI)..,.6,.,....,.,.6,...,.. Item Pilot Selector Valve List Multi-Purpose Valve SLHG-- SLHG-- SLHG-- SLHG-6- SLHG-6- SLHG-6- SLHG-- SLHG-- SLHG-- Pilot Selector Valve CG--- CG--- CG--- CG-6-- CG-6-- CG-6-- CG-6-- CG-6-- CG-6-- Note: For details of Pilot Selector Valve, see page 76. Pilot Valve Refer to page 7 for Pilot Valve. 7
17 IRCTIONAL CONTROLS List of Seals for Main Valves and Pilot Selector Valve SLHG-/6/-W- -/9 6 7 W Z Orifice for AT Orifice for PA Orifice for BT Orifice for PB Section W-W SLHG-/6/- A - -/9 A W Z Section Z-Z SLHG-/6/-W- -/9 6 List of Seals for Main Valves Item 9 6 Note : Name of Parts Back Up Ring The figures in ( A Part Numbers SLHG- SLHG-6 SLHG- SO-NB-P SO-NB-P SO-NB-P6 SO-NB-P SO-NB-P9 SO-NA-P SO-NB-P SO-BB-P SO-NB-G SO-NB-P SO-NB-P SO-NB-P SO-NB-P SO-NA-P SO-NB-P9 SO-BB-P Qty. SO-NB-G SO-NB-P SO-NB-P () SO-NB-A () SO-NB-P SO-NA-P6 () SO-NB-P SO-BB-P6 () ) indicate the quantity of seals used for A and Note : When ordering the seals, please specify the seal kit number listed on page 7. Pilot Valve Refer to page 7 for Pilot Valve. Note) Main valve is the same as above drawings. Pilot Selector Valve List Multi-Purpose Valve SLHG--A- SLHG--W- SLHG--A- SLHG--W- SLHG-6-A SLHG-6-W SLHG-6-A SLHG-6-W SLHG--A SLHG--W SLHG--A SLHG--W Pilot Selector Valve Item CG--A- - CG--W- - CG--A- - CG--W- - CG-6-A- CG-6-W- CG-6-A- CG-6-W- CG-6-A- CG-6-W- CG-6-A- CG-6-W- Item CG--- CG-6-- CG-6-- Note: Fill "B" or "H" representing the pressure adjustment range in section marked with. See page 77 for the details of the pilot selector valves. See the previous page for Item Orifice. 7
18 List of Seals (Pilot Selector Valves) CG-/6-- X X Section X-X CG-/6-- X X Section X-X CG-/6-- X X Section X-X List of Seals CG- CG-6 Item Name of Parts Part Numbers Quantity CG-- CG-- CG-- Part Nmbers Quantity CG-6- CG-6- CG SO-NB-P SO-NB-P SO-NB-P SO-NB-P 7 7 SO-NB-P SO-NB-P9 SO-NB-P SO-NB-A 7 7 Note: When ordering the o-rings, please specify the seal kit number listed in page 7. 76
19 IRCTIONAL CONTROLS List of Seals (Pilot Selector Valves) CG-/6-W- Y Section Y-Y 6 7 Y 6 6 CG-/6-A- CG-/6-A- 6 6 CG-/6-W- Y Y Section Y-Y Y Y List of Seals CG- CG-6 Item Name of Parts Part Numbers Quantity -W- -A- -W- -A- Part Nmbers Quantity -W- -A- -W- -A Back Up Ring SO-NB-P SO-NB-P9 SO-NB-P SO-NB-P SO-NA-P6 SO-NB-P SO-BB-P6 SO-NB-P6 SO-NB-P SO-NB-P SO-NB-P SO-NA-P9 SO-NB-P9 SO-BB-P9 Note: When ordering the seals, please specify the seal kit number listed in page 7. 77
20 List of Seal Kits and Pilot Valves SLHG SLHG SLHG SLHG SLHG SLHG SLHG--A- SLHG--A- SLHG--W- SLHG--W- SLHG--A- SLHG--A- SLHG--W- SLHG--W SLHG SLHG SLHG SLHG SLHG SLHG SLHG-6-A- - - SLHG-6-A SLHG-6-W- - - SLHG-6-W SLHG-6-A- - - SLHG-6-A SLHG-6-W- - - SLHG-6-W SLHG SLHG SLHG SLHG SLHG SLHG SLHG--A- - - SLHG--A SLHG--W- - - SLHG--W SLHG--A- - - SLHG--A SLHG--W- - - SLHG--W Pilot Valve SG--C SG--C SG--C SG--C SG--B SG--B SG--C SG--C SG--C SG--C SG--B SG--B SG--B SG--B SG--C SG--C SG--C SG--C SG--B SG--B SG--C SG--C SG--C SG--C SG--B SG--B SG--B SG--B SG--C SG--C SG--C SG--C SG--B SG--B SG--C SG--C SG--C SG--C SG--B SG--B SG--B SG--B Complete Kit KS-SLHG--- - KS-SLHG--- - KS-SLHG--- - KS-SLHG--A- - KS-SLHG--W- - KS-SLHG--A- - KS-SLHG--W- - KS-SLHG KS-SLHG KS-SLHG KS-SLHG-6-A- - KS-SLHG-6-W- - KS-SLHG-6-A- - KS-SLHG-6-W- - KS-SLHG--- - KS-SLHG--- - KS-SLHG--- - KS-SLHG--A- - KS-SLHG--W- - KS-SLHG--A- - KS-SLHG--W- - Seal Kit Numbers For Pilot Selector Valves KS-CG--- KS-CG--- KS-CG--A- KS-CG--W- KS-CG--A- KS-CG--W- KS-CG-6-- KS-CG-6-- KS-CG-6-- KS-CG-6-A- KS-CG-6-W- KS-CG-6-A- KS-CG-6-W- KS-CG-6-- KS-CG-6-- KS-CG-6-- KS-CG-6-A- KS-CG-6-W- KS-CG-6-A- KS-CG-6-W- For Pilot Valves KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) KS-SG-- -7 ( Set Req'd) Note : Fill coil type (a symbol representing current/voltage) in section marked. Likewise, in section marked, fill a symbol representing the type of electrical conduit connection (None: Terminal Box Type, N: Plug-in Connector Type). : A complete seal kit is composed of seal kit for pilot selector valve, seal kit for pilot valve and seal for main valve. See pages 7 and 7 for information on the seals for main valve. : See page for the detailed information on the pilot valves. 7
21 IRCTIONAL CONTROLS How to Change Pilot & rain Connection Pilot Connectio n and rain Connectio n can be changed easily with a disconnection/connectio n of pilot plug. The following drawings give illustrations of xternal Pilot-xternal rain Type, When changing to Internal Pilot-Internal rain Type, the following procedure may be followed. xternal Pilot Internal Pilot (See Section -) ) Remove pipe plug. ) Remove pipe plug. ) Wind a sealing tape around the pipe plug the port., then fit the plug into xternal rain Internal rain (See Section -) ) Remove pipe plug. ) Remove pipe plug. ) Wind a sealing tape around the pipe plug, then fit the plug into the port. ) In case of SLHG-, fit the plug into the port "Y" on the sub-plate. In case of SLHG-6/, wind a sealing tape around the plug and then thread it into the port "Y". SLHG- Pipe Plug Pipe Plug for rain Connection Selection Pipe Plug for Pilot Connection Selection Pipe Plug Section - Section - SLHG-6/ Pipe Plug for Pipe Plug for Pilot Connection rain Connection Selection Selection Pipe Plug Pipe Plug Thread "Y" Section - Section - 79
Poppet Type Directional Valves
IRCTIONAL CONTROLS Poppet Type irectional Valves Valve Type Graphic Symbols Max. Operating Pressure MPa (PSI) Maximum Flow U. S. GPM.5 5 5 5 5 5 L/min Page Poppet Type Solenoid Operated irectional Valves
More informationThrottle Modules / Throttle and Check Modules
FLOW CONTROLS Used as pilot choke valves for solenoid controlled pilot operated directional valves and pilot operated directional valves. Graphic Symbols Valve Size 3 Standard Type P AB T TCG- P A B T
More informationPilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves
FLOW CONTROLS Flow control of these valves is continuously made by a hydraulically operated pilot piston mechanism which controls opening area of the orifice of the valve. With the use of these valves,
More informationRestrictors / One Way Restrictors
FLOW CONTROLS This valve is used to regulate an actuator speed in a circuit where line pressure is almost steady and small fluctuation of oil flow due to pressure changes is permitted. Integrated check
More informationFLOW CONTROLS. Maximum Flow U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. Page. Valve Type.
FLOW CONTROLS Valve Type Graphic Symbols Maximum Operating Pressure MPa (PSI) Maximum Flow U.S.GPM 5 5 5 5 5 5 5 Page Flow Control Valves (5) 77 Flow Control and Check Valves (5) 77 Pilot Operated Flow
More informationFlow Control Valves / Flow Control and Check Valves
LOW CONTROLS These valves are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (viscosity of the fluid).
More informationSHUT-OFF TYPE SOLENOID OPERATED DIRECTIONAL VALVES DSPC/DSPG-01/03(1/8,
SHUT-OFF TYP SOLNOID OPRATD VALVS DSPC/DSPG-/(/8, /8) Cartridge Type / Mounting Up to 5 MPa (6 PSI), 8 (. U.S.GPM) Pub. C- The shut-off type solenoid operated directional valves are poppet type solenoid
More informationHydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.
Hydraulic Fluids Fluid Types Any type of hydraulic fluids listed in the table below can be used. Petroleum base oils Use fluids equivalent to ISO VG 32 or VG 46. Use phosphate ester or polyol ester fluid.
More informationProportional Electro-Hydraulic Pilot Relief Valves
Proportional Electro-Hydraulic This valve consists of a small DC solenoid and a direct-acting relief valve. It serves as a pilot valve for a low flow rate hydraulic system or a proportional electro-hydraulic
More informationDirect Operated Type Directional and Flow Control Valves
Specifications igh Response Type Proportional Electro-ydraulic Directional and Flow Control Valves igh response, high precision and high reliability are achieved be a combination of a compact and powerful
More informationPRESSURE REDUCING AND RELIEVING VALVES
REDUING AND RELIEVING VALVES RBG-3 / 6 (3/8, 3/4) Mounting Specifications / Model Number Designation / Others Up to 25 (363 ), 25 (33 U.S.GPM) reducing and relieving valves are composite pressure control
More informationPressure Reducing and Relieving Valves
reducing and relieving valves are composite pressure control valves having pressure reducing and counterbalancing functions developed for hydraulic balancing circuits. Specifications RBG-- * - * RBG-6-
More informationProportional Electro-Hydraulic Flow Control (and Check) Valves
Ω Proportional Electro-ydraulic Flow Control (and Check) Valves Since the preselected flow rate continuously varies in proportion to the current input to the valve, the system flow rate can be remotecontrolled
More informationMin. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.
Flow Control These are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (Viscosity of the fluid). They
More informationSeries Proportional Electro-Hydraulic Controls
Proportional Electro-ydraulic Controls Types Graphic Symbols Max. Operating Pressure () Maximum Flow U.S.GPM. 3 3 3 L/min Page Pilot Relief Valves. (3) EDG 67 Relief Valves. (3) EBG 3 6 676 Relieving and
More informationPRESSURE REDUCING AND RELIEVING VALVES
REDUING AND RELIEVING VALVES RBG-3 / 6 (3/8, 3/4) Mounting Specifications / Model Number Designation / Others Up to 5 (363 ), (33 U.S.GPM) reducing and relieving valves are composite pressure control valves
More information06 SERIES MODULAR VALVES. Pub. EC-1404
6 SERIES General Information Mounting Surface : ISO -AE-8--A, CETOP-8, NPA-D6 Up to 5 MPa (363 PSI), 5 L /m in (3 U.S.GPM) Pub. EC- The modular valves are functional elements with which a hydraulic system
More informationPROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS
H PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS -Hybrid Components...Page Proportional Electro-Hydraulic Control Valves...Page 7 Proportional Electro-Hydraulic Controls High-accuracy, simple, convenient realizes
More informationProportional Electro-Hydraulic Flow Control and Relief Valves
Ω Ω Proportional Electro-ydraulic Flow ontrol and Relief Valves This flow control and relief valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since
More informationMax. Operating Pressure Kgf/cm 2
In-Line Check Valves DIRCTIONAL CONTROLS These valves allow free flow in one direction and prevent flow in the reverse direction. Cracking pressure specified is the pressure required to open the valve
More informationMax. Reversed Free Flow. Max. Operating. Pressure MPa (PSI) Fine Feed 20 (5.3) 14 (2030) 40 (10.6) ( ) 40 (10.6) (
These valves are the combination of flow control valve, a deceleration valve and a check valve and used mainly for controlling rapid traverse and feed cycles machine tools. Switching from rapid traverse
More information" " Series Variable Displacement Piston Pumps
" " Series Variable Displacement Piston Pumps AR Axial Port Type AR Side Port Type "AR" series variable displacement pump has been developed which the aim of even further the quientness in operation, smaller
More informationUNLOADING RELIEF VALVES
UNLOADING RELIEF VALVES BUG-6/1 (3/4, 1-1/4) Specifications / Model Number Designation Up to 21 (35 ), L /min (66 ) Pub. E- These valves are used to operate the pumps with minimum load in accumulator circuits
More informationMax. Reversed Free Flow L/min
These Valves are the combination of flow control valve, a deceleration valve and a check valve and used mainly for controlling rapid traverse and feed cycle in machine tools. Switching from rapid traverse
More information"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22-FR01
"AR" SERIES Variable Displacement-Single Pumps Compensator Type, / AR-FR1 Up to 1 MPa ( PSI),. cm /rev ( CU.IN./rev) Pub. EC- A Compensator Valve Adj. Screw Spool Control Piston Drain Port Flow Adj. Screw
More informationSolenoid Controlled Relief Valves
hese valves are a comination of a pilot operated relief valve and a solenoid operated directional valve. Piping etween the two is eliminated as the solenoid valve is directly mounted on the relief valve
More informationProportional Electro-Hydraulic Directional and Flow Control Valves
Proportional Electro-Hydraulic s These valves are double-deck directional and flow control valves employing as their pilot the electro-hydraulic proportional pressure reducing valves with two proportional
More information"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22- FR01 3
"AR" SERIES Variable Displacement-Single Pumps Compensator Type,AR / AR- FR Up to MPa ( PSI),. cm /rev (.5 CU.IN./rev) Pub. EC- A Compensator Valve Adj. Screw Spool Control Piston Drain Port Flow Adj.
More information"A" Series Variable Displacement Piston Pumps Single Pump, Pressure Compensator Type
A"A" Series PISTON PUMPS Single Pump, Compensator Graphic Symbol M O Specifications Model s A-FRB- A-FRC/H- A- -R-- - -K- A- -R-- - -K- A- -R-- - -K- A- -R-- - -K- A- R S- A9- R S- A- R S- Geometric Displacement
More informationEH SERIES PROPORTIONAL ELECTRO-HYDRAULIC CONTROL VALVES
Pub. EC- E SERIES ELECTRO-YDRAULIC CONTROL VALVES Pilot Relief / Relief / Reducing and Relieving / Flow Control / Flow Control and Relief / Directional and Flow Control Up to. ( PSI), L/min (6 U.S.GPM)
More information10 SERIES MODULAR VALVES
General Information Mounting Surface : ISO 441-A-1-4-A, CETOP-1, NPA-D1 Up to 5 MPa (363 PSI), 8 L /min (11 U.S.GPM) Pub. EC-145 The modular valves are functional elements with which a hydraulic system
More informationEManually Operated Directional Valves
DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -
More informationEManually Operated Directional Valves
DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -
More informationE SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts
ydraulic Relief s The electro hydraulic relief valve is designed for compactness and high efficiency. The valve provides fast proportional response to the input current. For linear pressure control a special
More informationISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090
Spare Parts List PVR-* - * -RAA-4/4 PVR-* - * -RAA-4/4 PVR-* - * -RAA-/ PVR4-* - * -RAA-/ 4 5 4 6 8 8 6 5 4 Y Section Y-Y Y 6 5 Section - 8 Cartridge Kits Model Numbers PVR-6- * -RAA-4 * PVR-8- * -RAA-4
More information10 SERIES MODULAR VALVES. Pub. EC-1405
SERIES General Information Mounting Surface : ISO ----, CETOP-, NP-D Up to 5 MPa (363 PSI), 8 L /m in ( U.S.GPM) Pub. EC-5 The modular valves are functional elements with which a hydraulic system can be
More information"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE
"G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS
More informationProportional Electro-Hydraulic Relieving and Reducing Valves
These valves consist of a small size but high performance EH series electro-hydraulic proportional pilot relief valve and reducing valve with relief function. The valves control the system pressure proportionally
More informationRELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled
RELIEF VALVES Remote ontrol / Direct ype ilot Operated / Solenoid ontrolled Up to 5 Ma (3630 SI), 0 L /m in (06 U.S.GM) ub. E-00 Remote ontrol Relief Valves... age 3 his valve is used as a remote control
More information" " Series Variable Displacement Piston Pumps
" " Series Variable Displacement Piston Pumps Compensator Type Constant Power (Torque) Control Type Load Sensing Type Pump Type Graphic Symbol Geometric Displacement cu. in./rev...5 5 5 5 5 cm /rev Maximum
More information50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination
T,T,F SERIES Fixed Displacement-Single, Double, Combination Up to 7 MPa ( PSI), 9 cm /rev (. CU.IN./rev) Single Pumps These pumps are widely used as a source of hydraulic power. They combine stable performance
More informationBST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.
Specifications hreaded Connection Mounting BS-- - - - -47 BS-06- - - - -47 BS-0- - - - -47 BSG-- - - - -47 BSG-06- - - - -47 BSG-0- - - - -47 BS / BSG- / 06 / 0 hreaded Connections / Mounting Specifications
More informationA Series Variable Displacement Piston Pumps
A Series Variable Displacement Piston Pumps A37 A56 A1637 A16 A10 A Series Variable Displacement Piston Pumps Pump Type Graphic Symbol Geometric Displacement cm 3 /rev 1 5 10 0 50 100 00 300 Maximum Operating
More informationEMechanically Operated Directional Valves
E DIRECIONL CONROLS Cam Operated Directional Valves hese valves may be used to shift the direction of oil flow by depressing the spool by way of a cam. Specifications Max. Operating Max. -Line Max. Flow
More informationPROPORTIONAL ELECTRO-HYDRAULIC CONTROLS
H PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS Hydraulic Controls H-3 H-1 E Series Hydraulic Controls Hydraulic Controls Max. Maximum Flow Types KS Graphic Symbols Operating L/min 1 2 3 5 10 20 30 50 100 200
More informationHigh Pressure, High Flow Rate Modular Valves
High Pressure, High Modular Valves EIC-F-14- MODULR VLVES The modular valves are functional elements with which a hydraulic system can be composed and built easily by stacking them with the mounting bolts.
More informationModular Valves. Ratings
High Pressure, High Flow Rate Features Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly
More informationVent Connection. Pres. Adj. Range BT BG * ~ BG F- B T -03 P -V -32.
These valves protect the hydraulic system from excessive pressure, and can e used to maintain constant pressure in a hydraulic system. Remote control and unloading are permitted y vent circuit. PRESSURE
More informationVARIABLE DISPLACEMENT PISTON PUMPS
VRIBLE DISPLCEMENT Pump Type "R" Series Variable Displacement Piston Pumps Maximum Operating MPa (PSI) () Geometric Displacement cu. in./rev... cm /rev R R Catalogue No. Pub. EC- "" Series Variable Displacement
More informationE SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts
s The electro hydraulic relief valve is designed for compactness and high efficiency. The valve provides fast proportional response to the input current. For linear pressure control a special venting feature
More informationMODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.
F MODULES YUKEN's are stack type valves, and require no piping. They not only rationalise system build, but they also meet the technical requirements for a variety of hydraulic systems. Stacking systems
More information03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.
3 SERIES General Information Mounting Surface : ISO 44-C--4-, CETO-, N-DO Up to Ma (363 SI), 7 L /min (8. U.S.GM) ub. EC-43 MODULR VLVES The modular valves are functional elements with which a hydraulic
More information50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination 3
T,T,F SERIES Fixed Displacement-Single, Double, Combination Up to 7 MPa ( PSI), 9 cm /rev (. CU.IN./rev) Single Pumps These pumps are widely used as a source of hydraulic power. They combine stable performance
More informationLow Noise Type Solenoid Controlled Relief Valves
he low-noise solenoid controlled relief valve is a combination of a low-noise type pilot operated relief valve and a solenoid operated directional valve. It is used for no-load pump operation by using
More informationPROPORTIONAL ELECTRO-HYDRAULIC CONTROLS
H PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS Hydraulic Controls H-3 H-1 E Series Hydraulic Controls Hydraulic Controls Max. Maximum Flow Types KS Graphic Symbols Operating L/min 1 2 3 5 10 20 30 50 100 200
More informationSeries Shockless Type Solenoid Controlled Pilot Operated Directional Valves
Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating
More informationAR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps
Variable Displacement Piston Pumps AR Series Variable Displacement Piston Pumps Geometric Displacement Maximum cm 3 /rev Operating Pump Type Graphic Symbol Pressure Page 1 2 5 10 20 50 100 150 MPa Variable
More informationVANE PUMPS. Output Flow at 1200 r/min at No-Load U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols.
B VANE PUMPS Pump Type "PVR" Series Single Pumps Graphic Symbols at r/min at No-Load.. PVR PVR PVR PVR Maximum Operating MPa (PSI) () Page Fixed Displacedment "PVRA" Series Single Pumps "PVR" Series Double
More informationEHBG-03 EHBG-06 EHBG-10. Refer to Model No. Designation. 2% or Less(1%) 1% or Less *2. Refer to frequency Response on page V DC
Proportional Electro-ydraulic These valves, consist of a small size but high performance E series electro-hydraulic proportional pilot relief valve and a low noise type relief valve. The valves control
More information"A" Series Piston Pumps Variable Displacement-Single Pumps Electro-Hydraulic Proportional Pressure & Flow Control. Type
Variable Displacement-Single Pumps Electro-Hydraulic Proportional & Flow Type 6 / / 7 / 6 / 7 / 9 / Model Number Designation Safety valve Input Signal for Flow Input Signal for mplifier Proportional Solenoid
More informationMax. Operating Pressure Kgf/cm 2. F- YB T -01 -F Max. Operating Design Pressure Kgf/cm 2 Number. Panel. Mounting
Remote ontrol Relief Valves his valve is used as a remote control valve for pilot operated type pressure control valves. EI--1-0 Graphic Symbol Specifications hreaded onnection Designation F- YB -01 -F
More informationType C2 Seat Type Solenoid Pilot Valve
Type C Seat Type Solenoid Pilot Valve JIS graphic symbols for hydraulic system T eatures No hydraulic locking occurs even during long periods of pressurized operation Nomenclature 1 3 5 - - - - - 1 3 5
More informationProportional Electro-Hydraulic Flow Control (and Check) Valves
Proportional Electro-Hydraulic Flow Control (and Check) Valves EH SERIES The system flow rate can be controlled remotely as desired by regulating input voltage. Further, since pressure and temperature
More informationPilot Operated Check Valves
Pilot Operated heck Valves Nomenclature IS graphic symbols for hydraulic system L eatures - P - - - - pplicable fluid code No designation: Petroleum-based hydraulic fluid, waterglycol hydraulic fluid :
More informationHigh Pressure, High Flow Rate Modular Valves
eatures Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly and easily. roblems such
More informationDIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications
ilot Operated Directional s DIRECIONL CONROLS hese valves perform a change over of spool by hydraulic pilot and shift the direction of oil flow. EIC-E-04-0 Specifications Model Numbers Maximum Flow L/min.
More informationNote: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.
PRESSURE CONTROLS Fluid Types Any type of hydraulic fluids listed in the table below can be used Petroleum base oil Synthetic Fluids Water Containing Fluids Use equivalent to ISO VG32 or VG46. Use phosphate
More informationPressure Control Valves
efore using the product, please check the Pressure ontrol Valves JIS graphic symbols for hydraulic system Refer to the next page. Features These direct operated control valves can be used as sequence valves,
More informationModular Throttle Valve MST MT MTC MCT Solenoid Operated Throttle Valve Throttle Valve Throttle and Check Valve Counter Restrictors Valve
Modular Throttle MST MT MTC MCT Solenoid Operated Throttle Throttle Throttle and Check Counter Restrictors Modular Relief MGS MBR MCB MRB MSV MRV Two Section Reducing Reducing Counter Balance Balance Sequence
More informationA Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics.
EIC--12- PISTON PUMPS Series Variable Features High efficiency Under the conditions of pressure 16 Kgf/cm² and speed 18 r/min. volumetric efficiency is over 98% and the overall efficiency is over 9%. Low
More informationHigh Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves
igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct
More informationThese valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8
DIRCINL CNRLS Manually perated Directional s hese valves may be used to manually shift the spool position and change the direction of oil flow. IC--1005-0 Specifications Numbers DMG-01-C -10 DMG-01-D -10
More information"PV11R" SERIES Fixed Displacement- Single PV11R10/PV11R20
"PVR" SERIES Fixed Displacement- Single PVR/PVR Up to MPa ( ),. cm /rev (. CU.IN./rev) Pub. EC- These pumps are of completely unique design for extra high pressure applications. The excessive wear to the
More informationDIRECTIONAL CONTROLS
E DIRECTIONAL CONTROLS Solenoid Operated Directional Valves E-5 Solenoid Controlled Pilot Operated Directional Valves E-5 Pilot Mechanically Operated Directional Valves E-5 Check/Pilot Controlled Check
More information01 SERIES MODULAR VALVES. Pub. EC-1402
SERIES General Information Mounting Surface : ISO --3--, CEO-3, N-D Up to 3.5 Ma (57 SI), 35 L /m in (9.5 U.S.GM) ub. EC- MODULR VLVES he modular valves are functional elements with which a hydraulic system
More informationOBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006
NO. 10 01E September 1, 2010 Public Relations Group Products Publicity Section Sales Administration Department Hamamatsucho Seiwa Bdg., 4-8, Shibadaimon 1-chome, Minato-ku, Tokyo 105-0012, Japan Tel: +81-3-3432-2113
More informationPROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]
J PROPORTIONAL VALVES SERVO VALVES J Model [Model No.] Solenoid pilot operated proportional relief valve [JRP] Solenoid operated proportional relief valve [JRPL] Type C2 solenoid operated proportional
More information04 Series Modular Valves Release of New Series
NO. 11 05E September 5, 2011 Public Relations Group Products Publicity Section Sales Administration Department Hamamatsucho Seiwa Bdg., 4-8, Shibadaimon 1-chome, Minato-ku, Tokyo 105-0012, Japan Tel: +81-3-3432-2113
More informationDIRECTIONAL CONTROL (LD) DIRECTIONAL AND FLOW CONTROL (LD) SOLENOID OPERATED DIRECTIONAL
Pu. EC-01 DIRECTIONL CONTROL (LD) DIRECTIONL ND FLOW CONTROL (LD) SOLENOID OPERTED DIRECTIONL CONTROL (LDS) RELIEF (L) / SOLENOID CONTROLLED RELIEF (LS) VLVES Up to 31.5 MPa (4570 PSI), 5500 L / min (1453
More informationISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description
Vickers SystemStak SystemStak Valves ISO 441 size 7; 315 bar (45 psi); up to 2 L/min (53 USgpm) General Description This range of stackable hydraulic controls are designed to be mounted under a size 7
More informationVickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)
Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................
More informationAR Series Variable Displacement Piston Pumps. [Comparison of AR16 with A16 ] A16,32 Design 188. AR16,22 Design 130. Ratio of Mass (AR16/A16) 74%
PISTON PUMPS EIC--11- Features Smaller in Size and Lighter in Mass s indicated in the dimensional comparison presented below, the R1 is smaller than the 1(3 design). lso, the mass of R1 is substantially
More informationReducing Valve/Reducing Valve with Check Valve
Reducing Valve/Reducing Valve with Check Valve Nomenclature JIS graphic symbols for hydraulic system JGB JGBC Features - JGB - - - Applicable fluid code No designation: Petroleum-based hydraulic fluid,
More informationDiscrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8
G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications
More informationDiscrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B
G31/41 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 Refer to nding 17 for more details. JIS symbol G31/41: Universal
More informationCoolant Valve. VNC Series. Cylinder actuation by pilot air
oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,
More informationSolenoid Pilot Operated Proportional Directional Control Valve
Solenoid Pilot Operated Proportional Directional Control Valve Features hese solenoid pilot operated proportional directional control valves use a nozzle flapper valve as pilot valve and perform spool
More informationDirectional Controls
VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................
More informationPressure Relief Valves
VICKERS Pressure Relief Valves Unloading Relief Valves EURG1/2-06/10, 13 Design and EURT1/2-06/10, 12 Design Sectional Illustrations EURG* EURT* Basic Characteristics Mounting... Pipe or subplate mounting
More informationStandard Hydraulic Power Units Power Packages
K Standard Hydraulic Power Units Power Packages Energy-Saving Hydraulic Units and Controllers Energy-Saving Control System for Hydraulic Units (Energy-Saving Controller) Equipped with the variable displacement
More informationPressure Control Valves. General Description. Specifications. Ordering Information
Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure
More informationProportional Valves. Proportional solenoid valves for pressure and flow control
Proportional Valves Proportional solenoid valves for pressure and flow control EATON Vickers Screw-In Cartridge Valves V-VLOV-MC-E4 September, 7 - Electro- Proportional Valves Section Contents Typical
More informationDirectional Control Valve Series 4D01 (DENISON)
Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift
More informationDiscrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type
31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications
More informationCoolant Valve. Air Operated/External Pilot Solenoid
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page
More informationVariable Displacement Piston Pumps
A3HG Series High Pressure Variable Displacement Piston Pumps A3HG71 A3HG1 A3HG Through Drive A3HG Series High Pressure Variable Displacement Piston Pumps Pump Type Graphic Symbol Geometric Displacement
More informationPISTON PUMPS. A3H Series High Pressure Variable Displacement Piston Pumps. Features. A3H Series Variable Displacement Piston Pumps.
3H Series High Variable EIC--13- Features 1 Control System for Wide Range pplication: 1 Compensator Type 3H Series High Variable 9 Constant Power Control Type 1 Load Sensing Type For these controls system,
More informationHYDRAULIC CYLINDER CJT TYPE SERIES HYDRAULIC CYLINDER CJT SERIES HYDRAULIC CYLINDER WITH PROXIMITY SWITH C6 SERIES COMPACT CYLINDER J-1
J HYDRAULIC CYLINDER CJT TYPE 35 70 40 20 SERIES HYDRAULIC CYLINDER CJT SERIES HYDRAULIC CYLINDER WITH PROXIMITY SWITH C6 SERIES COMPACT CYLINDER J-4 J-45 J-5 J- Related to the unit and the design number
More informationRA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)
R 26 892/06.98 Pressure Reducing Valve, Pilot Operated Model DR (Series 5) Size 10 to 0... 5000 PSI (50 bar)... 105 GPM (400 L/min) R 26 892/06.98 Replaces: 05.94 Pilot operated pressure reducing valve
More informationDIRECTIONAL CONTROL VALVES CETOP3
DIRECTIONAL CONTROL VALVES CETOP3 GENERAL DESCRIPTION RH0...1-...F... Document: DCVC3-1-Aug 2013 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction RH0...1-...F...
More information